HomeMy WebLinkAboutSW3200903_Signed SuppEZ_20210310SUPPLEMENT-EZ COVER PAGE
F2aMS LOADED
COMPLIANCE WITH 02H .1003(4)
7 Width of vegetated setbac4j�m ided feet rrfa
8 Will the vegetated setback remain tated? _
9 If BUA Is proposed In the setback, does it meet NCAC_0_2H.1003f4Xr d}? _ _ _
10 Is streambank stabilization vromsed on this Droiect?
NUMBER AND TYPE OF SCMs:
21
22
23
24
25
26
FORMS LOAD-0
:SIGNER CERTIFICATION
27Name and Tale:
28 O nni_zation:
29 street address:
32 IEmail:
Carlton Burton, PE _
_Burton Enpineedn Associata_s
5950 Fairvlew.Road, Suite 100
Charlotte, NC 28210
7045538881
cburtonburtoneng,00m
Certification Statement:
I certify, under penalty of law that this Supplement-FZ form and all supporting information were prepared under my direction or supervision; that the
information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete, and that the engineering plans,
specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here.
Desfener
SEAL _
12557
fi
y (i•
4,,
u11111a11111 O
sea/
f)g-�
Signature of Designer
Date
3 / ►43Iz1
DRAINAGE AREAS
1 Is this a high densq project? Yes
2 If so number -of drainage areas/SCMs _ 1
3 Does this ro e_ct have low density areas? No
4 If so number of low density drainage areas 0
Is all/part of this project subject to previous rule
5 versions? No
FORMS MAQEb
AREA INFORMATION
s drainage area (sq ft)
BUA in project (sq ft)
BUA on subdivided lots (subject to
ittin sgft� _
BUA not on subdivided lots (subject to
45.261
---- _ 1775941 sf
sf ...--
- Sidewalk (sq ft
-.Roof ft)
- Roadway s ft
- Future ft _ _
- Other, please specify in the comment box
below j`sq ft) - -
New Infiltrating permeable pavement on
subdivided lots Jsq ft}
New inflltrating permeable pavement not on
subdivided lots Qq ft)
Feasting BUA that will remain (not subject to
permitting) (sq ft)
5_345 sf
sf
_735550
618365 sf
346365 sf
13
14
_ 15
-
_ sf
sf
sf
16 Existina BUA that is already permitted (sq ft) __ _ sf
17 Existing BUA that will be removed Jsq ftJ _ sf
18 Percent BUA _ _ _ 909E
19 Design storm (inches) _ 1.0 in
20 Design volume of SCM feu ftl 141293
21 lCalculation method for design volume Simple Me
ADDITIONAL INFORMATION
Please use this space to provide any additional
22 drainage area s
WET POND
1 Drainage area number _ 1
21 Minimum mvired treatment volume (cu ft) 141309 of
3 is the SCM sized to treat the SW from all surfaces at build -out?
Yes
_
4 Is the SCM located away from contaminated soils?
Yes
5 What are the side. sioles of the SCM (H:V)?
3:1
_
6 Does the SCM have retaining walls, gabion walls or other
pnj2LnGerqP side slopes?
No
Are the inlets, outlets, and receiving stream protected from erosion
7 10-roar stop 77
Yes _
e Is there an overflow or bypass for Inflow volume in excess of the
ldesipn volume?
Yes
9 What is the method for dewatering the SCM for maintenance?
Drawdown Orifice
- - --
10 If applicable, _will the_SCM be cleaned out after construction?
Yes
11 r Does the maintenance access comply with deneral MDC B ?
Yes
12 D the theoes th drainage easement oomply with General MDC 8 ?
13 If the SCM is on a single family lot, does (will7) the plat comply with
General MDC 10 7
Yes
N/A
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
15
Yes
Is there an 0&M Plan that complies with General MDC (1k?
_
Does the SCM follow the device specific MDC?
16
Yes
17
Was the SCM deskmed by an NC licensed arofessional?
Yes
1 %Sizing
method used
SAIDA
19
Has a slegelstorage table been provided in the calculations?
Elevationof the excavated main pool depth (bottom of sediment
removal) (fmsl)
Yes
20
8�'�
21
Elevation of the main pool bottom (top of sediment removal) (fmsl)
827.00
830.00
22 Elevaton of the bottom of the vegetated shelf fmsl
23 Elevation of the permanent pool (fmso
Eleve6ofthetoy of the vegetated shelf (fmso
830.50
831.00
Elevation of the temporary pool (finsl)
830.76
Surface area of the main permanent ppol (square feet)
525
105694
Volumeof the main permanent pool (cubic teeth
416434cfAve
depth of the main pool feet
29 Average dg4h equation used
30 K using equation 3, main pact perimeter fee
31 If using equation 3, width of submerged vpg.-shelf (feet)
32 Volume of the foreba bic feet] —
80368 cf
_ -
33 Is this 15-20% of the volume in the main PWI?
Yes
—
34 Clean -out de _for foreinches
12 In
35 Design volume of SCM (cu ft)
282704 of
__—
36 Is the outlet an orifice or a weir?
Orifice
_ _
37 If orifice, orifice diameter finches)
2 6"
_
38 If weir, weir height Cinches)
_
_
39 If weir, weir length (inches) _
40 Drewdown Ume for the temporary p" (da�sj
_ —
3
41 Are the inlet(s) and outlet located in a manner that avoids short -
_ ;circuiting? _
-
Yes
Yes
__
42'Are berms or baffles provided to improve the flow path?
_-
43_Depth of foreba�r at entrance (inches
BB in
_
44,Depth of fore4y at exit (inches}
54 in
45 Does water flow out of the forebay in a non -erosive manner?
Yes
46,Width of the v2qalaked shelf {feet)
_
6 ft
..
48Doe47 Slope_ of vogetated shelf (H.-V) _
s the orifice drawdown from below the top surface of the
48
pernanentpod? _
—
6:1
Yes
Yes
49 Does the pond minimize impacts to the receiving channel from'lha 1
24-hr storm?
Are fountains proposed? (if Y, please provide documentation that
MDCL9) is meta
No
51 Is a trash rack or other device provided to protect the outlet system?
Yes
52 Are the dam and embankment planted in non -dumping turf grass?
Yes
58 Species of turf that will be used on the dam and embankment
54 Hasa lantin plan been vfded for the y2gqtatedl shah?
_
Yes
ADDITIONAL INFORMATION —
-
55!Please use this space to provide any additional information about
the wet pond(s):
Net Pond 1 2:32 PM 3/10/2621