Loading...
HomeMy WebLinkAboutWQ0032114_Regional Office Historical File Pre 2018Michael F Easley, Governor William G. Ross Jr., Secretary North Carolina Department nf1,,:nvironment. and Natural Rz.sourees Coleen Fl. Sullins, .ftrector Div Ision of Water (,?uality August 24, 2007 Mr. Troy Barnhardt, Mayor Town of Mount Pleasant PO Box 787 Mount Pleasant, NC 28124 Subject: Permit No, WQ0032114 Beckenham Subdivision Wastewater Collection System Extension Cabarrus County, North Carolina Dear Mr, Barnhardt, In accordance with your application received on August 2, 2007, we are forwarding herewith Permit No. WQ0032114, dated August 24, 2007 to the town of Mount Pleasant for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein, This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable, 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein, Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville RegionalOffice 61.0 East Center Ave., Suite 301 Mooresville, NC 281.15 Internet: www,ncrnwaterquality ory Customer Service: 1-877-623-6748 „An Equal Opportunity/Alfirrnatwe Action Employer — 50% Recycled/10% Post Consumer Paper Phone, (704) 663-.1699 Fax: (704) 663-6040 (hvt NorthCarollna Aaturally Mr, Barnhardt Page 2 August 24, 2007 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 1,300 linear feet of 8-inch gravity sewer and the discharge of 7,200 gallons per day of collected domestic wastewater into the ater and Sewer Authority of Cabarrus County existing sewerage system, pursuant to the application received August 2, 2007, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Water and Sewer Authority of Cabarrus County WWTP (Rocky River NPDES No. NC0036269) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 1508 of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699, Sincerely, -t 6 1: Coleen H. Sullins cc: Mooresville Regional Office, Collection System Permits Dale Fink, Northeast Engineering, PA Surface Water Protection Central Files Tom Asenzo, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1, This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein, 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T 0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B ,0200 b. A map of the sewer system shall be developed and shall be actively maintained, c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week, e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f A general observation of the entire sewer system shall be conducted at least once per year, g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C, 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5 Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State 6, Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form, A complete certification is one where the form is fully executed and the supporting documents are provided as applicable, 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit: 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B ,0200 and 15A NCAC 2H ,0500. 11, Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc. or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility, Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report, Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300, Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence, This report shall outline the actions taken or proposed to ensure that the problem does not recur, Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 24th day of August, 2007. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSlON r Ccleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0032114 Fast Track Engineering Certification Permit No, WQ0032114 August 24, 2007 0wneriWQCS Town of Mount Pleasant Troy Barnhardt, Mayor PO Box 787 Mount Pleasant, NC 28124 WQCSNVWTP WSACC Thomas Bach, UtW System Eng. PO Box 428 Concord, NC 28026 PE Dale Fink NorthEast Engineering, PA PO Box 931 Concord, NC 28026 Complete and submit this form to the permit issuing regional office with the following, • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater col ection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form: Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division, ENGINEER'S CERTIFICATION Partial I Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (0 periodically, El weekly, LJ full time) the construction of Beckenham Subdivision, a Cabarrus County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit: 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials, North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineers Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. FAST -TRACK APPLICATION fur GRAVITY SEWERS, PUMP STATIONS, D FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! z • 111 Troy Barnhardt, Ma o , Town of Mt, Pleasant Signing Official Name and Title (Please review 1 5A NCAC 2H ,0206(b) for authorized signing officials!) 2• lc. The legal entity who will own this system is: Ce Individual D Federal Municipality El State/County Private Partnership 0 Corporation Other (specify): Application Number: (to be completed by DWQ) 1. Owner: la. Town of Mt. Pleasant Full Legal Name (company, municipality, HOA, utility, etc,) O ld, PO Box 787 LL Mailing Address if. NC State O th, 704-436-9800 szE Telephone Facsimile () 2. Project (Facility) Information, —i 2a, Beckenham Subdivision • Brief Project Name (permit will refer to this name) Ci. < 3. Contact Person: 4 3a,, Matt Weiss, Project Engineer Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 704-788-6372 3c. mweis nee- a le. Mt. Pleasant City lg, 28124 Zip Code 1j, E-mll Cabarrus 0 cc 0 u. th County Where Project is Located Phone Number E-mail 1, Project is New E] Modification (of an existing permit) If Modification, Permit No: For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2, Owner is Public (skip to Item 8(3)) El Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one) Retaining Ownership (i,e. store, church, single office, etc,) or Ej Leasing units (lots, townhomes, etc. - skip to Item 8(3)) 0 Selling units (lots, townhomes, etc, - go to Item B(2b)) 3. WSACC El Public Utility (instruction III) Ej Homeowner Assoc./Developer (Instruction IV) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a, Rocky River WWTP 4b. NC0036269 Name of WWTF WWTF Permit No, 5a, Mt. Pleasant 5b. 8" Gravity 5c. Owner of Downstream Sewer Receiving Sewer Size 0 Force Main 6. The origin of this wastewater is (check all that apply): Residential Subdivision • Apartments/Condominiums • Mobile Home Park r] School • Restaurant LI Office n Car Wash 0 Institution El Hospital Ej Church 0 Nursing Horne El Other (specify): Permit Number of Downstream Sewer (if known) % Domestic/Commercial % Industrial % Other (specify): 7. Volume of wastewater to be allocated for this particular project: 7200,gallons per day *Do not include previously permitted allocations 8. If the permitted flow is zero, indicate why: Interceptor Line - Flow will be permitted in subsequent permits that connect to this line O Flow has already been allocated in Permit No. Rehabilitation or replacement of existing sewer with no new flow expected FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 z F- z 0 z 0 2 0 z 9, Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H ,0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below, Values other than that in 15A NCAC 2H .0219(1)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H 0219(1)(3). 360 gallons per day, 20 3 bedroom homes 10, Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 8 Gravity or Force Main (use the pull down menu) 1,300.47 Gravity ENTER TOTAL LINE LENGTH IN MILES 0 246 ary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator %OATS; 3- plans for cross-reference) (MGD) GPM @ TDH portable generator witelemetry; 4-wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? w Yes E] No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION CO 13, Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? El Yes El No N/A Sedimentation and Erosion Control Plan? Yes LJ No E1 N/A tzg N/A Storrnwater LIJ Yes Ej No 14„ Does this project involve aerial lines or siphons? Check if yes:LI These lines will be considered high priority and must be checked once every six months 15. Does this project have gravity sewer lines designed at minimum slopes? El Be aware that the Division wilt not accept installed lines more than 10% flatter than the minimum slope. Lines installed outside this tolerance should be corrected orior to submitting the final engineering certification. FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PACE 5 1, Use the Division's guidance document entitled, "DETERM NING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality Z regional office (see instructions for addresses) OR indicate the following: 0 El A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope i... waterbody, AND, 0 0 A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. 2 w co 0 Location ID on Map (seit chosen - as shown on Name of Waterbody Stream Waterbody map for cross-reference) Waterbody County River Basin Index Classification As Shown McAllister Creek Cabanas Yadkin 13-17-11-7-1 C Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! 1. Applicant's Certification: 1, Troy Barnhardt, Mayor Town of Mt. Pleasant, attest that this application for Beckenham Subdivision has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. el Signe u 2, Professional Engineer's Certification. I R. Dale Fink, PE, PLS attest that this application for Beckenham Subdivision has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design, Note. In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation. 7-1/42- 2a. R. Dale Fink, PE, PLS Professional Engineer Name 2b. NorthEast Engineering, PA Engineering Firm 2c. PO Box 931 Mailing Address 2d. Concord City 2e. NC 2f. 28026-0 State Zip 2g. .704-788-6372 2h. 704-786-4750 2i. dfink@nee-pa.com Telephone Facsimile E-mail Date Seal, Signature & Date Par Number 0 21 4 rai File BPS SwaP 08 2 l07 Permmit racking Slip Program ate ory Non -discharge Permit Type Gravity Sewer Extension Pump Stations: Extensions Primary Reviewer dee.browder Permitted Flow 7200 facility Facility Name Beckenham Subdivision Location Address Owner Owner Name Town of Mount Pie Pressure Sewer Clots s/ v nit Scheduled Orig Issue App Received Ora lrartiatett ssuance 0 t23 07 0 /02/07 Regulated Activities Sub ivisdon toww a tttfall Waterbody Name n cam Status-- Active Project Type New Project Version Permit bias&fication 1.00 Individual Permit Contact Affiliation Major/ Region Minor Mooresville County Cabarrus Facility Contact Affiliation Owner Type Government = Municipal Owner Affiliatioi Troy Barnhardt, Maycar Phi Box,7` Mount Pleasant NC 2 12 0787 Public Notice Issue Effective 0 /2 r07 0 /2 /07 eceived verity Aadcrit`sonal inform akersn requested irddi6ttrnal inforriiafron rr emmvec dGx Number Non Current Clasp Subbasin AY ) THE RDER McDONALD HOMES INC. 4575 HW'r' 49 NORTH CONCORD, NC 28025 c,D FIRST CHARTER MOUNT PLEASANT, NORTH CAROLINA 28124 66-73-531 7 DATE 10448 AMOUNT 00,63C) 5 .000 rn-s.1-.81116 I:053 L007371: 0 0082970 ATER & SEWER AUTHORITY OF CABARRUS COUNTY The Flonorable Troy W. Ban Town of Mt. Pleasant P. O. Box 787 Mt. Pleasant, NC 281 24 a July 26, 2007 Subject: Flow Acceptance Beckenham Subdisision (20 Lots) 0884.3 232 0.8334308 H338, Concord, NC 28027 Ntdd 18) Ea 888 428 Concord, NC 28026-0428 Phone: 704.7 MA 783 Fdd, 704.7951564 Dear Mayor Barnhardt: This is in response to the Town's request .for flow acceptance received July 9. 2007. The Water and Sewer Authority of Cabarrus County (WSACC) has or currently expects to be able to make available capacity at the Rocky River Regional 'Wastewater 'Treatment Planand appropriate sewer interceptors to transport and treat the domestic wastewater from the proposed -project. The wastewater generated by this project will be conveyed through the Town of :Mt. Pleasant's proposed -inch gravity system, and then through an existing pump station located in Fieldstone Subdivision, and then enters WSACC'S system at the existing 8-inch force main located along Cold Springs Road. WSACC agrees to accept wastewater from the proposed Beckenham Subdivision. which will include 20 single family residential lots. This is based on information provided by Northeast Engineering (Ovil Engineer for the project) using North Carolina Department of Environment. and Natural Resources (NCDENR) wastewater flow guidelines. The projected flow is 7.200 gpd; however, WSACC expects the actual wastewater flow to more closely approximate 5,000 gpd based upon Master Plan engineering data. By requesting flow acceptance, the Town of Mt. Pleasant acknowledges that WSACC may need to upgrade, expand, or construct new facilities to acconun.odate the increased flow volume granted by this and previous flow acceptance. Appropriate design and construction will be initiated \\then a.ctual flows dictate but may be subject to situations that WSACC does not expect or control. Based upon flow of 7,200 gpd and cost of $8.126/gpdto provide treatment and transportation capacity, this flow acceptance represents an estimated capital expenditure in excess of $58,507. For your information and based upon. NCDENR. wastewater flow guidelines, WSAC(' has approved 10E410 gallons of flow acceptance for the Town of Mt. Pleasant from 1992 to present and 7,200 gallons of flow acceptance year-to-date including this request. Based upon the approved flow acceptances. WSACC has committed capacity valued in excess of $824,058 for the Town of Mt. Pleasant since 1992 including $58,507 for this calendar year. Downstream facilities from the proposed project are scheduled in WSACC's current Capital Improvement Program (CIP) to increase .available capacity. Projects on the CIP are subject to approval by WSACC's Board of Directors, support from local governing bodies, regulatory Town of Mt. Pleasant Beckenham Subdivision (20 Lots) July 26, 2007 -Page 2 approval, and funding availability. 'The following schedule of CIP projects is tentative and may be delayed by unforeseen circumstances: Mt. Pleasant Transmission Upgrade — 12" Force Main. Scheduled conipletion date: 2019 If construction of this project is not started within to (2') years of the date of this approval, the approval is rescinded and a second request and approval will be required. Please notify WSACC, in Wri t ing, when construction of this project is initiated. If you have any questions, please call me at 704-786-1783. Sincere! y, eete4 cc WSACC Engineering Staff Thomas A. Bach, RE. titilitjj S) stems Engineer Mark Lambert, P,E./Frazier Engineering 1)ale 1 P.EkNortheast Engineering TopoZone - VJSGS Mount Pleasant (ETC) North Carolina Topo 0 0.3 0.6 0.9 1.2 1.5 km 0 0.1 0.2 0.4 0.5 mi UTM 17 546035E 3914634N (NAD27) USGS Mount Pleasant (NC) Quadrangle Projection is UTM Zone 17 NAD83 Datum M=. 7.41 G=0 . 2`34 Page 1 of 1 http:/iw r.topozone.comiprnnt.asp tat-35.37576&1on=-80.4932 s=48&u=4&layer=DRG&datum=nad27 7/10/2007 Tot ne - I.JSGS Mount Pleasant (NC) North Carolina Topo Page I of .1 0 0.3 0.6 i .9 1,.2 1.5 km 0 0.1 0.2 0.3 0.4 0.5 ma UTM 17 546035E 3914634N (NAD27) USGS Mount Pleasant (NC) Quadrangle Projection is UTM Zone 17 NAD83 Datum http://w-ww.topozone.com/print.asp?lat=35.37576&Ion=-80.4932 ;:,s=48&u=4c is per=DI G► datun =nad27 711.0/2007 NORTHEAST ENGINEERING kr<w engineering with oh fends a LETTER OF TRANSMITTAL To: NCDENR We are sending you: Copies Date 86` l a't 7 8/ I /07' 4t k A Northeast Engineering, P.A. 37 S Union St. Suite D P.O. Box 931 Concord, North Carolina 28026-0931 Phone: 704-788-NEPA PA (6372) Fax 704-786-4'750 www.nee-pa corn Date: 8/ I /2007 Attention: Re: Description C car' ipmval' Remarks: 8/I/07 8/ 1 /07 0 As Requested ptance letter from WSACC Ps 0 For Review and Comment For Your U Please call if you have any questions or require additional information. Thanks Matt Weiss Copy To: If enclosures ar Signed: not as noted above, please cinttct us immedia Y-