Loading...
HomeMy WebLinkAboutWQ0024868_Regional Office Historical File Pre 2018North Carol' February 16, 2005 The Honorable Troy Barnhardt, Mayor Town of Mount Pleasant Post Office Box 787 Mount Pleasant, North Carolina 28124 Michael F. EaNtey. cioventor Witham Ci. Ross Jr- Secretary flUTlT11(1l of rwironincnt wid Natural R.csotiree,s Alan W. Klimek, P.E, Director Division of W'racr Quality Subject: Permit No. WQ0024868 Town of Mount Pleasant North Drive/ Jackson Street Force Main Wastewater Collection System Extension Cabarrus County, North Carolina Dear Mayor Barnhardt; In accordance with your application received on February 7, 2005, we are forwarding herewith Permit No, WQ0024868 dated February 16, 2005, to the Town of Mount Pleasant for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein, This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permiftee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215,6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board, Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC .28115 Internet: h2o.enr.state.no,us Customer Service: 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer - 50% Retyciedt10% Post Consumer Paper Phone, (704)665-109 Fax (704"I 663-6040 orthCatolina ,Naturally Mayor Troy Barnhardt Page 2 February 16, 2005 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Town of Mount Pleasant for the construction and operation of approximately 375 linear feet of 2-inch force main to serve 3 single family residences as part of the North Drive/ Jackson Street Force Main project, and the discharge of 1,080 gallons per day of collected domestic wastewater into the Town of Mount Pleasant's existing sewerage system, pursuant to the application received February 7, 2005, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast - Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the Water and Sewer Authority of Cabarrus County (WSACC) Rocky River WVVTP (NPDES No. NC0036269) prior to being discharged into the receiving stream, This permit shall become voidable unless the agreement between the Town of Mount Pleasant and WSACC for collection and final treatment of wastewater is in full force and effect. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Basinger at (704) 663-1699. cc: Cabarrus County Health Department Mooresville Regional Office, Water Quality Section Mark Lambert, Frazier Engineering Water Quality Central Files Marie Doklovic, PERCS Sincerely, f for Alan W. Klimek, P.E. F Permit No. NC0036269) NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: , This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times, The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227, If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H *0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L 0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. cl. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e* 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week, e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years, h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6, Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part II of Form CS-SSO (or the most current Division approved fomi) can also be completed to show that the SSO was beyond control. Permit ssued this the 16th day of February, 2005. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Alan W. Klimek,43.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0024868 Fast Track EnaneerinQ Cer Permit No. WQ0024868 February 16, 2005 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permitregulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division, Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division, ENGINEER'S CERTIFICATION ri Partial [1] Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe ([1] periodically, weekly, full time) the construction of the North Drive/ Jackson Street Force Main, Cabarrus County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE SURFACE WATER PROTECTION 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 ATTN: DEE BROWDER The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. FAST -TRACK APPLICATION for GRAVITY SEWERS PUi4P STATIONS, AND FORCE MAINS PAGE 3 LL USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Owner: 1 a. Town of Mount Pleasant Applieatian Numt (to be completed by DWQ) Full Legal Name (company, municipatity, HOA, utility, etc.) z 1b. Troy W. Barnhardt, Mayor 0 z 0 Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) lc, The legal entity who will own this system is: Individual 0 Federal Municipality ❑ State/County ❑ Private Partnership 0 Corporation ❑ Other (specify): 1 d. PO Box 787 Street Address NC State Mount Pleasant City 1 g. 28124 1 h. 704-436-9803 li. 704-436-2921 lj. Telephone Facsimile 2. Project (Facility) Information: 2a, North Drive/Jackson Street. Force Main Brief Project Name (permit will refer to this name) 3. Contact Person: 3a. Mark. Lambert,, Frazier En ineerin , P.A Name and Affhiation of Someone Who Can Answer Questions About this Application Zip Code E-mail 2b. Cabarrus County Where Project is Located 3b. 704-822-8444 Phone Number ....... ..._ ...... .... 1. Project is ® New ❑ Modification of an existing permit) if Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (Le. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is # Public (skip to Item B(3)) 2a, If private, applicantwitibe: 3c. mlambert c@frazier-engineerin .co E-mail go to item 2(a)) 2b, If sold, facilities owned by a ❑ Retaining Ownership (i,e, store, church, single office, etc.) or 0 Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) 3. _Water and Sewer AuthoritCabarrus Coun Owner of Wastewater Treatment Facility (WWTF) Treating Wa Q 4a. Rocky River Regional Wastewater Treatment Plant Name of WWTF Z 5a, Town of Mount Pleasant '5b. 8 inches Owner of Downstream Sewer Receiving Sewer Size 6. The origin of this wastewater is (check all that apply): ❑ Residential Subdivision ❑ Apartments/Condominiums 0 Mobile Horne Park School 0 Restaurant 0 Office 0 Public Utility (Instruction iII) 0 Homeowner Assoc./Developer (Instruction IV) ewater From This Project 4b. NC0036269 WWTF Permit No. c. Unknown Permit Number of Downstream Sewer (if known 0 Car Wash ❑ Institution 0 Hospital El Church Nursing Home Other (specify): Individual Homes 7. Volume of wastewater to be permitted in this project; 1,.080 gallons per day 100 % Domestic/Commercial % Industrial Other (specify): 8. If the permitted flow is zero, indicate why:. 0 Interceptor Line - Flow will be permitted is subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected FTA 02/0 - Rev. 2 04/04 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 0 0 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(I) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(I)(3). Three three -bedroom homes at 360 gallons per home per day = 1,080 gallons per day 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 2 375 ENTER TOTAL LINE LENGTH IN MILES 0.07 11, Summary of Pump Stations fo be Permitted (attach additional sheets as necessary) Gravity or Force Main (use the pull down menu) Force Main Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator w/ATS; 3- plans for cross-reference) (MGD) GPM @ TDH portable generator w/telemetry; 4-wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force, Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable?! Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No N/A Sedimentation and Erosion Control Plan? 0 Yes ❑ No N/A Stormwater? ❑ Yes 0 No N/A FTA 02/03 - Rev. 2 04/04 AS'I;-TRACK AFPEICATION for GRAVITY" SE°rERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets a necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: 07 Z 0 A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map (self chosen - as shown on map for cross-reference) Waterbody Stream Waterbody Waterbody County River Basin Index Classification Name of Submit the 8.5" x 11°' COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! Applicants Certification: 1, Troy W. Barnhardt, attest that this application for North Drive/Jackson Street Force Main has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143- 215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Sign' Official rgnature 2. Professional Engineer's Certification: Date I attest that this application for North Drive/Jackson Street Force Main has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentations to the best of my knowledge. 'further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. Mark Lambert Professional Engineer Name 2b. Frazier Engineering Engineering Firm 2c. 8261 Highway73, Suite C Address 2d. Stanley City 2g. 704-822-8444 2h. 704-822-8666 Telephone Facsimile 2e, NC 2f. 28164 State Zip 2i. mlambert@frazier- engineering.com FTA 02/03 - Rev. 2 04/O4 SCALE 1:. WATER & SEWER AUTHORITY OF CABARRUS COUNTY January 31, 2005 Troy W. Barnhardt Mayor Town of Mt. Pleasant P. O. Box '787 Mt. Pleasant, NC 28124 Subject: Flow Acceptance North Dr./Jackson St. Sewer Extension Office: 232 Da Odon Hwy. !: Concord, NC 26[127 Ma to; R(), Box 426 Concord, NC 2B026-0428 Phone: 7:04.766,1 783 FaX: 704.795.1564 Dear Mayor Barnhardt: This is in response to .the TOW11 S request for flow acceptance received 1/25/05. The Water and Sewer Authority of Cabarrus County (WSACC) has or currently expects to be able to make available capacity at the Rocky River Regional Wastewater Treatment Plant and appropriate sewer interceptors to transport and treat the domestic wastewater from the proposed sewer line extension, WSACC agrees to accept wastewater from the proposed three (3) neW connections based on information provided by Frazier Engineering, P.A. (Civil Engineer for the project) using North Carolina Department of Environment and Natural Resources (NCDENR) wastewater flow guidelines. The projected flow is 1,080 gpd; 'however WSACC expects the actual wastewater flow to more closely approximate 750 gpd based upon Master Plan engineering data. By requesting flow acceptance, the Town of Mount Pleasant acknowledges that WSACC may need to upgrade, expand, or construct new facilities to accommodate the increased flow volume granted by this and previous flow acceptance. Appropriate design and construction will be initiated when actual flows dictate but may be subject to situations that WSACC does not expect or control, Based upon flow of 1,080 gpd and cost of $8.126/gpd to provide treatment and transportation capacity, this flow acceptance represents an estimated capital expenditure in excess of 58,776. For your informationand based upon NCDENR wastewaterflow guidelines, 'WSACC has approved 71,890 gallons of flow acceptance for the lawn ofMount Pleasant from .1992 to present and 1,080 gallons of flow acceptance year-to-date including this request. Based upon the approved. flow acceptances, WSACC has committed capacity valued in excess of $584,178 for the Town of Mount Pleasant since '1992 including $8,776 for this calendar year. Downstream facilities from the proposed project are scheduled in WSACC's current Capital Improvement Program (CIP) to increase available capacity. Projects on the CIP are subject to approval by: WSACC's Board of Directors, support from local governing bodies, regulatory approval, and funding availability. The followirw, schedule of CIP projects is tentative and may be delayed by unforeseen circumstances: • Upgrade of the WSACC Mount Pleasant- a pump stations and force main, Scheduled completion date: 2006. "fowl of Mount Pleasant North Dr./Jackson St. SewerExtension January 31, 2005 -Page 2- If con s(ruction of this protect is not started within two (2) years of the date of this approval, the approval is rescinded and a second request and approval will be required Please notify WSACC, in writing, when construction of this project is initiated, lfyou have any questions, please call me at (704) 786-1783. JCM:EfiRtiss cc: WSACC Engineering Staff Sincerely. clt. 1 xecutiv,°e Director Mark Larabert/Fraizer Engineering Permit Number WQ0024868 Program Category Non -discharge Fast Track Permit TN/Pe Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer sonja,basinger Permitted Flow 1080 Facility Facility Name North rive/ Jackson Street Force Main Location Address Owner Central Files: APS SWP 02/10105 Permit Tracking Slip Status Proiect Type In review New Project Version Permit Classification Individual Permit Contact Affiliation Mainr/Minor Minor Region Mooresville County Cabarros Facility Contact Affiliation Owner Name Town of Mount Pleasant Dates/Events Odd issue App Received 02/07/05 Regulated Activities Draft Initiated Sundivision Wastewater collect on Outten NULL Owner Type Government - !Municipal Owner Affiliation Troy Barnhardt, Mayor PO Box 787 Mount Pleasant NC 28124 Scheduled Issuance Public Notice Issue Effective Expiration Alf /06— Requested/Received Events Additional information requested Additional information received Waterbodv Name Stream Index Number Current Class Subbasin TO P WATER�+µ, 4 _ y fiy �ypry f q..A M'' ff J' MOUNT P Four uxdred North Carolr Environinent an tura Resources 919 North Main greet THIS DISBURSE APPROVED A (oI11 LOO G