Loading...
HomeMy WebLinkAboutWQ0028897_Regional Office Historical File Pre 2018Michael F, Easley, Ciovernor William CI Ross Jr., Secretary North Carolina. Department of Environment and Natural Resources Alan W", Director. Division of Water Quality June 1, 2005 Mr Wilmer rVielton, Public Works Director City of Kannapolis Post Office Box 1199 Kannapolis, North Carolina 28081 Subject: Permit No, WQ0028897 City of Kannapolis F&M Bank Wastewater Collection System Extension Cabarrus County, North Carolina Dear Mr, Melton: In accordance with your application received on May 19, 2005, we are forwarding herewith Permit No. WQ0028897 dated June 1, 2005, to the City of Kannapolis for the construction and operation of the subject wastewater collection system ex(ension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H 0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application, It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules, Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board, One. NorthCarolina ,Mooresvil le Regional 0.. ce 610 East Center Ave„, Suite 301 Mooresville, INC 28.1.15 Phcine. (704) 663-.16.99 Fax (704 63.-,6040 Internet h2o,enrstate,nc,us Customer Service 1-8'77-623-6748 An Equal Opportunity/AI-fin-olive Action Employer —50% Recycled:10% Post Consumer Paper Mr. Wilmer Melton Page 2 June 1, 2005 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Kannapolis for the construction and operation of approximately 114.04 linear feet of 8-inch gravity sewer to serve 26 employees as part of the F&M Bank project, and the discharge of 650 gallons per day of collected domestic wastewater into the City of Kannapolisexisting sewerage system, pursuant to the application received May 19, 2005, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable, the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Water and Sewer Authority of Cabarrus County (WSACC) Rocky River WVVTP (NPDES No, NC0036269) prior to being discharged into the receiving stream, This permit shall become voidable unless the agreement between the City of Kannapolis and WSACC for collection and final treatment of wastewater is in full force and effect, If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Basinger at (704) 663-1699. Sincerely, ,for Alan VV, Klimek, P.E. cc: Cabarrus County Health Department Mooresville Regional Office, Surface Water Protection (WWTF Permit No. NC0036269) Jill Brim, Concord Engineering & Surveying, Inc, Surface Water Protection Central Files Marie Doklovic, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1, This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200: the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H ,0227, If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b, A map of the sewer system shall be developed and shall be actively maintained, c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time, f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B ,0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215,1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State, Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable, 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc,: or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice moil messages or faxed information is permissible, but shall not be considered as the initial verbal report, Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) -0 or (19) 733-3300. Persons reporting any of the above occurrences shall file a spill report hy completing Part i of Form S S (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part 11 of Form - (or the most current Division approved form) can also be completed to show that the SSO was beyond control. Permit issued this the 1 day of June, 2005. NORTH CAROLINA ENVIRONMENTALMANAGEMENT COM ISSION `ar Alan VV. Klimek, P,E., director Division of Water Quality By Authority of the Environment l Management Coc mis for Perini Number WQ0028897 Fast Track Engineering Certification Permit No WQ0028897 June 1, 2005 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile v ews of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be clearly identified on the record drawings or in written summary form, Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and ail required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division, ENGINEER'S CERTIFICATION Partial El Final as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe ([1] periodically. [I] weekly:. LJfull time) the construction of the F&M Bank, Cabarrus County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit: 15.A NCAC 2H .0200: the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable, the Division's Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials: North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Perrnittee to appropriate enforcement actions. CentraI Files P SWP 0El01 /0 Permit Number 00 Program Category Non -discharge Permit Type. Gravity Sewer Ext Extensions Primary Reviewer sonja,basinger' Permitted Flow 650 Facility Facility Narrte F&M Bank Location Address Owner Fast nsion, rat or Pump Star ons, Pressure Sewer Owner Name City of Kannapolis Date Permit Tracking lip Status in review Version Per rnt Contact Aff Project Type New Project Permit Classification Individual atien Major/ /nor Minor Region Mooresville County Cabarrus Facility Conte ct Affiliation Scheduled Orig Issue App Received Draft Initialed issuance 05019/05 Regulated Aptly Commercial ercial r industrial. rather U�Pastewater collection iutran Owner Type Government - Municipal Owner Affiliation Melvin Rape PE PO Box 1199 Innpolis NC Publi Notice Issue OS - Retinas ed/Received Events Additir nal information requested Add tidnai information received Effective `aterbady Marne stream Index Nu be 2808 199 Expired Current Class subbasin T-TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS USE THE TAB KEY TO MOVE FROM FIELD TO FIE Owner: City of Kannapolis D Full Legal Name (company, municipality, HOA, utility, etc.) z 1b. Wilmer Melton, Director of Public Works, City of Kannapolis Application Number: (to be completed by DWQ) L21LL' '. 0 Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authoriz The legal entity who will own this system is: ❑ Individual ❑ Federal Municipality ❑ State/County ❑ Private Partnership ❑ Corporation ❑ Othe PAGE 3 1 d. 1401 Bethpage Road 0 LL Z 1f. NC 0 z State Street Address 1 h. 704-920-4200 Telephone 2. Project (Facility) Info 2a. F&M Bank ation: Facsimile Brief Project Name (permit Contact Person: Jill M. Brim ill refer to thins name) Name and Affiliation of 3b. 704-786-5404 0 eone 1 e. Kannapolis City signing officials!) 1 g. 28081 Zip Code 1j. wmeltontci.kannapolis.nc.us E-mail 2b. Cabarrus County Where Project is Lo no Can Answer Questions About this Application Phone Number Project is E New ❑ Modification (of an existing permit) specify): 3c, jillbrim@concordengineering.com E-mail If Modification, Permit No,: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.), Only include the modified information in this permit application - do net duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is Public (skip to Item 8(3)) ❑ Private (go to Item 2(a)) 2a. If private, applicant will be: 2b, If sold, facilities owned by a (must choose one ❑ Retaining Ownership (i,e. store, church, single office, etc.) or Leasing units (lots, townhomes, etc. - skip to Item 8(3)) 0 Selling units (lots, townhomes, etc, - go to Item B(2b)) Water & Sewer Authority of Cabarrus Count _(WSACC) Owner of Wastewater Treatment Facility (WWTF) Treating 4a, Rocky River Wastewater Treatment Plant Name of WWTF City of C.enct1Cf Owner of Downstream Sew The origin of this wastewater is (check al 0 Residential Subdivision 0 Apartments/Condominiums ❑ Mobile Home Park ❑ School ❑ Restaurant Office Public Utility (Instruction III) 0 Homeowner Assoc./Developer (Instruction IV) astewater From This Project alb, NCO03Ff29' WWTF Permit No. Not Known m. Receiving Sewer Size Ej Car Washes El Institution 0 Hospital ❑ Church ❑ Nursing Home ❑ Other (specify): Permit Number of Downstream Sewer (if known Volume of wastewater to be permitted in this project: 650 gallons per day If the permitted flow is zero, indicate why: ❑ Interceptor Line - Flow will be permitted is subsequent pe El Flow has already been allocated in Permit No, 0 Rehabilitation or replacement of existing sewer with no new flow expected 100 °/© Domestic/Commercial % Industrial % Other (specify): that connect to this line FTA 02/03 - Rev. 2 04/04 T-TRACK .APPLIC ATION for GRAVITY SEVERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 z 0 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(1)(3). F&M Bank - 25 gaVempioyee - 26 employess * 25 galemployee = 650 gpd 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8' ENTER TOTAL LINE LENGTH IN MILES Length (feet) 114.04 0 Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID (self chosen - as shown on Design Flo plans for cross-reference) (MGD) Operational Point GPM @ TDH Gravity or Force Main (use the pull down menu) Gravity Power Reliability Option (1- dual line feed; 2- permanent generator w/ATS; 3- portable generator w/telemetry; 4-wet well storage) 12a Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No N/A Yes ❑ No ❑ N/A ❑ Yes ❑ No N/A Sedimentation and Erosion Control Plan? Stormwater? FTA 02/03 - Rev. 2 04/04 . . ST-TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 0 0 1, Use the Division's guidance document entitled, DETERMMNG STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on Name of Waterbody Stream Waterbody map for cross-reference) Waterbody County River Basin Index Classification Submit the 8.5" x 11 COLOR topographic map as required in instruction VI regardless of whether a classification is provided! 1. Applicant's Certification: 1 a. Signing Official Signature 2. Professional Engineer's Certification: 1, Wilmer Melton, attest that this application for F&M Bank has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215,68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25 000 per violation. Date I attest that this application for F&M Bank has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.65, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Jill M. Brim Professional Engineer Name 2b, Concord Engineering & Surveying, Inc. Engineering Firm 2c. PO Box 268 Address 2d, Concord City 2e, NC 2f, 28026-0268 State Zip 2g. 704-786-5404 2h. 704-786-7454 2i. Jillbrim c ncorden ineerin .com Telephone Facsimile E-mail Seal, Signature & Date 17A 02/03 - Rev, 2 04/04 0.6 0.9 1.2 1.5 km 2 0.4 0.6 0.8 Map center is UTM 17 536201E 3923503N (WGS84/NAD83) Concord quadrangle Projection is UTM Zone 17 NAD83 Datum op 7&n=3923503.00009 4 e=536201&s=50&size=l&laver-[ i ,.. 31 r' 004 KANNAPOL IS May 17, 2005 NC Div of Environm.ental 'Management Department of Environment and Natural Resources -- Division of Wate. 610 East Center Drive, Suite 301 Mooresville, North Carolina 28115 Re: F&M Bank Sewer Extension City of Kzumapolis - Cabarrus County Dear Sir or 'Madam: ua.lit 0350 1-88 Please find attached for your review and approval the original and one copy of the permit application and a check for $400..00 for the processing fee for the above reference project. Also enclosed is the flow acceptance letter from the Water & Sewer Authority ofCabarrus County stating they will accept and treat the additional wastewater at the Rocky River Regional Wastewater Treatment Plant. The Water and Sewer .Authority of Cabarrus County Standard Specifications for Wastewater Collections Systems were approved by your office on August 1.1, 1993 and are being maintained by the Division of Environmental Management, New Water & Sewer Authority ofCabarrus County Standard Specifications were submitted January 2001, for review and approval. This project will be installed in accordance with these Standard Specifications. Please call me at 704-938-1519 if you have any questions. Sincerely, DEPT Or ENVIRONMENt, 14„.P.E., Et Stephen J. iss1nger, PE Assistant City Engineer pm 9 20T1 03501-88 FM bank sewer permit letter.doc CIT Y 0 F K A N N A P 0 L Engineering Department T '704'938.1519 E 704.938,6810 P.O. Box 1248 Kannapolis. NC 28082-1-248 120 S. Main St. Kannapais, NC 28081 WATER & SEWER AUTHORITY OF CABARRUS COUNTY May 12, 2005 Mr. Michael Legg City Manager City of Kannapolis PO Box 1199 Kannapolis, NC 28082-1199 Subject: Flow Acceptance F&M Bank OfficeT 132 Davidson Hwy, Concord, NC 28027 P,O. Box 428 Concord, NC 28026,0428 Phone: 7 04.786.178,3 Fax: .704,..795:1 564 Dear Mr, Le,: This is in response to the City's request for flow acceptance received 4/26/05. The Water and Sewer Authority of Cabarrus County (WSACC) has or currently expects to be able to make available capacity at the Rocky River Regional Wastewater Treatment Plant and appropriate sewer interceptors to transport and treat the wastewater from the proposed project. WSACC agrees to accept wastewater for the proposed commercial connection. This is based on the information provided by Concord Engineering & Surveying, Inc. (Engineer for the Project) using North Carolina Department of Environment and Natural Resources (NCDENR) wastewater flow guidelines. The projected flow is 650 gpd; however WSACC expects the actual wastewater flow to more closely approximate 553 gpd based upon Master Plan engineering data, By requesting flow acceptance, the City of Kannapolis acknowledges that WSACC may need to upgrade, expand, or construct new facilities to accommodate the increased flow volume granted by this and previous flow acceptance. Appropriate design and construction will be initiated when actual flows dictate but may be subject to situations that WSACC does not expect or control. Based upon flow of 650 gpd and cost of $8.126/g,pd to provide treatment and transportation capacity, this flow acceptance represents an estimated capital expenditure in excess of $5,281. For your information and based upon NCDENR wastewater flow guidelines, WSACC has approved 2,221,809 gallons of flow acceptance for the City of Kannapolis from 1992 to present and 43,010 gallons of flow acceptance year-to-date including this request. Based upon the approved flow acceptances, WSACC has committed capacity valued in excess of $18,054,419 for the City of Kannapolis since 1992 including 5349,499 for this calendar year. Projects on the CIP are subject to approval by WSACC's Board of Directors, support from local governing bodies, regulatory approval, and funding availability, At this time there are no scheduled upgrades to WSACC facilities in the current six year Capital Improvement Program (CIP) that are located downstream of this proposed project. It should be noted that the list and schedule of CIP projects are tentative and are revised periodically to reflect changing conditions and needs. City of Kannapolis F&M Bank May 12, 200 Page 2 of Please note that if construction of this project is not started Within two (2 years of the date of this approval, the approval is rescinded and a second request and approval will be required. Please notify WSACC, in writing, when construction of this project is initiated. If you have y questions, please call e at '70 -'7 - l . Sincer Davis, RE. Engineering Director cc: WSACC nginee ° Staff Jeff Moody, P.E./Kannapolis City Enginez Wilmer MeltoniKannapolis Jill Brim, E