Lauren,
Here is my comment about the design of the LS-VFS.
Thanks,
Annette
Annette M. Lucas, PE
Environmental Engineer
NCDENR DWQ Wetlands and Stormwater Branch
1650 Mail Service Center, Raleigh, NC 27699-1650 (Mail)
512 N. Salisbury St, Raleigh, NC 27604 1 9th Floor (L()cation &, Parcels)
Phone: (919) 807-6381 1 Fax: (919) 807-6494 1 Email: Anuettc Luc?i?d'nt ti??lt.gol'
--- ---- -
Website: http://portal.ncdenr.org/web/wq/swp/ws/401
`,A Before printing this email, please consider your budget and the environment.
E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to
third parties.
11-0777 Batts Farm
AML comments
September 20, 2011
1. Per Table 8-1 in the BMP Manual, a level spreader-engineered filter strip should be designed to
handle the 10-year storm discharge up to 10 cfs. Therefore, the level spreader should be
enlarged to a minimum of 79 feet in length so that it will be capable of treating the peak
discharge from the wet detention pond during the 10-year storm (7.9 cfs).