HomeMy WebLinkAboutWQ0041463_Application (FTSE)_20210423°{Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources APR 0 5 2021 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION WQROS LAYETTEVI LE � I��..ra�. REGIQNALOFFiCE This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been certified by a professional engineer and the applicant that the project meets the requirements of 15A NCAC 02T and the Division's Minimum Design Criteria and that plans, specifications and supporting documents have been prepared in accordance with, 15A NCAC 02T, 15A NCAC 02T .0300, Division policies and good engineering practices. PECE1VED DEQIDtNR While no upfront engineering design documents are required for submittal, in accordance with 15A NCAC 02T 0305(b), design documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design calculations, and project specifications referenced in 15A NCAC 02T .0305 and the applicable minimum design criteria. These documents shall be available upon request by the Division. Projects that are deemed permitted (do not require a permit from the Division) are explained in 15A NCAC 02T.0303. Projects not eligible for review via the fast track process (must be submitted for full technical review): > Projects that require an environmental assessment in accordance with 15A NCAC 1C .0100; > Projects that do not meet any part of the minimum design criteria (MDC) document; > Projects that involve a variance from the requirements of 15A NCAC 2T; > Pressure sewer systems utilizing septic tank -effluent pumps (STEPs) or simplex grinder pumps; ➢ STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains); > Vacuum sewer systems. General — When submitting an application, please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. Failure to submit all required items will necessitate additional processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy of Application and Supporting Documents ® Required unless otherwise noted B. Cover Letter (Required for All Application Packages): ® List all items included in the application package, as well as a brief description of the requested permitting action. ➢ Be specific as to the system type, number of homes served, flow allocation required, etc. ➢ If necessary for clarity, include attachments to the application form. C. Application Fee (All New and Major Modification Application Packages): El Submit a check or money order in the amount of $480.00 dated within 90 days of application submittal. ➢ Payable to North Carolina Department of Environmental Quality (NCDEQ) D. Fast Track (Form: FTA 04-16) Application (Required for All Application Packages): ® Submit the completed and appropriately executed application. > If necessary for clarity or due to space restrictions, attachments to the application may be made. ❑ If the Applicant Type in Item I.2 is a corporation or company, provide documentation it is registered for business with the North Carolina Secretary of State. ❑ If the Applicant Type in Item I.2 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of Deeds in the county of business. ® The Project Name in Item II.1 shall be consistent with the project name on the flow acceptance letters, agreements, etc. ® The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina licensed Professional Engineer. ® The Applicant's Certification on Page 5 of the application shall be signed in accordance with 15A NCAC 02T .0106(b). Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .0106(b). INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 1 of 3 E. Flow Tracking/Acceptance Form (Form: FTSE 04-16) (If Applicable): ® Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility. > Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different. > The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one year prior to the application date. > Submittal of this application and form FTSE indicates that owner has adequate capacity and will not violate G.S. 143- 215.67(a). > Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE. F. Site Maps (All Application Packages): ® Submit an 8.5-inch x 11-inch color copy of a USGS Topographic Map of sufficient scale to identify the entire project area and closest surface waters. > Location of the project (gravity sewer, pump stations & force main) > Downstream connection points and permit number (if known) for the receiving sewer • Include a street level map (aerial) showing general project area so that Division staff can easily locate it in the field. G. Existing Permit (All Modification Packages): ® Submit the most recently issued existing permit. ® Provide a list of any items within the permit the Applicant would like the Division to address during the permit modification (i.e., permit description, flow allocation, treatment facility, etc.). H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station): ❑ Per 15A NCAC 02T .0305(h)(1), submit documentation of power reliability for pumping stations. > This alternative is only available for average daily flows less than 15,000 gallons per day > It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0106(b)) or proposed contractor, stating that "the portable power generation unit or portable, independently -powered pumping units, associated appurtenances and personnel are available for distribution and operation of this pump station." > If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. (Required at time of certification) I. Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities): ❑ Per 15A NCAC 02T .0115(a)(1) provide the Certificate of Public Convenience and Necessity from the North Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the sewer extension, or ❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. J. Operational Agreements (Applications from HOA/POA and Developers for lots to be sold): ❑ Home/Property Owners' Associations ❑ Per l 5A NCAC 02T .0115(c), submit the properly executed Operational Agreement (FORM: HOA). ❑ Per 15A NCAC 02T .0115(c), submit a copy of the Articles of Incorporation, Declarations and By-laws. ❑ Developers of lots to be sold ❑ Per 15A NCAC 02T .0115(b), submit the properly executed Operational Agreement (FORM: DEV). For more information, visit the Division's collection systems website INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 2 of 3 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Swannanoa, North Carolina 28778 (828) 296-4500 (828) 299-7043 Fax Avery, Buncombe, Burke, Caldwell, Cherokee, Clay, Graham, Haywood, Henderson, Jackson, Macon, Madison, McDowell, Mitchell, Polk, Rutherford, Swain, Transylvania, Yancey Water Quality Section Fayetteville Regional Office 225 Green Street Suite 714 Fayetteville, North Carolina 28301-5094 (910) 433-3300 (910) 486-0707 Fax Anson, Bladen, Cumberland, Harnett, Hoke, Montgomery, Moore, Robeson, Richmond, Sampson, Scotland Water Quality Section Mooresville Regional Office 610 E. Center Avenue Mooresville, North Carolina 28115 (704) 663-1699 (704) 663-6040 Fax Alexander, Cabarrus, Catawba, Cleveland, Gaston, Iredell, Lincoln, Mecklenburg, Rowan, Stanly, Union Water Quality Section Raleigh Regional Office 1628 Mail Service Center Raleigh, North Carolina 27699-1628 (919) 791-4200 (919) 788-7159 Fax Chatham, Durham, Edgecombe, Franklin, Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Wake, Warren, Wilson Water Quality Section Washington Regional Office 943 Washington Square Mall Washington, North Carolina 27889 (252) 946-6481 (252) 975-3716 Fax Beaufort, Bertie, Camden, Chowan, Craven, Currituck, Dare, Gates, Greene, Hertford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne Water Quality Section Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, North Carolina 28405 (910) 796-7215 (910) 350-2004 Fax Brunswick, Carteret, Columbus, Duplin, New Hanover, Onslow, Pender Water Quality Section Winston-Salem Regional Office 450 W. Hanes Mill Road Suite 300 Winston-Salem, North Carolina 27105 (336) 776-9800 Alamance, Alleghany, Ashe, Caswell, Davidson, Davie, Forsyth, Guilford, Rockingham, Randolph, Stokes, Surry, Watauga, Wilkes, Yadkin Water Quality Section INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page 3 of 3 9 Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: WQOO l ty (03 1 " (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: City of Laurinburg (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: Charles D. Nichols III per 15A NCAC 02T .0106(b) Title: City Manager 4. Applicant's mailing address: Post Office Box 249 City: Laurinburg State: NC Zip: 28353-3719 5. Applicant's contact information: Phone number: (910) 276-8324 Email Address: cnichols@laurinburg.org II. PROJECT INFORMATION: 1. Project name: Pump Station Renovations (PS 8, 12, 13) 2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project If a modification, provide the existing permit number: WQ0041463 and issued date: February 5, 2020 If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Scotland 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.737107° Longitude: -79.506039° 5. Parcel ID (if applicable): (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: James C. Stowe, PE Firm: Willis Engineers Mailing address: 10700 Sikes Place, Suite 115 City: Charlotte State: NC Zip: 28277-8159 Phone number: (704) 338-4671 Email Address: jim@willisengineers.com License Number: 32639 IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Leith Creek WWTP Permit Number: NC0020656 Owner Name: City of Laurinburg V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes No ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Residential Leased ❑ Retail with food preparation/service ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Food and drink facilities ❑ Church ❑ Businesses / offices / factories ❑ Nursing Home ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool /Clubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) >Is there a Pretreatment Program in effect? ❑ Yes ® No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ® No > If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow a,b No. of Units Flow N/A N/A gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 0 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114) > Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ® Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material N/A N/A N/A > Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria > Section III contains information related to minimum slopes for gravity sewer(s) > Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pumn Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Pump Station 8 2. Approximate Coordinates (Decimal Degrees): Latitude: 34.745767° Longitude: -79.515032° 3. Design flow of the pump station: 0.0403 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 43 gallons per minute at 105 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material N/A N/A N/A 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_ > Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day > Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): > It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. > If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material N/A N/A N/A > Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria > Section III contains information related to minimum slopes for gravity sewer(s) > Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Pump Station 12 2. Approximate Coordinates (Decimal Degrees): Latitude: 34.745173° Longitude: -79.492375° 3. Design flow of the pump station: 0.0446 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 87 gallons per minute at 61 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material N/A N/A N/A 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_ > Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day > Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): > It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. > If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material N/A N/A N/A > Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria > Section III contains information related to minimum slopes for gravity sewer(s) > Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Pump Station 13 2. Approximate Coordinates (Decimal Degrees): Latitude: 34.714980° Longitude: -79.503863° 3. Design flow of the pump station: 0.0158 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 43 gallons per minute at 105 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material N/A N/A N/A 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): > Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day > Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): > It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. > If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (g) ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches > 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. > **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage > If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ® N/A > See the Division's draft separation requirements for situations where separation cannot be meet > No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per I5A NCAC 02B .0200? ❑ Yes ❑ No ® N/A > This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? > Information can be obtained from the 401 & Buffer Permitting Branch ® Yes ❑ No 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Desi.en Criteria for the Permitting of Pump Stations and Force Mains (latest version). and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? Yes No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: I, James C. Stowe, PE attest that this application for (Professional Engineer's name from Application Item III.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $1.0,000, as well as civil penalties up to $25,000 per violation. 30 Ma2021 ►ti1r"il,���� North Carolina Professional Engineer's seal, signature, and date: �`�-(N CARD ,''•, %=O .FESS/Q; .• SEAL 32639 �'•NG I NE�e''y� til�cs•. .5-Q``'%\ 3. Applicant's Certification per 15A NCAC 02T .0106(b): � / v 7/'4xrfe s Pew" iL h '; �,? � 0....44 HAI.4,a),e- attest that this application for (Signature Authority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 1 43-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: '! - '2,C3 2 1' FORM: FTA 04-16 Page 5 of 5 uf ~der Resoe g State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: City of Laurinburg - PS 8 Project Name for which flow is being requested: Pump Station Renovations (PS 8, 12, 13) More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Leith Creek WWTP b. WWTP Facility Permit #: NC0020656 All flows are in MGD c. WWTP facility's permitted flow 4.0 d. Estimated obligated flow not yet tributary to the WWTP 1.22 e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used 1.70 0.0 2.92 73% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: Pump Pump Station Station Firm (Name or Permit Capacity, * Number) No. MGD (A) Design Average Daily Flow** (Firm / pf), MGD 7 N/A 0.249 0.100 5b N/A 0.598 19 N/A 1.932 (B) (C) (D)=(B+C) (E)=(A-D) Obligated, Approx. Not Yet Current Tributary Avg. Daily Daily Flow, Flow, MGD MGD 0.034 0 0.239 0.087 0 0.773 0.430 0 Total Current Flow Plus Obligated Available Flow Capacity*** 0.034 0.066 0.087 0.152 0.430 0.343 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): N/A Downstream Permit Number: N/A Page 1 of 6 FTSE 10-18 State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: City of Laurinburg - PS 12 Project Name for which flow is being requested: Pump Station Renovations (PS 8, 12, 13) More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Leith Creek WWTP b. WWTP Facility Permit #: NC0020656 All flows are in MGD c. WWTP facility's permitted flow 4.0 d. Estimated obligated flow not yet tributary to the WWTP 1.22 e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used 1.70 0.0 2.92 73% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** 19 N/A 1.932 0.773 0.430 0 0.430 0.343 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): N/A Downstream Permit Number: N/A Page 1 of 6 FTSE 10-18 Dk ioft er Resoart.e:, State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: City of Laurinburg - PS 13 Project Name for which flow is being requested: Pump Station Renovations (PS 8, 12, 13) More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Leith Creek WWTP b. WWTP Facility Permit #: NC0020656 All flows are in MGD c. WWTP facility's permitted flow 4.0 d. Estimated obligated flow not yet tributary to the WWTP 1.22 e. WWTP facility's actual avg. flow 1.70 f. Total flow for this specific request 0.0 g. Total actual and obligated flows to the facility 2.92 h. Percent of permitted flow used 73% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pf), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** 14 N/A 0.230 0.092 0.056 0 0.056 0.036 19 N/A 1.932 0.773 0.430 0 0.430 0.343 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): N/A Downstream Permit Number: N/A Page 1 of 6 FTSE 10-18 III. Certification Statement: I Charles D. Nichols, III certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. igning Official Signature Date fir.. cu,er Title ofigning Official Page 2 of 6 FTSE 10-18 WOODRUN DR. PUMP STATION (PS NO. 7) rn o4 COBLE DR. } PUMP STATION J - (PS NO. 8) BLUE RM R NTCLAIR DR PURCELL RD. PUMP STATION (PS NO. 5B) O .. BLUE FARM RD. ,a 4, PUMP STATION ,,.. (PS N0. 12) 10 co LILY RD ` 10 ‘ 0 t ygwR, TURNPIKE RD. PUMP STATION PLC T'TION RD (PS NO. 14) ENGINEERS January 2020 ELM AVE. PUMP STATION (PS NO. 19) City of Laurinburg Street Map Scale: 1 "=4,000' LEITH CREEK WWTP ENZIE RD "FL JERUSALEM R LAUoRIURG WOODRUN DR. PUMP STATION (PS NO. 7) COBLE DR. PUMP STATION (PS NO. 8) uuillis ENGINEERS January 2020 PURCELL RD. PUMP STATION (PS NO. 5B) TURNPIKE RD. PUMP STATION (PS NO. 14) PLANTATION RD. PUMP STATION (PS NO. 13) LAURINBURG BLUE FARM RD. PUMP STATION (PS NO. 12) ELM AVE. PUMP STATION (PS NO. 19) City of Laurinburg USGS Topo Map Scale: 1 "=4,000' LEITH CREEK WWTP Copyright:c.2013'National Geographic Society, i-cubed, 441g. LAURINBURG ROY COOPER Governor MICHAEL S. REGAN Secretary S. DANIEL SMITH Director Charles D. Nichols, III City of Laurinburg PO Box 249 Laurinburg, NC 28353-3719 NORTH CAROLINA Environmental Quality February 5, 2020 Subject: Permit No. WQ0041463 City of Laurinburg Pump Station Renovations (PS 8, 12, 13) Wastewater Collection System Extension Permit Scotland County Dear Mr. Nichols: In accordance with your application received February 5, 2020, we are forwarding herewith Permit No. WQ0041463 dated February 5, 2020 to the City of Laurinburg for the construction and operation upon certification of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition II.1: This permit shall not be automatically transferable; a request must be made and approved. Condition II.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system- wide collection system permit issued to the Permittee. It shall be responsibility of the Permittee to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. North Carolina Department of Environmental Quality ( Division of Water Resources Fayetteville Regional Office 225 Green Street, Suite 714 I Fayetteville, North Carolina 28301 910,433,3300 An Equal Opportunity \ Affirmative Action Employer - Made in part by recycled paper City of Laurinburg Permit No. WQ0041463 If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Stephanie Zorio at (910) 433-3322 or via e-mail at stephanie.zorio@ncdenr.gov. Sincerely, —DocuSigned by: —5189C2D3DD5C42B... Trent Allen, Regional Supervisor Water Quality Regional Operations Section Fayetteville Regional Office Division of Water Resources, NCDEQ cc: James C. Stowe, PE, Willis Engineers, 10700 Sikes Place, Suite 115, Charlotte, NC 28277- 8159 Laserfiche File Page 2 of 9 STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENTAL QUALITY WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Laurinburg Scotland County for the construction and operation of approximately 35 GPM @ 82 TDH; 87 GPM @ 61 TDH and 33 GPM @ 83 TDH with a permanent generator w/ATS to serve as part of the Pump Station Renovations (PS 8, 12, 13) project, and the discharge of 0 gallons per day of collected domestic wastewater into the Leith Creek Wastewater Treatment Plant existing sewerage system, pursuant to the application received February 5, 2020, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the specified conditions and limitations contained therein. Do�cuS,iggnnedby: L2°iaa��uiuD5t,y16... Trent Allen, Regional Supervisor Division of Water Resources, NCDEQ By Authority of The Environmental Management Commission Permit Number: WQ0041463 Permit Issued: February 5, 2020 Page 3 of 9 SUPPLEMENT TO PERMIT COVER SHEET City of Laurinburg is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension. The sewage and wastewater collected by this system shall be treated in the Moore County Water Pollution Control Plant in accordance with Permit Number NC0020656. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. II. STANDARD CONDITIONS 1. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. [15A NCAC 02T.0104; G.S 143- 215.1(d3)] 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. [15A NCAC 02T.0110] 3. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. [15A NCAC 02T .0110] 4. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met: [15A NCAC 02T .0108(b)]: Page 4 of 9 a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: 1. For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi-annual distribution of grease education materials to users of the collection system by the permittee or its representative. 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. i. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. j. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system. 5. The Permittee shall report by telephone to a water resources staff member at the Fayetteville Regional Office, telephone number (910) 433-3300, as soon as possible, but in no case more than 24 hours, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any SSO and/or spill over 1,000 gallons; or Page 5 of 9 c. Any SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. [G.S. 143-215.1C(a1)] 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. [15A NCAC 02T.0108(b)] 7. Upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation, Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force mains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting applicable design calculations including pipe and pump sizing, velocity, pump cycle times, and level control settings, pump station buoyancy, wet well storage, surge protection, detention time in the wet well, and force main, ability to flush low points in force mains with a pump cycle, and downstream sewer capacity analysis. If a portable power source or pump is dedicated to multiple stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, include travel timeframes, shall be provided. c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non-compliance with this permit (including pipe length increases of 10% or greater, Page 6 of 9 increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit. Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After - construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. 115A NCAC 02T .0116] 8. Gravity sewers installed greater than ten percent below the minimum required slope per the Division's Gravity Sewer Minimum Design Criteria shall not be acceptable and shall not be certified until corrected. If there is an unforeseen obstacle in the field where all viable solutions have been examined, a slope variance can be requested from the Division with firm supporting documentation. This shall be done through a permit modification with fee. Such variance requests will be evaluated on a case -by -case basis. Resolution of such request shall be evident prior to completing and submitting the construction certification. [ 15A NCAC 02T.0105(n)] 9. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. [15A NCAC 02T .0116] 10. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12,1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. [15A NCAC 02T .0104; 15A NCAC 02T .0108(b-c)] 11. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. [15A NCAC 02T .0110; 15A NCAC 02T .0108(b)] 12. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by the Division any other Federal, State, or Local government agencies which have jurisdiction or obtaining other permits which may be required by the Division or any other Federal, State, of Local government agencies. [G.S. 143-215.1(b)] Page 7 of 9 CERTIFICATION CHECKLIST To be completed by the certifying engineer prior to operation of the permitted sewers, per 15A NCAC 02T.0116. Certifying Engineer: Certification Review Date: Project Name: WQ00 Project County: 1) Has permittee information changed since the permit was issued (or last modified): change of mailing address, change of ownership, transfer from developer to HOA/POA, etc. n Yes ❑ No • If yes, please provide either a change of ownership form or new contact information. Note that transfer of permits from the developer to the HOA/POA must occur with the first certification. 2) Have the as -built drawings have been signed, sealed, and dated by an N.C. PE? n Yes n No 3) Final Engineering certification? n Yes n No • If Partial Engineering certification, provide detailed narrative including what is being certified in the current phase, what was previously certified (if applicable), and what is left to be certified. 4) Adequate information related to sewer lines: n Yes n No n N/A • Three feet minimum cover has been provided for all sewers unless ferrous pipe was installed. • Minimum diameters for gravity sewers are 8-inches for public lines and 6-inches for private lines. • Manholes have been installed: At the end of each line, at all changes in grade, size, or alignment, at all intersections, and at distances not greater than 425 feet; minimum diameter shall be 4 feet (48-inches). 5) Adequate information related to pump stations: n Yes ❑ No n N/A • Ensure power reliability option was selected per 15A NCAC 02T.0305(h). 6) Was project construction completed in accordance with all of the following: n Yes ❑ No n N/A • 15A NCAC 02T, Minimum Design Criteria (MDC) for the permitting of Gravity Sewers (latest version), and MDC for the Permitting of Pump Stations and Force Mains (latest version)? If not, a variance approval is required in accordance with 15A NCAC 02T.0105(b), prior to certification and operation. • Contact the Central Office to discuss the variance to determine a course of action. • Applicant must submit two copies of the variance request form, plans, specifications, calculations, and any other pertinent information to the Central Office (one hard copy, one digital copy). • The central office will review the variance request, and if approvable, specific language regarding the variance will be incorporated into the permit, either via a special condition or a supplementary letter. A copy of the reissued permit with variance language or the variance letter must be maintained with the original documents. 7) Does the project contains high priority lines (15A NCAC 02T .0402(2))? ❑ Yes ❑ No • If yes, ensure that the permit already contains the necessary condition related to high priority lines 15A NCAC 02T.0403 (a) (5). If the permit does not include this language, the Fast Track reviewer will reissue the permit with the appropriate language. 8) Are Permit modifications are required for any changes resulting in non-compliance with this permit (including but not limited to pipe length changes of 10% or greater, change in flow, pump station design capacity design change of 5% or greater, and/or change in the number/type of connections)? n Yes n No • If yes, a permit modification request must be submitted to the appropriate Regional Office, and a modified permit with revised certification must be issued prior to certification and operation. NC DWR — Water Quality Regional Operations Section 225 Green St, Fayetteville, NC Zip 28301 Fayetteville Regional Office Phone: (910)-433-3300 FAX: (910)-486-0707 PERMITTEE: City of Laurinburg PERMIT #: WQ0041463 PROJECT: Pump Station Renovations (PS 8, 12, 13) ISSUE DATE: February 5, 2020 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature Date ENGINEERS CERTIFICATION I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe ( periodically, 1 weekly, full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: Final Partial (include description) Certification Comments/Qualifiers (attach if necessary): iniiHis ENGINEERS March 31, 2021 1973.037 (34) Ms. Stephanie Zorio NCDEQ— Division of Water Resources Fayetteville Regional Office 225 Green Street, Suite 714 Fayetteville, North Carolina 28301 Subject: Permit No. WQ0041463 City of Laurinburg Pump Station Renovations (PS 8, 12, 13) Final Certification Dear Ms. Zorio: This letter is to verify that construction of the subject project has been completed in substantial compliance and intent of the plans and specifications approved under Division of Water Resources permit number WQ0041463 dated February 5, 2020. Please find attached the original, executed "Engineer's Certification" and supporting documents. If you have any questions or need any additional information, please let me know. Yours very truly, WILLIS ENGINEERS Jim C. Stowe, PE Enclosures cc w/Enclosures: Mr. Dixon Medlin, City of Laurinburg Mr. Charles D. Nichols, III, City of Laurinburg 10700 Sikes Place, Suite 115 Charlotte, North Carolina 28277 704.377.9844 / NC License F-0114 CERTIFICATION CHECKLIST To be completed by the certifying engineer prior to operation of the permitted sewers, per 15A NCAC 02T.0116. Certifying Engineer: James C. Stowe, PE Certification Review Date: March 30, 2021 Project Name: WQ00 41463 Pump Station Renovations (PS 8,12, 13) Project County: Scotland 1) Has permittee information changed since the permit was issued (or last modified): change of mailing address, change of ownership, transfer from developer to HOA/POA, etc. n Yes n No • If yes, please provide either a change of ownership form or new contact information. Note that transfer of permits from the developer to the HOA/POA must occur with the first certification. 2) Have the as -built drawings have been signed, sealed, and dated by an N.C. PE? n Yes n No 3) Final Engineering certification? n Yes n No • If Partial Engineering certification, provide detailed narrative including what is being certified in the current phase, what was previously certified (if applicable), and what is left to be certified. 4) Adequate information related to sewer lines: n Yes ❑ No n N/A • Three feet minimum cover has been provided for all sewers unless ferrous pipe was installed. • Minimum diameters for gravity sewers are 8-inches for public lines and 6-inches for private lines. • Manholes have been installed: At the end of each line, at all changes in grade, size, or alignment, at all intersections, and at distances not greater than 425 feet; minimum diameter shall be 4 feet (48-inches). 5) Adequate information related to pump stations: ❑X Yes ❑ No n N/A • Ensure power reliability option was selected per 15A NCAC 02T.0305(h). 6) Was project construction completed in accordance with all of the following: [X- Yes ❑ No ❑ N/A • 15A NCAC 02T, Minimum Design Criteria (MDC) for the permitting of Gravity Sewers (latest version), and MDC for the Permitting of Pump Stations and Force Mains (latest version)? If not, a variance approval is required in accordance with 15A NCAC 02T.0105(b), prior to certification and operation. • Contact the Central Office to discuss the variance to determine a course of action. • Applicant must submit two copies of the variance request form, plans, specifications, calculations, and any other pertinent information to the Central Office (one hard copy, one digital copy). • The central office will review the variance request, and if approvable, specific language regarding the variance will be incorporated into the permit, either via a special condition or a supplementary letter. A copy of the reissued permit with variance language or the variance letter must be maintained with the original documents. 7) Does the project contains high priority lines (15A NCAC 02T .0402(2))? ❑ Yes X❑ No • If yes, ensure that the permit already contains the necessary condition related to high priority lines 15A NCAC 02T.0403 (a) (5). If the permit does not include this language, the Fast Track reviewer will reissue the permit with the appropriate language. 8) Are Permit modifications are required for any changes resulting in non-compliance with this permit (including but not limited to pipe length changes of 10% or greater, change in flow, pump station design capacity design change of 5% or greater, and/or change in the number/type of connections)? ❑X Yes ❑No • If yes, a permit modification request must be submitted to the appropriate Regional Office, and a modified permit with revised certification must be issued prior to certification and operation. NC DWR — Water Quality Regional Operations Section 225 Green St, Fayetteville, NC Zip 28301 Fayetteville Regional Office Phone: (910)-433-3300 FAX: (910)-486-0707 PERMITTEE: City of Laurinburg PERMIT #: WQ0041463 PROJECT: Pump Station Renovations (PS 8, 12, 13) ISSUE DATE: February 5, 2020 This project shall not be considered complete nor allowed to operate in accordance with Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation the Regional Supervisor, Water Quality Regional Operations Section at the address at the bottom. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. The Permittee is responsible for tracking all partial certifications up until a final certification is received. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection ,y tem p pi, ted herein or portions thereof. eAtilea Pik hdcl , L" • ' /`1a ' Printed Name, Title Signature ENGINEERS CERTIFICATION I, James C. Stowe, PE , as a duly registered Professional En ineer in the State of North Carolina, having been authorized to observe ( 1 periodically, weekly, ❑ full time) the construction of the project name and location as referenced above for the above Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12,1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's Seal w/signature & date: a' Final. C Partial (include description) Certification Comments/Qualifiers (attach if necessary): 30 Mar 2021 ,•c.CN `; �O oFESSIo,�.4 SEAL 32639 'FNGINE�e' •.�,: An Equal Opportunity \ Affirmative Action Employer - Made in part by recycled paper Design Notes Wastewater Facilities Contract 9.0 Pump Station Renovations (PS 8, 12, 13) AURIN9URG 30 MAR 2021 :N CAR°'',, o�oFEssio;• �,•9' SEAL 32639 ,,'S 'C. °��, Willis ENGINEERS City of Laurinburg Table of Contents Pump Station Renovations (PS 8, 12, 13) Table of Contents Project Description Section 1 Pumping Station Design Basis Section 2 System Head Calculations Section 3 System Head Curve Section 4 Force Main Velocities and Detention Times Section 5 Willis Engineers 1973.037 March 2021 City of Laurinburg Pump Station Renovations (PS 8, 12, 13) Project Description Section 1 Project Description The project consists of the complete renovation of three pumping stations, including the addition of new pumps, piping, a fiberglass wet well enclosure, electrical equipment and site improvements. One pump type having the same characteristics (impeller, horsepower, RPM, etc) will be installed at each pump station. This will allow them to be interchangeable between each of the pump stations. The selected pumps will meet or exceed the peak flow rate at each pump station, however, no additional flows are to be expected as a result of this project. Willis Engineers 1973.037 March 2021 City of Laurinburg Section 2 Pump Station Renovations (PS 8, 12, 13) Pumping Station 8 Design Basis Required Capacity Average Daily Flow Peak Factor Peak How Rate Actual Capacity Pumping Rate Excess Capacity Pump Station Diameter of Wet Well Cross Sectional Area of Wet Well Pump Start Pump Stop Pump Range Normal Volume of Wet Well Pump Performance Average Daily Flow Rate Pumping Rate Drawdown Rate Drawdown Time Fill Time Cycle Time Cycles per Hour 16,200 gpd 11 gpm 2.50 28 gpm 43 gpm 15 gpm 5 ft 19.63 sf 175.50 ft MSL 174.00 ft MSL 1.50 ft 220 gal 11 gpm 43 gpm 32 gpm 6.9 min 19.6 min 26.5 min 2.3 cy/hr Willis Engineers 1973.037 March 2021 City of Laurinburg Section 2 Pump Station Renovations (PS 8, 12, 13) Pumping Station 12 Design Basis Required Capacity Average Daily Flow Peak Factor Peak Flow Rate Actual Capacity Pumping Rate Excess Capacity Pump Station Diameter of Wet Well Cross Sectional Area of Wet Well Pump Start Pump Stop Pump Range Normal Volume of Wet Well Pump Performance Average Daily Flow Rate Pumping Rate Drawdown Rate Drawdown Time Fill Time Cycle Time Cycles per Hour 44,240 gpd 31 gpm 2.50 77 gpm 87 gpm 10 gpm 5 ft 19.63 sf 196.00 ft MSL 194.50 ft MSL 1.50 ft 220 gal 31 gpm 87 gpm 56 gpm 3.9 min 7.2 min 11.1 min 5.4 cy/hr Willis Engineers 1973.037 December 2020 City of Laurinburg Section 2 Pump Station Renovations (PS 8, 12, 13) Pumping Station 13 Design Basis Required Capacity Average Daily Flow Peak Factor Peak Flow Rate Actual Capacity Pumping Rate Excess Capacity Pump Station Diameter of Wet Well Cross Sectional Area of Wet Well Pump Start Pump Stop Pump Range Normal Volume of Wet Well Pump Performance Average Daily Flow Rate Pumping Rate Drawdown Rate Drawdown Time Fill Time Cycle Time Cycles per Hour 14,320 gpd 10 gpm 2.50 25 gpm 43 gpm 18 gpm 5 ft 19.63 sf 186.00 ft MSL 184.50 ft MSL 1.50 ft 220 gal 10 gpm 43 gpm 33 gpm 6.7 min 22.2 min 28.8 min 2.1 cy/hr Willis Engineers 1973.037 March 2021 City of Laurinburg Section 3 Pump Station Renovations (PS 8, 12, 13) PS 8 System Head Calculation System Configuration Top of Wet Well Pump Start Pumps Off Invert Wet Well Controlling Point Static Head 190.76 175.50 174.00 172.06 204.00 30.00 ft MSL ft MSL ft MSL ft MSL ft MSL ft MSL System Head Curve with Empty Wet Well Approximate System Head Curve Friction losses based on C = 110 Diameter (in) 2 Length (ft) 65 Sum K 6.2 Q (gpm) 43 2 1115 0.3 Hf 4.0 System Head Operating Points Hm Hf 1.8 68.7 System Head Hm 0.1 TDH 104.7 Q (gpm) Hf Hm Hf Hm TDH 0 0.0 0.0 0.0 0.0 30.0 5 0.1 0.0 1.3 0.0 31.4 10 0.3 0.1 4.7 0.0 35.1 15 0.6 0.2 10.0 0.0 40.8 20 1.0 0.4 17.0 0.0 48.5 25 1.5 0.6 25.8 0.0 57.9 30 2.1 0.9 36.1 0.0 69.1 35 2.8 1.2 48.0 0.1 82.1 40 3.6 1.6 61.5 0.1 96.7 45 4.5 2.0 76.4 0.1 113.0 50 5.4 2.5 92.9 0.1 130.9 55 6.5 3.0 110.8 0.1 150.4 60 7.6 3.6 130.1 0.2 171.5 Willis Engineers 1973.037 March 2021 City of Laurinburg Section 3 Pump Station Renovations (PS 8, 12, 13) PS 12 System Head Calculation System Configuration Top of Wet Well 212.38 ft MSL Pump Start 196.00 ft MSL Pumps Off 194.50 ft MSL Invert Wet Well 192.38 ft MSL Controlling Point 219.00 ft MSL Static Head 24.50 ft MSL System Head Curve with Empty Wet Well Approximate System Head Curve Friction losses based on C = 110 Diameter (in) 2 Length (ft) 63 Sum K 5.7 Q (gpm) 90 4 1876 1.4 Hf 15.6 System Head Operating Points Hm Hf 7.5 15.9 System Head Hm 0.1 TDH 63.6 Q (gpm) Hf Hm Hf Hm TDH 0 0.0 0.0 0.0 0.0 24.5 10 0.3 0.1 0.3 0.0 25.1 20 1.0 0.4 1.0 0.0 26.8 30 2.0 0.8 2.1 0.0 29.5 40 3.5 1.5 3.5 0.0 33.0 50 5.2 2.3 5.4 0.0 37.5 60 7.4 3.3 7.5 0.1 42.7 70 9.8 4.5 10.0 0.1 48.9 80 12.5 5.9 12.8 0.1 55.8 90 15.6 7.5 15.9 0.1 63.6 100 18.9 9.2 19.3 0.1 72.1 110 22.6 11.2 23.0 0.2 81.5 120 26.5 13.3 27.1 0.2 91.6 130 30.7 15.6 31.4 0.2 102.5 140 35.2 18.1 36.0 0.3 114.1 150 40.0 20.8 40.9 0.3 126.6 Willis Engineers 1973.037 March 2021 City of Laurinburg Section 3 Pump Station Renovations (PS 8, 12, 13) PS 13 System Head Calculation System Configuration Top of Wet Well Pump Start Pumps Off Invert Wet Well Controlling Point Static Head 199.58 186.00 184.50 182.45 211.00 26.50 ft MSL ft MSL ft MSL ft MSL ft MSL ft MSL System Head Curve with empty wet well and PS 6 and 16 online, adding 85 and 35 GPM of flow to the force main, respectively Approximate System Head Curve Friction losses based on C = 110 Diameter (in) 2 Length (ft) 73 Sum K 6.2 Q (gpm) 43 2 474 4 4 666 3 4 1169 3.3 Hf 4.5 System Head Operating Points Hm Hf Hm Hf Hm 1 Hf 1.8 29.2 1.2 10.8 0.5 29.6 System Head Hm 0.9 TDH 104.9 Q (gpm) Hf Hm Hf Hm Hf Hm Hf Hm TDH 0 0.0 0.0 0.0 0.0 5.1 0.2 16.9 0.5 49.1 5 0.1 0.0 0.6 0.0 5.6 0.2 18.2 0.5 51.8 10 0.3 0.1 2.0 0.1 6.2 0.3 19.6 0.6 55.6 15 0.7 0.2 4.3 0.1 6.9 0.3 21.0 0.6 60.5 20 1.1 0.4 7.2 0.3 7.5 0.3 22.4 0.7 66.5 25 1.7 0.6 11.0 0.4 8.2 0.4 23.9 0.7 73.4 30 2.4 0.9 15.3 0.6 8.9 0.4 25.5 0.8 81.2 35 3.1 1.2 20.4 0.8 9.6 0.4 27.1 0.8 90.0 40 4.0 1.6 26.1 1.0 10.4 0.5 28.7 0.9 99.7 45 5.0 2.0 32.5 1.3 11.1 0.5 30.4 0.9 110.3 50 6.1 2.5 39.5 1.6 12.0 0.6 32.1 1.0 121.8 55 7.2 3.0 47.1 2.0 12.8 0.6 33.9 1.0 134.1 60 8.5 3.6 55.3 2.3 13.6 0.6 35.7 1.1 147.3 65 9.9 4.2 64.1 2.7 14.5 0.7 37.6 1.1 161.4 70 11.3 4.9 73.6 3.2 15.4 0.7 39.5 1.2 176.3 75 12.8 5.6 83.6 3.6 16.4 0.8 41.4 1.3 192.0 Willis Engineers 1973.037 March 2021 c 0 0 N N City of Laurinburg PS System Head Curves Pump Station Renovations (PS 8, 12, 13) 0 c-I 0 N c-I O O 00 lD O}) Hal 0 O N Operating Point 0 0 0 N cI 0 0 O 00 O 0 2 a 0 Willis Engineers March 2021 r m 0 m 01 c--I City of Laurinburg PS System Head Curves Pump Station Renovations (PS 8, 12, 13) Operating Point • 0 0 0 0 0 0 0 0 N 0 00 Lc) d' N c-1 c-1 c-1 (AA Hal 0 N c-1 0 0 0 N 0 a w 0 Willis Engineers March 2021 C 0 L) a) PS System Head Curves 0 O r-1 O O 00 LO (01) Hal Operating Point O O O N 0 N r-I 0 lID 0 N 0 Flow (GPM) Willis Engineers City of Laurinburg Section 5 Pump Station Renovations (PS 8, 12, 13) Force Main Velocities and Detention Times Pump Station 8 Velocity Conditions Force Main 2 inch Flow Rate - One Pump 35 gpm Velocity 3.6 fps Detention Times Piping Volume Dia. L Vol (in) ft (gal) 2 65 11 2 1115 182 Total Volume in Piping 192 gal Average Daily Flow 16,200 gpd Detention Time 0.01 Days Pump Station 12 Velocity Conditions Force Main 4 inch Flow Rate - One Pump 87 gpm Velocity 2.2 fps Detention Times Piping Volume Dia. L Vol (in) ft (gal) 2 63 10 4 1876 1224 Total Volume in Piping 1,234 gal Average Daily Flow 44,240 gpd Detention Time 0.03 Days Pump Station 13 Velocity Conditions Force Main 4 inch Flow Rate - One Pump 33 gpm Velocity 0.8 fps Detention Times Piping Volume Dia. L Vol (in) ft (gal) 2 547 89 4 1835 1197 Total Volume in Piping 1,286 gal Average Daily Flow 14,320 gpd Detention Time 0.09 Days Willis Engineers 1973.037 March 2021