HomeMy WebLinkAboutWQ0036362_Regional Office Historical File Pre 2018FAST TRACK EN6INEERING CERTIFICATION APR 0 5 .:10013 Permittee: Town of Taylorsville Permit No. WQ0036362 Project: Dollar General Sewer Extension Issue Date: 02/2012013 Complete and submit this form to the permit issuing regional office with the following: • One copy of the project record drawings (plan & profile views and detail drawings of sewer lines) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) in pdf format, Record drawings should indicate the design and the marked up changes during construction. • Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project • Changes to the project should be dearly identified on the record drawings or in written summary form, Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. Modifications should be submitted prior to certification. This project shall not be considered complete nor allowed to operate until the Division has received this Engineer's Certification and all required supporting documentation. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. PERMITTEE'S CERTIFICATION I, David Odom , the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted here r portions thereof, David Odom, Town Manager 04402/17.004---' Printed Name, Title Si ature Date ENGINEER'S CERTIFICATION El Partial Final I, Justin Church , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe periodically, 0 weekly, 0 full time) the construction of the subject project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit, 15A NCAC 02T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, and other supporting materials. North Carolina Professional Engineer's Seal, signatmtiqnd date: SS SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS SURFACE WATER PROTECTION SUPERVISOR MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, LAVQ Use 0e1): 1low from this projccr kmibutary lo: NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Pat McCrory Charles Waklld, P, E. Governor Director February 20, 2013 David Odom, Town Manager Town of Taylorsville 67 Main Avenue Drive Taylorsville, NC 28681 Subject: Permit No. W003634-6 , Town of Taylorsville Dollar General Sewer Extension Wastewater Collection System Extension Alexander County Dear Mr. Odom: John Skvarla, Ill Secretary In accordance with your application received February 4, 2013,.we are forwarding herewith Permit No. WQ0036362, dated February 20, 2013, to the Town of Taylorsville for the construction and operation of the subject wastewater collection system extension. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the conditions and limitations as specified therein. This cover letter and supplement shall be considered a part of this permit and are therefore incorporated therein by reference. Please pay particular attention to the following conditions contained within this permit: Condition 11.4: Requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2T .0403 or any individual system -wide collection system permit issued to the Permittee. It shall be responsibility of the Town of Taylorsville to ensure that the as -constructed project meets the appropriate design criteria and rules, Failure to comply may result in penalties in accordance with North Carolina General Statute §143-21.5.6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. 1617 Mail Service Centers Raleigh, North Carolina 27699.1617 Location: 512 N. Salisbury Si- Raleigh, North Carolina 27604 Phone: 9194 07 63001 FAX, 919-807-6492 Internet. www nrwalerquallty.oq An Equal Opportunity t Affirmalbre Acllmn E inployer One NorthCarttna mature!! David Odom February 20, ;201. Page Two if you need additional infer ion concerning this rraatter, please contact Michael P 2194 or via e-mail atMichael,Parker@ncrienrigov Electronic coy:.lustin Church, P.E. cc: MMlooresville Region Water Quality Centra PERCS (electronic copy) for Charles Wakild, P.E.D Division of Water by Michael Parker Mooresville Region Surface Water duality Supervisor !fflc, Surface y 1 Files ction Section ~ STATE OFNORTH CARDUNA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OFENVIRONMENT AND NATURAL RESOURCES WASTEWATER COLLECTION SYSTEM EXTENSION PERK4ff in accordance with the provisions of Article 21 of Chapter 143' General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Town ofTay|onvUe ,Alexander County for the construction and operation of approximately 579 linear feet of 8-inch gravity sewer to serve the Dollar General Sewer Extension, and the discharge of 1,390 gallons per day of collected domestic wastewater into the Town of Taylorsvi|[e's existing sewerage system, pursuant to the application received February 4, 2013, and in conformity with 15A NCA[ 2T; the Division's Gravity Sewer Minimum Design Criteria adopted February 12^ 1996 a:s applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered apart ofthis permit. This permit shaU be effective from the date ofissuance until rescinded and shall be subject tothe specified conditions and limitations contained therein, Permit issued this the 20"' day of'February, 2013. for Charles VVakib,P.E,Director Division ufWater Quality By Authority of The Environmental Management Commission Permit NunmbmnVVQQU36362 SUPPLEMENT TO PERMIT COVER SHEET Town of Taylorsville is hereby authorized to: Construct, and then operate upon certification the aforementioned wastewater collection extension, The sewage and wastewater collected by this system shall be treated in the Town of Taylorsville's Wastewater Treatment Facility prior to being discharged into the receiving stream. Permitting of this project does not constitute an acceptance of any part of the project that does not meet 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina -licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as -constructed project meets the appropriate design criteria and rules. Construction and operation is contingent upon compliance with the Standard Conditions and any Special Conditions identified below. SPECIAL CONDITIONS If, at any time, the additional wastewater flow volume made tributary to this sewer extension is believed to exceed the value permitted herein, a modification shall be requested for this permit from the Division of Water Quality to properly allocate the subject wastewater flow, No flow in excess of the quantity permitted herein, 1,390 GPD, shall be made tributary to the subject sewer system until an application for permit modification for an increase in flow has been submitted to and approved by the Division of Environmental Management. By copy of this per rrtit, the Alexander County Building Inspections Department is hereby notified that building or occupancy permits shall only be issued for the (number of residences — only refer to # of bedrooms if an approved flow reduction is used) as part of the PROJECT NAME project until a modified permit is issued by the Division indicating additional connections, 4. By copy of this permit, the Alexander County Health Department and the Alexander County Building Inspections Department are advised that, no certificates of occupancy are to be granted prior to the submittal of a sealed engineer's certification, IL STANDARD CONDITIONS This permit shall not be transferable. In the event there is a desire for the wastewater collection facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 2. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 4. The wastewater collection facilities shall be properly maintained and operated at all times, The Permittee shall maintain compliance with an individual system -wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2T .0403, If an individual permit i not required, the following performance criteria shall be met as provided in 15A NCAC 2T.0403: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. b. A map of the sewer system shall be developed and shall be actively rnairttained. c. An operation and maintenance plan including pump station inspection frequency, preventative maintenance schedule, spare parts inventory and overflow response has been developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day (Le. 365 days per year). Pump stations that are connected to a telemetry system shall be inspected at least once per week. High -priority sewer lines shall be inspected at least once per every six -months and inspections are documented, A general observation of the entire sewer system shall be conducted at least once per year. Overflows and bypasses shall be reported to the appropriate Division regional office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute §143-215.1C. h. A Grease Control Program is in place as follows: For public owned collection systems, the Grease Control Program shall include at least biannual distribution of educational materials for both commercial and residential users and the legal means to require grease interceptors at existing establishments. The plan shall also include legal means for inspections of the grease interceptors, enforcement for violators and the legal means to control grease entering the system from other public and private satellite sewer systems. 2. For privately owned collection systems, the Grease Control Program shall include at least bi-annual distribution of grease education materials to users of the collection system by the permittee or its representative, 3. Grease education materials shall be distributed more often than required in Parts (1) and (2) of this Subparagraph if necessary to prevent grease -related sanitary sewer overflows. Right-of-ways and easements shall be maintained in the full easement width for personnel and equipment accessibility. Documentation shall be kept for Subparagraphs (a) through (i) of this Rule for a minimum of three years with exception of the map, which shall be maintained for the life of the system, 5 Noncompiance Notification: The Permittee shall report by telephone to a water quality staff member at the Mooresville Regional Office, telephone number (704) 663-1699, as soon as possible., but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc; or b. Any SSO and/or spill over ,1,.000 gallons; or c. Any ,SSO and/or spill, regardless of volume, that reaches surface water Voice mail messages or faxed information is permissible, but this shall not be considered as the initial verbal report. Overflows and spills occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 8,58-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing and submitting Part I of Form CS-SSO (or the most current Division approved form) within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur, Part 11 of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control., 6. Construction of the gravity sewers, pump stations, and force mains shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State, 7, Per 15A NCAC 2T.0116, upon completion of construction and prior to operation of these permitted facilities, the completed Engineering Certification form attached to this permit shall be submitted with the required supporting documents to the address provided on the form, A complete certification is one where the form is fully executed and the supporting documents are provided as applicable, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. If the permit is issued to a private entity with an Operational Agreement, then a copy of the Articles of Incorporation. Declarations/Covenants/Restrictions, and Bylaws that have been appropriately filed with the applicable County's Register of Deeds office shall be submitted with the certification. A complete certification is one where the form is fully executed and the supporting documents are provided as applicable. Supporting documentation shall include the following: a. One copy of the project construction record drawings (plan & profile views of sewer lines & force rnains) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) and are defined as the design drawings that are marked up or annotated with after construction information and show required buffers, separation distances, material changes, etc. b. One copy of the supporting pump station design calculations (selected pumps, system curve, operating point, buoyancy calculations, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project. c. Changes to the project that do not result in non-compliance with this permit, regulations, or the Minimum Design Criteria should be clearly identified on the record drawings, on the certification in the space provided, or in written summary form. Prior to Certification (Final or Partial): Permit modifications are required for any changes resulting in non- compliance with this permit (including pipe length increases of 10% or greater, increased flow, pump station design capacity design increases of 5% or greater, and increases in the number/type of connections), regulations, or the Minimum Design Criteria. Requested modifications or variances to the Minimum Design Criteria will be reviewed on a case -by -case basis and each on its own merit: Please note that variances to the Minimum Design Criteria should be requested and approved during the permitting process prior to construction. After -construction requests are discouraged by the Division and may not be approved, thus requiring replacement or repair prior to certification & activation. 8. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 9. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2T; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes .§143-215,6A through §143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina -licensed Professional Engineer to the licensing board. 10. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 11. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B ,0200 and 15A NCAC 2H ,0500. FAST TRACK ENGINEERING CERTIFICATION Permittee: Town of Taylorsville Permit No. WQ0036362 Project: Dollar General Sewer Extension Issue Date: 02/20/2013 Complete and submit this form to the permit issuing regional office with the following: ▪ One copy of the project record drawings (plan & profile views and detail drawings of sewer lines) of the wastewater collection system extension. Final record drawings should be clear on the plans or on digital media (CD or DVD disk) in pdf format. Record drawings should indicate the design and the marked up changes during construction. Supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project ▪ Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. Modifications should be submitted prior to certification. This project shall not be considered complete nor allowed to operate until the Division has received this Engineers Certification and all required supporting documentation. Therefore, it is highly recommended that this certification be sent in a manner thatprovides proof of receipt by the Division. PERMITTEE'S CERTIFICATION the undersigned agent for the Permittee, hereby state that this project has been constructed pursuant to the applicable standards & requirements, the Professional Engineer below has provided applicable design/construction information to the Permittee, and the Permittee is prepared to operate & maintain the wastewater collection system permitted herein or portions thereof. Printed Name, Title Signature ENGINEER'S CERTIFICATION Date El Partial 11 Final , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (El periodically, [1] weekly, full time) the construction of the subject project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit: 15A NCAC 02T, the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable: the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engi eer's Seal, signature, and date: SEND THIS FORM & SUPPORTING DOCUMENTATION VVITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS SURFACE WATER PROTECTION SUPERVISOR MOORESVILLE REGIONAL OFFICE 610 EAST CENTER AVENUE, SUITE 301 MOORESVILLE, NC 28115 The Permittee is responsible for tracking all partial certifications up until a final certification is received, Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions, DWQ Use Only: How frolIt this project is tributt :y to: USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! ), OwnerfPermittee: la. Town of Taylorsville Full Legal Name (company, municipality, HOA„ utility, etc.) lb David Odom, Town Manager Signing Official Name and Title (Please review The legal entity who will o ❑ Individual ❑ Federal ld. 67 Main Avenue Drive • Mailing Address Z to 1c lf. NC _..._ State Application Number: (to be completed by DWQ) A NCAC 2T 0106 (b or authorized signing officials n this system is: Municipality ❑ State/County 0 Private Partnership © Corporation D ©the l h 828-632-2218 1 i. 828-632-7964 Telephone Facsimilery 2. Project (Facility) information: 2a, Dollar General Sewer Extension Brief Project Name (permit will refer to this name) Contact Person: 3a, Justin Church, PE — Project Engineer— Blue Ridge Environmental Consultants Name and Affiliation of Someone Who Can Answer Questions About this Application 3b, 336-844-4088 Phone Number Project is El New ❑ Modifi 2. Owner is jj Public (skip to Item 8(3)) 2a. If private, applicant will be: 0 Retaining Ownership (i.e, store, church, single office, etc.) or ❑ Leasing units (lots, townhomes, etc, - skip to Item B(3)) • Selling units (lots, townhomes, etc. - go to Item B(2b)) 3. Town of Taylorsville n existing permit) ❑ Private 3c. justin@a brec.b'iz E-mail Modification, Permit No.: go to Item 2(a)) 1 e, Taylorsville City 1g, 2.8681 Zip Code 1j. townmanager E-mail 2b. Alexander_ pepi County Where Project is Located 2b. If sold, facilities owned by a (must choose one) 0 Public Utility (Instruction C) ❑ Homeowner Assoc./Developer (Instruction D) Owner of Wastewater Treatment Facility (VVVVTF) Treating Wastewater From This Project 4a. Town of Taylorsville Wastewater Treatment Plant 4b. 0026271 Name of WWTF WWTF Permit No. Town of Taylorsville `5b. 8" ® Gravity Owner of Downstream Sewer Receiving Sewer Size ❑ Force Main The origin of this wastewater is (check all that apply): Residential Subdivision ❑ Apartments/Condominiums • Mobile Home Park ❑ School ❑ Restaurant ❑ Office Permit # of Downstrea ® Retail (Stores, shopping centers) • Institution ❑ Hospital ❑ Church • Nursing Home ❑ Other (specify): 7. Volume of wastewater to be allocated or permitted for this particular project *Do not include future flows or previously permitted allocations 8. If the permitted flow is zero, indicate why: Sewer (Instruction E) 100 % Domestic/Commercial % Industrial (attach description.) (RO: contact your Regional Office Pretreatment staff) % Other (specify): 0 gallons per day O Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No.. ❑ Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FTA12107 PF9PP'PPIPPF-, Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 for the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7), Values other than that in 15A NCAC 2T 0114 (b) and (c) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2T .0114 (f). Retail w/o food service = 100 gpd/1000 sq ft = 100 x 9,1 = 910 gpd Residential = 120 gpd/bedroom = 120 x 4 = 480 gpd Total = 910 + 480 = 1390 gpd 10. Summary of Sewer Lines to be Permitted (attach additionat sheets if necessary) Size (inches) 8 Length (feet) New Gravity or Additional Force Main 579 New Gravity CI 1 1 Summary of Pump Stations wl associated Force Mains to be Permitted (attach additional sheets as necessary) L1.11 Pump Station Location ID (self chosen - as shown on plans/map for reference) i.". Design Flow Operational Point Power Reliability Option (MGD) GPM ©TDH 1 -permanent generator wiATS; Force Main Size Force Main Length 2 - portable generator w/MTS 0 2 f."*. Pump Station Location ID (self chosen - as shown on plans/map for reference) Design Flow Power Reliability Option Operational Point .. (MGD) permanent generator w/ATS; Force Main Size Force Main Length GPM @TDH 2 - portable generator w/MTS 0 Pump Station Location ID (self chosen - as shown on plans/map for reference) Design Flow Power Reliability Option Operational Point . - (MGD) 1permanent generator wIATS; Force Main Size Force Main Length GPM @TDH 2 - portable generator wfMTS 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? [I] Yes E No If Yes, permit number of 2nd treatment facility (RO — if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? El Yes E] No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA12/07 lave the following permits/certifications been submitted for approval for the system or project to be served? Wetland/Stream Crossings - General Permit or 401Certification? 0 Yes 0 No N/A Sedimentation and Erosion Control Plan? 1Z Yes 0 No 0 N/A Stormwater? El Yes 0 No N/A 15, Does this project include any high priority lines, [see 15A NCAC 02T ,0402 (2)] involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: [2] and provide details 1, Owner/Permittee*s Certification: (Signature of Signing Official and Project Name) 1, David Odom , attest that this application for Dollar General Sewer Extension has been reviewed by me and is accurate and complete to the best of my knowledge, 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215,6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation, /— 2 043 Signi Signature Date ENGINEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMI I I AL OF THIS APPLICATION, THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIMITY in TO OTHER UTILITIES, DESIGN CALCULATIONS, ETC. REFER TO 15A NCAC 02T 0305 0 Professional Engineer's Certification: {Signature of Design Engineer and Project Name) 1, Justin Church , attest that this application for Dollar General Sewer Extension has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although other professionals may have developed certain portions of this submittal package, inclusion of Mese materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215,6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25, 000 per violation, 2a. Justin Church Professional Engineer Name 2b, Blue RidatEnvironmental Consultants, PA Engineering Firm 2c. 1305 S Collegiate Drive Mailing Address 2d, Wilkesboro 2g City Telephone 2e, NC 2f 28697 Facsimile E-mail C Clf‘ 1/1) NC RE S al gnature & Date FTA12/07 State of North Carolina Department of Environment and Natural Resources Division of Water Quality Flow Tracking/Acceptance for Sewer Extension Permit Applications (F-rsE --10/07) Project Applicant Name: Town of Tavlorsville Project Name for which flow is being requested: Dollar General Sewer Extension More than one FTSE-Ioso7 may be required for a single protect the owner of the WWTP is not responsible fOr all pump stations along the route of the proposed wastewater flow, 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Town of Tavlorsville Wastewater Treatment Plant h. WWTP Facility Permit #: 0026271 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of pennitted flow used All :flows are in MGD 0.83 MGD 0 MGD 0,3,7 MGD 0,00139 MGD 0.37139 MGD 44.7 ?""i) II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station Name Approx. Capacity, MGD Approx. Current Avg. (Firm/Design) Daily: Flow, MGD Jav Drive Pump Station 0.72 MGD 0,06 MGD HI. Certification Statement: 1, David Odom certify that, to the hest of my knowledge, the addition of the volume of wastewater to be permitted in this project has been evaluated along the, route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving :treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections 1 and It for which in the responsible party. Signature of this form indicates acceptance of this wastewater flow. / .2--",/3 Signing (?/ficiaI Signature Date FORM WSCAS-03/2012 WATERSHED CLASSIFICATION ATTACHMENT FOR SEWER SYSTEMS licit t Name Town of Taylorsville Pr t fesslonal Engineer Name Justin Church ation ID Name of Waterbod UT to Lower Little River Project Name Dollar General Sewer Extension County Alexander t®ineerng Firrri ue Ridge Environ River Basin Catawba ental Consultants, PA aterbody Stream Index No, -59-10.5) Waterbody Classification If unnamed, indicate "unnamed tributary to X", where Xis the named waterbody to which the unnamed tributary joins. l certify that as a Registered Professional Engineer in the State of North Carolina that i have diligently followed the Division's instructions for classifying waterbodies and that the above classifications are inclusive of the stated project, complete and correct to the best of my knowledge and belief. PE Seal, Signature and Date *** END OF FORM `S .7.AS-03/2012 *** FORM: WSCAS-03/20 Page 1 of 1 rtNurnber 0036362 Central Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Fa ,t roc Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer michael. parker Coastal SW Rule Permitted Flow 1390 Facility° Facility Name Dollar General Sewer Extension Location Address Owner Owner Name Town of Taylorsville Date(Ev Orig Issue 02/20/13 App Received Draft Initiated ©2/©4/13 Regulated Activities Retail Subdivision Wastewater collection Duffel! Waterbody Name Scheduled Issuance les. AP S SVVP_ 02/20/13 Version Permit Classification 1.60 Individual Permit Contact Affiliation Major/Minor Region Minor Mooresville County Alexander Facilit t Contact Affiliation Owner Type Government - Municipal Owner Affiliation David Matthew Robinette 204 Main Ave Dr Taylorsville NC 28681 Public Notice Issue Effective 02/20/13 02/20/13 Requested!Received Events Additional information requested Additional information received Expiration Stream Index Number Current Class Subbasin BLUE RIDGE ENVIRONMENTAL CONSULTANTS, PA PH. 828-265-4425 467 CALLOWAY GAP RD WEST JEFFERSON, NC 28694-9209 142.2 US Hwy 4211-M P©, box 892 • PIT, 338-913-99�18 Wilkesboro, NC= 289.97 • o f •G 66-1284-531 ARS 11,