Loading...
HomeMy WebLinkAboutWQ0009826_Correction_20210420ROY COOPER Governor DIONNE DELLI-GATTI Secretary S. DANIEL SMITH Director KEVIN MCDANIEL — VICE PRESIDENT WAYNE FARMS LLC 4110 CONTINENTAL DRIVE OAKWOOD, GEORGIA 30566-4110 Dear Mr. McDaniel: NORTH CAROLINA Environmental Quality April 20, 2021 Subject: Permit No. WQ0009826 Correction Wayne Farms — Elkin Hatchery WWTF Wastewater Irrigation System Surry County In accordance with a written request received March 31, 2021 from Kevin Davidson, we are forwarding herewith corrected Attachments A and B of Permit No. WQ0009826 issued September 16, 2020. The corrections to the subject permit are as follows: The effluent sampling in Attachment A has been changed to reflect that there are multiple points prior to irrigation (PPIs) for different fields. PPI 001 has been changed to only report the total flow thru the treatment facility. PPI 002 has been added to sample the water being irrigated from the effluent storage pond dosing Fields 1 and 2. PPI 003 has been added to sample the effluent being irrigated from the storage tanks permitted in the September 16, 2020 modification to Fields 3 and 4. 2. The naming conventions of the fields added in the September 16, 2020 modification have been updated to match the names listed in the control panel and program. Please replace Attachments A and B of Permit No. WQ0009826 issued September 16, 2020 with the enclosed corrected Attachments. If you need additional information concerning this permit correction, please contact Erick Saunders at (919) 707-3659 or erickson.saunders&ncdenr.gov. Sincerely, S. Daniel Smith, Director Division of Water Resources Enclosure D E Q�� North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 11617 Mail Service Center I Raleigh, North Carolina 27699-1617 NORTH CAROLINA ng"rhn Mof E,.mw,,,.mW ausun 919.707.9000 Mr. Kevin McDaniel April 20, 2021 Page 2 of 2 cc: Surry County Health Department (Electronic Copy) Winston-Salem Regional Office, Water Quality Regional Operations Section (Electronic Copy) Kevin D. Davidson, PE — Agri -Waste Technology, Inc. (Electronic Copy) Beth Buffington — Protection and Enforcement Branch (Electronic Copy) Laserfiche File (Electronic Copy) Digital Permit Archive (Electronic Copy) ATTACHMENT A — LIMITATIONS AND MONITORING REQUIREMENTS PPI 001— Sweco Separator Flow Meter Effluent' Permit Number: WQ0009826 Version: 4.3 EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS PCs Parameter Description Units of Monthly Monthly Daily Minimum Daily Maximum Measurement Sample Code Measure Average Geometric Mean Frequency Type 50050 Flow, in Conduit or thru Treatment Plant GPD 5,000 Monthly Estimate 1. The permitted monthly flow limits shall be recorded at the Sweco separator flow meter prior to the transfer tanks. PPI 002 — WWTF Effluent — Storage Pond' EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS PCs Code Parameter Description Units of Measure Monthly Average Monthly Geometric Mean Daily Minimum Daily Maximum Measurement Frequency Sample Type 00310 BOD, 5-Day (20 °C) mg/L 3 x Year z,s Grab 00916 Calcium, Total (as Ca) mg/L 3 x Year z,s Grab 00940 Chloride (as Cl) mg/L 3 x Year 2,3 Grab 50060 Chlorine, Total Residual mg/L Weekly Grab 31616 Coliform, Fecal MF, M-FC Broth, 44.5 °C #/100 mL 3 x Year z,s Grab 50050 Flow, in Conduit or thru Treatment Plant GPD Monthly 3 Estimate 00927 Magnesium, Total (as Mg) mg/L 3 x Year z,s Grab 00610 Nitrogen, Ammonia Total (as N) mg/L 3 x Year z,s Grab 00625 Nitrogen, Kjeldahl, Total (as N) mg/L 3 x Year z,s Grab 00620 Nitrogen, Nitrate Total (as N) mg/L L3 x Year z,s Grab 00600 Nitrogen, Total (as N) mg/L 3 x Year z,s Grab 00400 pH su Weekly Grab 00665 Phosphorus, Total (as P) mg/L 3 x Year z,s Grab WQ09C Plant Available Nitrogen — Concentration mg/L 3 x Year z,s Calculated 00931 Sodium Adsorption Ratio ratio 3 x Year z,s Calculated 00929 Sodium, Total (as Na) mg/L 3 x Year z,s Grab 70300 Solids, Total Dissolved — 180 °C mg/L 3 x Year z,s Grab 00530 Solids, Total Suspended mg/L 3 x Year z,s Grab 1. This PPI is for effluent being sent to the storage pond that is used to irrigate for Fields 1 and 2 in Attachment B . 2. 3 x Year sampling shall be conducted in March, July, and November. 3. Sampling for Flow (PCs Code #50050) shall be measured from the transfer tank to the storage pond at Fields 1 and 2. WQ0009826 Version 4.3 Attachment A Page 1 of 2 PPI 003 - WWTF Effluent - Storage Tank' EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS PCs Code Parameter Description Units of Measure Monthly Average Monthly Daily Minimum Geometric Mean Daily Maximum Measurement Frequency Sample Type 00310 BOD, 5-Day (20 °C) mg/L 3 x Year z,s Grab 00916 Calcium, Total (as Ca) mg/L 3 x Year z,s Grab 00940 Chloride (as Cl) mg/L 3 x Year z,s Grab 50060 Chlorine, Total Residual mg/L Weekly 3 Grab 31616 Coliform, Fecal MF, M-FC Broth, 44.5 °C #/100 mL 3 x Year z,s Grab 50050 Flow, in Conduit or thru Treatment Plant GPD Monthly 3 Estimate 00927 Magnesium, Total (as Mg) mg/L 3 x Year z,s Grab 00610 Nitrogen, Ammonia Total (as N) mg/L 3 x Year z,s Grab 00625 Nitrogen, Kjeldahl, Total (as N) mg/L 3 x Year z,s Grab 00620 Nitrogen, Nitrate Total (as N) mg/L 3 x Year z,s Grab 00600 Nitrogen, Total (as N) mg/L 3 x Year z,s Grab 00400 pH su Weekly s Grab 00665 Phosphorus, Total (as P) mg/L 3 x Year z,s Grab WQ09C Plant Available Nitrogen — Concentration mg/L 3 x Year z,s Calculated 00931 Sodium Adsorption Ratio ratio 3 x Year z,s Calculated 00929 Sodium, Total (as Na) mg/L 3 x Year z,s Grab 70300 Solids, Total Dissolved — 180 °C mg/L 3 x Year z,s Grab 00530 Solids, Total Suspended In 3 x Year z,s Grab 1. This PPI is for effluent being sent to the storage tanks that are used to irrigate for Fields 3 and 4 in Attachment B. 2. 3 x Year sampling shall be conducted in March, July, and November. 3. Sampling for Flow (PCS Code #50050) shall be measured from the transfer tank to the storage tanks at Fields 3 and 4. Sampling for pH, Total Residual Chlorine, and Flow to the storage tank shall be collected from the transfer tank, while the remaining parameters collected from the irrigation headworks box. WQ0009826 Version 4.3 Attachment A Page 2 of 2 ATTACHMENT B — APPROVED LAND APPLICATION SITES AND LIMITATIONS Wayne Farms LLC — Wayne Farms — Elkin Hatchery WWTF Permit Number: WQ0009826 Version: 4.3 IRRIGATION AREA INFORMATION APPLICATION LIMITATIONS Field 4 Owner County Latitude Longitude Net Dominant Parameter Hourly Yearly Units Acreage Soil Series Rate Max 1 Wayne Farms LLC Surry 36.276518° -80.776023° 0.75 FeC2 — Fairview 01284 — Non -Discharge Application Rate 0.2 52 inches sandy clay loam WQ09 — Plant Available Nitrogen N/A 1582s lbs/acre 2 Wayne Farms LLC Surry 36.276345° -80.775900° 0.75 FeC2 — Fairview 01284 — Non -Discharge Application Rate 0.2 52 inches sandy clay loam WQ09 — Plant Available Nitrogen N/A 1582s lbs/acre 3 Zone 1 Wayne Farms LLC Surry 36.265945° -80.785986° 0.63 FeB2 — Fairview 01284 — Non -Discharge Application Rate 0.2 12.92 inches sandy clay loam WQ09 — Plant Available Nitrogen N/A 188 lbs/acre 3 Zone 4 Wayne Farms LLC Surry 36.265684° -80.785529° 0.60 FeB2 — Fairview 01284 — Non -Discharge Application Rate 0.2 13.58 inches sandy clay loam WQ09 — Plant Available Nitrogen N/A 188 lbs/acre 3 Zone 2 Wayne Farms LLC Surry 36.265367° -80.784936° 0.78 FeB2 — Fairview 01284 — Non -Discharge Application Rate 0.2 14.54 inches sandy clay loam WQ09 — Plant Available Nitrogen N/A 188 lbs/acre FeB2 — Fairview 01284 — Non -Discharge Application Rate 0.2 13.80 inches 3 Zone 5 Wayne Farms LLC Surry 36.265042° -80.784477° 0.82 sandy clay loam WQ09 — Plant Available Nitrogen N/A 188 lbs/acre 4 Zone 3 Wayne Farms LLC Surry 36.264839° -80.782104° 1.11 BbB — Braddock 01284 — Non -Discharge Application Rate 0.2 12.60 inches fine sandy loam WQ09 — Plant Available Nitrogen N/A 247 2,1 lbs/acre 4 Zone 6 Wayne Farms LLC Surry 36.264571° -80.782322° 1.18 BbB — Braddock 01284 — Non -Discharge Application Rate 0.2 12.07 inches fine sandy loam WQ09 — Plant Available Nitrogen N/A 3 247 lbs/acre Totals 6.62 Reporting shall be submitted on form NDMLR. Limits have been obtained from the North Carolina State University Realistic Yield Expectations (RYE) calculator (https://realisticyields.ces.ncsu.edu/) using the soil types (FeB2, FeC2, and BbB) and a cover crop of Fescue (Hay). The applicant may petition for a permit modification to apply above agronomic rates if predictive calculations are provided that demonstrate State groundwater standards will be protected (15A NCAC 02T .0505(c)). Compliance with this application limit has been suspended until April 1, 2021. Any exceedances of the 12-month floating PAN limit caused by applications prior to this date shall be suspended as long as no further application occurs after this date until such point as the 12-month floating total is no longer exceeded. Field names have been updated to match the installed control panel. The following table provides the current and former field names for reference on original plan sheets. Current Field Name Former Field Name 1 1 2 2 3 Zone 1 3A1 3 Zone 4 3A2 3 Zone 2 3B1 3 Zone 5 3B2 4 Zone 3 4A1 4 Zone 6 4B2 WQ0009826 Version 4.3 Attachment B Page 1 of 1 THIS PAGE BLANK