Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0031078_Regional Office Historical File Pre 2018
Mr, Wilmer Melton, Dir. Of Public Works City of Kannapolis 1401 Bethpage Road Kannapolis, NC 28081 Michae nor William G. Ross Jr,, Secretary North Carolina Department ok rawircrourrtent and Natural Resources Alan W. KIirn k, P.E. Director Division. of Wafter Quality December 12, 2006 Subject. Permit No, WQ0031078 Pelham Pointe Subdivision City of Kannapolis Wastewater Collection System Extension Cabarrus County, North Carolina Dear Mr, Melton, In accordance with your application received on November 9, 2006, we are forwarding herewith Permit No. WQ0031078, dated December 12, 2006, to the City of Kannapolis for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference, Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T 0403 or any individual system -wide collection system permit issued to the Permittee, Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules, Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board, Mooresville Regional Office 610 East Center Ave , quite 30J Mooresvi91e, NC 28115 Phone Internet www,ncmwaterqual4y,org Customer Service:: 9-877-623-6748 An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper 704 03-1699 Fax: (704) 663-6040 Onc Nprt hCart ina r. PIF Melton Page 2 December 12, 2006 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Kannapolis for the construction and operation of approximately 4,936 linear feet of 8-inch gravity sewer and the discharge of 40,680 gallons per day of collected domestic wastewater into the City of Kannapolis existing sewerage system, pursuant to the application received November 9, 2006, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Water and Sewer Authority of Cabarrus County WVVTP (Rocky River NPDES No. NC0036269) prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714, Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Dee Browder at (704) 663-1699, Since n- Alan W. Klimek, P,E, cc: Mooresville Regional Office, Surface Water Protection (WWTP Permit No. NC0036269) Paul Campbell, NorthEast Engineering Mike Cassarino, Pelham Point Development, LLC Surface Water Protection Central Files Tom Asenzo, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T ,0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 21._ .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained, c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by docurnentation from, the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6, Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable, 7, A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable: the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215,6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities, 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 28 .0200 and 15A NCAC 2H ,0500, 11, Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number () - or (919) -. Persons reporting any of the above occurrences shall file a spill report by completing Part 1 of Form - (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 1 of Form CS-SSO(or the most current Division approved form) can also be completed to show that the SSO was beyond control, Permit issued this the t.th day of December, 2006. NORTH CAROLINA ENVIRONMENTAL MANAGEI ,for Alan VV. Klimek, RE, Dire for Division of Water Quality By Authority of the EnvironmentalManagemente en Commiscion ENT Cot Perm umber WQ0031078 1 ON Fast Track Engineering Certification • Permit No, WQ0031078 December 12, 2006 Wilmer Melton, Dir. Of PW 1401 Bethpage Rd. Kannapolis, NC 28081 Complete and submit this form to the permit issuing re onal office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are reured for anvhanges resultnQ in nori comphance wth thise ulations or This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division, ENGINEER'S CERTIFICATION Partial 0 Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (El periodically, El weekly, 11 full time) the construction of Pelham Pointe Subdivision, a Cabarrus County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable: the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials, North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. AtK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner: 1a. City of Kannapol%s Full Legal Name (company, municipality, HOA, utility, etc,) 1b, Wilmer Melton, III - Director of Public Works Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing offrcialsl) The legal entity who will own this system is: ❑ Individual ❑ Federal ' Municipality 0 State/County 0 Private Partnership ❑ Corporation ❑ Other (specify): Application Number: (to be completed by DWQ PAGE 3 1 d. 1401 Bethpage Rd. O Mailing Address 0 NC State 1 h. 704-920-4200 'i i. 704-920-4244 Telephone Facsimile 2. Project (Facility) Information:: 2a, Pelhem Pointe Subdivision Brief Project Name (permit will refer to this name) Contact Person: 3a, Paul Campbell, NorthEast Engineering, PA 1 e. Kannapolis City 1g, 28081 Zip Code wmelton@ci kannapolis.nc.us E-mail 2b. Cabarrus County Where Project is Located Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 704-788-6372 Phone Number 3c. ocannobeii nee mmt a E-mail Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is Public (skip to item 8(3)) 0 Private (go to item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one O Retaining Ownership (Le. store, church, single office, etc.) 0 Leasing units (lots, townhomes, etc. - skip to Item 8(3)) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) Water & Sewer Authority of Cabarrus Coun Public Utility (Instruction III) ❑ Homeowner Assoc./Develope Owner of Wastewater Treatment Facility (WWTF) Treating' Wastewater From This Project 4a. Rocky River Regional Wastewater Treatment Plant 4b.. ,.__M.. NC©©36269 Name of WWTF Z 5a, WSACC 15b. 36 Gravity fic Owner of Downstream Sewer jReceiving Sewer Size ❑ Force Main The origin of this wastewater is (check all that apply):. ® Residential Subdivision ❑ Apartments/Condominiums 0 Mobile Home Park School 0 Restaurant Ej Office 0 Car Wash O Institution 0 Hospital 0 Church O Nursing Home • Other (specify): WWTF Permit No. ns ction IV) Permit Number of Downstream Sewer (if known) 1 QQ % Domestic/Commercial % Industrial % Other (specify): 7. Volume of wastewater to be allocated for this particular project: 40.680 gallons per day *Do not include previously permitted allocations 8. If the permitted flow is zero, indicate why: ❑ interceptor Line - Flow will be permitted in subsequent permits that connect to this line • Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected I"TA 02/03 - Revd 3 04/05 ACIC APPLICATION for GRAVITY SEWERS, PUMP STATIONS, ANit FORCE MAINS PAGE4 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(I) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(I)(3). 113lots at 360 gpd per lot 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Length (feet) 4936* Size (inches) 0 ENTER TOTAL LINE LENGTH IN MILES 0.93 z 0 ummary of Pump Stations to be Permitted (attach additional sheets as necessary) Gravity or Force Main (use the pull down menu) Location ID Power Reliability Option (self chosen - as shown on ' Design Flow Operational Point (1- dual line feed; 2- permanent generator w/ATS; 3- plans for cross-reference) (MGD) GPM t TDH portable generator w/telemetry; 4-wet well storage) 2. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H ,0200 as applicable? Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permitslcertifica'tions been submitted for approval Wetland/Stream Crossings - General Permit or 401 Certification? Yes ❑ No ❑ N/A Sedimentation and Erosion Control Plan? Stormwater? 14. Does this project involve aerial lines or siphons? ❑ These lines will be considered high priority and must be checked once every six months Yes El No ❑N/A El Yes ❑ No l N/A FTA 02/03 - Rev. 3 04/05 ACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 1, Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary), This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: 0 A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, 0 A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on Name of Waterbody Stream Waterbody map for cross-reference) Waterbody County River Basin Index Classification WSACC MH 011810 Rocky River Cabarrus Yadkin 13-17 C Submit the 115" x 11" COLOR topographic map as required in Instruction VI -- regardless of whether a classification is provided! Applicant's Certification: 1, Wilmer Melton, Dir, Public Works, attest that this application for Pelhem Pointe subdivision has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete, Notes In accordance with North Carolina General Statutes 143-215,6A and 143-215,68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. la, Signing Official Signature co 2. Professional Engineer's Certificationz 0 Date I attest that this application for Pelhem Pointe Subdivision has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and ail other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that/ have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation. 2a. Paul Campbell Professional Engineer Name 2b, NorthEast Engineering Engineering Firm 2e. PO Box 931 Mailing Address 2d, Concord 2e. NC 2f, 28026 State Zip 2h. 704-786-4750 2i, pc,ampbell©nee-pa.corn City 2g. 704-788- 6372 Facsimile E-mail SEAL 18908 CA /nut Seal, Signature & Date FTA 02/03 - Rev. 3 04/05 the GS Kannapolis APS C, Topo Map GET DATA New Product Download every Topo and Aerial at this location $9.95 Get Your MapP ck Now Map and Photo Info i ra nloid Se are mess Y""t pos DQwnkmd Sc 3rniesr, Photos USGS Topo Maps 1:24K/25K Topa Maps 1:100K Topo Maps 1:250K Topo Maps Automatic selection Map Size mall edium e View Scale 1 : 25,000 Coordinate Format UTM Map Datum NA©8311NGS84 _. Show target Email thus tupu rrtai) Bookmark tN,s, r:nrn— map Print this t Crnstt ction Calc Real Estate Calculators, OPO E Page 1 of 2 rs - Construction, Electrical, and EngineerSuppiy.corn tCES UT USGS Kannapolis (NC) Top° View ropo?onero Promo topographic maps, aerial photos, street m UTM 17 523076E 3922434N (NAD8 iata r. , aVoN at 0.3 0.2 0.4 0.9 0.6 http://www.topozone.com1map.asp?1at-3 4451 &ion=-80.74573 s=25c" size=1&symshow.,. 9125/2006 KANNAPOL IS November 6, 2006 NC Div of Environmental Management Department of Environment and Natural Resources — Division of Water Quality 610 East Center Drive, Suite 301 Mooresville, North Carolina, 281,15 Re: Pelhem Pointe Sewer Extension City of Kannapolis Cabarrus County Dear Sir or Madam: 045 1-67 Please find attached for your review and approval the original and one copy of the permit application and a check for S400.00 for the processing fee for the above reference project, Also enclosed is the flow acceptance letter from. the Water & Sewer Authority of Cabarrus County stating they will accept and treat the additional wastewater at the Rocky River Regional Wastewater Treatment Plant, The Water and Sewer Authority of Cabarrus County Standard Specifications for Wastewater Collections Systems were approved by your office and are being maintained by the Division of Environmental Management. This project will be installed in accordance with these Standard Specifications. Please call me at 704-9381519 if you have any questions. Sincerely, Stephen J. Bissinger, PE Assistant City Engineer 04501.67 Pelhem sewer permit letteridoc NOV Cr TY 1) 1'1 K A N N Engineering Depart I1 T 70,t938,11519 PC), Box '1248 'Ka nnapolis„ NC 28082-1218 120 S. Main 81, Ka nnapolis, NC 28081 A 0 0 L 1 S 1: 704.938 6810 Central Files: APS Permit umber 078 Permit Tracking Slip 12 2106 Program Category Non -discharge Status Project Type In review New Project Permit Type Fast Track Version Permit classification Gravity SewerExtension, Pump StetStations Pressure Sewer A Individual Extensions Primary Reviewer dee.browder Permitted Flow 40680 Permit Contact AtfUi tian Facility Name Pelham Palate t o cation Address Owner Owner Name City of tnnapclis Pates/Evon ar/Mlrrr Region nor Mooresville County Cabarrus contact Affiliation Owner Type Government - Mon icipal inter Affiliation Melvin Rape, PE PO Box 1199 Kannapolis NC 81111 Scheduled r►g Issue App Recelued Draft Initiated Issuance Public Notice issue Effective Expire on 11 /091006 Re Activities the v sion steel Iv Additional information ro bested Wastewater cone Additional information received utfali NUL rbody Name nts Index Number Current class subbasin PELHEM POINTE DEVELOPMENT, LLC. 11920 CUPWORTH CT. HUNTERSVILLE, N.G. 28078 FIRST CHARTER wa odirstcharier.ccm 66- /531 100 0010 6 **,k****************),************4******- rour hundred dollars and no cents N0DENR November 7, 2006 $*******'*40000 11.00101E11' ':0S 007317031.20290 Fax . 704 7 951564 Nov 6 2006 11 24 P. 04 WATER & SEWER AUTHORITY OF CABARRUS COUNTY November 6, 2006 Mr, Michael Legg City Manager City of Kannapolis PO Box 1199 Kannapolis, NC 28082-1199 Subject: Flow Acceptance Pelhem Pointe Subdivision 212 Rovidy)n 14wy, C'onroFl1, NC 28017 Ma b' P.O Sox 29 (;oncurd, tiC 28026•0428 704 7B6.1783 4 Dear Mr. Legg: This is in response to the City's request for flow acceptance received 10/10/06. The Water and, Sewer Authority of Cabarrus County (WSACC) has or currently expects to be able to make available capacity at the Rocky River Regional Wastewater Treatment Plant and appropriate sewer interceptors to transport and treat the wastewater from the proposed project. WSACC agrees to accept wastewater from the proposed Pelhem Pointe Subdivision, which will consist of 11.3 single family residential lots. This is based on the information provided by Northeast Engineering (Engineer for the Project) using North Carolina Department of Environment and Natural Resources (NCDENR) wastewater flow guidelines. The projected flow is 40,680 gpd; however WSACC expects the actual wastewater flow to more closely approximate 28,250 gpd based upon Master Plan engineering data. By requesting flow acceptance, the City of Kannapolis acknowledges that WSACC may need to upgrade, expand, or construct new facilities to accommodate the increased flow volume granted by this and previous flow acceptance. Appropriate design and construction will be initiated when actual flows dictate but may be subject to situations that WSACC does not expect or control. Based upon flow of 40,680 gpd and cost of S8.126/gpd to provide treatment and transportation capacity, this flow acceptance represents an estimated capital expenditure in excess of S330,566. For your information and based upon NCDENR wastewater flow guidelines, WSACC has approved 2,810,267 gallons of flow acceptance for the City of Kannapolis from 1992 to present and 386,797 gallons of flow acceptance year-to-date including this request. Based upon the approved flow acceptances, WSACC has committed capacity valued in excess of S22,836,230 for the City of Kannapolis since 1992 including 33,143,112 for this calendar year. Downstream facilities from the proposed project are scheduled in WSACC's current six year Capital Improvement Program (CIP) to increase available capacity, Projects on the CIP are subject to approval by WSACC's Board of Directors, support from local governing bodies, regulatory approval, and funding availability The following schedule of CIP projects is tentative and may be delayed by unforeseen circumstances. Kin Grant Rocky River Parallel Interceptor. SQlicdulcd ccrinplcta+ rs date: 2010 Fax ' 4 51564 Nov 6 06 11:24 Cif of Kannapolis Pethem Pointe Subdiv'isson November 6, 2006 Page 2 of Since this sewer roan non ill be made directly to the WSACC 36" Rocky Weer Interceptor, WSACC must be notified 48 hours prior to connection tieing made. Notification. is to be made to Mark Lomax 7044864783. 1t should be noted that the existing manhole where the connection of the proposed " gravity sewer from the Pethem Pointe Subdivision development is located has a T-Manhole type base, "Therefore, this flow eptance is granted with the condition n that the Engineer and/or the contractor coordinate the exactmanhole coring location with Mark Lomax, Please note that if construction of this project i not started 'ithin two (2) ye of the date of this approval, the approval is rescinded and a second request and approval will be required. Please notify WSACC, in writing, when construction of this project is initiated: If you have any questions, please call me at 704-786-1783, Thomas A. Bach, P.E. Utility Systems Engineers WSACC Engine rinStaff Jeff Mo dy, PE./Karmaptalis City Engineer Wilmer I' eltoniKannapolis Paul Campbell, P.E ,Northeast En, weerin Michael F. Easley, Governor William G, Ross Jr, Secretary North Carolina Department of Environment and Natural Resources Coleen Sullins, Director Division of Water Quality January 22, 2008 Wilmer Melton City of Kannapolis P.O. Box 1199 Kannapolis, North Carolina 28081 SUBJECT: Pelham Pointe Subdivision Permit No. WQ0031078 Wastewater Collection System Extension Final Engineering Certification Dear Permittee: The Division received a final engineering certification for the subject project on November 2'0, 2007. A full review of the certification materials may or may not be conducted. It is assumed that receipt of this certification indicates compliance with all regulations, design criteria and the permit Please be reminded that the Permittee is responsible for keeping a copy of the final record drawings for the life of the project. If you have not received a copy, please contact your consultant immediately to obtain a copy. You are receiving this letter because the Division has you listed as the responsible party. If this permitted system is no longer owned by you, please complete Form PNOCF-S as this permit is not automatically transferable. Form PNOCF-S can be downloaded from httio://h2o.enr,state.hc,usinctndpuappshtml#Sewer. If you have any questions concerning this document or the completion of Form PNOCF-S necessary), please contact Ms. Dee Browder at the letterhead address or via E-mail at dee.browder@ncmail.net. rely, `7).)Robert Krebs. Surface Water Protection Regional Supervisor Enclosure Cc: Stephen Bissinger, PE, Alley: Williams„ Carmen & King Surface Water Protection Section Central Files {certification page onlyl if One NorthCarolina Naturally Pretreatment, Emergency Response and Collection Systems Unit Internet http:41h2o.enr..n.c,state,usindpu 1617 Mail Service Center, Raleigh, NC .27699-1617 An Equal opportunity Action Employer Telephone (919) 733-5083 Fax (919( 733-0059 50% recycled/10% post-consumerpaper Fast Track Engineering Certification Permit No. W00031078 December 12, 2006 Wilmer Melton, Dir, Of PW 1401 Bethpage Rd, Kannapolis, NC 28081 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and ail required supporting documentation have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Lil Partial V1 Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (iperiodically, El weekly, Ell full time) the construction of Pelham Pointe Subdivision, a Cabarrus County project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable, the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials North Carolina Professional Engineer's seal, signature, and date. SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. Alley, Williams, Carmen & King, Inc. Post Office Box 1248 120 South Main Street Kannapolis, North Carolina 28082-1248 Phone 704/938-1515 Fax 7041938-6810 To: NCDENR Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, NC 28115 WE ARE SENDING YOU THE FOLLOWING:. Letter of Transmittal ❑LISPS ❑U.PS ❑FED -EX ❑oVERNIGH'T ❑HAND DELIVER Date: November 16, 2007 Job No. 04501-67 Attn: Dee Browder Re: Pelherr Pointe- Final 1 Construction Record Drawings Engineer's Certification THESE ARE TRANSMI i I ED as checked below: ❑ For approval For your use 0 As requested ❑ See Remarks Ej Approved as submitted 0 Approved as noted ❑ Returned for corrections NC DEN D Q urface Resubmit Submit 0 Return r Prot copies for approval ❑ For signature copies for distribution corrected prints *are G41.wordltrsl04501 General404531-67 Pe/hem Pointe sewer as built transs.doc