HomeMy WebLinkAboutWQ0041254_Regional Office Historical File Pre 2018' Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION PECENEDNeDE:NRIDWF: Application Nurnher: o be conipkud h DWR) All items must be completed or the application iil be returned I. APPLICANT INFORMATION: Applicant's name: Town of Hanis:burg company, municipality. HOA, utility, etc.) 2„ Applicant type: Individual E:1 Federal Corporation 0 General Partnership LI Priyately-Owned Public Utility 0 State/County Municipal 0 Other 3, Signature authority's name: Robert Donham per 15.A NC A C (12'1 ,0 1 06011 Title: Engineering & Public Works Director 4. Applicant's mailing address: 5405 Harrisburg industrial Park Drive Citv, Harrisburg State: NC Zip: 28075- 5. Applicant's contact information: Phone number: (704) 455-5614 Email Address: rdonham@harrisburvnc.org IL PROJECT INFORMATION: I, Project name: Harrisburg Park - Phase 1 2, Application/Project status: Proposed (New Perini() 0 Existing Permit/Project and issued date: _ If new construction but part of a master plan, provide the existing permit number: WQ00 3. County- where project is located: Cabarrus 4. Approximate Coordinates (Decimal Degrees): Latitude: 35,31625Longitude: -80,65981' 5, Parcel ID (if applicable): 5507-54-6216, 5507-44-3477, 5507-34-6087,5507-45-2154 (or Parcel ID to closest downstream. sewer) If a modification, provide the existing ,permit number: WQ00 III. CONSULTANT INFORMATION: I. Professional Engineer: Lester A. Barnes License Number: 040973 Firm: Alfred Renesch & Company Mailing address: 2359 Perimeter Pointe Parkway, Suite 350 City: Charlotte State: NC Zip: 28208- Phone number: (704) 521-9880 Email Address: lbamesibenesch.com I. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Rocky River Permit Number: NC0036269 ON's'ner Narne: \NSPCC V. RECEIVING DOWNSTREAM SEWER 'INFORMATION (if different than WWTF): 1. Permit Number(s): WQCS 0032 Ca Downstream (Receiving) Sewer Size:: inch System. Wide Collection •i4vstem Permit Number(salf applicable): WQCS Owner Names): IbWV1 01- ktctr1/6Wr,„fi FORM: FTA 04-16 Page 1 of 5 VI. GENERAL, REQUIREMENTS 1. If the Applicant is a Priviitely-O‘Aned Public Utility, has a Certificate of Public Convenience and Necessity been attached? Li Yes FIN() 'N/A 11 the \ppliLanl is a Developer c)f lots to be sold, has a Developer's Operational \zrtemcnt (T.ORM: DEV) been attached? ri Yes 0No 3. lithe Applicant is a Home/Propert Ovuer ssociation. has an Qarational Agreement4j OR.M. ieen attached'? 0 Yes TIN° HE" N/A 4. Origin of waste‘vater: (check all )ha) apply). 0 Residential Owned II Residential Leased Li school preschool / day care Z Food and drink facilities LI Businesses !' offices/ lactories Retail (stores.. centers, mails) Retail with food preparation/serviee Medical / dental / veterinary facilities Church Nursing, Home Car Wash 0 Hotel and/or Motels Z Swimming Pool ;(lubhouse Swimming Pool/filter liack.wash 0 Other (Explain in Attachment) 5. Nature of wastewater 100 Domestie/Commercial (voCOITIITlercial '14) Industrial (See 15A NCAC 021:0103(20 1) *Is there a Pretreatment Program in effect? Li Yes E No 6, Has a flow reduction been approved under 15A .NCAC 02T .011Ltft)? 0 Yes if ves, pro.,vide a copy of flow reduction approval letter Summariae ewater generated f), project: No Establishment Type (see 02T.0114(0) Daily Design How 1`2'11 1 Amphitheater 5 Lal/dayiseat No. of L nits 4,800 Coitcessions 250 gal/d.ay/fixture picnic Shelter 250 gai/day/fixture Restroorn Bui Id s 2.50 ual dz-ty /fixture gal/ gall Flow 24..000 CiPD .28 7,000 GPD 17 ,000 GPD 4,250 GPD GPI) GPI) Total 36,250 GPD See 1.5A NCAC 021/ „0 1410.1. Id 1. tel(1.) and (e)(2) (by caveats to wastewater design flow rates (i,e., minim inn flow per dwelling: proposed unknown non-residential development uses; public access facilities IOCated near hick public use areas: and residential property located south or east or the Atlantic Intracoastal Waterway to be u.sed as vieation rentals as defined O.S. 42.A.-4). Per 1,5A N.(111/\C 02111,01E4(4 design .11.ow rates for establishments not identified [in table 15,A C 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other IlleatiUred data. 8. Wastewfiter generated by project: 36.250 GPD ( per 15A NcAC 021.011.41i Do not include future flows or previously permitted allocations if permitted t1os is zero, indicate why: Li Pump Station or Gravity Sewer where flow will he permitted in subsequent permits that connect to this line n Flow ha.s already been allocated in Permit Number Li Rehabilitatnin or replace t of existing sewer with no new flow expected ri ()titer (1,xplairf1. FOR .N1 1T, Page 705 VII. GRAVITY SEWER DESIGN CRITERIA vlieable) - .0305 & DC (Gravity Sewers): 6 1, Summarize t",,,,raVit) sewer to be permitted; Size Length (feet) Material 8 1.20 DIP 8 1,208 PVC Section of the MI)C for Permitting of Gravity Sewers contains information related to design criteria Section III contains information„related to minimum slopes for gravity sewer(s) • Oversizing lines to meet minimum .slope requirement is not allowed and a violation of the MDC VTII, PUMP STATION DESIGN CRITERIA (If Applicable) 02T .0305 & M DC trump Stations/Force Maims): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1, Pump station number or name: 2, Approximate Coordinates (Decimal Degrees): Latitude: 'Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4, Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TD(-1) 5, Simunarize the force main to he permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with. 1.5A NCAC 02T .030.500(1): L.] Standby power source or pump with automatic activation and telemetry 15A NCAC 02T ,0305(h)(1)(1 • Required for all pump stations with an average daily flow greater than or equal to 15„000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: P• ortable power source with manual activation, quick -connection receptacle, and telemetry - 15A NCAC 02'E (1305(h(1)( 1.)(C) or LI P• ortable pumping, unit with plugged emergency pump connection and .telemetry - 15A NCA( 02'1 .0305(h)(1)(C): .`i-• It shall he demonstrmed to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. If the portable, power source or pump is dedicated to multiple pump stations, an evaluation of all the pomp stations' storage capacities ind he rotation schedule of the portable power source or pump, including travel timcfranics, s'hall be provided in the case of a inultiple station power outau,,e, f ORM: 1 1 A 1)41, Page 3 of IX. SETBACKS & SEPARATIONS — (028 .0200 & I5A, NCAC 02T .0305(0)i 1. Does the project comply with all separations 'found in I5A NCAC 02T .0305( & El Yes 5A NCAC 02T„0305(f) contains minimum senarati its that shall be provided for sewer systems: Setback Parameter* Rciquired___„ v-rs and other 'utilities not listed below (vertical) 24 inches Water mains vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) Reclaimed water lincsAyertical - reclaimed over sewer) Reclaimed water lines (horizontal - reclaimed ver SOLT]) 'Any private or public water supply source, including any wells. WS-1 waters of Class 1 or Class II impounded reservoirs used as a source of drinking water **Waters classified WS (except WS-I or WS-V), B, SA, ORW, IIQW, ur SF3 from normal water (or tide etevati and wetlands :(see item .1X,2) Any other stream, lake, impoundment, or ground water lowering and surface drainage. 1 ditches 10 feet [Any building foundation 5 feet Any basement 10 feet 'Top slope of embankment or cuts of 2 feet or more vertical height. 10 feet Drainage sLstems and interceptor drains 5 feet Any swimmingToois 10 feet earthsradc (vertical) „ inelies 10 feet 18 inches 2 feet l 00 feet 50 feet I 5A N. ted.0 4)5(,) contains alternatives where separations in r)2:1Q.305( I) cannot be achieved, ;-'• **Stream classifications can be identified using the Division's NC Stu face WatL'1 Classilicai ions, welTage r' If noncompliance with t)„,,?, f0t,i'41)1TGosee Section X of this application 2. Does the project comply with separation requirements fur wetland,s? (50 feet of separation) Z Yes See the Division's draft separation requirements for situations where separation cannot be meet No variance is required if the alternative design criteria specified is utilized in design and construction As built documents should reference the location of Etc eas effected 3, Does the project comply with setbacks found in the river basin rules per I 5A NCAC 0213 .0200? • This would include Trout Buffered Streams per ]„5„A NC.A(.2, 213.0202 4, Does the project require coveragelauthorization under a 404 'Nationwide or individual permits or 401 Water Quality Certifications? • information can he obtained from the &, Buffer Permitting Branch No No El NIA E.] Yes Z No 5, Due S project comply with I 5A N(.,7AC 0240 0510E0 (additional permits/certifications)? Y e Per 15,A. NCAC ) 0 05(e)L0 , directly related environmental pet -nuts or certification applications are being p1 epared,. have been applied for, or have been obtained, Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, storinwater management plans, etc.). 6, Does this project include any sewer collection lines that are deemed "high -priority?" Per I 5A NCAC 0 1 .0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks, that is subject to erosion that undermines or deter ionites the sewer, Li Yes LJ No Z N/A • lf yes, include an attachment with details for each line, including type (aeriul hilL. size, material, and location). High priority lines shall Ire inspected by the perm it tee or its representative at least once every six -months and inspections documented per 15.A NCAC 02T.04103(a)(5) or the perm itee"s individual System -Wide Collection permit, Form FrA 0,4- 16 Page 4 of .5 CERTIFICATIONS: Does the submitted system comply with I.5A NCAC 021, the Minimum Desian Criteria for the Permitting of Pump Stations zind Force Mains tlatestversion)., and the Gravity Sewer Minimum Design Criteria (latest versioni as applicable? Yes El No If No, complete and submit the Variance/Alternative Desien Request application (V ADC 10-14) and supporting documents for review. Approval of thereouest is required prior to submittal of the Fast Track Application and supporting documents,. 2. Professional Engineer's Certification: LA.A4E (Professional Engineer's name from Application Item 1111) attest that this application for has been reviewed by me and is accurate, complete arid consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version)„Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design, NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed 510,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3, Applicant's Certification per 15A NCAC 021 .0 I06(b): 1, .. 4:'be' 03 (Signature Authorit)'s name & title from Application Item 1.3.) st that this applicat for has been reviet,ved by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete, I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, andior criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-21.5.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilt) of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Date: \\ / FORM: FTA 04-16 Page 5 of 5 WSACC November 2 , 2019 Mr, Haynes Brigman Town Manager Town of Harrisburg P.O. Box 100 Harrisburg, NC 28075 Subject: Flow Acceptance Request - Town of Harrisburg Harrisburg Park — Additional Flow Dear Mr. Brigrnan: WATER & SEWER AUTHORITY OF C.ABARRUS COUNTY 232 Davidson Hwy. Concord, NC 28027 704.786.1783 • 704.795.1564 Fax w.vw.wsacc.onj This is a notice of capacity for the flow acceptance request received by the Water and Sewer Authority of Cabarrus County (WSACC) from the Town of Harrisburg on November 22, 2019. WSACC has or will have capacity at the Rocky River Regional Wastewater Treatment Plant and appropriate sewer interceptors to transport and treat the domestic wastewater from the proposed park expansion and improvements. WSACC previously accepted 13,000 gallons per day (gpd) associated with the referenced park expansion. WSACC accepts an additional 23,250 gpd with the current request, for a total of 36,250 gpd accepted for the park expansion overall. The wastewater generated by this project will be conveyed through a proposed gravity system and then enter WSACC's system at the existing 12-inch Back Creek Interceptor. WSACC acknowledges it has or will have capacity for wastewater from the proposed development based on information provided by Alfred Benesch & Company and Town of Harrisburg using North Carolina Department of Environmental Quality (NCDEQ) wastewater flow guidelines. The WSACC Capital Improvement Program (CIP) has been on pay as you go since Fiscal Year 2005 — 2006, funding Capital Projects entirely from Capital Reserves, and WSACC expects to continue this policy into the future. Projects on the CIP are subject to approval by WSACC's Board of Directors, support from local governing bodies, regulatory approval, and funding availability. The list and schedule of CIP projects are tentative and are revised periodically to reflect changing conditions and needs. If construction of this project does not commence within two (2) years of the date of this notice, the notice is rescinded and a second request and notice will be required before flow capacity is accepted. Please notify WSACC, in writing, when construction of this project is initiated, This sewer capacity allocation may also be cancelled pursuant to the conditions set forth in the WSACC Sewer Allocation and Commitment Policy. Please note that the final commitment to service to provide wastewater treatment services shall occur upon application for a building permit for the project and when system development fees are paid pursuant to N.CG.S. §162A, Article 8. If you have any questions, please call me at (704) 788-4164, extension 104. Sincerely, J. Thomas Hahn, PE Utility Systems Engineer cc: Rob Donhain, PE/Harrisburg Lester A. Barnes, PE/Alfred Benesch & Company Michael Wilson/WSACC Chad VonCannon, PE/WSACC Mark Lomax/WSACC Trent Gobble/WSACC WASTEWATER FLOW ACCEPTANCE FORM FOR THE WATER AND SEWER AUTHORITY OF CABARRUS COUNTY Jurisdiction Requesting Flow Acceptance: ©City of Concord E1Ciity of Kannapo,lis WiTown of Harrisburg []Town of Mt. Pleasant (_]Charlotte Mecklenburg Utilities. Project Title, Description, and Number of Lots/Unit: Project Title: Harrisburg Park Phase 1 Description Park expansion and hnpr©vemeuta Including new amplrltheaterp sttlttstt Pad. Plavt'rttattd, restrooms, concession budding, si eccr fields, driveway extensions, and new parking lots with underground utilities and stormwater wet pond, Date: *Number of Lots: OR *Number of Units: *i'yl st be in hided in request. Where will the new line be connected: © Directly into a WSACC Interceptor Into the Jurisdiction's existing collection system Into a private line Describe the location of the tie -ha line to which the new sewer line wilt connect: Tie in loco i,on, will be rdt the sootlrslde of the protect site and utilize an inside drop doghouse umbel e t© Ile Into the existing sewer line, Which. WSACC Interceptor will the flow ultimately be discharged into: Back Creek. What is the WSACC manhole number that the flow will be discharged in tn'I 010171 What is the quantity of flow that will be discharged? '3fr,45f3GPD Flaw type: (CZ__ `1 i 1st) c..0 AQ {1 0u N A i. 1 Domestic 100 % 0 Commercial %4 © industrial %a Name of wastewater treatment facility (WWTF) receiving wastewater: Rocky River Wastewater Treatment Facility — Permit #NC0036269 Muddy Creek Wastewater Treatment Facility— Permit #NC008l62I Design drawings of new lines will be submitted to WSACC with the request for nccepttxnce, Drawings can be submitted as a digital file (DWG) or distance and bearing starting with the tap on existing infresirtrctu If the new line is to connect directly into a WSACC interceptor, detailed drawings including specification of the tap, will be required before flow acceptance will be provided. Mark Lomax at 704-786-1783, ext, 23 9 , oarst be notified 48 hours in advance of a connection into a WSACC interceptor. WSACC will .inspect connection before, during, and after completion. If construction is not started within two (2) year fi ortr the date of approval of Mellow acceptance for this project, The approval is rescinder/ and a second request and approval will be required for the project, WSACC 'USE i3NLY: Current sew Model shows Approved ttjtifrrq= Current Sewer Model shows: (. A LL .O er S P ri- DATE: being surcharged south of the manhole in question, Not Approved. (M:.&I ITY F'n. (Vdo IT) Ot4A (_vNO1Tttr'r^'i Division of Water Resourtes Flow Tracking/.Aceet (JURISDICTION USE ONLY) State of North Carolina Department of Environmental Quality Division of 'Water Resources aitce ft. • Sewer Extension Permit Applications (FTSE —01 /14) Jurisdiction Requesting Flow Acceptance for Collection System: EiCity ()I'Concord Eleity or .K.annapolis 'flown of Harrisburg riTokvn of NIL Pleasant jlharlotte Mecklenburg Utilities Project 'Fide, Description, and Number of Lotsitri it Project Title: Ha rristuarg Park Phase Description: Park expansion and improvements including new amphitheater, splash pad. n indrestrooniconeessiian building, soccer fields, driveway eqtansion and new parking lois, What is the quantity of flow that will be discharged? 36,250 How type: Domestic 100 o Li Com fll e a GPD 111 Industrial Section 1 - List the Jurisdiction's pump stations located betio.een the project connection point and Interceptor connection point: Pomp Si1ir Name Firm 1 d1i5I 15 13.est.n., Average Daiiy Flow (Tit -mirk) [3`) Applox, Currera Avmtge0 Is!low MG!) he WSACC T , .it.)") - ai",Ci.' ' (F)=0-1)9 Oblikotical, ..`,;,,m: Yes 1 Total CLarrent Pow ',„iikiblt, Tributar) Dafly How , Pitt,,,. Obli8i,A,,,k1 Flo, Capacity.,,,, 51(,,;11 51G1) Nita) ' The. Firm Capacity of any titurrip station is defined a!: the maximum pumped flaw that can 17* achieved Nrith the tare-t pmni, taken tnnot set', ice, **Design .Averagia Doily Fitns is the firm capacity or the pump station divided i i peaking Factor not its than 2.5, Planning Assossmeot „ii.dtlepaltitat shall he ,Iftincherl for 00.6 pomp station located between the project connection. point and the VI N'Y'rP where 5utiui 3 Section. 11—lurisiliction's Certification Statement: 1. certify that, to the best of my knowledge, the 'addition or the volume of wastewi-iter to be permitted in this project has been evaluated along the route to the receiving WSACC interceptor; and the flow from this. project is not anticipated to cause i-iny capacity related sanitary sewer overflows or overburden on any downstream pump station in route to the receiving, 'WSACC interceptor normal circumstances, (.1i5 en the implementation of the planned improvements identified in the planning .assessment where applicableThis zmalysis has been performed in totoordance with local established policies and procedures using the best ivitilable data,. Ibis certification applies to those items listed above in Section 1 plus all attached planning assessment addendums for \vhich„ to the best otmy knowlecige, will not :Idversely affect the downstream sewer ctipacity. Signature of this form indicates acceptance. of this wfistewatcr flow. cial Signotiire RL'Vr,1011 DaTe DI*'sloe of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE —10/18) (WSACC USE ONLY) Harrisburg Park — Additional Flow Section I. Narne of wastewater treatment facility (WWTF) receiving wastewater: Rocky River Wastewater Treatment Facility -- Permit #NC0036269 Muddy Creek Wastewater Treatment Facility — Permit #NC0081621 WWTP facility's permitted flow, MGD Estimated obligated flow not yet tributary o the WWTP, MGD WWTP facility's actual avg. daily flow, MGD 20.07 Total flow for this ific reuest,MGD Total actual and obligated flows to the facility, MGD Percent of permitted flow used 26.500 3,024 . 4% o 0. 23.117 87.23% Section II. Pump stations along the route from the Jurisdiction's connection point to the WWTP. Pump Station (Name or Number) (imp Station Permit No. Firm Capacity * MGD (A) Design Average Daily Flow "* (Fmnipi) MCI-) E11 Approx. Curfew Average Daily Flois MGD veer Rocky River PS 3 '269 37.000 14.800 10.541 (C) Obligated, Nat Yet Tributary Daily Flow MGD 2,423 (13)*, (13+C) (E)—(A-D) Total Current MOW Available Plus Obligated Flow MGD MGD 12,964 1 836 " The Firm Capacity {design flow) of any pump station is defined as the maximum pumped flow that can he achieved with the largest pump taken out of service. **Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (p0 not less than 2,5, per Section 2,02(A){4}(c) of the Minimum Design Criteria, Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where Available Capacity is < O. Section III, WSACC Certification Statement: I, J. Thomas Hahn, PE, certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route from the connection to the WSACC interceptor to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Section I and Section II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates WSACC's guarantee of capacity for this wastewater flow. Notwithstanding the guarantee of capacity, WSACC does not make a commitment to service this wastewater flow until a building permit is requested through the Cabarrus County Building Inspections Department and WSACC receives payment of the System Development Fee. 's Signing Official Signature q.`.1 kkkk ',447 AUTUMN WOODS, DE k tz) PARALLEL DR 34,4, 13 k.3(.35 DR I rc, 12 HUDSON DR • 3333 4,o OLEN DR; BERRY RIDGE DR r TOM QUERY RD .01 : \ Z BEDFORDSHIRE AVE HUDDERSFIELD OR r— •Xkk, „ „ —XXX SITE k, 1, St 0 . i k sBURG, , . 1 • " .4,U. ' , .4X k ''s • - " "! .4' 6 , +.4* ki Mc Cachrent., ""4"-6'', . ... „ x kr„44•"‘" , ' • - , „,kia6P:Xx.,••• • . • XI k \ 4' ' ' \'' • x t ' 600 sHAMROMRD, 041 \a, ,a41, 44,44 444, AM Hlarrisl~ urg Park — Phase 1. 13enesch Pro`ect# 17000255 August 28, 2019 Sanitary Sewer Extension Application Cover Letter project involves the expansion and redevelopment of the existing l{arrishurg Park. Amenity improvements for the park will consist of new competition soccer fields, practice fields, an amphitheater, a concessions' building, restroom buildings, shelters, a splash pad, sidewalks / walking trails, and a playground. Infrastructure improvements for the park will consist of an extension of roadway and driveway extensions, new parking lots, new/relocated water and sewer services, underground storm drainage, and a dual-purpose wet pond for irrigation and post - construction stormwater management (detention / water quality). Approximately 1,328 of new and relocated 8-inch gravity sanitary sewer mains as part of th project are being permitted with NC17EQ through the Town of Harrisburg, who also operate maintains the system. Sections of the sanitary sewer main that cannot meet minimum separation requirements of 15A NCAC 2T .0305 will he ductile iron pipe. The follow included in this sewer extension application package., The following refer to the checklist on Page 1 of the Fast. Track Application. • Fast Track Appl.icatican (FTA 04-16) ▪ Cover le • Application. Fee: $480.()0 .m ,\/\, • Wastewater Flow Acceptance Form for the W arcs' and Sewer Authority of Cabarrus County (WSACC) (F I SE) • USOS Topo Map Street View Map (Aerial) CE4TIFICATION,CHECKLIST To be completed by the certifying engineer prior to operation of the permitted sewers, per 15A NCAC 02T.0116. (rvEDIN NRONi":: Certifying Engineer: LE,STER A. Certification Review Date: 74 12,42.02.0 Project Name: IS WQOO Litzsq Project County: Wel 1) Has permittee information changed since the permit was issued (or last modified): change of mailing address, change of ownership, transfer from developer to HOA/POA, etc, E Yes • If yes, please provide either a change of ownership form or new contact information. Note that transfer of permits from the developer to the FIOA/POA must occur with the first certification. 2) Have the as -built drawings have been signed, sealed, and dated by an N.C. PE? es E No 3) Final Engineering certification? Yes • If Partial Engineering certification, provide detailed narrative including what is being certified in the current phase, what was previously certified (if applicable), and what is left to be certified. 4) Adequate information related to sewer lines: Yes fl No N/A • Three feet minimum cover has been provided for all sewers unless ferrous pipe was installed. • Minimum diameters for gravity sewers are 8-inches for public lines and 6-inches for private lines. • Manholes have been installed: At the end of each line, at all changes in grade, size, or alignment, at all intersections, and at distances not greater than 425 feet; minimum diameter shall be 4 feet (48-inches). 5) Adequate information related to pump stations: L Yes No /A • Ensure power reliability option was selected per 15A NA(j2T,V305(hi 6) Was project construction completed in accordance with all of the following: Yes No E N/A • _15A NCAC 02T, Minimum Design. Criteria (MDC) for the nertnitting of Gravity Sewers (latest version), and .MDC for the le of Punt) Stztions and Force Mains (latest version)? If not, a variance approval is required in accordance with 15A NCAC 02TA 05(h), prior to certification and operation. • Contact the Central Office to discuss the variance to determine a course of action. • Applicant must submit two copies of the variance request form, plans, specifications, calculations, and any other pertinent information. to the Central Office (one hard copy, one digital copy). • The central office will review the variance request, and if approvable, specific language regarding the variance will be incorporated into the permit, either via a special condition or a supplementary letter.. A copy of the reissued permit with variance language or the variance letter must be maintained with the original documents. 7) Does. the project contains high priority lines (15A NCAC 02T .0402(2))? Yes PrT\T • If yes, ensure that the permit already contains the necessary condition related to high priority lines 15A NCAC 02T.0403 (a)(5). If the permit does not include this language, the Fast Track reviewer will reissue the permit with the appropriate language. 8) Are Permit modifications are required for any changes resulting in non-compliance with this permit (including but not limited to pipe length changes of 10% or greater, change in flow, purnptaiiion design capacity design change of 5% or greater, andlor change in the number/type of connections)? Yes No • If yes, a permit modification request must be submitted to the appropriate Regional Office, and a modified permit with revised certification must be issued prior to certification and operation, NC DWR — Water Quality Regional Operations Section 610 East Center Avenue, Suite 301, Mooresville, NC 28115 Mooresville Regional Office Phone: (704) 663-1699 FAX: (704)-633-6040 FAST TRACK SEWER ENGINEERING CERTIFICATION PERMITTEE: TOWN OF HARRISBURG PERMIT #: WQ0041254 PROJECT: HARRISBURG PARK - PHASE 1 ISSUE DATE: DECEMBER 6, 2019 REceivEawco.ENniowR FED fi This project shall not be considered complete nor allowed to operate in accordance with standard Condition 7 of this permit until the Division has received this Certification and all required supporting documentation. It should be submitted in a manner that documents the Division's receipt. Send the required documentation to the Regional Supervisor, Water Quality Regional Operations Section at the address noted in the page footer. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, The Permittee is responsible for tracking all partial certifications up until a final certification is received by the Division. A Final Certification shall be a complete set of record drawings and design calculations regardless of whether partials have been submitted. PERMITTEE'S CERTIFICATION I, the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof, \r‘ cg0 91o30( Printed Name, Ti .=.24_21z_) ENGINEER'S CERTIFICATION I, (arm A, SMIJES , as a du gistered Professional Engineer in the State of North Carolina, having been authorized to observe ( periodically, 11 weekly, n full time) the construction of the project name and location as referenced above for the above Pemiittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction of 1,328 linear feet of 8-inch gravity sewer was observed to be built within substantial compliance of this permit; 15A NCAC 02T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials. North Carolina :Professional Engineer's Seal ix/signature & date: Final "al include description) Certification Com n /Qualifiers (attach if necessary): OP gatikwrie S ‘xpEO loSPECI160 LEITM., FAIL °DES 6 110E degriF4Ex>. C14,5) NC DWR — Water Quality Regional Operations Section 610 East Center Avenue, Suite 301, Mooresville, NC 28115 Mooresville Regional Office Phone: (704) 663-1699 FAX: (704)-633-6040 benesch Harrisburg Park — Phase 1 Benesch Project# 17000255 February 19, 2020 Sanitary Sewer Extension As -Built. Cover Letter Alfred Benesch & Company 2359 Perimeter Pointe Parkway, Suite 350 Charlotte, NC 28208 www.heneschcom P 704-52.1-9880 F 704-521-8955 This partial as -built certification is for approximately 1,326-LF of sanitary sewer lines and (5) manholes currently installed at Harrisburg Park. Acceptance of the system is based on construction observation, witness of testing, as -built drawing review, and video investigation. Manholes 1 through 4 have been vacuumed tested and passed. The installed sewer lines have been clearance (mandrel pulling) and pressure tested, Manholes 5 (not installed) and 6 (installed) will be tested prior to final certification. See the attached field report for detailed information about testing results, The following items are included in this partial as -built package. NC PE sealed As -Built Plans (Record Drawings) NC Survey sealed As -Built Drawing Sanitary Testing Field Report with results NCDEQ Certification Checklist Fast Track Sewer Engineering Certification Sanitary Sewer Video Inspection electronic files