HomeMy WebLinkAboutSW3210101_800- Signed EZ Form_20210324SUPPLEMENT-EZ COVER PAGE I FORMS LOADED PROJECT INFORMATION 1 Project Name The Glenns 2 Project Area (ac) 46.95 Acres 3 Coastal Welland Area (ac) N/A _4 . 5 Surface Water Area (ac) N/A Is this project High or Low Density? Ifth 6 Does this project use an off -site SCM? No [COMPLIANCE WITH 02H.1003(4) 7 Width of vegetated setba�rovid�eecl (feetl_ 8 Will the vegetated setback remain vegetated? 9 , Is BLIA other that as listed in .1 003(4)(c-d) out of the setback? 10 1 Is streambank stabilization proposed on this project? N/A Yes No NUMBER AND TYPE OF SCMs: 1 Infiltratiw System 0 12 Bioretention Cell 0 13 Wet Pond 2 Stormwater Wetland 0 ._�114 15 Permeable Pavement 0 16 1 Sand Filter 0 0 0 0 17 18 Rainwater Harvestino (RWH) Green Roof 19 Level Spreader -Filter Strip (LS-FS) 20 Disconnected Impervious Surface QIS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 26 §_q)(filter Filterra 0 L 0 I FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Michael D. Duval, PE Project Manaa r 2a OEgaruzatm; The John R. McAdams Company,, In 29 Street address: 3430 Toringdon Way, Suite 110 30 C�y., State, Zip: Charlotte, NC M77 31 Phone riumber(s): 704.527.0800 32 Email: mduval@mcadamsco.com certifit'glion sleternent� I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here, "\ � , % I % I I I i I I , I \A CA % SE L 048769 ro�_��e Signature of Designer 3/1-7/9L \ Date DRAINAGE AREAS 1 5 1 Is this a hiah density�project? Yes 2 f So , number of drainage areas/SCMs f.,.i 2 r 3 F 1 , part of this project subject to previous rule rVI.-I ons? No I- FORMS LOADED DRAINAGE AREA INFORMATION Entire Site 1 2 -4 Type of SCM Total BUA in project s ft) Wet Pond Wet Pond 613936 sf 318873 sf 295063 sf —5 New BUA on subdivided lots (subject to permitting) 6 (sq_ft)_ 230411 sf� 24961 -sf 205450 sf - New BUA outside of subdivided lots (subject to -7 p 169258 sf 79645 sf 89613 sf 8 Offsite - total area (sq.ft) 223343 sf 223343sf 9 Offsite BUA (sq 1). 66533sf 66533 sf 10 Breakdown of new BUA outside subdivided lots: Parking (sq ft) - - - Sidewalk (sg ft) 51560 sf 29349 sf 22211 sf Roof (sq ft) - - Roadway (sq ft) 117698 sf 50296 sf 67402sf Future (sq ft) - Other, please specify in the comment box below Jsq ft) 11 New infiltrating permeable pavement on subdivided lots (sq ft) 12 New infiltrating permeable pavement outside of l subdivided lots (sq ft) 13 Exisitng BUA that will remain (not subject to permitting) (sq ft) 66533sf 66533 sf 14 Eyisbna BUA that is already permitted (sq ft). 66533sf 66533 sf 15 Existing BUA that will be removed (sq ft) 16 Percent BUA 30% 33% 23% 17 pEsiarLstorm (inches) - 1 in 1 in 18 Design volume of SC M (cu ft) 33397 cf 23472 cf I 19 Calculation method for design volume SA/DA SAIDA — — ADDITIONAL INFORMATION TPlease use this space to provide any additional information about the 20 ldrainage area(s): WETPOND I 10ro1nage area number I 1 1 2 21 Design volume cyf SCM (cu ft) GENERAL -MIX FROM 02H . 10 3, Is the SCM sized to treat the SW from all surfaces at build -out? L 33397 cf 23472 cf Yes V.�s 4 Is the SCM located away from contaminated soils? Yes Yes 5 What are the side slopes of the SCM (H:Y)? 3:1 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No No 7 Are the inlets, outlets, and receiving stream protected from erosion (1 0-year storm)? Yes Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes Yes 9 What is the method for dewatering the SCM for maintenance? Pump (preferred) Pump (preferred) 10 If eipPI(Cilble. Will ft SCM be cleaned out after congrijapril? Yes Yes 11 Does the maintenance access comply with General MDC_(8)? Does the drainage easement comply with General M15C (9)? If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? Is there an O&M Agreement that complies with General MDC (11)? To —thwe. an G&M Plan that complies with Genwil MDC (12)7 Does the SCM follow the device specific MDC? Yes Yes 12 Yes Yes 131 No No 14 Yes Yes 15 Yes Yes 16 Yes Yes 17 Was the SCM designed by an NC licensed professional? WET POND MDC FROM 02H .105 18 Method used 19 Has a stagefstorage table been provil In the calculaons? yba SAJDA yed SA/DA Yes Yes 20 Elevation of the excavated main pool depth (bottom of sediment removal) (fmsl) 567.00 569.00 21 Elevation of the main pool bottom -(top of sediment removal) (fmsi) 571.50 572.40 22. Elevation of the bottom of the vegetated shelf (finsl) 572.00 573.50 23 Elevation of the permanent pool (fmsi) 572.50 574.00 24 Elevation of the top of the vegetated shelf (fmst) '�ie_vation oF%—a iemp--ry PEKA (frrw) Surface area of the main -permanent pool �square feet) 573.00 674.60 25 573.30 574.50 26 37552:1 42468:1 27 _kj Volume of the main permanent pool (cubic feet) Average depl� ofiiie m-ewin—pool #sei� 123084 cf 124235 cf 3.84 ft 3.68 It 29 Average depth equation used Equation 2 Equation 2 30 If using equation 3, main pool perimeter (feet) 31 �_using equatlan 3. width of submerged veg. shelf (feet) 32 Volume of the forebay (cubic feet) 21062 cf 32022 cf 33 T�This 15-270% ;Ft -he volume in the main pool? 34 Clean -out depth for foreWy (Inches) Yes Yes 12 in 19 in 35 DeWp VoiUme of SCM (cU ft) 33397 cf 23472 cf 36 Is the outlet an orifice or a weir? Orifice Orifice 37 If orifice, orifice diameter (inches) 3 in 3 in 38 FrW_!j� Weir height pmhas) 39 ei r, weir length (Inches) - 40. Drawdown time for the temporary pool (days) 3.57 4.13 Are ffie inlet(s) and outlet located in a manner that avoids short- 41 circuiting? Yes Yes —421Are bemns or baffles proVided to Improve the flow path? Yes Yes 43 Depth of for" at entrance @tchesj 66 in 60 in 44 Depth of forebay at exit (inches) Does wate_rflow out oft—ho forebay In a non-eFasimeman-ner? 66 in 60 in 45 Yes Yes 46 Wi of the vagetated shelf (feet) 6 ft 6 ft 47 Slope of vegetated shelf (H:V) 6:1 6:1 48,permanent Does the orifice drawdown from below the top surface of the pool? No Yes 49 oes the pond minimize impacts to the receiving channel from the 1- yr, 24-hr storm? Are fountains proposed? (if Y, please provide documentation that MDC(9) is met.) Yes Yes 50 No No 51 Is a trash rack or other device provided to protect the outlet system? Yes Yes 52 Are t e dam and embankment planted in non -clumping turf grass? Yes Yes 53 . es of turf that wffl be Used on Um dam and embankment Tall Fescue Tall Fescue 54 Has a pTanting plan been . provided _for_ffie­ve6�_tated_sh__elf? Yes Yes ADDITIONAL INFORMATION PTetapsoenuse this space to provide any additional information about the 55 we d(s): Wet Pond 3 5:01 PIM 3/17/2021