HomeMy WebLinkAboutSW8960315_HISTORICAL FILE_20040528STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW_kY(Pl%`�, DOC TYPE El CURRENT PERMIT [-]'APPROVED PLANS HISTORICAL FILE COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD State Stormwater Management Systems Permit No. SW8 960315 Modification STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Pointe @ North Market, LLC North Market Promenade New Hanover County FOR THE construction, operation and maintenance of a wet detention pond in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until May 28, 2014, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described on page 3 of this permit, the Project Data Sheet. The stormwater control has been designed to handle the runoff from 63,400 square feet of impervious area. 3. The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans. 4. All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements. The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans. 5. The runoff from all built -upon area within the pennitted drainage area of this project must be directed into the permitted stormwater control system. A permit modification must be submitted and approved prior to the construction of additional built -upon area from outside of the approved drainage area. 2 State Stormwater Management Systems Permit No. SW8 960315 Modification DIVISION OF WATER QUALITY PROJECT DESIGN DATA SHEET Project Name: Permit Number: Location: Applicant: Mailing Address: Application Date: Receiving Stream/River Basin: Stream Index Number: Classification of Water Body: Drainage Area, acres: Onsite, sq. ft.: Offsite, sq. ft.: Total Impervious Surfaces, sq. ft.: Pond Depth, feet: TSS removal efficiency: Permanent Pool Elevation, FMSL: Permitted Surface Area, sq. ft.: Permitted Storage Volume, cubic ft.: Temporary Storage Elevation, FMSL: Controlling Orifice: Permitted Forebay Volume, cubic fl.: North Market Promenade SW8 960315 Modification New Hanover County Mr. Blaine East Pointe @ North Market, LLC 206 Sherwood Forest Place Cary, NC 27519 May 28, 2004 Spring Branch / Cape Fear 18-74-63-1 "C Sw" 1.92 83,636 none 63,400 7.5 90% (no filter is required) 34.50 2,193@Permanent Pool 5,718 36.60 1" � (drawdown in 2-5 days) n/a (not required at time of ssuance of original permit) 3 State Stormwater Management Systems Permit No. SW8 960315 Modification I1. SCHEDULE OF COMPLIANCE The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface. 2. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 3. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of slopes and the vegetated filter. d. Immediate repair of eroded areas. e. Maintenance of all slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of outlet structure, orifice device, flow spreader, catch basins and piping. g. Access to the outlet structure must be available at all times. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. Decorative spray fountains will be allowed in the stormwater treatment system, subject to the following criteria: a. The fountain draws its water from less than 2' below the permanent pool surface. b. Separated units, where the nozzle, pump and intake are connected by tubing, may be used only if they draw water from the surface in the deepest part of the pond. The falling water from the fountain must be centered in the pond, away from the shoreline. d. The maximum horsepower for the fountain's pump is based on the permanent pool volume. The maximum pump power for a fountain in this pond is 118. 6. The facilities shall be constructed as shown on the approved plans. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 7. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. A modification may be required for those deviations. 8. If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. 9. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: 4 State Stormwater Management Systems Permit No. SW8 960315 Modification a. Any revision to any item shown on the approved plans, including the stonrwater management measures, built -upon area, details, etc. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area or to the drainage area. e. Further subdivision, acquisition, or sale of all or part of the project area. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. 10. The permittee shall submit final site layout and grading plans for any permitted future areas shown on the approved plans, prior to construction. If the proposed BUA exceeds the amount permitted under this permit, a modification to the permit must be submitted and approved prior to construction. 11. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction. 12. At least 30 days prior to the sale or lease of any portion of the property, the permittee shall notify DWQ and provide the name, mailing address and phone number of the purchaser or leasce. An access/maintenance casement to the stormwater facilities shall be granted in favor of the permittee if access to the stormwater facilities will be restricted by the sale or lease of any portion of the property. 13. The permittee must maintain compliance with the proposed built -upon area and ensure that the runoff from all the built -upon is directed into the permitted system. 14. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. 15. The permittee must maintain the current permitted drainage area. No additional runoff from outside of the permitted drainage area boundary may enter the permitted stormwater facilities without first applying for and receiving a permit modification. III. GENERAL CONDITIONS 1. This permit is not transferable except after notice to and approval by the Director. In the event of a change of ownership, or a name change, the permittee must submit a formal permit transfer request to the Division of Water Quality, accompanied by a completed name/ownership change form, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. State Stormwater Management Systems Permit No. SW8 960315 Modification 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility. 6. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 9. The permittee shall notify the Division any name, ownership or mailing address changes within 30 days. Permit issued this the 28th day of May 2004. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission 6 x State Stormwater Management Systems Permit No. SW8 960315 Modification North Market Promenade Stormwater Permit No. SW8 960315 Modification New Hanover County Designer's Certification 1, as a duly registered in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form is included in the Certification. Noted deviations from approved plans and specification: SEAL Signature Registration Number Date State Stormwater Management Systems Permit No. SW8 960315 Modification Certification Requirements: 1. The drainage area to the system contains approximately the permitted acreage. 2. The drainage area to the system contains no more than the permitted amount of built -upon area. 3. All the built -upon area associated with the project is graded such that the runoff drains to the system. 4. The outlet/bypass structure elevations are per the approved plan. 5. The outlet structure is located per the approved plans. 6. Trash rack is provided on the outlet/bypass structure. 7. All slopes are grassed with permanent vegetation. 8. Vegetated slopes are no steeper than 3:1. 9. The inlets are located per the approved plans and do not cause short-circuiting of the system. 10. The permitted amounts of surface area and/or volume have been provided. IL . Required drawdown devices are correctly sized per the approved plans. 12. All required design depths are provided. 13. All required parts of the system are provided, such as a vegetated shelf, and a forebay. 14. The overall dimensions of the system, as shown on the approved plans, are provided. cc: NCDENR-DWQ Regional Office New Hanover County Building Inspections .R: �•' 1 STORMWATER AND EROSION CONTROL CALCULATIONS NORTH MARKET PROMENADE 5500 MARKET STREET WILMINGTON, NORTH CAROLINA For Pointe @ North Market, LLC 206 Sherwood Forest Place Cary, NC 27519 (919) 362-1700 April 2004 Prepared by. ANDREW & KUSKE CONSULTING ENGINEERS, INC. 902 Market Street Wilmington, North Carolina 28401 (910) 343-9653 (910) 343-9604 (Fax) E-mail: office@andrewandkuske.com I A & K Project No. 04034 Date Design Andrew and Kuske �Z1104- `�G� 902 Market 5t. CONSULTING ENGINEERS. INC. Wilmington. N.C. 28401 >of Check Job --� 17Z:" For 41CW-N .-s�ir� c , ,— Job No. �I..'� ,,,�, /�'l/1�rt-r/%o �S'i9.��✓`� i7`n/.ta �js�,✓y/N�i G�._C --. oet-E""��� Off. �.. rc ,� � � � 77?"� G- � •� sue' ��1"'Tfi c�r� .ram-� 7— /f)� iIGL•�,C'�' r'�'/io dJ.�/G�"�u�f �✓rGG- fi'� �-�-•�avi ti.� S 17"r-- /..T' I C 1-7 / T .C) [//✓ fl c > :T/S ' v� a o/sue iC -777 ca,,/, �r � S`i/72E7 i � I r C��P�/�.+"� ���.-;�'�s reJ' �`r`.."�s 2 a e.••-i ���''�."1�.•�� C. �..r�/►•.1/t�.lCrr", 77b %d-.J �' � G--c�L ITT�4 -�/1• /T�J/� G lTif O� G�/C�•�/ JiV C✓'Z.�� it� r-L7 L�.�/Ti'��_:.- � `�..f'.�'�"- � f h..ar?Y�J G' �� , ?/��'� I� ray C.,,.�•�/ �"r ..'�. 6 T- J".'7v rL..r�-r �T'".rL. �-/C... /1/-� �"7l-�.J��' �f�" �"�•',�.ri7..JG ,t��..Jr..� I /Z F.�� ��_ ram"/%� r 'I .-�i�/i� ii✓c .�. �. �,;/'�� /� .oE� �i`- f3 y ra,~S`-a' !?a � ✓ /'iI /�lv?i✓ /ac. � �.��-�,L,�„ l"'0 G% .�� ��%i �-�/%�:� G-G ��,%f•�",fr---- p � � X /.�77 i..�G .�/r• �'� ✓-1�y7.. ,�" f%�l'r2�/G / ��.JL �"�'�V s] ! �" ram.• ',�/ I ifv'� r.r✓ r r'�--r /='✓ -c-/t-�.{1' �i'it- sg' '�-r lJ�r�'/n//'� /9:1� v�=� L� UL✓...T, ���-Cr�/ /i'�/�r.�-✓!v.✓.f i 'F X /'s' ii 'A . e; ,.-"/.i orp ✓+7, i'f I Date Design ' Andrew and Kuske sheet 902 Market St. CONSULTING ENGINEERS, INC. Wilmington, N,C, 28401Of Check Job _r`i 7z5l� /rn � .(�✓�t�� cr For IVut_ 7;L-/ /y L�jG,� .fob No. I/�./iQ���7rT"l)a /%bra •"�4i.J/;t?'.%;. d qto Z� i /7Sq� ,�E��/ I /Z�/Yi'o ��✓� �/� /z"��G /Y�,�-fir 7— ?o 7n-L - ✓�-7 � sty✓lcvf' rR.�F" ell- 1 wit ca,�-y 7?'97 G- .� 7TlL-r Si���vi �v✓�7.7�� i I SITE DATA TABLE I USE: ZONING: PARCEL ID: MAP ID: SITE AREA: DISTURBED AREA: CAMA LAND USE: BUILDING SETBACKS: R ESTAU RANT/OFFICE/R ETAI L RB R05009-005-023-000 314814226679000 1.92 ACRES 2.86 ACRES DEVELOPED RB: FRONT SETBACK: 50' SIDE: 50', 8' ADJACENT -TO SERVICE LANE REAR SETBACK: 15' BUILDING HEIGHT: I IRREGULAR, 22' - 30'. SEE FOUNDATION PLANTINGS REQUIRED PARKING: RESTAURANT WITH 90 SEATS: 1 /2.5 SEATS MAX, 1 /4 SEATS MIN. E 36 MAX., 23 MIN. RESTAURANT WITH 150 SEATS: 1 /2.5 SEATS MAX, 1 /4 SEATS MIN. 60 MAX., 38 MIN. OFFICE ® 3800 SF: 1 /250 SF MAX, 1 /400 SF MIN. 15 MAX., 10 MIN. RETAIL ® 12,152 SF- 1/225 SF MAX, 1/400 SF MIN. 54 MAX., 30 MIN. TOTAL REQUIRED PAR IKING: 165 MAX., 101 MIN. TOTAL PARKING PROVIDED: 105 SPACES INCLUDES 5 HC SPACES IMPERVIOUS AREA: BUILDING E ASPHALT%CU&GUTTER SIDEWALKS/CORBNCRETE TOTAL IMPERVIOUS IAREA: PERCENT IMPERVIOUS: NEW IMPERVIOUS AREA EXISTING IMPERVIOU`: AREA REMOVED AND RI�PLACED: LANDSCAPING: FOUNDATION PLANTINGS: 18,500 SF (ROOF AREA) 42,400 SF 2,500 SF 63,400 SF TOTAL 76% 37,500 SF FRONT: 29X 115'E X .12 = 400 SF READ. (511 PROVD.) NORTH SIDE: 30' X 135' X .12 = 486 SF READ. (487 PROVD.) SOUTH SIDE: 24' X� 127' X .12 = 366 SF READ. (424 PROVD.) REAR NORTH TO SOUTH: 23' X 75' X A 2 --' 207 SF READ. (N/A) 30' X 66' X .12 237 SF READ. (N/A) 27' X 100' X .12 IT 324 SF READ. (N/A) 22' X 60' X .12 158 SF READ. (N/A) 22' X 46' X .12 1 121 SF READ. (N/A) I LANDSCAPING REQ'D INTERIOR (8%) STREETYARD LANDSCAPING: PRIMARY: MARKET ST, 12.5' STREETYARD REQUIRED 398' - 36' X 12.5' ' 4,525 SF SECONDARY: EASTWOOD RD. 6.25' STREETYARD REQUIRED 318' - 24' X 6,25' = 1,838 SF 3,392 SF 3,392 SF PROVIDED 4,100 SF PROVIDED 1,838 SF PROVIDED Date Design Andrew and Kuske leet 9/zi�O4 `:9P(:-777- 902 Market St. CONSULTING ENGINEERS, INC. Wilmington, N.C. 28401 Check Job f,7y?i"E- S-7D,,s- sic-UiJ7�i2 For /./z�� 7:y ✓ - _S77?T� ���-r•s[.✓�?T� 2.._ �.y! one-rl?'T'7�.-�J ��'� Cry-�•���T77ca /r.f /� � '�'/% �� %� g � � 0315� ✓�'/a a/Fi>"�t77 ate•/ / G /,J" o 7— _r"�'z� � , r-r�-✓r7'r�2. �''✓c��f � y✓�G c /�../ C ��.. rJ �". 777� ✓�" Ci G �. Cs L.�..J J�•.� G ,ego c✓I'l- ff iJ G J' 7VA-,-Z- 6, 1f'7 9 ��C_. �oN ,eG-F C--"' e::nr.Je s�e� ,per... D77'1 eb 777 r� z�ao/ 4/ oo ..s.=-- 2.I 9 3 S•� y of 04024Promenade Type 11124-hr 10 Yr. Storm Rainfall=7.00" Prepared by Andrew & Kuske Consulting Engineers, Inc. HydroCAD® 7.01 sln 000479 © 1986-2004 Applied Microcomputer Systems 4/21/2004 Stage -Area -Storage for Pond 2P: Existing Pond Elevation Surface Storage feet s -ft(cubic-feet) '&Pe- 34.50 2,193 0 G&vrncl-j 34.55 2,217 116 34.60 2,242 231 34.65 2,266 347 34.70 2,290 463 34.75 2,315 579 34.80 2,339 694 34.85 2,363 810 34.90 2,387 926 34-95 2,412 1,042 35.00 2,436 1,157 35.05 2,462 1,292 35.10 2,488 1,427 35.15 2,514 1,562 35.20 2,540 1,696 35.25 2,566 1,831 35.30 2,592 1,966 35.35 2,618 2,101 35.40 2,644 2,235 35.45 2,670 2,370 35.50 2,696 2,505 35.55 2,721 2,640 35.60 2,747 2,775 35.65 2,773 2,909 35.70 2,799 3,044 35.75 2,825 3,179 35.80 2,851 3,314 35.85 2,877 3,448 35.90 2,903 3,583 35.95 2,929 3,718 36.00 2,955 3,853 36.05 2,980 4,013 36.10 3,005 4,173 36.15 3,029 4,333 36.20 3,054 4,493 36.25 3,079 4,653 36.30 3,103 4,813 36.35 3,128 4,974 36.40 3,153 5,134 36.45 3,178 5,294 36.50 3,203 5,454 rr�7E 36.55 3,227 5,614 36.60 y�]G*�J36-65 _ 3,252 5,774 3,277 5,934 36.70 3,302 6,095 36.75 3,326 6,255 36.80 3,351 6,415 36.85 3,376 6,575 36.90 3,400 6,735 36.95 3,425 6,895 37.00 3,450 7,055 37.05 3,482 7,244 Elevation feet Surface s -ft Storage cubic -feet 37.10 3,515 7,433 37.15 3,547 7,621 37.20 3,580 7,810 37.25. 3,613 7,999 37.30 3,645 8,188 37.35 3,678 8,377 37.40 3,710 8,565 37.45 3,743 8,754 37.50 3,775 8,943 37.55 3,807 9,131 37.60 3,840 9,320 37.65 3,872 9,509 37.70 3,905 9,698 37.75 3,938 9,887 37.80 3,970 10,075 37.85 4,003 10,264 37.90 4,035 10,453 4,068 10,642 037.95 38.00 4,100 10,830 -r1f V9 Date Design NORRIS, KUSKE & TUNSTALL Sheet 902Market St. CONSULTING ENGINEERS, INC, Wilmington, N.C.28401 pt Check Job For Job No. . 4`T rvc-C-.-� Aaa (34,.5b'j=f 7-0 7Z,, J 7-ZI/L e-7 r97- e2!:;L777b -w - (2.7' ) =- 47 6S'F 5`7b�r-•^� �✓�I� ?E".� =p�c.E ai4-"� -.1KC4 4-7— Apo rTb .wt �-�• vac_ �.-y .� � ! 7 4- � �- q g 1 c �, s '� � J /76 8 0 775T7TL V4'e -vim e = /L//7'7G ri' AJl;tr ^1Dr` J�6?6 k /Da = 7, 6 / 56 7.sOs- - RyCEIVED MAY 2 8 2004 Dwe _fig 6 '0�- ii -7 .'841 A".' o%"' Date Design Andrew and Kuske Sheet 902 Market St. CONSULTING ENGINEERS, INC. Wilmington, N.C. 28401 Of Check Job S•TiTJ-�— .S7X,17-r-g For n/pO-7W Job No. Z-- OD ,"0 -S7?a't-'9 G /O G v r-3.: , S7 / 8 3 �vp2��'Z-.. .�r.�C� ' .�.� G•-�•c� C.-ti,J %�'-•,�".� :- 3q . S� /z/ 93 SF .f 7,-t f c..i.�.�t: ,C� ..S"r.°rt.. ,.%�y� �it..�` �! r'�'T" r•✓rd'dw �"7�4�'._ /�"Z:�':. � 2 / 7'S s/ =' /�fr5r ® 7, S 10e Tom! i9 T Nan- .-*- -Tz. d� � 90 424, x = �� x - 7v `7o YZ -76 dh' sc� — 7co J .�� •- ©. cam"? �, a � �..3, G 36 Dote Design Andrew and Kuske S eet 902 Market St. CONSULTING ENGINEERS, INC. Wilmington, N.C. 28401 O1 Check Job Sr. + J' .S��-.--7d .a'i �'� For nIo 7'7 / Job No. m ��o l/Il�� !J-Sv/z�iT�� �x.�-i�i - .�1 '-i✓o.�/1��tG /�00/ - 2'/ t/� S'� � C.9 G G sr" �i7 `C X o •'r-/<=�G .r . �. o�T �/r,�G,-� Ll s Z 7,)7-e'-' Zve el +V4 �✓ti/ O iC J iG fo ,rL �� �c�/it�/J "2EQv/.-, 46-'�J sTb�-AGE = Sb 2 / r--T -3 7Zc.o C z -) 4 �%'7 rJn �'.._.r1r� c ,��/ = / 7 Z-/ g or3 T��►l � _. S6 �� � / 72 / g o� sGr �C_ s Date Design Andrew and Kuske �i%)Ic el.. _7 CONSULTING ENGINEERS, INC. 902 Market St. Wilmington, N.C. 28401 Yet Of i Check Job G-i7•r� o n��cr�r. rl For �p,C �� yjy�--- Job No. G/7� Si?2 .—T L✓/T7 r�XL r G vG-TT)0rul CMG v�rr"�/� %1�.T,� � d �.� ✓ �f � �/�-i...� 0e9e716" 90-7� 4-,,.1 7�1 -7, 6 = 7. .o er "' l4:)� /L'0 v %% /mod F'?'. C O y+/ ,�"�l /f" ��a/G /..cur•..//✓ ,..='r!�/- �.��� �'�....../, /a� 2 S~ Date Design Andrew and Kuske Sheet 1 902 Market St, CONSULTING ENGINEERS, INC, Wilmington, N.C. 28401 Of Check JobC/7�,O/,� �✓jG/`7iNGT��J For /✓A�i7%�Y!/l'f—/�Gg� Job No. c—K-IMIti"/sic-Qrn ;.�.�er- C;Z4v2¢ .ybrZ­: .may R' o t• ..fG r1' �cs .-roc �l-r .O 4 et- 77T-, nra oN riTE /Ji/>E ��IGc vc�x+.v1�o .77772f= �-o �,Ei?zL ..S�lb+4--s"?f'• /�-� /PiTYP�/i�4 �`� a r�1G f1/ �T�i' /9 U��t,/�9`C� die E� /�7iT•�-� vo . /9 i.G`Jf elf/G�..i,�rJ �p--�- %�-•� 2�Tz-{�T.� -6Z-c-;lZK: n/G 0 07- oC7,0C�rI 7-r- f'r�° CMG d,.G. I 0'% - r.� < . 77 (3S) C.O.W. Proposed Area 4P C.O.W. Existing Pond Evaluation 1S Existing Impervious Site 2P Area Existing Pond Subcat Reach on Link 04024Promenade Type 11124-hr 10 Yr. Storm Rainfall=7.00" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 25 HydroCADO 7.01 sln 000479 c0 1986-2004 Applied Microcomputer Systems 4/21/2004 Time span=11.00-15.00 hrs, dt=0.01 hrs, 401 points Runoff by SCS TR-20 method, UH=SCS Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Subcatchment 1S: Existing Impervious Site Area Subcatchment 3S: C.O.W. Proposed Area Runoff Area=1.920 ac Runoff Depth=3.61" Tc=5.0 min CN=84 Runoff=11.71 cfs 0.578 of Runoff Area=0.860 ac Runoff Depth=4.24" Tc=5.0 min CN=98 Runoff=6.12 cfs 0.304 of Pond 2P: Existing Pond Peak Elev=37.87' Storage=10,356 cf Inflow=11.71 cfs 0,578 of Outflow=6.35 cfs 0.422 of Pond 4P: C.O.W. Existing Pond Evaluation Peak Elev=37.33' Storage=8,285 cf Inflow=6.12 cfs 0.304 of Outflow=1.14 cfs 0.158 of Total Runoff Area = 2.780 ac Runoff Volume = 0.882 of Average Runoff Depth = 3.81" 04024Promenade Type /// 24-hr 10 Yr. Storm Rainfall=7.00" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 26 HydroCADO 7.01 sln 000479 © 1986-2004 Applied Microcomputer Systems 4/21 /2004 Subcatchment IS: Existing Impervious Site Area Runoff = 11.71 cfs @ 12.07 hrs, Volume= 0.578 af, Depth= 3.61" Runoff by SCS TR-20 method, UH=SCS, Time Span= 11.00-15.00 hrs, dt= 0.01 hrs Type III 24-hr 10 Yr. Storm Rainfall=7.00" Area (ac) CN Description 1.460 98 Paved parking & roofs 0.460 39 >75% Grass cover, Good, HSG A 1.920 84 Weighted Average Tc Length Slope Velocity Capacity Description min feet ftlft ftlsec cfs 5.0 Direct Entry, Subcatchment 1S: Existing Impervious Site Area Hydrograph 13 ©Runoff 12" 11.71 cfs 0 12.07 hrs F: ---------------- ...._----____-- _----Type-lll--24-ht.-10-Yr:-Storm-- _-_-----_...____.__----.-----____.Rainfall=7:00" ........... ........ .Runoff-Area=1:920 ac.. '................ . R'urtioff Volume=0:578 of 7- Runo De''th' 161 . 1— 3 s 6- " ... _ .,. .,.,.. t ; Tc=5.0 min LL 5= C N =84 4 3 " 2- " 11 12 13 14 15 Time (hours) 04024Promenade Type Ill 24-hr 10 Yr. Storm Rainfall= 7. 00" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 27 HydroCAD® 7.01 sln 000479 © 1986-2004 Applied Microcomputer Systems 4/21/2004 Subcatchment 3S: C.O.W. Proposed Area Runoff = 6.12 cfs @ 12.07 hrs, Volume= 0.304 af, Depth= 4.24" Runoff by SCS TR-20 method, UH=SCS, Time Span= 11.00-15.00 hrs, dt= 0.01 hrs Type III 24-hr 10 Yr. Storm Rainfall=7.00" Area (ac) CN Description _ ^' 0.860 98 New Paved parking & roofs Tc Length Slope Velocity Capacity Description (min) (feet)_- (ft/ft) ftlsec (cfs)_ - 5.0 Direct Entry, L Subcatchment 3S: C.O.W. Proposed Area Hydrograph -- ....... _------------------ - -- ...... ------------ ..._-------.. Type III 24-hr 10 Yr. Storm Rainfall=7.00" Runoff Area=0.860 ac Runoff.. Volume=0.304..af.... Runoff Depth=4.24" ...._..Tc=5.0 min.... CN=98 11 12 13 1A Time (hours) 15 p Runofi 04024Promenade Type 11124-hr 10 Yr. Storm Rainfall=7.00" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 28 HydroCADO 7.01 sln 000479 © 1986-2004 Applied Microcomputer Systems 4/21/2004 Pond 2P: Existing Pond Inflow Area = 1.920 ac, Inflow Depth = 3.61" for 10 Yr. Storm event Inflow = 11.71 cfs @ 12.07 hrs, Volume= 0.578 of Outflow = 6.35 cfs @ 12.18 hrs, Volume= 0.422 af, Atten= 46%, Lag= 6.8 min Primary = 6.35 cfs. @ 12.18 hrs, Volume= 0.422 of Routing by Stor-Ind method, Time Span= 11.00-15.00 hrs, dt= 0.01 hrs Peak Elev= 37.87' @ 12.18 hrs Surf.Area= 4,018 sf Storage= 10,356 cf Plug -Flow detention time= 54.0 rein calculated for 0.422 of (73% of inflow) Center -of -Mass det. time= 28.7 min ( 774.7 - 746.0 ) # Invert Avail.Storage Storage Description 1 34.50' 10,830 cf Custom Stage Data (Prismatic) Listed below Elevation Surf.Area Inc.Store Cum,Store (feet) (sq-ft) (cubic -feet) (cubic -feet) 34.50 2,193 0 0 35.00 2,436 1,157 1,157 36.00 2,955 2,696 3,853 37.00 3,450 3,203 7,055 38.00 4,100 3,775 10,830 # Routing Invert Outlet Devices 1 Primary 34.50' 15.0" x 313.0' long 15" Outfall Pipe RCP, square edge headwall, Ke= 0.500 Outlet Invert= 33.42' S= 0.0035 T n= 0.012 Cc= 0.900 2 Device 1 34.50' 1.0" Vert. Orifice/Grate C= 0.600 3 Device 1 36.60' 1.00' x 0.30' Vert. Orifice/Grate C= 0.600 4 Device 1 37.40' 16.0' long x 1.0' high Sharp -Crested Rectangular Weir 2 End Contraction(s) Primary OutFlow Max=6.34 cfs @ 12.18 hrs HW=37.87' (Free Discharge) L =15" Outfall Pipe (Barrel Controls 6.34 cfs @ 5.2 fps) 2=OrificelGrate (Passes < 0.05 cfs potential flow) 3=OrificelGrate (Passes < 1.53 cfs potential flow) =Sharp -Crested Rectangular Weir (Passes < 17.96 cfs potential flow) O r� 04024Promenade Type !l! 24-hr 10 Yr. Storm Rainfall=7.00" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 29 H droCAD® 7.01 s/n 000479 © 1986-2004 AeRlied Microcomputer Systems 4/21/2004 Pond 2P: Existing Pond Hydrograph -----------------..-------.-.--_,--. -------- -.....----------- -------- ,._.......... ...__................ -------------- - ----- 13 Inflow 10 primary 1171 crs 12- ........ Inflow Area=1.920„ac... ............... ............. ;............. Peak Elev=37:87' 10................ . " .......... .. . .......................... ......... ......,......... ...... ......... .''I ........ -.I......... ..1 .... i{• _ ...... .......... Storage ,356.c 8- 97. ., w D 6.95 cls 12.10 hrs 3 0 6- 5- 4: .. ... .-. ......, 1- 0 11 12 13 14 15 Time (hours) 04024Promenade Type 11124-hr 10 Yr. Storm Rarnfaf1=7.00" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 30 HydroCADO 7.01 sln 000479 ® 1986-2004 Applied Microcomputer Systems _ 4/21/2004 Pond 4P: C.O.W. Existing Pond Evaluation Inflow Area = 0.860 ac, Inflow Depth = 4.24" for 10 Yr. Storm event Inflow = 6.12 cfs @ 12.07 hrs, Volume= 0.304 of Outflow = 1.14 cfs @ 12.50 hrs, Volume= 0.158 af, Atten= 81 %, Lag= 25.8 min Primary - 1.14 cfs @ 12.50 hrs, Volume= 0.158 of Routing by Stor-Ind method, Time Span= 11,00-15.00 hrs, dt= 0.01 hrs Peak Elev= 37.33' @ 12.50 hrs Surf.Area= 3,662 sf Storage= 8,285 cf Plug -Flow detention time= 80.7 min calculated for 0.158 of (52% of inflow Center -of -Mass det. time= 48.7 min ( 791.4 - 742.7 ) # Invert Avail.Stora e Storage Description 1 34.50' 10,830 cf Custom Stage Data (Prismatic) Listed below Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) (cubic -feet) _ 34.50 2,193 0 0 35.00 2,436 1,157 1,157 36.00 2,955 2,696 3,853 37.00 3,450 3,203 7,055 38.00 4,100 3,775 10,830 # Routing Invert Outlet Devices 1 Primary _ 34.50' 15.0" x 313.0' long Culvert RCP, square edge headwall, Ke= 0.500 Outlet Invert= 33.42' S= 0.0035 '1' n= 0.013 Cc= 0.900 2 Device 1 34.50' 1.0" Vert. Orifice/Grate C= 0.600 3 Device 1 36.60' 1.00' x 0.30' Vert. Orifice/Grate C= 0.600 4 Device 1 37.40' 16.0' long x 1.0' high Sharp -Crested Rectangular Weir 2 End Contraction(s) Primary OutFlow Max=1.14 cfs @ 12.50 hrs HW=37.33' (Free Discharge) t--1=Culvert (Passes 1.14 cfs of 5.41 cfs potential flow) Orifice/Grate (Orifice Controls 0.04 cfs @ 8.0 fps) 1:3=Orifice/Grate (Orifice Controls 1.09 cfs @ 3.6 fps) Sharp -Crested Rectangular Weir ( Controls 0.00 cfs) 04024Promenade Type 11124-hr 10 Yr. Storm Rainfall=7.00" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 31 HydroCAD® 7.01 sln 000479 © 1986-2004 Applied Microcomputer Systems 4/21/2004 Pond 4P: C.O.W. Existing Pond Evaluation Hydrograph FO s_lz cts 12.D7 hrs " Primary { Inflow Area=0.860 ac 6- — r Peak Elev-37:33 5- Storage=8,285 cf --------------------------------------- ------ U 3 LL 3- -------------- ✓._....__.................. ...-...- - 2- .._..._,._.. 1.14 Cf5 12,50 hrs 11 12 13 14 15 Time (hours) 04024Promenade Type 11124-hr 25 Yr. Storm Rainfall=8.05" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 32 HydroCADO 7.01 sln 000479 O 1986-2004 Applied Microcomputer Systems _ 4/21/2004 Time span=11.00-15.00 hrs, dt=0.01 hrs, 401 points Runoff by SCS TR-20 method, UH=SCS Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Subcatchment 1S: Existing Impervious Site Area Subcatchment 3S: C.O.W. Proposed Area Runoff Area=1.920 ac Runoff Depth=4.28" Tc=5.0 min CN=84 Runoff=13.88 cfs 0.685 of Runoff Area=0.860 ac Runoff Depth=4.88" Tc=5.0 min CN=98 Runoff=7.04 cfs 0.349 of Pond 2P: Existing Pond Peak Elev=57.68' Storage=10,830 cf Inflow=13.88 cfs 0.685 of Outflow=17.02 cfs 0.524 of Pond 4P: C.O.W. Existing Pond Evaluation Peak Elev=37.47' Storage=8,826 cf Inflow=7.04 cfs 0.349 of Outflow=2.24 cfs 0.203 of Total Runoff Area = 2.780 ac Runoff Volume = 1.035 of Average Runoff Depth = 4.47" qI 04024Promenade Type 111 24-hr 25 Yr. Storm Rainfall=8.05" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 33 HydroCADO 7.01 sln 000479 O 1986-2004 Applied Microcomputer Systems 4/21/2004 Subcatchment 1S: Existing Impervious Site Area Runoff - 13.88 cfs @ 12.07 hrs, Volume= 0.685 A Depth= 4.28" Runoff by SCS TR-20 method, UH=SCS, Time Span= 11.00-15.00 hrs, dt= 0.01 hrs Type III 24-hr 25 Yr. Storm Rainfall=8.05" Area (ac) CN Description 1.460 98 Paved parking & roofs 0.460 39 >75% Grass cover, Good, HSG A 1.920 84 Weighted Average Tc Length Slope Velocity Capacity Description (min) (feet) (ftlft) ftlsec) cfs 5.0 Direct Entry, Subcatchment 1S: Existing Impervious Site Area Hydrograph 15: ❑ Runofi ... .................. 13.88 Us W 12.07 hre................... .-.... .........--.,,,,....... ....,.-.... ,,................. 14-: ...................... ........._...,...Type III-24-hr;-25-Yr. Storm-' 13= -------------------- ----------------------------------------------------- — A� Y Rainfall 8:05" 12= ..- -_..___------ Runoff Area=1 920 ac 1Q_ . '' Runoff..Volume=0.685-af 9 ---------------- R ff D h— 4.28- 0 8_ ............... . Tc=5:0..min LL.......-- ........... ..................... ................... �........... i......... .............. ....... ,. s................... ................... ............ .......... .................C.N.=84 5: 4= 3= 2- 1- 0- 11 12 13 14 15 Time (hours) 04024Promenade Type /// 24-hr 25 Yr. Storm Rainfall=8.05" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 34 HydroCADO 7.01 s/n 000479 © 1986-2004 Applied Microcomputer Systems 4/21/2004 Subcatchment 3S: C.O.W. Proposed Area Runoff = 7.04 cfs @ 12.07 hrs, Volume= 0,349 A Depth= 4.88" Runoff by SCS TR-20 method, UH=SCS, Time Span= 11.00-15.00 hrs, dt= 0.01 hrs Type III 24-hr 25 Yr. Storm Rainfall=8.05" Area (ac) CN Description 0.860 98 New Paved parking & roofs Tc Length Slope Velocity Capacity Description (min) _ (feet) (ft/ft) eft/sec] cfs) - 5.0 Direct Entry, Subcatchment 3S: C.O.W. Proposed Area Hydrograph 6- " 5- U --------------------------- - 4- , 0 LL - 2- " ---------------------- o- 11 p R�nofi Type III 24-h'r 25 Yr. Storm Rainfall=8:05"--- Runoff Area=0.860 ac _- - _.-----------.._. __- ------ ---------------------- I ---------- --------- .. Runoff Volume=0.349 of .......... --------- .__..._._ .__...---...__.._Runoff .Depth=4.88".._ Tc=5.0 min CN=98--. 13 14 Time (hours) 15 04024Promenade Type 11! 24-hr 25 Yr. Storm Rainfa#=8.05" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 35 H droCAD® 7.01 sln 000479 c0 1986-2004 Applied Microcomputer Systems 4/21/2004 Pond 2P: Existing Pond Inflow Area = 1.920 ac, Inflow Depth = 4.28" for 25 Yr. Storm event Inflow = 13.88 cfs @ 12.07 hrs, Volurne= 0.685 of Outflow - 17.02 cfs @ 12.11 hrs, Volume= 0.524 af, Atten= 0%, Lag= 2.3 min Primary = 17.02 cfs @ 12.11 hrs, Volume= 0.524 of Routing by Star -Ind method, Time Span= 11.00-15.00 hrs, dt= 0.01 hrs Peak Elev= 57.68' @ 12.11 hrs Surf.Area= 4,100 sf Storage= 10,830 cf Plug -Flow detention time= 48.5 min calculated for 0.524 of (76% of inflow) Center -of -Mass det. time= 25.0 min ( 770.4 - 745.4 ) #f - Invert Avail.Storage Storage Description 1 34,50' 10,830 cf Custom Stage Data (Prismatic) Listed below Elevation Surf.Area Inc.Store Cum.Store feet s -ft(cubic-feet) cubic -feet 34.50 2,193 0 0 35.00 2,436 1,157 1,157 36.00 2,955 2,696 3,853 37.00 3,450 3,203 7,055 38.00 4,100 3,775 10,830 # Routing Invert Outlet Devices 1 Primary 34.50' 15.0" x 313.0' long 15" Outfall Pipe RCP, square edge headwall, Ke= 0.500 Outlet Invert= 33.42' S= 0.0035 '/' n= 0.012 Cc= 0.900 2 Device 1 34.50' 1.0" Vert. Orifice/Grate C= 0.600 3 Device 1 36.60' 1.00' x 0.30' Vert. Orifice/Grate C= 0.600 4 Device 1 37.40' 16.0' long x 1.0' high Sharp -Crested Rectangular Weir 2 End Contraction(s) Primary OutFlow Max=16.88 cfs @ 12.11 hrs HW=57.35' (Free Discharge) L1=15" Outfall Pipe (Barrel Controls 16.88 cfs @ 13.8 fps) 12=Orifice/Grate (Passes < 0.13 cfs potential flow) 3=Orifice/Grate (Passes < 6.56 cfs potential flow) -Sharp-Crested Rectangular Weir (Passes < 12,043.91 cfs potential flow) 04024Promenade Type /// 24-hr 25 Yr. Storm Rainfall=8.05" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 36 HydroCADO 7.01 sln 000479 © 1986-2004 Applied Microcomputer Systems 4/21/2004 Pond 2P: Existing Pond Hydrograph ................ ... .... ._.. ......... .......... .. ,9 _'. Primary •' . ........... 7702 cfs 1211his ............. Inflow• Area=1-:920. ac-. . - 177 .............. _ ........ :.._ ,98207hrs .....................Elegy=57.68 kf, Peak 15 -----.... --•- ----,.------ t-•----- ; Storage=10;830 cf... 13 .......................... ......................... —_......... . ,2 3.T �... ............ ......... ..... .. ...... .. ............ . ..... ....-........... 8. 7- ........ .............. .................... .... ........ .................. ..... .. -----— ---- --- .--------__.«._ - B'. ..................... 5, .................. .... ................ .................. ,,.................. . liti! 111111�Ijg III '!III Time {hours} 23 1 111 04024Promenade Type 11124-hr 25 Yr. Storm Rainfall=8.05" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 37 HydroCADO 7.01 sin 000479 © 1986-2004 Applied Microcomputer Systems 4/21/2004 Pond 4P: C.O.W. Existing Pond Evaluation Inflow Area = 0.860 ac, Inflow Depth = 4.88" for 25 Yr. Storm event Inflow = 7.04 cfs @ 12.07 hrs, Volume= 0.349 of Outflow = 2.24 cfs @ 12.35 hrs, Volume= 0.203 af, Atten= 68%, Lag= 16.7 min Primary = 2.24 cfs @ 12.35 hrs, Volume= 0.203 of Routing by Stor-Ind method, Time Span= 11.00-15.00 hrs, dt= 0.01 hrs Peak Elev= 37.47' @ 12.35 hrs Surf.Area= 3,755 sf Storage= 8,826 cf Plug -Flow detention time= 74.6 min calculated for 0.203 of (58% of inflow) Center -of -Mass det. time= 44.4 min ( 787.2 - 742.7 ) # Invert Avail.Stora a Storage Description 1 34.50' 10,830 cf Custom Stage Data (Prismatic) Listed below Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) ubic-feet 34.50 2,193 0 0 35.00 2,436 1,157 1,157 36.00 2,955 2,696 3,853 37.00 3,450 3,203 7,055 38.00 4,100 3,775 10,830 # Routing Invert Outlet Devices 1 Primary 34.50' 15.0" x 313.0' long Culvert RCP, square edge headwall, Ke= 0.500 Outlet Invert= 33.42' S= 0.0035 T n= 0.013 Cc= 0.900 2 Device 1 34.50' 1.0" Vert. Orifice/Grate C= 0.600 3 Device 1 36.60' 1.00' x 0.30' Vert. Orifice/Grate C= 0.600 4 Device 1 37.40' 16.0' long x 1.0' high Sharp -Crested Rectangular Weir 2 End Contraction(s) Primary OutFlow Max=2.22 cfs @ 12.35 hrs HW=37.47' (Free Discharge) L =Culvert (Passes 2.22 cfs of 5.55 cfs potential flow) 2=04ficelGrate (Orifice Controls 0.04 cfs @ 8.2 fps) 3=Orifice/Grate (Orifice Controls 1.22 cfs @ 4.1 fps) =Sharp -Crested Rectangular Weir (Weir Controls 0.96 cfs @ 0.9 fps) 04024Promenade Type I// 24-hr 25 Yr. Storm Rainfall=8.05" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 38 HydroCAD® 7,01 s/n 000479 © 1986-2004 Applied Microcomputer Systems 4/21/2004 Pond 4P: C.O.W. Existing Pond Evaluation Hydrograph i -- - - - -- 7_p4cls 12.o7hm ._...,.., ................................... .... .. ❑r Pmary Inflow Area=0.860 ac f---------------------------- Peak EIev=37.47' St 26 f ------------ --------- -- ------ orage=8�8. c 5-< �r U 4. U. 3., ...-..__------- - ---------------- ----`--------------------------------`-. 224 Us 0 12.35 hes 2- 1- 11 12 13 14 15 Time (hours) 04024Promenade Type 11124-hr 50 Yr. Storm Rainfall=9.00" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 39 HydroCADO 7.01 sln 000479 © 1986-2004 Applied Microcomputer Systems 4/21/2004 Time span=11.00-15.00 hrs, dt=0.01 hrs, 401 points Runoff by SCS TR-20 method, UH=SCS Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Subcatchment 1S: Existing Impervious Site Area Subcatchment 3S: C.O.W. Proposed Area Runoff Area=1.920 ac Runoff Depth=4.89" Tc=5.0 min CN=84 Runoff=15.83 cfs 0.782 of Runoff Area=0.860 ac Runoff Depth=5.45" Tc=5.0 min CN=98 Runoff=7.88 cfs 0.391 of Pond 2P: Existing Pond Peak Elev=57.95' Storage=10,830 cf Inflow=15.83 cfs 0.782 of Outflow=17.07 cfs 0.615 of Pond 4P: C.O.W. Existing Pond Evaluation Peak Elev=37.51' Storage=8,998 cf Inflow=7.88 cfs 0.391 of Outflow=3.37 cfs 0.243 of Total Runoff Area = 2.780 ac Runoff Volume =1.173 of Average Runoff Depth = 5.06" �G q 04024Promenade Type 11124-hr 50 Yr. Storm Rainfall=9.00° Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 40 HydroCAD® 7.01_ sin 000479 © 1986-2004 Ap hied Microcomputer Systems _ 4/21/2004 Subcatchment 1S: Existing Impervious Site Area Runoff = 15.83 cfs @ 12.07 hrs, Volume= 0.782 af, Depth= 4.89" Runoff by SCS TR-20 method, UH=SCS, Time Span= 11.00-15.00 hrs, dt= 0.01 hrs Type 111 24-hr 50 Yr. Storm Rainfall=9.00" Area (ac) CN Description 1.460 98 Paved parking & roofs 0.460 39 >75% Grass cover, Good, HSG A 1.920 84 Weighted Average Tc Length Slope Velocity Capacity Description (min) (feet) (ftlft) (ftlsec) {cfs) 5.0 Direct Entry, Subcatchment 1S: Existing Impervious Site Area Hydrograph 1s' .,� 5.t53 CIS 15.. ...... ...................... 14= " 13' ' ............................. 12: ............... .......... 9= " .......... _ I ............. 7' 6= 5 4 3= 2 1� i� ------- .---V1�1��lY °,-........-...._...................-.,..............;..................,.,.,.,.,.,.,.,.,...,.,.,.,.,.,.....,.,. 13 14 15 Time (hours) 21 0f 04024Promenade Type Il124-hr 50 Yr. Storm Rainfall=9.00" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 41 HydroCAD® 7,01 sln 000479 © 1986-2004 Applied Microcomputer Systems 4/21/2004 Subcatchment 3S: C.O.W. Proposed Area Runoff = 7.88 cfs @ 12.07 hrs, Volume= 0.391 af, Depth= 5.45" Runoff by SCS TR-20 method, UH=SCS, Time Span= 11.00-15.00 hrs, dt= 0.01 hrs Type Ili 24-hr 50 Yr. Storm Rainfall=9.00" Area (ac) CN Description 0.860 98 New Paved parking & roofs Tc Length Slope Velocity Capacity Description (min) (feet) (ftlft) (_ftlsec) 5.0 _ Direct Entry, Subcatchment 3S: C.O.W. Proposed Area Hydrograph � RunoFf MN w 5- U O 4_ LL - - - - - - - - - - - 11 12 13 14 15 Time (hours) �7 Of I 04024Promenade Type Ill 24-hr 50 Yr. Storm Rainfall=9.00" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 42 HydroCAD® 7.01 sln 000479 @ 1986-2004 Applied Microcomputer Systems 4/21/2004 Pond 2P: Existing Pond Inflow Area = 1.920 ac, Inflow Depth = 4.89" for 50 Yr. Storm event Inflow - 15.83 cfs @ 12.07 hrs, Volume= 0.782 of Outflow = 17.07 cfs @ 12.07 hrs, Volume= 0.615 af, Atten= 0%, Lag= 0.0 min Primary - 17.07 cfs @ 12.07 hrs, Volume= 0.615 of Routing by Stor-Ind method, Time Span= 11.00-15.00 hrs, dt= 0.01 hrs Peak Elev= 57.95' @ 12.07 hrs Surf.Area= 4,100 sf Storage= 10,830 cf Plug -Flow detention time= 44.0 min calculated for 0.613 of (78% of inflow) Center -of -Mass det. time= 22.0 min ( 767.1 - 745.0 ) # Invert Avail.Storage Storage Description 1 34.50' 10,830 cf Custom Stage Data (Prismatic) Listed below - Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) (cubic -feet) 34.50 2,193 0 0 35.00 2,436 1,157 1,157 36.00 2,955 2,696 3,853 37.00 3,450 3,203 7,055 38.00 4,100 3,775 10,830 # Routing Invert Outlet Devices 1 Primary 34,50' 15.0" x 313.0' long 15" Outfall Pipe RCP, square edge headwall, Ke= 0.500 Outlet Invert= 33.42' S= 0.0035 'I' n= 0.012 Cc= 0.900 2 Device 1 34.50' 1.0" Vert. Orifice/Grate C= 0.600 3 Device 1 36.60' 1.00' x 0.30' Vert. Orifice/Grate C= 0.600 4 Device 1 37.40' 16.0' long x 1.0' high Sharp -Crested Rectangular Weir 2 End Contraction(s) Primary OutFlow Max=17.07 cfs @ 12.07 hrs HW=57.86' (Free Discharge) L1=15" Outfall Pipe (Barrel Controls 17.07 cfs @ 13.9 fps) 12=Orifice/Grate (Passes < 0.13 cfs potential flow) 3=OrificelGrate (Passes < 6.64 cfs potential flow) -Sharp-Crested Rectangular Weir (Passes < 12,624.38 cfs potential flow) T 04024Promenade Type III 24-hr 50 Yr. Storm Rainfall=9.00" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 43 HydroCAD® 7.01 sln 000479 c0 1986-2004 Applied Microcomputer Systems 4/21/2004 Pond 2P: Existing Pond Hydrograph 19 ---------- _---------;..._..-------- -----------------._---- - Inflow 13 Primary 17,07 Cf3 A 12.07 hrS .... . Inflow Area=1.920 ac 17- 1fi �s — ---- • --P - 15:" 14- a' Storage-1 U;83� cf ... 13- ' .• . t 1 12� u10 ........................ `....... .......... ......... .................. ......... .............. cg.: ................ ..... ................. _ a .............. .. ............ ......... .......... ............. ... LLfi" ........ ...................... 7_ , 6. . . ......... .. ... . ... .... ....... 5 : ., .., ., . 4: 3- 2,i 1- 0 11 12 13 14 15 Time (hours) 04024Promenade Type 11124-hr 50 Yr. Storm Rainfall=9.00" Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 44 HydroCADO 7.01 sin 000479 © 1986-2004 Applied Microcomputer Systems _ 4/21/2004 Pond 4P: C.O.W. Existing Pond Evaluation Inflow Area = 0.860 ac, Inflow Depth = 5.45" for 50 Yr. Storm event Inflow - 7.88 cfs @ 12.07 hrs, Volume= 0.391 of Outflow = 3.37 cfs @ 12.24 hrs, Volume= 0.243 af, Atten= 57%, Lag= 10.1 min Primary = 3.37 cfs @ 12.24 hrs, Volume= 0.243 of Routing by Star -Ind method, Time Span= 11.00-15.00 hrs, dt= 0.01 hrs Peak Elev= 37.51' @ 12.24 hrs Surf.Area= 3,785 sf Storage= 8,998 cf Plug -Flow detention time= 68.3 min calculated for 0.242 of (62% of inflow Center -of -Mass det. time= 39.8 min ( 782.5 - 742.7 ) # Invert Avail.Stora e Storage Description 1 34.50' 10,830 cf Custom Stage Data (Prismatic) Listed below Elevation Surf.Area Inc.Store Cum.Store (feet) (sq-ft) (cubic -feet) (cubic -feet) . 34.50 2,193 0 0 35.00 2,436 1,157 1,157 36.00 2,955 2,696 3,853 37.00 3,450 3,203 7,055 38.00 4,100 3,775 10,830 # Routing Invert Outlet Devices 1 Primary 34.50' 15.0" x 313.0' long Culvert RCP, square edge headwall, Ke= 0.500 Outlet Invert= 33.42' S= 0.0035 T n= 0.013 Cc= 0.900 2 Device 1 34.50' 1.0" Vert. Orifice/Grate C= 0.600 3 Device 1 36.60' 1.00' x 0.30' Vert. OrificelGrate C= 0.600 4 Device 1 37.40' 16.0' long x 1.0' high Sharp -Crested Rectangular Weir 2 End Contraction(s) Primary OutFlow Max=3.36 cfs @ 12.24 hrs HW=37.51' (Free Discharge) L1=Culvert (Passes 3.36 cfs of 5.60 cfs potential flow) 2-Orifice/Grate (Orifice Controls 0.05 cfs @ 8.3 fps) 3=OrificelGrate (Orifice Controls 1.26 cfs @ 4.2 fps) =Sharp -Crested Rectangular Weir (Weir Controls 2.06 cfs @ 1.1 fps) 31 or �j 04024Promenade Type Ill 24-hr 50 Yr. Storm Rainfall=9. 00 " Prepared by Andrew & Kuske Consulting Engineers, Inc. Page 45 HydroCAD® 7.01 sln 000479 © 1986-2004 Applied Microcomputer Systems 4/21/2004 Pond 4P: C.O.W. Existing Pond Evaluation Hydrograph 10 Inflow --_--...-.. _---------- ............ -� 7.88c1s 1z,o7nrs �----.,._....__..�.�._,�,.,..,...,.,- :Primary 8- Inflow Are6=0.860 ac 7_• Peak Elev=37.51' ----------------- ----- 8 - --------------------- -- - .---.. --- Storade=8,998 cf w 5 rA` o..... ,.._.�. ._�.,..,.... ,:, .....,. .....E .._..... ................ ...... .,.,--- .,------------------ .,..-- 3 2 4 ; _........... --..... ...._ 3.37 GIs 12.24 hrsI ------ _-.--._......._-.................... ............-...._....-..-__... ..._-__ i 11 12 13 14 15 Time ihours) .ri .d ion 1 _'7) P--2 1-3 �,I MIA 1-5 Outlet Project Title: NORTH MARKET PROMENADE STORMORAIN PIPE CALCULATIONQ Project Engineer: JOHN A. KUSKE, III, P.E. cAhaestadl-gym-knromste.stm StormCAD v1.0 0 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA (203) 755-1666 Page 1 of 1 Pipe, pe, C'0qC-&"' DOT Report '® efcooL 3 0� � Pipe -Node- Upstream Downstream Inlet Area (acres) Inlet CA (acres) Total CA (acres) -Ground- Upstream Downstream (ft) -HGL- Upstream Downstream 01) -Slope- Energy Constructed (fuft) -Section- Discharge Capacity (cfs) -Section- Shape Size Length (ft) Average Velocity (ftls) Description P-7 !-8 0.23 0.20 0.20 37.90 36.12 0.000485 1.46 Circular 82.00 1.24 -9 37.70 36-09 0.002927 3.49 15 inch P-8 1-9 0.24 0.21 0.41 37.70 36.09 0.002025 2.91 Circular 60.00 2.37 J-1 39.00 35.96 0.005000 4.57 15 inch P-1 1-1 0.46 0.40 0.40 38.50 38.17 0.002001 2.89 Circular 72.00 2.35 1-2 38.90 38.03 0.002083 2.95 15 inch P-2 1-2 0.09 0.09 0.48 38.90 38.03 0.002880 3A7 Circular 95.00 2,82 1-3 39,00 37.76 0.002526 3.25 15 inch P-3 1-3 0.11 0A0 0.59 39.00 37.76 0.004141 4.16 Circular 25.00 3,39 1-4 39.00 37.65 0.002800 3.42 15 inch P-4 1-4 0.12 0.10 0.68 39.00 37.65 0.005571 4.82 Circular 135.00 3,93 1-5 38.60 36.90 0.003481 3.81 15 inch P-5 1-5 0.11 0.10 0.78 38.60 36.90 0.007021 5.41 Circular 60.00 4.41 1-6 39.00 36.48 0.004167 4.17 15 inch P-6 1-6 0.43 0.41 1.19 39.00 36.48 0.016130 8.20 Circular 32.00 6.69 J-1 39.00 35.96 0.003750 3.96 15 inch P-9 J-1 N!A NIA 1.60 39.00 35.96 0.028940 11.02 Circular 10,00 9.03 Outlet 38.50 35.641 0.0060001 5.00 15 inch 7�7Gc.�JL , Lam vi?'�r'Z C� ,it--� o 4,-7L,L0-' T, Project Title: NORTH MARKET PROMENADE STORMDRAIN PIP= rrni r,i n,ATIONS Project Engineer: JOHN A. KUSKE, III, P.E. c:lhaestadXstmc%promste.stm StormCAD v1.0 C Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA (203) 755-1666 Page 1 of 1 .:. FW r' :x s/ s1 Pipe -Node- Upstream Downstream Inlet Area (acres) Inlet CA (acres) Total CA (acres) -Ground- Upstream Downstream (ft) -HGL- Upstream Downstream (ft) -Slope- Energy Constructed (fUft) -Section- Discharge Capacity (cfs) -Section- Shape Size Length (ft) Average Velocity (fus) Description P-7 1-8 0.23 0.20 0.20 37.90 36.26 0.000645 1.65 Circular 82.00 1.35 1-9 37.70 36.21 0.002927 3.49 15 inch P-8 1-9 0.24 0.21 0.41 37.70 36.21 0.002589 3.29 Circular 60.00 2.68 J-1 39,00 36.06 0.005000 4.57 15 inch P-1 1-1 0.46 0.40 0.40 38.50 38.89 0.002543 3.26 Circular 72.00 2.65 1-2 38.90 38.71 0.002083 2.95 15 inch P-2 1-2 0.09 0.09 0.48 36.90 38.71 0.003673 3.91 Circular 95.00 3.19 0 39.00 38.36 0.002526 3.25 15 inch P-3 1-3 0A 1 0.10 0.59 39.00 38,36 0.005303 4.70 Circular 25.00 3.83 1-4 39.00 38,23 0.002800 3,42 15 inch P-4 1-4 0.12 0.10 0.68 39.00 38.23 0.007141 5.46 Circular 135,00 4.45 1-5 38.60 37.26 0.003481 3.81 15 inch P-5 1-5 0.11 0.10 0.78 38.60 37.26 0.009039 6.14 Circular 60.00 5.00 1-6 39.00 36.72 0.004167 4,17 15 inch P-6 1-6 0.43 0.41 1.19 39.00 36.72 0.020806 9.32 Circular 32.00 7.59 J-1 39.00 36.06 0.003750 3.96 15 inch P-9 J-1 N/A N/A 1.60 39.00 36.06 0.037484 12.52 Circular 10.00 10.23 Outlet I 1 138,501 35.66 0.0060001 5.00115 inch Project Title: NORTH MARKET PROMENADE STORMDRAIN PIPE CALCULATIONS Project Engineer: JOHN A. KUSKE, III, P.E. G:1haPq+ar{Nctmr.5nrnmste.stm StormCAD v1.0 aestad Methods, Inc. 37 Brookside Road vvaiciu..y, �} 06708 USA (203) 755-1666 Page 1 of 1 rpad G- DOT Report 35 Ot Pipe -Node- Upstream Downstream Inlet Area (acres) Inlet CA (acres) Total CA (acres) -Ground- Upstream Downstream (ft) -HGL- Upstream Downstream (ft) -Siope- Energy Constructed (ftlft) -Section- Discharge Capacity (cfs) -Section- Shape Size Length (ft) Average Velocity (fUs) Description P-7 1-8 0.23 0.20 0.201 37.90 36.38 0.000770 1.79 Circular 82.00 1.46 1-9 37.70 36.32 0M2927 3.49 15 inch P-8 1-9 0.24 0.21 0.41 37.70 36.32 0.003083 3.59 Circular 60.00 2.92 J-1 39.00 36.13 0.005000 4.57 15 inch P-1 1-1 0.46 0.40 0.40 38.50 39.51 0.008535 3.55 Circular 72.00 2.89 1-2 38,90 38.90 0.002083 2.95 15 inch P-2 1-2 0.09 0.09 0.48 38,90 39.30 0.004362 4.27 Circular 95.00 3.48 1-3 39.00 38.88 0.002526 3,25 15 inch P-3 1-3 0.11 0.10 0.59 39.00 38.88 0.006314 5.13 Circular 25.00 4.18 1-4 39.00 38.73 0.002800 3.42 15 inch P-4 1-4 0.12 0.10 0.68 39.00 38.73 0.008508 5,96 Circular 135,00 4.86 1-5 38.60 37.58 0.003481 3.81 15 inch P-5 1-5 0.11 0.10 0.78 38,60 37.58 0.010801 6,71 Circular 60.00 5.47 1-6 39.00 36.93 0.004167 4.17 15 inch P-6 1-6 0.43 0.41 1.19 39.00 36.93 0.024890 10.19 Circular 32.00 8.30 J-1 39.00 36.13 0.003750 3.96 15 inch P-9 J-1 NIA NIA 1.60 39.00 36.13 0.044905 13.69 Circular 10.00 11.18 Outlet 138.50 35.67 0.006000 5,00 15 inch o100c: 34-.'� Project Title: NORTH MARKET PROMENADE STORMDRAIN PiPG rrni r I u ATIONS Project Engineer: JOHN A. KUSKE, III, P.E. c.lhaestadlstmclpromste.stm StormCAD v1.0 0 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA (203) 755-1666 Page 1 of 1 13 Me,- 6d T OGGs� 7� PiPC� C�}-GC vG�j7 0�.1 Outlet P-2 1-2 Project Title: NORTH MARKET PROMENADE NC DOT STORMDRAIN PIPE CALCULATIONS Project Engineer: JOHN A. KUSKE, III, P.E. c:lhaestadtstmclprmdot.stm SITEWORKS DESIGN GROUP StormCAD v1.0 04/23/04 08:44:28 PM 0 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA (203) 755-1666 Page 1 of 1 /vim vc. r DOT Report /'::' LjEiNt_ Pipe -Node- Inlet Inlet Total -Ground- -HGL- -Slope- -Section- -Section- Length Average Description Upstream Area CA CA Upstream Upstream Energy Discharge Shape (ft) Velocity Downstream (acres) (acres) (acres) Downstream Downstream Constructed Capacity Size (ft/s) (ft) (ft) (fUft) (cfs) P-1 1-1 0.08 0.08 0.08 40.70 35.34 0.000242 0.55 Circular 50,00 0.71 1-2 40.40 35.33 0.003000 1.95 12 inch P-2 1-2 0,01 0.01 0.09 40.40 35.33 0.000003 0.60 Circular 10.00 0.15 Outlet 40.60 35.33 0,005000 29.00 30 inch -F /9 7S45�Ctu/l���/ Project Title: NORTH MARKET PROMENADE NC DOT STORMDRAIN PIPE CALCULATIONS Project Engineer: JOHN A. KUSKE, Ill, P.E. c:lhaestad%sImc\prmdot.stm SITEWORKS DESIGN GROUP StormCAD v1.0 04/23/04 08;43:12 PM cis Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA (203) 755-1666 Page 1 of 1 /VG AVo 7- F'19r-'.4_E CAL DOT Report �! Pipe -Node- Inlet Inlet Total -Ground- -HGL- -Slope- -Section- -Section- Length Average escription Upstream Area CA CA Upstream Upstream Energy Discharge Shape (ft) velocity Downstream (acres) (acres) (acres) Downstream Downstream Constructed Capacity Size (fVs) (ft) (ft) (Rift) (cfs) P-1 1-1 0.08 0.08 0.08 40.70 35.35 0.000307 0.62 Circular 50.00 0.79 -2 40.40 35.33 0.003000 1.95 12 inch P-2 1-2 0.01 0.01 0.09 40.40 35.33 0.000003 0.68 Circular 10.00 0.18 Outlet 40.60 35.33 0.005000 29.00 30 inch Project Title: NORTH MARKET PROMENADE NC DOT STORMDRAIN PIPE CALCULATIONS Project Engineer: JOHN A. KUSKE, III, P.E. c�\haestadlstmc\prmdot.stm SITEWORKS DESIGN GROUP Storm CAD v1.0 04/23/04 0BA5:06 PM C Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA (203) 755-1666 Page 1 of 1 NG 0 o T .�io� C�� DOT Report Sp y� Pipe -Node- Inlet Inlet Total -Ground- -HGL- -Slope- -Section- -Section- Length Average Des ription Upstream Area CA CA Upstream Upstream Energy Discharge Shape (ft) Velocity Downstream (acres) (acres) (acres) Downstream Downstream Constructed Capacity Size (ftls) (ft) (ft) (f ift) (cfs) P-1 1-1 0.08 0.08 0,08 40.70 35.35 0.000364 0.68 Circular 50.00 0.87 1-2 40.40 35.33 0.003000 1.95 12 inch P-2 1-2 0.01 0.01 0.09 40.40 35.33 0.000004 0.75 Circular 10,00 0.19 Outlet 40.60 35.33 0.005000 29.00 30 inch Project Title: NORTH MARKET PROMENADE NC DOT STORMDRAIN PIPE CALCULATIONS Project Engineer: JOHN A. KUSKE, III, P,E. cahaestadlstmclprmdot.stm SITEWORKS DESIGN GROUP StormCAD v1.0 04l23l04 08:45:59 PM 0 Haestad Methods, Inc. 37 Brookside Road Waterbury, CT 06708 USA (203) 755-1666 Page i of 1 Date Design Andrew and Kuske Sheet 1�i 902 Market St. CONSULTING ENGINEERS, INC. Wilmington, N.C. 28401 Of Check Job For Nam. ,.yyy� Job No. G�9L�c��/TS"7vlrri' � CAI-+C� �.G �rio.� j _ Co.�i7n-ate � �C/�7��a n%�/d r�z' G ..�• s�-l7 ©r.✓../� 90 7>L-0L AD lrf�c .� �c-s�C c��--�'T� •��••_//J rrJLf =% .�"�i�.f�h.�� .r�/.�3/��'ta�-I 0 6 = is"/ / ♦, z3' / .7 G/, 0.3 A /--9Co.--7 C: j -7 s-o X /o IN •b = I1. t_ I 0 ESTIMATION OF STONE SIZE AND DIMENSIONS FOR CULVERT APRONS 2 I ! t ! I l I 1 ! r 1 1 �, 1 1 20 'e , 1 1 1 ! 1 I I I 1 1 t r I 15 1 is I 1 - t 1 I 110 I 1 r I 1 4 I 1 2 1 1 I 3 I I I I I I 1 I I ! 1 0 s s 5 10 15 20 25 F T. sltp I> trtl4nals flow vsloclly Va of culverl or paved channel outlel. slap 2> for pipe culvarls ()A Is dlamelar. roe pips arch, orch and box culverls and paved channel outtals, 0a Aa. where A a — cross sectional w•o of Aoa of outlet. roe mulllpls culverts, use Oa + 1.23 r 0 a of ,Ingle culvert. step 3> roe apron grodei of to% ar sleeper. use recommendollons for neyl hlghar tons (tones I thru S) Pi LENGT11 OF APRON I,, i. p APRON MATERIAL TO PROTECT 10 PRrvull N CVL,VEAf SCOUR HOLE EI L2 t Slona r>f11ng (rive) 3 r 0 a 4 a D a 2 Slone r1rnq (09M) 3 a D 4 6. 0 0 3 Slane rYling (uedlum) 4 a 0 0 8■ D o 4 Slone rifling (lteovy) 4■ 0 o C e D a S Stone ruing (ISeovy) S■ D o to r 0 a 6 Slone r,llnq (l(savy) 6 s 0 a 12 , 0 0 7 Special study required (energy dletpalwe, sl7llnq bosh or loeger *ion* silo.) SOURCE BANKS AND CffANNE:t_ LINING f IIOCEE mnES, N Y 001L, 01VIS10N OF DFSIGII AND CONSTRUCTION, I971 (INORRIS, KUSKE & TUNSTALL CONSULTING ENGINEERS, INC. J. Phillip Norris, RE, John A. Kuske, III, P.E. John S. Tunstall, P.E. J.A. Kuske, P.E. James T. Pyrtle, P.E. C. Lawrence Sneeden, Jr., P.E. 902 Market Street • Wilmington, NC 28401-4733 a Phone (910) 343-9653 * Fax (910) 343-9604 www.andrewandkuske.com • office@andrewandkuske.com Ir S w 7 �'(" 03 LETTER OF TRANSMITTAL To: Laurie Munn Date: May 27, 2004 __]Job No. 04024 NC DENR subject: North Market Promenade 5500 Market Street Wilmington, NC WE ARE SENDING YOU VIA HAND DELIVER JFAX ® ATTACHED ❑ UNDER SEPARATE COVER ❑ SHOP DRAWINGS ® PRINTS ❑ TRACINGS ❑ SPECIFICATIONS ❑ DISKS ❑ COPY OF LETTER ❑ . TRANSMITTAL:'= NUMBER: -OF PAGES: 'INCLUDING THISTRANSMITTAL - Call 910-343 9653 if you have any difficulty.: receiving"this` message COPIES DATE NO. DESCRIPTION 1 Revised Pg. 1 of State Stormwater Wet Detention Basin Supplement (SWU-102) 1 05-25-04 Stormwater Pond Volume 2 05-27-04 C1 Existing Site Conditions, Demolition, Erosion Control & Tree Removal Plan 2 05-27-04 C2 Grading, Drainage, Erosion Control & Stormwater Management Plan 2 05-27-04 C3 Utility Layout Plan 2 05-27-04 C4 Site Layout Plan 2 05-27-04 C5 Notes and Details 2 05-27-04 C6 Utility Notes and Details SP? L-7 I PPIA AVP - �k P1 I ❑ AS REQUESTED ❑ FOR YOUR USE ❑ FOR REVIEW AND COMMENT ❑ F004PROV ❑ FOR BIDS DUE ❑ Y RINTS LOANED TO US REMARKS: vas, Per your comment letter of May 5, 2004. If you need any additional information, please let us know. Thank you. CC: SIGNED John A. Kuske, ill, P.E., / asn CONFIDENTIAL AND PRIVILEGED: Information contained in this document is privileged and confidential, intended for the sole use of the addressee. If you are not the addressee or the person responsible for delivering it to the addressee you are hereby notified that any dissemination, distribution or copying of this document is strictly prohibited. If you have received this document in error please immediately notify the sender and return to the address above. OF \,N A Tf 9 Michael F. Easley, Governor Q WiNam G. Ross Jr., Secretary North Carolina Department of En,.*onment and Natural Resources .Alan W. Klimek, P.E.,Director Division of Water Quality Coleen H. Sullins, Deputy Director Division of Water Quality May 5, 2004 itMr. Blaine East Pointe @ North Market. LLC 206 Sher -wood Forest Place Can-, NC 27519 Subject: REQUEST FOR ADDITIONAL IN'FORNMATION Stormwater Project No. S«'S 960315 Modification North Market Promenade Nei~;• Hanover Count, Dear \Mr. East: The Wiimington Regional Office received a Stormwater Management Permit Application for North Market Promenade on April 2S, 2004. A preliminary review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: J17. 1. Please pro%-ide dimensions for the building footprint. 4/ 2. Please show the inlet pipe going into the pond. 3. Please specify the wetland species to be planted on the 6:1 shelf. ✓ 4. Please lower the forebay elevation to 31.50 so that the required 3-foot depth is met. 5. Piease provide the volume of the entire pond at the permanent pool elevation and the volume of the forebay. Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to May 12, 2004, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items. including the application fee. If you need additional time to submit the information, please mail or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter. The request must indicate the date by which you expect to submit the required information. The Division is allowed 90 days from the receipt of a completed application to issue the permit. The construction of any impen�lous surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a .-iolation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-21 5.6A. .w/� N. C. Division of Water Quality 127 Cardinal Drive Extension (910) 395-3900 Customer Service O'�ll.1 Wilmington Regional Oft"i e Wilmington, NC 28405 (910) 350-2004 Fax 1 800 623-7748 NMENR Mr. Blaine East Pat,e 2 Nlav 2004 Please reference the State assigned project number on all correspondence. Any original documents that need to be revised have been sent to the engineer or agent. All original documents must be returned or neiv originals must be provided. Copies are not acceptable. If you have any questions concerning this matter please feel free to call me at (910) 395-3900. Sincerely, t Laurie Munn En%gronmental Engineer RSSlasm S,\WQS\STORMN�IARkDDLNi TF01?0041960315MOD.may04.doc cc: Laurie Munn John A. Kuske,111, P.E. State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Michael F. Easley, Governor William G. Ross Jr., Secretary Date: 4T:5 /O To: CO: FAX #: 3y3 - (0 0 q REMARKS: FAX COVER SHEET No. Of Pages: -3 _ From: u-tu- Mt _n h CO: O'Y/o dL FAX#: 410-350-2004 127 Cardinal Drive Extension, Wilmington, Y.C. 28405-3845 Telephone (910) 395-3900 Fax (910) 350-2004 An Equal Opporlunity Affirmative Action Employer MEET 1 ` i l e (� Ila F 1 r t77;Itttij }, r}4 {,n , .� + i ++•F i'4 J U e d�p�U•.'4v'"i,�7,uls� f�, rl�i�:i4�,►,�^�1:!sl)Qb� 1@�y�., yu�+J� 14� ` F�'+' � r • �. „�.� y '�� i � ,y 7�i�i�h. ,.�; k,_ .F 4 _ _ _ .,pl k� .1tF�,1 aI11�i/w +Jjl lip I��.1(ii��i.likw • �Li,f.t r 127 Cardlital Drive Extgisints, Wllmingten, N.C. 2POs5 3845 Telephonp (910) 3"5 ;00o .Zpp- An Equal uPPOMUnity AfnrmalivC ActFOlt �mplOycr Fax (910) 3arpq A ' Entity Names Page 1 of 1 • North Carolina Elaine F. Marshall DEPARTMENTOF THE Secretary SECRETARY OF STATE Corporations *Corporations Home "Important Notice °Corporate Forms/Fees °Corporations FAQ *Tobacco Manufacturers "Verify Certification *Online Annual Reports Links QSecretary Of State Home *Business License `Register for E-Procuremer •Dept. of Revenue Legislation e1999 Senate Bills 02001 Bill Summaries OAnnual Reports 1997 *Corporations 1997 °Other Legislation Search *By Corporate Name *For New Corporation *By Registered Agent Online Orders *Start An Order •New Payment Procedures PO Box 29622 Raleigh, NC 27626-0622 {919}607-2000 Date: 5/5/2004 Click here to: View Document Filings 1 Print a pre -populated Annual Report Form I File an Annual Report I Corporation Names Name Name Type NC Pointe at North Legal Market, LLC Limited Liability Company Information SOSI D: 0706498 Status: Current -Active Date Formed: 1/13/2004 Citizenship: Domestic State of Inc.: NC Duration: Perpetual Registered Agent Agent Name: East, Blaine Registered Office Address: 206 Sherwood Forest Place Apex NC 27502 Registered Mailing % Landcore, L.L.C. Address: 206 Sherwood Forest Place Apex NC 27502 Principal Office Address: 1111 Kane Concourse, Ste 401 Bay Harbor Islands FL 33154 Principal Mailing Address: 1111 Kane Concourse, Ste 401 Bay Harbor Islands FL 33154 For questions or comments about the North Carolina Secretary of State's web site, please send e-mail to Webmaster. For questions or comments concerning the Corporations Division, please send e-mail to Corporations Administrator Click here for help downloading forms. http://www.secretary.state.ne.us/Corporations/soskb/Corp.asp?6176947 5/5/2004 Andrew & Kuske CONSULTING ENGINEERS, INC. 902 Market Street V0Imington, NC 28401-4733 910/343-9653 910/343-9604 Fax www.andrewandkuske.com April 27, 2004 Ms. Laurie Munn, Environmental Engineer NC DENR Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405-3845 John R. Andrew, P.E. John S. Tunstall, P.E. John A. Kuske, III, P.E. James T. Pyrtle, P.E. J. Phillip Norris, P.E. Neal W. Andrew, RE, J.A. Kuske, P.E. of Counsel C. Lawrence Sneeden, Jr., P.E. Re: State Stormwater Express Permit Submittal for an Existing Wet Detention Basin North Market Promenade 5500 Market Street,_ Wilmington, NC L T A & K Project No. 04024 ApR 2 8 )004 Dear Ms. Munn: Enclosed are two (2) sets of plans for the subject project, one (1) drainage area plain`, one (1) set of calculations, the original Division of Water Quality Stormwater Management Permit application, the original SWU-102 supplement form, one (1) copy of State Stormwater Permit No. SW8 960315 Modification, one (1) copy of the stormwater narrative and a $4,000.00 check for the express permit review fee. Please review this information for approval on May 5, 2004 as scheduled. Please contact us with any questions or comments you may have. Thank you for your assistance on this project. Sincerely, ANDREW & KUSKE CONSULTING ENGINEERS, INC. Joh A. Kuske, III, P.E. JAKIII/asn 04024 04-27-04-s-sw-Itr Enclosures CC' Scott Bradley / Bradley Barnes Construction Company Misty Watkins / City of Wilmington NORRIS, KUSKE, & TUNSTALL J• Phillip Norris, P.E. John A. Kuske, III, P.E. John S. Tunstall, P.E. J.A. Kuske, P.E. CONSULTING ENGINEERS, INC. JamesT. Pyrtle, P.E. C. Lawrence Sneeden, Jr., P.E. 902 Market Street • Wilmington, NC 28401-4733 • Phone (910) 343-9653 • Fax (910) 343-9604 www.andrewandkuske.com . office@andrewandkuske.com LETTER OF TRANSMITTAL To: Cameron Weaver Date: April 28, 2004 .lob No. 04024 NC DENR Express Permitting Dept. subject: North Market Promenade 5500 Market Street Wilmington, NC rE ARE SENDING YOU V!A HAND DELIVER ATTACHED ❑ UNDER SEPARATE COVER ❑ SHOP DRAWINGS ❑ PRINTS ❑ TRACINGS ❑ SPECIFICATIONS ❑ DISKS ❑ COPY OF LETTER ❑ FAX TRANSMITTAL; ,_NUMBER- OF PAGES- =`INCLUDING THIS TRANSMITTAL = Calf 9� 0-343=9653 `if .you have - any difficulty` receiNong this_message. _;- COPIES DATE NO. DESCRIPTION 1 04-04 Copy of Stormwater System & Erosion Control Narrative OWL V rFORAEQUESTED ❑ FOR REVIEW AND COMMENT ❑ FOR APPROVAL YOUR USE ❑ FOR BIDS DUE ❑ YOUR PRINTS LOANED TO US REMARKS: This project has been scheduled by Laurie Munn for review on May 5, 2004. If you have any questions, please feel free to call. Thank you. CC: SIGNED John A. Kuske, III, P.E., 1 asn CONFIDENTIAL AND PRIVILEGED: Information contained in this document is privileged and confidential, intended for the sole use of the addressee. If you are not the addressee or the person responsible for delivering it to the addressee you are hereby notified that any dissemination, distribution or copying of this document is strictly prohibited. If you have received this document in error please immediately notify the sender and return to the address above. STORMWATER SYSTEM & EROSION CONTROL NARRATIVE NORTH MARKET PROMENADE 5500 MARKET STREET WILMINGTON, NORTH CAROLINA For Pointe @ North Market, LLC 206 Sherwood Forest Place Cary, NC 27519 (919) 362-1700 616191 off April 2004 Prepared by: ANDREW & KUSKE CONSULTING ENGINEERS, INC. 902 Market Street Wilmington, North Carolina 28401 (910) 343-9653 (910) 343-9604 (Fax) E-mail: office@ and rewandkuske.com A & K Project No. 04024 NARRATIVE PROJECT DESCRIPTION; The existing site is a 1.92 acre developed site within the Wilmington City limits, in New Hanover County, North Carolina. The existing site is being redeveloped to include a new mixed use building with office, retail and restaurant space. The existing site has existing access to Market Street (US Hwy. 17) and Old Eastwood Road. SITE DESCRIPTION AND INFORMATION: As stated above, the existing site is developed and will be redeveloped to include a new mixed use building with office, retail and restaurant space. Existing asphalt parking and access currently exist on the site. An existing permitted stormwater pond also currently exists on the site. Minor parking lot and access modifications will be required to accommodate the new building. The building that was on the site was demolished several years ago. The existing site is currently permitted under New Hanover County Grading Permit No, GP 26-96 Revision and State Stormwater Permit No. SW8 960315 Modification. Copies of the above permits are included with the permit submittals. The site is now within the Wilmington City limits. Therefore, the new impervious area will be subject to the City of Wilmington Stormwater Ordinance. The stormwater pond outlet structure will be modified to meet the City of Wilmington Stormwater Ordinance. Additional stormwater pond modifications are proposed to meet the State Stormwater regulations as described below. As stated above, impervious area on the site consist of existing asphalt parking and access and new impervious area defined as follows. New impervious area is the new building and existing asphalt pavement and concrete which is being removed and replaced. As stated above, the new impervious area is subject to the City of Wilmington Stormwater Ordinance. Overall, there is a net decrease in total impervious area listed in State Stormwater Permit No. SW8 960315 Modification from 65,550 SF to 63,400 SF. See the site data table in the calculations and on Sheet C4 of the plans for a detailed breakdown of impervious areas. Grades on the existing site vary as shown on the plans. Approximately 2.86 acres is included in the disturbed area 1 construction limits. A portion of the disturbed area / construction limits include a new right turn lane and new sidewalks within the NC DOT right of way along Market Street (US Hwy. 17). A portion of the disturbed area I construction limits also include the existing driveway and new sidewalks within the City right of way along Old Eastwood Road. There are no protected or significant trees on the existing site. EROSION CONTROL MEASURES: The attached plans and specifications give the requirements for erosion control measures. Silt fence shall be installed on the site prior to grading as shown on the attached plans. The existing stormwater pond will be used as a silt basin during construction and restored to the proposed design contours prior to completion of construction. Erosion control measures shall be installed around the drop inlets as shown on the plans to trap silt during construction. Inspect the erosion control around the inlets after each rain to make repairs as needed. Remove sediment as necessary to provide adequate storage volume for subsequent rains. When the contributing drainage area has been adequately stabilized, remove all materials and any unsuitable soil and either salvage or dispose of it properly. Bring the disturbed area to proper grade, then smooth and compact it. Appropriately stabilize all bare areas around the drop inlets. A gravel construction entrance will be provided as noted on the plans. Maintain the gravel construction entrance in a condition to prevent mud or sediment from leaving the site. STORMWATER MANAGEMENT MEASURES: The project site is located in the Wilmington City limits in New Hanover County, North Carolina. Land disturbing on the site will exceed one acre, which requires the site to comply with the State Stormwater Regulations. In addition, a portion of the site will also have to comply with the City of Wilmington Stormwater Ordinance. The existing stormwater pond will be restored and modified to meet both the State and City of Wilmington design standards. This narrative will focus on the aspects of the state design criteria. The existing stormwater detention pond is designed to achieve 90% TSS removal. Critical design elevations are detailed on the plans and in the calculations. The required storage volume will be released within the 2-5 day draw down period as shown in the calculations. A forebay is provided at the head of the stormwater pond. When the stormwater pond was originally approved, the forebay was not required to handle 20% of the total pond volume. A 10' vegetative shelf was also not required when the stormwater pond was originally approved under State Stormwater Permit No. SW8 960315 or SW8 960315 Modification. As stated above, the stormwater pond outlet structure will be modified to meet the City of Wilmington Stormwater Ordinance. Other stormwater pond modifications will include re- establishing the existing approved forebay and re-establishing the approved stormwater pond depth and increasing the stormwater pond depth by 0.50' to meet the State surface area requirement at normal pool. All stormwater runoff from impervious areas will be directed to the stormwater pond. CONSTRUCTION SEQUENCE: The contractor will install the gravel construction entrance and silt fence prior to beginning any grading operations. The existing stormwater pond will be used as silt basins during initial grading phase. The stormwater pond will then be fine graded and restored to the proposed contours shown on the plans and the outlet structures and piping will be installed with riprap protection. Disturbed areas will be landscaped or seeded within 15 days of disturbance. MAINTENANCE PLAN 1. All erosion and sediment control practices will be checked for stability and operation following every runoff -producing rainfall but in no case less than once every week. Any needed repairs will be made immediately to maintain all practices as designed. 2. Install erosion control measures before beginning construction or as soon thereafter as possible. All erosion and sediment control practices will be checked for stability and operation following every runoff -producing rainfall but in no case less than once every week. Any needed repairs will be made immediately to maintain all practices as designed. 3. Maintain the gravel construction entrances in a condition to prevent mud or sediment from leaving the construction site. The contractor shall inspect the construction entrances on a daily basis. This will require periodic top dressing with additional No. 4 stone. Any objectionable materials spilled, washed, or tracked onto public roadways shall be removed immediately. 4. Install erosion control measures around the drop inlets as shown on the plans to trap silt during construction. Inspect the erosion control around the inlets after each rain and make repairs immediately. Remove sediment when it becomes 0.50 deep to provide adequate storage volume for subsequent rains. When the contributing drainage area has been adequately stabilized, remove all materials and any unstable soil and either salvage or dispose of it properly. Bring the disturbed area to proper grade and appropriately stabilize all bare areas around the drop inlets. 5. Sediment will be removed from behind the silt fence when it becomes 0.5 feet deep at the fence. The sediment fence will be repaired as necessary to maintain a barrier. 6. No cut or fill slopes shall exceed a side slope of 1 vertical to 3 horizontal unless otherwise specified on the plan. All slopes shall be seeded and stabilized within 15 days. 7. The stormwater ponds will act as sediment basins and will be cleaned out when the level of sediment reaches 2.0 ft below the top of the riser. Gravel will be cleaned or replaced when the sediment pool no longer drains properly. 8. No cut or fill slopes shall exceed a side slope of 1 vertical to 3 horizontal unless otherwise specified on the plan. All slopes shall be seeded and stabilized within 15 days. 9. All disturbed areas shall be seeded within 15 days of disturbance. All seeded areas will be fertilized, reseeded as necessary and mulched according to specifications in the vegetative plan to maintain a vigorous, dense vegetative cover. 10. More stringent measures shall be used to halt erosion if those shown on this plan are not effective. 11. All erosion shall be controlled including side slopes before the project is completed. 12. Remove temporary measures upon completion of project. All permanent measures will be well established before project closeout. SECTION 02920 SOIL EROSION AND SEDIMENTATION CONTROL 1. GENERAL 1.1 Contractor shall take every reasonable precaution throughout construction to prevent the erosion of soil and the sedimentation of streams, lakes, reservoirs, other water impoundments, ground surfaces, or other property as required by State and Local regulations. 1.2 The Contractor shall install all required silt fences, and construction entrances at the initiation of work, and have these measures reviewed and approved by the local permit authority prior to clearing and grading operations. 1.3 The Contractor shall, within 15 days of suspension or completion of land disturbing activities, provide permanent protective covering for disturbed areas. Temporary and permanent erosion control measures shall be coordinated to assure economical, effective, and continuous erosion and siltation control throughout the construction and post -construction period. Use the specified seed for both temporary and permanent seeding. 2. PRODUCTS 2.1 Asphalt for anchoring mulch shall be Type SS-1 Emulsion. 2.2 Fertilizer shall be 10-10-10 grade or equivalent. 2.3 Lime shall be dolomitic agricultural ground limestone containing not less than 10 percent magnesium oxide. 2.4 Mulch shall be small grain straw, hay, wood chips, asphalt emulsion, jute or other suitable material free of undesirable weed seed. 2.5 Phosphate shall be 20 percent superphosphate or equivalent. 2.6 Seed shall be 20% carpet grass, 24% Bermuda, 20% turf Fescue, 10% Creeping Red Fescue, and 24% Annual Rye grain. Bermuda seed shall be hulled for warm weather planting and unhulled for cool weather planting. Purity of seed shall be a minimum of 98 percent and germination shall be a minimum of 85 percent. 2.7 Silt fence shall consist of NCDOT Class A fabric supported by wood or metal posts spaced not more than 6 feet on center. The bottom of the fabric shall be buried a minimum of 6 inches. 2.8 Gravel for check dams shall be #57 washed stone. 2.9 Aggregate for construction entrance shall be #4 washed stone. 2.10 Stone rip rap for check dams and erosion control shall be NCDOT Class A or B as shown. 3. EXECUTION 3.1 General: Take every practicable measure during construction or suspension to work to minimize erosion and siltation. Measures should include good construction practices, temporary physical barriers to sediment travel, settling basins for new ditches, and establishment of vegetative cover. 3.2 Construction Practices 3.2.1 Avoid dumping soil or sediment into any wetland or watercourse. 3.2.2 Maintain an undisturbed vegetative buffer where possible between a natural watercourse and trenching and grading operations. 3.2.3 Avoid equipment crossings of streams, creeks, and ditches where practicable. 3.2.4 Grade all cut, fill and ditch slopes to minimum slope of 3:1, unless otherwise shown or directed. 3.3 Temporary Physical Barriers are required where sedimentation on off site property or excessive erosion is a problem. 3.3.1 Mulch shall be used for temporary stabilization of areas subject to excessive erosion and for protection of seedbeds after planting where required. 1. Apply grain straw and hay at a rate of 75 to 100 pounds per 1000 square feet and wood chips at a rate of 500 pounds per 1000 square feet. Jute and mesh should be installed as per manufacturer's instructions. 2. Asphalt emulsion for slope stabilization should be applied at a rate of 1,000 gallons per acre. Asphalt emulsion used for anchoring straw should be applied at a rate of 150 gallons per ton of straw. 3.3.2 Silt Fences shall be used at the base of slopes to restrict movement of sediment from the site. Clean silt fence of accumulated sediment after each rainfall event or when it exceeds a depth of 0.5 feet above natural grade. 3.3.3 Stone Check Dams, placed at the discharges of creeks, ditches, and swales, shall consist of Class A rip rap at minimum two feet high and three feet thick across the watercourse, with a one - foot thick layer of gravel on upstream side. Remove sediment if accumulated to a depth of 1.0 feet at upstream face. 3.4 Vegetative Cover: Establish and maintain permanent vegetative cover on all unpaved areas disturbed by the work. 3.4.1 Preparation of Seedbed: Areas to be seeded shall be scarified to a depth of 4 inches and until a firm, well pulverized, uniform seedbed is prepared. Lime, phosphorous and fertilizer shall be applied during the scarification process in accordance with the following rates: Lime: 45 pounds per 1000 square feet Phosphorous: 20 pounds per 1000 square feet Fertilizer: 17 pounds per 1000 square feet 3.4.2 Seeding: Disturbed areas shall be seeded with 2 to 3 pounds per 1000 square feet of the specified seed mixture. Seed shall be worked into the bed to a depth of 1/4 inch. Regrade and seed eroded areas immediately 3.4.3 Mulch all areas immediately after seeding. Mulch shall be applied and anchored as specified hereinbefore. Reapply as necessary to retain cover until grass is established. 3.5 Construction Entrance: Provide an aggregate drive, 20 feet wide by 50 feet long by 6 inches thick at each entrance to the site used by construction vehicles, until such time as the permanent roadway is constructed. Remove soil if accumulated to a depth greater than 0.5 inches. 3.6 Maintenance: The Owner and Contractor shall be responsible for maintaining all temporary and permanent erosion control measures. Temporary structures shall be maintained until such time as vegetation is firmly established in the area protected by the structure. Permanent streambank protection and grassed areas shall be maintained until completion of the project. Areas that fail to show a suitable stand of grass or which are damaged by erosion shall be immediately repaired. END OF SECTION 04/29/200.4 THU W 37 FAX 910 343 9604 Norris, Kuske, Tunstall Z601/002 NORRIS, KUSKE, & TUNSTALL J. Phillip Norris, P.E. John A. Kuske, Ili, P.E. CONSULTING ENGINEERS, INC. John S. Tunstall, P.E. J.A. Kuske, P.E. James T. Pyrtle, P.E. C_ Lawrence Sneedt=_n, Jr_, P.E. 902 Market Sht;et a Wilmington, NC 28401-4733 a Phone (910) 343-9653 - Fax (910) 343-9604 www.andrewandkuske.com - ofitoe@andrewandkuske.com LETTER OF TRANSMITTAL To: Laurie Munn Date: April 29, 2004 Job No. 04024 NC DENR - Wilmington Subiect: North Market Promenade 5500 Market Street Wilmington, NC WE ARE SENDING YOU VIA FAX ® ATTACHED ❑ UNDER SEPARATE COVER ❑ SHOP DRAWINGS [I PRINTS ❑ TRACINGS ❑ SPECIFICATIONS ❑ DISKS ❑ COPY OF LETTER ,FAX;: TRANSMITTAL r NUMBER OF:PAGES INCLUDING THIS TRANSIIAITTAL4 * 2` ,. riNr Call ; 910 343-J653 If : y4t1 `.hate; any.r:�dtffict�lty; COPIES DATE NO. DESCRIPTION 1 10-12-96 Copy of State Stormwater Engineer's Certification (Re: SW8 960315 Mod.) ❑ ® AS REQUESTED FOR YOUR USE ❑ FOR REVIEW AND COMMENT ❑ FOR APPROVAL ❑ FOR BIDS DUE ❑ YOUR PRINTS LOANED TO US REMARKS: CC: SIGNED John A. Kuske, 111, P.E., 1 asn CONFIDENTIAL AND PRIVILEGED: Information contained in this document Is privileged and confidential, intendod for the sole use of the addressee. If you are not the addressee or the person responsible for delivering it to the addressee you are hereby notified that any disseminations distribution or copying of this document Is strictly prohibited. If you have received this document in error please immediately nat{fy the sender and return to the address above. 04/29/2004 THU 14:37 FAX 910 343 9604 Norris, Kuske, Tunstall 002/002 -APR.29,269d 10.17AM NCDENR WIRO ._ NO.331 P.1 iiyU�.• 1 A 15AI � srase si* mw6w Mw3APM=t aYft*M 511armwar F - t No. S S 960315 Nor I mr County kA&wes C •uncadon as m daly rt gWred Prgf6miunai Bngl wr 9n the S= Bpi' M rib $.a# 1 wWg b6m ufhodzed to obsor•Yo (p iodi fbc com3mcdoss of the for (Prqect twncr] hereby state that, to tho best of my abilitits, dp cars and as u5r d' ip ft Qhse Mtlaa of the project un=W tioo w ch drat ft conctnz6oa aras Obscrvcd bu7t a►itl: substantial compifaaoe and wu= of tbz approved plm and spadficad=. T Doted devl doW firrnm q mved plans See motion: b 1 E _LHM CARQ� y4'' SEAL �yICLIP HO B �Iffefuu�llW' �% qta fdwpji Hef' /h �'• Po+Gl1vf F State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office James B. Hunt, Jr., Governor - Wayne McDevitt, Secretary Division of Water Quality November 20, 1997 Mr. Donald Mullis, Owner 2212 Pinchurst Place Wilmington, NC 28405 Subject: Permit No. SW8 960315 Modification KIA Service Center High Density Commercial Stormwater Project New Hanover County Dear Mr. Mullis: The Wilmington Regional Office received the modification for the Stormwater Management Permit Application for KIA Service Center on November 14, 1997, with final information on November 20, 4997. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000. We are forwarding Permit No. SW8 960315 Modification dated November 20, 1997, for the construction of KIA Service Center. This permit shall be effective from the date of issuance until November 20, 2007, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the Stormwater management system will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 276t1-7447. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact Linda Lewis, or me at (910) 395-3900. Sincerely, t 1. Rick Shiver, P.G. Acting Regional Water Quality Supervisor RSSlarl: S:1WQSISTORMWATIPERMIT1960315.NOV cc: Phil Norris, P.E. Tony Roberts, New Hanover County Inspections Beth Easley, New Hanover County Engineering Linda Lewis %Wilmington-Regiona_ 1-Office Central Files 127 North Cardinal Dr., Wilmington, North Carolina 28405 Telephone 910-395-3900 FAX 910-350-2004 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper I State Stormwater Management Systems Permit No. $W8 960315 Modification STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, AND NATURAL RESOURCES' DIVISION OF WATER QUALITY - STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Donald Mullis, Owner KIA Service Center New Hanover County FOR THE construction, operation and maintenance of a detention pond in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules ") and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until November 20, 2007 and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described on page 3 of this permit, the Project Data Sheet. The stormwater control has been designed to handle the runoff from 65,550 square feet of impervious area. 3. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 4. The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans, 2 State Stormwater Management Systems Eermit No. SW80 Modification Project Name: Permit Number: DIVISION OF.WATER QUALITY PROJECT DATA -SHEET. - — KIA Service- Center 960315 Modification Location: New Hanover County Applicant: Mr. Donald Mullis, Owner Mailing Address: 2212 Pinehurst Place Wilmington, NC 28405 Application Date: November 14, 1997 Water Body Receiving Stormwater Runoff: Spring Branch Classification of Water Body: "C Sw" If Class SA, chloride sampling results: n/a Pond Depth, feet: 7 Permanent Pool Elevation, FMSL: 34.5 Total Impervious Surfaces, ft2: 65,550 Outparcels, ft2 n/a Future, ft2 3,514 Offsite Area entering Pond, ft2: none, per Engineer Required Surface Area, ft2: 2,776 Provided Surface Area, ft2: 2,917 Required Storage Volume, ft3: 5,265 Provided Storage Volume, ft3: 7,162 Temporary Storage Elevation, FMSL: 36.5 Controlling Orifice: 1 " pipe 3 State Stormwater Management Systems Permit No, SWS 960315 Modification 5. The permittee is responsible for verifying that the proposed built -upon area does not exceed the.allowable built-. - - upon area:= - -6:_.... -The-following items- will -require a modification to the permit: — a. Any revision to the approved plans, regardless of size. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area. e. Further subdivision of the project area. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. In addition, the Director may determine that"other revisions to the project should require a modification to the permit. 7. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. IL SCHEDULE OF COMPLIANCE 1. The permittee will comply with the following schedule for construction and maintenance of the stormwater management system: , a. The stormwater management system shall be constructed in it's entirety, vegetated and operational for it's intended use prior to the construction of any built -upon surface except roads. b. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. C. All connections into the stormwater system from future areasloutparcels shall be made such that short- circuiting of the system does not occur. 2. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of side slopes. d. Immediate repair of eroded areas. e. Maintenance of side slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of outlet structure, orifice device and catch basins and piping. g. Access to the outlet structure must be available at all times. 3. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. 4. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. n State Storm�vater Management Systems' Permit No. SW 260315 dific do 5. Upon completion of construction, prior to issuance of -a Certificate of Occupancy, and prior to operation of this permitted.facility', a certification must be .received from an appropriate designer for the system installed certifying that the :permitted facilityhas been installed in accordance with this permit, the approved plans and specifications, and-otl of supporting documentation: —Any deviations from the approvedplans and specifications must be noted-oii the Certification. 6. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction. 7. Prior to the sale of any portion of the property, an access/maintenance easement to the stormwater facilities shall be granted in favor of the permittee if access to the stormwater facilities will be restricted by the sale of any portion of the property. III. GENERAL CONDITIONS This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143- 215.6C. 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permittee grants DENR Staff permission to enter the property for the purpose of inspecting all components of the permitted stormwater management facility. 6. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. Permit issued this the 20th day of November, 1997. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION \—�)— C C V _ S� t \;' c'- t— ={J c)-- A. Preston Howard, Jr., P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number SWS 960315 Modification 5 - -State Stormwater Management Systems Permit N . SW8 960315Modificati n K1A Service Center Stormwater Permit No. SW8 960315 Modification"'-.' r New HanoveCounty Engineer's Certification I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. Noted deviations from approved plans and specification: Signature Registration Number Date SEAL Z POND MARUENANCE REQ S PAGE 2 TV. Annually (Once a year)-. A. The pond depth will be checked at various points. Sediment removal is required when the depth is reduced to 75 % of the original design depth or T , whichever is greater. Design depth is ', measured vertically from the orifice down to the pond's bottom. Sediment must be removed to at least the original design depth. V. General: a A. Mowing of the side slopes will be accomplished according to the season. Maximum grass height will be 6" . B. Cattails are encouraged along the pond perimeter, however they will be removed when they cover more than 1/2 the surface area of the pond. The best time to cut them is at the end of the growing season, in November. Environmentally sensitive chemicals for use in killing cattails can also be used. Contact your nearest Agricultural Extension Agent. C. The orifice/pump is designed to draw down the pond in 2-5 days. If drawdown is not accomplished in that time, the orifice will be replaced with a Iarger or smaller orifice. Slow drawdown may be attributed to a clogged system. The source of the clogging will be found and eliminated. D. All components of the detention pond system will be kept in good working order. Repair or replacement components will meet the original design specifications as per the approved stoimwater plan. If previously approved components are determined to be ineffective, the component must be redesigned and/or replaced. VI. Special Requirements: 'titi{ LL , hereby aclmowledge that I am the financially (please print or type name clearly) a responsible party for maintenance -of, this detention pond. I will be responsible for the performance of the �1 maintenance -as outlined,above,, as,pa.rt of the Stormwater Management Permit received for this project. k� u�`� Signature: �; Date: Ravised 2125/97 POND MAIN�ANCE.REQL ENMUS_ - - _ :Project Name: Permittee: U~ Address: S �C {' i•�7 c ��C { / ���iGi '% j �" PhoneNo. h ; " /Cc D I. Monthly, or after every runoff producing rainfall event, whichever comes first: A. Inspect the trash rack; remove accumulated debris, repair/replace if it is not functioning. B. Inspect and clear the orifice of any obstructions. If a pump is used as the drawdown mechanism, pump operation will be checked. A log of test runs of the pump will be kept on site and made available to DWQ personnel upon request. C. Inspect the pond side slopes and grassed inlet swales; remove trash, and repair eroded areas before the next rainfall event. D. If the pond is operated with a vegetated filter, the filter will be checked for sediment accumulation, trash accumulation, erosion and proper operation of the flow spreader mechanism. Repairs/cleaning will be done as necessary. II. Quarterly (Four tunes a year): A. Inspect the collection system (ie. catch basins, piping, grassed swales) for proper functioning. Accumulated trash will be cleared from basin grates, basin bottoms, and piping will be checked for obstructions and cleared as required. B. Pond inlet pipes will be checked for undercutting. Riprap or other energy dissipation structures will be replaced, and broken pipes will be repaired. III. Semi-annually (twice a year): A. Accumulated sediment from the bottom of the outlet structure will be removed. B. The forebay depth will be checked at various points. Sediment removal is required when the depth is reduced to 75% of the original forebay design depth of '. C. Grassed swales, including the vegetated filter if applicable, will be reseeded twice a year as necessary. State of North Carolina Departinent of Environlnent Copy and Natural Resources Wilmington Regional Office Jarries B. Hunt, Jr., Governor Wayne McDevitt, Secretary Division of Water Quality Mr. Donald Mullis, Owner 2212 Pinehurst Place Wilmington, NC 28405 Dear Mr. Mullis. November 20, 1997 q'7 3 V?- NORTH CAROLINA DEPARTMENT Or ENVIRONMENT AND NATURAL RESOu RCES RECEIVED W 2 4 1997 MDREW AND KUSKE Subject: Permit No. SW8 960315 Modification KIA Service Center High Density Commercial Stormwater Project New Hanover County The Wilmington Regional Office received the modification for the Stormwater Management Permit Application for KIA Service Center on November 14, 1997, with final information on November 20, 1997. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000. We are forwarding Permit No. SW8 960315 Modification dated November 20, 1997, for the construction of KIA Service Center. This pen -nit shall be effective from the date of issuance until November 20, 2007, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact Linda Lewis, or me at (910) 395-3900. Sincerely, 1; IZ Rick Shiver, P.G. Acting Regional Water Quality Supervisor RSSlarl: S:1WQSISTORMWATIPERM1T1960315.NOV cc: Phil -Norris; R.E. Tony Roberts, New Hanover County Inspections Beth Easley, New Hanover County Engineering Linda Lewis Wilmington Regional Office Central Files 127 North Cardinal Dr., Wilmington, North Carolina 28405 Telephone 910-395-3900 FAX 910-350-2004 An Equal Opportunity Affirmative Action Fmployer 50% recycled/10% post -consumer paper �f � 7t/ry-, `�� x f/ `- � T f � � ��� State Stormwater Management Systems Permit No. SW$ 960315 ModificLfion STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT 4 In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Donald Mullis, Owner KIA Service Center New Hanover County FOR THE construction, operation and maintenance of a detention pond in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules ") and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until November 20, 2007 and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stonnwater runoff as described on page 3 of this permit, the Project Data Sheet. The stonnwater control has been designed to handle the runoff from 65,550 square feet of impervious area. 3. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 4.. The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans. 2 State Stormwatcr Management Systems Permit &,. SW8 960315. Modification DIVISION OF WATER QUALITY PROJECT DATA SUEET Project Name; KIA Service Center Permit Number: 960315 Modification Location: New Hanover County Applicant: Mr. Donald Mullis, Owner Mailing Address: 2212 Pinehurst Place Wilmington, NC 28405 Application Date: November 14, 1997 Water Body Receiving Stormwater Runoff: Spring Branch Classification of Water Body: "C Sw" If Class SA, chloride sampling results: Pond Depth, feet: Permanent Pool Elevation, FMSL: Total Impervious Surfaces, ft2: Outparcels, ft2 Future, ft2 Offsite Area entering Pond, ft2: Required Surface Area, ft2: Provided Surface Area, ft2: Required Storage Volume, ft3: Provided Storage Volume, ft3: Temporary Storage Elevation, FMSL: Controlling Orifice: VA 34.5 65,550 n/a 3,514 none, per Engineer 2,776 2,917 5,265 7,162 36.5 I" pipe I State Stormwater Management Systems Permit No. SW8 960315 M dification 5. The permittee is responsible for verifying that the proposed built -upon area does not exceed the allowable built - upon area. 6. The following items will require -a modificationto the permit: a. Any revision to the approved plans, regardless of size. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area. e. Further subdivision of the project area. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. In addition, the Director may determine thaiaother revisions to the project should require a modification to the permit. 7. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to lie Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. 11. SCHEDULE OF COMPLIANCE 1. The permittee will comply with the following schedule for construction and maintenance of the stormwater management system: a. The stormwater management system shall be constructed in it's entirety, vegetated and operational for it's intended use prior to the construction of any built -upon surface except roads. b. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. C. All connections into the stormwater system from future areasloutparcels shall be made such that short- circuiting of the system does not occur. 2. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of side slopes. d. Immediate repair of eroded areas. C. Maintenance of side slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of outlet structure, orifice device and catch basins and piping. g. Access to the outlet structure must be available at all times. 3. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. 4. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 4 State Stormwater Manageinent Systems Permit No. SW8 960315 Modification 5. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit; the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. 6. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction. Prior to the sale of any portion of the property, an access/maintenance easement to the stormwater facilities shall be granted in favor of the permittee if access to the stonnwater facilities will be restricted by the sale of any portion of the property. III. GENERAL CONDITIONS This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a fonnal permit request must be submitted to the Division of Water Quality accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143- 215.6C. 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permittee grants DENR Staff permission to enter the property for the purpose of inspecting all components of the permitted stormwater management facility. 6. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. Permit issued this the 20th day of November, 1997. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION \--)— C [ - V�— I:Z� �-, i \' -�- �-- A. Preston Howard, Jr., P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number SW8 960315 Modification State Stormwater Management Systems Permit No. SW8 960315 Modification KIA Service Center Stormwater Permit No. SW8 960315 Modification New Hanover County Engineer's Certification 1, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (period icallylweelclylfull time) the construction of the project, MI (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. Noted deviations from approved plans and specification: Signature Registration Number Date SEAL Cif POND MA iTENANCE REQUTREIITENTS Project Name:_ Permittee: Address:: l G �, i`T. I- C ( / �� iCi ! ji'C PhoneNo. I. Monthly, or after every runoff producing rainfall event, whichever comes first: A. Inspect the trash rack; remove —accumulated debris, repair/replace if it is not functioning. B. Inspect and clear the orifice of any obstructions. If a pump is used as the drawdown mechanism, pump operation will be checked. A log of test runs of the pump will be kept on site and made available to DWQ personnel upon request. C. Inspect the pond side slopes and grassed inlet swales; remove trash, and repair eroded areas before the next rainfall event. D. If the pond is operated with a vegetated filter, the filter will be checked for sediment accumulation, trash accumulation, erosion and proper operation of the flow spreader mechanism. Repairs/cleaning will be done as necessary. II. Quarterly (Four times a year): A. Inspect the collection system (le. catch basins, piping, grassed swales) for proper functioning. Accumulated trash will be cleared from basin grates, basin bottoms, and piping will be checked for obstructions and cleared as required. B. Pond inlet pipes will be checked for undercutting. Riprap or other energy dissipation structures will be replaced, and broken pipes will be repaired. III. Semi-annually (twice a year): A. Accumulated sediment from the bottom of the outlet structure will be removed. B. The forebay depth will be checked at various points. Sediment removal is required when the depth is reduced to 75 % of the original fore -bay desio depth of ' C. Grassed swales, including the vegetated filter if applicable, will be reseeded twice a year as necessary. POND MAINTENANCE REQ S PAGE 2 IV. -Annually (Once a year): A. The pond depth will be checked at various points. Sediment removal is required when the depth is reduced to 75 % of the original design depth or T , whichever is greater. Design depth is ', measured vertically from the orifice down to the pond's bottom. Sediment must be removed to at least the original design depth. V. General: A. Mowing of the side slopes will be accomplished according to the season. Maximum grass height will be 6" . B. Cattails are encouraged along the pond perimeter, however -they will be removed when they cover more than 1/2 the surface area of the pond. The best time to cut them is at the end of the growing season, in November. Environmentally sensitive chemicals for use in killing cattails can also be used. Contact your nearest Agricultural Extension Agent. C. The orifice/pump is designed to draw down the pond in 2-5 days. If drawdown is not accomplished in that time, the orifice will be replaced with a larger or smaller orifice. Slow drawdown may be attributed to a clogged system. The source of the clogging will be found and eliminated. D. All components of the detention pond system will be kept in good working order. Repair or replacement components will meet the original design specifications as per the approved stormwater plan. If previously approved components are determined to be ineffective, the component must be redesigned and/or replaced. VI. Special Requirements: 1. hereby acknowledge that I am the financially (please pruu or type name clearly) responsible party for maintenance! ol'this detention pond. I will be responsible for th'e performance of the r maintenance -as outlined!a ,ove as;part of the Stormwater Management Permit received for this project. Sio-nature: ;� `� `Li V J Date: j Revised V25197 P. 1 COMMUNICATION RESULT REPORT ( APR.29.2004 10:14AM )TT * I NCDENR WIRO ------ RESULT PAGE OPTION - ----- ADDRESS (GROUP) ------------------------ .LE MODE ------------------------- E-3)3)3)3)3) P. 0/2 -- ----- ------------------ - 93439653 7 MEMORY TX REASON FOR ERROR E-3) No ANSWERUP R LINE FAIL E-2) BUSY E-4) NO FACSIMILE CONNECTION State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Michael F. Easley, Govemor William G. Ross Yr., Secretary FAX COVER SHEET Date: To: CO: FAX # � i - ! 4Jr.3 AEMARKS No. Of Pages: % From: FAX#: 910-350,2004 I27 Cardinal Dt•ivc Extension, Wilmington, N.C. 28405-3945 Telephone (9I0) 395-3900 For (910) 350,2004 An Equal Opportunily Affirmative Actlon Employer r State of North Carolina. Department of Environment and Natural Resources Wilmington Regional Office Mt'chael F. Easley, Governor William G. Ross Jr., Secretary FAX COVER SHEET Dite: �-/a 3 LOX TO: FAX #: &3 - 'LOV — --r /I R.FMARKS No. Of Pages: From: �.✓ - �.6 CO: 1t/Gl� FAX#: 91(050�200 127 Cardinal Drlvo E%tenslon, Wllmlagton, N.C. 29405-3845 Telephono (910) 395-39" Fax (910) 350-2004 An Equal opportunity Afllrmaiive AWon Employer State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Michael F. Easley, Governor William G. Ross Jr., Secretary FAX COVER SHEET Date: To: FAX # 'lkl- Ici9) _3 V3 - '7GS 3 REMARKS No. Of Pages: CO: 1-0C_ wlt2 FAX#: 910-350-2004 127 Cardinal Drive Extension, Wilmington, r.C. 28405-3845 Telephone (910) 395-3900 Fax (910) 350-2004 An Equal Opportunity Affirmative Action Employer P. 1 COMMUNICATION,RESULT REPORT ( APR.23.2004 10:36AM—)-,*� + TTil NCD i FILE NODE OPTIO'!' ADDRESS (GROUP) RESULT 1 -------------- f------------_------------------------ _--------------------_—------------ ---- 143 MEMORY TX 93439604 OK 1 -------------------------------------------- REASON FOR ERROR E-1) HANG UP OR LINE FAIL E-2) BUSY E-3) NO ANSWER E-4) NO FACSIMILE CONNECTION State of North CarofiU4 Department of Environment atW Natmil Rosouroas Wilmington Regional Office M6ael F. Easley, Qovarnor William 4. Ross Jr., Sometary FAX COVER SHEET We: z 3 o No. Of Page: 6 T4: From: Del FAX M. 3U 3 FAX.#: 21UIQ- 004 �I ���I 1�^� Tr 127 Cardlnel Drlva Eximshm WilailaWt6 N.C. 20445•ME TdgAwto 010) 393400 Sax MO) 35D4"o An Iqual 90partAWW Atflrm ON Actlaq Mayor NR WIRO PAGE —P.T 11/11 i r A&K 97342 DIVISION OF WATER QUALITY NORTH CAROLINA STORMWATER MANAGEMENT PERMIT APPLICATION I. GENERAL INFORMATION (Please print clearly or type) 1. Project Name: KIA Service Center 2. Location, directions to project (include County, Address, State Road) Attach map. New Hanover County_, at Intersection of Market Street and Old Eastwood Road 3. Owner's Name: Donald Mullis 4. Owner's Mailing Address 2212 Pinehurst Place Phone: 910-392- l 000 City Wilmington State 5. Nearest Receiving Stream Spring Branch/Smith Creek 6. Project description NC Class C-SW Zip 28405 Car sales lot at intersection of Market Street and Old Eastwood Road, located in New Hanover County. IL PERMIT INFORMATION 1. -Permit No.(1'o be filled in by DWQ) 2. Application Date November_] t, 1997 Fee enclosed S $395 00 3. Permit Type New Renewal X (Md.dification(eXistingPerntit No. ' W8-9601 5— _1 4. Proj Type Low Density X Detention Infiltration Redevelop General Alter Offsite 5. Other State/Federal Permits/Approvals Required (Check appropriate blanks) CAMA Major Sedimentation/Erosion Control X III. BUILT UPON AREA (Please see NCAC 2H.1005 thru .1007 for applicable density limits) Classification Existing Built -upon Area Proposed Built -upon Area Including 3,514sf future Total Project Area % Impervious Area 404 Permit Drainage Drainage Breakdown of Impervious Area Basin Basin (Please indicate below the design impervious area) C-SW Buildings: Ex = 2,750sf, New = 5,376sf �s Streets 20,000 sf Parking/SW Ex = 42,800sf, New = 11,l 1Osf 83,635 sf Other: Future max = 3,514sf 78.38% Totals 65,550 sf IV. STORMWATER TREATMENT (Describe how the runoffwill be treated) Detention Pond e r r V. DEED RESTRICTIONS AND PROTECTIVE COVENANTS Deed restrictions and protective covenants are required to be recorded for all low density projects and all subdivisions prior to the sale of any lot. Please see Attachment A for the specific items that must be recorded for the type of project applied for. By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the items required by the permit, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the covenant cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot. VL OWNER'S CERTIFICATION I, Donald Mullis , certify that the information included on this permit (Please print or type name c ear y application form is correct, that the pro' twill be constructed in conformance with the approved plans, that the deed restrictions will b r th all required permit conditions, and that to the best of my knowledge, the deed restrictions will burhe proposed project corppv d the requirements of 15A NCAC 2H.1000. I authorize the or firm to submit stormwater plans on OWA Owner/Authorized Agent Signature and Title VII. AGENT AUTHORIZATION (MUsrBECOMPLETED) Person or firm name J. Phillip Norris, P.E./ Andrew & Kuske Consulting Engineers, Inc. Date Mailing Address 902 Market Street City Wilmington State NC Zip 28401 Phone 910-343-9653 Please submit application, fee, plans and calculations to the appropriate Regional Office. cc: Applicant/WiRO//Central Files NOV 141997 IN, FIM 9-3439604 Nov 19 '97 11:45 State No h Carolina of No of Environment,ealth and Natural Resources Wilmington Riglional Office Jamei B. Hunt Governor Wayne McDevitt, Secretary Date: 11-1'(—T- To: Phil! Uort-l'-5 CO; FAX FAX COVER SHEET qages: , - 4� Fr m: L-Jlr2- 6'4/,'`s FAXN: 910-350-2004 .maid MU//I'-5 k) M rlr)-Iz-c?ra P' 127 Ordinal �Iinsl Drive Extens[on, Wilmington, N.C. 28405.3ig45 Telephone (910) 395-3900 Fox (910) 3SO-2004 An Equal Opportunity Affirip6tive Action Employer. State of North Carolina Department of Environment, Health and Natural Resources Wilmington Regional Office James B. Hunt, Governor FAX COVER SHEET Date: Il- IR-q- - To: Phil Uor-rl'S CO: 4•,d,-evj a rvske- FAX #: 34v cf(.oC)± _ REMARKS : ' Phi + — -r n aekM {t+- + Wayne McDevitt, Secretary No. Of Pages: 1 From:. L/iJ z L t?.uro S CO: 5W-8 9W_3!S CIA FAX#: 910-350-2004 eqr i/i-eet-s Car hi'r 1. //I--5 tU Sr 127 Cardinal Drive Extension, Wilmington, N.C. 28405-3845 Telephone (910) 395-3900 Fax (910) 350-2004 An Equal Opportunity Affirmative Action Employer. 1Kt;1L;Jt'I V L.L John R. Andrew, P.E. Andrew & Kuske NOV 14 1997 J.A. Kuske, P.E. CONSULTING ENGINEERS, INC. J. Phillip Norris, P.E. 902 Market St. • Wilmington, North Carolina 28401-4733 53 • Fox 910/343-9604 November 13, 1997 NC DENR Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Attn: Ms. Linda Lewis Re: KIA Service Center Permit Name Change & Modification A&K Project No. 97342 Dear Ms. Lewis: Enclosed is a permit name/ownership change form and associated fee of $100.00 for the subject project. Also enclosed are three sets of plans, the Division of Water Quality stormwater management permit application and a $385.00 check for the processing fee for a permit. modification. Please review this information for approval and contact us with any questions or comments you may have. Thank you for your assistance on this project. Sincerely, ANDREW & KUSKE CONSULTING ENGINEERS, INC. Phillip Norris, P.E. JPN/sbs enclosures cc: Donald Mullis Monty Talley/All Span 97342SW '`- State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E. Director WATER QUALITY SECTION PERMIT NAME/OWNERSHIP CHANGE FORM I. CURRENT PERMIT INFORMATION: Permit Number: I SjWj 81 9 6 01 3 1 5 I. Permit holder's name: Evstam. L.L. 2. Permit signing official's name and title: Wayne Stamey (Person legally responsible for permit) Managing Partner (Title) 3. Mailing address: 5106 Market Street City: Wilmington State: NC Zip Code: 28405 Phone: (910) 392-4300 II. NEW OWNER/NAME INFORMATION 1. This request for a name change is a result of: x a. b. C. Change in ownership of property/company Name change only Other (please explain): 2. New owner's name (name to be put on permit): KIA Service Center 3 4 New owner's or official's name and title: Donald Mullis (Person legally responsible for permit) Owner (Title) Mailing address: 2212 Pinehurst Place City: Wilmington State: NC Zip Code: 28405 Phone: (910) 392-1000 THIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL OF THE APPLICABLE ITEMS LISTED BELOW ARE INCLUDED WITH THE SUBMITTAL REQUIRED ITEMS: This completed application 2. Processing fee of $100.00 (Checks to be made payable to DENR) If an ownership change, legal documentation of the transfer of ownership (such as a contract, deed, articles or incorporation) CERTIFICATION MUST BE COMPLETED AND SIGNED BY BOTH THE CURRENT PERMIT HOLDER AND THE NEW APPLICANT IN THE CASE OF CHANGE OF OWNERSHIP. FOR NAME CHANGE ONLY, COMPLETE AND SIGN THE APPLICANT'S CERTIFICATION. Current Permittee's Certification: I, Wayne Stamey _ , attest that this application for name/ownership change has been reviewed and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned as incomplete Signature: Date: 11117,117 7 Applicant's Certification: 1, Donald Mullis , attest that this application for name/ownership change has been reviewed and is accurate a c plete o the best of my knowledge. I understand that if all required parts of this application are t and that if all required supporting information and attachments are not included, this c o kage will be returned as incomplete Signature: Date: l l �L 92 THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: North Carolina Department of Environment, Health, and Natural Resources Division of Environmental Management 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Telephone: (919) 395-2900 Fax: (910 350-2004 State of North Carolina V Department of Environment, O Health and Natural Resources A74 Division of Environmental Management James B. Hunt, Jr., Governor H Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director May 7, 1996 Mr. Wayne Stamey Evstam, L. L. C. 5106 Market Street Wilmington, North Carolina 28405 Subject: Permit No. SW8 960315 Evstam Car Lot High Density Commercial Stormwater Project New Hanover County Dear Mr. Stamey: The Wilmington Regional Office received the Stormwater Application for Evstam Car Lot on March 15, 1996, with final information on April 12, 1996. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000. We are forwarding Permit No. SW8 960315 dated May 7, 1996, to Evstam, L.L.C.. This permit shall be effective from the date of issuance until May 7, 2006, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an ajudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact Linda Lewis, or me at (910) 395-3900. Sincerely, r_J_�`CC 5 (--) k`�-/'T l- �C, Dave Adkins Regional Water Quality Supervisor DA/arl: S:IWQSISTORMWATIPERMIT1960315.MAY cc: Phil Norris, P.E. Alan Golden, New Hanover County inspections Beth Easley, New Hanover County Engineering Linda Lewis Wilmington -Regional -Office,. Central Files P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer State Stormwater Management Systems Permit No. SW8- 9603I5 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL MANAGEMENT STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Evstam, L. L. C. Evstam Car Lot New Hanover County FOR THE construction, operation and maintenance of a Detention Pond in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Environmental Management and considered a part of this permit. This permit shall be effective from the date of issuance until May 7, 2006 and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described on page 3 of this permit, the Project Data Sheet. The stormwater control has been designed to handle the runoff from 65,550 square feet of impervious area. 3. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 2 State Stormwater Management Systems Permit No. SWS 960315 DIVISION OF ENVIRONMENTAL MANAGEMENT PROJECT DATA Project Name: Evstam Car Lot Permit Number: 960315 Location: New Hanover County Applicant: Mr. Wayne Stamey Mailing Address: Evstam, L.L.C. 5106 Market Street Wilmington; North Carolina 28405 Application Date: March 15, 1996 Water Body Receiving Stormwater Runoff: Spring Branch Classification of Water Body: "C Sw" If Class SA, chloride sampling results: NIA Pond Depth: 7 feet Permanent Pool Elevation: 34.5 MSL Total Impervious Surfaces Allowed: 65,550 square feet total including future area. Future 20,000 square feet Offsite Area entering Pond: N/A square feet Green Area entering Pond: 18,085 square feet Required Surface Area: 2,776 square feet Provided Surface Area: 2,917 square feet Required Storage Volume: 5,552 cubic feet Provided Storage Volume: 7,162 cubic feet Temporary Storage Elevation: 36.5 MSL Controlling Orifice: 1 " pipe 3 State Stormwater Management Systems Permit No. SW$ 960315 4. No property owner/developer shall fill in, alter, or pipe any vegetative practices (such as swales) shown on the approved plans as part of the stormwater management system without submitting a revision to the permit and receiving approval from the Division. 5. The tract will be limited to the amount of built -upon area indicated in the supporting calculations and per approved plans. 6. Deed restrictions must be recorded prior to the sale of any outparcel or future area shown on the approved plans to ensure that future owners are made aware of the built -upon area limitations. The following statement must be recorded: "To ensure continued compliance with the NCDEM Stormwater Management Permit Regulations, 15A NCAC 2H.1000, outparcel(s) and future areas as shown on the approved plans are limited to 20,000 square feet of built -upon area, inclusive of that portion of the right-of-way between the front lot line and the - edge of the pavement, structures, pavement, walkways of brick, stone, slate, but not including wood decking or the water surface of swimming pools." "All built -upon area from the outparcel or future area must be directed into the permitted stormwater control system." "Additional built -upon area will require a permit modification." 7. The permittee is responsible for verifying that the proposed built -upon area does not exceed the allowable built -upon area. S. The following items will require a modification to the permit: a. Any revision to the approved plans, regardless of size. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area. e. Further subdivision of the project area. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. In addition, the Director may determine that other revisions to the project should require a modification to the permit. 9. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. 4 State Stormwater Management Systems Permit No. SW8 960315 II. SCHEDULE OF COMPLIANCE 1. The permittee will comply with the following schedule for construction and maintenance of the stormwater management system: a. The stormwater management system shall be constructed in it's entirety, vegetated and operational for it's intended use prior to the construction of any built -upon surface except roads. b. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. C. All connections into the stormwater system from future areasloutparcels shall be made such that short-circuiting of the system does not occur. 2. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in it's entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of side slopes. d. - Immediate repair of eroded areas. e. Maintenance of side slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of outlet structure, orifice device and catch basins and piping. g. Access to the outlet structure must be available at all times. 3. Records of maintenance activities must be kept and made available upon request to authorized personnel of DEM. The records will indicate the date, activity, name of person performing the work and what actions were taken. 4. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 5. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. 6. A copy of the recorded deed restrictions must be submitted to the Division within 30 days of the date of the recording. The recorded copy must be signed by the permittee, dated, stamped with the deed book number and page, and bear the stamp of the Register of Deeds. 7. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction. 0 State Stormwater Management Systems Permit No. SW$ 960315 III. GENERAL CONDITIONS This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Environmental Management accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Environmental Management, in accordance with North Carolina General Statute 143-215.6(a) to 143-215.6(c). 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. Permit issued this the 7th day of May, 1996. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION t�CC_� S k'0 s- t- r cD (-,,L— A. Preston Howard, Jr., P.E., Director Division of Environmental Management By Authority of the Environmental Management Commission Permit Number SW8 960315 2 State Stormwater Management Systems Permit No. SW8 960315 Evstam Car Lot Stormwater Permit No. SW8 960315 New Hanover County Engineer's Certification I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. Noted deviations from approved plans and specification: Signature Registration Number Date 7 E DIVISION OF ENVIRONMENTAL MANAGEMENT A&x 95315 NORTH CAROLINA STORMWATER MANAGEMENT PERMIT APPLICATION 1. GENERAL INFORMATION 1. Project Name Evstam Car Lot 2. Location, directions to project (include County, Address, State Road) Attach map. New Hanover County, NC intersection of Market Street and Old Eastwood Road (See Vicinity Map on_plan). _ 3. Owner's Name Wayne. Stamey, Evstam; LLC 4. Owner's Mailing Address 5106 Market Street Phone 910-392-4300 City Wilmington State NC Zip 28405 5. Application date March 14 1996 Fee enclosed $385. 00 6. Nearest Receiving Stream Spring Branch/Smith Creek Class C-SW 7. Project description Car sales lot at the intersection of Market Street and Old Eastwood Road, located in New Hanover County, NC. II. PERMIT INFORMATION I. Permit No. (To bt Cd]ad in by DEM) 5W -Y %013l S 2. Permit Type x New Renewal Modification (existing Permit No.) 3. Proj Type Low Density x Detention Infiltration Other Redevelop Gen'1 4. Other State/Federal Permits/Approvals Required (ch. gprWriam blank) CAMA Major Sedimentation/Erosion Control x 404 Permit 111. BUILT UPON AREA (Pl. Itz NCAC 2H. I005 thm . lam ctr apprwble deasity limits) DrainU a Drainage Bain Basin Classification C-SW Allowable Impervious Area a o n n l c n n� Total Project Area 1. 92AC/83, 635. 20SF Proposed Impervious Area SF w5550 $f per TAK % Impervious Area �-} =Wl- 7 9.13 % _re . cz k5 1V. STORMWATER TREATMENT (Deuibeaowth n,,.ffwiiibcmt.4 Dir Cert 'Breakdown of Impervious Area (rlem a,dic= Wow Ux design impervious area) Buildings Z Sj24 SF 27So Streets N/A 1500 - SW Parking/SW -Q� SF -g1300 - P2rlL Future Impervious Other 20,000SF maximum Totals -b6;, SF 65, 550 K *See calculations. The runoff will sheet flow off the proposed impervious areas across grass into the collection system which will convey the runoff into the proposed detention pond designed to achieve 90% TSS removal. V_ DEED RESTRICTIONS AND PROTECTIVE COVENANTS Deed restrictions and protective covenants are required to be recorded for all low density projects and all subdivisions prior to the sale of any lot. Please see Attachment A for the specific items that must be recorded for the type of project applied for. By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the items required by the permit, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the covenant cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot. VI. OWNER'S CERTIFICATION I, Wayne s tamey , certify that the information included on this permit trl'. prim or type == dcuiy) application form is correct, that the project will be constructed in conformance with the approved plans, that the deed restrictions will be recorded with all required permit conditions, and that to the best of my knowledge, the proposed project complies with the requirements of 15A NCAC 2H.1000, I authorize the below named person or firm to submit stormwater plans on my behalf. gent signature V I I . AGENT AUTHORIZATION (musr 6F compi=. —.n) Person or firm name Andrew &_ Kuske Consulting Engineers, Inc. Mailing Address 202 North Fifth Avenue City Wilmington State NC Zip 28401 - Phone 910-343-96 Please submit application, fee, plans and calculations to the appropriate Regional Office. cc: Applicant/WiRO/Central Files TOOffioce use only, E C E I V E MAR 1 51996 D E M PRoJ # 3gco�315 1 STORMWATER MAINTENANCE SYSTEM MAINTENANCE PROCEDURES EVSTAM, LLC A&K PROJECT NO.95315 RESPONSIBLE PARTY A. The project will be built and maintained by: Evstam, LLC 5106 Market Street Wilmington, NC 28405 910-392-4300 2. DETENTION POND AND COLLECTION_ SYSTEM EC,EIVE MAR 15 1996 PROJ # -4 F `ICv03/ 5 A. The detention pond will be checked after every major storm event to insure that the outlet structure is working properly and is not clogged with debris. Remove any accumulated sediment or debris. Any signs of erosion or deterioration of the pond side slopes or any other feature must be repaired before the next storm event. B. The depth of the pond will be checked every six months to determine the depth of the permanent pool. The pond will be cleaned out when silt deposits reduce the depth of the permanent pool below 5.25 feet. The side slopes of the pond shall be mowed as required to maintain a grass height not to exceed 8 inches in height. C. Collection basins and piping will be checked every six months and kept clear as necessary. 3. CERTIFICATION The owner will submit to the Department of Environment, Health and Natural Resources an Engineer's Certification that the stormwater facilities were constructed in accordance with approved plans. 31y & gnature Wayne NOTARY'S CERTIFICATION State of /V,4& 1 (,-&9o1 j;AJA County of gjo 1, , a Notary Public in and for the State and County aforesaid, certify that IJAV,06 qTeq177&, personally appeared before me this day and acknowledged the due execution of the foregoing instrument. WITNESS my hand and notarial seal, this the l of '01AW4 , 1999. My Commission Expires: I1AZ-d Do C7 I Andrew & Kuske CCNSIiPING ENGINEERS, INC. 202 North Fifth Avenue Wilmington, NC 28401 APR 12 1996 LETTER OP TRANSMITTAL John R. Andrew, P.E. J. A. Kuske, P.E. J. Phillip Norris, P.E. Telephone: 910/343-9653 Facsimile: 910/343-9604 To: Date: Job No.: Attention: Subject: WE ARE SENDING YOU VIA () Shop Drawings [ Prints ATTACHED [] UNDER SEPARATE COVER [] Tracings [) Specifications [] Disks [] Copy of Letter FAX TRANSMITTAL: NUMBER OF PAGES INCLUDING THIS TRANSMITTAL Call 910/343-9653-if you have any difficulty receiving this message COPIES DATE NO. DESCRIPTION L S 2vc�nap ��d T rW vu�+a ernUUa U-M.uu PROJ #5(1 THESE ARE TRANSMITTED AS CHECKED BELOW: [ For Approval [) For Your Use [�s Requested [] For Review and Comment [] No Exceptions Taken [J Make Corrections Noted [J Amend and Resubmit [] Your Prints Returned After Loan To Us (] Rejected -See Remarks () Returned For Corrections [] Return Corrected Prints [] FOR BIDS DUE [] REMARKS: /`in/xi a cis' •To ,DEG- >'.h�,�' .dc?�.0 . G�i�-G c:✓/.r.�r� ,�Qc.�,�� J��../J' CC., ✓1 r'7✓L� iy/v //��VT /[r��v�Glr�- ��%�iyv� ' Signed: CONFIDENTIAL AND PRIVILEGED: Information contained in this document is privile d and confidential, intended for the sole use of the addressee. If you are not the addressee or the person responsible for delivering it to the addressee you are hereby notified that any dissemination, distribution or copying of this document is strictly prohibited. If you have received this document in error please immediately notify the sender and return to the address above. Vbg I iKO C- Date Design Andrew and Kuske Sheet 202 N. Fifth Ave. CONSULTING ENGINEERS, INC. Wilmington, N.C. 28401 Of Check Job STirTE For /-Z—:- Job No. GodS- //Erry yynrovE•C Crx.•,.WY .0 A'/L T A L . lip I1966 51 o by 14 -.;'stVi��Q��,: LLiP,n STOMAINATER Q E C E I V E APR 1 21996 U PROJ # S %o3l5 Date Design Andrew and Kuske Sheet 202 N. Fifth Ave. CONSULTING ENGINEERS, INC. Wilmington, N.C. 28401 Ot %U Check Job For Job No, /,017®�l-e. &14-f7;t . c 4 n r- 953�5_ /r7�E2 v/ac/S G�9L.� vL �1T7c��./ /1/0725- TifF = oer- Q //.JG / f�i9�[ /i�Yr G�T.f /f CCT r OiC / c �FJ' /fit//J /JGG `..T•.T !✓/lam /Q'.f . �} �/ �:U11 /.7T o / �//rC_ /d ,SGd ..J•` af= / �.oEz vio c..<.% ��f � /r BE /i✓G`�pd.� F p F� Fv7v4E o?V,ritit�— �Fvre%CE = /, 9z ---16 / 8 3/ / 3.5-, 2- v s,r z7So /Soo s� 3-0 o s� 24/ G�ca SF /rloE� ✓/�-� .rc�,y c /. SdifC x = A 5z-AL Sv��•f.� y 7aT�L 7� � l` � 4.c �i.vrJC� ?.«�7 = /• �! 2 �C / 83� 6 3S • Z o SF To r?Z /�-i v� mac. G��wJ /t�GE�f - / S� •9C / 1p S S,5'"O ,s � /VOTE /i'►7//C� ua�.f i?Tz EilS W f�� C�C.G c.�. ?Tta F.Go �7 i9e/Tp C -74Q /✓07E : %YE Q' OLW Gaff/G tiE4 7a Fob 2a/ C00 slo- e. /0 GETf TiYi9.✓ 20 pGb .fiC /> </E TU /2e/Az//TL /.f c?L E ate✓ .r/Te , Date Design Andrew and Kuske Sheet 31711y(� -�' L� 202 N. Fitth Ave. CONSULTING ENGINEERS, INC. Wilmingson, N.C. 28401 Of / U Check Job Sr�r� For ,E✓ST�i� l Job No. -il��`'?7T'C L'.-'�`�vf CGvT^r1S3/S %ii9'4 = 4 GJz ifC/ e31 6,YT Zo ,S� TbT�tC ♦ /f.G v�iri f �iGE? /, SD -'7G / 66-,- SSv S/c 78. /3 7o G�c Ems/ � dif = %Ti�C Tx ?�T" -- i �►ii� 83, G3S. �sy - 6S SSc� SF o SS o p �z 04 ^/Efi� ?b C .yQG .m S7z�2 F $ 7�0 ¢ F T 3 FGoot1 f,�L 36, Sp 3 5z, se> ,6a777b .-r = Z7, 5`a 4- n/EEQ 7 ' ��r�r�Y /1 T ``� �'7�9 �/cr .-✓ r ,ao o C Fa •� 90 % Trf �EMocr/!'[ �T 76. /.3 % dEr iT/Ty x W 79, /,3 dl, X, = -70 xz=Bo yz=3,4 /a9 .3. 9 - z. 5 79.13 - 7o J t 2 , 9 7- S'�/ate = 3.To6s ,eEcavi rEo SR - D. �CEOc./�.E 4 Svc f ABC rriC�.4 .y �- n/0,4f - +M i2::;PoG = Z 7 6, `T z Date Design Andrew and Kuske Sheet 202 N. Fifth Ave. CONSULTING ENGINEERS, INC. Wilmington, N.C. 28401 t Of/O Check Join Sr.rr� Eor �sr�--7 b No. S 3/S` i .EXGE�IJ-T Th�� Sv�F?�F r�c,�it i2E'Q�.vr.,GGo �TDiC� G� CA"z GC�G/T"I7� � 4p NEEiJ .voG,ti.rL i✓Oo C �,ti.Q .—IIaoQ ,oae:)c_ C I Sr//C Fi'1G E E/J� T C -T L C 76'sS / Z 9/ 7 -7 r x z 7/(Z /39S `T�EXTx9 7-f� .r�zi���� �/La✓iQ��J ExcEEol i /./orz! -17f-E i CA CG r� c �� 4 Frio ^'t �ti7� CiT+OD Date Design Andrew and Kuske Sheet 202 N. Fifth Ave. CONSULT[NG ENGINEERS, INC. Wilmington, N.C. 28401 � Of �D Check Job ,STATE 1 For �fr�ye-7 Job No. /2.E oe-,TzI .pT e-1.3¢. Sod S y z e,--r 4 J`at9 r��✓ `o.� fTz,�C�T G� P.C'o c�/Q L,O 7z, Soa 7Tdz� 4.oO Sf FTz O, /0 47 FT z " Np.cr-r�lC. �vnC �jr��� �-� /�4ti�0 L✓i<G Q�?��-� �v�/ �.v z - 3 ohs. OvTZEr f% c.c !_� CiY£CiC Z'X 3' /3�i�•/ f STb.c .-7 c /Ci T� i? Fo2 4 �iG r-T i•-- ���ri.-✓ C� G /iy Z = 4 • Z j- i.y/ `/� iM�C.c rr�,l = �/, BS Flo -9 = /, �z n c = 0. '75- �/O, 7 /88 j f e9, Zca (p, I o, 7 Q= (a �)C V.zsJC /, sc) - z-a,,a- cis 1 ��-s is Ems, �-rr�� o� I �✓.�-r� = 3C, s`o t 0 7 To.� a� a�•e = 3B. ov I �/o �Gv� oi..x I o Hate Design Andrew and Kuske Sheet --T'7X 202 N. Fifth Ave. CONSULTING ENGINEERS, INC. Wilmington, N.C. 28401 S Oq /lam Check Job STATE For �1/.TTi! •-� Job No, Gh'6c� v.v40X2 G.r it✓iry Go-�4lr��--✓ �h-�rJ � .yTJ /f �✓ 2 b d f/i7•.�OGE ip�•ocxi.-�?'TL � Y 8. � O cF.s' a -yok 7"p %?rE !p y.��t� 3d vy�..�vr i'Tb.c�7 Q=- ,46 77>�C /3o17z ^'1 OF T/YE fPiGG1-�Ji7"Y GviGG IlC i7-T EG EvJ 3 7 � . �9�u .-� c 7N.rT 77s� tirrx� � �---► h����iir~ of" G✓�tTr� cvic c �� o.so ' . 7?fY� G-1/cc G��la� o. S� ' Q 6, cal Cam✓" Cw G 3. o </ ;-.- o. S ' s- L= C� G a s S: 7 (0, Sf ins V= Q _ 0 9 /, 2/ V = /, z / �Os G/.vE f.�/6G �✓�y �.//T.�/ G,2.7,%f J Exhibit 11 0 1eo 10,000 168 0,000 EXAMPLE { I) (2} (3) 156 6 OOa D•42 Inch" (3.5 feet) 6. 144 5000 o•IxD Cfe , 3. 4,000 � a hlr 6• 5. 132 D feet 3,000 g 4. I20 (l) !.s 0.0 4. (2) 2.1 TA 108 2,000 (3) 2.z T.T 4• 3. ,D In feel 3 96 1.000 3' Soo 84-- 600 / 2. 2` / 500 72 400 2. in w _ 300 ��`� _ `-- 1.5 U Z N �x� / N 1.5 Z 60 v 200 � w 1.5 H 54 a_ o Cr / w 100uj Q > 48 Ix 80 ? � 4 Z �Q N 60 w 1.0 1.0 o 50 HW ENTRANCE ar a 40 D SCAL TYPE x 1.0 w Uj �`' 36 30 (I Square edge with w 4 9 9 33 hoodwall 3.9 o a Q 20 (2) Groove end with a w 30 headwall = e .8 I3) Groove end .8 27 proJeetkng 24 ° 7 .T .7- 6 To was %Cole (2) or (3) project 21 S horizontally to scale (I),then 4 use siratghl Inclined fine through D and o scales, or reverie as 6 3 illustrated. •6 18 2 Q- 8r. 40 GG1' T 15 'S .S I.0 ' � HEADWATER DEPTH FOR HEADWATER SCALES 293 CONCRETE PIPE CULVERTS REVISED MAY 1964 WITH INLET CONTROL BUREAU fX rMJ•t,IC ROADS JAIL tfQ VI-11 Date Design Andrew and Kuske Sheet 3/7,"F6 202 N. Fifth Ave. CONSULTING ENGINEERS, INC. Wilmington, N.C. 28404 7 Of Check Job STi/rE For Job No. STd/1 �vr1x/L �-fcc �t7T�.-J Grr� Go7� 95,E/S Q TrC/. Z sJ Z �,eo.r7 T�9!!Lt T' `F, ¢-3 GCl.E S-XC J— /-- /\if- 4:7,,7— CGzep-r/d-OrZ ^Zr TrC/. Z sJ Z �,eo.r7 T�9!!Lt T' `F, ¢-3 GCl.E S-XC J— /-- /\if- 4:7,,7— CGzep-r/d-OrZ ^Zr once the average v locity CCEImrted as: _ L W Tt 3600 V is dete=jxjed , the travel time can be (3) open Channel Floss - For open cannel flow, the travel time is compated using an estimted velocity of flow in the channel section. J' The velocity is estimated using Manning's equation expressed as follcws: '. 1.49 f x n %&ie. e V is velocity in feet per secorri (fps) r is the hydraulic radius whidY is equal to the diarT l area d iv itde by the wetted perimeter or the peri.mcter lerr th of sides and bottom below the line of flow. s is the slope of the hydraulic grade line or channel . slope in ft,/ft and n is the Manni g' s _rnugh*ess ccef f icient once the average velocity is determ.Lned Er m the above equation, the travel time can be ccmputed as in 2. above. The time of traticn, Tr-, is a nmmatian of t►Ze three travel ' times cmxrted in the preceding steps. The rainfall intensity for design can be ,cbtained fran the L tersity- L Duration-Frequwwncy Table or the equation provided below. The return period for design in the City of Wilmirnton for storms.ater Ott systems is the 10--year return frequ� everrt. WnMaciW, i3C RfftLIr n Period -> DURATICN 2-yr 5-yr 10-yr 25-yr 50-yr 100-yr ` 5 min 5.98 6.63 7.23 8.15 .8.87 9.60 ' 10 min 5.06 5.76 6.30 7.13 7.79 8.45 15 min 4.36 4.97 5.45• 6.17 6.75 7.32 . 30 min 3.17 3.79 4.25 4.92 5.44 5.96 60 min 2.10 2.58 2.92 3.41 3.80 4.18 2 hr 1.18 1.47 1.67 1.96 2.19 2.41 3 hr 0.88 1.10 1.25 1.47 1.65 1.82 6 hr 0.55 0.70 0.80 0.95 1.07 1.18 12 hr 0.33 0.42 0.48 0.57 0.64 0.71 24 hr 0.19 0.24 0.28 0.33 0.38 0.42 Master Draiz-oge ImpruveMEnt & Stormwater Marsagemerrt Plan, Vol. Mcici m & Creed, .huge 1968. . 1, '� T-9 . 21 r r �eBlr f. Lt:7,i} i nL66. L `" ' C i Iok�ir ESTIMATION OF STONE SIZE AND DIMENSIONS FOR CULVERT APRONS 2* 20 Ul �1 r l , 15 w tll l 1. z 10 J 5 ! 1 I I I I 1 I t I r 1 I I t I I 1 I I r I 1 I I L_— 1 I I ! I --i-- 1 I E I 51 ! I i r I I 1 I 1 1 - 1 Z I I ! I 1 I f I I I 0 5 10 15 20 25 D IN FT. 5tcp I> Esltmale flow vtloclly Va al cuiveft or paved chonnel oullel. Step 7> For pipe culverts Do Is dlomsler, For pipe arch, arch and box culverls and paved chonne.1 "Oats. Do w A a. inhere A a - uoss secllond area al low at outlet. , For multiple wlverls, use O a" 1.25 v 0 a of single culverl. Step 3> For apron grodeol of lox of Blooper, use rscornmendoilons for next higher tone (zones I lhru 5) o N APRON MATERIAL LENGTH OF APRON TO PROTTCT CUL%TRT LI TO PREIANT SCOUR IIOLE L2 I Slone F11Iing (Fine) 3 r p o 4 i D o 7 51one filling (Light) 3 X D a b X D o 3 51ons filling (IJedlum) 4 s D a O r D a 4 Slone filling (heavy) 40 D o a e D a S Stone F=Itng (IIaavy) 5 r p o 10 s D a 6 Stone flung (lisavy) 6 e D o 12 a D o 7 Speclol study requtred (anergy dlstpalors, sluing basin or larger stone site.) SOURCE BANKS AND CHANNEL LINING PROCEEDURES, N.Y.D.O,T., DIVISION OF DESIGN AND CONSTRUCTION, 1971 r NORTH CAROLINA DEPARTMENT OF TRANSPORTATION RALEIGH STANDARD SPECIFICATIONS FOR . ROADS AND'STRUCTURES SECTION 942 ,t RIP RAP MATERIALS 942-1 PL.NIN RIP RAP. Slone for plain rip rap shall consist of field stone or rough unhewn quarry stone. The stone shall be sound. tough, dense, resistant to the action of air and ~cater. and suitable in all other respects for the pur- pose intended. Where broken concrete from demolished structures or pavement is available, it may be used in place of stone provided that Such use mevts with the approval of the Engineer. However, the use of broken concrete which contains reinforcing steel will not be permitted. The stc:,.e or broken concrete shall be graded to meet the Following requirements: 1. For Class 1 Rip Rap. Stone shall vary in weight from 5 to 200 pounds. At least 30 percent of the total weight of the rip rap shall he in individual pieces weighing a minimum of 60 pounds e:,ch. Not more than 10 percent of the total weight of the rile rap matt• he in individual pieces weighing less than 15 pounds each. 2. For Class 2 Rip Rap. Stone shall vary in weight from 25 to 250 pounds. At least 60 percent of the total weight of the rip rap shall be in individual pieces weighing a minimum of 100 pounds each. Not more than 5 percent of the total weight of the rip rap may be in individual pieces weighing less than 50 pounds each. 942-2 S'ITONE FOR EROSION COIv'TROL. The stone shall be of a hard, durable nature and shall range in size as follows: Class Size A 2.- 6" B V-15' All stone shall meet the approval of the Engineer. while no specific gradation is required, the various sizes of stone shall be equally dis- tributed within the required size range. The size of an individual stone particle will be determined by measuring its long dimensions. ATTACHMENT A LOW DENSITY AND SUBDIVISION PROJECTS GENERAL SUBMITTAL REQUIREMENTS 1. A completed stormwater permit application. 2. Two sets of plans showing north arrow, scale, revision date, property/project boundaries, lot lines, proposed and existing contours, drainage areas, mean high water line, wetlands, easements, the 30' minimum vegetated buffer between impervious areas and surface waters, proposed impervious areas, and road cross -sections. 3. Calculations of the build -upon area, for subdivisions, please show the methodology for arriving at the per lot built -upon area. For non -subdivision projects, please break down the calculation into buildings, roads, parking, and other (include all impervious areas). 4. Low density projects with curb and gutter will require: a. Drainage area delineation and swale locations shown on the plans. b. Detail of the swale, showing minimum 5:1 side slope. C. Velocity calculations, indicating a non -erosive flow for the 10 yr storm. d. Inlet and outlet elevations. Maximum longitudinal slope is 5%. e. The type of vegetated cover specified on the plans. DEED RESTRICTIONS REQUIREMENTS The following statements must be included for all low density projects, and for all subdivisions: No more than -;6.0, 220 square feet of any lot, including that portion of the right-of-way between the edge of pavement and the front lot line, shall be covered by impervious structures, including asphalt, gravel, concrete, brick, stone, slate or similar material, not including wood decking or the water surface of swimming pools. This covenant is intended to ensure continued compliance with the stormwater permit issued by the State of North Carolina. The covenant may not be changed or deleted without the consent of the State. No one may fill in or pipe any roadside or lot -line swale, except as necessary to provide a minimum driveway crossing. For curb and gutter projects, no one may pipe, fill in, or alter any lot line swale used to meet North Carolina Stormwater Management Permit requirements. NOTE: If lot sizes vary significantly, the owner/developer must provide an attachment listing each lot number, size, and the allowable built -upon area for each lot. SI WIN �WAT ER E C E I V E MAR 151996 D E M PROJ # is SvvE a State of North Carolina Department of Environment; Health, -and Natural Resources Wiimingtori Regional Office - James B. Hunt, Jr. DIVISION OF ENVIRONMENTAL MANAGEMENT Jonathan B. Howes Governor WATER QUALITY SECTION ' "" """'" ` '°" " ' " " ""' --Secretary ""Secretary " April 8, 1996 .. Mr. John Kuske Andrew and Kuske _ - 202 North Fifth Avenue .Wilmington, North Carolina 28401 Subject: "ADDITIONAL INFORMATION Stormwater Project No. SW8 960315 _ �;��=Evstain Car New- Hanover County Dear Mr. Kuske: «.aa_�b�x_ _ , ...-a��...>o�:�..P,.:•:w �w:<=,-� The Wilmington Regional Office received a Stormmwater Management Permit Application for Evstam "!'.' Car Lot on March 15, 1996. A preliminary revie of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: 1. Please add a detail for the points where the pavement exits into the Swale which leads into the drop inlets. 2. Please note elevations along the pavement swale centerline. 3.. Please dimension the permanent pool_of the pond, the, building, -and a little more bf the - parking lot. I calculate more building and parking than you do. Please -recheck your impervious area calculation.' . L 127 Cardinal Drive Extension, Wilmington, N.C. 28405-3845 • Telephone 910-395-3900 • Fax 910-350-2004 An Eyoa1 Opportunity Affirmative Action Employer Mr. Kuske April S, 1996 Stormwater Project No. SWS 960315 �.. . r ---------------------------------------------- Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to May 8, 1996, or the application will be "R returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you have any questions concerning this matter please feel free to call me at�(910) 395-3900. 1 Sincerely, Ms. Linda Lewis Environmental Engineer DA/arl: S:IWQSISTORMWATIADDINFO1960315.APR Central Files " 2 Andrew & Kuske !CONSULTING ENGINEERS, INC. March 14, 1996 WT277a) MAR 15 1996 CATon 5 i i iilM VIVA H - R Ms. Linda Lewis, Environmental Engineer NC DEHNR-Division of Environmental Management 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Re: Evstam Car Lot New Hanover County, NC Stormwater Management Plan A&K Project NO. 95315 Dear Ms. Lewis: John R. Andrew, P.E. J. A. Kuske, RE, J. Phillip Norris, P.E. Enclosed are three sets of plans for the subject project, calculations, a stormwater maintenance schedule, the appropriate Division of Environmental Management Stormwater application, and a $385.00 check to cover the application fee. Please note that we have submitted the erosion control plan to New Hanover County for approval. Please review this information for approval and contact us with any questions or comments you may have. Thank you for your assistance on this project. Sincerely, ANDREW & KUSKE CONSULTING ENGINEERS, INC. ohn A. Kuske, III Project Engineer JAKIII:jjs enclosures cc: Jim Wenning/Wrightsville Building Corporation 953tsu. 202 North Fifth Avenue Wilmington, North Carolina 28401 Telephone: 910/343-9653 Facsimile: 910/343-9604