HomeMy WebLinkAboutNC0001121_NPDES Permit Renewal_20060524MEMORANDUM
•TO:
FROM:
May 24, 2006
Carolyn Bryant
NPDES Unit, Point Source Branch
Michael Lawyer, Environmental Technician
Fayetteville Regional Office
THROUGH: Belinda Henson, Regional Supervisor
Surface Water Protection Section
Fayetteville Regional Office
SUBJECT: Minor NPDES Permit Renewal
Danaher Sensors & Controls WWTP
NPDES Permit NC0001121
Bladen County
Michael F. Easley, Governor
William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
Alan W: Klimek, P.E., Director
Division of Water Quality
6: a
Please find below our regional comments for the subject minor permit renewal.
Applicant is making two requests concerning the pounds per day limits for total suspended solids and
the 90% effluent concentration for the acute toxicity testing. Both requests can be found on page 4 of
the application under item 15.
The current permit as well as the renewal application reflects that there are 4 outfalls. It should be
noted, however, that this facility has only one point of discharge (currently identified as outfall 004) to a
receiving stream. This office requests that the renewed permit reflect only one discharge location and
that all parameters including flow be associated with it. Another option would be to decrease the
frequency of flow monitoring for the other outfalls to weekly instead of continuous. Also, permit
information in BIMS currently shows that this facility's permitted flow is 5,000,000 gpd, which
obviously needs to be corrected.
A review of compliance data from BIMS for the period beginning January 2004 through May 2006
revealed five limit violations for varying parameters. A copy of the violation report from BIMS and the
most recent compliance inspection report dated December 8, 2005 is attached.
No special conditions, limitations or monitoring are suggested at this time.
In keeping with current basin -wide strategy; the Fayetteville Regional Office recommends that this permit
be renewed with consideration given to the above requests.
Attachments (2)
cc: Central Files
NorthCarolina
Naturaffj
North Carolina Division of Water Quality 225 Green Street — Suite 714 Fayetteville, NC 28301-5043 Phone (910) 486-1541 Customer Service
Internet: www.ncwaterquality.org ' FAX (910) 486-0707 1-877-623-6748
An Equal Opportunity/Affirmative Action Employer — 50% Recycledll0% Post Consumer Paper
MONITORING REPORT(MR) VIOLATIONS for:
s Between['
:.Facility Name:
i � 5
o MaJr, Mmor•'.
alaticq/O ego
ibtiasi
Report Date: 05/24/06
rogra'm'Catego
iolatioh Aciidn
Page: 1 of 1
PERMIT: NC0001121 FACILITY: Dynapar Corporation - Danaher Industrial Controls WWTP COUNTY: Bladen
REGION: Fayetteville
Limit Violation
MONITORING OUTFALL VIOLATION UNIT OF CALCULATED
REPORT / PPI LOCATION PARAMETER DATE FREQUENCY MEASURE LIMIT VALUE VIOLATION TYPE VIOLATION ACTION
08 - 2005 004 Effluent Copper, Total (as Cu) 08/16/05 Weekly Ibs/day 0.66 0.9 Daily Maximum Exceeded Proceed to NOV
11 - 2004 004 Effluent Oil & Grease 11/30/04 Weekly Ibs/day 10.15 11.7 - Daily Maximum Exceeded Proceed to NOV
02 - 2006 004 Effluent Solids, Total Suspended 02/28/06 Weekly ' lbs/day 11.71 13.8 Daily Maximum Exceeded None
02 - 2006 004 Effluent Solids, Total Suspended 02/28/06 Weekly Ibs/day 6 6.4 Monthly Average Exceeded None
01 - 2006 004 Effluent Zinc, Total (as Zn) 01/24/06 Weekly Ibs/day. 0.51 0.97 Daily Maximum Exceeded Proceed to NOV
LVLL1.114c1 L'. 1:t1JJGJ, VV VGIILVL
vx���CA.
Wll'. _ _ - :retary
North Carolina Department of Environment ;and Natural Resources
Alan W. Klimek, P.E:; Director ,
Division of. Water -Quality
Rodney H Lang, EATS Engineer
Dynapar Corporation
2100 .W Broad'St
Elizabethtown, NC 28337
SUBJECT December 2, 2005 Compliance Evaluation Inspection
Dynapar Corporation
Danaher Industrial Controls WWTP
Permit No: NC0001121
Bladen County
Dear Mr: Lang:
Enclosed please find a copy of the Compliance Evaluation Inspection Repor(from the inspection
conducted on December 2, 2005.. Thefacility was found to be in Compliance with permit NC0001121.
Please refer to the enclosed inspection report for additional observations and cominents. If you or your
staff has an
ions, please call me at 910-486-1541..
Michael Lawyer -
Environmental Technician
North Carolina Division of Water Quality
Internet: h2o.enr.state.nc.us
An Equal Opportunity/Affirmalve Action. Employer - 50% Recycled/10% Post Consumer Paper
NorthCarolina
Naturally
225 Green Street -Suite 714 Fayetteville, NC'2830-1-5043 Phone (910) 486-1541 Customer Service
FAX (910) 486-0707 1-877-623-6748"
y quest
NPDE$;, -.. yrlmo/day.. Inspection Type
NCO 001121: i 05112/02 L_l7 LCJ
•
Section D: Summary of Finding/Comments Attach additional sheets of narrative and checklists as necessary)
Facility, is a Physical/Chemical plant designed to treat wastewater from chrome plating; process and for
cyanide. ---A polymer is added to the:,chrome batchtank'toaid in. the removal of.metaisand other;solids. The
pH is adjusted, in both the chrome -and cyanide batch tanks_ and the wastewater is then. pumped to a
rectangular clarifier for further solids removal and treatment. Overflow from the cl'arifieris.then'Combined
with non -contact cooling water and remeduated groundwater before reaching the: receiving waters. After
inspecting the"treatment units of the plant; a records review was conducted corriparin g lab ;reports from. `
PACE Analytical to: the Discharge Montoring Reports. No transcription errors were found: Facility appeared
to be very well operated and maintained,
1
Page # 2
I ,: Permit: NC0001.121
Inspection Date: 12/022005
Laboratory
Incubator'(BOD) set to 20:0 degrees Celsius +/-1.0 degrees?
Comment: Facility uses PACE Analytical for their testing
Owner Facility, Danaher Industrial Controls.WWTP
inspection Type: Compliance Evaluation-
•
Record Keeping
Are records kept and maintained as required by the permit? . .
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis,
Name of person performing analyses.
Transported COCs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ? '
(If the facility is = or > 5 MGD permitted flow) Do they operate 24%7 with a certified operator on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade Tess or greater than the facility classification?
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Comment:
Effluent Sampling
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
Is proper temperature set for sample storage (kept at 1'.0 to 4.4 degrees Celsius)?
Yes' NO NA NE
■ O00
N 000
■ nn❑
• ❑ ❑ ❑
■ ❑❑❑
■ '
■
■
■
■
■
■ ❑❑❑ -
❑ n■❑
❑ ❑ ■ ❑
■ 000,
f•Q❑n
■ n❑❑
■ nnn
❑ ❑■.❑
Yes No NA NE
❑ ■❑❑
■ ❑ 0 ❑
n ❑❑■
■ nnn
•oo❑
Page # 4