Loading...
HomeMy WebLinkAboutWQ0030786_Regional Office Historical File Pre 2018 (2)Michael F„ Easley, Governor William G. Ross Jr., Secretary North Carolina Deparunent of Environment and Natural Resources Alan W. Klimek, P.E, Director Division of Water Quality September 14, 2006 Mr. Wilmer Melton, III — Public Works Director City of Kannapolis 1401 Bethpage Rd. Kannapolis, North Carolina 28081 Subject Permit No, WQ0030786 Pine Creek Subdivision Phase 5 City of Kannapolis Public Works Wastewater Collection System Extension Cabarrus County, North Carolina Dear Mr, Melton: In accordance with your application received on August 31, 2006, we are forwarding herewith Permit No. WQ0030786, dated September 14, 2006, to the City of Kannapolis Public Works for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein, This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2T; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 61,0 East Center Ave., Suite 301 Mooresville., NC 28115 Internet: www.ncwaterqualily,ortj Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer — 50% Recycledi10% Posl Consumer Paper Phone: (704) 663-1699 Fay(704) 663-6040 Ithcaoltna tuna" =.‘ Mr Witmer Melton Page 2 September 14, 2006 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City Kannapolis Public Works for the construction and operation of approximately 530 linear feet of 8- inch gravity sewer as part of Pine Creek Subdivision Phase 5 project, and the discharge of 5,280 gallons per day of collected domestic wastewater into the City of Kannapolis existing sewerage system, pursuant to the application received August 31, 2006, and in conformity with 15A NCAC 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Rocky River Regional WWTP NPDES No. NC0036269 prior to being discharged into the receiving stream. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit, This request must be in the form of a written petition, conforming to Chapter 1508 of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding, If you need additional information concerning this matter, please contact Samar Bou-Ghazale at (704) 663-1699. Sincerely, (4, for Alan W, Klimek, P.E. cc: Mooresville Regional Office, Surface Water Protection (WWTP Permit No, NC0036269) Jeffery Boone, Greenbrier Group, PC Surface Water Protection Central Files Mina Leach, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2T .0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 28 .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. IT Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 28 .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable, in the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State, Per 15A NCAC 2T .0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the.wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H ,0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch, 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report, Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300, Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 14th day of September, 2006, NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION ,,for Alan W Klimek,(V.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number W00030786 Fast Track EngineeringCertification Permit No. WQ0030786 September 14, 2006 Complete and submit this form to the permit issuing regional office with the following. • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form Permit modifications are required for any changes resulting in non-compliance with this permjJaUons or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEERS CERTIFICATION El Partial E Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (El periodically, [1] weekly, E] full time) the construction of Pine Creek Subdivision Phase 5, a City of Kannapolis project for the Permittee, hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H ,0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineers Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. | / 3U� 704-347-4972 3o.�oonc Phone Number � E-mail 1. ProjectisONew El Modification (of an existing permit) If Modification, Permit No.: � For modifications, attach aseparate sheet clearly explaining the reason for the modification (i/e.adding another ' phase, changing line size0enQth'otcl Only include the modified information in this permit application 'dunot ! duplicate project information in 13(7) and B(1 0-11) that has already been included in the original permit, ,2, Owner is Pubiic (skip to Item B(3)) Private (go to Item 2(a)) ) | ' ' ' El Retaining Ownership (i,e, store, church, single office, etc.) or, n Public Utility (instruction 111) [] Homeowner Asmoo.8]avelope,(instruction IV) -TRACK APPLICATION for GRAVITY SEWERS, Pt, T i%4P STATIONS, AND FORCE NIAINS PAGE USE THE TAB KEY T(JMOVE FROM FIELD TORELDi / Application Number: | (to be c�"����m` . ---� ' -- 4. Owner.,�, 1a. _ ' Full municipality, r ------'--------'- '--------^---' '------ 1b. Wilmer Mellon, III ' Director nfPublic Works Signing Official Name and Title (Please review 15NCAC 2H 0206(b) for - authorized signing---�----officials!) ! '---'---------------- ----------- 1 c, The legal entity who will own this system is: [] |ndividuaf [-1 Federal 0 Mwmickpu|dv Fl Stp1exCoonty E] Private Partnemkip_[:] Corporation [] Other (opecify) �& 1481 Bethpage Rd. 0� �aU��Add�ms U_- ' Z � /NC_ ' State r���--''-- lh� 704�2042O0 1i 7Q4-92�4244 ' Telephone ' Facsimile ' ' oject (Facility) Information: �� �Ze, PINE CREEK SUBDIVISION PHASE 5 10 Kanna is city 510. 28081 Zip Code � 8��Pn�er Name (ponndw0�f�to��name �� - ---i�c�Pmnoun� ° r' ----'--' ----- - 3e, JEFFREYA.BoONE DESIGN ENGINEER ' E-maii 2b. CABARRUS _ F�r_oject -is County Where ocated Name and AffihahanoYSomeoneWho Can Answer Questions About this Application Z' []Leauinq,nNu(lots.lownhomea.etc. ;kip toItem 8(J} El Selling units (lots, townhomes, etc, - go to Item B(2b)) Owner cfVVasewaterTeatmenvFodNy(WVVTF)Trea�ngVVe»�wa1erFmnmThspru�o 4o. ---- i �| Wastewater Treatment Plant— --. NC—�-- 036269 �� / Nome cdVVVYTF � �--- -- -- -- --. Permit No, U. ' / -.._. 8. . � __ Main OwnerdDown�mamReceiving Sewer Size Force m /Permit Number of Downstream Sewer (if kn wn The origin of this wastewater �s (check all that apply): Residential Subdivision Apurime ntn/Condonniniumw Mobile Home Park School El Restaurant P Office 7, Volume ufwastewater ,obaaUocaledfor this particular project� 5.280 gallons per day *Do not include previouslypermitted allocations G. Kthe permitted flow is zero, indicate Interceptor Line - Flow will be permitted in subsequent permits that connect to this line | Flow has already been allocated inPermit No - El Rehabilitation or replacement of existing sewer with no new flow exp,ected enbrierdesign.com bc� - 100 % OnmmsUcxCmnmo,dmi %|nduskio| Car Wash Institution Hospital El Church LJ Nursing Home 0 Other (specify): piT-TRACK APPI.ICAT]0, for GRAVITY SEW R z 0 z P ° TATIONS, AND FORCE MAINS PAGE 4 9. Provide the wastewater flow calculations used in deterrnining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for Vine or pump station sizing if zero flow in the space below, Values other than that in 15A NCAC 2H .0219(I)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(1)(3), LOTS x 4 BDR/LOT x 120 GPDIBDR) = 5,280 GPD 10. Summary of Sewer Lines to be Perry fitted (attach additional sheets if neces Size (inches) Length (feet) ENTER TOTAL LINE LENGTH IN MILES Summary of Pump Stations to be Permitted (attach additional sheets as nece Gravity or Force Main use the pull down menu 530.00 GRAVITY 0,10 MILE 0 Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator wfATS; 3- plans for cross-reference) (MGD) GPM @ TDH portable generator witelemetryi 4-wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force,' Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable?% Yes © No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE. VARIANCE WITH YOUR APPLICATION 13, Have the following permi ions been submitted for approval WetlandiStrr;arn Crossings - General Permit or 401 Certification? © Yes LI No N/A Yes E No Ej NIA Yes El No EJ NIA Sedimentation and Erosion Control Plan? water? 14, Does this projvoly nes or siphons? El NIA These lines will be considered high priority and must he checked once every six months rpy ,,T-TRACK APPLIC4TON for CRAVJT SEWERS, PUMP STATIONS, AND FORCE MAINS. PAGE 5 1, Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary) This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following; A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope water body; AND, A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope water body* Location ID on Map (self chosen - as shown on Name of Waterbody Strea map for cross.reference) Water body County River Basin Index O F16NW5 WEST BR, AFTON CABARRUS YADKIN 13-17-6-6 RUN (YAD11) LU Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! 1. Applicant's Certification: Waterbody Classification 1, Wilmer Melton, Dir. Public Works, attest that this application for PINE CREEK SUBDIVISION PHASE 3 has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. la, 6—P3i25. Signing Official Signature . Professional Engineer's Certification: Date I attest that this application for PINE CREEK SUBDIVISION PHASE 3 has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to I exceed $10,000 as well as civil penalties up to $25,000 per violation, 2a. JEFFREY A. BOONE, PE Professional Engineer Name 2b GREENBRIER DESIGN GROUP, PC Engineering Firm 2c. 2108 SOUTH BOULEVARD, SUITE 114 Mailing Address 2d, CHARLOTTE 2e. NC 2f. 28203 City State . Zip , 2g. 704-347-4972 :2h. 704-347-4973 2i. jboone@greenbrierriesign.com E-mail Telephone Facsimile • SEAL Seal, Signature &Date UT'A f1-1 1 (1,4 il) 0.4 0.8 l.2 1.6 2 mi Map center is UTM 17 528780E 3924725N (WGS84/NAD83) Kannapolis quadrangle Projection is UTM Zone 17 NAD83 Datum t )0 3 0� K�.. NAPO S August 29, 2 ' 06 NC Div of Environmental Management Department of Environment and Natural Resources-- Division of Water Quality 610 East Center Drive, Suite 301 Mooresville, North Carolina 28115 Re: Pine Creek Sewer Extension — Phase 5 City of Kannapo➢is - Cabarrus County Dear Sir or Madam: 06501-05 Please find attached for your reviewand approval the orig final and one copy of the permit application and a check for $400.00 for the processing fee for the above reference project. Also enclosed is the flow acceptance letter from the Water & Sewer Authority of Cabarrus County Mating they will accept and treat the additional wastewater at the Rocky River Regional Wastewater Treatment Plant. The Water and Sewer Authority of Cabarrus County Standard Specifications for Wastewater Collections Systems were approved by your office and are being maintained by the Division of Environmental Management. This project will be installed in accordance with these Standard Specifications. Please call me at 704-938-1519 if you have any rluesti Sincerely, Stephen Bissinger, PE Assistant City Engineer 06501-05 Pine Creek ph5 sewer permit letter.dac T act-, , D NATURAL RED:Ng:LLD RA AUG 3 1 200o 0 L 1 T 7 0-4 938,1,519 NC 28082-1 248 120 S. Hain St. 1- 704„938.6810 Permit Number WQ0030786 Central Files APS SVVP 09/14i06 Permit Tracking Slip Program Category Non -discharge Permit Type Fast Track Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer samanhou-gnazale Permitted Flow 5280 Facility Facility Name Pine Creek Subdivision Phase 5 Location Address Owner Owner Name City of Kannapolis Status Project Type In review New Project Version A Permit Classification Individual Permit Contact Affiliation Pates1vent9 Orig Issue App Received Draft Initiated 08/31/06 Regulated Activities Subdivision Wastewater collection Outlet! NULL Waterbody Name Scheduled issuance MajoriMinor Region Minor Mooresville County Canarrus Facility Contact Affiliation Owner Type Government - Municipal Owner Affiliation Melvin Rape, PE PO Box 1199 Kannapolis Public Notice Issue Reaueqq0/Recgived gv Additional information requested Additional information received NC 280811199 Effective Expiration Stream Index Number Current Class Subbasin PINE CREEK DEVELOPERS, LLC 5555 CONCORD PKWY S. STE 409 CONCORD, NC 28027-4622 PH.(704)-455-7034 PAY TO THE ORDER OF MEMO e00 1 300 1:0 5 0004961. 0006 5 Bank of Arne ACH RiT 053000196 6 0 6383 SACC WATER & SEWER AUTHORITY OF CABARRUS COUNTY Mr. Michael Legg City Manager City of Kannapolis PO Box 1199 Kannapolis, NC 28082-11.99 0 12 July 13. 2006 Subject: Flow Acceptance Pine Creek Sewer Extension — Phase 5 94( JUL 1,;1•,,i'1 1 232 Davidson Hwy, Co1ricord, 8.1C 28027 mad to: P,O,,.Licx.r 428 Concord, NC 23026-0428 Phone° 70.4,786.1783 Fax: 704.7195.1i564 Dear Mr. Legg: This is in response to the City's request for flow acceptance received 6/27/06. The Water and Sewer Authority of Cabarrus County (WSACC) has or currently expects to be able to make available capacity at the Rocky River Regional Wastewater Treatment Plant and appropriate sewer interceptors to transport and treat the wastewater from the proposed project.. WSACC agrees to accept wastewater from the proposed Pine Creek Subdivision (Phase 5), which will consist of 11 single family residential lots. This is based on the information provided by Greenbrier Design Group, P.C. (Engineer for the Project) using North Carolina Department of Environment and Natural Resources (NCDENR) wastewater flow guidelines. The projected flow is 5,280 gpd; however WSACC expects the actual wastewater flow to more closely approximate 3,960 gpd based upon Master Plan engineering data, By requesting .flow acceptance, the City of Kannapolis acknowledges that WSACC may need to upgrade, expand, or construct new facilities to accommodate the increased flow volume granted by this and previous flow acceptance. Appropriate design and construction will be initiated when actual flows dictate but may be subject to situations that WSACC does not expect or control. Based upon flow of 5,280 gpd and cost of $8.126/gpd to provide treatment and transportation capacity, this flow acceptance represents an estimated capital expenditure in excess of 842,905., For your information and based upon NCDENR wastewater flow guidelines, WSACC has approved 2,713,964 gallons of tlow acceptance for the City of Kannapolis from 1992 to present and 290,494 gallons of flow acceptance year-to-date including this request. Based upon the approved flow acceptances, WSACC has committed capacity valued in excess of $22,053,671 for the City of Kannapolis since '1992 including 82,360„554 for this calendar year. .Projects on the CIP are subject to approval by WSACC's Board of Directors, support from local governing bodies, regulatory approval, and funding 'availability. At this time there are no scheduled upgrades to WSACC facilities in the current six year Capital Improvement Program (CIP) that are located downstream of this proposed project. It should be noted that the list and ity f Kannapolis Pine Creep Sewer °er xtel sion w Phase ase tlq Page 2 of schedule of CIP projects are and needs, of tl f cc: Please note that if cans. approval, the approval is atiI\ SACC, in wr iti Tf you have any questions, vACC Engineering n Staff Moody, P.E./KannapolisCity l at: inter Me ItoniKannapo[r Boone, P. .1 Greenbrzer Design Group, P (' id are re deed pe nod call r to r+ n of this project is not started with n two ( tided and a second request and appro ai en construction of this project is initiate& please ca3 -ti 1783 , °order H. Rowell, P.E. Engineering Director nging co raditic ns years of the date will be required.