Loading...
HomeMy WebLinkAboutWQ0042263_Application (FTSE)_20210125DocuSign Envelope ID: CE5FD9F0-F449-4078-88BB-FCA5EBD69D7E State of North Carolina Department of Environmental Quality nUIRDivision of Water Resources Application Number:W � T (to be completed by DWR) RECEIVED/NCDEQ/D WR All items must be completed or the application will be returned JAN 2 5 2021 I. APPLICANT INFORMATION: WOROS 1. Applicant's name: WTH Times, LLC (company, municipality, HOA, utility, etc. MOORESVILLE REGIONAL OFFICE 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name: David Boyd per 15A NCAC 02T .0106(b) Title: Registered Agent/Managing Member 4. Applicant's mailing address: P.O. Box 795 City: Lincolmon State: NC Zip: 28093- 5. Applicant's contact information: Phone number: 704 201-3898 Email Address: david@timesoil.com H. PROJECT INFORMATION: 1. Project name: Moores Chapel Road 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Pemut/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Mecklenburg 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.274° Longitude:-80.969' 5. Parcel ID (if applicable): 05549114 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Josh Butler License Number: 048418 Firm: Gateway Design Group, PLLC Mailing address: 15126 Castlebridge Lane City: Matthews State: NC Zip: 28104- Phone number: (910) 840-2661 Email Address: iosh@gatewaydesigngroup.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek Permit Number: NC0024970 NC0024945 NCO024937 Owner Name: Charlotte Water V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than 'vVWTF): 1. Permit Number(s): WQunkno,,vn Downstream (Receiving) Sewer Size: 8" inch System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): Charlotte Water FORM: FTA 04-16 Page 1 of 5 DocuSign Envelope ID: CE5FD9F0-F449-4078-88BB-FCA5EBD69D7E VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ❑N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ® Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater : % Domestic/Commercial 100 % Commercial % Industrial (See 15A NCAC 02T .0103(20)) 1Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 02T ,0114(f)? ❑ Yes ❑ No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 021,0114(1)) Daily Design Flow a,b No. of Units Flow Convenience store 250 gal/plumbing fixture 9 2,250 GPD Car wash 1,200 gal/car wash 1 1,200 GPD Resturant 40 gal/seat 60 2,400 GPD gal/ GPD gal/ GPD gal/ GPD Total 5,580 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(�2 for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 5,580 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 DocuSign Envelope ID: CE5FD9F0-F449-4078-88BB-FCA5EBD69D7E VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 352.2 PVC 8" 125.3 DIP ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: PS-1 2. Approximate Coordinates (Decimal Degrees): Latitude: 35.2740 Longitude:-80.969' 3. Design flow of the pump station:.007 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 14 gallons per minute at 12 feet total dynamic head (TDR 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 1.25 157 PVC 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B). ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ® Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) [oil ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 DocuSign Envelope ID: CE5FD9F0-F449-4078-88BB-FCA5EBD69D7E LY. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(D & (g) ® Yes ❑ No ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(fl cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(fl or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ® N/A ➢ Seethe Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ® N/A ➢ This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Natiomvide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, seNver contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ❑ No ® N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 DocuSign Envelope ID: CE5FD9F0-F449-4078-88BB-FCA5EBD69D7E X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents 2. Professional Engineer's Certification: DocuSigned by: attest that this application for (Professional Engine 3Cs nagbZgEylic t* Item I11.1.) T644 has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 p violation. North Carolina Professional Engineer's seal, signature, and date ��.•"""CA �N RO''', SEAL 04841 IL -"`,,,",/y' aA�SO o" Applicant's Certification per 15A NCAC 02T .0106(b): (Signature Authority's name & title Application Item 1.3.) for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: /I� Date: FORM: FTA 04-16 Page 5 of 5 GATEWAY i v it 2 6 kCasd bri l'oe 1-aid , Matthew "L' 28104 J g4 -266f DESIGN joshjostifgate,vaydesigitgrotip.coiiiRECEIVED/NCDEQ/DWR R i E&I D/NCDEQ/C JAN ` � 2021 JAN 1 021 January11, 2021 RO NIOORESVILLE REGIONAL (OFFICE WQEGI ROS Mooresville Regional Office IVI®ORESVILLE REGIONAL Water Quality Section WR 610 E. Center Avenue, #301 RECEIVE®/NCDEQ/D Mooresville, NC 28115 ,1AN 2 5 2021 Project: Moores Chapel Road Project Location: Mecklenburg County, North Carolina WOROS MOORESVILLE REGIONAL OFFICE Dear Sir or Madam, On behalf of WTH Times, LLC, please find attached the following: 1. One original and one copy of the Sewer System Extension Applications (FTA-04-16) 2. Cover letter 3. Application fee of $48o payable to North Carolina Department of Environmental Quality (NCDEQ) (under separate cover) 4. 8.5 x 11— USGS topographic map/Street level map 5. Flow Tracking Form (FTSE 10-18) 6. Proof of business entity This project involves the construction of gravity sewer and low pressure force main for a commercial site. Please contact me with any questions/comments. Sincerely, Josh Butler, P.E. President / Owner State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEtNI EXTEtNSION\�VPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUlIENTATION Application Number: {to be completed by DtWtt) AIt items must be completed or the application evil) ate returned I. APPLICANT INFORMATION: 1. Applicant's name: AN'TH Times. LLC (company, III till jet pal ity, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership El Federal ❑ State/County ❑ kitmicipal 3. Signature authority's name: Dean Brown per 15A NCAC 02T .0106 Title: Vice President 4. Applicant's mailing address: P.O. Box 795 City: Lincolnton State: NC Zip: 28093- 5. Applicant's contact information: Phone number: (70=1} 740-9848 Email Address: dean c timesoil.cont I1. PROJECT INFORMATION: MOORESVILLE ❑ Privately-MYR,4kC1R(WQfq/DWR ❑ Other JA>J` MOORESVILLE REGIONA OFFICE iRECENED/NCOEQ/OWR j o 2 5 20 W®ROS ILA®ORESVILLE REGIONAL OFFICE I . Project name: Moores Chapel Road 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: NN'Q00 and issued date: Ifrrew construction but part of master plan, provide the existirg permit number: N1'Q00__ 3. County where project is located: NfecklenbUg 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.274` Longitude:-80.969 5. Parcel ID (if applicable): 05549114 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Josh Butler License Number: 048418 Firm: Gateway Design Group• PLLC Mailing address; 15126 Castlebridt­�e Lane City: Matthews State: NC Zip: 28104 Phone number: ( 10) 840-2661• Email Address:jagj@gajg«atidesi�nwroui>.com IV. WASTEWATER TREATMENT FACILITY (NNAVTF) INFORMATION: 1. Facility Name: McAlpine Creek•�reek. Straar Creeh Permit Number: NIC0024970. NC0024945. NC0024937 0\\-jiei- Name: Charlotte- Water V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than \N' WTF): 1. Permit Number(s): )YQuuknM Downstream (Receiving) Seaver Size: 3" inch System amide Collectiott.Sysietat Permit Number s,fif app licable : AVQCS,-- Owrter Name(s): Charlotte Water FORM: FTA 04-16 Page I of N'I. GENERAL REQUIREMENTS 1. If the Applicant is aPrivately-Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ON/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORii4: DEVV been attached? ❑ Yes [:]No ®N/A 3. If the Applicant is a 1-lame/Prate Owners' Association, lias ail Operational Agreement {FORiyi: t-IOA} becn attacliecl? ❑ Yes ❑No ❑N/A 4. Origin of wastewater (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical /dental / veterinary facilities ❑ Swimming Pool /Clubhouse [] Food and drink facilities ❑ Church ❑ Swinunin; Pool/Filter Backwash Z Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: % Domestic/Commercial 100 % Commercial % hldustrial See 15A NCAC 02T .0103(20 ) Is there a Pretreatment Program in effect? Cl Yes [] No 6. Has a flow reduction been approved under 15A NCAC 02T�.0I 1,41 ❑ Yes ® No �> If �•es, r)rovide a conv of float• reduction a ) royal Metter 7. Sununarize wastewater generated by project: Establishment Type (see 02T.0I I4 ) Convenience store Daily Design Flog a,n 250 gal/plumbing fixture No. of Units 9 Flow 2,250 GPD Car wash 1,200 gal/car wash 1 1,200 GPD Resturant 40 gal/seat 60 2,400 GPD gal/ GPD wal/ GPD gal/ lotca/ GPD 5,580 GPD a See 15, NCAC 02T .0114(b} {d} {e}{ 1 } and {e}{2} for caveats to tvaste�yater design floe rates (i.e., minimum flow per dwelling; proposed unknown non residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Water -way to be used as vacation rentals as defined in G.S. 42A-4 . b Per 15A NCAC 02T .01 14(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01 141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. \\'astewater generated by project: 5.580 GPD (per 15A NCAC 02T .01 Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of VI 1. GRAVITI' SEiVER DESIGN CRITERIA (If Applicable) - 02T.0305 & MDC Gravity Severs): 1. Stinunarizegravity sewerto be permitted: Size (incites) 8" 8" Length (feet) 352.2 125.3 Material PVC DIP Section It & III of the NIDC for Permitting of Gravity Sewers contains infomration related to design criteria Section III contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet ntininttun slope requirement is not allowed and a violation of the i41DC VI11. P U A I P STATION DESIGN CRITERIA (If Applicable)—.02T .0305 & DC � nt StatiastsfEaree �� €ins . COMPLETE FOR EACH PUrNIP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: PS-1 2. Approximate Coordinates (Decimal Degrees): Latitude: 35.274' Longitude:-80.969`' 3. Design flow of the pump station:.007 millions gallons per (lay (firm capacity) 4. Operational point(s) of the pump(s): 14 gallons per minute at 12 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 1.25 157 PVC 6. Power reliability in accordance with 15A NCAC _02T .0305 hKlj. ❑ Standby power source or pump With automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B), Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per clay I IILlst be permanent to facility Or if the pump station has an average (laity flog less than 15,000 gallons per day: ❑X Portable power source with manual activation,quick-connection receptacle and telemetry - I5A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) ZD and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or plump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 I1. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the projectcomply with all separations found in,15A NCAC 02T .0305 f)9, ® Yes ❑ No I5A NCAC 02T.0305 f contains mininuun separations that shall be 7rovided for sewers stems: Setback Parameter Se aration Required Storm sewers and other utilities not listed below (vertical) 24 inches NVater mains (vertical -water over sewer including in benched trenches 18 inches Water mains (horizontal) 10 feet Reclaimed slater lines vertical - rec(aitned over sewer) 18 inclies Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet "Any private or publie watersupply source, including any wells, tt'S-1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water 100 feet "Waters classified WS (except NVS-I or 4t'S-V), B, SA, OR\N', HQW, or S13 from normal hi==h water (or tide elevation and wetlands (see item I�.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface tlrainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainages stems and interce for drains 5 feet Any swin milia pools 10 feet Final earth Qrade (vertical) 36 inches > 15A NCAC 02T.0305(��contains alternatives where separations in 02T.0305(fj cannot be achieved. "Stream classifications can be identified using the Division's NC Surface Water Classifications webae O If noncompliance witli 02T.0305(f} oMIA see Section Y of this application 2. Does the project comply with separation requirements for Netland s? (50 feet of separation) []Yes ❑ N'o ®N/A );, See the Division's draft separation requirements for situations where separation cannot be meet r No variance is required if the alternative design criteria specified is utilized in design and construction > As built documents should reference the location of areas effected 3. Does the project comply with setbacks fbund in (lie river basin rules per 15A NCAC 0213.0200? ❑ N'es ❑ No ®N/A This would include Trout Buffered Streanns per 15A NNC5_2B.0202 4. Does the project require coveraget'authorization under 404 Nationwide or ❑ Yes Z No individual permits or 401 Water Quality Certifications? > Information can be obtained from the 401 &Buffer Permittine Branch 5. Does project comply with 15A NCAC 02T.010- c 6' (additional permits/certifications)? ® Yes ❑ 1o Per 15A NCAC 02T.0105 U a directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per I5A NCAC 02T.0402 "high -priority sextet" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer Positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. [] Yes ❑ No [A N/A > If yes, include an attachment with details fior each line, including type (aerial line, size, material, and location). Iligh priority lines shall be inspected by the permittee or its representative nt least once every six-nnonths and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual Systenn-kVide Collection permit. FORA: FTA 04-16 Page 4 of 5 S. CERTIFICATIONS: 1. Does the submitted system comply with ,ISA NCAC 02T. the Minimum Design Criteria fbr the Permittiut of Puma Stations and Force Mains (latest version), and the Gfiavr v Sewer Minim Design _Criteria {latest version) as applicable? m Yes ® No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-I4) and supportingdocuments for review. �rova[ of the re nest is re aired prior to submittal of tl►e [ ast Track r4 tlication and sun Cortina documents. 2. Professional Engineer's Certification: I, _ attest that this application for (Professional Engineer's name from Application Item 11I.1.) has been reviewed by me and is aceurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10,000, as well as civil penalties up to $25,000 Per violation. Milli Carolina Professional Engineer's seal, signature, and date: Applicant's Certification per 15A NCAC 02T .0106(b): (Signature Autlibrity's name c4 title Isom Application Item I.3.) I that this application for, has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and!or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE In accordance with General Statutes 143-21.5.6A and 143-215.6B— any person who knowingly makes any false statement, representation, or certification in any application package be guilty of Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to S25,000 per violation. Signature:Dater �� — �-� �—AIM14ak_ - - - - --- — — - - - -- � - _ F ---- FORM: FTA 0-1-16 Page 5 of 5 State of o_ Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: WTH Times, LLC Project Name for which flow is being requested: Moores Chapel Road (Store) More than one FTSE may be rerinired for it single project if the owner of the WWTP is not responsiblefor tall pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek b. WWTP Facility Permit #: NC0024970, NC0024945, NCO024937 All flows are in MGD c. WWTP facility's permitted flow 99.00 d. Estimated obligated flow not yet tributary to the WWTP 10.377 e. WWTP facility's actual avg. flow 73.817 f. Total flow for this specific request 0.00585 g. Total actual and obligated flows to the facility 84.194 h. Percent of permitted flow used 85.0% IL Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)-(B+C) (F)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, (Firm l p fl, Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** Paw Creek 11.4 4.56 6.612 0.867 7.479 -2.919 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Rhyne Road Downstream Permit Number: Unknown Page I of 6 (,,l.SE i 0-- 18 III. Certification Statement: I Keri Cantrell certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data, This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. KA., 9/10/2020 Signing Official Signature Chief Engineer Title ofSigning Of Date Page 2 of 6 F I'S F 10-18 Submit a planning assessment addendum for each pump station listed in Section I1 where Available Capacity is < 4. Pump Station (Name or Number): Given that: a. The proportion and amount of Obligated, Not Yet Tributary Daily Flow (C) accounts for 11.6 % and 0.867 MGD of the Available Capacity (E) in Pump Station Paw Creek ; and that b. The rate of activation of this obligated, not yet tributary capacity is currently approximately 0.867 MGD per year; and that c. A funded Capital Project that will provide the required planned capacity, namely Paw Creek Force Main Replacement is in design or under construction with planned completion in Paw Creek Force Main - 2020 ; and/or d. The following applies: Charlotte Water's Community Investment Plan has allocated funds for improvements to the Paw Creek force main and a five -million gallon EQ basin at Long Creek Pump Station. Long Creek and Paw Creek pump stations operate as a system using SCADA data to determine the rate of flow delivered from the upstream pump station, Long Creek, to Paw Creek the downstream facility. Long Creek pump station has the ability to transfer flows to flow equalization tanks during peak flow events and then meter out flow to Paw Creek as flow conditions allow. In addition, the basins for both stations are large and result in a daily peaking factor of 2.06 at Paw Creek Pump Station, which allows the stations to operate safely at flows greater than 40% of the firm pumping capacity. Therefore: Given reasonably expected conditions and planning information, there is sufficient justification to allow this flow to be permitted, without a significant likelihood of over -allocating capacity in the system infrastructure. I understand that this does not relieve the collection system owner from complying with G.S. 143-215.67(a) which prohibits the introduction of any waste in excess of the capacity of the waste disposal system. Signing Off cial Signature Date Page 3 of 6 -File an Annual Report/Amend an Annual Report - Upload a PDF Filing - Order a Document Online - Add Entity to My Email Notification List 'View Filings - Print a Pre -Populated Annual Report form -Prim an Amended a Annual Report form Limited LiabiLity Company Legal Rame WTW Tittes, L =1 Mc, =71 Sosid: 0675131 Status: Current -Active Q Date Formed: 5/13/2003 Citizenship: Domestic Annut*j,L R ort Due Date: Ayri 11 5th Registered Agent: Boyd, David M, Principal Office 1500 E Main St Lincointon, NC 28092 Manager David Boyd Lincolnton NC 28092 Reg Off ice 1500 E. Main SI mmins MaiLing PO Box 795 Lincointon, NC 28093 Manager Sweet Treat Holdings, LLC 1500 East Main Street Reg Mailing PO Box 795 'Lincointon, NC 28093 For 1XIIIIIIIET M-141 January 5, 2021 Prepared for: ill Faq ff I me =- LincoInton, NC A C .4 0 "o SEAL 048 e 1 N F- "N"42A B U1 4644 a A ab a a " �01 Gateway Design Group, PLLC P-2147 Cell: (gio) 840-2661 Mailing Address: 15126 Castlebridge Lane Matthews, NC 28104 Moores Chapel Road is a new commercial project. The project consists of a restaurant, convenience store, and car wash. Sewage will leave the site via private grinder pump station and foreemain emptying into private manhole. Gateway Design Group, PLLC Gateway Design Group, PLLC Project Name: monmsCfhapo| Project No. zno�ooz Date: 1/6/202z CelcEy: APYo No. of Services � Daily Flow sLs0gyd Daily Flow, OddM 41gpm OMthoAdditional Flow, QdC2 CLVgpm Total Daily Flow, QdUf 41Opm Peak Flow, Qp 102gpm Qp=Qddfxx.5 Size ofForce Main, d z. 2ginches Velocity, v1(based onpeak flow) 2.7ft/soo v1=0.409Qp/d^2 Trial Pump Flow, Qudj 112gpm Velocity, v2(based onpump flow) 3.1 ft/soo v2=0.409Oudj/d^2 D|a.nfWet Well, D 15 D TRIAL CYCLE TIME 20min 2Omin. pump down volume, V 537ga| V=VJddf(1-(Qddf/0mdj). t = 20 20 min. pump down volume, V 72 of V=V°0.1837 uOmin. pump down height, k OJh h=4V4314DA g Wet Well Elevations Proposed Top ofWet VVoUElew. M Ground Elev. +12^ 8GInv. |n 748.8 ft Gravity Line Invert = Top minus 44.3" High Water Alarm 744.4 ft Alarm =8''Above Pump On Pump 1On 743.8 ft Pump On4^Above Pump Off Pump Off 743A ft Pump Off =18.84^from Bottom u Bottom M Required Depth ofWet Well 10.2ft Top E|o,,BouomElev. PUMP STATION DESIGN SYSTEM CURVES Moores Chapel Job Name llvlor, " Ci nel 2020-002 Job No. 2020 002 1/6/2021 Date 1 /6/ 10 Starting Pump Elevation, Z1 74 Force Main Discharge Elevation, Z2 753 53 3 a' High Point Elevation, Z2max :; 5^ STATIC HEAD 9 9 9 9 9 Length of Force Main (Feet) 2 _. _ 2; Diameter of Force Main (Ft), D 1.25" PVG Hazen Williams C for Force Main, C i20 �20 Discharge (GPM), Q 6 8 10 12 cn vvuuania � uauvn - nv woa Hp= L ((10.44Q185)/((C185)(D4.e7))) 0 1 1 1 2 Hp = Total Piping System Head Loss 9 10 10 10 11 Minor Losses K value Minor Losses (ft) 11.25d Bends ___ 0.0 0.0 0.0 0.1 0.1 22.5d Bends 0.0 0.0 0.0 0.0 0.0 45d Bends 0.0 0.0 0.0 0.0 0.0 90d Bends 0.0 0.0 0.0 0.0 0.0 No. Check Valves 0.2 0.3 0.5 0.8 1.0 Entrance/Exit 3 0.1 0.1 0.2 0.3 0.4 No. Gate Valves _.. 0.0 0.0 0.0 0.0 0.0 No. Tees / ARV _.., 0.0 0.0 0.0 0.0 0.0 hl = Total Minor Losses (Feet) 0.3 0.5 0.8 1.1 1.5 TDH (feet) = H +hl(minor) 10 10 11 11 12 Pump Curve (TDH) 230 170 120 70 20 Check Pump Cycle 7 gal (from Wet Well Sizing Calc) Volume Fill Time _2 min t=V/Qddf Pump Time min t2=V/Qpump Total 17.7 min 3 cycles per hour, OK System pump Curve 0 2 4 6 8 10 12 14 16 240 j Gateway Design Group, PLLC EJONE SPO PUMP PERFORMANCE CURVE GRINDER PUMP, lHP, 1725 RPM 10o 230 95 \ 220 \ \ 210 90 \ 200 85 190 80 LOW PRESSURE SYSTEM DESIGN PRESSURE 180 75 170 CONSULT FJPSI FOR INTERM USE ABOVE70 OR 185 FE 160 65 150 60 140 130 w 55 120 cn 50 110 45 0 n CD 100 Q z 40 N 90 w o 1-135 0 80 w `C 30 w 70 `� � Q n- z z 25 60 Q Q w 50 = 0 20 u 40 Q 15 >- 30 C' 10 20 1- 0 5 10 0 0 -5 -10 -20 - 10 -30 -15 -40 -20 -50 -25 -60 I I I I I I I I I I 0 2 4 6 8 10 12 14 16 18 DISCHARGE (Q), GPM ESD 08-0022 REV. 2, 6/08