Loading...
HomeMy WebLinkAboutWQ0040719_Regional Office Historical File Pre 201815A NCA 02f.O,' Division of Water Resourc 0 State of North Carolina Department of Environmental Quality Division of Water Resources :RACK SEWER SYSTEM EXTENSION APPLICATION ETA 04-16 & SUPPORTING DOCUMENTATION Application Number: Ito be completed by DWF2.) All items must be completed or the applkatmnwill be returned 1.APPLICAN-F INFORNIATMN: 1, Applicant's name: City of Kanna.polis -impany, municipality, 110A. utility, etc.) 2. Applicant type: LI Individual El Corporation El General Partnership El Privately -Owned Public Utility LI Federal Ei State:County .1, Signature authority's name: \i1rner kltori. 111 per 15A NCAC 02T ,0106(b) Title: Director of Public Works 4. Applicant's mailing :address: 401 I...aureate Wav City: Kannapolis State:NC Zip: 28081-0005 Applicant's contact intbrmation: Phone uumber 17, 04) 920-4200 Email Address: v me1ronhannapolisnclov IL PROJECT INFORALSTION: 1. Project name: Crescent Stree • Wa c d Sewer Improvement Application Project status: ' Proposed (New Permit) El Other LI Existing Permit/Project If a modification, provide the existing permit number: WOOD and issued date: if new construction but part of a master plan, provide the existing permit number: 'WOO° 3: County where project is located: Cabarrus 4, Approximate Coordinates (Decimal Degrees): Latitude: .35,465660 Longitude; -80,621452' .5. Parcel ID (if applicable): within road RAN' between parcels 5612-69-8136 and 56 2-79-1079 (or Parcel ID to closest downstream sewer) In. CONSULTANT INFORMATION: 1. Professional Engineer: Elizabeth .Firin: City of Kannapolis Mailing address: 401 .Eaureate 'Way City: Kannapolis State: NC Zip: 28081-000.5 Phone number (704i 920-4200 E•mail Acklress: ehassentritzf'rRkantrapolisnc,gov IV.. WASTEWATER TREA-FMENT .EACILEFY (WW-IT) INFORMATION: 1, Facility Name: Rocky River Regional Wastewater Treatment Plant Pernnt N Owner Name: Water & Sewer .Authoritv of Caburrus County License Number NC 030941 NC0036269 V. RECEIVING DO.\ NSTREAM SEWER INFORMATION (if different than WWTE): 1, Permit Number(s): System Wide Collection System Permit Number( -) it'applicable): WOCS_, Owner Nameis): FORM: 1TA Page 1 of 5 VI GENERAL REQUIREMENTS 1 lfthe is a Privately -Owned Public Utility, has a Certificate of Public ( onentence and Necessity been attached? El Yes EjNo EN/A 2, If the ,Npplicant is a Developer of lots to be sold, has a Developer's Operational Agreement iFORM: DEV) been attached? Ej Yes EINo ZN/A I If the Applicant is, a Horne 'P p,ern0wner5,,.\ssociation, has an Operational Agreement.(FORM: 1,10A) been a ached? El Yes No NA 4. Origin of wastewater: (check .a El Residential Owned Residential Leased El School. 1 preschool day care Ej Food and diink. facilities El Businesses / offices/ factories apply): LJ Retail (stores, centers, malls) El Retail W ith food preparationiservice LI N4edical dental veterinary facilities D Church El 'Nursing Horne 5., Nature of wastewater 100 Domestic ( ommercial 00o Commercial % Industrial tSee 1.5A, NCAC 0.21 .0103(20)) Is there a Pretreatment Program in effect.? LJ Car IN'ash [1 Hotel and or Iklotels Swi„mining Pool /Clubhouse Swimmin.L2: Pool filter Back ash El Other (Explain in Atta.chment) N es 6.Has a flow reduction been approved under 15A NCAC 02T ,0114(f)? E] Yes No If ves, provide a copy of flow reduction approval letter 7, Summarize wastewater generated by project: Establishment Type (see 02T.0114(0) Daily Design Flow a'b 3 bedroom dwellin,-2; units 360. gal dagaP No,, of Un't, Flow 2,520 GPD GPI) GPD GPD GPD foto/ 2,520 opt-) a See 15A. NCA.0 02T .0114 d" 'e 'or caveats to ‘vastetvater des'gn flow rates (i.e., minimum 'flow per dwelling: proposed unknown non-residential development uses; public access facilities located near high public use. areas: and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G,S..42A-4). Per 1.5.A NCAC 02'r .0114(c), design flow rates for establishments not identified tin table I5A NCAC 0211.0114j shall he determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. Y. Wastewater generated by project: 2,520 GPD (per 15A NCAC 02T .0114) 1Do not ;include future .flows or previously permitted allocations If permitted flow is zero. indicate why: Lil Pump Station or Gravity Se‘ver where flow will be permitted in subsequent permits that connect to this line [i] How has already been allocated in Permit Number: ['Rehabilitation or replacement of existing sewer with no new flow expected 1:11 Other (Explain): FORA': 11A )4- Noe 2 of 5 . GR,AV1TY SEWER DESIGN CRITERIA (If Applicable) - 02f .0305 & MDC (Gt. Summarize gravity sewer to be permitted: Size (inches) Length (feet) .Material 246 PVC Section II & 111 of the MDC for Permitting of -Gravity Sewers contains information related to design criteria Section Ell contains information related to minimum slopes for gravity sewerfs Oversizing lines to meet minimum slope .requirement is not allowed and a violation of the NID( VIII. PUMP STATION DESIGN CRITERIA Of Applicable).— 02T .0305 &MDC (Pump Stations/Force Mai COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT Pump st.tion numher or name: NIA. 2. Approximate Coordinates (Decimal Degrees): Latitude: longitude: - 1, Design flow of the pump station: millions gallons per day (firm capacity) 4, Operational point( of the piimp(s): gallons per minute at feet total dynamic head ('TDIT) 5, Summarize the 'force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance ‘Vith. 15A NCAC 02-1 .0305(h)(1.): [1] Standby power source or pump with automatic activation and telemetry - I.5A NCAC 02T ,14305(h)(1 )(Bt: Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facilit,,- Oi lithe pump station has an average daily flow less than 15,000 gallons per day: E Portable power source \vith manual activation, quick -connection receptacle and telemetry - 15A NC.,'AC: 02T 0305di0 )(C) or E Portable pumping unit \vith plagued emergency pump connection and telemetry - 15A -NCAC 021- :0305(h)(I)(C): It shall be demonstrated to the Division that the portable source is owned. or contracted hy the applicant (draft. itureement1 and is compatible vvith the station, 1.1 the portable power source or pump is dedicated to multiple pump stations, an evaluation of 'all the pump stations' storage capacities and the rotation schedule of th.e portable power source or pump, includinu travel timell-ames, shall be provided in the CaSC o F a multiple station power outage, FORM: ETA 04-16 Page .1 of 5 SETBACKS & SEPARATIONS -(02B .0200 & I 5A NCAC 02T ..0305(f)): 1 Does the project comply with all separations found in 15A NCAC 02T 05: & • 15A NCAC 021,0305(0 contains minimum separations that shalt be prov' Setback Parameter* Yes No Separation Required Storm s wersand other utilities not listed below (vertical) 24 niche: Vater mains (vertical -water OVer sewer including in benched trenches)18 inches Tater rnais (horizontal) Reclaime Nvater lines vertical - reclaimed over sewer) ed water line izontal - reclaimed over sewer) 10 feet 18 inches 2 feet **A.ny private or publicwater supply source, including any welk, WS-1 waters of Class 1 or lass11 impounded reservoirs used as a source of drinking water **Waters classified WS (except WS-I or WS-V), B, S. ORW, HOW, or SB from normal high water (or tide elevation) and wetlands (see item 1X.2.) *Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches Anv buildine ndation v basement slo e o Drainage s stems and interceptor drains v swimming pools al earth grade (vertical) 'embankment or cuts of 2 feet or more vertical heiuht 100 feet 50 le 10 .leet 5 feet 10 feet 10 feet 5 feet 10 feet 36 inches 15A. NCAC 02T.0305(gi contains alternatives where separations in 021,030515) cannot be achieved. • **Stream classifications can he identified using the Division's NC Surface WaterVatr Classitications ve; • linoricom.pliance with 02T.0305(0 or (g), see Section X of this application 2. Does the project comply .with separation requirements for wetlands? (50 feet of separation) • See the Division's draft separation requirements for situations where separation cannot be meet ▪ No variance is required if the alternative design criteriaspecified is utilized in design and construction • As built documents should reference the location of areas effected aLTe Y S El No .3, Does the project comply' with all setbacks found in the river basin rules per 4.5A NCAC 02.B .0200? El Yes El No -> This would include Trout Buffered Streams per 15,A NCAC 213.0202 4. Does the project comply with au individual 40,4 Permit or au ±„' ,401 Certifications? El Yes No • Wetland -related permits shall be requested, obtained, and adhered to frit projects that impact wetlands or surface waters Information can be obtained from the 4,01 & Buffer Permitting Branch 5. Does projectcomply with 15A NCAC 02T.0 105[01_6) (additional permits/certifications)? Yes El No Per 15A NCAC 02'[.0105(c)(6). directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permit's (erosion and sedimentation control plans, stormwater management plans, etc.). 6, Does this project include any sewer ,collection lines that are deemed "high -priority?" Per I 5A NCAC 011.0402, "high -priority sewer" means -any aerial sewer, sewer contacting surface 'waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer, 11 Yes E. No • yes, include an attachment with detailsfor each line, including type (aerial line, size, material, and locatiui 1 High priority lines shall he inspected by the permittee or its representative at least once every six -months arid inspections documented per 15A NCAC 021'.0403(a)(5) or the permitee's individual System -Wide Collection permit. .1 0 R.M: FT.A. 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with I5A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and .Force Mains (latest version). and the Gravity,Sewer MinimumDesign Criteria (latest version) as applicable? Yes LINo If No, complete and submit the Varia.nce/Alternative Design Request application (VADC 10-14) and. supporting documents for review, Approval of the request required prior to submittal of the Fast Track Application and supporting documents% 2. Professional Engineer's Certification: O" AZ (Profess anal Engineer's 'name from Applicati IMF) attest that this application for has been reviewed by: me and is accurate„ complete and .consistent with the information supplied in the plans, specifications, engineering calculations„ and all other supporting documentation to the best of my knowledge. 1 further attest that to the hest of my knowled.ge: the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design. Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast-lfrack Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed cettain pi:micas of this submittal package, inclusion of :these materials under my signature and seal signifies that I. have reviewed this materialand have judged it to be consistent ‘vith the proposed design, NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall he ,guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000. as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: • 4 • 4#04. • 1-* - SE AL 3.. Applicant's Certification per 115A„NCAC 02T .0106(b); (Signature Authority's name & title from Applica attest that this application for has been reviewed by OW and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and ,attachments are not included, this application package is subject to being returned as incomplete, I understand that any discharge of wastewater tlicim this non - discharge system to surface waters or the land Will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution, I willmake no claim .against the Division. of Water Resources should a condition. of this permit he violated., I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included., this application package will he [-chimed to me as incomplete, NOIE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any :false statement, representation, or certifieation in any application package shall be guilty of a Class 2 misdemeanor:, which may include a fine not to exceed S.I 0,000 as well as civil penalties up to $25„000 per:violation_ Signature: Date: FORM: FT'. 0k16 Page 5 ©f 5 Proposed 8 inch Sewer Extension Crescent Street Sewer Extension Kannapolis, NC 0 1,000 2,000 Feet 1 inch = 1,000 feet Crescent Street Sewer Extension Kannapolis, NC WSACC March 6, 2019 Mr. Michael Legg. City Manager City of Kannapolis 401 Laureate Way Kannapolis, NC 28081 Subject: Flow Acceptance Request — City of Kannapolis Crescent Street Water and Sewer Improvement Dear Mr. WATER & SEWER AUTt-IURITI' OF CABARRUS COUNTY 232 Davidson Hwy. Concord, NC 28027 704.786.1783 • 704.795.1564 Fax www.wsacc.org 1 2O This is a notice of capacity for the flow acceptance request received. by the Water and Sewer Authority of Cabarrus County (WSACC) from the City of Kannapolis on March 5, 2019. WSACC has or will have capacity at the Rocky River Regional Wastewater Treatment Plant and appropriate sewer interceptors to transport and treat the domestic wastewater from the proposed project entitled Crescent Street Water and Sewer Improvement, located along Crescent Street. The referenced project will serve seven homes,. with a projected wastewater flow of 2,520 gallons per day (gpd). The wastewater generated by this project will be conveyed through a proposed gravity system, through the existing gravity system, and then enter WSACC's system at the existing 48-inch Irish Buffalo Creek Interceptor. WSACC acknowledges it has or will have capacity for wastewater from the proposed development based on information provided by City of Kannapolis (Civil Engineer for the project) using North Carolina Department of Environmental Quality (NCDEQ) wastewater flow guidelines, The WSACC Capital Improvement Program (CIP) has been on pay as you go since Fiscal Year 2005 -- 2006, funding Capital Projects entirely from Capital Reserves, and WSACC expects to continue this policy into the future. Projects on the CIP are subject to approval by WSACC's Board of Directors, support from local governing bodies, regulatory approval, and funding availability. The .list and schedule of CIP projects are tentative and are revised periodically to reflect changing conditions and needs, If construction of this project does not corrnnence within two (2) years of the date of this notice, the notice is rescinded and a second request and notice will be required before flow capacity is accepted. Please notify WSACC, Itt writing, when construction of this project is initiated. This sewer capacity allocation may also be cancelled pursuant to the conditions set forth in the WSACC Sewer Ali'ocation and Commitment Policy. Please note that the final comn1iment to seriIice to proe wastewater treatment services strait occur upon application for a building pertnii for tine project and when system development fees are paid pursuant to N.C.G. : §1 b2A, Article 8. If you have. any questions, please call me at (704) 788-4164, extension 104, 1_ Thomas Hahn, PE Utility Systems Engineer cc: Misty Lippard, PFiK.annapo'iiis Wilmer tvlelton'Kannapolis Elizabeth t-1. Hassenfritz, PE/Kannapolis vtichsel Wilson:/WSACC Chad VonCannon, PE/WSACC Mark Lomax/WSACC Division of Water Resources State of North Carolina Department of Environtnental Quality Division of Water Resources Flow Trackin ceptance for Sewer Extension Applications (FTSE —04/16) (WSACC USE ONLY) Crescent Street Water and Sewer Improvement Section 1. Name of wastewater treatment facility (WWTF) receiving wastewater: Rocky River Wastewater Treatment Facility — Permit #NC0036269 [1] Muddy Creek Wastewater Treatment Facility Permit #NC008162i. WWTP facility's permitted flow, MGD Estimated obligated flow not yet tributary to the WWTP, MGD WWTP facility's actual avg, daily flow, MGD Total flow for this specific request, MGD 26,500 2.069 20.0'70 (75.74% .of perrniQ 0,003 Total actual and obligated flows to the facility, MGD 22.142 Percent of permitted flow used 83.55% Section II. Pump stations along the route from the Jurisdiction's connection point to the WWTP. i (A) Pump Station 1 Firm Capacity * Design Average Daily blow ** (Name Of Number) MGD (Firrnipi) NIG° (B.) (C) I (1.)) = (B+C.)! Approx., Current Obligated, Not Yet Total Covent Flow Average .Daily Flow Tributary Daily flow Plus Obligated Pow MGD MGD MG!) . „ .11 n945 41495 12,440 The Firm Capacity of any pump ainn Is defined as the maxiinurn pumped floss that tan be achieved with the largest pump taken out of service, .''Denign Average Daily Flow is the firm capacity of the pump station divided by a peaking factor not less than 25. Flanainp, Assessment Addendum shall be attached for each pump station located bass een the project connection point and the WWTP re Available Capacity is < U. i (E)-0-D} Available Cacactiy'" • I Section III. WSACC Certification Staterne t: 1,1, Thomas Hahn, PE„ certify to the best of my knowledge that the addition of the volume of wastewater to be permitted n this project has been evaluated along the route from the connection to the WSACC interceptor to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the .plaiming assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Section 1 and Section II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates 'WSACC's guarantee of capacity for this wastewater flow. Notwithstanding the guarantee ,of capacity, WSACC does not make a commitment to service this wastewater flow until a building permit is requested through the Cabarrus County Building Inspections Department and WSACC receives payment of the System Development Fee. 7's 'Signing Official Signature D .,e RState of North Carolina Department of Environment and Natural Resources Division of Water Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE —01/14) (JURISDICTION USE ONLY) Jurisdiction Requesting Flow Acceptance for Collection System: City of Concord EiCity of Kannapolis ElTown of Harrisburg EiTown of Mt. Pleasant ECharlotte Mecklenburg Utilities Project Title, Description, and Number of Lots/Unit: Project Title: Crescent Street Water and Sewer Improvement Description: The Crescent Street Water and Sewer Improvementengineering plans and specifications, as prepared and sealed by Elizabeth H Hassenfrit4 NCPE, with City of Kannapolis, for the wastewater collection system extension consisting of approximately 246 linear, feet of 8-inch sanitary sewer with I manholes and other appurtenances to serve 7 located off/on of Crescent Street, with a wastewater discharge of 2,520 GPD. What is the quantity of flow that will be discharged? 2,520 GPI) Flow type: Domestic 100 % [1 Commercial % [1] Industrial Section 1 - List the Jurisdiction's pump stations located between the project connection point and the WSACC Interceptor connection point. Primp Station (Name or Nwnber) irtn Capacity * MGD (A) -esign Average Daily Flow ** (Finn/pf) MGD (13) Approx.. Current Average Daily Flow MGD (C) Obligated, Not Yet Itibutswy Daily Noir NIGD (D) = (B+C) Total Current Flow Obligated Flow MGD (E)',(A-D) Available Capacity". s MGD * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out cif service. ...Design Average Daily Flaw is the firm capacity of the pump 3ratiou divided by a peaking factor not less thar, 2.3. "“A Planning Assessment Addendum shall be attached for each [pump station located between the project connection point and die W1VTP where Availa Sectionll. Jurisdiction's Certification Statement: , Wilmer Melton. iIIJirector ofPublic Works, certify that, to the best of my knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving WSACC interceptor; and the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden on any downstream pump station in route to the receiving WSACC interceptor normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Section 1plus all attached planning assessment addendums for which, to the best of my knowledge, will not adversely affect thejjxtreapi sewer capacity.re of this form indicates acceptance of this wastewater flow. 3 5 ? Jurisdiction'S Signing Official Signature Date Revision Date: 08/09/13 WASTEWATER FLOW ACCEPTANCE FORM FOR THE WATER AND SEWER AUTHORITY OF CABARRUS COUNTY Jurisdiction Requesting Flow Acceptance: City of Concord City of Ka.nnapolis Town of :Harrisburg EjTown of Mt. Pleasant OCharlotte Mecklenburg Utilities Project Title, Description, and Number of Lots/Unit: Project Title: Crescent Street Water and Sewer Improvement Description: The Crescent Street Water and Sewer Improvement engineering plans and specifications, as prepared and sealed by Elizabeth 11... Hassenfritz, NCPE, with City of Kannapolis, for the wastewater collection system exten.sion consisting of approximately 246 linear feet of 8-inch sanitary sewer with I. manholes and other appurtenances to serve 7 lots located ofTron of Crescent Street, with a wastewater discharge of 2,520 GPD, *Number of Lots: 7 OR *Number of Units: *Must be included in request, Where will the new line be connected; Ei Directly into a WSACC Interceptor into the Jurisdiction's existing collection system LI Into a private line Describe the location of the tie-in line to which the new sewer line will connect: T o osed 8-inch sa.nita, sewer extension will tie-in to the existing 8-inc,h san'tflse%tr systemjvhtch extends to the 48 mch RCP material . 'SACC Irish Buffalo Creek Interceptor Which WSACC interceptor will the flow ultimately be discharged into: 4, inch - RCP WSACC lrish Buffalo Creek Interceptor What is the WSACC manhole number that the flow will be discharged into? Manhole No, 01.1173 What is the quantity of flow that will be discharged? 2.520 GPD Flow type: Domes 100 % El Commercial °./0 El Industrial Date: 03/05/2019 Name of wastewater treatment facility (WWTF) receiving wastewater: Rocky River Wastewater Treatment Facility — Permit tiNC0036269 Muddy Creek Wastewater Treatment Facility — Permit #NC00811621 Design drawings of new lines will be submitted to WSACC with the request for acceptance. Drawings can he submitted as a digital file (DWG) or distance and bearing starting with the tap on existing infrastructure, If the new line is to connect directly into a WSACC interceptor, detailed drawings including specification ofthe tap. will be required before flow acceptance will be provided. Mark Lomax at 704-786-1783, ext 2.31, mustbe notified 48 hours in advance of a connection into a WSACC interceptor. WSA.CC will inspect connection before, during, and after completion. If construction is run started within two (2) year from the date of approval of the flow acceptance for this project, the approval is rescinded and a second request and approval will be required Or the project. WSACC USE ONLY: DATE: EII Current sewer model shows an Inierceptor as being surcharged south of the manhole in question, LJ Approved Not. Approved [1 Current Sewer Model shows: E-2 APPENDIX E KA N NAP P11IL I"- or .s March 12, 2019 North Carolina Department of Environmental Quality Mooresville Regional Office - Water Quality Section 610 East Center Avenue, Suite 301 Mooresville, North Carolina 28115 Re: Crescent Street Water and Sewer Improvements Sewer Extension City of Kannapolis — Cabarrus County Dear Sir or Madam: Please find attached for your review and approval the original and one copy of the permit application along with the $480 processing fee for the above referenced project. Also enclosed is the flow acceptance letter from the Water & Sewer Authority of Cabarrus County stating they will accept and treat the additional wastewater at the Rocky River Regional Wastewater Treatment Plant. The proposed extension will connect to the existing Kannapolis sewer system which extends to the WSACC Irish Buffalo Creek Interceptor. This proposed wastewater collection system will replace an existing private system on Crescent Street that was installed by a resident. The Water and Sewer Authority of Cabarrus County Standard Specifications for Wastewater Collections Systems were approved by your office and are being maintained by the Division of Environmental Management. This project will be installed in accordance with these Standard Specifications. Please call me at 704-920-4235 if you have any questions. Sincerely, ID r Beth Hassenfritz, PE rl..1.BLIC WORKS 401 LAURFATE WAY KANN/11°011S. N.(2, 28081 704-920-1;200 WWW KANNAPO L IS NC.GOV