Loading...
HomeMy WebLinkAboutSW5190703_Form_(Supp.EZ)_20200408DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so, number of drainage areas/SCMs 1 3 Is all/part of this project subject to previous rule versions? No FORMS LOADED Entire Site 1 4 Type of SCM Sand Filter 5 Total BUA in project (sq ft) 48152 sf 22819 sf 6 New BUA on subdivided lots (subject to permitting) (sq ft) 7 New BUA outside of subdivided lots (subject to permitting) (sf) 4810 sf 8 Offsite - total area (sq ft) 6789 sf 9 Offsite BUA (sq ft) 3491 sf 10 Breakdown of new BUA outside subdivided lots: - Parking (sq ft) - Sidewalk (sq ft) - Roof (sq ft) - Roadway (sq ft) - Future (sq ft) - Other, please specify in the comment box below (sq ft) 4810 sf 11 New infiltrating permeable pavement on subdivided lots (sq ft) 12 New infiltrating permeable pavement outside of subdivided lots (sq ft) 13 Exisitng BUA that will remain (not subject to permitting) (sq ft) 43342 sf 22819 sf 14 Existing BUA that is already permitted (sq ft) 15 Existing BUA that will be removed (sq ft) 1374 sf 16 Percent BUA 42% 41% 17 Design storm (inches) 1 in 1 in 18 Design volume of SCM (cu ft) 1500 cf 1500 cf 19 Calculation method for design volume Simple Method 20 DRAINAGE AREA INFORMATION ADDITIONAL INFORMATION Other in the Enitre Site Column refers to the net increase in impervious on site. Drainage area 1 corresponds to the area being routed to the sand filter. Please use this space to provide any additional information about the drainage area(s): SAND FILTER 1 Drainage area number 1 2 Design volume of SCM (cu ft) 1500 cf 3 Is the SCM sized to treat the SW from all surfaces at build-out?Yes 4 Is the SCM located away from contaminated soils? Yes 5 What are the side slopes of the SCM (H:V)? :1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No 7 Are the inlets, outlets, and receiving stream protected from erosion (10- year storm)? Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes 9 What is the method for dewatering the SCM for maintenance? Pump (preferred) 10 If applicable, will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC (8)? Yes 12 Does the drainage easement comply with General MDC (9)? Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? No 14 Is there an O&M Agreement that complies with General MDC (11)? Yes 15 Is there an O&M Plan that complies with General MDC (12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an NC licensed professional? Yes 18 SHWT elevation (fmsl) 345.64 19 Type of sand filter (open or closed) Closed 20 If closed, will the filter will be pre-cast or pour-in-place? Pre Cast 21 If closed, top of grate elevation (fmsl)350.45, 348.43, 347.35 22 Is this sand filter designed to attenuate peak flows? Yes 23 Volume that can be retained in the sediment chamber (cubic feet)750 cf 24 Will there be a permanent pool in the sediment chamber? Yes 25 Bottom of the sediment chamber (fmsl)337.00 26 Area of the sediment chamber (square feet)750 sf 27 Physical depth of the sediment chamber (inches)72 in 28 Ponding depth in the sediment chamber, above any permanent pool (inches) 12 in 29 Elevation of top of weir between chambers (fmsl) 339.5 30 Volume that can be retained in the sand chamber (cubic feet)750 cf 31 Bottom of the sand chamber (fmsl)337.00 32 Area of the sand chamber (square feet)750 sf 33 Physical depth of the sand chamber (inches)72 in 34 Ponding depth in the sand chamber, above any permanent pool (inches) 12 in 35 Elevation of the bypass device (fmsl) 340.5 36 Type of bypass device 6" DIP 37 Mechanism for distributing flow over the sand surface Weir 38 Sand specification for sand chamber ASTM C-33 39 Depth above underdrain pipe (inches) 18 in 40 Will the media be maintained to drain at least two inches per hour at the sand surface? Yes 41 Is at least one clean-out pipe provided at the low point of each underdrain line? Yes 42 Will clean-out pipes be capped? Yes 43 Please use this space to provide any additional information about the Sand Filter(s): The Sand Filter is entirely closed. The top of grate elevations listed are the top of access hatch to get into the sand filter for maintenace. SAND FILTER MDC FROM 02H .1056 GENERAL MDC FROM 02H .1050 Sand Chamber Sediment Chamber ADDITIONAL INFORMATION Sand Filter 1 8:50 AM 3/31/2020