Loading...
HomeMy WebLinkAboutWQ0024825_Regional Office Historical File Pre 2018Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Rmourtes Alan W. Klimek, P.E. Director Division of Water Quality February 1, 2005 Mr. Wilmer Melton, Public Works Director City of Kannapolis Post Office Box 1199 Kannapolis, North Carolina 28081 Subject: Permit No. WQ0024825 City of Kannapolis Winecoff Commons Sewer Extension Wastewater Collection System Extension Cabarrus County, North Carolina Dear Mr, Melton: In accordance with your application received on January 27, 2005, we are forwarding herewith Permit No, WQ0024825 dated February 1, 2005, to the City of Kannapolis for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1) 15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Perrnitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 610 East Center Ave_, Suite 301 Mooresville, Internet: h2o.enr.stale.nc.us Customer Service; 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper NC28115 Phone: (7( 663-1699 Fax; 7 Mr. Wilmer Melton Page 2 February 1, 2005 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Kannapolis for the construction and operation of approximately 370 linear feet of 8-inch gravity sewer to serve as an interceptor line as part of the Winecoff Commons Sewer Extension project, with no additional discharge of collected domestic wastewater (flow will be permitted in subsequent permits that connect to this line) into the City of Kannapolis' existing sewerage system, pursuant to the application received January 27, 2005, and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Perrnitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit, The sewage and wastewater collected by this system shall be treated in the Water and Sewer Authority of Cabarrus County (WSACC) Rocky River WWTP (NPDES No. NC0036269) prior to being discharged into the receiving stream. This permit shall become voidable unless the agreement between the City of Kannapolis and WSACC for collection and final treatment of wastewater is in full force and effect. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Sonja Basinger at (704) 663-1699. Sincerely, /2-6- f•oi• Alan W. Klimek, P.E. cc: Cabarrus County Health Department Mooresville Regional Office, Water Quality Section (WVVTF Perrnit No. NC0036269) Stephen Bissinger, Alley, Williams, Carmen & King, Inc. Water Quality Central Files Marie Doklovic, PERCS NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein, 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times, The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed and shall be actively maintained. c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. general observation af the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State: 6. Per 15A NCAC 2H .0220, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for he life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification; The Permittee shall verbally report to a Division of Water Quality employee at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Voice mail messages or faxed information is permissible, but shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Forrn CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Part of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond contra Permit issued this the 1st day of February, 2005. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION cc--) for Alan W. Klimek,,P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0024825 Fast Track Engineering Certification Permit No. WQ0024525 February 1, 2005 Complete and submit this form to the permit issuing regional office with the following: One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division, Therefore, it is highly recommended that this certification be sent in a mariner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION Partial Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (D periodically, El weekly, full time) the construction of the Winecoff Commons Sewer Extension, Cabarrus County project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: „.' SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE NC 28115 ATTN: DEE BROWDER The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. Central Files: SWP 01 /31 /05 PPS it Number Wt 0024825 Permit Tracking Slip Program Category Non -discharge Permit Type Fast Track Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer sonja.basinger Permitted Flow 0 Facility Status Project Type in review New Project Version Permit Classification Individual Permit Contact Affiliation Facility Name Winecoff Commons Sewer Extension Location Address Owner Owner Name City of Kannapolis dates/Events Scheduled Orig Issue App Received Draft Initiated Issuance 01/27/05 Regulated Activities Commercial or industrial, other Wastewater collection Outfail NULL Major/Minor Region Minor Mooresville County Cabarrus Facility Contact Affiliation Owner Type Government - Municipal Owner Affiliation Melvin Rape, PE NC 280811199 PO Box 1199 Kannapolis Public Notice Issue 2J /03 Requested/Received Events Effective Additional inforrnation received Additional information requested Expiration Waterbody Name Stream Index. Number Current Class Subbasin alley, williams, carmen ,$ i1► , Inc. ENGINEERS „,& ARCHITECTS p.c. box 1179 / 740 chapel hill rod Merlin®tans north caroling 27216 telephone 336/226-5534 ;fly Four hundred and xx /100 Dollars PAY TO THE ORDER OF II'O1?369» I:053101i2LI: 51&LEA2'129 I' aims, January 25, 2005 NC Div of Environmental Management Department of Environment and Natural Resources Division of Water Quality 610 East Center Drive, Suite 301 Mooresville, North Carolina 28115 Re: City of K.annapolis Winecoff Commons Sewer Extension Dear Sir or Madam: 05503 Please find attached for review and approval the original and one copy of the permit application, and the processing fee of $400.00. The Water & Sewer Authority of Cabarrus County Standard Specifications for Wastewater Collections Systems were approved by your office on August 11, 1993 and are being maintained by the Division of Environmental Management New Water & Sewer Authority of Cabarrus County Standard Specifications were submitted December 1995, for review and approval. This project will be installed in accordance with the Water & Sewer Authority of Cabarrus County Standard Specifications. This project consists of the installation of approximately 370 LF of 8-inch Gravity 'Flow Sewer Pipe. No additional sewer flow: will be added to the system with this extension; new flow will be permitted with a future extension. The system will be operated and maintained by the City. of Kannapolis. Please call me at 704-938-1515 if you have any questions. Sincerely, ALLEY, WILLIAMS, CARMEN & KING, INC. Stephen J. Bissinger, PE (5.503 sewer perr . eitcr,doc 120 South Mnin k P.O. Box eht)e; Kh.h ht)uttyhh. North Ctarchotti 28082 "Th,tt. (704.) 938- I 51h Fa„Y t 104) 938-68 • aohitk„).)tttitn i):11hglit 1.4 1960 CK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS .1.1•11•11.•000.1111, USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ) VV5,002 40 1. Owner: la. Jyof Kannapolis FullFu Legal Name (company, municipality, HOA, utility, etc.) PAGE 3 lb, Wilmer Melton, Director Public Works Q Signing Official Name and Title (Please review 15A NCAC 2H . 206(b) for authorized signing officials!) 0. 0 z 1— Telephone Facsimile 2. Project (Facility) Information: 2a. WINECOFF COMMONS SEWER EXTENSION Brief Project Name (permit will refer to this name) 3. Contact Person: lc. The legal entity who will own this system is: Individual Ej Federal E Municipality 0 State/County 0 Pr vate Partnership Ej Corporation 0 Other (sp ld. 1401 Bethpage Road Street Address if, NC State 1 e. Kannapolis City 28081 Zip Code 1h, 704-920-4200 1 i. 704-920-4244 1j, wmelton ',kann . LJ S E-mail 2b. ROS •ounty Where Project is Located • 3a Stephen J. Bissinger, Project Engineer Name and Affiiiation of Someone Who Can Answer Questions About this Application • 3b. 704-938-1515 3c. sbissirger@awck.com , ! Phone Number E-mail 1. Project is N New E Modification (of an existing permit) If Modification, Permit No.. For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is tEl Public (skip to item B(3)) 0 Private (go to Item 2(a)) 2a, if private, applicant will be: 2b. If sold, facilities owned by a (must choose one) Ej Retaining Ownership (Le. store, church, single office, etc.) or Leasing units (lots, townhomes, etc, - skip to Item B(3)) 0 Selling units (lots, townhomes, etc. - go to Item 8(2b)) 0 Public Utility (Instruction ID) 0 Homeowner Assoc./Developer (Instruction IV) 3. Water and Sewer Authority of Cabarrus County Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a, Rocky River Regional Waste Water Treatment Plant 4b. NC0036269 Name of WWTF WWTF Permit No. 5a, City of Kannapolis 5b, 8" `5c. Owner of Downstream Sewer Receiving Sewer Size Permit Number of Downstream Sewer (if known) 6, The origin of this wastewater is (check all that apply). 0 Residential Subdivision 0 Apartments/Condominiums 11 Mobile Home Park Ej School E:1 Restaurant 0 Office 0 Car Wash El Institution El Hospital 0 Church 0 Nursing Home Other (specify): Commercial 7. Volume of wastewater to be permitted in this project 0 gallons per day ^ y N 100 °A Domestic/Commercial If the permitted flow is zero, indicate why: - Flow will be permitted is subsequent permits that connect to this line 0 Flow has already been allocated in Permit No. 0 Rehabilitation or replacement of existing sewer with no new flow expected % Industrial % Other (specify): FTA 02/03 - Rev! 1 06103 CK APPLICATION for GRAVITY SEWERS,'Pl : P STATIONS, I) FORCE MANS 9, Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCA; .0219(I) for Item E(7) or the design flow for line or pump station sizing if zero flow in the space below. Values that in 15A NCAC 2H .0219(I)(1-2) must be approved prior to submittal of this application. Submit a separate the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699- accordance with 15A NCAC 2H ,0219(l)(3). No new flow. 10, Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) 8" ENTER TOTAL LINE LENGTH IN ES 370 0,07 miles Gravity or Force use the pull down rn Gravity Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator wf# 0 plans for cross-reference) (MGD) _ GPM © TDH portable generator wltellemetry; 4-wet well st LL z NIA. 12, Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations ar Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H ,0200 as app ® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate w) variance is requested: See Attachment SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLt t3. Have the following permitscertifications been suubmitttee. d for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No NIA Sedimentation and Erosion Control Plan? ❑ Yes ❑ No N/A Stormwater? ❑ Yes ❑ No NIA FTA 02/03 - e Location ID on Map (self chosen - as shown on map for cross-reference) 0 CK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE ,5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 I (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary), This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: E A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, E A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability ; option for any pump station near a Class C down slope waterbody. Name of Waterbody Stream Waterbody Waterbody County River Basin Index Classification Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! 1, Applicants Certification: la, 1, Wilmer Melton, 111, Dir. Public Works, attest that this application for Winecoff Commons Sewer Extension has been reviewed by me and is accurate and complete to the best of my knowledge 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signi g Official Signature Professional Engineer's Certification; Date 1 attest that this application for Winecoff Commons Sewer Extension has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design, Note: In accordance with NC General Statutes 143-215,6A and 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a, Stephen J. Bissinger Professional Engineer Name 2t) Alley, Williams, Carmen & King, Inc, Engineering Firm 2c, 120 S. Main Street, PO Box 1248 Address 2d, Kannapolis _2e. NC 2f, 28082 City State Zip 2g. 704-938-1515 2h. 704-938-6810 21. sbissinger@awck,com Telephone Facsimile E-mail z,„„3, - frk a „ „: aa( Sea( Signature & pate_ FTA 02/03 - Rer 1 06/03 gtM,