Loading...
HomeMy WebLinkAboutWQ0022746_Regional Office Historical File Pre 2018Michael F. Easley, Governor William, G. Ross:Jr, Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, RE„ Director Division of Water Quality Coieen H. Sullins, RE., Deputy Director Division of Water Quality June 24, 2003 Mr. Paul Campbett, Director of Engineering City of Concord P.O. Box 308 Concord, North Carolina 28026-0308 SubjectPermit No. WQ0022746 City of Concord Business Blvd Sanitary Sewer Wastewater Collection System Extension Cabarrus County Dear Mr. Campbell: In accordance with your application received on May 27, 2003, we are forwarding herewith Permit No. WQ0022746, dated June 24, 2003, to the City of Concord for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to Permit Condition 3 which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system -wide collection system permit issued to the Permittee. Also note Permit Condition 12 regarding unknown development. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 1)15A NCAC 2H .0200; 2) the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; 3) and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adapted June 1, 2000, as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. Mooresville Regional Office 919 N. Main Street, Mooresville, NC 28115 Internet http,//h2o enrstatemc us/ Telephone (704) 663-1699 Fax (704) 6 -6040 Airti NCDENR DENR Customer Service Center Telephone 1 800 623-6748 ^^, Mr, Paul Campbell Page 2 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Concord for the construction and operation of approximately 2,210 linear feet of 8-inch gravity sewer to serve an industrial park as part of the Business Blvd Sanitary Sewer project, and the discharge of 42,000 gallons per day of collected domestic wastewater into the Water & Sewer Authority of Cabarrus County's (VVSACC) Rocky River WWTP (NPDES No. NC0936269) existing sewerage system, pursuant to the application received May 27, 2003 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall become voidable unless the agreement between the City of Concord and WSACC for the collection and final treatthent of wastewater is in full force and effect. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, p 663-1699. Sincerely, ntaot Dee Browder at (704) for Alan W. Klimek, P.E. cc: Cabarrus County Health Department Mooresville Regional Office, Water Quality Section (WVVTF Permit No. NC0036269) Wanda Fuller, Concord Engineering & Surveying Water Quality Central Files NDPU Files NORTH CAROUNA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: f. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996, as applicable; the Division's Minimum Design Criteria 'for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000, as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. tf an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and any contravention of the groundwater standards in 15A NCAC 21,_ .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained, c. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (i.e. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High -priority sewer lines shall be inspected at least once per every six-month period of time. f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina -licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. it- this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved Under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings," and one copy of the supporting design calculations to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. Failure to abide by the conditions and limitations contained in this pemiit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes §143- 215.6A through §143-215.6C. 4 9 In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 28 .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 2H .0500. 11. Noncompliance Notification: The Permittee shall report by telephone to the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible, but in no case more than 24 hours or on the next working day, fallowing the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. 12. Unknown Development: No flow in excess of the quantity permitted herein, 42,000 GPD, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division of water Quality. Permit issued this the 24th day of June, 2003. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT CO for Alan W. Klim+(, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0022746 s ON 06124/03 t Number �"4 i M 22746 Permit Tracking Slip Program Category Non -discharge Permit Type `.3$L ' ra;;k Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dee.browder Permitted Flow 42000 Facility Facility Name Business Blvd Sanitary Sewer Location Address Owner Status Project Type in review New Project Version Permit Classification Individual Permit Contact Affiliation MaJor/M iinor Region Minor Mooresville County Cabarrus Facility Contact Affiliation Owner Name Owner Type City of Concord Government - Municipal Elates/Events Owner Affiliation Paul Campbell PO Box 308 Concord NC 28026 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective 05/27/03 Regulated Activities Requested/Received Events Commercial or industrial, other Additional information requested Additional information received Outfail NULL Stream Index Number Current Class Subbasin CONCORD ENGINEERING AND 06-78 SURVEYING INC. PH 704-766-5404 & PH 332-9934 P 0 BOX 268 CONCORD, NC 28026 PAY TO THE ORDER OF c' c Z 00 23 21, 7e 1:053 0073 0 L800 27? DATE DOLLARS 23247 66-73/531 BRANCH 13 Subject Business Park Date: Fri, 0 May 2003 15:51:48 From: "Marie o lovi " <rnarie.doklovic@riernail.net flow: Division of Water Quality lity To: "snnja c i lia " stnnj .Illarns@NCMaiLNet> Special conditi sn 12 for unkno+ n development No flow in excess of the quantity per Litt' he ein GPO, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division of Water Quaitt. K. Marie Doklavi , P Environmental Engineer Non -Discharge e itt n Division of Water Quality Do .lovic rriarie dok1ovie(i n rna J do ironm nt Division of Water Qua N.C. Department of Environment and. Natural Resources Division of Water Quality. Mooresville Regional. Office Non -Discharge Permitting 1. rrit 919 North Main Street Mooresville, North Carolina 28115 SUBJECT SANITARY SEWER EXTENSIONS BUSINESS BLVD SEWER EXTENSION City of Concord Cabarrus County Dear Sir or Madam: MA°a MC DEIPI NATURAL RES SVILLE REGIONAL OFFKE We are enclosing for your review and approval, one original. and one copy of the executed Non - Discharge Permit Application then, a check in the amount of $ 400.00, a letter of flow acceptance from the \VWTI and the Delegated Municipality Certification form for the installation of 2,210 +/- linear feet of 8-inch gravity sanitary sewer to serve the above mentioned project in the northwest section of Cabarrus County off Business BIv=d.. This application is in accordance with your Gravity Sewer Minimum Design Criteria. Upon completion of the project, you shall receive a copy of the Engineer's Certification and a copy of the Record Drawings. Your cooperation in this :matter is greatly appreciated. If there are any questions concerning this application or plans, please call us at (704) 920-5425 Sincerely, CONCC)RC) PD. Campbell, P.E. Dr. ector of Engineering DC/awd Enclosures cc: Proj c-t No.: 2003-O 19 Mile No. 2 (DWQ) z .ACK APPLICATION for GRA%SIT SIB ERS, PUMP STATIONS, AND FORC USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DM)) Owner: 1a„ The City of Concord Full Legal Name (company, municipality, HOA, utility, etc.) 1b, Paul Cam bellzC igning Official Name and Title (Please review 16A NCAC 2H .0206(b) for authorized signing officialsl) lc, The legal en who who will own this system is: Individual Federal ❑ Municipality State/County ❑ Private Partnership ❑ Corporation ❑ O1he 1 d. PO Box 308 1 e, Concord et. Address City 1 t. NC State lh. 704-920-5402 1'i. 10k( 79rhe 45 Telephone Facsimile 2. Project (Facility) Information: 2a. Business Blvd Sanitary Sewer Brief Project Name (permit will refer to this name Contact Person: 1 g. 28026 0308 Zip Code "Y E-mail beC c cia,1 uyz. 2b. Cabarrus pgcrfy): County Where Project is Located 3a, Wand Fuller, PE Project Engineer; Concord Engineering and Surveying Inc. Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 704-786-5404 c. wandafulier@concordengineering,com Phone Number E-mail 2. wner i New ❑ Modification (of an existing permit) If Modification, Permit No,: Public (skip to (tern B(3)) ❑ Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one • Retaining Ownership (i.e„ store, church, single office, etc.) Ej Leasing units (lots, townhomes, etc, - skip to Item B(3)) ❑ Selling units (lots, townhomes, etc, - go to Item B(2b)) Water and Sewer Authority of Cabarrus County 0 Public Utility (Instruction III) ❑ Homeowner Assoc./Developer (Instruction IV) Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project `4a. Rocky River WWTF '4b. NCBQ3621 U9 Name of WWTF WWTF Permit No. The City of Concord 5b, 8" Owner of Downstream Sewer Receiving Sewer Size The origin of this wastewater is (check all that apply): ❑ Residential Subdivision ❑ Apartments/Condominiums 0 Mobile Home Park ❑ School Restaurant ❑ Office ❑ Car Wash ❑ Institution ❑ Hospital ❑ Church Nursing Home Other (specify), Business Park 7. Volume of wastewater to be p rmatted in this project: 42,000 gallons per day of Downstrea % Domestic/Commercial 100 % Industrial % Other (specify): If the permitted flow is zero, indicate why: ❑ Interceptor Line - Flow will be permitted is subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected !RACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 Z H z 0 Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H ,0219(I) for item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(I)(3). 42 ac drainage basin • 10 people/arce for industrial park " 100GPDIperson = 42,000 GPD avg daily flow 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) 8 ENTER TOTAL LINE LENGTH IN MILES ary of Pump Stations to be Permitted (a Location ID Design Flow as shown on plans) (MGD) Length (feet) 2210 . ©.42 h additional sheets as necessary) Operational Point GPM TDH Gravity or Force Main (pull down menu) Gravity Gravity Gravity Gravity Gravity Gravity Gravity Power Reliability Option (dual line feed, permanent generator w/ATS, portable generator w/autodialer, wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? Z Yes El No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION Have the following permits/certifications been submitted forapproval? Wetland/Stream Crossings - General Permit or 401 Certification? 0 Yes 0 No N/A Sedimentation and Erosion Control Plan? 0 Yes 0 No N/A Stormwater? 0 Yes 0 No N/A rr A fl )I 1 PIF- itliCK APPL1CAT1ON for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 '1 ."--GSe the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 z (FAST -TRACK SEWER SYSTEMS)' to collect and record the stream classification data below (attach additional sheets a 0 necessary), This document is available from our web site or by contacting the appropriate Division of Water Quality regional office (see instructions for addresses) OR indicate the following: 0 A Watershed Classification is not needed because all parts of the project are at least 100 feet away from any down slope waterbody; AND, .... A Watershed Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Name of Waterbody Stream Waterbody Waterbody County River Basin Index Classification Afton Run Trib Cabarrus Yadkin 13-17-6-6 C Lto RSHED CL z 0 Location ID on Map 1 Submit the 8.5" x 11" topographic map as required in Instruction VI regardless of whether a classification is provided! la. Applicant's Certification: attest that this application for Business Blvd Sanitary Sewer has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application am not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being retumed as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-2156B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 awf/ls civil penalties uo 1525,000 per violation, ning Ifficial Sig ature 2. PrfessionaI Engineer's Certification: Date a that this application for Business Blvd Sanitary Sewer has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance, Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,0Qapormkgation, A " 2a. Wanda G. Fuller, PE Professional Engineer Name 2b. Concord Engineering & Surveying Engineering Firm 2c. PO Box 268 Address 2d. Concord City 2g. 704-786-5404 211. 704-786-7454 Telephone Facsimile 2e, NC 2f. 28026-0268 Zip 2i, „) wandafullerr'concordengineering Seal, Signature & Date 1.4 I A 01/111 i Park4 700 State of North Carolina Departt of Environment, Health, and Natural Resources Division of Environmental. Management 512 North Salisbury Street • Raleigh, North Carolina 27626-0535 , Governor GeorgeT. Everett, Ph.D. Directory, Jr., Secretary May 1,1991 Memorandum To: Delegated M unicipalti From: Steve W. Tedder, Chief Water Quality Secti Subject: Delegated Municipalities ist for Revised Non -Discharge Permit Applications The Division of Environmental Management's Water Quality Section has revised the Gravity Sewer Non -Discharge Permit Application Form. The form now incorporates the basic information that the Division feels is necessary in order for the delegated municipalities to perform a review on a gravity sewer project for the Division; therefore, the Division will no longer require that the "Delegated Municipalities Gravity Sewer Design Checklist" be completed and submitted We do, however, require that the delegated municipality perform the same type of review as always required and complete the bottom portion of this page and attach it as the last page of all gravity sewer questions applications that roc being submitted det dees legated d municipalities 73� g ties project. If you have any on this matter, please contact Mr. Randy DELEGATED MUNICIPALITY GRAVITY SEWER CERTIFICATION (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) Applicant: C tfY oFlev Project Name: CN . 6-AM ritsal Delegated l Tu;nicipality Reviewer's Certification: attest that the subject plans and specifications have been reviewed under my supervision and that those plans and specifications are consistent with the information that has been specified on the Non -Discharge Application and the Division of Environmental Management's minimum design requirements for gravity sewer projects. Delegated. Municipality Reviewer's NC Professional Entrginritr.eer's Registration No.: �ot, Seal and Signature (specify date): GAR0 FORM: DMGS 4191 PAGE 1 OF 1 WATER & SEWER AUTHORITY OF CABARRUS COUNTY a‘,1 , 2003 MAY 21 HO3 W, Brian Hiatt City Manager City of Concord P. Cl. Box 308 Concord, NC 28026-0308 Subject: Flow Acceptance Business Blvd Sewer Trunk Line Dear Mx. Hiatt: Office: 23.2 Davidson Hwy, Concord', NC 28027 Mad to: P.G. I3ox 428 Conc.:GT(1, NC 260264428 Phone: 754,766,17,6.3 Fw 704J95i564 OJECT NO. _a23_,„77-.012 This is in response to the subject request for flow acceptance received 5/16/0.3. The Water and Sewer Authority of Cabarrus County (WSACC) has or currently expects to be able to make available capacity at the Rocky River Wastewater Treatment Plant and appropriate sewer interceptors to transport and treat the wastewater from the proposed 364,000 sq. fi. .Minka :Building to be located in the International „Business Park Concord, NC. Approximately 2.,210: feet of 8-inch gravity sever is proposed to serve the project. WSACC agrees to accept wastewater from the proposed facility based on information provided by Concord Engineering & Surveying, Inc. (Civil Engineer for the project) using North Carolina .Department of Environment and Natural Resources (NCDENR) wastewater flow guidelines and the projected flow is 42,000 gpd. By requesting flow acceptance, the City of Concord acknowledges that WSACC may need to upgrade, expand, or construct new facilities to accommodate the increased flow volume granted by this and previous flow acceptance. Appropriate design and construction will be initiated when actual flows dictate but may be subject to situations that WSACC does not expect or control. Based upon flow of 42,000 gpd and cost of $8.126/gpd to provide treatment and transportation capacity, this flow acceptance represents an estimated capital expenditure in excess of S341,292. For your information and based upon NCDENR wastewater flow guidelines, WSACC has approved 10,914,238 gallons of flow acceptance for the City of Concord from 1992 to present and 166,805 gallons of flow acceptance year-to-date including this request. Based upon the approved flow acceptances WSACC has committed capacity valued in excess of S88,689,097 for the City of Concord since 1992 including S1,355,457 for this calendar year. Downstream facilities from the proposed project are scheduled in WSACC's current Capital Improvement Program (CIP) to increase available capacity. Projects on the CIP are subject to approval by WSACC's Board of .Directors, support :from local governing bodies, regulatory approval, and funding availability. The following schedule of CIPprojects is tentative and may be delayed by unforeseen circumstances: Rocky River Wastewater Treatment Plant Phase .11 upgrade. Scheduled completion date: 2004. Concord Business Blvd S ter Tinnk Line May 19, 2003 Page 2 of construction of this project is not tatted wit l one year of the date o is rescinded and a second request and approval i11 he required. Please no NA hen construction of this project is initiated. If you have any questions, please call meat (704) 7 -1 cc VS,A En inccring Staff Adam I a nhar oncord: Sherri Moore/Concord Wanda FullrESI Sicar;l, Exe Jo 1 C. Murdock,111 cnti Director apr-a1, the approval SACC ire « ritin Jaynes G. Mania. Governor William W. Cobey. Jr., Secretary Memorandum To: Delegated Municipalities From: Steve W. Tedder, Chief Water Quality Section State of North Carolina Department of Environment, Health, and Natural Resources Division of Environmental Management 512 North Salisbury Street • Raleigh, North Carolina 27626-0535 George T. Everett, Ph.D. Director May 1,1991 Subject: Delegated Municipalities Checklist for Revised Non -Discharge Permit Applications The Division of Environmental Management's Water Quality Section has revised the Gravity Sewer Non -Discharge Permit Application Form. The form now incorporates the basic information that the Division feels is necessary in order for the delegated municipalities to perform a review on a gravity sewer project for the Division; therefore, the Division will no longer require that the "Delegated Municipalities Gravity Sewer Design Checklist" be completed and submitted. We do, however, require that the delegated municipality perform the same type of review as always required and complete the bottom portion of this page and attach it as the last page of all gravity sewer applications that -. c being submitted as a delegated municipalities project. If you have any questions on this matter, please contact Mr. Randy Jones at 9191733-5083. DELEGATED hi[JNICIPALITY GRAVITY SEWER CERTIFICATION (THIS FORM MAYBE PHOTOCOPIED FOR USE AS AN ORIGINAL) Delegated Municipality Reviewer `s Certification: 1, V L attest that the subject plans and specifications have been reviewed under ray supervision and that those plans and specifications are consistent with the infoirnation that has been specified on the Non -Discharge Application and the Division of Environmental Management's minimum design requirements for gravity sewer projects. Delegated Municipality Reviewer's NC Professional Engineer's Registration No.w Seal and Signature (specify date): FORM: DOGS 4191 PAGE 1OF1