Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW8100201_HISTORICAL FILE_20100611
STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 07-D f DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE zC> i a o b+ 1 YYYYM M DD State Stormwater Management Systems Permit No. SW8 100201 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY COMMERCIAL DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO USMCB Camp Lejeune French Creek BEQ P-1017 & P-1047 Sneads Ferry Road, Camp Lejeune, Onslow County FOR THE construction, operation and maintenance of one (1) wet detention pond in compliance with the provisions of 15A NCAC 2H .1000 and Session Law 2008-211 (hereafter collectively referred to as the "stormwater rules') the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until June 11, 2020, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described in Section 1.8 on page 3 of this permit. The stormwater control has been designed to handle the runoff from 305,377 square feet of impervious area. 3. A 50' wide vegetative buffer must be provided adjacent impounded structures, streams, rivers and tidal waters. 4. The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans. 5. All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements. The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans. Page 2of7 State Stormwater Management Systems Permit No. SW8 100201 Q 7 The runoff from all built -upon area within the permitted drainage area(s) of this project must be directed into the permitted stormwater control system. The following design criteria have been provided in the wet detention pond and must be maintained at design condition: a. Drainage Area, acres: Onsite, ft : Offsite, ft2: b. Total Impervious Surfaces, ft2: Onsite, ft : Offsite, ft2: C. Design Storm, inches: d. Average Pond Design Depth, feet: e. TSS removal efficiency: f. Permanent Pool Elevation, FMSY g. Permanent Pool Surface Are4, ft h. Permitted Storage Volume, ft': i. Temporary Storage Elevation, FMSL: j. Pre-dev. 1 yr-24 hr. discharge rate, cfs: k. Controlling Orifice: I. Orifice flowrate, cfs: M. Permitted Forebay Volume, ft3: n. Fountain Horsepower o. Receiving Stream/River Basin: P. Stream Index Number: q. Classification of Water Body: II. SCHEDULE OF COMPLIANCE 12.52 545,294 None 305,377 305,377 None 1.5 5.0 90% 15.2 27,880 39,423 16.2 15.67 3.5"O pipe 0.18 25,224 113 Cogdels Creek 1 White Oak 19-23 "SC; NSW" 1. The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface. 2. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 3. The permittee shall at all time provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowin.9 and re -vegetation of slopes and the vegetated filter. d. Immediate repair of eroded areas. e. Maintenance of all slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of outlet structure, orifice device, flow spreader, catch basins and piping. g. Access to the outlet structure must be available at all times. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. Page 3 of 7 State Stormwater Management Systems Permit No. SW8 100201 5. Decorative spray fountains will be allowed in the stormwater treatment system, subject to the following criteria: a. The fountain must draw its water from less than 2' below the permanent pool surface. b. Separated units, where the nozzle, pump and intake are connected by tubing, may be used only if they draw water from the surface in the deepest part of the pond. c. The falling water from the fountain must be centered in the pond, away from the shoreline. d. The maximum horsepower for a fountain in this pond is 113 horsepower. 6. The facilities shall be constructed as shown on the approved plans. This permit shall become void unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 7. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, -a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. A modification may be required for those deviations. 8. If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. 9. Access to the stormwater facilities for inspection and maintenance shall be maintained via appropriate recorded easements at all times. 10. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: a. Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area or to the drainage area. e. Further development, subdivision, acquisition, lease or sale of any, all or part of the project area. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. 11. Prior to the construction of any permitted future areas shown on the approved plans, the permittee shall submit final site layout and grading plans to the Division for approval. 12. A copy of the approved plans and specifications shall be maintained on file by the Permittee at all times. 13. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. Page 4 of 7 State Stormwater Management Systems Permit No. SW8 100201 III. GENERAL CONDITIONS This permit is not transferable to any person or entity except after notice to and approval by the Director. At least 30 days prior to a change of ownership, or a name change of the permittee or of the project, or a mailing address change, the permittee must submit a completed and signed Name/Ownership Change Form to the Division of Water Quality, accompanied by the supporting documentation as listed on the form. The approval of this request will be considered on its merits and may or may not be approved. 2. The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request. Neither the sale of the project nor the conveyance of common area to a third party constitutes an approved transfer of the stormwater permit. 3. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 4. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal) having jurisdiction. 5. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 6. The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility. 7. The permit remains in force and effect until modified, revoked, terminated or renewed. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and re - issuance or termination does not stay any permit condition. 8. Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. 9. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 10. The permittee shall submit a permit renewal request at least 180 days prior to the expiration date of this permit. The renewal request must include the appropriate documentation and the processing fee. Permit issued this the 11th day of June, 2010. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Al for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Page 5 of 7 State Stormwater Management Systems Permit No. SW8 100201 French Creek BEQ P-1017 & P-1047 Stormwater Permit No. SW8 100201 Onslow County Designer's Certification I, , as a duly registered in the State of North Carolina, having been authorized to observe (periodically/ weekly/ full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form is included in the Certification. Noted deviations from approved plans and specifications: Signature Registration Number Date SEAL Page 6 of 7 State Stormwater Management Systems Permit No. SW8 100201 Certification Requirements: 1. The drainage area to the system contains approximately the permitted acreage. 2. The drainage area to the system contains no more than the permitted amount of built -upon area. 3. All the built -upon area associated with the project is graded such that the runoff drains to the system. 4. All roof drains are located such that the runoff is directed into the system. 5. The outlet structure elevations are per the approved plan. 6. The outlet structure is located per the approved plans. 7. Trash rack is provided on the outlet structure. 8. All slopes are grassed with permanent vegetation. 9. Vegetated slopes are no steeper than 3:1. _10. The inlets are located per the approved plans and do not cause short- circuiting of the system. .11. The permitted amounts of surface area and/or volume have been provided. .12. Required drawdown devices are correctly sized and located per the approved plans. .13. All required design depths are provided. _14. All required parts of the system are provided, such as a vegetated shelf, and a forebay. _15. The required system dimensions are provided per the approved plans. _16. All components of the stormwater BMP are located in either recorded common areas, or recorded easements. cc: NCDENR-DWQ Regional Office Onslow County Building Inspections Page 7 of 7 MEMORY TRANSMISSION REPORT FILE NO. 223 DATE 06.11 11:51 TO g 919104512927 DOCUMENT PAGES S START TIME 11:51 END TIME 11 1:52 PAGES SENT 0 \ STATUS -J D050 TIME :06-11-'10 11:52 FAX NO.1 :910-350-2018 NAME :DENR Wilmington TX FAILURE NOTICE** Stale of North Carotlaa >Dnpw r�w+ent of Eovkr+onment and Naturak Rcnou rcea W I{�{AgtOR ReQioA A{ QTca IRaviri(fr Rwwaw Paa'flpa. Govaraor FA7G GpVER STET Urr Fra.eswow. Sa-crctary Phone: (910179d-733d 127 Car6knal 17riv Ex[emaian, W ilminston, NC " &4t a <910) 79Fr721 7 o M P_q1 f_lpporronity AM7 rlv / Iir Lmp'�oyer State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Beverly Eaves Perdue, Governor FAX COVER SHEET Dee Freeman, Secretary Date Co: G�/� P G- E✓� Ey� �' /mil �-� Fax: Re: No. Pages (excl. cover): From: Jo Casrner Phone: (910) 796-7336 Fax: 910 350-2004 127 Cardinal Drive Extension, Wilmington, NC 28405 0 (M) 746-7215 o An Equal Opportunity Affirmative Action Emp lover Permit Number SW8100201 Program Category State SW Permit Type State Stormwater Primary Reviewer chris.baker Coastal SW Rule Coastal Stormwater - 2008 Permitted Flow Facility Name French Creek BEQ P1017 and P1047 Location Address Sneads Ferry Rd Camp Lejeune NC 28547 Central Files: APS SWP 06/11/10 Permit Tracking Slip Status Project Type Active New Project Version Permit Classification 1.00 Individual Permit Contact Affiliation Major/Minor Region Minor Wilmington County Onslow Facility Contact Affiliation Owner Name Owner Type Commanding Officer US Marine Corps - Camp Lejeune Government - Federal Owner Affiliation Carl H. Baker Psc Box 20004 Camp Lejeune NC 285420004 Dates/Events Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 06/11/10 06/03/10 06/11/10 06/11/10 06/11/20 Regulated Activities Requested/Received Events State Stormwater - HD - Detention Pond Deed restriction requested Deed restriction received Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin WET DETENTION POND ANALYSIS - ALL RULES FILE NAME: S:IWQSISTORMWATERIEXCELSPREADSHEETSIPONDI100201 PROJECT #: SW8 100201 REVIEWER: C. Baker Initial Run Date 06/1012010 PROJECT NAME: French Creek BEQ P1017 & P1047 Last modified 10-Jun-10 Receiving Stream: Cogdels Creek Class: Sc;Nsw Drainage Basin: While Oak Within 112 mile SA? In Y or N Index No. 19-23 Site Area 12.66 acres OO Drainage Area 545294.00 square feet DA Area 12.52 acres Rules- "2008" or "Ph2" 2008 IMPERVIOUS AREAS - BUA Runoff C Buildings 50938.00 square feet 1 user inpu Street 49495.00 square feet 0.98 formula Parking 184475.00 square feet 0.99 SW 10128.00 square feet 0.95 Other 10341,00 square feet 0.98 Furture square feet BUA at dill. DS® square feet TOTAL F 305377.00 square feet SURFACE AREA CALCULATION (wills added DA and BUA at different design storm) Overall % Impervious F 56.00% SA/DA Ratio 3.98% Average Design Depth 5 feet Req. SA 21704 sf TSS, 85 or 90: 90 % Prov. SA 27880 sf TEMPORARY POOL AND FOREBAY VOLUME CALCULATIONS New BUA Old BUA Drainage AreaO 545294.00 sf BUA 305377.00 0.00 sf Post development Rv= 0.554 #DIVIG! unitless Old BUA Design Storm inches Old BUA Design Volume 0 1.5" New BUA Design Storm Volume 37763 1 yr. 24 hour precipitation depth (inches) from NOAA chart Predevelopment Rv value Use 0.05 if no existing 8UA 1 yr. 24 hr. Pre -development volume 0 cubic feet 1 yr, 24 hr, Post -development volume 0 cubic feet 2D08 Design Volume 37763 cubic feet Phase 2 Design Volume 37763 cubic feet Required Volume 37763 cf Area, sf Inc. volume Acc. volume Top of Sediment 9.00 msl ......... 14985.00 0.00 0.00 Bottom of Shelf 14.70 msl.......... 24694.00 113085.15 113085.15 Permanent Pool 15.20 msl......... 27880.00 13143.50 126228.65 Top of Shelf 15.70 msl.......... 42746.00 17656.50 143885.15 Temporary Pool 16.20 msl......... 44325.00 21767.75 165652.90 Volume met at elev 16.16 Imsl FOREBAY Vol. Prov. at TP 39424.25 cf Perm. Pool Volume= 126229 Req. Forebay Volume= 25246 Provided Volume= 25224.00 Percent= 20.0% Calculated Averatie Depth, feet 15.05 Max Pumo HP 1/2 ORIFICE CALCULATION Average Head Flow 02, cfs Flow 05, cfs No. of Orifices Diameter, inches Drawdown = 1 yr 24 hr intensity, in/hr Runoff Coefficient 1 yr 24 hr peak 4 Orifice flow<1yr24hr? feet Q2 Area = 12.25 cfs Q5 Area = 4.90 CIS Orifice Area = 9.62 Avg, Flow Q= 0,172 or weir H x W in x days '# of end contractions, N = NOAA chart @i discharge coefficient, C unitless Effective weir length, L = cfs sq. inches sq. inches sq. inches cfs in OAO 0.28 0.219 0.087 1 3.50 2.5 0.16 0.66 1.32 YES -OK COMMENTS Surface Area , Volume and Orifice are within Design Guidelines. i °Date'' Number Archer Western RQ'Joint Venture *' �, ' : r o4��412oia 2751 1 929 W Adams St t Private Sank : 02 64$ b 3 ,Chicago, IL 60607 Chicago iL 60602 US 7.10 . r (312} 563 5400 $ : ******4,000:00 =.2 :PAY A: t Votd After 90,Days FOUR THOUSAND DOLLARS 01100 � i C N+ X f i 1 Ali •� 1rV $ k' I i w,�y,! .,,c�, nki, "by �LT"••y- f �w; [Ir ~ � P���M1�m'�14�s .7 TO 7h1 'NCDENRI©WQ d� y,. �� y r �.,..��P���pY ram; ORQERI' 2 OF .a 9�r. fi .. .,�� �eCE1� eA�kr� n�No 'in 00275L11' :❑710064861: 2203L4Lu■ STORMWATER MANAGEMENT CALCULATIONS For FY09 FRENCH CREEK BEQ P-1017 P-1047 PREPARED FOR Deputy Public Works Officer Bld 1005 Michael Road MCB Camp Lejeune 28547 Prepared by: COASTAL SITE DESIGN, PC PO Box 4041 Wilmington, NC 28406 Phone: 910 791-4441 Fax: 910 791-1501 License C-271D 1����}'... ��;271 'Howard Resrflk, P.E. JUN 3 Z010 COASTAL SITE DESIGN, PC PO Box 4041 Wilmington, NC 28406 Phone: 910 791-4441 Fax: 910 791-1501 FOR STORMWATER EXPRESS REVIEW June 2010 PROJECT NAME: FY09 French Creek P-1017 P-1047 MCB Camp Lejeune, NC Onslow County PROJECT DESCRIPTION: The project area for this development is 12.66 acres with 27 acres of disturbance. There are no wetlands within the project limits. This project is for the construction of three BEQ buildings, parking lot and recreation courts. The owner is the United States Marine Corps. Water and sewer utilities will be provided by the BASE. Stormwater from the site will drain to SC, NSW waters located in the White Oak River Basin (Index # 19-23). This project is subject to Coastal Stormwater Regulations. The project will be high density utilizing underground conveyance pipe and open channels to discharge stormwater into a wet basin designed for 90% TSS removal. All proposed impervious inside the project limits will be collected. Proposed impervious for the site is 55%. There are no buffer requirements for the development. No offsite runoff will be entering the site. The site will have access to Sneads Ferry Road from an existing road that runs into the site. ECS performed SHWT determinations for the site and their findings were utilized to design the pond. PROJECT BMP: high density/ wet basin. STORMWATER ENGINEER/CONSULTANT: Coastal Site Design, PC PO Box 4041 Wilmington, NC 28406 Rodney Wright rodney@coastalsitedesign.com 910 7914441 office 910 791 1501 fax JUN 0 S 2010 BY PROJECT DATA: Existing Site Data (areas within property boundary): wetland area 0.00 sf (0.00 acres) upland area 551,752 sf (12.66 acres) Total site area 551,752 sf (12.66 acres) Proposed Site Data: Proposed Building 50,938 sf (1.17 acres) Proposed asphalt/curb and gutter 184,475 sf (4.23 acres) sidewalks 10,128 sf (0.23 acres) Fire access road 49,495 sf (1.14 acres) Recreation 10,341 sf (0.24 acres) Total proposed impervious area 3059377 sf (7.01 acres) Soil Tomes: Abbreviation Type and Description Hydrologic Group Area Bab Baymeade A 12.66 ac (See,attached soils map and pages 132-134 of Table 15, "Physical and Chemical Properties of the Soils") POND CALCULATIONS Pre-dev. Value of Runoff Coefficient (c) for Rational Formula = 0.20 Area = 545,294 sf or 12.52 acres Qmax for pre-dev 1-yr storm = 15.67 cfs Post Dev Value of Runoff Coefficient (c) for Rational Formula = 0.54 Area = 545,294 sf or 12.52 acres ((305,377 x 0.95) + (239,917 x 0.20))1545,294 = 0.620 or 0.62 Qmax for post-dev 1-yr storm = 48.59 cfs Routed site — areas draining to pond routed through pond (see hydrograph summary & reports): Qmax for post route 1-yr storm = 0.16 cfs Summary: Qmax for routed post dev 1-yr/24-hr storm = 0.16 efs < 15.67 cfs.... O.K. i�v c JUN U 9 2U10 WET DETENTION BASIN CALCULATIONS FRENCH CREEK BEO POND DETERMINE IMPERVIOUS PERCENTAGE area to basin = 545,294 sf 12.52 acres buildings = 50,938 .sf 1.17 acres paved area = 184,475 sf 4.23 acres sidewalks= 10,128 sf 0.23 acres recrecational = 10.341 sf 0.24 acres fire mad = 49,495 sf 1.14 acres total impervious surface = 305,377 sf 7.01 acres total non -impervious surface = 239,917 sf 5.51 acres percent imp. = 56.0 % DETERMINE REQUIRED SURFACE AREA from 90 % TSS Removal Chart: @ depth = 5 ft imp % SAlDA 50 3.5 56.0 x 60 4.3 x = 3.98 minimum surface area = 0.0398 x 545,294 sf = 21,704 sf surface area provided = 27,880 sf @ elevation 15.2 1.5" VOLUME DETERMINATION: DETERMINE RUNOFF COEFFICIENT (Rv) I = 56.0 percent impervious Rv = ? (runoff coefficient, inches per inch) Rv= 0.05 + 0.009 (1) Rv = 0.55 inlin DETERMINE VOLUME design storm = 1.5 inch Rv= 0,55 infin drainage area = 12.52 acres volume = ? volume = (design storm)(Rv)(drainage area) volume = 0.9 acre-ft volume = 37,763 cf of required storage volume BY COASTAL SITE DESIGN, PC PO BOX 4041 WILMINGTON, NC 28406 WET DETENTION BASIN STAGE -STORAGE TABLE: INCREMENTAL ELEVATION AREA VOLUME STORAGE (FT) (SF) (cf) (cf) 1 4,985 10 16, 6 15.771 11 18,183 17,370 12 19,866 19,025 13 21,606 20,736 14 23,403 22,5C5 Bottom Shelf 14.7 24,694 16,834 15 26,587 7,692 PP 15.2 27,880 5,447 - Top Shelf 15.7 42,746 17,657 17,657 16 43,687 12,965 30,621 State Storage 16.2 44,325 8,801 39,423 17 46,875 45,600 85,023 volume at permanent pool (elev. 15.2) = 125,378 cf 1.5" storage volume provided (alev. 16.2) - 39,423 cf total volume of basin = 210,400 cf surface area at bottom of 10:1 shelf ( 14.7) = 24,694 sf volume at bottom of 10:1 shelf = 112,239 cf surface area at top of 10:1 shelf (15.7) = 42,746 sf volume at top of 10:1 shelf = 143,034 cf minimum forebay volume = 25,076 cf AVERAGE POND DEPTH AREA BOTTOM SHELF (ABS) = 24,694 SF AREA PP (APP) = 27,880 SF AREA BOTTOM POND (ABP) = 14,985 SF DEPTH = 14.7 -9 = 5.7 ft (0.25 X (1 + (ABSIAPP)))+(((ABS+ABP)12) X (DEPTHIABS)) AVERAGE DEPTH = 5.05 FOREBAY 1 STAGE -STORAGE TABLE: INCREMENTAL ELEVATION AREA VOLUME STORAGE (FT) (SF) (cf) (cf) 11 1,635 12 2.160 1.898 1,898 13 2.742 2.451 4.349 14 3.380 3.061 7,410 15 4.594 3.987 11.397 15.2 6,116 4,855 16.252 forebay volume provided = 16,252 cf FOREBAY 2 STAGE -STORAGE TABLE: INCREMENTAL ELEVATION AREA VOLUME STORAGE (FT) (SF) (cf) (cf) 11 693 12 1,026 860 860 13 1,416 1,221 2.081 14 1,862 1,639 3,720 15 2,750 2,306 6,026 15.2 3,143 2,947 8,972 forebay volume provided - 8,972 cf 1 `'.1 1-1 ram' 3UN i) 3 2010 COASTAL SITE DES{GN, PC PO BOX 4041 WILMINGTON, NC 28406 STAGE - DISCHARGE TABLE: size of orifice (In) = 3.50 crest length of we r cut (ft) = 0.00 crest length of grates (so = 4.0 crest length of spillway (ft) = 20.0 ELEVATION 3.5' PVC WEIR (ft) (cfs) (cfs) 15.2 0.00 16 0.29 no weir cut 16.2 0.32 no weir cut 17 0.43 no weir cut PVC DRAW DOWN Orifice size = 3.50 in Normal Pool Storage Elev. = 15.2 1.5" storage Elev. = 16.2 elevation of orifice = 15.2 elevation of weir cut = 0.0 elevation of grates = 16.2 elevation of spillway = 16.5 GRATES SPILLWAY TOTAL (cfs) (cfs) (cfs) - 0.29 0.00 0.32 9.45 21.21 31.09 Orifice coefficient (C) = 0.6 Average head from 1.5' storage to orifice (h) = (16.2 - 15.2) t3 = 0.33 ft Orifice cross sectional area (A) = pi x r12 = 3.14 x (d12)^2 = 0.06678 sf Acceleration due 10 gravity (g) = 32.2 ftls^2 C=CA (2gh)^1;2 = 0.6 x 0.06678 x (2x32.2x0.33)^112 = 0.18564 cfs 39.423 t 0.18564 = 212,358 seconds = 2.46 nays I sins o � za3o �J - I, - COASTAL SITE DESIGN, PC PO 90X 4041 WILMINGTON, NC 28406 Hydrograph Summary Report HydraflowHydrographsbylntelisolvev9.1 Hyd. No. Hydrograph type (origin) Peak flow (cfs) Time interval (min) Time to peak (min) Hyd. volume (cult) Inflow hyd(s) Maximum elevation (ft) Total strge used (cult) Hydrograph description 1 Rational 15.67 1 5 4,702 -- - Pre Dev 2 Rational 48.59 1 5 14,576 — Post Dev 3 Reservoir 0.158 1 10 11,389 2 15.61 14,530 Routed . 1741-4 � l JUN o 3 20to BY BEQ_site.gpw Return Period: 1 Year Wednesday, Jun 2, 2010 Hydrograph Report Hydraflow Hydrographs by lntelisolve v9.1 Wednesday, Jun 2, 2010 Hyd. No. 1 Pre_Dev Hydrograph type = Rational Peak discharge = 15.67 cfs Storm frequency = 1 yrs Time to peak = 5 min Time interval = 1 min Hyd. volume = 4,702 cult Drainage area = 12.520 ac Runoff coeff. = 0.2 Intensity = 6.259 inlhr Tc by User = 5.00 min OF Curve = wilmington_2008.IDF Asc/Rec limb fact = 111 Q (cfs) 18.00 15.00 12.00 "I 3.00 0.00 Y ' 0 1 — Hyd No. 1 Pre_Dev Hyd. No. 1 — 1 Year 2 3 4 5 6 Q (cfs) 18.00 15.00 12.00 M M 3.00 _ 'M 0.00 7 8 9 10 Time (min) JUN 032010 Hydrograph Report HydraFlow Hydrographs by Intelisolve v9.1 Wednesday, Jun 2, 2010 Hyd. No. 2 Post_Dev Hydrograph type = Rational Peak discharge = 48.59 cfs Storm frequency = 1 yrs Time to peak = 5 min Time interval = 1 min Hyd. volume = 14,576 cult Drainage area = 12.520 ac .:., Runoff coeff. = 0.62* Intensity = 6.259 inlhr Tc by User = 5.00 min OF Curve = wilmington_2008.IDF Asc/Rec limb fact = 111 Composite (Area/C) = [(7.010 x 0 95) + (5.510 x 0.20)] 112.520 0 (cfs) 50.00 40.00 30.00 10.00 0.00 -�-- --�� 0 1 �---- Hyd No. 2 Post Deg Hyd. No. 2 -- 1 Year 2 3 4 5 6 7 8 9 'JINN 0 3 2010 i Q (cfs) 50.00 40.00 30.00 20.00 10.00 -N- 0.00 10 Time (min) Hydrograph Report Hydraflow Hydrographs by lntelisolve v9.1 Hyd. No. 3 Routed Hydrograph type = Reservoir Storm frequency = 1 yrs Time interval - = 1 min Inflow hyd. No. = 2 - Post _Dev Reservoir name = BEQ Pond Storage Indication method used. Q (cfs) 50.00 40.00 10.00 0.00 `- 0 300 — Hyd No. 3 Peals discharge Time to peak Hyd. volume Max. Elevation Max. Storage Routed Hyd. No. 3 — 1 Year Wednesday, Jun 2, 2010 = 0.158 cfs = 10 min = 11,389 cult = 15.61 ft = 14,530 cult 600 900 1200 1500 1800 2100 2400 2700 Hyd No. 2 "FIE71—t Total storage used = 14,530 tuft JUN 0 3 2010 13Y: Q (cfs) 50.00 40.00 30.00 20.00 10.00 1 0.00 3000 Time (min) Pond Report Hydraflow Hydrographs by Intelisolve Al Pond No. 1 - BEQ Pond Pond Data Contours - User -defined contour areas. Conic method used for volume calculation. Begining Elevation = 15.20 ft Stage 1 Storage Table Stage (ft) Elevation (ft) Contour area (sgft) Incr. Storage (cult) Total storage (cult) 0.00 15.20 27,880 0 0 0.80 16,00 43,687 28,388 28,388 1.00 16.20 44,325 8,800 37,189 1.80 17.00 46,875 36,472 73,660 Wednesday, Jun 2, 2010 Culvert 1 Orifice Structures Weir Structures [A] [B] [C] [PrfRsr] [A] [B] [C] ID] Rise (in) = 18.00 3.50 0.00 0.00 Crest Len (ft) = 4.00 20.00 0,00 0.00 Span (in) = 18.00 3.50 0.00 0.00 Crest El. (ft) = 16.20 16.50 0.00 0.00 No. Barrels = 1 1 0 4 Weir Coeff. = 3.33 2.60 2.60 3.33 Invert El. (ft) = 15.20 15.20 0.00 0.00 Weir Type = Riser Broad Broad -- Length (ft) = 39.00 1.00 0.00 0.00 Multi -Stage = Yes Yes No No Slope (%) = 0.50 0.00 0.00 nla N-Value = .013 .013 .013 n1a Orifice Coeff. = 0.60 0.60 0.60 0,60 Exfll.(inlhr) = 0,000 (by Contour) Multi -Stage = nla Yes No No TW Elev. (ft) = 0.00 Stage (ft) 2.04 1.80 1.60 1.40 1.20 1.00 0,80 0.64 0.40 0.24 0 00 Note: CulvertfOririce outflows are analyzed under inlet {ic) and outlet (oc) control. Weir risers checked for orifice conditions (ic) and submergence (s). Stage 1 Discharge Elev (ft) 17.20 17.00 16.80 16.60 16.40 16.20 16.00 15.80 15.60 15.40 15.20 0.00 1.00 2.00 3.00 4,00 5.00 6.00 7.00 Total Q Discharge (cfs) �.� JUN 0 3 2010 PY: i TM E C S C A R O L I N A S, L L P "seffing the Standard for Service" GAROLINas Geotechnical - Construction Materials • Environmental • Facilities April 28, 2010 Mr. Aaron Edksson RQ Construction Inc. 3194 Lionshead Avenue Carlsbad, California 92010 Reference: Report of Seasonal High Water Table Estimation French Creek BEQ P-1017-1047 Camp Lejeune, Onslow County, North Carolina ECS Project No. 22.18763B Dear Mr. Eriksson: ECS Carolinas, LLP (ECS) recently conducted an estimation of the Seasonal High Water Table (SHWT) for the proposed stormwater best management practice (BMP) areas at the proposed 1=rench Creek BEQ P-1017-1047 on Camp Lejeune, Onslow County, North Carolina. This letter, with attachments, is the report of our estimation. Field Testing On April 21, 2010 ECS conducted an exploration of the subsurface soil and groundwater conditions at four requested locations shown on the attached Boring Location Plan (Figure 1). The purpose of this exploration was to estimate the depth of the SHWT of the in -place soils for the proposed stormwater BMP areas. The locations were surveyed prior to ECS's visit. ECS explored the subsurface soil and groundwater conditions by advancing one hand auger boring into the existing ground surface at the requested boring locations. ECS visually classified the subsurface soils and obtained representative samples of each soil type encountered. ECS recorded the SHWT and groundwater level observed at the time of each hand auger boring. The attached SHWT sheet provides a summary of the subsurface conditions encountered at each hand auger boring location. The area in which boring locations 1 and 2 were located had been cut approximately four feet below the former existing grade elevation. ECS advanced one additional boring (#3) adjacent to boring number one in the natural grade elevation. 1 .SUN 0 3 2010 7211 Ogden Business Park, Suite 201, Wilmington, NC 28411 • T: 910-68"114 • F: 910-686-9666 • www.ecsiimited.com ECS Carollnas, LLP • ECS Florida, LLC • ECS lAlnols, LLC • ECS Mild-Atlanttc, LLC • ECS Southeast, LLC ECS Texas, LLP Report of SHWT Estimation French Creek BEQ P-1017-1047 Camp Lejeune, Onslow County, North Carolina ECS Project No. 22.15763E April28, 2010 The groundwater level and the SHWT were estimated at each boring location below the existing grade elevation. Below is 'a summary of each boring location. Location Water Level SHWT 1 10 inches 0 inches 2 8 inches 0 inches 3 38 inches 24 inches 4 60 inches 42 inches 5 40 inches 30 inches The SHWT may vary within the proposed site due to changes in subsurface conditions and elevation. Closure The activities and evaluative approaches used in this assessment are consistent with those normally employed in assessments of this type. Our evaluation of site conditions has been based on our understanding of the project information and the data obtained during our field activities. ECS appreciates the opportunity to provide our services to you on this project. If you have any questions concerning this report or this project, please contact us at (910) 686-9114. Respectfully, ECS CAROLINAS, LLP K. Brooks Wall Project Manager Walid M. Sobh, P.E. Principal Engineer CC: Ryan Littleton — Calibre Engineering; Rodney Wright — Coastal Site Design, PLLC Attachments: Boring Location Plan SHWT sheet C 5 v �ai.� 2 JUN 0 3 2010 E-"Y- U APPROXIMATE BORING LOCATIONS French Creek Site Figure 1— Boring Location Plan Camp Lejeune, Onslow Co., NC Provided by: Calibre Engineering ECS Project No. 22-15763B April 21, 2010 KBW I JUN 0 3 2010 rJ Y Season High Water Table Estimation French Creek BEQ P-1017-1047 Camp Lejeune, Onslow Co., North Carolina ECS Project No. 22.1576313 April 21, 2010 Location Depth Soil Description 1 0-24" Tan/gray fine SAND Seasonal High Water Table was estimated to be at 0 inches below the existing grade elevation. Groundwater was encountered at 10 inches below the existing grade elevation. Location Depth Soil Description 2 0-24" Tan/gray fine SAND Seasonal High Water Table was estimated to be at 0 inches below the existing grade elevation. Groundwater was encountered at 8 inches below the existing grade elevation. Location Depth Soil Description 3 0-48" Tan/gray fine SAND Seasonal High Water Table was estimated to be at 24 inches below the existing grade elevation. Groundwater was encountered at 38 inches below the existing grade elevation. Location Depth Soil Description 4 0-181, Gray fine SAND 18"-60" Tan/orange fine SAND Seasonal High Water Table was estimated to be at 42 inches below the existing grade elevation. Groundwater was encountered at 60 inches below the existing grade elevation. JUN 0 3 2010 Season High Water Table Estimation French Creek BEQ P-1017-1047 Camp Lejeune, 4nslow Co., North Carolina ECS Project No. 22.15763B April 21, 2010 Location Depth Soil Description 5 0-18" Gray silty SAND 18"-30n Gray fine SAND 30"-40" Hard Pan 40"-60" Tan/gray fine SAND Seasonal High Water Table was estimated to be at 30 inches below the existing grade elevation. Groundwater was encountered at 40 inches below the existing grade elevation. JUN 0 3 2010 BY: Name of Stream Description Curr. Class Date Basin Stream Index # Southwest Creek From Mill Run to New C;HQW,NSW 08/01/91 White Oak 19-17-(6.5) River Catherine Lake From Catherine Lake to C;NSW 08/01/91 White Oak 19-17-1 Creek Southeast Creek Catherine Lake Entire Lake B;NSW 09/01/91 White Oak 19-17-1-1 Deep Run From source to C;NSW 08/01/91 White Oak 19-17-2 Southwest Creek Harris Creek From source to C;NSW 08/01/91 White Oak 19-17-3 Southwest Creek Haws Run From source to C;NSW 08/01/91 White Oak 19-17-4 Southwest Creek Tank Creek From source to C;NSW 08/01/91 White Oak 19-17-5 Southwest Creek Hicks Run From source to C;NSW 08/01/91 white Oak 19-17-6 (Hickory Run) Southwest Creek Mill Run From source to SC;NSW 08/01/91 White Oak 19-17-7 Southwest Creek Morgan Bay Entire Bay SC;NSW 08/01/91 White Oak 19-18 Lewis Creek From source to New SC;HQW,NSW 08/01/91 White Oak 19-19 River Cow£ord Branch From source to New C;NSW 08/01/91 White Oak 19-2 River Wallace Creek From source to New SB;NSW 08/01/91 white Oak 19-20 River Bearhead Creek From source to Wallace SB;NSW 08/01/91 white Oak 19-20-1 Creek Beaverdam Creek From source to Wallace SB;NSW 0B/01/91 white Oak 19-20-2 Creek Town Creek From source to New SC;HQW,NSW 08/01/91 White Oak 19-21 River Farnell Bay Entire Bay SC;NSW 08/01/91 White Oak 19-22 ,Cogde ram source to New SC;NSW 08/Cl/91 White Oak 19-23 n�Ci"eekj',,. River Frenchs Creek From source to New SC;NSW 08/01/51 White Oak 19-24 River Jumping Run From source to Frenchs SC;NSW 09/01/91 White Oak 19-24-1 Creek Cowhead Creek' From source to Frenchs SC;NSW 08/01/91 white Oak 19-24-2 Creek Duck Creek From source to New SC;NSW 08/01/31 White Oak 19-25 River Whitehurst Creek From source to New SC;BQW,NSW 06/01/91 white Oak 19-26 River Goose Creek From source to New SC;HQW 08/01/90 White Oak 19-28 River Two Pole Branch From source to New SC;HQW 08/01/90 White Oak 19-29 River Squires Run From source to New C;NSW 08/01/91 white Oak 19-3 River Mill Swamp From source to Squires C;NSW 08/61/91 White Oak 19-3-1 Run Page 4 of 11 2009-08-15 07:12:25 JUN 6 3 2M 1 u f aa! I CAMP LEJEUNE, N. C. l 34077—F3-TF-C24 • s ti v 2s — 1952 } PHOTOREVISED 197L DMA 5553 III NE—SERIF-SV942 ?±_ a ' X28 47, - oa- zz N 6 4 t-- � - � •.-�:. _ :�". :,, ere k ec�d= eg"T - T � I \Chive -in i S I i • Theate MWA 11, ,JUN o 3 2010 BY: T-AP- tl 1 � _ •,t 1\ ) Zh 1 •� I� d� r — POINT PRECIPITATION,`" FREQUENCY ESTIMATES FROM NOAA ATLAS 14 WMMINGTON WSO AIRPORT, NORTH�CAROLINA (31-9457) 34.2683 N 77.9061 W 26 feet from ?feciPMt!len-Fregn=ey Atlas ofthe United States" NOAA Atlas I4, Volume 2, Version 3 . GM Bonain, D, lt3artisr, B.1-th, T. ]?�zybok, M.Ye1aa, and D. Rrley ' NOAA. National weather service, S&rrSpring. Maryland, 2004 Eructed: Mon Feb 4 2008 :. Go �i�er%ce"�5mits' eas �a'fy ocatio`n M s � fJae Iafn: G!5"data�,�„a '�elp. , D�cs , '� a Preelpita'don luteli!tp ]Es-dmtes (i?i/i3i') {years) min F�L;]min min min. min 3 iIr R hr hr hr day d vv da aEl l _a 162b 5.G0' .16 2.86 1.78 1.05 0.75 0.47 027 0.16 0.09 0.D5 0.04 0.03 0.02 0.02 0.01 0.01 �rr�, 7.42 5.93 4.97 3.44 2.15 128 0.91 0:55 033 ' 0.19 0.11 0.06 0.04 ] 0.03 0.02 002 OA2 0.01 18.70 6.97 5.88 4.17 2.67 1.63 1.17 0.72. 0.42 0 25 0.15 D.08. O.05 0.04 4.43 0.02 0.02 0.02 10 9.70 7.76 6.54 4.74 3.08 1.93 139 0.87 0.51 03D 0.17 0.10 OF067 0.05 0.03 DA2 Cf.02 0.02 LJ 10.9b 8.74 738 5.47 3.b4 2.36 1.72 1.08 0.64 O 38 0 22 0.12 0.08 0.06 0.04 0.03 0.02 0,02 50 11.40 9.48 8.00 6.43 .08 2 74 026 2 1 d.75 0.45 426 0.14 0.09 0.07 0.04 0.03 0.03 0. 02 100 12.89 1024 8.53 5.61 55 3.15 35 1.48 0.89 0.53 4.30 O.I6 O.iO 0.07 0.05 0.04 0.43 0.02 200 13:85 10.97 923 7.i9 S.O4 3.60 72 1.71 1,04 0.61 0.35 0.18 0.11 d_48 4.05 0.04 0.03 0.03 500 15.10 I1.94 10A2 7.97 5.72 27 28 2 0$ 127 D.75 0.42 022 0.13 O.IO 0.06 D.04 0.03 0.03 1000 I6.12 12.58 10.62 B.SD 627 4.$5 3.77 .40 1.47 0.87 0.48 0.25 0.15 0.11 0.07 O.DS O.D4 0.03 These pra*tafion frequency esllmales me based an a oardal duration serlees ARI L-the Average Reamente Udxrval. Please rpiarth the dmzmtadon for more Informadon HOTE'romra<drtg inrc� esdmu3tes nearzero to appearas zero. *Upper bound of the 90% confidence interval Precipitation Intensity Estimates (m/hr) 19 (Years) min min 71�min Fm- min71rhr Iu hr daY day day dzy �Y [JIET724F748�j�� L�_ A� 6.73 5.3 7 4.4E 3.D7 1:91 1.I5 0.82 0.51 0.30 0.18 0.10 0.06 0.04 0.03 0.02 0.02 0.01 0.01 7.97 L� 637 5 34. 3.69 2.31 139 0.99 0.62 0.36 422 0.13 0.07 0.05 O.D4 0.02 0.02 0.02 D.OI �` I 19.32 7.46 6.30 .47 2.87 1.78 Z27 O.79 0.4E 0.28 0.16 EE 0.06 0.04 0.03 OA2 0.02 0.02 10 I039 832 7.DI S.DB 331 2.10 1.51 0.94 0.55 033 0.19 4.11 0.07 O.OS 0.03 D.63 0.02 0.02 11.72 934 7.89 5.84 3.89. 257 I.87 I.17 0.69 0.42 024 07137 0.08 Q.O6 0.04 0.03 0.02 0.42 50 i2.74 10.15 8.56 6.45 4.37 2.98 2-19 1.37 d.82 O 50 O28 0.15 0.10 0.07 d.04 0.03 0:03 0.02 100 13.79 1096 923 7.07 4.87 3.42 .54' i.60 0.96 058 033 O.I8 0.11 0.08 0.05 0.04 0.03 0.03 200 14.84 11.76 9.89 7.70 5.4D 3.9D 2.93 1.85 1.I2 0.68 039 0.20 0.12 0.49 4.06 0.04 0.03 0.03 500 I6.22 12.83 I0.77 8.57 6.14 3.54 225 138 0.84 0.47 0.24 0.15 O.I1 0.07 0.05 O.D4 0.03 1000 17.33 13.64 11.42 9.24 6.75 529 .OS 2.60 1.6D 098 O.SS 4.28 4.17 0.12 0.67 D.OS 0.04 0.03 The upper bound of the confidence interval et 9Q% confidence level is the value which 5% cf the simulated quan@e values for a given frequency are greater 4ian. eThme.precip Won frequency esfnatss am based on a appal duradgy selLe56 AR I is ft Average Recurrence Interval Please"refer to the dacumenfadon for more tnfom don. NOTE: Formatting prevenls estimates near zero to appear as zero. * Lower bound of the 90% confidence interval Precipitation Intensity Estimates ft/hr)" Fl� ar5) min min Nl�'min 76�n [:]Fhr] hr hr •hr daY daY day day daYZ45day = 5.86 4.68 3.90 2.67 1.67 0.97 0.69 0.43 0.25 0.15 0:09 0.05 OA3 0.03' 0.02 0.01 0.01 0,01 6.95 5.55 4.65 3.21 2.02 1.Z8 0.84 0.52 0.30 0.18 07107 070 67 0.04. 0:03 D.02 0.02 0.01 0.01 8.14 6.51 5.49 3.90. 2.50 L51 i.08 0.67 0.39 0.23 0.13 Kf 0.05 0:44 0.03 0.02 0.02 0.01 lO 9.02 722 6.09 41 2.87 1.78 1.28 0.80 0.47 0.27 0.16 0.09 0.06 0.04 0.03 O.D2 0.02 4A2 25 ' I0.16 8.09 6.84 EE 337 EE LE 0.99. O.S8 0.34 0.20 0.11 0.07 0.05. 0.03 10.03 4.02 0.02 50 10.98 E.75 7.38 5FS67 3.77 2.50 1.83 1.15 0.68 0.40 0.23 0,12 OA8 O.D6 0.04 0.03 0.02 0.02 100 11.$2 .40 7.92 6.06 4.17 2.85 .12 134 0.7 O0.461 026 0.14 0.09 0.07 0.04 0.03 0.03 0.02 200 12.61 10.Ofl 8.41 6,55 4.59 3.24 2.43 1.53 0.92 0.53 0.30 0.16 0.10 4.08 0.05 0.04 0.03 0.02 0 Table 8.03a Value of Runoff Coefficient (C) for Rational Formula I I s 8-03.2 Land Use C Land Use C Business: Lawns: . Downtown areas 0.70-0.95 Sandy soil, flat, 20/ 0.05-0.10 Neighborhood areas 0-50-0.70 Sandy soil, ave., 2-7% 0.1 0.0.15 Sandy soil, steep, 7% 0.15-0.20 Residential: Heavy soil, flat, 2% 0.13-0.17 Single-family areas 0.30-0.50 Heavy soil, ave., 2-7% 0.18-0.22 Multi units, detached 0.40-0-60 Heavy soil, steep, 70/6 025-0.35 Multi units, attached 0.60-0.75 Suburban 0.25L0.40 Agricultural land: Bare packed soil Industrial: Smooth 0.30-0.60 Light areas 0.50-0.80 Rough 020-050 Heavy areas 0.60-0.90 Cultivated rows Heavy soil no crop 0.30-0.60 Parks, cemeteries 0.10-0.25 Heavy soil with crop 0.20-0.50 Sandy soil no crop 0.20-0.40 P€aygrounds 020-0.35 Sandy soil with crop 0.10-0.25 Pasture Railroad yard areas 0.20-0.40 Heavy soil 0.15-0.45 Sandy soil 0.05-0.25 Unimproved areas 0.10-0.30 Woodlands 0-05-0.25 Streets: Asphalt 0.70-0.95 Concrete 0.80-0.95 Brick 0.70-0.85 Drives and walks 0.75-0.85 Roofs 0.75-0.85 NOTE: The designer must use judgment to select the appropriate C value within the range for the appropriate land use_ Generally, larger areas with permeable soils, flat slopes, and dense vegetation should have lowest C values. Smaller areas with slowly permeable soils, steep slopes, and sparse vegetation should be assigned highest C values. Source: American Society of Civil Engineers The overland flow portion of flow time may be determined from Figure 8.03aa The flow time (in minutes) in the channel can be estimated by calculating the average velocity in feet per minute and dividing the Iength (in feet) by the average velocity. Step 4. Determine the rainfall intensity, frequency, and duration (Figures 8.03b through 8.03g—source: North Carolina State Highway Commission-, Ian_ 1973). Select the chart for the locality closest to your location. Enter the "duration" axis of the chart with the calculated time of concentration, Tr_ Move vertically until you intersect the curve of the appropriate design storm, then move horizontally to read the rainfall intensity factor, i, in inches per hour. Step S. Determine peak discharge, Q (ft /sec), by multiplying the previously determined factors using the rational formula (Sample Problem 8.03a). j JUN 0 3 2010 I BY: COASTAL SITE DESIGN, PC PO Box 4041 Wilmington, NC 28406 Phone: 910 791-4441 Fax: 910 791-1501 June 3, 2010 Chris Baker Express Review Permitting N.C. Department of Environment And Natural Resources Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Re:. Express Submittal FY09 French Creek BEQ P-1017 P-1047 Onslow County CSD Project No. 09-0211 Dear Chris: Enclosed please find the following items. - one (1 copy of the Stormwater Management Calculations - two (2) copies of sheets C-104, C-509. C-512 "Sedimentation & Erosion Control and Storm Water Management Plan" - two (2) copies project limits and drainage area map - two (2) copies of the grading plan and culvert profiles - Original stormwater application - Original O & M for wet basin - Check for $4,000 check # 2751 - Wet basin supplement Please call if you have any questions. Very truly yours, Rodney right Encl.: As noted above TD JUN 0 4 200 13Y: bXl�re_ 5 S cc: Calibre Engineering For DENR Use ONLY ` /ubmil: V;�_ North Carolina Department of Environment and(v ) Natural Resources Request for Express Permit Review l NC®ENR ConFlrm: �.? 7 FILL-IN all the information below and CHECK the Permit(s) you are requesting for express review. FAX or Email the completed form to Express Coordinator along with a completed DETAILED narrative site plan PDF file and vicinity mag same items expected in the application Pack e of the project location. Please include this form in the application package. • Asheville Region -Alison Davidson 828-296-4698;alison.davidson(a)ncmail.net • Fayetteville or Raleigh Region -David Lee 919-791-4203; david.lee(a?.rncmail.net • Mooresville & -Patrick Grogan 704-663-3772 or patrick.rtrostan(a.ncmail.net • Washington Region -Lyn Hardison 252-946-9215 or lyn.hardlson()a.ncmail.net • Wilmington Region -Janet Russell 910-350-2004 or janof. russell(o)ncmail.net NOTE: Project application received after 12 noon will be stamped in the following work day. Enter Related SW Permits of request SW SW SW SW SW & 5v% n Project Name: FY09 FRENCH CREEK BEQ P-1017, P-1047 County: ONSLOW Applicant: CARL BAKER Company: MARINE CORPS BASS CAMP LEJEUNE Address: BLDG 1005 MICHAEL ROAD City: MCB CAMP LEJEUNE, State: NC Zip: 28547-_ Phone: 910-451-2213, Fax: 910-451-2927, Email: cad.h.baker@usmc.mil Physical Location:1.3 MILES SOUTH OF HOLCOMB AND SNEADS FERRY INTERSECTON ON SNEADS FERRY ROAD Project Drains into SC:NSW waters — Water classification 1919 23 (for classification see-http://h2o.enr.state.nc.ustbimstrei)orts/reportsWB,htm1) Project Located in WHITE OAK River Basin. Is project draining to class ORW waters? N , within % mile and draining to class SA waters N or within 1 mile and draining to class HQW waters? N Engineer/Consultant: HOWARD RESNIK Company: COASTAL SITE DESIGN, PC Address: R0 80X 4041 City: WILMINGTON, State: NC Zip: 28406 Phone: 910-791-4441, Fax: 910-791-1501, Email: HOWARD@COASTALSITEDESIGN.COM MAY 2 6 2010 SECTION ONE: REQUESTING A SCOPING MEETING ONLY ❑ Scoping Meeting ONLY ❑ DWQ, ❑ DCM, ❑ DLR, ❑ OTHER: SECTION TWO: CHECK ONLY THE PROGRAM (S) YOU ARE REQUESTING FOR EXPRESS PERMITTING ❑ 401 Unit ❑ Stream Origin Determination: _ # of stream calls — Please allach TOPO map marking the areas in questions ❑ Intermittent/Perennial Determination: _ # of stream calls — Please attach TOPO map marking the areas in questions ❑ 401 Water Quality Certification ❑ Isolated Wetland (_linear ft or acres) ❑ Riparian Buffer Authorization ❑ Minor Variance ❑ Major General Variance ® State Stormwater ® General, ❑ SFR, ❑ SFR < 1 ac. ❑Bkhd & Bt Rmp, ❑ Clear & Grub, ❑ Utility ❑ Other ❑ Low Density ❑ Low Density -Curb & Gutter — # Curb Outlet Swales ❑ Off -site [SW (Provide permit #)] ® High Density -Detention Pond 1 # Treatment Systems ❑ High Density -Infiltration _ #Treatment Systems ElHigh Density -Bio-Retention _ # Treatment Systems ❑ High Density —SW Wetlands _ # Treatment Systems ❑ High Density -Other _ # Treatment Systems / ❑ MOD:❑ Major ❑ Minor ❑ Plan Revision ❑ Redev, Exclusion SW (Provide permit#) ❑ Coastal Management ❑ Excavation & Fill ❑ Bridges & Culverts ❑ Structures Information ❑ Upland Development ❑ Marina Development ❑ Urban Waterfront ❑ Land Quality ❑ Erosion and Sedimentation Control Plan with - acres to be disturbed.(CK # (for DENR use)) SECTION THREE — PLEASE CHECK ALL THAT IS APPLICABLE TO YOUR PROJECT (for both scopinq and express meeting request Wetlands on Site ❑ Yes ® No Buffer Impacts: ❑ No ❑ YES: _acre(s) Wetlands Delineation has been completed: El Yes El No Isolated wetland on Property ❑ Yes ❑ No US ACOE Approval of Delineation completed: ❑ Yes ❑ Na 404 Application in Process wl US ACOE: ❑Yes ❑ No Permit Received from US ACOE ❑ Yes ❑ No +**************++++++*+++*+*+**********++++++*+++*+****+Par DENR use only*+**+*+*+++**+++++++++*+**+*+*******+*+*+++****+*++**+*+***+ Fee Split for multiple permits: (Check 9 ) Total Fee Amount $ SUBMITTAL DATES Fee I SUBMITTAL DATES Fee CAMA $ Variance (❑ Maj; ❑ Min) 1 $ SW (❑ HD, ❑ LID, ❑ Gen) $ 401: $ LQS $ Stream Deter,_ $ NCDENR EXPRESS March 2009 COASTAL SITE DESIGN, PC PO Box 4041 Wilmington, NC 28406 Phone: 910 791-4441 Fax: 910 791-1501 FOR STORMWATER EXPRESS REVIEW May 2010 PROJECT NAME: French Creek P-1017 P-1047 MCB Camp Lejeune, NC Onslow County PROJECT'DESCRIPTION: The project area for this development is 14.56 acres with 13 acres of disturbance. There are no wetlands within the project limits. This project is for the construction of three BEQ buildings, parking lot and recreation courts. The owner is the United States Marine Corps. Water and sewer utilities will be provided by the BASE. Stormwater from the site will drain to SC, NSW waters located in the White Oak River Basin (index # 19-23). This project is subject to Coastal Stormwater Regulations. The project will be high density utilizing underground conveyance pipe and open channels to discharge stormwater into a wet basin designed for 90% TSS removal. All proposed impervious inside the project limits will be collected. Proposed impervious for the site is 46%. There are no buffer requirements for the development. No offsite runoff will be entering the site. The site will have access to Sneads Ferry Road from an existing road that runs into the site. EC_ S performed SH WT determinations for the site and their findings were utilized to design the pond. PROJECT BMP: high density/ wet basin. STORM WATER ENGINE-ER/CONSULTANT: Coastal Site Design, PC PO Box 4041 Wilmington, NC 28406 Rodney Wright rodncy@coastalsitedesign.com 910 791 4441 office 910 791 1501 fax F,7M:AY 2 5 2010 B , ,P(AC-E 'TRa "I, ii A, 'i OF '$NS to I 1 11 1 , '..WrS OF MSTLPBMq LIMITS Dr DISIURBANLE LNE WILL GE NEW FREE LIRE PLACE IAfE PROTCnopi ALONG IAMITS OF DlsT11RDMCE lvl,"-AT Id J (Ulu I inch � l00 IL. Hodson Le] Russell, Janet To: howard@coastalsitedesign.com Cc: RODNEY WRIGHT; Towler CIV David W Subject: RE: French Creek BEQ Project Thanks so much. Then consider the meeting scheduled for 11:30 on June V with Chris Baker. From: Howard Resnik [mailto:howard@coastalsitedesign,com] Sent: Thursday, May 27, 2010 10:06 AM To: Russell, Janet Cc: 'RODNEY WRIGHT Subject: RE: French Creek BEQ Project That will work out great... Howard Resnik, PE, LEED® AP Coastal Site Design, PC 3805 Cherry Avenue Wilmington, NC 28403 910 791 4441 office 910 791 1501 fax www.coastalsitedesign.com It is the professional opinion of Coastal Site Design, PC that this electronic information provides design information current as of the date of its release. It is the responsibility of the receiver of this document to examine it and determine whether it is the information requested. In the deliverance of this file we make no promise as to the usability or compatibility of this file. This file shall not be considered a certified document. From: Russell, ]anet[mailto:janet.russell@ncdenr.gov] Sent: Thursday, May 27, 2010 10:01 AM To: howard@coastalsitedesign,com Cc: RODNEY WRIGHT Subject: French Creek BEQ Project Howard / Rodney: For the French Creek Submittal meeting — we are currently scheduled to meet at 9:30 AM on June 3. 1 am trying to coordinate David Towler being in the office for another meeting at 2:00 that same day. Is there any way we could move up your meeting to 11.30 so that David could meet with you guys, go to lunch and then come back at 2:00 for the other meeting? Please let me know if 11.:30 works for your schedule. I think he would appreciate it. Thank YouW Janet /_ �/O a f For DENR Use ONLY v� Reviewer: (::, a li?_H AN � North Carolina Department of Environment and Z-3� Natural Resources Submit: NC®ENR Request for Express Permit Review rime l 1 _�- to i� 1� confirm: [s� FILL-IN all the information below and CHECK the Permit(s) you are requesting for express review. FAX or Email the completed form to Express Coordinator along with a completed ,DETAILED narrative, site plan (PDF tile) and vicinity map (same items expected in the application package of the project location. Please include this form in the application package. a • Asheville Region -Alison Davidson 828-296-4698;alison.davidson(d,)ncmail.net • Fayetteville or Raleigh Region -David Lee 919-791-4203; david.lee(a)ncmail.net • Mooresville & -Patrick Grogan 704-663-3772 orpatrick.uroclan(ancmail.net • Washington Region -Lyn Hardison 252-946-9215 or lyn.hardison(a.ncmail.net • Wilmington Region -Janet Russell 910-350-2004 or ianet.russell(a-ncmaii.net NOTE. Project application received after 12 noon will be stamped in the following work day. Enter Related SW Permits of request SW SW SW SW SW fA Project Name: FRENCH CREEK BEQ P-1017, P-1047 County: ONSLOW Applicant: CARL BAKER Company: MARINE CORPS BASE CAMP LEJEUNE Address: BLDG 1005 MICHAEL ROAD City: MCB CAMP LEJEUNE, State: NC Zip: 28547 Phone: 910-451-2213. Fax: 910-451-2927, Email: carl.h,baker@usmc.mil Physical Localion:1.3 MILES SOUTH OF HOLCOMB AND SNEADS FERRY INTERSECTON ON SNEADS FERRY ROAD Project Drains into SC:NSW waters - Water classification 1919 23 (for classification see- httD:llh2o.enr. state. nc.uslbimslreportslreportsWB.htm1) Project Located in WHITE OAK River Basin, Is project draining to class ORW waters? N , within'/z mile and draining to class SA waters N, or within I mile and draining to class HQW waters? N Engineer/Consultant: HOWARD RESNIK Company: COASTAL SITE DESIGN, PC Address: P BOX 4041 City: WILMINGTON, State: NC Zip: 28406-_ Phone: 910-791-4441, Fax: 910-791-1501, Email: HOWARD@COASTALSITEDESIGN.COM FEB 0 1 2010 SECTION ONE: REQUESTING A SCOPING MEETING ONLY ® Scoping Meeting ONLY ® DWO, ❑ DCM, ® DLR, ❑ OTHER: SECTION TWO: CHECK ONLY THE PROGRAM (S) YOU ARE REQUESTING FOR EXPRESS PERMITTING ❑ 401 Unit ❑ Stream Origin Determination: _ # of stream calls - Please attach TOPO map marking the areas in questions ❑ In term ittent/Peren n ial Determination:— # of stream calls - Please attach TOPO map marking the areas in questions ❑ 401 Water Quality Certification ❑ Isolated Wetland (linear fl or acres) Cl Riparian Buffer Authorization ❑ Minor Variance ❑ Major General Variance ❑ State Stormwater ® General ❑ SFR, ❑ SFR < 1 ac. ❑Bkhd & Bt Rmp, ❑ Clear & Grub, ❑ Utility ❑ Other ❑ Low Density ❑ Low Density -Curb & Gutter _ # Curb Outlet Swales ❑ Off -site [SW (Provide permit #)] ElHigh Density -Detention Pond _ # Treatment Systems ❑ High Density -Infiltration _ #Treatment Systems ❑ High Density -Bio-Retention _ # Treatment Systems ❑ High Density --SW Wetlands _ # Treatment Systems ❑ High Density -Other _ # Treatment Systems / ❑ MOD:❑ Major ❑ Minor ❑ Plan Revision ❑ Redev. Exclusion SW (Provide Permit #) ❑ Coastal Management ❑ Excavation & Fill ❑ Bridges & Culverts ❑ Structures Information ❑ Upland Development ❑ Marina Development ❑ Urban Waterfront ® Land Quality ® Erosion and Sedimentation Control Plan with 13 acres to be disturbed.(CK # (for DENR use)) SECTION THREE - PLEASE CHECK ALL THAT IS APPLICABLE TO YOUR PROJECT (for both scooina and express meetina reauest Wetlands on Site ❑ Yes ® No Buffer Impacts: ❑ No ❑ YES: _acre(s) Wetlands Delineation has been completed: ❑ Yes ❑ No Isolated wetland on Property ❑ Yes ❑ No US ACOE Approval of Delineation completed: ❑ Yes ❑ No 404 Application in Process wl US ACOE: ❑ Yes ❑ No Permit Received from US ACOE ❑ Yes ❑ No «*++++++**«++++++*+*+*«*«*****«r«**++++++***«********+++tor DENR use Fee Split for multiple permits: (Check # i Total Fee Amount S SUBMITTAL DATES Fee SUBMITTAL DATES Fee CAMA $ Variance (❑ Maj; ❑ Min) $ SW (❑ HD, ❑ LID, ❑ Gen) $ 401: $ LQS $ Stream Deter— $ 02o(.612 ?3ecQ ci-c-e� NCDENR EXPRESS March 2009 LIMITS OF OISTURB, 14.00 1 COASTAL SITE DESIGN, PC PO Box 4041 Wilmington, NC 28406 Phone: 910 791-4441 Fax: 910 791-1501 FOR STORMWATER EXPRESS REVIEW February I, 2010 PROJECT NAME: French Creek P-1017 P-1047 MC13 Camp Lejeune, NC Onslow County PROJECT DESCRIPTION: The project area for this development is 14.56 acres with 13 acres of disturbance. There are no wetlands within the project limits. This project is for the construction of three BEQ buildings, parking lot and recreation courts. The owner is the United States Marine Corps. Water and sewer utilities will be provided by the BASE. Stormwater from the site will drain to SC, NSW waters located in the White Oak River Basin (Index # 19-23). This project is subject to Coastal Stormwater Regulations. The project will be high density utilizing underground conveyance pipe and open channels to discharge stormwater into a wet basin designed for 90% TSS removal. All proposed impervious inside the project limits will be collected. Proposed impervious for the site is 46%. There are no buffer requirements for the development. No offsite runoff will be entering the site. The site will have access to Gonzalez, Street once the Gonzalez Street extension is constructed. ECS performed SHWT determinations for the site and their findings were utilized to design the pond. PROJECT BMP: high density/ wet basin. STORMWA` E.R ENGINEI.R/CONSUL`I'ANT: Coastal Site Design, PC PO Box 4041 Wilmington, NC 28406 Rodney Wright rodney@coastalsitedesign.com 910 791 4441 office 910 791 1501 fax FFEB 0 1 2010 BY: