Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG550768_Regional Office Historical File Pre 2018 (2)
3" Environmental Quality ' Mr. Harold Hope 3811 Bonwood Drive Charlotte, NC. 28211 ROY COOPER Governor F�Lm, AEL S. REGAN 4= Secretary S. JAY ZIMMERMAN Director August 3, 2017 Subject: Compliance Evaluation Inspection 123 Langdon Road/Mooresville Certificate of Coverage No. NCG550768 Iredell County Dear Mr. Hope: Enclosed is a copy. of the Compliance Evaluation Inspection Report for the inspection conducted . at the subject facility on August 1, 2017,.by.Mr. Wes Bell of this Office. Should you have any questions concerning this report, please do not hesitate to contact Mr. Bell at (704) 235-2192, or via email at wes.bellna,ncdenr.goy. Sincerely, W. Corey Basinger, Regional Supervisor Water Quality. Regional Operations Section Division of Water Resources, NCDEQ. Enclosure: Inspection Report cc: Iredell County Health Department MSC-1617 Central -Basement WB Mooresville Regional office Location: 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-16991 Fax: (704) 665-60401 Customer Service:1-877-623-6748 + Internet: www.ncwaterquality.org United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8 31-98 Section A: National Data System Coding (Le., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 iti i 2 15 I 3 I NCG550768 I11 12 17/08/01 17 18 L,j 19 I c I 201 211 I l I. I I I l l III 11 I I I I I I I I I I I I I I I I I I I I -I I I I I I I J 166 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved --- 67 1.0 70 I, I 71 -! 72 LNJ 73.I 74 75 80 Section B: FacilityData Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit.Number) 10:49AM 17/08/01 13/08/01 123 Langdon Road 123 Langdon Rd Exit Time/Date Permit Expiration Date Mooresville NC 28117 10:57AM 17/08/01 18/07/31 Name(s) of Onsite Representative(s)MUes(s)/Phone and Fax Number(s) Other Facility Data Gerald' Hingst/Y - Name, Address of Responsible OfficiaUritle/Phone and Fax Number Contacted Harold Hope,3811 Bon wood Dr Charlotte NC 28211/Owner// � Yes Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenartct: Facility Site Review Section D: Summary of Finding/Corriments (Attach additional sheets of`narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) f lnspe r(s) Agency/Office/Phone and Fax Numbers Date Wes Bell- MRO WQ/f104-663-1699 Ext.2192/. Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W. Corey Basinger MRO WQ//704-235-2194/ EPA Form 3560-3 (Rev 9-94) Previous editions are. obsolete.- Page# NPDES yr/mo/day Inspection Type 1 31 NCG560768 I11 12 17/08/01 17 18 I j r Section D: Summary of Finding/Comments .(Attach additional sheets of narrative and checklists as necessary) Page# 2 r Permit; NCG550768 Owner - Facility: 123 Langdon Road Inspection Date: 08/01/2017 Inspection Type: Compliance Evaluation Permit Yes No NA NE i (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑ application? Is the facility as described in the permit? 00 ❑ ❑ # Are there any special conditions for the permit? ❑ ❑ 0 ❑ Is access to the plant site restricted to the general public? ❑ ❑ N ❑ Is the inspector granted access to all areas for inspection? "❑ ❑ ❑ Comment: The last compliance evaluation inspection was Performed on 8/11/15 by DWR staff. The Permittee has kept the permit active: however, the residence continues to be served by a conventional subsurface system with no discharges to surface waters This conventional system has been able to treat the wastewater currently being generated by the single tenant Currently residing in the house. There are no current plans to install a treatment system to discharge into surface waters. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: No evidence of Ponding or:discharges to surface waters were observed from the conventional subsurface wastewater treatment system during the on -site inspection 5 Page# 3 Emdronmentcal Quality October 27, 2015 Mr. Harold Hope, Owner 3811 Bonwood Dr. Charlotte, NC 28211 PAT MCCRORY Governor DONALD R. VAN DER VAA.RT .. seecetary ,•I� _ r Subject: Compliance Evaluation Inspection 123 Langdon Rd. Certificate of Coverage No. NCG550768 Iredell County Dear Mr. Hope: Enclosed is a copy of the Compliance Evaluation Inspection for the inspection conducted at the subject facility on October 16, 2015 by Mr. Ori Tuvia. As was discussed in letter that was sent by Mr. John Hennessey on August 14, 2015 annual fees for the years 2012, 2013, and 2014 are due. If you don't wish to continue the permit please send a request for it to be rescinded addressed to Mr. Hennessey to: 1617 mail service center, Raleigh, NC 27699-1617 The attached report, should be self-explanatory; however, should you have any questions, please do not hesitate to contact Mr. Tuvia at (704) 235-2190, or via email at ori.tavia@ncdenr.gov. Since ly, P 61� Michael Parker, Regional Supervisor Water Quality'Regional Operations Section Mooresville Regional Office, DWR Enclosure: Inspection Report CC: MSC 1617- Central files/Basement Iredell County Health Department . !"-1"Noih�ng;�vmpares�.L.. . .. Stets.ofPioriflCur6luu.($r..viivrmicm2al4ualrty: . . T6p1 �}jif$CIV)tt!�Efster I.RafE'MjhiNMi)I(•3R)fiiTJ'?lfi'1_``.)•lr.(11. . United Slates Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 IS 1 3 I NCG550768 I11 121 15/10/16 I17 181,•1 191 c I 201 211IIIII IIIIIII11II IIIIIII I I I I I I I I I I I I I I I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 CIAReserved 67 1.0 70 I I 71 I n, I 72 � n, L—I L_I 731 I 174 75 I I I 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 11:55AM 15/10/16 13/08/01 123 Langdon Road 123 Langdon Rd Exit Time/Date Permit Expiration Date Mooresville NC 28117 12:05PM 15/10/16 18/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Harold Hope,3811 Bonwood Dr Charlotte NC 28211/// No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenance Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Or! A Tuvia MRO WQU704-663-1699/ Sign ure ana ment Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type 1 31 NCG550768 I11 12 15/10/16 17 18 ICI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# Permit: NGG550768 Inspection Date: 10/16/2015 Owner - Facility: 123 Langdon Road Inspection Type: Compliance Evaluation Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: The facility has not been constructed, there is no discharge. Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to ail areas for inspection? Yes No NA NE ❑ ❑ M ❑ ❑ ❑'E ❑ Yes No NA NE ❑ ❑ N ❑ ❑ ❑ ■ ❑ ❑ ■ ❑ ❑ ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ Comment: The permitee has asked for the permit to be rescinded in 2011. in 2012 asked for the permit to be reinstated, the permitee had not made any annual fee renewal payments for the past 3 years. Page# 3 0OS--11L�0 (53 - - ° O - - - m co Ct) o C! t N ;Mu 0 laj,--Jt C)� 3g1� -7.Z�q- -36q-- 31� NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality -Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary August 19, 2011 Certified Mail Return Receipt Requested 70081140 0002 27161534 Ms. Jane Hope 3811 Bonwood Drive Charlotte, NC 28211 Subject: NOV-2011-PC-0473 _.,Notice of Violation Compliance Evaluation Inspection 123 Langdon Rd NPDES General Wastewater Permit NCG550768 Iredell County, North Carolina Dear Ms. Hope: Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection conducted at the subject facility on August '2, 2011, by Ms. Donna Hood of this Office. This report is being issued as.a Notice of Violation'(NOV) because of the violations of the subject NPDES permit and North Carolina General Statute (G.S.) 143-215.1 as detailed in the Permit Section of the attached report. Pursuant to G.S. 143-215.6A, a civil. penalty of not more than twenty five -thousand dollars (25,000.00) per violation per day may be assessed against any person who violates or fails to act in accordance with the terms, conditions, or requirements of any permit. issued pursuant to G.S. 143-215.1. On the day of the inspection, Mrs. Sandy Salle, was available for the inspection. As previously discussed with Mrs. Salle, the site has a single family wastewater discharge permit with the Division of Water Quality. At this point, it is unclear whether the site still needs to retain the permit. Permitting fees have not been paid since 2007. If this permit is not necessary, please submit a letter requesting that the permit be rescinded. The request for rescission should be sent to the following address: Mooresville Regional Office Location: 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-16991 Fax: (704) 663-60401 Customer Service:1-877-623-6748 Internet: vnNVv.ncwaterquality.org An Equal Opportunity 1 Affirmative Action Employer — 50% Recycled110% Post Consumer paper One Nor(11Carolina fi ll.J-Itdi. Mrs. Jane Hope NOV-2011-PC-0473, page 2 August 19, 2011 Attn: Mr. John Hennessy NC Division of Water Quality Surface Water Protection Compliance & Expedited Unit 1617 Mail Service Center Raleigh, NC 27699-1617 In the request for rescission, please include the following pertinent information: 1. You have not installed the discharge system 2. You do not need to install the discharge system 3. You requestforthe permit to be rescinded If the permit is still required, please submit the overdue amount with the enclosed invoices to the address on the invoices. It is requested that a written response to the inspection be submitted to the Division of Water Quality/Mooresville Regional Office discussing whether the permit will be rescinded or the annual permit fees will be paid by September 2, 2011. In responding, please address your comments to the attention of Ms. Marcia Allocco. Actual fees or permit rescission request should be submitted to the Raleigh address. This report should be self-explanatory; however, should you have any questions concerning the report, please do not hesitate to contact Ms. Hood or me at (704) 663-1699. Sincerely, 4-U� Robert B. Krebs Surface Water Protection Regional Supervisor Enclosure --- - __ — — - — - _- DH NCDENR North Carolina Department of Environment and. Natural Resources - Pat McCrory Donald. R. van der Vaart Governor Secretary August 14, 2015 RECEIVEDINCDENRlDWR CERTIFIED MAIL 7013-2630-0001-8998-2564 - S E P 1 0- 2015 RETURN RECEIPT REQUESTED_ WQR08 Mr. Harold Hope MOORESVILLE REGIONAL OFFICE 3811 Bonwood Drive Charlotte, NC 28211 Subject: Past Due Annual Fees . NPDES Permit NCG550768 123 Langdon Road: Iredell County .Dear Mr. Hope: A review of the Division's'billing records indicates that your Annual Administering and Compliance Fees for the above -referenced permit have not been paid. This fee requirement is documented in your currently active permit, Part II Section B. 12 [General Permit NCG550000, p. 9]. . Your annual fees are due on the anniversary. of your original permit effective date (November 17, 1995). There was an error in our database that resulted in no annual fee invoices being generated and mailed since the year 2010. ' The Division is waiving fees for the year 2011 ($60). Thus, unpaid invoices for years 2012, 2013 and 2014 are past due and payable. The total amount dire. is $180. I have attached copies of the unpaid invoices for your review. Please see payment invoices for payment instructions. Failure to pay the fee in a timely manner in accordance with 15A NCAC 02H .0105(b)(2).may cause this Division to initiate action to revoke the permit: If you have questions about this matter, or if you have evidence that these fees have already been paid, please contact Derek Denard at.[derek.denard@ncdenr. ov] or.call (919) 807-6307. incer y, ohn Hennessey Division of Water Resources, NCDENR hc: Enclosures: 2015PR003577, 2015PR0036191 2015PR003655 cc: NPDES Files ®Iff Q'Regional Operations Files 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-63001 Fax: 919-807-64921Customer Service: 1-877-623-6748 Internet:: www.ncwater.om An Equal OpportunityWfirmative Action Employer RECEIVED DIVISION CDF VVZNT'E: QUALITY AUG 2 6 2013 NCDENR JLL FS'N ►�iOOP.ES'ViLLC r;�C!':sr�;AL OFFICE North Carolina Department of Environment and Natural Resources Division of Water Resources Pat McCrory, Governor Thomas A. Reeder, Director John E. SkV'Ma)h1,/SJe'cretaryn August 20, 2013 qU A, f�;. �z013 ��Af ] l I "' " r w: Harold Hope ;�,.3,(1 �'�;,r , Hope Children's Trust r Ff �•`... , Ill(,y" , 3811 Bonwood Dr Charlotte, NC 28211 Subject: Transfer of coverage / General Permit NCG550000 123 Langdon Road Certificate of Coverage NCG550768 Iredell County Dear Permittee: The Division has reissued General Permit NCG550000. Therefore, the Division is hereby renewing your Certificate of Coverage (CoC) to discharge under NCG550000. This CoC is issued pursuant to the requirements of North Carolina General Statue 143-215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated October 15, 2007 [or as subsequently amended]. A copy of the renewed General Permit is also attached. If any parts, measurement frequencies or sampling requirements contained in this General Permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, the certificate of coverage shall be final and binding. Please take notice that this Certificate of Coverage is not transferable except after notice to the Division. The Division may require modification or revocation and reissuance of the certificate of coverage. Contact the Mooresville Regional Office prior to any sale or transfer of the permitted facility. Regional Office staff will assist you in documenting the transfer of this CoC. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Actor any other Federal or Local governmental permit that maybe required. If you have any questions concerning the requirements of the General Permit, please contact Charles Weaver of the NPDES staff [919 807-6391 or charles.weaver@ncdenr.ggov]. cerely, for Thomas A. Reeder cc: Mooresville Regional Office / Surface Water Protection NPDES file--- - -- - 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 One 512 North Salisbury Street, Raleigh, North Carolina 27604 NorthCaro,'�„ a . Phone: 919 807-6300 /FAX 919 807-6489 I Internet: www,ncwaterquality.org An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper Aaturallff STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NCG550000 CERTIFICATE OF COVERAGE NCG550768 DISCHARGE OF DOMESTIC WASTEWATER FROM SINGLE FAMILY RESIDENCES AND OTHER 100% DOMESTIC DISCHARGES WITH SIMILAR CHARACTERISTICS UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Harold Hope Hope Children's Trust is hereby authorized to discharge domestic wastewater [<1000 GPD] from a facility located at 123 Langdon Road Mooresville Iredell County to receiving waters designated as Lake Norman, a class WS-IV & B CA stream in subbasin 03-08- 32 of the Catawba River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This certificate of coverage took effect August 1, 2013. This Certificate of Coverage shall remain valid for the duration of the General Permit. Signed this day August 20, 2013 for T as A. Reeder, Director vision of Water Quality By Authority of the Environmental Management Commission NCDENR North Carolina Department of Environment and Natural. Resources Beverly Eaves Perdue, Governor Harold Hope Hope Children's Trust 3811 Bonwood Dr Charlotte, NC 28211 Dear Permittee: Division of Water Quality Charles Wakild, P.E., Director August 10, 2012 Dee Freeman, Secretary RECEIVED DIVISION OF WATER QUALITY AUG 2 0 2012 Svvp SEC+ at — I'd MOORESVILLE REGIONAL OFFICE Subject: Renewal of coverage / General Permit NCG550000 123 Langdon Road Certificate of Coverage NCG550768 Iredell County In accordance with your renewal application [received on July 31, 2012], the Division is renewing Certificate of Coverage (CoC) NCG550768 to discharge under NCG550000. This CoC is issued pursuant to the requirements of North Carolina General Statue 143-215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated October 15, 2007 [or as subsequently amended]. If any parts, measurement frequencies or sampling requirements contained in this General Permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, the certificate of coverage shall be final and binding. Please take notice that this Certificate of Coverage is not transferable except after notice to the Division. The Division may require modification or revocation and reissuance of the certificate of coverage. Contact the Mooresville Regional Office prior to any sale or transfer of the permitted facility. Regional Office staff will assist you in documenting the transfer of this CoC. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning the requirements of the General Permit, please contact Charles Weaver of the NPDES staff [919 807-6391 or charles.weaver@ncdenr.gov]. 711:C1 I for Charles Wakild, P.E. cc: Mooresville Regional Office /Surface Water Protection 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 One 512 North Salisbury Street, Raleigh, North Carolina 27604 NorthCarohna Phone: 919 807-6300 / FAX 919 807-6489 / Internet: www.ncwaterquality.org Naturally An Equal Opportunity/Affirmative Action Employer - 50% Recycled/10% Post Consumer Paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NCG550000 CERTIFICATE OF COVERAGE NCG550768 DISCHARGE OF DOMESTIC WASTEWATER FROM SINGLE FAMILY RESIDENCES AND OTHER 100% DOMESTIC DISCHARGES WITH SIMILAR CHARACTERISTICS UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Harold Hope Hope Children's Trust is hereby authorized to discharge domestic wastewater [<1000 GPD] from a facility located at 123 Langdon Road Mooresville Iredell County to receiving waters designated as Lake Norman, a class WS-IV & B CA stream in subbasin 03-08- 32 of the Catawba River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This certificate of coverage shall become effective August 10, 2012. This Certificate of Coverage shall remain valid for the duration of the General Permit. Signed this day August 10, 2012 for Chtsiosin Wakild, P.E., birector D' of Water Quality By Authority of the Environmental Management Commission NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Govemor Director Secretary August 31, 2011 Mrs. Jane Hope 3811 Bonwood Dr Charlotte, N.C. 28211 Subject: Rescission of NCG550768 Dear Mrs. Hope: Division staff has confirmed -that the subject Certificate of Coverage is no longer required. Therefore, in accordance with your request, NCG550768 is rescinded, effective immediately. If in the future you wish to discharge wastewater to the State's surface waters, you must first apply for and receive a new NPDES permit. Discharge of wastewater without a valid NPDES permit will subject the responsible party to a civil penalty of up to $25,000 per day. If you have questions about this matter, please contact Charles Weaver of my staff at the telephone number or address listed below. Sincerely, r Coleen H. ul ins cc: Mooresville Regional Office 1 Donna Hood 1 NPDES Permit file Fran McPherson, DWQ Budget Office 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 512 North Salisbury Street- Raleigh, North Carolina 27604 Internet: hftp://portal.ncdenr.org/web/wq Phone: 919-807-6391 / FAX 919 807-6495 chades.weaver@ncdenr.gov An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper NorthCarohna Natzmally' i IFWA IWry Postage $ CertiFled Fee " ll6� rk Retum Receipt Fee N Here (Endorsement Required) Restricted Delivery Fee (Endorsement Required) T" MS JANE HOPE ser 3811 BONWOOD DRIVE -R CHARLOTTE NC 28211 ............. orF 6 96F, city" ��Lq•2�CI •------••-- Certified Mail Provides: ■ A mailing receipt ■ A unique Identifier for your mailpiece ■ A record of delivery kept by the Postal Service for two years Important Reminders: . ■ Certified Mail may ONLY be combined with First -Class Mail® or Priority Mail ■ Certified Mail is not available for any class of international mail. ■ NO INSURANCE COVERAGE IS PROVIDED with Certified Mail. Fc valuables, please consider Insured or Registered Mail. ■ For an additional fee, a Return Receipt may be requested to provide proof o delivery. To obtain Return Receipt service, please complete and attach a Retun Receipt (PS Form 3811) to the article and add applicable postage to cover thi fee. Endorse mailpiece "Return Receipt Requested". To receive a fee waiver fo a duplicate return receipt, a USPS® postmark on your Certified Mail receipt i; required. ■ For an additional fee, delivery may be restricted to the addressee c addressee's authorized agent. Advise the clerk or mark the mailpiece with th endorsement 'Restricted -Delivery". ■ If a postmark on the Certified Mail receipt is desired, please present the arti cle at the post office for postmarking. If a postmark on the Certified Ma receipt is not needed, detach and affix label with postage and mail. IMPORTANT- Save this receipt and present it when making an Inquiry. PS Form 3800, August 2006 (Reverse) PSN 7530-02-000-9047 FIL'E/ C. North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor Certified Mail Return Receipt 12eguested 7008 1140 0002 2716 1534 Ms. Jane Hope 3811 Bonwood Drive Charlotte, NC 28211 Dear Ms. Hope: Diu -slop o Wa er Quality Coleen H. Sullins Director August 19, 2011 Subject: NOV-2011-PC-0473 Dee Freeman Secretary Notice of Violation Compliance Evaluation Inspection 123 Langdon Rd NPDES General Wastewater Permit NCG550768 Iredell County, North Carolina Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection conducted at the subject facility on Augusi'2, 2011, by Ms. Donna Hood of this Office. This report is being issued as a Notice of Violation (NOV) because of the violations of the subject NPDES permit and North Carolina General Statute (G.S.) 143,215:1 as 'detailed in the Permit Section of the attached report. Pursuant to G.S..143=215.6A, a civil penalty of not more than twenty five -thousand dollars (25,000.00) per violation per day may be assessed against any person who violates or fails to act in accordance with the terms, conditions, or requirements of any permit issued pursuant to G.S. 143-215.1. - On the day of the inspection, Mrs. Sandy Salle, was available for the inspection. As previously discussed with Mrs. Salle, the site has a single family wastewater discharge permit with the Division of Water Quality. At this point, it is unclear whether the site still needs to retain the permit. Permitting fees have not been paid since 2007. If this permit is not necessary, please submit a letter requesting that the permit be rescinded. The request for rescission should be sent to the following address: f Mooresville Regional Office Location: 610 East Center Ave., Suite 301 Mooresville, NC 28115 Phone: (704) 663-16991 Fax: (704) 663-60401 Customer Service:1-877-623-6748 One Internet: whn;i.ncLvaterquality.org I° offliCarolina at An Equal Opportunity 1 Afarmalive Action Employer — 50% Recyded110% Post Consumer paper ". j p €rJ u ...ant.:�t'L� i NOV-201 ? P e 3 -august 19, 2011 Attn: Mr. John Hennessy NC Division of Water Quality Surface Water Protection Compliance & Expedited Unit 1617 Mail Service Center Raleigh, NC 27699-1617 In the request for rescission, please include the following pertinent information: 1. You have not installed the discharge system 2. You do not need to install the discharge system 3. You request for the permit to be rescinded If the permit is still required, please submit the overdue amount with the enclosed invoices to the address on the invoices. It is requested that a written response to the inspection be submitted to the Division -of Water Quality/Mooresville Regional Office discussing whether the permit will be rescinded or the annual permit fees will be paid by September 2, 2011. In responding, please address your comments to the attention of Ms. Marcia Allocco. Actual fees or permit rescission request should be submitted to the Raleigh address. This report should be self-explanatory; however, should you have any questions concerning the report, please do not hesitate to contact Ms. Hood or me at (704) 663-1699. Sincerely, -C-70--e- Robert B. Krebs Surface Water Protection Regional Supervisor Enclosure DH 0 Untied States Envircnnnentai F-ctection Agency corm Accraved. Washington, D.C. 20�60 OMB \to. 2040-0057 /� E PA Watel- Compliance Inspection Report A.pprovai expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection 'Type Inspector FacType - 1 1 NI 2 151 31 NCG550768 1 11 121 11/08/02 117 181 OI 191 sI 201_1 Remarks 2111111111111111111111111IIIIIIIIIIIIIIIIIIIIIIII Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA - --- ---- ---Reserved---- — -- - 671 4.0 169 701 1 71 1_1 721 NJ 73 LLJ 74 751 1 1 1 1 1 1 1 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 11:00 AM 11/08/02 02/08/01 123 Langdon Road Exit Time/Date Permit Expiration Date 123 Langdon Rd Mooresville NC 28117 11:30 AM 11/08/02 07/07/31 Name(s) of Onsite Rep resentative(s)/Titles(s)/Phone and Fax Numbers) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Jane Hope,3811 Bonwood Dr Charlotte NC 28211//704-364-1828/ No Section C. Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenance M Records/Reports Self -Monitoring Program Facility Site Review Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) _ Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers. Date Donna Ho d MRO WQ//704-663-1699 Ext.2193/ . Signature of Management Q A Revie er Agency/Office/Phone and Fax Numbers Dat !! ` M rcia occo MRO WQ//704-663-1699 Ext.2204/ EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPIDES yrfmo/day Inspection Type 3 NCG550768 I11 12 11/08/02 1 17 18 lCl h 0 l Page # 2 Permit: NCC550768 Inspection Date: 08/02/2011 Owner -.Facility: 123 Langdon Road Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? n a n fL Is the facility as described in the permit? ❑ ! # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? n n n Is the inspector granted access to all areas for inspection? n n n Comment: The permittee has not maintained compliance with the permitting fees. Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? ❑ ❑ ' Does the facility analyze process control parameters, for ex: MLSS, MCRT,. Settleable Solids, pH, DO, Sludge n n n Judge, and other that are applicable? Comment: ' The type of system available at the site was unknown. The current renter has been instructed to pump out the septic tank every three months because of the condition of the current wastewater treatment system. Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? n n n Is all required information readily available, complete and current? n Cl n Are all records maintained for 3 years (lab. reg. required 5 years)? n ❑ ❑ t Are analytical results consistent with data reported on DMRs? n n n Is the chain -of -custody complete? n n n - Dates, times and location of sampling LEI Name of individual performing the sampling Results of analysis and calibration f Dates of analysis Name of person performing analyses Transported COCs i Are DMRs complete: do they include all permit parameters? ❑ ❑ ❑ Is i IHas the facility submitted its annual compliance report to users and DWQ? n n 00 (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift?. n n n Is the ORC visitation log available and current? n ❑ o o Is the ORC certified at grade equal to or higher than the facility classification? n n ❑ Is the backup operator certified at one grade less or greater than the facility classification? i n n n ti Page # 3 - Permit: NCG550768 Owner - Facility: 123 Langdon Road inspection Date: 08102/2011 Inspection Type: Compliance Evaluation Yes No NA NE Record Keeping is a copy of the current NPDES permit available on site? ❑ in ❑ ❑ Facility has copy of previous year's Annual Report on file for review? ❑ n ❑ Comment: No records have been made available for review. Numerous phone calls to the land owner, Jane Hope, have gone unreturned. Page # 4 ■ Complete items 1, 2, and 3. Also complete item 4 if Restricted Delivery Is desired. 0 Print your name and address on the reverse so that we can return the card to you. Attach this card to the back of the mailpiece, or on the front if space permits. Article Addressed to: )811`130NWOQD,,DRIVE, :HARLOTTE, .'NC ,28211 ` "• ''' 4' A. -Signature ❑ Agent ❑ Addressei ecei by (Prf me) C. pate of Delivers D. s delivery ad ress die m item 1? ❑ Yes If YES, enter delivery address below: ❑ No 3 Service Type Certified Mail ❑ Express Mail Registered ❑ Return Receipt for Merchandise ❑ Insured Mail ❑ C.O.D. .,. 4. Restricted Delivery? (Extra Fee) ❑ Yes 7008 1140 0002 2716 1534 G Form 3811. February 2004 '. I ; Domestic Return Receipt tnssas-naM'itia UNITED STATES POSTAL SERVICE First -Class Mail Postage & Fees'P�id LISPS Permit No. G-10 • Sender: Please print your name, address, and ZIP+4 in this box •., a < LL. C� NCDENR/DWQ ,SURFACE WATER PROTECTION L>LU o , 610 EAST CENTER AVENUE !& SUITE 301 1A MOORESVILLE NC 28115 0 Eli v 0 il,lsi,„l_,i,l,l,i,,,!it l,i,i„l,i,,,Fii,l Property Data Page 1 of J 0 Iredell County Property Data Parcel Number: 4627502633.000 Inquiry Date: 8/2/2011 Disclaimer: While every effort is made to keep information provided over the internet accurate and up-to-date, the County does not certify the authenticity or accuracy of such information. No warranties, express or implied, are provided for the records and/or mapping data herein, or for their use or interpretation by the User. Tax Account Number: 000077373870 Old Parcel Number: 1702L02000A396 Owner Name: WILLIAM R CULP JR TRUSTEE FOR Mailing Address: C/O HAROLD HOPE TRUSTEE NEW YORK NY 101280000 Property Location: LANGDON RD Lot Number: 396 Legal Description: CRESCENT LAND+TIMBER CORP S8 P615-74 Municiple information n Township Code: 17 City Code: 00 httuJ/web2.mobile311.com/IredellReDolt/ret)oit.asi)x?PIN=4627502633.000 8/2/2011 Prope�-ry Data Page 2 of 2 v Neighborhood Code: 17226 Fire Code: unavailable Value InforMation - Current. Year Ta.N Card. Building Value: 141970 Other Building Features: 5570 Land Value: 340000 Fair Market Value: unavailable Tax Assessed Value:487540 Deferred: 0 Land Information - Register_of Deeds Online Search Date Recorded Document Type Deed Book Deed Page 19940816 WD 926 1306 Tax Information Exemption Tax Code 1 Tax Code 2 C FR04 Plat Book & Page Land Area Land Type Zoning 15-74 0.72 AC RR Tax Code 3 Tax Code 4 Tax Code 5 SW Iredell County 704.878.3118 Harmony 704.878.3118 Love Valley 704.878.3118 City of Statesville 704.878.3575 Town of Troutman 704.528.7600 Town of Mooresville 704.662,7040 Village of Davidson 704.892.7591 �httna/weh?..mnhile�l 1 _cnm/TredellRennrt/rennrt.acnx?PTN=469.7502633.000 8/2/2011 (Page 1 of 2) - C - _`�yt�.�sPr� cos . �. • 903 FILED -IREDELL. C-UNIT"" i �11 jtic 15 Pi.l2: 1,9 r • i 1 i, ' Exelse lthx $0. 00 Reeording'rime. Book and Page Tax Lot No. _--_._._....._...Parcel Identifier No.� Verified by __. _.County an the._._., _— day of by, de L.L-C., Trade St. Ste_ 1 Culp Elliott & Ca enter P 227 W. 1500 Mail after recording to_..._... — _�—�._�_._ _.�..._._._._:.._......_ it F Chatlottey NC 28202 This iristrumentwas prepared by,CUlp Elliott & Carpenter: P.L_L.C. 1 Brief description for the Index ILT 396,sEC 8, I 4 NORTH CAROLINA G1'NERAL WARRANTY DEED THIS DEED made this _._15th_••day of.._...._ _ _._�__ ..�_?ulk'_, 1021...._., by and between GRANTOR William R. Culp, Jr. Trustee for the Harold P_ Hope, Jr. and wife, Hope Childrens Irrevocable GST Trust U/A/D 12-10-93 Jane W. Hope C/o William R. Culp, Jr. 227 West Trade Street, Suite 1500 - Charlotte, NC 28202 i Enter to appropriate Mock for each party; -awe, addrew. and, it appropriate, character of entity, e.q. corporation or partnenhlp• The designation Grantor and Grantee as used herein shall include said parties, their heirs, successors, and assigns, and t shall include singular, plural, masruline, feminine or neuter as required by context. WITNESSETH, that the Grantor, for a valuable consideration paid by the Grantee, the receipt nt which is hereby aelmowledged, has and -by these presents does grant, bargain. sell and convey unto the Grantee in fee simple, all that __ __..._—.-__.__...._. ___ certain lot or parcel of land situated in the City Davidson Township, i Iredell _,—_ County. North Carulina and mare particularly described as foll..ws: BEING Lot 396, in section 8, as shown on map recorded in Map Book 15, at Page 74 in the office of the Register of Deeds for Iredell County AND BEING a part of the property conveyed to Crescent Land and Timber Corp. by deed of Duke Po ter Company recorded in Book 4$2, Page 91 in the office of the Register of Deeds for said County. A title search was not performed by the deed preparer. H.C. Bar Association Form No. L-3, ° 1976, Revised 0 1977 v" standard ra— taa Ewen epprares jo:ulr r/ trs W. C. car'aaeaetltl= and The ■. C. lee9r1ati= ct etaltone. 7. ..... ..... a.. _.. ._ b ... o n.e . _...V Book 926. Paae 1306. File Number (Page 2 of R) M The property hereinabove described was -acquired by Grantor by instrument recorded in Hook 692.. Page 788 in the Iredell County Public Registry A map ehotvinit the above described property is recorded in 14aP Book 15. Page 7�1 TO HAVE AND TO HOLD the aforesaid lot or parcel of land and all privileges and appurtenances thereto belonging to the Grantee in fee simple. And the Grantor covenants with the Grantee, that Grantor is seized of the premises in fee simple, has the right to convey the some in fee simple.. that title is marketable and free and clear oiall encumbrances, and that Grantor will warrant and defend the title against the lawful claims of all persons.whomsoever except for the exceptions hereinafter stated. Title to the property hereinabove described is subject to the following exceptions: 1. All valid and enforceable easements_, restrictions and rights -of -way of record, including the lien for'1994 ad valorem taxes not yet due and payable, the obligation for.the payment of which is hereby assumed by Grantee. 2. Deed of Trust executed by Harold P. Hope, Jr. and Jane 11. Hope to Frank R. Thies, Jr., Trustee for Thies. Realty and Mortgage Company recorded November 17, 1903 in Book. 553, Page 72 in. the Iredell County 'Public Registry, securing $112,500.00. IN WITNESS WHEREOF. the Grantor has hereunto set his hand and seal, or it corporate, has ..used this instrument to he signed to Us r otPOnt! name by Its duly authortard officers and its seal to be hertunto affixed by authority of it. 9oard or Directors. the day and Year tint Wo►e.amten. .................................................. ............ i .. v - ' -----------------------.(SEALf tcorponte Names 7 Harold P. Hope, J� p- By:------------ _......................... ................... 1 Y - ...... ...(SEAL) ............................ .. ATTEST: i • a>Li• •Near ..._. __-_-.(SEAL) __._.__.i e w Hope .................y:......:.c6tertiary (Corporate Seat) r' ........ ............................. (SEA W SEAL-STaridP• ., ; s NORTH CAROLINA. ....... fkgkleA. 113:2..._...__.. County. Y.t. a Notary PObtir of the County and State aforesaid. certify that H_.scoldP. ....... Hope,,•J_,-_an¢_______ r. •� 'wife,..Jane_ Yl...>39Pe...... ............... Gnptor, . •.'•W pecsopally appeared before me this day and acknowledged the execution of the foregoing IhsttumtnL Witnns toy •--,•�'-..,...••-�.�-s :.-. �' �'6aud and official stamp or seat. this �/._._ dal of .f• __.... _... 19�'F . _ • - � c: .::__ � . Lly Cunr,sion Expires June 15, 1�15�/i,, ....__. ._..-....._ Notary Public My commissioo expires: .......... .............. SEAL-STA39F NOETR CAROLn7A................................... County. 1. a Notary Public of the County and State afofeuld, certify that .......................................... x Personanr came before me this day and acknoveledSed that ..__ he It ........................... Serreta67 of .= a, ...'..... ............... .............._........ a North r.irpnna cofpwall..' San 'nat by a tu.My only 0 .O given and as the act of the Corporation, the foregoing instrument was sigped In it, name by. Its ............... President. stated with IN corporate seal and atirit" by ........... n its ........................... Secretary. witness my hand and official stamp or seahthts .------ day of --------------------------- 1y._____-_. My comaltnion expires: ...................._........ ................... Notary Public 7the forejoing Clruticatets) o7 ._ .._ _ --- Islc=ter°nrd to be correct This Instrument and this renincate are duly repttered at the date and time an M the Hoot and Page uloRn on the Tint ys neof. dy/)� .. ._ . ................fir 1C...._...__.___....... RtGISTER or DEEDS FOR _.... _... ........... :Y}-_._.._....COUNTT By .. �/1�\ . �lV.....:t..l-:................_._._......t�4q.-Atslt4ue-Reg4ttr of Deede V 10 V.C. Bar Association Yosm floe L-3, ° 197i3f Revised ° 1977 SA �y� sate Standard sure w tahn ap)re,rd toic:ty ty„ A l Its e. C. 11—-��ticn sod t!e a- C. anxis, to of dealt-sw. to am or... e o a a o a a 1. 0 ■ —..... a... .vt�w. iAaes.gp- .i .. t...... .,R A+•1, V_.''v 3.,__v _ _ __... - ;1 ter® IN Book 926 . PanP 1.306 . Fi 1 P Nlrmhcar State of North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross Jr., Secretary Alan W. Klimek, P.E., Director July 26, 2002 JANE HOPE HOPE JANE & HAROLD - SFR 3811 BONWOOD DR CHARLOTTE, NC 28211 I A 11 1 A NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Subject: Reissue - NPDES Wastewater Discharge Permit Hope Jane & Harold - SFR COC Number NCG550768 Iredell County Dear Permittee: In response to your renewal application for continued coverage under general permit NCG550000, the Division of Water Quality (DWQ) is forwarding herewith the reissued wastewater general permit Certificate of Coverage (COC). This COC is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated May 9, 1994 (or as subsquently amended). The following information is included with your permit package: A copy of the Certificate. of Coverage for your treatment facility * A copy of General Wastewater Discharge Permit NCG550000 * A copy of a Technical Bulletin for General Wastewater -Discharge Permit NCG550000 Your coverage under this general permit is not transferable except after notice to DWQ. The Division may require modification or revocation and reissuance of the Certificate of Coverage. This permit does not affect the legal requirements to obtain other permits which may be required by DENR or relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law rule, standard, ordinance, order, judgment, or decree. Please note that effective January 1, 1999 the fees for all.permits issued by DWQ were changed. This changed the fee for your wastewater general permit coverage from a $240 fee paid once every five years to a yearly fee of $50. If you have not already been billed this year for the yearly fee, you will receive a bill later this year. If you have any questions regarding this permit package please contact Bill Mills of the Central Office Stormwater and General Permits Unit at (919) 733-5083, ext. 548 _;.,.,. Sincerely, ���''" JUL 3 I 2002 for Alan W. Klimek, P.E. cc: Central Files Stormwater & General Permits Unit Files Mooresville Regional Office 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone 919-733-5083 FAX 919-733-0719 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper ilN xy- NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES MOORESVILLE REGIONAL OFFICE' DIVISION OF WATER QUALITY June 16, 1999 Harold Hope 3811 Bonwood Drive Charlotte, North Carolina 28211 Subject: Wastewater Discharge Permit Harold Hope NPDES Permit No. NCG550000 Cert. of Coverage No. NCG550768 Iredell County, NC Dear Mr. Hope: . Our files indicate that the subject wastewater discharge permit was issued to Mr. Harold Hope for a wastewater discharge from the subject residence. The Mooresville Regional Office requests that you contact this Office if you do not have a copy of the subject permit, if a change in property ownership has occurred, or if you have any questions regarding -this matter. } Pursuant to conditions of North Carolina General Permit Number NCG550000, the following documentation must be kept and readily available for inspection for a period of at least three years: required maintenance activities relating to the wastewater treatment system ` yearly sample analyses results for the parameters listed on the effluent limifation/monitoring page of the permit required inspections of disinfection apparatus and septic tanks Please do not hesitate to contact Roberto Scheller at (704) 663-1699 if you have any questions. Sincerely, D. Rex Gleason, P.E. Water Quality Regional Supervisor '_\ cc: Iredell County Health Department rls 919 NORTH MAIN STREET, MOORESVILLE, NORTH CAROLINA 281 IS PHONE 704-663-1699 FAX 704-663-6040 AN EQUAL OPPORTUNITY /AFFIRMATIVE ACTION EMPLOYER - 50% RECYCLED/10% POST -CONSUMER PAPER State of North Carolina Department of Environment, Health and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary A. Preston Howard,. Jr., P.E., Jane&Harold Hope 3811 Bonwood Drive Charlotte, NC 28211 Dear Permittee: mAR ?,5 1999 A14' [DEHNR Director a_.,_ ..._ .. .. July. 21, 1997 Subject: Certificate of Coverage No. NCG550768 Renewal of� General Permit Hope, Jane & Harold- Residence Iredell County In accordance with your application for renewal of the subject Certificate of Coverage, the Division is forwarding the enclosed General Permit. This renewal is valid from the effective date on the permit until July 31, 2002. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215 .1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated December 6, 1983. If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, this Certificate of Coverage shall be final and binding. The Certificate of Coverage for your facility is not transferable except after notice to the Division. Use the enclosed Permit Name/Ownership Change form to notify the Division if you sell or otherwise transfer ownership of the subject facility. The Division may require modification or revocation and reissuance of the Certificate of Coverage. If your facility ceases discharge of wastewater before the expiration date of this permit, contact the Regional Office listed below at (704) 663-1699. Once discharge from your facility has ceased, this permit may be rescinded. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality, the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact the NPDES Group at the address below. Sincerely, i y A. Preston Howard, Jr., P.E. cc: Central Files 6 M'ooresvillLReg onaLOffice, NPDES Group Facility Assessment Unit P.O.Box 29535, Raleigh, North Carolina 27626-0535 (919):733-5083 FAX (919) 733-0719 p&e@dem.ehnr.state.nc.us An Equal Opportunity Affirmative Action Employer 50% recycled / 10% post -consumer paper STATE OF NORTH CAROLINA DEPARTMENT -OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG550000 CERTIFICATE OF COVERAGE NO. NCG550768 TO- DISCHARGE DOMESTIC WASTEWATERFROM SINGLE FAMILY RESIDENCES .AND .-OTHER DISCHARGESWITHSIMILAR CHARACTERISTICS UNDER THE, NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by. the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Jane&Harold Hope is hereby authorized to operate a wastewater treatment facility which includes a septic tank, sand filter and associated appurtenances with the discharge of treated wastewater from a facility located at Hope, Jane & Harold- Residence 123 Langdon Road Mooresville Iredell County to receiving waters designated as subbasin 30832 in the Catawba River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV of General Permit No. NCG550000 as attached. This certificate of coverage shall become effective August 1, 1997. This certificate of coverage shall remain in effect for the duration of the General Permit. Signed this day July 21, 1997. k. Preston HowardvJr., P.E., Director Division of Water Quality By Authority of the Environmental Management Commission State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director Ms. Jane W. Hope Mr. Harold P. Hope, Jr. 3811 Bonwood Drive Charlotte, North Carolina 28211 Dear Ms. Hope: aA74 � L7EHN1� N.C. DEPT. OF November 17, 1995 ENVIRONMENT, HEALTH, & NATURAL RESOURCES NOV 29 1995 ENVIRONMENTAL MANAGEMENT i.3VILLE REGIONAL OFFICE Subject: Permit Issuance/ Authorization to Construct Permit No. NCG550768 Hope Residence Iredell County In accordance with the application for discharge, the Division is forwarding herewith the subject Certificate of Coverage to discharge under the subject state - NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated December 6, 1983. The wastewater treatment plant as shown on the plans will violate the buffer requirement of 15A NCAC 2H .0219 0) (5) (J) (iv). The Division is granting a waiver to this requirement due to a letter from Frank E. Mangum, the affected property owner. If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such a demand is made, this Certificate of Coverage shall be final and binding. A letter of request for an Authorization to Construct was received June 19, 1995 by the Division and final plans and specifications for the subject project have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of a 360 gpd wastewater treatment system consisting of a 1500-gallon septic tank, a 1500-gallon dosing tank, a 25' by 12.5' recirculating sand filter, a tablet chlorinator, a chlorine contact tank with a 30 minute detention time, and a cascade aerator with discharge of treated wastewater into Lake Norman, a Class WS-IV B water in the Catawba River Basin. In addition, the system components must be located above the 100-year flood line on the property. This Certificate of Coverage shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NCG550000. Please take notice that this Certificate of Coverage is not transferable except after notice to the Division of Environmental Management. The Division of Environmental Management may require modification or revocation of the Certificate of Coverage. P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-0719 An Equal Opportunity Affirmative Action Employer . 50% recycled/ 10% post -consumer paper NCG550768 Hope Residence November 17, 1995 Page 2 The Mooresville Regional Office, phone no. (704) 663-1699, shall be notified at least forty-eight (48) hours in advance of operation of the installed facilities so that an in - place inspection ban be made. Such notification to the regional supervisor shall be made during normal office hours from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the NPDES Permit, this Certificate of Coverage and the approved plans and specifications. Mail the Certification to the Permits and Engineering Unit, P.O. Box 29535, Raleigh, NC 27626-0535. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the facility. The sand media of the sand filter units must comply with the Division's sand specifications. The engineer's certification will be evidence that this certification has been met. A leakage test shall be performed on the septic tank and dosing tank to ensure that any ex -filtration occurs at a rate which does not exceed twenty (20) gallons per twenty- four (24) hour per 1,000 gallons of tank capacity. The engineer's certification will serve as proof of compliance with this condition. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Environmental Management or permits required by the Division of Land Resources, Coastal Area Management Act, or any other Federal or Local governmental permits that may be required. If you have any questions or need additional information, please contact Mr. Jay Lucas, P.E., at telephone number (919) 733-5083, ext. 502. Sincerely, + Original Signed By David A. Goodrich A. Preston Howard, Jr., P.E. cc: Central Files ooresIV? 11 a to ignWater Quality edell County Health Department Permits and Engineering Unit STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL MANAGEMENT GENERAL PERMIT NO. NCG550000 CERTIFICATE OF COVERAGENO. NCG550768 TO DISCHARGE DOMESTIC WASTEWATERS FROM SINGLE FAMILY RESIDENCES AND OTHER DISCHARGES WITH SIMILIAR CHARACTERISTICS UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Jane W. Hope and Harold P. Hope, Jr. is hereby authorized to operate of a wastewater treatment facility that consist of a septic tank, recirculation sandfilter, chlorination, post aeration and associated appurtenances with the discharge of treated wastewater from a facility located at the Hope Residence 123 Langdon Road Mooresville Iredell County to receiving waters designated as Lake Norman in the Catawba River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This certificate of coverage shall become effective November 17, 1995 This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day November 17, 1995 Original Sighed By David X Goodrich A. Preston Howard, Jr., P.E., Director Division of Environmental Management By Authority of the Environmental Management Commission f '1- t, W%tb'AO_ \verplanx soo •tim -TO 0 x A., If kP f Cc, A 8 Creek 00, \.5c?77 � /�/\� �) 1, f �/( �', 1 • (ui..1 , :� \ ti .1 / (,� oil 71 t p 920 MI 0 o 1. la ts? A 7 K-1 8 N cp 'w W 800 d5 J( C. Ch r i lk Boat e• ll Ramp 1941 )6, `i% 864 e4;1 1 135 1 1 41 SOC PRIORITY PROJECT: No To: Permits and Engineering Unit Water Quality Section Attention: Jay Lucas Date: July 20, 1995 NPDES STAFF REPORT AND RECOMMENDATIONS County: Iredell NPDES Permit No.: NCC550769 MRO No.: 95-108 PART I - CENERAL INFORMATION 1. Facility and Address: Jane Hone Residence 3811 Bon..'ood Drive Charlotte,.N.C. 28211 2. Date of Investigation: July 20, 1995 3. Report Prepared By: Michael L. Parker, Environ. Engr. II 41 Person Contacted and Telephone Number: David Roberts, Applicants Engineer, (704) 857-3800. 5. Diiections to Site: From the jct. Of SR 1115 (McKendree Church Rd..) And SR 1457 (Digh Circle) in southwestern Iredell County, travel north on SR 1457 - 0.45 mile and turn right on L.angdon Rd.. (No SR number). The Hope residence is the third residence on the right side of Langdon Rd. (L.angdon, road i s .a dirt road) . 6. Discharge Point(s), List for all discharge Points: - Latitude: 350 3 ' 37'' Longitude: 800 55' 54" Attach a USCS Map Extract and indicate treatment plant site and discharge point on map. USCS Quad No.: E 15 SEA/ 7. Site size and exkansion.area consistent with application: Yes. Very limited area is available for expansion, if necessary. S. Topography (relationship to flood plain included): Hilly, 5- 15% slopes. The site is above the high water elevation of Lake Norman. 9. Location of Nearest Dwelling: Approx. 150 feet from the proposed WmTP site. Page Two 10. Receiving Stream or Affected Surface platers: Catawba River (Lame Norman) a. Classification: EPIC -IVY B b. River Basin and Subbasin No.: Catawba 030832 c. Describe receiving stream features and pertinent downstream uses: Primary and Secondary recreation with frequent bodily contact. There are no known drinking water intakes located in the immediate area. PART II - DESCRIPTION OF DISCHARCE AND TREATMENT WORKS 1. a. Volume of Wastewater: 0.00036 MCD (Design Capacity) b. What is the current permitted capacity: N/A C. Actual treatment capacity of current facilit},(current design capacity): N/A d. Date(s) and construction activities allowed by previous ATCs issued in the previous two years: N/A e. Description of existing or substantially constructed WWT facilities: The existing :sWT facilities consist of a septic tank followed by a nitrification field. f. Description of proposed ,rWT facilities: The applicant proposes to construct a recirculating sand filter treatment system consisting of a 1500 gallon capacity septic tank followed by a 1500 gallon capacity dosing/pumping tank, a recirculating sand filter bed, a 100 gallon chlorine contact tank, and cascade aeration. Possible toxic impacts to surface waters: Chlorine will be added to the waste stream. h. Pretreatment Program (POTWs only): Not Needed. 2. Residual handling and utilization/disposal scheme: Septage will be removed as needed by a septage hauler and disposed of at a location approved by the DEH. 3. Treatment Plant Classification: Less than 5 points; no rating (include rating sheet). Class I 4. SIC Code(s): 9999 Wastewater Code(s): 04 5. MTU Code(s): 45007 PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Crant. Funds or are any public monies involved (municipals only)? Iwo Page Three ?. Special monitoring or limitations .(including toxicity) requests: None at this time. ?. Important SOC/JOC or Compliance Schedule dates: N/A 4. Alternative Analysis Evaluation a. Spray Irrigation: Insufficient area. b. Connect.to regional sewer system: None available. c. Subsurface: Existing system has failed with no opportunity for repair. PART IV - EVALUATION AND RECOMMENDATIONS The applicant, Mrs. Jane Hope has applied for an NPDES permit to discharge wastewater from a SFR into Lake Norman (Catawba River). The existing residence is currently served by a septic tank/nitrification field, which is presently failing and there' -is no available area for repair. Off -Site repair has been evaluated, however, additional off -site repair area is currently unavailable. Faced with no other disposal option, Mrs. Hope is proposing to discharge into the Lake. The proposed facilities appear to he capable of complying with the suggested BPJ effluent limitations (BODS-15 mg/1, NH_3 as N-4 mg;1). There appears to be a buffer conflict between the location of the proposed EgWTP and the adjacent property line, however, we have no objection to the applicant obtaining a variance for the construction of the proposed .4WT facility provided concurrence is also obtained from the adjacent homeowner. Pending receipt and approval of the WLA, it is recommended that a Permit be issued as requested. Signature ofy port Preparer at r Yu v g Water n ual Regional onal u ervi sor Dat e c h; \dS_ ,dsr95\F.n: 5_ I Nili. M )0\ "818 05 t\I 6 epp 10 Ramp Creek Qj 4 h ry Creek • ,- MATING i. f SCALE FOR CLASSIFICATION OF WATER POLLUTION CONTROL SYSTEMS Name of Facility: -11/%/ owner or Contact Person: �iWr IV Alailing Address 38 Aaxj4J� 4' 1IVJ� A ai •�- zr pounty: - ���`l/ Telephone: O,f — � l 2- �resent Classification: AlK New FacilityL.—,� Existing Facility PDES Per. No.44GW-Nw5,078Nondisc. Per. No.WO Health Dept.Per No. Rated by: phone: 716r-6G3 -/( f? Date: 9� O Reviewed by: Health Dept. Telephone: Regional Office Telephone: Central Office Telephone: ®RC: _Grade : Telephone: heck Classification Subsu ce Spray Irrigation Land Applica 'on Wastewater Classification: (Circle One) I II III IV Total Points **cik all units that apply) septic tanks -wimp tanks siphon or Pwp-d=Mg systems sand filters grease trap/interceptor oll/waler separators gravity subsurface treatment and disposal: pressure subsurface treatment and disposal: SPRAY iRRIGATIt7N CLASSIFICATION (check all units that apply) 1. preliminary treatment (definition no. 32 ) 2- lagoons 3`_septic tanks ^ 4`_pump tanks 5. pumps S_sand filters 7—grease trap/iinteroeptor 8. oll/water separators 9.dWnfectlon 10.chemical addition for nutrienthdgae control 11. spray irrigation of wastewater In addition to the above classifications, pretreatment of wastewater In excess of these components shall be rated using the point rating system end will require an operator . with an appropriate dual certification. LAND APPLICATiONIRESIDUALS CLASSIFICATION (Applies only to permit holder) 1. Land apprication of biosolids, residuals or contaminated sails on a desipnaled site. WASTEWATER TREATMENT FACI I Y CLASSIFIt:AT10N The following systems shall be assigned a Class I classification, unless the flow is of a significant quantity or the technology is unusually complex, to require consideration by the Commission on a case -by -case basis: (Check I Appropriate) 1 Oil/water Separator Systems consisting only of physical separation, pumps and disposal; Septic TankSand Filter Systems consisting only of septic tanks, dosing apparatus, pumps,Nuw fillers, disinfection end direct discharge; 3. Lagoon Systems consisting only of preliminary treatment, lagoons, pumps, disinfection, necessary chemical treatment for algae or nutrient control, and direct discharge; 4. Ctosed-bop Rekycle Systems; $. Groundwater Remediation Systems consisting only of oiL water separators, pumps, air -stripping, carbon adsorption, disinfection and disposal; S.__Aquaculture operations with discharge to surface wafers; 7. _ Water Plant sludge handling and back -wash water. treatment; $.___Seafood processing consisting of screening and disposal. e. Singla-family discharging systems, with the exception of Aerobic Treatment Units, will be dassifwd I permitted after July 1, IM or I upon Inspection by the Division. It Is found that the system Is not being adequately operated or maintained. Such systems will be notified d the cimsification or reclassification by the Commission, In writing. The following scale is used for rating wastewater treatment facilities: (circle appropriate points). REM POINTS (2) (3) (4) (5) (a) ftdustrtel Pretreatment Units or hdustrial PM11matm0rt Program (see dsfkftn No.33).:.................................:t....:........A DESIGN FLOW OF PLANT IN plod (rot applicable to non•oontaminated cooing waters, sludge handing faeiUtiee (or twitter purifkatbn plants, totatiy dosed, cycle systems(sae definition No. 1t), and facilities consisting only of hem (4)(d) or items (4)(d) and (11)(d)) - 0 - 20,000............ «.:.».» ._.».».«._...»».........................._.._...:...».».......»...... ....... _.............. ......... 20.001 - 60.000.._._.»..............»_..:_.»..».....................»........................:.....»....._.......»»................. 60.001 - 100.000........ »_»»..... ...».»..._....:................................. ... ...................»»........................ 3 100.001 - 250,000........... ... ............................. :...................»..:»...».»_»........«....»..._..................A 260.001 - 500.000.. ............»........_... ... .............................. ..._.._»..».....................................6 600.001 - 1.000,000...»....»...»:................»..............»........».........»........»...»....».�..»....................a 1.000.001 - 2.000.000.:......... .. ........................�.���... m a ntarri................. um.ol . _._.__ ». 0 2,0D0,001 (and up) rate 1 point additional for each 200.000 Design Flow (gpd) . PREI.NANARY UJITSlPROCESSES (ses definition No32) (a) Bvsrnans...... »......... ............ »..»...».»..._:..»......................... ........... »....................... .......................... 1 or (b) Mechanical Screins, Static Screens or Comminuting Devices ..... ............. ................................ 2 (c) Orit Ranoval..... ..... ».»........................... .............................. .... ........ ................................................. 1 (d) or Mechanics! or Aerated Grit Remwal.......... .... .............................................................. .......................2 (e) Flow Massuring Device...». ....... .....»._..»».._......»».....»».....»_.......... »......... ..._...... .......»..................... 1 or (f) hstrumented Flow Maawnment..........»._...»..»............. ............ ......... »........................ _....................... 2 (g) Preaeratlon... .»................. »....»...«.........»........_................».»..»..„.......»..............................................2 (h) Muent Flow EquaRtatbn.....».........» .».,,,,„»._.._.....»..:...».»..».............................................::.............2 (i) Grasse or OII Separators - Gravity.-.-- ._ __...� _...._......_ .. �.»._..._....«..._.»_..._. _..._...._..._...2 Mechanical....... «........»»..»...........».»..»..»......»...».».....»....._.......»»........ ....»..._ ...................3 Dissolved Ala Rotation.«.......»«...._»......_.......»._.._...._........--------- »........_............................... ........... a PF&AARYTREATMENTLINITSIPROCES$ES .» (a) 6"Ilc Tank (nee defWtion No. 43).... .....».._ .... ............_ _».......:» .........._............ (b) Imhoff Tank ..... _»:_.,:.»....»...,................»...._.........»..:.:.......... 5 (c) Primary Clarifiers. ....................»............»: »..»»..........».» .»..:..............:.................. ....... ............ .......... (d) Sewing Ponds or Senting Tanks for horganic Non to:k Materlafs (sludge handling faclitfes for water purMkation plants, sand. Gravel, stom and other misting operations except recreational aetivbles such as gem orgold mining)._......._..........».......:..._»........».........»»...._.»....»...».:..............«.............»..........2 SEMY DARtITREATIr WT U ffSMRDCESSES (a) Carbonecsous Stage (1) Aeratlon-Hgh Purity Oxygen System.«....»_.....»..».. «.»«..»._.«... ._.._..20 Dftaed Ala System. _.».».»..... _.»..........»...........10 Mechanical Air System (fbred, floating or rotor).:.. . �.r.._...-.»- _...-•- - ..d SeparateSludge Rf+sersdbn.»..».»»»._..»».».».«».»...»............_...».._» »...«.»..»..:»...3 (11) Tdck*p Filter HighRate ........ .....__.......»«.»»...»............... .«»..._.....«.«».»» _...»...».7 StandardRaU.....«.............._.««_..........._........_..«-•-••-•.-»--•------•----._».»...5 PackedTower.: ».». .»........»».».»..»»...............5 pa) Biological Aerated Filter or Aerated Biological Filter __ . _...__._. _..�.� .._«_.__. _.10 (M} Aerated Lagoons..........»...:.»»...»......_..........»«»».»»» ...._.....».».....» »».......«...:10 (v) Aotating Biological (vi) Sand Filters -htermittent bbioglcal.... _.». .•..••--•••-•---•-•� ..-».»2 Recirculatingbiological..._ ....................... ......... ...-»... ».3 Oil) Stabilization Lagoor>s._». _............ ......_............:.....»........._.__»...».........«..»»5 (is) Shgis stage system for combined carbonacsous.ramoval at SOD and nitrogenous removal by ttitrflkation (sire definition No. 12XPoinis for this item have tope In addition to items (6)(a)(1) through (6)(a)(vlll), uttilzing the exterded aeration process (sea definition No3a) ...__». ».».».»_•.2 1Mlzkq other than the extended aeration process... .«»».-»_—»_--•—_-- _..5 (x) Nutrient additions to enhance 000 nmaval.._...»».......:»...»»....�..._...�...._........».. (x1) Biological Culture ('Super Bugs')add4bn._»..._._.......««....».»....»».»—.»»•.»»—»•—«5 ^out Stage ion - High (b I (l ? Oxygen ssyste^! 20 Mused Air Sysum..»...».»....»......».......»«.».......»....».......»......«....»».»».....»».».»«10 Mechanical Air System (1bmd, floating or rMor)_...r.—.» -» ..»....»_....! Separate Sludge Reseratlon.«.�.».....»..».».».»»«.._^�.».»_......»..»»..» .»».».».....»..3 (fl) Trieklbg Finer-high"Rate.. •-•• ».».»» ...7 Standard Rate......._.. ................--»•--•-»»»•—•--••—»»»..---- ""'_•..5 PackedTowrer.»._...._....._.._._..r.._.......».»..._..»_.....«.....»»._..._.»»». r.«»»._.t 0 on) Biological Aerated Filter or Aerated Biological Filter._ «.--.--• (b) Rotating Biologicaf.Cortactors...«....».»..,.».»..»«....».«»..».»»«.....»».»..»_.»».._» .».10 (v) Sand Filter - Intermittent blobgkal.»......».........._«......_..»....._....._...... �MY......�-5 Recirculating biological • » ~M •--»»•»•- IERR WORMNANCEDTREATMEWDES (a) Activated Carbon Beds - without carbon ragenendlon....»»._.........«.....� _.....».........._.S wwith carbon mgeneratbn. (b) Po red or Granular.Activated Carbon Feed- �» without carbon regeneration—_...._ .......—..----.—.......—_ »_ A with carbon rogeneration«.»._.»......»_.«:.»».»»...........».».»........ .«......_.».»..._.» Foam Separation.«...«...».._......_.»--»-»•...•••---••-----»-« ionExchange..........._....._.»......._...:._...._......»_..»...._..........._......r._..._ .a Land Application of Treated Effluent (see definklon No. 22b) (rot applicable for rand, Cravat, stone and other slmliar rninhC operations) by high rate kdlnftn._ ._r_... Mkroscreans.................... �.».«_«......».... _..........«».».«.».....»._.»....».......»»_..........:....................5 Phosphorous Removal by Biological Processes (See definklon No. 26)...... _......„.�......»».�»».»..-»•_..._20 Polishing Ponds - without aeratlon..»..»»._»«»...............«.....•-•—•.•••._._.•»«•.»•»»••-•.-••-•-•-•.»•»••� with aeration...._.._....._.._.......................�.........._.r........»....».........._.».._..» • ., . - :(1) Post Aeration cascade. ................................................................... diffused or met hanical.................................... ............................ (m) ........ Reverse Osmosis ...................................... _............................ »................:.................................................5 (n) Sand or W:ed-Media Filters low rate ..... _«._...._..._...._....«...«...._..._.......... _.. 2 �NOh (a) rata...........»............»._................»...«........».» ..5 Treatment processes for rsrtnoirai of rneW or cyanide .................... «....«» ...» .........15 (p) treatment processes for removal of toxic materials other than metal or cyanide........«_.. ................... 15 (7) 811 ETREATMENT (a) Sludge Digestion Tank - Heated (anaerobkc).._..._.._..__.._..._......_............... _.................. 10 Aerobic.....«..:....».»_........«. .... ...»....«..................».«.............. ....... «..........................................5 Unheated(anaerobk)......................... »..«................................... ........................... «. ..... ................... 3 (b) Skkdg@ Stabilization (chemical orthermal) .... .................. ........................ ...«............».....«._..................5 (c) Sludge Drying Beds • Gravkty....».._....._._....».....:....._.«........».«._«.«»._.._.»_«...»..««.«.»... »............2 VacuumAssisted .... «......... »......... ... «.«..«.....«....«....................................... ... ..... ................................ (d) Sludge Elutriation.................. «»........... «...... «.......... »..«....................... ,.......».».«.................................... (e) Sludge Conditioner (chemical or thermal) ......... . .._..................5 (f) Sludge Thickener (gravity)....................:......_................................ «.................. ...... .»......._... _................. 5 (0) Dissolved Air Flotation Unit Inorappecabfe to a unit rated as(3)(1)).................... »».»... ......................... a (h) Sludge Gas Utfezation (including gas storage) ............................. ......__......_...««»......_............ _........ 2 (1) Sludge 'Holding Tank - Aerated ........... ..................... ».... .._.«.....«..................... _... « ......... «_«..................5 Nor►aerated........................... :........_...................:................................... .............................................. 2 (r) Sludge Irncl aerator (not Including activated carbon regeneration) ............. .............. ..........................1 0 . .... ..... . (k) Vacuum Fisher, Centrifuge. or Filter Prose or other similar dowatering dwices.._»...._»__._____ « «. «__«».10 (a) RESIDUALS UTiLQATIOWDISPOSAL (Inducing incinerated ash) (a) Lagoons.................................................................................«..............................................................2 (b) Land Application (surface and subsurface) (see definition 22a) by contracting to a land application operator or landfill operator who holds the land application permit orlandfill pemit......... »..........................................................»..........................................«..................... 2 (c Dedicated Landfel(budal) by the ps;;6 out d» wastewater treatment ............ (0) (a) Chlorination.........««...._»..«...............«..........««._»..»...».«...»»..«...««....«..«...«....«.«......«......... (b) Dechlorination.....»....«.»..».......«.._....».........«....»...««...».»..«...«........«.....«.» (c) .............«.».:............ Ozae...«..............«........«..»««...........»........«.....«.«.«.......».»«...........»..........»...«.................5 (d) Radiation ..... ......... .......................... «.«..........».....»«......................««.........«..»...............................«5 (to). CHEMICAL ADDITION SYSTEM(S) ( see definblon No. a) [not applicable to chemical additions rated as Rem (3)0). (�ia)(xi), (6Ka). (6)(b)� (7)(b). (7)(0). (ea). (o)(b) or (o)(c) 6 points each: ...«............««..«.»...«...».._....«....»............».... ..........».»....« ............._.». ..S ..««............. «......... «.............. ««.............. .....«_»«»««............... «.......... .......... _... ..._«» ..«..»».....»_«..«....«_»----------- «--- .-------- .--------- .»......__... .................... 5 (11) 1kaSCBl/JJEOLRS U1T51PFlOCESSES.....«....««.«««««»«..»...«..«..»«.«......«..».....««..««.«»«....««« ....»«....«. ....5 (a) Holding Ponds, Holding Tanks or Settling Ponds for Organic or Toxic Materials Including wastes from mining operations containing nitrogen or phosphorus compounds In amounts significantly'greater than Is common for domestic wastewater ................................................««.........«.«..................«....«.....................A (b) Effluent Flow Equalization (rot applicable to storage basins which are Inhekent In land application systems) --- 2 (a) (d) Stage Discharge (rot applicable to storage basins inherent In land application systsms� Pumps.......«.«.«..««.....«.».«....___«.»._...«.:«....._.......«_—....«:«_................:»...«.........«._«.«« (e) Stand -By Power Supply ............ ««.«.».«.«.»..».««.««.».«..««..«.««._...«..»�«.«.«.».»«.«.«.:...«.«..��.» (t) Thermal Pollution Control Device...«................».........«««.....«».........._«........«.«».:..»... »«....«.....»«»..3 TOTAL POUTTat....«....«»..»...««..«........._......�.....«...».».«..,,f C ASSFKATION ClsI_«.«.«...».....:.«».««..............«...«......._............«_ .«......��«...«625 Points Class II.._ ««.»»........................ .........«.««.««« 26.50 Points CRtsall....»....»«..».»�.«.....«.«...«.«..««».».»».«..««.«.......«.«.«....«.««�51.85 Points Facilities haft a ratktg done though four points, nclusivs, do not require a ttsrtllad operator. Facilkles having an activated sludge process we be assived a minimum dnsMlatlon of Class IL Fsanes hrAV tnatmarM processes for the removal of metal or cyanide will be assignted a ftii .m. claWlation'd Class IL Fadkin having treatment processes for the biological removal of phosphorus mil be assigned a n* naum classification of Cie"'Ill. — — — — — — AOD4 DEFWI TIONS The following definition shall apply throughout this S er. (1) Activated Carbon Bads. A phya(csVchemial method forr ducky soluble organic material from wastewater o luenr The column -type beds used in this method WIN have a flow rate varying from two to eight gallon per minute per square foot and may be either upflow or downfiow carbon beds. Carbon may or My not be regenerated on the wastewater trealmort plarM she; (2) Aerated Lagoorts. A basin In which all solkls are maintains l In Suspension and by which bktoglal oxidation or organic matter Is reduced through artificially accelerated traMrar of oxygen on a flow -through bask; (3) Aeration. A proosss of bnkvplrng about Intimate contact between air or high purity Oxygen In a liquid by spraying; agitation or d flusbng3a) Extended Aeration. An activated sludge process utilizing a minimum hydraulic detention tkne of to hours. (4) Agriculturally managed site. Any she on which a crop Is produced. managed. and harvested (Crop Includes Fame. grain, miles, stir.); (5) Air Stro tg. A process by which the ammonium Ion Isfirst convened to dissolved ammonla (pH adjustment) with the ammonia then released to the armosphers by physical mu; or other similar processes which remove petroleum products such as bereene, toluene, and Xylem; (0) Carbon Regenerettim The regeeration of exhausted carbon by the use of a furnace to provide extremely high temperatures which volafte.and oxidize the absorbed Impurwes; m Caxbonamous Stage. A stage of wastewater treatment designed to achieve 'tserondW oftwe omits: (8) Cer"ugs. A mechanical device In which cerrb ugal fort:•. Is used to separate soilds from liquids or to separate liquids of dlforwi denh..as; t. �lhey�e«,aa � Minty taddition p�witdHi)to rsrrd wastewater rand�differreentt application poet tier purposes of Improvingeve a specific coeds removal. r axsred one system: the capability to add chemical(s) to dual units wll be rated as oil system; to add aims tm� at a different application do p considered one purposes wll result n the systems being rated as separate systems; blkY application points for different (10) Chemical Sludge Comftning. The addition of a chemical compound such a 1me, iodic .,or a p*=r to wet Mudge to coalesce the rheas prior to fts appeatbn to a dteftng ewadevice; (11) Cbeed Cyels Systems. Use of holding ponds or holding tanks for cortaInrtsrd of wastewater coma" inorganic, non -toxic materials from sand, gravel. crushed atom or other similar orperatlorks. Such systems shag carry a maximum of two poles regardbu of pumping fae tin or any other appurtenances; (12) Combined Removal of Caftramous BOO and Nitrogenous Removal by MAIcatbn• A single stage system required to achieve permit effluent Ws on BOD and ammonia Mrogen within the same biological reactor, (13) DectiorinatbR The partial or complete reduction of residual chlorine In a liquid by any chemical or phty;lal process; (14) Denhtralation Process. The conversion of rtltrate-nUmp ri to naogen gas; r- State of North Carolina Department of Environment, Health and Natural Resources 1 • • Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary p� CC A. Preston Howard, Jr., P.E., Director �� ®C H N July 7, 1995 9 NA ;,TRIL RE-SO.11,C2,0 Ms. Jane W. Hope 3811 Bonwood Drive Charlotte, North Carolina 28211 �iV`tvi�7i� :its G''�y.'Pf'f�112� t �'. S Pi g d . ,,r�q 2 F Subject: Application No. NCG550768 Hope Residence Wastewater Treatment Plant Iredell County Dear Ms. Hope: The Division's Permits and Engineering Unit acknowledges receipt of your permit application and supporting materials received on June 19, 1995. I am conducting a detailed engineering review of this application which has been assigned the number shown above. Please refer to this number when making inquiries on this project. Be aware that the Division's regional office, copied below, Must provide recommendations from the Regional Supervisor for this project prior to final action by the Division. I am, by copy of this letter, requesting that our Regional Office Supervisor prepare a staff report and recommendations regarding this discharge. If you have any questions regarding this application, please contact me at 919/733-5083 ext. 502. Sincerely, Jay B.. Lucas; P.E. Environmental Engineer, ce: .Mooresville Regional Office -'Water Quality-1, - Permit File P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper A NORTH CAROLINA DEPARTMENT OF NATURAL RESOURCES AND COMMUNITY DEVELOPMENT ENVIRONMENTAL MANAGEMENT COMMISSION NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM APPLICATION FOR PERMIT TO DISCHARGE - SHORT FORM D-SFR FOR AGENCY USE APPLICATION NUMBER DATE RECEIVED YEAR MONTH DAY TO BE FILED BY SINGLE FAMILY RESIDENCES ONLY. FEES: NEW APPLICATION....... 240 PERMIT MODIFICATION ....... $240 PERMIT RENEWAL ........$240 PERMIT NAME CHANGE ....... $100 1. Mailing address of applicant: A. Name Jane W. Hope & Harold P. Hope. Jr. B. Street Address 3811 Bonwood Drive - C. City Charlotte. N.C. D. County Mecklenburg County E. ZIP Code 28211 F. Telephone No. (Home) 704 364-1828 (Work) Same AREA AREA CODE CODE 2. Location of residence producing ' discharger C� A. Street Address and State Road # 123 Langdon Road A(1) Parcel/Lot # Section 8—Lot 396 Deed Book #/Page# 692 / 788 B. City _Mooresville. N.C. o C. County Iredell County " r D. ZIP Code 28115 Tax Map 2L-2j Parcel 396 n 3. This NPDES Permit application applies to which of the following (check appropriate space): A. New or Proposed x This is a -proposed new discharge B. Existing Unpermitted to serve an existing single family residence C. Existing Renewal currently being served by a failing D. Modification septic tank system. E. Renewal w/ Modification Description' of Modification 4.. Number of bedrooms at residence: - 3 Number of Homes on System: 1 5. Type of system being used to treat wastewater (check appropriate space): A. Septic Tank and Sand Filter _ B. Septic Tank, Dual or Recirculating Sandfilters, Cascade Reaeration X C. I Conventional Septic Tank, D. Other (describe treatment) 6. Does your treatment system have chlorination? Yes X No Proposed (continued on back) Short Form D-SFR Revised 7/93 7. Name of receiving water or waters which will accept the discharge Unnamed cove of Lake _N6rman on the Catawba River 8. Is any activity being performed at the residence which would generate wastes other than domestic wastes, such as photographic processing? Yes No _ If yes, please explain: I certify that I am familiar with. the information contained in the application and that to the best of my knowledge and belief such information is true, complete and accurate. Harold P. Hopei Jr. Jane W. Hope Printed Name of Person ,Signing Title (homeowner, etc.) March 30i 1995 Date Application Signed 0 1 w s? S!gAAure .of Applicant Mail three copies of the completed application, a map or drawing showing the location of the discharge, along with the appropriate processing fee to: DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION - PERMITS & ENGINEERING UNIT ATTENTION: NPDES GROUP POST OFFICE BOX 29535 RALEIGH, NORTH CAROLINA 27626-0636 . North Carolina General Statute 143-215.6(B) provides that: Any person who knowingly makes any false_ statement, representation, or certification in any application, record, report; plan, or other document filed or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 2.1 or regulations of the Environmental Management, Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed . $10,000, or by imprisonment not to exceed six months, or by both, (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $10,0.00 or imprisonment not more than 5 . years, or both, for a similar offense). sHOFfTFORM DSFR Short Form D-SFR Revised 7/93 ,` • � -.��,�� �� pooh State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management 512 North Salisbury Street • Raleigh, North Carolina 27611 James B. Hunt, Jr., Governor A. Preston Howard, Jr., P.E. Jonathan B. Howes, Secretary Director NOTICE OF INTENT National Pollutant Discharge Elimination System Application for Coverage under General Permit NCG550000; Single Family Domestic Units 1. Name, Address , location, and telephone number of facility requesting Permit. A. Official Name: Jane W. Hone & Harold P. Hopeq J_" Owner B. Mailing Address: (1)Street Address; 3811 Bonwood Drive (2)City; Charlotte— , (3)State; North Carolinar— (4)Zip; 28211 --' 5 r_. r• (5)County; Mekl enburg County C. Location: (Attach map delineating general facility location) (1)Street Address; 123 Lanadon Road z� (2)City; Mooresville (3)State; - North Carolina _ (4)County; Iredell County D. Telephone Number; (704 364- 1828 - - 2. Facility Contact: A. Name; Jane W. Hope B. Title; Owner C. Company Name; Jane W. H6pe D. Phone Number; ( 704 ) '364 - 1828 3. 'Application type (check appropriate selection): A. New or Proposed; X �1 B. Existing; If previously permitted, provide permit number --� and issue date C. Modification; (Describe the nature of the modification): This is a proposed new discharge to serve an existing 3-bedroom single family residence currently being served by a failing septic tank system. 4. Description of discharge. A. Please state the number of separate discharge points. B. Please describe the amount of wastewater being discharged per each separate'gdik ar- (Design flow is based on 120 GPD/bedroom with a minimum of 240 GPD/ home}' 1:360 gallons per day (gpd), 2: (gpd) 3: (gpd) 4: (gpd) Page 1 v I R C. Check the duration and frequency of the discharge, per each separate discharge point 1.Continuous: X 2.Intermittent (please describe): 3.Seasonal: (check the month(s) the discharge occurs):January [ ];February [ ];March [ ]; April [ ], May [ ]; June [ ]; July [ ];,August [ ]; September [ ]; October [ ]; November [ ]; December [ I. 4.How many days per week is there a discharge?(check the days the discharge occurs) Monday [)d, Tuesday W, Wednesday.[ , Thursday k],Friday [d, Saturday bd, Sunday bd. 5.How much of the volume discharged is treated? (State in percent) 100 % D. Describe the type of wastewater being discharged. (please list any known toxants being discharged from this residence); regular clomestic sewage from this residence — no known toxants E. Check the appropriate type of treatment being used to treat the wastewater, 1. Septic Tank; 2. Sand Filter(s); 3. Recirculating Sand Filter(s), 4. Chlorination; 5. Other form of disinfection(specify); 6. Aeration(specify type); 7. Other(describe, be specific); X 1j500 gallon capacity1 precast con. X 12.5' wide x 25.0' long X 100 gallon capacity X Cascade reaeration — 9 step B. Please describe in detail the information checked above. (Include specifics for each check; to include: type, dimensions, treatment amounts, design volumes, retention times for each system, manufacture's specifics and contractor's specifics) Existing treatment facilities should be described in detail and design criteria or operational data should be provided (including calculations) to ensure that the facility can comply with requirements of rm the General Peit.The following are the minimum design requirements needed for each of the treatments listed above: a. Septic Tank; Minimum tank septic tank size shall be 750 gallons for two bedrooms and 900 gallons for three bedrooms. The Division recommends the use of a 900 gallon tank for a two bedroom and a 1200 gallon tank for a three bedroom unit. If excavation into bedrock is necessary for the septic tank or sand filter then a liner of at least 10 mm thickness shall be provided for the septic tank and/or sand filter. b. Sand Filters; These shall be used to provide secondary treatment. Dual or recirculating filters are required for new systems. For dual sand filters, the loading rate shall be no greater than 1.15 GPD per square foot for primary filters and no greater than 2.3 GPD per square foot for secondary filters. Recirculating Sand Filters should be able to handle 5.0. GPD per square foot with no more than a 3:1 recirculating. ratio. Sand shall conform to the Division's. standards of 0.35 to 0.5 mm effective size, 3.0 uniformity coefficient, and 0.5% dust content. c. Chlorination; The chlorine contact chamber shall have at least a 30 minute detention time. The volume should be calculated as follows: Volume (gallons)= (design flow x 0.5)/ 24 hours. Discharge pipe from the chlorinator shall be perforated. d.Cascade aeration should consist of a 5 step concrete trough but may also be made of rip rap. NOTE: Construction of any wastewater treatment facilities require submission of three (3) sets of plans and specifications along with their application. Design of treatment facilities must comply with requirement 15A NCAC 2H .0138. If construction is necessary to meet permit - requirements, include the three sets of plans and specifications with the application. Name of receiving water: Lake Norman Classification: (Attach a USGS topographical map with all discharge point(s) clearly marked) Page 2 6. Is the discharge directly to the receiving water?(Y,N) Yes _ If no, state specifically the discharge point. Mark clearly the pathway to the potential receiving waters on the site map. (This includes tracing the pathway of the storm sewer to its discharge point, if a storm sewer is the. only viable means of discharge.) I i 7. Please address possible non -discharge alternatives for the following options: A. Connection to a Regional Sewer Collection System; none available at this location B. Subsurface Disposal; soils are not suitable for another repair C. Spray Irrigation; no available area for spray irrigation 8. I certify that I am familiar with the information containzd in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing Title Date Application Signed Signature of Applicant Harold P. Hopeq Jr. ."lane W_ Ein= e NORTH CAROLINA GENERAL STATUTE 143-215.6 (B) (2) PROVIDES THAT: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $10,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $10,000 or imprisonment not more than 5 years, or both, for a similar offense.) Notice of Intent must be accompanied by a check or money order for $240.00 made payable to the North Carolina Department of Environment, Health, and Natural Resources. Mail three (3) copies of entire package to: Division of Environmental Management NPDES Permits Group Post Office Box 29535 Raleigh, North Carolina 27626-0535 Page 3 ENGINEER REPORT EVALUATION OF OPTIONS FOR WASTEWATER DISPOSAL.SYSTEM IMPROVEMENTS SERVING EXISTING 3—BEDROOM RESIDENCE LOCATED AT 123 LANGDON ROAD SECTION *8, LOT *396 DAVIDSON TOWNSHIP, IREDELL COUNTY, NORTH CAROLINA PROPERTY MAILING ADDRESS: 123 LANGDON ROAD, MOORESVILLE, N.C. 28115 JANE W. HOPE & HAROLD P. HOPE, JR. -- OWNERS 3811 BONWOOD DRIVE CHARLOTTE, N.C. 28211 PREPARED BY: DAVID A. ROBERTS,. P.E. 309 NORTH ZION STREET LANDIS, NORTH CAROLINA 28088 (704) 857-3800 JUN 51995 i�fir,,,, , SEAL ' • 6271 'v a DEFT'. QF RNmRONAIENT HEALTF�, NATU AL RESOUTZCES JUL 1� 1995 DIVISION Of ENVIF00,1E1ITA1 �;h;lAgEF;9ENP mookS,V1l4E ;ftG>;IO.nt OFFICE EVALUATION OF OPTIONS FOR WASTEWATER DISPOSAL SYSTEM IMPROVEMENTS SERVING 123 LANGDON ROAD DAVIDSON TOWNSHIP, IREDELL COUNTY, NORTH CAROLINA EXISTING CONDITIONS: #123 Langdon Road is located along the southeastern margin of Langdon Road near its cul-de-sac, just off State Road #1457, off McKendree Church Road (S.R. #1115), adjoining the waters of Lake Norman on the Catawba River, along the shoreline of an unnamed cove of Lake Norman, at a distance of approximately 3 miles west of Brawley Elementary School, west of the Town of Mooresville, in Davidson Township of Iredell County. #123 Langdon Road is 2/3 acre in size, and consists of gently rolling terrain along the waterfront portion of the lot, with steep topography along the front portion of the house near Langdon Road. The existing 3-bedroom single family residence on this lot was constructed approximately twenty years ag.o,'and a permit was issued at that time by the Iredell County Health Department for a septic tank system of on -site wastewater disposal. Over the years, the original septic tank system of wastewater diposal failed, due to unsuitable soil on this site. Several repairs to the system have been made, including the pumping to disposal trenches upslope of the ' concrete driveway. At present, the wastewater disposal trenches are not performing properly, and need to be abandoned, and a solution is needed for making improvements to the existing wastewater diposal system. THE_ OPTIONS FOR_ WASTEWATER_ D_ISP_OSA_L SYSTEM IMPROVEMENTS ARE AS FOLLOWS: ------------------ --- --------- (1) Installing on -site ground absorption wastewater disposal system improvements on this site; (2) Acquiring adjoining property and installing on -site subsurface disposal system on the acquired site; (3) Acquire adjoining property and install spray irrigation/land application system of wastewater disposal; (4) Acquire adjoining property and install drip emitter system of land application wastewater disposal; (5) Install pump station and force main to nearest community sewerage system; and (6) On -site treatment system with final disposal of effluent by discharge into Lake Norman. Each of these methods of wastewater disposal will be evaluated herein.. ENGINEERING REPORT PAGE 1 OF 4 OPTION #1: INSTALLING ON -SITE GROUND ABSORPTION WASTEWATER ------ ------------------- ------ ---------- ---------- DISPOSAL SYSTEM IMPROVEMENTS ON THIS SITE. -------- ------------------ -- ---- ----- During recent telephone conversations with Mr. David Hinson of the Iredell County Health Department concerning this site, he informed me that their recent evaluation of the soil and site conditions at this location revealed this entire site to be unsuitable for use with ground -absorption wastewater -disposal systems, due to poor soil permeability, due to the steep topography across most of this lot, and due to the location of existing structures and existing wells on this lot. Based upon my telephone conversation with Mr. Hinson, this option is not available to the existing owner at this location. OPTION #2: ACQUIRE ADJOINING PROPERTY AND INSTALL ON -SITE ------ -- —-------- ----------------- SUB -SURFACE DISPOSAL SYSTEM TO SERVE LOT #123 LANGDON ROAD. A look at the sub -division map and tax maps for this location reveals that all existing waterfront lots in reasonable proximity to this site are built -upon, except property within the interior loop of State Road #1457, which is owned by Crescent Land and.Timber Company. Although this location may be useable for ground absorption wastewater disposal, Crescent Land and Timber Company will not make this land available to the Owners. Because of the apparent unavailability of this property to the Owner, this option for wastewater disposal is not available to the Owner at this time. OPTION #3: ACQUIRE ADJOINING PROPERTY -.AND INSTALL SPRAY ------ --- ------------------- ---------- ----- IRRIGATIONLLAND APPLICATION WASTEWATER SYSTEM_ Because of the unavailability of existing properties in general proximity to the Owner's site, as described in OPTION #2 above, the Owner does not have the option of utilizing the spray irrigation/land application method of wastewater disposal near his existing property. For these reasons, the Engineer feels that this option is not available to the Owner at this time. OPTION #4: AC UIRE ADJOINING PROPERTY AND INSTALL DRIP IRRIGATION LAND APPLICATION WASTEWATER SYSTEM. Because of the unavailability of existing properties in general proximity to the Owner's site, as described in OPTION #2 and #3 above, the Owner does not have the option -of utilizing the drip irrigation/land application method of wastewater disposal near this existing property. For these reasons, the Engineer feels that this option'is not available to the Owner at this time. ENGINEERING REPORT PAGE 2 OF 4 OPTION #5: INSTALL PUMP STATION AND FORCE MAIN PIPING SYSTEM_ ------------ ----------- --- ----- ---- ------ FROM THIS SITE TO THE LOCATION- OF THE NEAREST — ---- ---- ---- -- ------------ --- ------ COMMUNITY SEWERAGE SYSTEM. The nearest community sewerage system to this site is located in Mallard Head Subdivision located south of Brawley School Road (S.R.#1100) at a distance of approximately 2 miles southeast of #123 Langdon Road, when measured along a straight line. To.extend a force main from 123 Langdon Road to the location of the Mallard Head Subdivision by following the road right-of-way southwestward along Langdon Road and State Road #1457, along McKendree Church Road(S.R. #1115), along Brawley School Road (S.R.#1100), a distance of approximately 3.0 miles to the entrance into Mallard Head Subdivision. The cost associated with extending the force main along the road right-of-way for a distance of 3.0 miles.'is estimated at $150,000 to $230,000, plus the cost of acquiring any easements that may be necessary along this route. This estimate is based upon the assumption that the Owner would be allowed to connect with the existing sewerage system at Mallard Head Subdivision. Because of.the high costs associated with the extension of force main piping from this site to the nearest sewerage system, it is the opinion of the Engineer that this option is 'T neither practical nor economically feasible for solving the existing wastewater disposal problem at 123 Langdon Road. OPTION #6 ON -SITE WASTEWATER TREATMENT SYSTEM WITH FINAL ------ ---------------------------- ------ ---- ----- DISPOSAL BY DISCHARGE INTO LAKE NORMAN. -------- ----------- ---- ---- ------- Although this option in not a preferred choice for the Owner, the Engineer, and representatives of the Division of Environmental Management, it may be the most practical option for dealing with the problem of disposing of the existing wastewater from the existing residence at 123 Langdon Road. The Engineer proposes installing a new wastewater treatment system at this existing residence, consisting of a new 1,500 gallon capacity precast concrete septic tank with baffle, a new 1,500 gallon capacity precast concrete dosing tank with 1/2 horsepower submersible effluent pump and liquid level control float switch, pumping to a recirculating sand filter bed of 12.5' by 25.0' size with flow dividers at the underdrain return line for splitting flow from the sand filter .for 3/4 flow returning to the dosing tank for mixing with effluent from the septic tank and with 1/4 flow draining to a new 100 gallon capacity precast concrete chlorination tank with tablet chlorinator at the inlet pipe, with step aeration from its outlet, with 4" diameter Schedule 40 PVC gravity piping to the proposed discharge point at the bottom of Lake Norman at a distance of 200 feet from shoreline off the Owner's property, using 8" ENGINEERING REPORT PAGE 3 OF 4 masonry block around the pipe to secure it to the bottom of the lake. An alarm panel shall be installed within the existing residence and connected with a liquid level float switch located within the dosing tank so as to notify the Owner of any high water conditions that may occur within the dosing tank. The recirculating sand filter bed will be constructed below existing grade using a polyethylene liner, 4" diameter porous plastic tubing underdrain piping system in 6" stone base layer, with 30" thick layer of approved filtering sand, with 1 1/4" PVC distribution piping system at the top of the sand filter bed covered with 6" layer of washed stone. The top of the sand filter shall be set flush with existing grade and the yard surface near the sand filter shall be shaped to divert stormwater away from the sand filter. Piping from.the underdrains of the sand filter bed to the flow dividers in concrete box, with lid, shall be 4" diameter Schedule 40 PVC laid at 1.0 percent minimum slope, and shall be securely sealed at its passage through the liner membrane so as to be watertight. The new wastewater treatment and disposal system shall be placed a minimum of 15' from the existing residence, 10' minimum from the side lot property line, 50' minimum from existing wells, and 50' minimum from the full pond elevation of Lake Norman. The Engineer estimates construction costs associated with this system of wastewater treatment and disposal to be between $9,000 to $16,000. The Engineer requests that the North Carolina Division of Environmental Management grant a permit to the Owner, Jane W. Hope and Harold P. Hope, Jr., for the construction, operation and maintenance of this proposed wastewater treatment system, with final disposal by discharge into an unnamed cove of Lake Norman. END OF ENGINEERING REPORT ENGINEERING REPORT PAGE 4 OF 4 �•'• �, , ( 1 �).,;" �, S�� 1 �`r�o°0 J ,`��%�� >�� 1, �1� � • it 009 d'2K _ aT uP:rPPn(y gwroN uPm-ION ayye� o+�o �s ; (1 'L(`_� i' 1 - ' � 1 `i. a' i � ��� �`•; ) :/ i'/' �B i , / \ �_ J \J \\ ��� ��-Cpr`��/+3= ���J ,�kkG.it��itti�j' t '• � it N :.i a / • I' ` - / ' tom^ 1 ail J �• /// �. �, ( ' , `BL dwea jeos it nnaq°� = LSe (' �� _•' p l,� ,� ,:. / /' /, � � '� , �; II l I ` lJ o • %'f I _ ' 1�,' _ ,.\ _;;�.li .� is _'•�� If Uji Al i �00� / 1. ,, , •,:_ . ; ea - , / '2 x ate. /- 009 ti 101, It / l Es gre -9 - (-I _rl �,,i� --r, -`U7:;--- -•_��l\\ �) \` -`°� 1"� \1� 1 .r tee,, 5 �' rr .� � �i•o �` y �/ \ . r,, - " _ 1:1 �;1 •\.' to � 1 V. 74 1 4 go0 goo \) i //. _`cam \�� I li •11 � _ , 790 .o Creek o // ego .. •.,�) •.�`'c .� ��- � `. 1, 6well 0 1i N t'N I% 10 lk, ` \ +\\ - lip 'll' ((� ,4 \ c -i'1N ,�, \ � �•,' \B�stwall80 �', \ f r � 11�' l �'•III • (i ( / / : i .\ �_-' \ .,�i r I � r/, , �„ • , ` I` I I as: •.Mayhew BEM Boat`. ( t o Ramp ie , i l� l/� eoo _ V. Lake Norman adrangle Map North Qu Iredel l CountyA N. C\.. Viz,Boo OP � 2L-A-II o, r/ 391 '334 rn )o 393 (1594) �� w 392 395 N(ilDO 1 396 �1 ►y` -.� 397 398 �T3 tDcp a3 - 363 399 %3 ►2) 3` 43 400 3 g0�'( o�i 130 BOG 3R� 401 's o� t�3\ _.LRE._Q. LL--Cou. rt , 1=: V 14SON ToWN 5-A%4? _ .1pv( mAp # ZL-2 Q N 1pn 404 1.1 40.1 tD ►- .r-3i 406 402 162 407 N � 22s 403C 431 ;u 1 110 \ - --- 372 A 334 ►•1oR�ca - 'ems . N 39/ 90 393 7� y ti 3 r \ab (I 594) �0O w r 392 395 Y 2L-A-II a�yA. ,51 �397 � 3 ' 398 �1 g�y�G��g 5� Zg6 w `53 NQ 514 �6 (1593) Lij N k� 363 s� �s 399 513 e� (1592) ` 400 404 3 *00 43 130 148 1 * 1 _ 40$� 365C v 401 so 406 WASTEWATER DISPOSAL U" OPTION #24 #3a and #4 es4 � I RE. (Zia LL Cou NTI,1% V 1 QZON To&3N SfitQ .- TAyc mop # ZL-2 V O In 172 402 '* - 16Z 407 a � i \ 403C Q —cm � y `I/ - awe \� _ a�•1• •' Q \ . �,. � 1_ �? %moo` � -- �0 aoo • �',.� %1;. " ,��� `,�. \ �i II Lam' � •Bh}$'S'$�- `,\ 7611 818 Bostwalts` s�z ((( Propo ed Force Main e `\ Option #5 / per. DO - 'j// Il l��'Ch'� \.\ _ _ /) \- ` �\ I I ll �', °U\ ^\^ J�. 1 - •82G - .. Mayhew) �, - �� \, cz ": - Mallard Head 1 t I \ 80 8!M 860 if Creek J 33C = orrows .7 - 1! \, I "775 II\ v - ..(r _�r \ �-�' \\l\�J ram' ... _ \ , •� � � \ 40 r l•, - /--- - ',�- - ' ! 825 i \t/ �787 WASTEWATER DISPOSAL OPTION #5/ %%�, 1 • ' _� LAKE NORMAN QUADRANGLE MAP . I ��' •In. �� 0 1�J_ IREDELL COUNTY HEALTH DEPARTMENT P.O. Box 1268 • Statesville, North Carolina 28687 • (704) 873-7291 William D. Mashburn, M.P.H. Health Director Jane Hope 3811 Bonwood Drive Charlotte, NC 28211 Dear Mrs. Hope:. May 23, 1994 RE: Section 8 Lot 396 David Hinson and I have completed an evaluation of the malfunctioning septic system, and the soils on the above referenced lot (maps 1). The original septic system has been replaced twice on -site. As we.can best determine, the effluent is being directed through fractured saprolite and bedrock to the opposite side of the peninsula where it is surfacing. The effluent is not being properly treated before it is surfacing, _ and then the surfaced effluent is flowing downhill into Lake Norman. The existing septic tank and pump tank are taking on surface water through the risers and possibly subsurface water through the sidewalls. Both sources of water intrusion contribute to hydraulic overload of the nitrification field and increase the volume of surfacing effluent. We have made four auger borings over the remainder of the lot which'is not occupied by the existing systems and setbacks (diagram 1). The soil profiles exhibit a number of characteristics which are not favorable for proper functioning of a septic system, and we therefore, cannot recommend any type of on -site repair. I can provide you with a photocopy of my field notes and a detailed.report. By permission of Mr. Jim Bass of Crescent Resources, we have made several auger borings over the interior of Digh Circle. We have located some soil which could be used for the installation of a nitrification field for the residence on lot 396. I have measured and flagged an area adequate to accommodate a conventional type .septic system and a conventional repait for up to a three bedroom residence (diagram 2). If you intend to remodel -the house in the future and increase the number of bedrooms, I recommend that the septic system be designed and installed presently for the proposed change. Based on a thorough evaluation of the existing septic system and of the soil on lot 396 and the interior land, I offer the U Jane Hope May 23, 1994 Page 2 following recommendation. You may, whether by means of purchase or a legal deed of easement, secure the designated area described in diagram 2 or some other area where we perform a formal site evaluation, for the purpose of installing a new nitrification field to replace the existing field; and secure, by purchase or deed of easement, a strip of land at least one foot wide which connects lot 396 and the interior land used for the nitrification field. Instructions about the size, location, and construction of the nitrification field would be specified on a repair permit issued by this department. Instructions about the repair or the replacement of the septic tank, the pump tank, the pump and alarm and appurtenances would be determined after assessing the exact condition of these components. Mr. Bass asked that I direct you to him for information about the interior land of Digh Circle. I encourage you to pursue this off -site repair and am at your disposal if I can be of any further assistance. Please keep me informed of the status of negotiations or decisions. AL/mb Enclosures: (4) Cordially, Andrea Lemon, R.S. Soil Specialist I #A►• LaT 39 G SEc.Tto-J 8 C akc,-N CtRCLE�) t>1^C -A,M APPf2c'!,1C I".Sc, ----- LA NGl Do N R o g c> -o © EXt5TIh1C1 lzEPA-IR IN THIS Ar-e7A �G tiC 'eF �RIJE`^IA� v4SLL HotiSE �d 1- ✓ti— ►-A K E N o Ct t,&A tJ ✓— ®='srrc of AvCiElt goR\w(3z 41.2 NA(L U+t LuuJar-7 16 i Sm THE CIRNErRS --ttZ 37 y ftRE Mfki2KEA �^►lT�j WHlrt Ali', WITH Brut FLA,,GING, 1N o RT i CRESCENT RESOURCES INC. P.O. Box 396 Terrell, NC 28682 (704)478-2130 July 18, 1994 Jane Hope 3811 Bonwood Drive Charlotte, NC 28211 Dear Mrs. Hope, I have processed the request to purchase Crescent property that you sent to me. After review with our Charlotte office, I regret to inform you that this property is not for sale at this time. Due to the vast number of requests that we get, I cannot maintain any waiting list for a specific property: I suggest you re -submit your request in 6 months if you are still interested in acquisition. If you have any questions, I can be reached by telephone at 704-478-2130. Sincerely, �Gf/1-ate James H. Bass, Jr. Division Forester JHB/dmr SPECIFICATIONS FOR RECIRCULATING SAND FILTER WASTEWATER TREATMENT SYSTEM WITH FINAL DISPOSAL BY DISCHARGE INTO UNNAMED COVE OF LAKE NORMAN IN THE CATAWBA RIVER BASIN SERVING EXISTING SINGLE FAMILY 3-BEDROOM RESIDENCE SECTION 8, LOT 396 123 LANGDON ROAD DAVIDSON TOWNSHIP, IREDELL COUNTY, NORTH CAROLINA -------------- ---------------------------------------------- JANE W. HOPE AND HAROLD P. HOPE, JR. 3811 BONWOOD DRIVE CHARLOTTE, N.C. 28211 (704) 364-1828 HOME ------------------------------------------------------------- GENERAL PERMIT NUMBER NCG550000 PREPARED BY: DAVID A. ROBERTS, P.E. .309 NORTH ZION STREET LANDIS, NORTH CAROLINA 28088 (704) 857-3800 JUN 151995 ,,���nnnrrrryr ���•�tH CARp��% oFEssip* % q . ?¢ SEAL 's _ 6271 9G M SITE PREPARATION REQUIREMENTS FOR CONSTRUCTION OF A SEPTIC TANK, DOSING TANK, RECIRCULATING SAND FILTER BED, CHLORINATOR, AND STEP AERATOR SYSTEM OF WASTEWATER TREATMENT WITH FINAL DISPOSAL BY DISCHARGE INTO UNNAMED COVE OF LAKE NORMAN IN THE CATAWBA RIVER BASIN JANE W. HOPE AND HAROLD P. HOPE, JR. - OWNERS NOTE: PRIOR TO BEGINNING ANY ACTUAL CONSTRUCTION OF THE WASTEWATER DISPOSAL SYSTEM, THE INSTALLATION CONTRACTOR SHALL NOTIFY THE ENGINEER OF HIS INTENDED CONSTRUCTION SCHEDULE AND SHALL ARRANGE A PRE -CONSTRUCTION CONFERENCE WITH THE ENGINEER AT THE SITE FOR. THE PURPOSE OF REVIEWING THE WORK TO BE DONE AND FOR ANSWERING ANY QUESTIONS THE INSTALLATION CONTRACTOR MAY HAVE ABOUT THE CONSTRUCTION OF THE WASTEWATER SYSTEM. NO CHANGES ARE TO BE MADE TO THE WASTEWATER DISPOSAL SYSTEM WITHOUT THE WRITTEN PERMISSION OF THE ENGINEER. (a) The Contractor shall conduct careful excavation at the site in order to locate existing wastewater piping from the existing residence to the existing septic tank. Once the Contractor has determined the location of the existing septic tank on the lot, and has traced all existing wastewater piping from the existing septic tank back to the residence to assure that all wastewater piping from the residence is contained within a single piping system, Contractor shall be ready to begin construction of the new wastewater treatment system. (b) Wastewater piping system from the existing residence to the location of the new septic tank shall be 4" diameter Schedule 40 PVC sewer pipe laid at 1.0% minimum grade. (c) The pretreatment tank shall consist of a 1,500 gallon capacity, reinforced precast concrete septic tank with full baffle, and shall have easy access to each chamber from ground levelfor checking and pumping. The first chamber of the pre-treatment tank shall contain 2/3 to 3/4 of the volume of the total tank and the baffle shall contain a horizontal opening across the tank at about midway its height. Locate the pre-treatment tank at such height as to provide approximately 8 inches of soil cover over the top of the tank. The tank shall be properly sealed using 1" diameter butyl rubber pliable sealant as approved by the tank manufacturer. (d) Wastewater piping system from the pre-treatment tank to the location of the dosing tank shall be 4" diameter Schedule 40 PVC sewer -pipe laid at 1.0% minimum grade. (e) The dosing tank shall consist of 1,500 gallon capacity, reinforced, precast concrete tank with baffle containing two 4" diameter openings located no more than 6" above the tank floor. Provide access for entry into the tank directly over SITE REQ PAGE 1 the pump location and extend 6" above final grade. The tank shall be properly sealed using 1" diameter butyl rubber pliable sealant as approved by the tank manufacturer. After joining, plaster along the joint with hydraulic cement, cement mortar, or other approved waterproofing sealant. The tank shall be provided with knock -out sections to accommodate the 4" diameter Schedule 40 PVC inlet piping from the septic tank and from the recirculating sand filter, as well as the 2" diameter electrical conduit. Seal around pipe using bituminous rope. . (f) Before backfill around tanks, and after all piping has been connected with and sealed against the tanks, all tanks shall be filled to the outlet level with water, and shall be observed for 24 hours for leakage. If the water level within the tanks has dropped more than 1/2 inch during the 24-hour inspection period, the tank leakage tests are considered to have failed, and the tank must not be used until the sources of the leaks have been found, the leaks properly sealed, and the tanks retested and the leakage tests being met, prior to backfilling around the tanks. Approved vacuum testing of the tank may be used in lieu of leakage testing. (g) The pump to be installed into the dosing tank shall be Goulds 1/2 horsepower WE0511H pump, Model #3885, or Hydromatic SP50M1 pump, or Myers WHRH5-11C pump, or Zoeller N161 pump, or approved equal. Such pump shall consist of 1/2 horsepower motor capable of handling 3/4" sphere solids, heads to 21.9 feet total, flows of 48.1 gallons per minute, and shall require 115 volts, single phase, 60 hertz, 16 amp service. (h) Extend 2 inch diameter Schedule 40 PVC piping from the pump located in dosing tank to the start of the distribution piping system at the top of the recirculating sand filter bed. See Engineering Plans for details. The end of the lateral shall be turned up and plugged with a Schedule 40 PVC removable clean -out plug. All joints in piping shall be of water tight connections such that the only source of water seepage from the system is through the orifices in the distribution piping system across the top of the sand filter bed. (i) The sand filter bed shall be constructed with dimensions approximately 25.00' long by 12.50' wide by 3.25" high. Excavate for the floor of the sand filter bed to a smooth and uniform surface, sloped to drain toward the underdrain outlet location. Provide 3" slope across the floor of the sand filter bed from the high corner to the outlet corner. Remove rocks, roots, and other sharp objects from the floor and walls of the sand filter bed excavation. Spread 2" thick layer of creek sand, free of trash, debris, and sharp objects over the floor of the prepared excavation, and rake to a smooth and uniform surface, ready to receive the moisture membrane. Along the edges of the sand filter bed, place 1/2" thick gypsum board against the side of the excavation to SITE REQ PAGE 2 protect the membrane from damage or puncturing, install one layer of 10 mil polyethylene film, similar to P-350 poly scrim by Poly Plastic & Design Corp. of Springfield, Mass. across the floor and up the sides of the filter bed. Install 1/2" thick gypsum board over the membrane at the walls of the bed. Spread 2 inch thick layer of fine sand over the membrane. Where the underdrain piping system passes through the filter wall, said opening shall be carefully cut in the membrane, and properly sealed around the piping, and shall provide a water tight seal at said location. Over the filter floor surface, install the 4 inch diameter flexible porous plastic tubing, similar -to Hancor Pipe or approved equal, to be used as underdrains for the sand filter bed, with holes placed downward. Connect tubing to 4 inch diameter Schedule 40 piping at the lowest corner of the sand filter bed wall where the piping system passes through the filter membrane wall, with said 4 inch diameter Schedule 40 PVC piping being laid at 1.0% minimum grade from the sand filter bed to its entry into the flow divider box, and from the outlet of the flow divider box to the inlet of the chlorination tank and dosing tank. Install stone of the 1 inch to 1 1/2 inch diameter size (#57 stone) around the underdrain piping system to a depth of 6 inches, and rake to a smooth and uniform surface. Over the stone base of the sand filter bed, install approved filtering sand to a depth of 30 inches (2.50 feet), and rake the top of the sand to a smooth and uniform surface. The sand to be placed in the filter bed must meet the specifications for filter bed sand as established be the N.C. Division Of Environmental Management.. The sand shall exhibit an effective size of 0.35 to 0.50 mm, shall contain less than 0.5 percent dust content, and shall demonstrate a uniformity coefficient of less than 3.0 which shall be computed by taking 60 percent passing by weight through a No. 14 sieve and dividing by 10 percent passing by weight through a No. 35 sieve. The sand supplier shall verify approval of their sand for use in sand filter beds by submitting a copy of a letter from the N.C..Division of Environmental Management granting their approval of said sand during the 3 month period prior to the date sand is delivered to the job site for this project. (j) Once approved filtering sand has been placed into the sand filter bed to the proper depth and has been spread to a uniform surface, the distribution piping system, shall be placed on top of the filtering sand, and connected with the piping system to the pump unit. (k) The laterals across the top of the sand filter bed shall consist of separate lines of PR160 1 1/4 inch diameter P.V.C. piping and each lateral shall contain orifices of 7/32 inch diameter size. See "Orifice Data Sheet" within these specifications for length of each lateral, as well as the number, size, location and spacing of all required orifices SITE REQ PAGE 3 n- per lateral. The first orifice shall begin as specified from the manifold pipe and subsequent holes shall be located at required intervals along the length of the pipe and shall be alternated from side to side as shown on "Typical Section. Through Lateral Trench." The ends of all laterals shall be turned up and plugged with a Schedule 40 PVC removable clean - out plug. All joints in laterals and in manifold piping shall be of water tight connections such that the only source of water seepage from the system is through the orifices. (1) Orifices shall be drilled into the distribution laterals at 4 o'clock and/or 8 o'clock position of the pipe, and shall be alternated from side to side along the length of each distribution lateral. A total of 5 distribution laterals of 1 1/4" diameter size and 23' length are required, and the total number of orifices in the distribution piping system shall be 47 orifices of 7/32" diameter. The distribution laterals shall be connected with 2" diameter Schedule 40 PVC manifold piping which extends from the top of the sand filter bed to the pump located within the dosing (pumping) tank. Once the distribution piping system has been installed across the top of the sand filter bed, the sand surface and distribution piping system shall be covered with a 6-inch thick layer of #57 wash stone, spread to a smooth and uniform surface. (m) Wastewater piping system from the underdrain outlet of the sand filter bed to the inlet of the flow divider box, and from the flow divider box to the inlet of the dosing tank and chlorination tank shall be 4" diameter Schedule 40 PVC sewer pipe laid at 1.0% minimum grade. (n) The flow divider box shall consist of two separate "flow divider" units as manufactured by "Flow Divider Company" of 10621 Six Forks Road, Raleigh, N.C. 27614, Phone 1-800-552- 1839, or approved equal. The two flow dividers shall be installed within a precast concrete box with access lid to be set above final grade. (o) The chlorine contact tank shall be 100 gallon capacity, cast of reinforced concrete material, with 4-inch diameter Schedule 40 PVC inlet and outlet piping, with baffles within the tank, and containing a "Sanuril" Model #100 tablet chlorinator, with stacking tubes to hold the chlorine tablets, and with removable tank lid over the Sanuril tablet chlorinator for easy access for checking and refilling the stacking tubes with chlorine tablets. Size of chlorine contact tank shall be 3.5' long by 3.5' wide inside dimension by 1.17' liquid depth. See detail for tank construction. (p) The step aerator system shall consist of concrete or masonry steps open to the atmosphere located in a structure 8'-0" long by 2'-0' wide, shall contain a total of 9 steps, with each step dropping 2 2/3 inches (one brick course) and each step containing one-half of a 2" diameter pipe split horizontally, and being 10" long each. At the bottom step of the aerator shall be a sump of 8-inches long by 8-inches SITE REQ PAGE 4 wide by 8" deep to be used as an effluent sampling port. Cover the step aerator with open metal grating. Piping from the outlet of the step aerator system to the discharge point in Lake Norman, shall be 4-inch diameter Schedule 40 PVC pipe laid at minimum grade of 1.0 percent. Piping shall be buried at minimum depth of 1.5 feet below grade from the outlet of the step aerator to the shore line of Lake Norman. From the shore line to its discharge point, a distance of 200 linear feet, the 4" diameter Schedule 40 PVC pipe shall be laid on the floor of Lake Norman, and shall be..threaded through the core of 8" thick concrete block units at intervals of 10 feet along its length. (q) The pump shall be operated automatically by use of Super Single Pump Switch, Model #15ssd, 115 v., or approved equal, equipped with a three -pronged series plug (configuration per NEMA5-15) for 1/2 horsepower pump and set for 5 1/2 inch start/ stop level adjustment. (r) Pump and control circuits shall be provided with manual circuit disconnects within a water -tight, corrosion - resistant, outside enclosure (NEMA 4X or equivalent) adjacent to the pump tank, securely mounted at least 12 inches above the finished grade. The pump shall be manually operable without requiring the use of special tools or entrance into the tank for testing purposes. Conductors shall be conveyed to the disconnect enclosure through waterproof, gasproof, and corrosion -resistant conduits, with no splices or junction boxes provided inside the tank. Wire grips, duct seal, or other suitable material shall be used to seal around wire and wire conduit openings inside the pump tank and disconnect enclosure. (s) The "Owner Warning Panel" shall be located at a conspicuous location within the building at a location as selected by the owner. The "Owner Warning Panel" shall contain the name, address, telephone number, and emergency phone number of the person to contact immediately should malfunctions occur and warnings be given by means of the "Owner Warning Panel". (t) The "Owner Warning Panel" shall contain a sign marked "Wastewater System Alarm". The Installation Contractor shall install a "Tank Alert" warning system by S.J. Electro Systems, Inc., of Detroit Lakes, MN. which shall consist of a float and alarm panel. Such "Tank Alert" shall be connected with a separate circuit from that supplying power to the pump. The alarm shall be mounted in a location approved by the Engineer which will insure it being easily visible and audible from a satisfactory location within the building. (u) All control and power wiring for the entire wastewater disposal system shall be in compliance with all local, state, and federal regulations, codes, and ordinances, and shall be confined on the site generally to the area of the pump, control floats, and "Owner Warning Panel". The Installation Contractor shall be responsible for the costs of obtaining SITE REQ PAGE 5 f n- all power and control wiring for this system and shall coordinate his work with the electrical contractor and with the Owner. (v) Once the proposed wastewater disposal system has been constructed and is ready to be placed into operation, the existing original septic tank and the existing dosing tank shall be uncovered, its contents pumped out and disposed of properly, and the tank removed from the site, with the tank hole being properly filled and compacted. (w) The Installation Contractor shall smooth the.disturbed land surface after installation of the wastewater treatment facilities, and shall leave the surface neatlyshaped to shed rainwater and ready for seeding. The Installation Contractor shall stabilize the area of construction by planting and seeding with Kentucky 31 tall fescue and shall keep the planted areas watered and mulched until such time that a hardy stand of grass is established. Prior to seeding, evenly distribute and mix with the soil 8-8-8 commercial fertilizer at the rate of approximately 40 square feet per pound (1,000 pounds per acre). For soils with a pH of 6.5 or less, hydrated agricultural.lime shall be applied at the rate of 20 square feet per pound (2,000 pounds per acre) and at a rate. of 40 square .feet per pound (1,000 pounds per acre) for soils with a pH greater than 6.5 as determined by -soil samples tested by the North Carolina Agriculture bepartment or as approved by the Engineer. Seed shall be sowed at a rate of 200 square feet of area planted per pound of grass seed and shall be raked lightly into the top 1/8 inch of soil, rolled lightly with a light weight lawn roller, and watered with a fine spray. (x) The wastewater system Installation Contractor shall agree to provide a minimum of one year of regular service to the occupant for maintenance and upkeep of this system at no additional cost to the occupant, and such one year period shall begin from the date of .final inspection and acceptance of the system construction by the occupant, the Engineer, and representatives of the permitting agency. After the above one year period has expired, the Installation Contractor shall offer the occupant a continuation of maintenance and upkeep service at a reasonable charge as may be negotiated between the Installation Contractor and the occupant. Such service shall include checking the entire system at least twice yearly, offering quick response servicing in case of a malfunction of the system (maximum of 24 hours after warning is given by the "Occupant's Warning Panel") and performing such servicing of components and replacing of worn or defective equipment as may be necessary to keep the system operating in good condition. In the event that the Installation Contractor will not be willing to agree to above described one year maintenance period, then any other time period must .be acceptable to the occupant, the Engineer, and to the permitting agency.. SITE REQ PAGE 6 WASTEWATER TREATMENT SYSTEM JANE.W..HOPE AND HAROLD P. HOPE, JR. DESIGN SPECIFICATIONS FOR WASTEWATER TREATMENT SYSTEM FOR EXISTING 3-BEDROOM RESIDENCE AT 123 LANGDON ROAD, DAVIDSON TOWNSHIP, IREDELL COUNTY, N.C. DAILY WASTEFLOW: SEPTIC TANK SIZE: PUMPING TANK SIZE: EFFLUENT LOADING RATE AT SAND FILTER BED: TOTAL SAND FILTER AREA: TOTAL LINEAR FEET AND DIAMETER OF LATERALS ACROSS TOP OF SAND FILTER BED: TOTAL LENGTH AND DIAMETER OF SUPPLY MANIFOLD: NUMBER AND LENGTH OF LATERALS ACROSS TOP OF SAND FILTER BED: MANIFOLD PLACEMENT: HOLE SIZE: TOTAL NUMBER OF HOLES: TOTAL FLOW THROUGH SAND FILTER SYSTEM (SEE ORIFICE DATA SHEET) ELEVATION HEAD: PRESSURE HEAD: FRICTION HEAD: TOTAL HEAD: STORAGE VOLUME IN PIPES: 360 gpd 1,500 gallons 1,500 gallons 4.608 gpd/sq. ft. at 4:1 ratio 1.152 gpd/sq. ft. as single pass 12.5 X 25.0' = 312.5 SF 115 feet of 1 1/4" diameter 80 feet of 2 diameter Sch 40 PVC 5 @ 23' each One end 7/32" diameter 47 orifices Disposal Field = 46.1 gpm Anti -siphon hole= 2.0 gpm Total 48.1 14.1 feet 3.0' 4.8' 21.9 feet Manifold = 13.9, Laterals =10.4 Total = 24.3 gals DOSING VOLUME: CHECK VALVE NEEDED: PUMP REQUIREMENTS: 180 gallons, 5 1/2" in 1,500 gal. tank 48.1 gpm at 21.9' TDH Use Goulds 1/2 horsepower WE0511H Pump, Model 3885, or Hydromatic SP50M1 pump, or Myers WHRH5-11C pump or Zoeller N161 pump, or approved equal PUMP RUN TIME PER DOSE 3 3/4 minutes L4 0 t'm0't �rnm bz y a�80p En 8 Hrov m 00zy � H � ro��d H 3 z z I��j �O OHCA �� tinzrnr r�r H O H En z rij x O O0 Cam+] H C7 ro En Z Cn H H r H Ul cn u LETTER IDENTIFICATION OF LATERALS LENGTH OF w �=' L' LATERALS co 00 OD OD w ELEVATION T O1 d1 T T OF LATERALS Ln to to to to W HEAD AT 0 0 0 0 o LATERAL w w w w w SIZE OF. N N N N N ORIFICE 0 0' 0 0 0 FLOW PER io io io io io ORIFICE 0o co co ao 0o ( 9 pm ) NUMBER OF i ko o w o ko ORIFICES PER LATERAL FLOW PER rn °D 'D °o 'D w LATERAL 01 d N O N O N (9Pm) 0 �-j 0 N DISTANCE FROM i i i MANIFOLD PIPE a_' "_' °_' TO FIRST ORIFICE ORIFICE N N N N N SPACING rn a, a, rn rn (on center) N o o DISTANCE FROM i j j j j LAST ORIFICE °_' °_' °_' TO END OF LATERAL � N � N �-' N �-j SIZE OF = LATERAL Ion= VQN= _y ELEVATION DATA AND FLOW LINE INFORMATION -CONCERNING PROPOSED WASTEWATER DISPOSAL SYSTEM TO SERVE EXISTING THREE —BEDROOM RESIDENCE AT 123 LANGDON ROAD, DAVIDSON TOWNSHIP, IREDELL COUNTY, N.C. 1. Prior to beginning construction of the proposed wastewater disposal system on this lot, carefully uncover the existing wastewater piping system to the existing septic tank, and verify that the existing wastewater piping system is contained within a single pipe and that its elevation will allow construction of the proposed wastewater disposal system_ at the elevations described herein. If the elevation of the existing wastewater piping system will not accommodate the elevations described herein, the Contractor shall notify the Engineer of his discovery, and the elevations of the proposed wastewater system shall be adjusted accordingly to the satisfaction of the Engineer. Do not start construction.of the wastewater disposal system components until the elevation and location of the existing wastewater piping system has been verified. 2. For the 1,500 gallon capacity precast concrete septic tank, set invert into tank at elev. 777.00, set invert out of the tank at elev. 776.83 (top of tank approximately elevation 777.83, bottom of tank approximately elev. 772.33). Top of r_ access hatch at elev. 780.00. 3. For the 1,500 gallon capacity precast concrete dosing (pumping) tank, set invert in at elev. 776.58, top of access hatch at elev. 778.50, top of tank at elevation 777.41, pump intake at elev. 772.41, bottom of tank at elev. 771.91. 4. For the recirculating sand filter bed 25.00' long by 12.50' wide, set top of stone cap at elev. 787.001, set top of filtering sand at elev. 786.501, set bottom of filtering sand at elev. 784.25' at high corner and at elev. 784.00' at low corner, set bottom of stone at underdrains and invert "Out" at elev. 783.50' at low corner (slope bottom of sand filter bed 3" from high corner to low corner), set bottom of bed excavation at elev. 783.17' at low corner. 5. Invert of 4" diameter Schedule 40 PVC gravity piping from sand filter bed underdrains as follows: Invert out of sand filter bed at elev. 783.50' 37 L.F. of 4" diameter Sch 40 PVC pipe at'1.71% slope Invert into first flow divider at elev. 777.17' Invert out of first flow divider at elev. 777.00' Invert into second flow divider at elev. 776.92' Invert out of second flow divider at elev. 776.75' Invert into dosing tank at 2 locations at elev. 776.58' Invert into chlorination tank at elev.-778.00' ELEVATION DATA AND FLOW LINE INFORMATION Page 1 of 2 ELEVATION DATA AND FLOW LINE INFORMATION (Continued) 6. At Chlorine Contact Tank, to be built 4'-0" long by 4'-0" wide by 4'-0" high outside dimensions, build to the following elevations: Top of lid over chlorine tank at elev. 780.42' Average grade at chlorine tank at elev. 779.4' Invert into tank/chlorinator at elev. 778.00' Invert out of chlorine tank at elev. 777.83' Floor of chlorine tank at elev. 776.67' Bottom of tank at elev. 776.42' 7. At Step Aerator and Sampling Port, to be built 2'-0" wide and 8'-0" long overall, build to the following elevations: Invert into box at first step at elev. 776.08' Build a total of 9 gravity steps/drops at a drop of one brick course per drop (2 2/3" high per drop), using half of 2" diameter pipe horizontally per step (drop). Invert out of step aerator/sampling port at elev. 774.08' 8. Invert of 4" diameter Schedule 40 PVC gravity pipe from the step aerator/sampling port to the discharge point: Invert out of step aerator/sampling port at elev. 774.08 Invert out at discharge point at elev. of lake bottom. Extend discharge point a distance of 200 feet into Lake Norman from the shore line. Install pipe through 8" block masonry units at 10' intervals along the bottom of the lake to the final discharge point. 9. In dosing/pumping tank, set float switches at the following depths in the tank: Pump "OFF" float at 1'-5" above tank floor Pump "ON" float switch at 1'-10 1/2" above tank floor Alarm "ON" float switch at 2'-1 1/2" above tank floor ELEVATION DATA AND FLOW LINE"INFORMATION Page 2 of 2 RECOMMENDED SCHEDULE FOR SYSTEM MAINTENANCE,'OPERATIONS, AND MONITORING OF RECIRCULATING SAND FILTER WASTEWATER DISPOSAL SYSTEM 1. The chlorination tank should be checked at least weekly, the amount of chlorine tablets in the chlorinator should be observed and tablets added as may be necessary to maintain an adequate supply of chlorine for proper. disinfection. Check chlorine residual of effluent leaving the step aerator in order to determine that the proper amount of chlorine is being fed into the system (0.5 to 1.0 ppm). 2. Pump and control float operation should be checked during all routine inspections and at least twice monthly. 3. Pump maintenance should follow the manufacturer's recommendations. 4. The septic tank should be checked periodically for sludge accumulation and should be pumped out as needed with the sludge being disposed of properly. Check yearly if garbage grinder is included within the wastewater system (not recommended) or check.every three years for systems without garbage grinders. 5. Accumulated solids in the laterals over the sand filter bed should be back flushed annually by unscrewing the caps of each of the turn -ups and back -flushing with a garden hose using clean water, or by flushing the lines by use of the pump in the dosing tank. 6. Leaking plumbing fixtures should be corrected as soon as possible. . PREPARED BY: DAVID A. ROBERTS, P.E. OF.LANDIS,.N.C. Provide Manual Disconnects For Pump and Control Circuits in Water -tight,. Nema 4 X outside Enclosure ----� Non -Corrosive Conduit or underground Cable High Water Alarm Cord _ High -Water Alarm Cord to Panel in House From Septic Tank Pumping Tank Level Control Unit Cord r-- Pump Power Cord ,�IWV 1%LZ-TTe.yg V%6 Scu 44 Pvc M I� Q i N � r BAFFL.M WALL wrr" Two 410 opa+llMC-,S -SET Iv Asam FLOOR Two-2" Concrete Blocks Placed Side by Side WA\-rw,P og Cover Box Threaded PVC Union 9 NOW III�1� Riser at.least 6" above -- GATE VAa.N/g grade PVC (or Bronze) Nylon lifting Rope = T14 ScH 44o Pvc -M SAMV FLLT= MD _*j role, to break sipho: on of pipe _ High Water Alarm Float _ "Pump On" Float Contro Draw -down level "Pump Off" Float Contn — FLopT 'jYi.��Sil�pE1Z11LItJ5pE1 SAI!o" CONG MLJXK WI_n4 VOIAs r-lu b WITH Cow'. Submersible Pump ru tap i uywE m v as'si M41, M W N : so m IDN ,,,••hnnil IN�``� 0 w EQ a H w A w U NOW III�1� Riser at.least 6" above -- GATE VAa.N/g grade PVC (or Bronze) Nylon lifting Rope = T14 ScH 44o Pvc -M SAMV FLLT= MD _*j role, to break sipho: on of pipe _ High Water Alarm Float _ "Pump On" Float Contro Draw -down level "Pump Off" Float Contn — FLopT 'jYi.��Sil�pE1Z11LItJ5pE1 SAI!o" CONG MLJXK WI_n4 VOIAs r-lu b WITH Cow'. Submersible Pump ru tap i uywE m v as'si M41, M W N : so m IDN ,,,••hnnil IN�``� 0 w EQ a H w A w U ?14&T TRIG —� 1.00E ��7-yii�'1� IPM voi P ally .811x ►�.� Cs�IJG. P1Q',K Q q 1=t�-L bolos o Wlru cam FLOAT TREE DETAIL PREPARED BY DAVID A. ROBERTS4 P.E. NO SCALE 0 p4G PIpm SLIDC 211¢� p1F% ow WTo 2y"o RJMPtt.IG -M"K FLooR c Jot n F1 , It C,Ogc,. AR wt> j PI P& �c i40 •ter ♦ e a 4 L 11 ¢1.. �'Su t+1 *� N1 W caLC 5 ' (JOrA. SAS Cr- 1.1 N JE Z P x F r 33 It TOP FILTOR BMP Top S ro► F- F1Av= I 2k1A-rmr� ALL — , I LOps x I. r wIvV, cItZCu"T)lV6 Na F1Lim 13*0 ` '/4"b PP,-IGa Qvc. LmToerzew�s 'LoN(*-5 RjeQO -- 1Os-n« �� •�I32�� ��1 Cie t� s �►s Q, SU4 4P PVC GRAN IT' Fl P1 NC7 To r-AovJ D►u1Dp�o�c �p �"` Z Scl-� Q V C ► nq N� oc.n P P��. F o-r, k i s\ Fi i -r,z o 6` i1-3 2L(1, ZIL (' C. G 1 1(-3,. _ v�ITM TUnrr-uQs AT ENoa— 5 RQ`�o rl Owl .vo Ti is c d a a o v a v a n a =T Sep C a a r — 6"aF 57- wNIAL 0 SIM C . _ /2 �.yPSurt\ DcAa a4 EACA Sly of v o2 Ul e.& =• looa , • ' � r � - �'' of # 5 � wAaH�'sT�N� - 4POROUS P�asi�c T A a a �, o ab,a e3 u �, 11 I A A it D 0• p' ' s p .. ,a -Ska Pt. �aTrorr\ OF SANio F1 Lum Goo 3" Fworn �; MIS �f+Y KEt, lrtf AaA2� w:f� �•11 �l coup Tc !.Ow =14IG14 •-CMMR-:ate .pJMI T84 -J CR05S SEC-Tloti "A-k" TN?Zdy6A RF.ClRC.ULA-rlS . Sw4a r'IL`C' a Up 4"-s Scc•IacuLz Ao pvG AM (.o1� M I ► 1. swPE� 'I A Z r.; it FROM swD Fium.R BSD 4"<� sf--" aUW- qo pvG AZ' 1.,o M4.1• 'W-9m,7m, `wr To PUMF I1.1G I i 411,$ f.+CMili. lLL� py� AT t.o • MI • 5��� - TO SAP AERATOR AND i— sr�rnp��� P�Rr PLAN VIEW ��nnou�,gLc �.Iv FLOW vivIDrRs 4`0 FVG INS/ I it . 1 uV oU i -.,/ rl NV I" �I IJV FLOW DIVIDER 13OX DETAILS PREPARED BY.: DAVID.A. ROBERTS.,. RE, SCALE: I" I'-0" DATE: 5-30-95 79£ K CR pRW Si r�0 . Gt�IT YJ�S lot 1 1 Comexua .E SLAS N CARO��••, SEAL 9 6271 a Iy S� �vGIN���'��� ` rHUR'wo,,,. ILO �-- FRS rr Fi. w O tVvo rt 4 SOV4 fit =vL UNA 2�tA�r1 30 I r 3'' PrMa .j D+ Sc►iw26 0 ���C�{° x 4' CoNc, TANk-.ouzs� D+ r Ns�vn►s - 3„ ki ra�� Tw c.y t4*,s.S 5CA 4o-Fvc. //4,-er 'eft ,' O ��SRt1V�IL �cOL�L {�0 Tr,�3t1�T GNftaR�oJAT�fL^"rr�auN'C �N �YQ��pVC l,�.GS j i i �d rJ J�IAPD � L-VO i - O Ob lMS (o� _ h%*M yljd3 ' a `O �� s�� �� ,•.' � �"•, N'�t'D +f .1, 'r►ttrl ►r � ����nd4;,�/,I N4.1Nnc�u _?�cx�n�•uo�t1+� ,L�e'��.�'j„+ oaf Z�.�w-t,�?��NdS 0 -A-3cria, @ 5dp1S'"t9Nd{{�� ��2f��XZf,I �,tM crti7 aela7d, 71at+� "'v►tC�{��/► �Sn O �Ih-�v1Ncr� ar�vc*�r� ta�nobnl ,{b~�w�. Nall.S.Ss 3 lug I �,t �! 1-'Z-►iLL =1r3T3 n a " � I I u' Q :b nA ea 4� 6� 4" - ISc+�.F o+= 2'� Sctii 4o QYc. Pik-SP�ttWo�zor�-mvY-�x�rhj2' To oloo "C It N a SA" L3 N 6 FOft'f _ ]3RICIc TRfAOS—$�ON�o ��— IORfQ�'D _ 1 LAN � IOW EJJ _ -r-r.t T p t�K S� Pf �2T S er f U G PA ri Ncr 14m ir- OF r-"4) A19E - F-wrA p Zcacti "Ik. � / l 5ET Top ov PiP.%—, rcujR wlTA 14RIC-14, — - RjsERsc:Z Z�%3 C I ORIc►c coulaxt t gcN IWV cu-r — SarpL,v4(. �0�7 A�RATo1, LI N Q PJRT I ' 0 • For Homes • Farms • Trailer courts • Motels • Schools • Hospitals • I ndustry • Effluent Systems anywhere effluent or drainage must be disposed of quickly, quietly and efficiently. Heavy -Duty Solids Handling Dependable Capability to 3/4" 1/3, 1/2 H.P. 60 Hz Single Phase 115, 230 Volt. 1/2, 3/4, 1, 1 1/2H.P. 60 Hz Single Phase 230 Volt. Three Phase 208-230, 460 Volt. 90 80 ~ 70 w W 60 Q = 50 U 40 Z 0 30 J Q 0 20 10. 0 0 °S S$ t x.. k t f e '� '4 t .. YL �a .. ' f�T°' 1..:� a 4 can Y •t i.s r fi �y A 1 }4�• a��. �.T. �� tat. .+. i�r1 -�5 K b� lY �%�.r � ��•i _ rr. � A � ry ��S r. � q 1NEt f 6- r�� hhtiMODEk +3885?r" ,r i+L. «� t .'� s tA' Tik } fi. . W, < � iv..rz' ° t ki ihRPM ?'S1yf50�345rT �k° N r itr .>...i„2x:! 1,, i . ,, rn t', ���.:-.- .1,,� F'f&Y;;• ,w '^,�f t " ".%�*' �• � �a..i Ja:V3 .�'p�-�5 7 r"�3. 11� Ski' i 1 .�,!5 �£ �1 `. `2.'. 4 4 '�fy 4k5�1; N ; ;;t tF j`x ii% �J r . r�" ftIV L is h ;' f fr r`f� s' : 7f'! ,. , . i a 8• ;4' .'`>,' 9\;tlj Bulletin CL2.1A July 8, 1983 GOULDS Model 3885 (Supersedes Model 3870) Submersible Effluent Pumps Pump Specifications Solids Handling Capability to'/4". Discharge Size 2" .NPT. Semi -Open Impeller 3 vane design, threaded on shaft. Three phase units use impeller locknut to prevent accidental back -off. Pump out vanes on backside of impeller for protection of mechanical seal. Casing Volute type for maximum efficiency. Stainless Steel Fasteners Series 300 stainless steel for corrosion resistance. Mechanical Seal Ceramic vs. Carbon sealing faces, stainless steel spring and Buna N elastomers. Maximum Temperature 160° F. Capable of Running Dry without damage to components. Motor Specifications Motor Fully Submerged in high grade turbine oil for permanent lubrica- tion of bearings and mechanical seal and efficient heat dissipation. Motor sealed from environment by rugged cast iron enclosure. Bearings Heavy-duty all ball bearing construction. Stainless Steel Shaft Series 300 stainless steel for corrosion resistance. Threaded shaft. Single Phase Units All single phase units have built-in thermal overload protection with automatic reset. Three Phase Units Overload protection in starter unit. 208-230 or 460 volts. Threaded shaft 60 Hz operation. Power Cord Water and oil resistant. Epoxy seal on motor end acts as a secondary moisture barrier in case of darnage to outer jacketing. Corrosion resistant gland nut. Single Phase Units '/.,. '�- H.P. models equipped with 15' of 16 3 SJTO with 3-prong grounding plug. '.,, 1. l': H.P. models equipped with 15' of 14/3 STO power cord. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. 10 20 30 40 50 60 70 80 90 100 110 120 GALLONS PER MINUTE [qGOULDS PUMPS, INC. SENECA FALLS NEW YORK 13148 GOULDS Model 3885 Submersible Effluent Pumps RQECIFICATIONS _.P. Order No. Volts Phase -Max. Amps RPM Max. Solids Wt. (lbs.) 1/3 WE0311L 115 1 9.4 1750 56 WE0312L WE0311M 230 4.7 WE0312M i/ WE 5511H 115 16.0 3450 60 WE0512H 230 8.0 WE0532H 208/230 3 3.4 WP0534H 460 1.7 3/4 WE0712H 230 1 9.0 70 WE0732H 208,1230 3 5.4 WE0734H 460 2.7 1 WE1012H 230 1 11.6 WE1032H 208/230 3 6.4 WE1034H 460 3.2 1 V2 WE1512H 230 1 13.3 80 WE1532E 208/230 3 92 WE1534H 460 4.6 DIMENSIONS CHART (in inches) H.P. Order No. Phase A B C D E F ��3 W E0311 L 1 81/ 12 Ye 5'/4 15 31/4 2 WE0312L W E0311 M W E0312M i1 Z W E0511 H WE0512H WE0532H 3� WPO534H 3/4 W E0712 H 1 38 8112 121! 53/4 15 31/4 2 WE0732H W E0734 H WE1012H WE1032H WE1034H 1112 WE1512H WE1532H WE1534H Model 3885 Packaged Effluent Ejector System KICK -BACK T _f FEATURES "Tornado'' recessed type open impeller is non -clogging and has no close running clearances. The recessed impeller, open volute construction is dependable and trouble free, thoroughly proven in hundreds of field applications. Motors are submersible type permanent split capacitor. 3450 RPM, and oil filled for best heat transfer and bearing lubrication. Motors have no start relay or other starting devices and cord plugs directly into standard receptacle for manual operation or can be used with Myers ALC or AWS level controls for automatic operation. Motor has automatic reset type overload protector attached to motor winding. Available for 200 or 230 volts single phase power also for 115 volts for 1/2 HP size. Power cord is 20 ft. long with SJTW insulation and grounding -type molded on plug. Pump discharge uses same flange as WHR series and is supplied with 2" NPT pipe flange. Three inch flange is available if required. A lift -out rail system is available for use in septic tanks or deeper basin installations. Sealed pump and level controls are designed especially for underground wet pumping applications. No open switches or vent cords to give trouble. APPLICATION The Myers WHRH series Waste Handling Pumps are an extension of the WHR series line and provide higher pumping heads and higher horsepower but still handle 11/2" dia. solids. Many pumping applications for sump or sewage handling service require higher heads due to long discharge lines, higher elevations or both. These WHRH pumps are furnished for simplex or duplex systems using the same basins, covers, controls and control boxes used with WEIR series pumps and listed in section 512. A lift out rail system with sealing flange is available for these pumps which allows pump to be removed from basin or septic tank without disconnecting any piping. Pump in Raised Position r v- CONSTRUCTION FEATURES Power Cord —Single phase cord is 20 ft. long with SJTW insulation and has molded on grounding -type plug. Plugs directly into standard receptacle, requires no control box. Used with ALC or AWS level controls for automatic operation. Cord Seal Bushing —Cord is potted into steel connector with polyurethane resin for leak proof seal. A cord nut and rubber grommet clamp the cord into the bushing. Cord can withstand a pull of 100 lbs. without loosening connection. Motor — Permanent split capacitor -type is oil filled for best heat transfer and bearing and seal lubrication. Operates at 3450 RPM and has built-in automatic reset overload protection. Motor voltage 200 or 230 volts single phase also 115 volts for 1/2 HP size unit. Capacitor Housing —A separate housing permits mounting of the permanent oil capacitors. Can replace capacitors without dismantling motor or pump. Motor Housing —Cast iron stator is pressed in for best heat transfer and alignment. Impeller— Bronze, Tornado non -clogging type. Has back pump out vanes to protect seal and reduce thrust. Mechanical Seal — Heavy duty type has carbon and ceramic faces lapped to a flatness of one light band. Spring and all seal parts stainless steel. Rubber seal bellows is Buna N. Volute Case —Cast iron has 11/2" full open volute to pass solids. Support legs provide proper clearance for pump inlet. Bearings —Lower ball bearing takes radial and down -thrust loads. Upper sleeve bearings take radial loads and have thrust washer to absorb any up -thrust. Corrosion Resistance —All iron parts are coated inside and out with baked -on epoxy paint. All machined surfaces are re -coated with epoxy after machining. DIVISION OF F. E. MYERS CO.QA McNE1L 400 ORANGE STREET. ASHLAND. OH 44805C 0 R P 0 R AT 10 N Power Cord . Cord Seal " Bushing r ,r Potted JI.. Leads ' Capacitor Housing _. Motor Housing Pump Shaft Bearings Motor Mechanical Seal=°Fasteners Motor Bottom Plate Impeller 1. Volute k Case ' PERFORMANCE CURVES WHRH SERIES WASTE HANDLING PUMPS CAPACITY LTTERS PER MINUTE a 60 so too 120 CAPACITY GALLONS PER MINUTE 000 T 24 22 20 e III 0 `QUAL/rY PUMPS SNCL- IA31779 Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. t Z27ZLIAR fff; MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347 SHIP TO: 3280 Old Millers Lane • Louisville, KY 40216 (502) 778-2731 • FAX (502) 774-3624 COMPARE THESE FEATURES • Non -clogging vortex impeller design. • Float operated, submersible (NEMA 6) 2 pole mechanical switch. • On point 14" Off point 511. • Durable cast construction. Cast iron switch case, base, motor and pump housing. • 20 foot UL listed 3 wire neoprene cord and plug. Longer cords available in lengths of 25-35-50 feet. • Automatic reset thermal overload protec- tion. • Oil filled motor - hermetically sealed. • Carbon and ceramic shaft seal. • Maximum temperature for effluent or dewatering, 1300 F. 540 C. • RPM 3450, 60 cycle. • Major width 14". Height 19". • No screens to clog. • Stainless steel screws, bolts, float rod, handle guard, arm and seal assembly. • Passes 3/4 inch spherical solids. • 11/2" NPT discharge with 2" or 3" flange available. • *163 and 165 UL and CSA listed. BRONZE VORTEX IMPELLER ZOELLElf MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347 SHIP TO: 3280 Old Millers Lane • Louisville, KY 40216 (502) 778-2731 • FAX (502) 774-3624 Manufacturers of .. . (ze `QUAL/rY PUMPS .FhVCr 1PJg FM0460 0590 0 Supersedes 00 1189 "161" - "163*" - "165*" Series ('/Z HP) (1/z HP) (1 HP) HIGH HEAD "FLOW MATE" FOR SEPTIC TANK SYSTEMS EFFLUENT OR DEWATERING PUMP SUBMERSIBLE 11/2" NPT DISCHARGE STANDARD 2" AND 3" NPT FLANGE AVAILABLE * UL LISTED Cemcf * CCanadian MEMBER Standards Sump 6 Sewage Assoc. Pump Approval Mfg. Assoc. available SSPMA Specification NSC-1225 MODELS AVAILABLE • Automatic or Non -Automatic 161-163 Series 165 Series • 1/2 H.P., 1 Ph, 115V, • 1 H.P., 1 Ph., 200-208V 200-208V or 230V or 230V • 1/2 H.P., 3 Ph., 200-208V, • 1 H.P., 3 Ph., 200-208 230V or 460V 230V or 460V NOTE: No UL listing or CSA approval for 200-206V 1 Ph (except Model 165) or Extra Duty (ED) pumps. TOTAL DYNAMIC HEAD/FLOW PER MINUTE FFFI t1FNT AND nFWATFRING rn W W 28 90 i 24 80 70 20 c� 60 } 16 50 0 12 40 0 30 8 20 4 10 163 HEAD/CAPACITY CURVE 161. 163 AND 165 SERIES fl 161 0 U.S. GALLONS 10 20I 30 40I 50 60I 70 80I 90 100I110 LITERS 0 80 160 240 320 400 FLOW PER MINUTE Standard all models - Weiaht 77 lbs. - 20 ft. cord - 1/2 H.P. 161 MODELS Control Selection Model Volts -Ph Mode Amps Simplex Duplex M161 115 1 Auto 15.5 1 or 1 & 9 uiSi 115 1 Non 15.5 2or2&B 3or5&6 51 230 1 Auto 7.0 1 or 1 & 9 51 230 1 Non 7.0 2or2&8 3or5&6 F161 230 3 Non 4.0 2&4 3&4or5&6 • H161 200 208 1 Auto 8.2 1 & 9 • 1161 200-208 1 Non 8.2 2 & 8 3 or 5 & 6 •J161 200-208 3 Non 2.2 2&4 3&4or5&6 •G161 460 3 Non 2.0 1 2&4 3&4or5&6 Standard all models - Weiaht 77 lbs. - 20 ft. cord -112 H.P. 163 MODELS Control Selection Model Volts -Ph Mode Amps Simplex Duplex M163 115 1 Auto 15.5 1 or 1 & 9 N163 115 1 Non 14.0 2or2&8 3or5&6 D163 230 1 Auto 7.0 1 or 1 & 9 E163 230 1 Non 7.0 2or2&8 3or5&6 F163 230 3 Non 4.0 2&4 3&4or5&6 • H163 200-208 1 Auto 8.2 1 & 9 ° 1163 200-208 1 Non 8.2 2 & 8 3 or 5 & 6 ' J163 200-208 3 Non 2.2 2 & 4 3 & 4 or 5 & 6 G163 460 3 Non 2.0 2&4 3&4or5&6 Standard all models - Weight 77 lbs. - 20 ft. cord - 1 H.P. 165 MODELS Control Selection Model Volts -Ph Mode Amps Simplex Duplex D165 230 1 Auto 9.8 1 or 1 & 9 E165 230 1 Non 9.8 2or2&8 3or5&6 F165 230 3 Non 6.6 2&4 3&4or5&6 ° H165 200-208 1 Auto 10.7 1 & 9 ° 1165 200-208 1 1 Non 10.7 2 & 8 3 or 5 & 6 J 165 1 200-208 3 1 Non 7.0 2& 4 3& 4 or 5& 6 65 1460 3 1 Non 1 3.3 1 2&4 1 . 3&4or5&6 SERIES 161 163 165 FT. M. Gal Ltr Gal Ltr Gal Ltr 5 1.52 106 401 61 231 61 231 10 3.05 100 378 61 231 61 231 15 4.57 91 344 60 227 60 227 20 6.10 82 310 59 223 60 227 25 7.62 74 280 57 216 59 223 30 9.14 65 246 55 206 58 220 40 12.19 46 174 46 172 55 206 50 15.24 21 80 33 125 51 191 60 18.29 15 57 43 161 70 21.34 30 114 80 24.38 14 53 90 27.43 100 30.48 LOCK VALVE 56' 1 66' 87' 655- r- n 4% 1'4 - 11'A NPT o `Y - 11'A NPT (OR( 7-B NPT I SELECTION GUIDE 1. Integral float operated mechanical switch, no external control required. 2. Single piggyback mercury float switch or double piggyback mercury, float switch. Refer to FM0477. 3. Mechanical alternator "M-Pak" 10-0072 or 10-0075. 4. Combination starter. Refer to FM0514. 5. See FM0712, for correct model of Electrical Alternator, "E-Pak". 6. Mercury sensor float switch 10-0225 used as a control activator, with "E-Pak" alternator, 3 or 4 float system. 7. SIMPLEX CONTROL BOX 10-0050, 115/230V, 1 Ph. max. 2HP use one(1) single piggyback wide angle mercury float switch OR two (2) 10-0225 mercury sensor floats for level control. 8. Four (4) hole "J-Pak", junction box, for watertight connection orwired-in simplex or duplex operation. 9. Two (2) hole "J-Pak", junction box, for watertight connection or splice. *No Molded Plug ormation on additional Zoeller products refer to catalog on Combination Starter, FM0514; CAUTION Piggyback Mercury Switches, FM0477; Electrical Alternator, FM0486; Mechanical Alternator, All Installation of controls, protection devices and wiring should be done by a qualified FM0495; Alarm Package, FM0513; Sump/Sewage Basins, FM0487; and Simplex Control Box, licensed electrician. All electrical and safety codes should be followed Including the most FM0732. recent National Electric Code (NEC) and the Occupational Safety and Health Act (OSHA). RESERVE POWERED DESIGN For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump. I ' F —_ 1 S P40 SP50 csnu�a Y[YI(ll Outstanding Features BULLETIN 210.8 S P40 — 4110 H. P. SP50 — 112 H.P. Residential sewage ejector submersible & high capacity sump service HYDROMATIC PUMPS A Marley Pump Company ■SP40 and SP50 pump systems rate high in efficiency for high capacity handling of sewage from large residences and buildings, drainage water from basements, dairies, stores, and industrial pumping of wastewater. ■4/10 horsepower (SP40) and 1/2 horsepower (S-P50) motors are ball bearing design, oil filled and protected with auto- matic reset thermal type overload. Motor housing filled with dielectric pure, clean insulating oil. Three phase motors do not have overload protection and should always be used with a magnetic starter incorporating overload protec- tion. 010-foot power cord with 3-prong grounding plug furnished as standard (autos only). 20-foot length available at extra cost. ■SP40 is high capacity, non -clog; two -vane sewage type. SP50 is'semi-open two -vane sewage type with impelling vanes on back shrouds to prevent stringy materials from binding blades or wrapping around shaft. CAPABILITIES ■Precision mechanical seal prevents leakage into motor. Seal faces are carbon and ceramic, super lap- ped for long leak -proof life. ■AII pump parts and motor housing are cast iron. Pump and rotor shaft are corrosion -resistant steel. All bolts and screws are stainless steel. Bronze- construction available on request. ■Diaphragm type pressure switch enclosed in water- tight housing, mounted to pump. Switch diaphragm is isolated by oil which is sealed in with a second dia- phragm. ■Choice of automatic or manual models. ■Each unit is given a complete pumping test before f leaving the factory. Specifications 4/10 HP 1/2 HP Capacities To: 120 GPM 150 GPM Electrical: 60 HZ 10 30 115V, 9.4 Amps 230V, 4.7 Amps 115V,.12.0 Amps 230V, 6.0 Amps. 230V, 2.7_Amp6 460V, 1.4 Amps. - 230V, 3.8 Amps 460V 1.9 Amps Solids Handling: 1-1/4" 1 . 1-1/2" Discharge NPT 2" Std., 3" Flange Optional - Pump Cord 10' Std., 20' Optional Controls Automatic and Manual Constructive Cast Iron Std., Bronze Optional SP40 Performance and Dimensional Data 28 24 20 W W LL = 16 O Q W 2 12 F r 8 4 0 SP40A — MAX SOLIDS 11/4" SPHERE — 1750 RPM 0 20 40 60 80 100 120 NOTE: CASTING DIM. MAY VARY _ W U.S. GALLONS PER MINUTE SP50 Performance and Dimensional Data SP50 — MAX. SOLIDS 11/2" SPHERE — 1750 RPM 28 24 20 w w LL z 16 Q W 2 12 O 8 4 0 U.S. GALLONS PER MINUTE Distributed by Bulletin 210.8 Rev 11/84; Supersedes 210.5 Printed in U.S.A. FULL LOAD AMPS AT 16 115V. 12.0, AT 230V. 6.0. FULL LOAD AMPS AT 30 230V. 3.8, AT 460V. 1.9 I I I 12n 14n z 51.. I �`. IIh, is t 1 ,2"13" . t ' '., gTD. PIPE e 1 ?•IN r NOTE CASTING bIM MA1} VARY a'H'� �' ,y MARLEY THE MARLEY PUMP COMPANY ✓% IL HYDROMATIC PUMPS Box 327. Ashland, Ohio 44805 (419) 289.3042 In Canada - Marley Fluid Systems, 126 East Dr., Brampton, Ontario L6T 1C2 International Sales - Mission, KS Telex 716875045 MARLY t1W I]U:3:Wy1► rciI=,11Ji1 A Low-cost Switch Designed to Outlast the Pump it Controls ADVANTAGES�o.__ �Service calls reduced with trouble -free j� switch (failure rate of less than one-half (D of one percent) b,.f�`` * Easy installation, no control panel is needed CH* Pump stuttering is eliminated with patented on -off ° tumbler — Not sensitive to rotation * Leakage problems are avoided with sealed water- proof and weatherproof non -corrosive float as well as epoxy -sealed cord conductors * Controls pumps of high -starting currents * Entire unit (control as well as cord set) UL listed and CSA certified * Two year limited warranty * Manual pump operation possible U.S. Patent Number 4302641 Mounting Clamps Applications: The Super Single Pump Switch provides automatic pump operation when con- trolling lift pumps, sump pumps, solenoids, relays, and alarms in non -potable water and sewage systems. Description: The Super Single, Pump Switch con- sists of one float, a cord with piggy -back plug (plug is optional), a mounting strap, and two ,rlounting clamps. Features: The Super Single Pump Switch will directly -control pumps to one HP 120V or two HP 230V. This pump switch utilizes a special heavy- duty, mercury -to -mercury type capsule (two pools of mercury make and break electrical con- tact). This patented on -off tumbler is omnidirec- tional; therefore, the float is not sensitive to rota- tion (no "up" side). This no "up" side feature simplifies installation. SSD, "ON" POSITION — MERCURY -to -MERCURY CONTACTS CLOSED SPECIFICATIONS FOR SUPER SINGLE PUMP SWITCH Model:* 15 SSD 120V W-P 15 SSD 230V W-P Pump down 15 SSD 120V or 230V W-O-P for emptying 15 SSU 120V W-P 15 SSU 230V W-P Pump up 15 SSU 120V or 230V W-O-P for filling *Explanation of model numbers: 15 SSD or SSu 120V or 230V W-P or W-O-P Cord Super Super Voltage With Without Length Single Single Piggy- Piggy - Down Up Back Back Plug Plug Please note: The Super Single Pump Switch Model 230V With - Plug is available in 15 and 30 foot cord lengths only; however, the 120V model may be ordered With -Plug in cord lengths of 10, 15, 20 and 30 feet. Super Singles with -out -plug (for direct wiring) may be used in either 120V or 230V application. VV-O-P models are available in other cord lengths. (Specify length desired.) Cord: Flexible 16ga.2conductor (U.L.) SJOW.A-SJOW (CSA) with molded piggy -back plug. Float: 3.375 inch diameter X 4.25 inch long thick -wall, non -corrosive ABS plastic for use in liquids up to 1500 F. Electrical: 1 HP Max-120V A.C.—single phase 2 HP Max-230V A.C.—single phase When SSD float is tipped When SSD float is tipped up, Note: One Super Single Control may be wired to operate relay con - down, mercury remains in mercury moves to contact non -contact position. position. trol panels for larger pump applications. 0 MAN IRM MR Ma MR a s SW This product has been carefully designed and manufactured using only materials of the highest quality. S. J. ELECTRO SYSTEMS, INC. cares about the CONSUMER and stands behind this product with a Two -Year Limited Warranty. A ffA WA FF A FE K M FM K FM K FM FM It FM FM K K K M K FMvv ! INSTALLATION DIRECTIONS, Model SSD & SSU Follow these steps: 1. Decide on pumping range for your installation. 2. After determining your desired pumping range, refer to Figure A and Pumping Range Table listed below. Note that tht pumping range is determined by the cable length from the mounting strap to the float. (To insure proper operation, this length should be at least 3.5 inches.) 3. Attach float cable to large strap (see Figure B) using the two small clamps. Space small clamps apart a minimum of one inch on each side of clear friction pad. Then fasten the'large strap securely to discharge pipe or other similar mounting. (The enclosed large strap and small clamps are releasable which permits readjustment or removal of either strap or clamps -note Figure C.) 4. Insert 120V piggy -back plug into 120V outlet or 230V piggy -back plug into 230V outlet. To avoid electrical hazards and corro- sion problems, electrical outlet must not be located in pump chamber. 5. Plug pump into piggy -back plug. ( Figure D) Check your installation. Allow pump to cycle once to insure proper pump range. Note: For direct wire installation (without piggyback plug) refer to Figure E. S. J. Electro Systems, Inc., can not be responsible for damages caused by the faulty or negligent installation of this control. If you feel that you may encounter problems in installing this device, we respectfully suggest you engage the services of a competent plumber, electrician or qualified service person. FIGURE A FIGURE B FIGS � - For piggyback plug installation Cable length Manual pump operation possible by plugging Pumpcord (see pump range table below) pump directly into outlet. Piggy back plug till Piggyback Ach PlugAutomatic Manual ' Operation Operation Pumping �� / Warning: For 230V Piggyback Plug Installations: Range �� In a 230V pump installation, one side of the line going to the pump is always "hot". This condition exists regardless of whether the switch is on or off. To avoid hazards, remove piggy. FIGURE C back plug from receptable before installing or servicing pump and/or switch. Pumping Range Table Cable length from mounting Approximate strap to float Pump Range 4- To release, grasp head, press tab back and pull head. Cable tie pulls free quickly, easily. Reusable. 2.5" above strap 3.5" 5.0" 2.5" below strap 3.5" above strap 5.0" 7.0" 3.5" below strap 4.5" above strap 7.0" 9.0" 4.5" below strap 9.0" 12.0" 6.0" below strap 11.0" 14.0" 7.0" below strap 8.0" above strap 13.0" 17.5" 9.5" below.strap bove trap 8.5"abelowsstrap 15.0" 20.5" 112.0' 9.0" above strap 17" 23" 14.0" below strap FIGS E - For Direct Wire Installation (See Diagram Below) . To unction Box ter To Pump White Switch Black To Pump Load Warning: For 230V With -Out -Plug Installations: In a 230V pump installation, one side of the line going to the pump is always "hot". This condition exists regardless of whether the switch is on or off. To avoid hazards when installing or servicing, install a double pole disconnect near pump installa- tion. 91R.RA7.1'117 AAfn In- C 1 tZI-4-C. +e 1- 04 1 Ell- 17 n,.+....:a 1 �1. 11At,1 c,rnl I Irn An Economical, Easy -to -Install Complete Liquid Level Alarm System SENSOR FLOAT ALA c _ o Switch 14 NII \T.,.-1 O..aa.... Warning Light Install Inside Bu ADVANTAGES * U L listed *Warns of high or low fluid levels by activating horn and warning light *Easy installation *Metal alarm panel *Mercury switch and cord encapsulated in epoxy and impact -resistant, non -corrosive ABS plastic with internal stabilizing weight. *Low cost *Two-year limited warranty Applications: The Tank Alert is a revolutionary SPECIFICATIONS FOR TANK ALERT high or low fluid level alarm. system designed specifically for lift pump chambers, sump pumps, Model: 101HW (High Level Alarm) N.O. holding tank sewage systems, and non -potable 101 LW (Low Level Alarm) N.C. water systems. Waterproof cable splice kit included. f Voltage: Primary 120V. 60 Hz. Secondary 12V.60 Description: The sensor float is lowered into the Hz. tank and secured at the desired level. When the fluid level rises (Model 101 HW) or lowers (Model Watts: 5 Watt Alarm Condition 101 LW) the weighted sensor float tips and ac- Alarm tivates a loud horn in the alarm panel. In addition, Panel: NEMA 1 6 in: x 4 in. x 2.5 in. metal a red, solid-state warning light will also be ac- enclosure with line cord or electrical tivated. The horn can be turned off, but the warning knock out for direct wire. light will remain on until the condition is remedied. Float: 3.18 in. dia. x 3.875 in. long. Features: This Tank Alert system is economical Mercury switch and cord are encap- sulated in impact resistant, noncor- and easy to install. The thick-walled ABS plastic rosive ABS plastic with internal float is non -corrosive and encapsulates an omni- stabilizing weight. directional mercury switch. The float switch For use in liquids up to 150°F. operates on low voltage and is isolated from the 101HW N.O. Switch 12 ft. Float Cable. power line to reduce shock hazards. (High Level) 10ILW N.C. Switch 12 ft. Float Cable. ( Low Level) / SubmersbleHhstnWi Pump Association SWO This product has been carefully designed and manufactured using only materials of the highest quality. S. J. ELECTRO SYSTEMS, INC. cares about the CONSUMER and stands behind this product with a Two -Year I Limited Warranty. mammon S. J. ELECTRO SYSTEMS, INC., Rt. 1, Box 17, Detroit Lakes, Mn. 56501 218-847-1317 MANUFACTURER OF QUALITY LIQUID LEVEL CONTROLS 9911.1 1 AVLPA 1 IVIV vl1%I_v. I IVIVa rVl% I mIvI% MLGR 1 " IYIVLJCL. IUI nvy HIYu IUILW The TANK ALERT@ alarm system includes the following: SENSOR FLOAT — mercury float switch which hangs in the tank. ALARM PANEL — located in the building. CE KIT — to make a strong, waterproof splice c !ction. Installer must provide proper length of *two conduc- tor wire which connects the sensor float to the alarm Onel. (*When used underground, wire must be ap- proved for underground use. For example: 14-2 type UJF.) SENSOR FLOAT INSTALLATION: The sensor float operates on low voltage and is isolated f om the 120V. power line to reduce shock hazards. OTE: When installing sensor float, the cable strain relief (component of tank) must be used to secure sen- sor float on entry into tank. TO SET ALARM LEVEL: The sensor float must be suspended seven inches below desired alarm level. See figures A or B or C. Figure A ALARM PANEL INSTALLATION: Mount alarm panel inside building. Mount with screw supplied and hang on keyhole in back of alarm panel. Connect a *two conductor wire from the sensor float to the screw terminals on alarm panel. NOTE: The alarm panel plugs into a standard household 120 V.A.C. socket. DO NOT plug TANK ALERT@ into the same circuit as the sewage lift pump. If the lift pump should malfunction and blow a fuse or a circuit breaker, the alarm will not work. To check alarm panel, push test button. ALARM IEVEL Figure C C CISTERN .LOW LEVEL FLOAT APPLICATION: ALARM .— BEVEL MODEL 101 LW (refer to fig. C) Suspend low level sensor float into tank. Allow seven inches of cord below alarm level. Tank Alert will activate if float descends to alarm level. DIRECTIONS FOR UNDERGROUND SPLICE CONNECTION LIFT PUMP HIGH LEVEL FLOAT APPLICA- TION: MODEL 101HW (refer to fig. A) Suspend sensor float above pump turn -on level. If a pump failure causes a high level condition, the TANK ALERTO will activate. ALARM r `E\'E . r- __� � � � 1 — Make Wire Nut Connections 2 — Wrap Electrical Tape Around Wire Connections 3 — Slide Sleeve Over Taped Connection Figure B B SEWAGE HOLDING TANK HIGH LEVEL FLOAT " APPLICATION: MODEL 101HW (refer to fig. B) Suspend sensor float into tank seven inches below alarm level. Tank Alert will activate if float ascends to alarm level. 4 - Heat Sleeve With Stick Match or Torch Check your installation by tipping the float manually. The alarm panel should indicate an alarm condition. S. J. ELECTRO SYSTEMS, INC. cannot be responsible for damages caused by the faulty or negligent installa- tion of this device. If you feel that you may encounter problems in installing this device, we respectfully sug- nPQf vnii ennane the enr"irne of ...,........+....+ ..I.. —I--.. __ __-__.... .