Loading...
HomeMy WebLinkAboutNCG080909_Inspection_20210323ROY COOPER Governor DIONNE DELLI-GATTI Secretary BRIAN WRENN Director Greenwood Motor Lines, Inc. Attention: Tony Scott 600 Gillam Road Wilmington, Ohio 45177 NORTH CAROLINA Environmental Quality March 23, 2021 Subject: Compliance Evaluation Inspection Greenwood Motor Lines, Inc. NPDES Certificate of Coverage — NCG080909 Rowan County, North Carolina Dear Ms. Scott, Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection we conducted at the RL Carriers China Grove facility on March 18, 2021. Please note that in the stormwater inspection report summary we ask that you address the minor deficiencies with fueling station and disturbed areas noted in the inspection report. The report should be self-explanatory; however, should you have any questions, please do not hesitate to contact me at (704) 663-1699 or by E-mail at james.moore@ncdenr.gov. Enclosure cc: Laserfiche Sincerely, es Moore Assistant Regional Engineer N . C--D_E Q�� DMIM M of EnIkonmental WnINy North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources Mooresville Regional Office 1 610 East. Center Avenue, Suite 301 1 Mooresville, North Carolina 28115 704.663.1699 Permit: NCG080909 SOC: County: Rowan Region: Mooresville Contact Person: Toni Scott Compliance Inspection Report Effective: 11/01/18 Expiration: 05/31/21 Owner: Greenwood Motor Lines Inc Effective: Expiration: Facility: R+L Carriers - CHR 175 N Pine Rdg Rd Title: China Grove NC 28023 Phone:800-543-5589 Directions to Facility: from 185 southbound at the us 29 connector exit go south 2.5 mi on us 29 to pine ridge rd turn left onto pine ridge go .5 mi to the entrance on the rt System Classifications: SWNC, Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 03/18/2021 Entry Time 04:OOPM Exit Time: 05:10PM Primary Inspector: Lily C Kay Phone: 704-663-1699 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Transportation wNehicle Maintenance/Petroleum Bulk/Oil Water Separator Stormwater Discharge COC Facility Status: 0 Compliant ❑ Not Compliant Question Areas: Storm Water (See attachment summary) Page 1 of 3 Permit: NCG080909 Owner - Facility: Greenwood Motor Lines Inc Inspection Date: 03/18/2021 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: The Stormwater Pollution Prevention Plan (SWPPP) and related documentation was complete including employee training records, monitoring records, and the annual certification. The facility appeared well operated and maintained except for minor deficiencies with the fueling station and disturbed areas. If you have questions, contact me at Lily. Kay@ncdenr.gov or by phone at (704) 235-2137. Page 2 of 3 Permit: NCG080909 Owner - Facility: Greenwood Motor Lines Inc Inspection Date: 03/18/2021 Inspection Type : Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Does the site have a Stormwater Pollution Prevention Plan? # Does the Plan include a General Location (USGS) map? # Does the Plan include a "Narrative Description of Practices"? # Does the Plan include a detailed site map including outfall locations and drainage areas? # Does the Plan include a list of significant spills occurring during the past 3 years? # Has the facility evaluated feasible alternatives to current practices? # Does the facility provide all necessary secondary containment? # Does the Plan include a BMP summary? # Does the Plan include a Spill Prevention and Response Plan (SPRP)? # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? # Does the facility provide and document Employee Training? # Does the Plan include a list of Responsible Party(s)? # Is the Plan reviewed and updated annually? # Does the Plan include a Stormwater Facility Inspection Program? Has the Stormwater Pollution Prevention Plan been implemented? Yes No NA NE ■❑❑❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ ❑ ❑ ❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ ❑ ❑ ❑ ■❑❑❑ ■❑❑❑ Comment: The Stormwater Pollution Prevention Plan (SWPPP) and related documentation was complete including employee training records, monitoring records, and the annual certification. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? 0 ❑ ❑ ❑ Comment: Qualitative monitoring records were available and complete. Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? E ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? 0 ❑ ❑ ❑ Comment: Analytical monitoring records were available and all parameters were within the benchmark limitations. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ # Were all outfalls observed during the inspection? 0 ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? 0 ❑ ❑ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ ❑ N ❑ Comment: Minor deficiencies were observed and documented at the time of inspection with sheen from the fueling station, turbid water from disturbed areas, and a small pile of concrete waste dumped on a grassed area. These deficiencies must be addressed in a timely manner. Page 3 of 3