HomeMy WebLinkAboutWQ0021603_Permit (Issuance)_20020726 State of North Carolina Department of Environment and Natural Resources Asheville Regionalbffice Michael F. Easley, Governor N C D EN R William G.Ross,Jr., Secretary Alan W. Mraely P.E.,Director NORTH CAROUNA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Division of Water Quality WATER QUALITY SECTION July 26, 2002 Mr. Ezra Allman, Director of Utilities City of Hendersonville Post Office Box 1760 Hendersonville, North Carolina 28793-1760 SUBJECT: Permit No. WQ0021603 City of Hendersonville Carriage Park Section 9 Wastewater Collection System Extension A Henderson County Dear Mr. Allman: F In accordance with your application,received on July 22, 2002, please find attached Permit No. W00021603 for the construction and operation of the subject wastewater collection system extension. This Permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. This cover letter shall be considered a part of this permit and is therefore incorporated therein by reference. Please pay particular attention to condition three (3) of the permit which requires that the wastewater collection facilities be properly operated and maintained in accordance with 15A NCAC 2H .0227 or any individual system-wide collection system permit issued to the Permittee. Permitting of this project does not constitute acceptance of any part of the project that does not meet 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; and the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains adopted June 1,2000 as applicable, unless specifically mentioned herein. Division approval is based on acceptance of the certification provided by a North Carolina-licensed Professional Engineer in the application. It shall be the Permittee's responsibility to ensure that the as-constructed project meets the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute 143-215.6A through 143-215.6C, construction of additional or replacement wastewater collection facilities, and/or referral of the North Carolina-Licensed Professional Engineer to the licensing board. 1 • x Ezra Allman r July 26, 2002 Page Two In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the City of Hendersonville for the construction and operation of approximately 1,227 linear feet of 8 inch PVC gravity sewer and 1,519 linear feet of 8 inch ductile iron gravity sewer and the discharge of approximately 9,360 gpd of wastewater into the City of Hendersonville's existing sewerage system, pursuant to the application received on July 22, 2002 and in conformity with 15A NCAC 2H .0200; the Division's Gravity Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains adopted June 1„2000 as applicable; and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. The sewage and wastewater collected by this system shall be treated in the City of Hendersonville's wastewater treatment facility (NPDES Permit No. NC0025534) prior to being discharged into Mud Creek in the French Broad River Basin. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit: This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional information concerning this matter, please contact Mr. Roy Davis at 828/251-6208. Sincerely, Alan W. Klimek, A. E. Enclosure xc: Henderson County Health Department Non-Discharge Permitting Unit Patterson & Patterson Roy Davis 2 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION SYSTEM EXTENSION PERMIT CITY of HENDERSONVILLE CARRIAGE PARK SECTION 9 PERMIT NUMBER W00021603 This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the wastewater collection facilities are constructed in accordance with the conditions of this permit: 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials unless specifically mentioned herein. 2. This permit shall be effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The wastewater collection facilities shall be properly maintained and operated at all times. The Permittee shall maintain compliance with an individual system-wide collection system permit for the operation and maintenance of these facilities as required by 15A NCAC 2H .0227. If an individual permit is not required, the following performance criteria shall be met as provided in 15A NCAC 2H .0227: a. The sewer system shall be effectively maintained and operated at all times to prevent discharge to surface waters, and any contravention of the groundwater standards in 15A NCAC 2L .0200 or the surface water standards in 15A NCAC 2B .0200. b. A map of the sewer system shall be developed prior to January 1, 2004 and shall be actively maintained. C. An operation and maintenance plan shall be developed and implemented. d. Pump stations that are not connected to a telemetry system shall be inspected every day, as defined in 15A NCAC 213 .0503(5). Pump stations that are connected to a telemetry system shall be inspected at least once per week. e. High-priority sewer lines shall be inspected at least once per every six-month period of time. 3 WQ0021603 f. A general observation of the entire sewer system shall be conducted at least once per year. g. Inspection and maintenance records shall be maintained for a period of at least three years. h. Overflows and bypasses shall be reported to the appropriate Division Regional Office in accordance with 15A NCAC 2B .0506(a), and public notice shall be provided as required by North Carolina General Statute 143-215.1C. 4. This permit shall not be transferable. In the event there is a desire for the wastewater facilities to change ownership, or there is a name change of the Permittee, a formal permit request shall be submitted to the Division accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request shall be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of these permitted facilities, a certification, a copy of the construction record drawings, as well as supporting design calculations for any pump stations permitted as part of this project shall be received from a North Carolina-licensed Professional Engineer certifying that the facilities have been installed in accordance with this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Station and Force Main adopted June 1, 2000 as applicable; and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the construction record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Engineer's Certification, one copy of the "Construction Record Drawings", and one copy of the supporting design calculations to the Non-Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the construction record drawings shall be maintained on file by the Permittee for the life of the wastewater collection facilities. 8. Failure to abide by the conditions and limitations contained in this permit; 15A NCAC 2H .0200; the Division's Gravity Sewer Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Station and Force Mains adopted June 1, 2000 as applicable; and other supporting materials may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statutes 143-215.6A through 143-215.6C. 4 WQ0021603 9. In the event that the wastewater collection facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement facilities. 10. The issuance of this permit shall not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (local, state and federal) which have jurisdiction, including but not limited to applicable river buffer rules in 15A7NCAC 2B .0200, erosion and sedimentation control requirements in 15A NCAC Ch. 4 and under the Division's General Permit NCG0100000, and any requirements pertaining to wetlands under 15A NCAC 213 .0200 and 15A NCAC 2H .0500. 11. Non-compliance Notification: The Permittee shall report by telephone to the Asheville Regional Office, telephone number 828/251-6208 as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any, process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. Permit issued this the 26t' day of July, 2002. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Alan W. li k, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0021603 5 Permit No. WQ0021603 July 26, 2002 - ENGINEERS CERTIFICATION Partial Final I, as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full timef the construction of the project, Carriage Park Section 9, City of Hendersonville. N.C., Henderson County, for the Project Name Location and County Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains adopted June 1., 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: The above Engineer's Certification shall be completed and submitted to the address below with one copy of the "Construction Record Drawings" of the wastewater collection system extension as well as supporting design calculations for any pump stations permitted as part of this project. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION NON-DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 6 07/24/02 Permit Number WQ0021603 Permit Tracking S7 Program Category Status Project Type Non-discharge In review New Project Permit Type Fast Track Version Permit Classification Gravity Sewer Extension, Pump Stations, & Individual Pressure Sewer Extensions Primary Reviewer Permit Contact Affiliation forrest.westall Permitted Flow Facility Facility Name Major/Minor Region Carriage Park Section 9 Minor Asheville Location Address County Henderson Facility Contact Affiliation Owner Owner Name Owner Type City of Hendersonville Government - Municipal Owner Affiliation Ezra Allman P.O. Box 1760 Hendersonville NC 287931760 Dates/Events Draft Scheduled Public Orig Issue App Received Initiated Issuance Notice Issue Effective Expiration 07/22/02 Regulated Activities Requested/Received Events NULL RO staff report received RO staff report requested Additional information requested Additional information received Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin JUL 2 5 2002�1. PJATER O AUTY SEGTION �ASHFVILLE_I;CGIOtL OFFICE OFFICERS: - CITY OF HEND�ERSONVILLE °`"°°°"CIL: Fred H.Niehoff,.Jr. - BARBARA VOLK "The The City of Four.Seasons" 'Mary Jo Padgett' - - MARY Jo PADGETT Mayor Pro-Tem James L. Patrick, P.E. Chris A.Carter LONDA MURRAY City Manager- City-Engineer Tammie K.Drake , RON STEPHENS City Clerk - -LETTER OF TRANSMITTAL Mr. Kim H. Colson,P.E..Supervisor July 17, 2002 N.C.D.E.N.R.Division of Water Quality 16.17 Mail"Service Center JUL 2 5 2002 Raleigh,N.C. 27699-1617 r I, Attached;we are sending.you(TWO(2) COPIES of FAST-TRACK APPLICATION for GRAVITY SEWERS;. PUMP STATIONS, AND FORCE MAINS and the .$400 APPLICATION FEE),and (ONE COPY of a CAPACITY ACCEPTANCE LETTER) for Carriage Park Section 9—Sewer Extension. This project is being forwarded to you for your review and-approval.' Submitted By: Pv; Jr Engineering Department CITY OF HENDERSONVILLE cc: Project File JUL 2 2 P002 j - k �V(JN-DI$CHNHGE PERIJI"iTth'G 145 Fifth Avenue East P.O.Box 1670 Phone:: (828)697-3060 Hendersonville,NC 28792-4328 Hendersonville,NC 28793-1670 " Fax: (828)697-3066 e-mail:jpatrick@cityofhendersonville.org - Wwi.v.cityofhendersonville.org OFFICERS: CITY OF HENDERSONVILLE CITY COUNCIL: Fred H.Niehotf,Jr. `The Cily of Four Seasons" BARBARA VOLK Mayor Mary Jo Padgett MARY JO PADGM Mayor Pro WATER AND SEWER DEPARTMENT Chris A.Carte[er LONDA HURRAY City Manager Ezra Allman, Director Tammie K.Drake e-mail:eallman@cityofhendersonville.org RON STEPHENS City Clerk July 17, 2002 Mr.Kim H. Colson, P.E., Supervisor N.C. Department of Environment &Natural Resources Division of Water Quality —t 1617 Mail Service Center Raleigh,NC 27699-1617 � - `IUI Re: Gy r� CC101110W LETTER m� .�UL 2 5 ` 2 C *atria e Par Sec-f Sewer me xtens - r Dear Mr. Colson: This is to advise you that I have reviewed the plans and specifications prepared by Mr. R. Paul Patterson;P.E., of Patterson & Patterson,Hendersonville,N.C. for the referenced project. It is my opinion that the City of Hendersonville has the capacity to accept the additional wastewater flows that will be generated by the referenced project. The project is being submitted via Fast-Track for your review and approval. If you have any questions, feel free to contact me at (828) 697-3063. Sincerely, Ez Mlrman, DirectcrC Water and Sewer Department CITY OF HENDERSONVILLE lit cc: Project file f '=Ct!TY sEC7I N � r I JUL 2 2 2002 ;! 1140 ��-pISCHA_..-_�`___r, 318 Fourth Avenue East P.O.Box 1760 Phone:. (828)697-3063 Hendersonville,NC 28792-4428 Hendersonville,NC 28793-1760 - Fax:, (828)697-1707 e-mail:wsdept@cityofhendenonvike.org v .cityofhendersonville.org ,. , :� ,L State of North Carolina Department of Environment, Health and Natural Resources Division of Water Quality FAST-TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS,AND FORCE MAINS (Pressure sewer systems are not to be included as part of this application pac age nn 2 1I 11SAN MATHISFORMYBEPHOTOCOPIEDFOR USEAORIGRVAL RR INSTRUCTIONS: Indicate that you have included the following list of required application package•i[ems_by signing your 44ae ei,.��. initials in the space provided next to each item. Failure to submit all required items will lead to additional processiirgand,;ieview 9r the permit application A. Application Form-Submit one original and one copy of the completed and appropriately executed application form. Any changes to this forth will result in the application being returned. The Division of Water Quality(Division)will only accept application packages that have been fully completed with all applicable items addressed. You do not need Qto submit detailed plans and specifications unless you respond NO to item IV.6.and/or item IV.10. (B Attachment-Submit the completed and properly executed Form WSCA10/99 for each watershed within the project location. C. Application Fee-Submit a check in the amount of$400 made payable to:North Carolina Department of Environment and Natural Resources(NCDENR). D. Certificates of Public Convenience and Necessity-If the application is being submitted in the name of a privately- owned public utility,submit two copies of the Certificate of Public Convenience and Necessity,which demonstrates that the public utility is authorized to hold the utility franchise for the area to he served by the sewer extension. If a Certificate of Public Convenience and Necessity has not been issued,provide two copies of a letter from the NC Utilities Commission's Public Staff that states that an application for a franchise has been received,that the service area is contiguous to art existing franchised area,and/or that franchise approval is expected. E. Operational Agreements-Submit one original and two copies of a properly executed operational agreement if the sewer extension will be serving residential or commercial lots(e.g.,houses,condominiums,townhomes,outparcels, etc.)that will be owned by a homeowners'association or developer. If the applicant is a homeowners'association,use Form HOA 10/99. If the applicant is a developer,use Form DEV 10199. F. Flow Acceptance Letters-If the owner of the downstream Sewer and/or W WTF is different from the applicant, submit two copies of a flow acceptance letter from the owner of the downstream sewers and W WTF. Flow acceptance letters must contain the following minimum information:applicant and project name,amount of flow accepted,and name and permit number of the receiving sewers/W WTF.The flow acceptance must not expire prior to permit issuance and must he dated less than a year prior to the application date.Intergovernmental agreements or other contracts will not he accepted in lieu of a project-specific now acceptance letter. THE COMPLETED APPLICATION PACKAGE,INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS,SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY NON-DISCHARGE PERMITTING UNIT By U.S.Postal Service: By Courier/Special Delivery: 1617 MAIL SERVICE CENTER 512 NORTH SALISBURY STREET,SUITE 1219 RALEIGH,NORTH CAROLINA 27699-1617 RALEIGH,NORTH CAROLINA 27604 TELEPHONE NUMBER:(919)733-5083 FACSIMILE NUMBER:(919)715-6048 'f — OUAI!TY S For more injormafim4 visit our web site at:h2o.ennsrare.nc.a/mi . ---`- ECT zooz ) FORM: FTA 06/00 Page I of 5 NON-D rSCHARGE rERr,CITTrN.G ^ Application Number: V" b b Zi i&to be completed by DWQ) L GENERAL INFORMATION: 1. Applicant's name(name of the municipality,corporation.individual,etc.): City of Hendersonville 2. Owners or signing official's name and title(15A NCAC 2H.0206(b)): Ezra Allman-Director 3. Name and complete address of applicant: City of Hendersonville P.O.Box 1760 City: Hendersonville State: NC Zip: 28793-1760 Telephone Number: 828 697-3063 Facsimile Number: 828 697-1707 4. Project Name(name of the subdivision,facility or establishment,etc.): Carriage Park,Section 9 Sewer Extension 5. County where project is located: Henderson 6. Fee Submitted:$ 400 (See Instruction C.) 7. Name and complete address of engineering fine: Patterson&Patterson c/o Paul Patterson-P.E.,P.O.Box 1189 City: Hendersonville State: NC Zip: 28793-1189 Telephone Number: 828 692-6629 Facsimile Number:l_ 828 692-6629 8. Name and affiliation of contact person who can answer questions about application: Paul Patterson.P.E.or Ezra Allman-Director @ City of Hendersonville F'I y3 n 11. PERMIT INFORMATION: ? JUL 2 5 2002 1. Project is: X new; modification. - 2. If this application is being submitted as a result of a modification to an existing permit,provide:,- existing permit number and the issue date_ 3. Applicant is X public _private. If private,units(lots,townhomes,etc.)are:_ leased(Skip to item III); :_ sold If sold,facilities owned by a: public utility(See Instruction D.); homeowners'association/developer(See Instruction E.) in. INFORMATION ON WASTEWATER: 1. Please provide a one-or two-word description specifying the origin of the wastewater(school, subdivision,hospital,commercial facility,industry,apartments,condominiums,etc.): residential subdivision 2. Volume of wastewater generated by this project: gallons per day. 3. Explanation of how wastewater flow was determined(15r A�NCCAA�C�2H.0219(l)): 26 homes @ 3 bedrooms(a� 120 gallons per day—9,360 GAD 4. Nature of Wastewater. 100 %Domestic/Commercial; %Industrial — _%Other(specify) 4t;A:•c;; ;_,,,� ".e G - —..._ -. - +UT'r F`crrrrTd � JUL 2 2 2002 , FORM: FTA 06/00 Page 2 of 5 IgONr-DISCHARRCC p�Fh;li inG 5. If wastewater is industrial in nature: a. Level of pretreatment has been provided to ensure protection of the receiving collection system and wastewater treatment facility: N/A b If a pretreatment permit is required,has one been issued? N/A Yes No. If yes,please attach a copy of the pretreatment permit. If no,provide date application was submitted IV. DESIGN INFORMATION: 1. Brief project description: Proposed subdivision of 26 lots/units with gravity sewer to an existing sewer manhole. ��- 2. Owner and name of wastewater treatment facility(W WTF)receiving wastewater(See Instruction F.): City of Hendersonville W WTF 3. WWTF permit number(NC00*****or WQ00*****): NCO025534 4. List the owner(s)of any intermediate sewers if different from applicant or owner of W WTF(See Instruction F.) N/A 5. Summary of GRAVITY SEWER to be permitted: Diameter Length (inches) (linear feet) "SDI235 PYG - 6. Does the subject gravity sewer collection system comply with the most recent version of the Gravity Sewer Minimum Design Criteria and 15A NCAC 2H.0200? X Yes No. If no,please identify criteria and explain 7. Summary of PUMP STATIONS to be permitted: No. or Design Flow Pump Operational Pints Reliability Option Name (MGD) GPM feet TDH Selected N/A FORM: FTA 06/00 Page 3 of 5 8. Summary of FORCE MAIN to be permitted: Diameter Length inches uearfeet N/A 9. List any equipment being utilized that is not specifically mentioned elsewhere in the application or as part of the Minimum Design Criteria(e.g.,telemetry,hoist,odor control equipment,mechanical bar screens,etc.): N/A 10. Do the subject pump stations and force mains comply with the minimum Design Criteria for the Fast- Tract Permitting of Pump Stations and Force Mains documents adopted June 1,2000 and 15A NCAC 2H .0200? Yes; No. if no,please identify criteria and explain: N/A NOTE: If you responded NO to item IVA and/or item IV.10. above, two (2) copies of detailed plans, specifications, supporting information, and any other materials pertaining to the identified criteria should be submitted with the completed and appropriately executed application form. V ATFRAL/7Y Sc_ JUL 2 2 @02 FORM: FTA 06/00 Page 4 of 5 NON —oe P ER!✓.•1�i fNr V. ,CERTIFICATIONS Professional Engineer's Certification: I, Robert Paul Patterson attest that this application for Carriage Park,Section 9-Sewer Extension _ has been reviewed by me and is accurate,complete and consistent with the information supplied in the engineering plans,calculations,and all other supporting documentation to the best of my knowledge.I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations,Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996,and the Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains adopted June 1,2000. Although certain portions of this submittal package may have been developed by other professionals,inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design.Note:In accordance with NC General Statutes 143-215.6A and 143-215.613,any person who knowingly makes any false statement,representation,or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed$10,000 as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's Seal,Signature,and Date: 14 CA/�O �O _0 023131 $Z Applicant's Certification: I, Ezra Allman.Director attest that this application for Carriage Park, Section 9-Sewer Extension _ has been reviewed by me and is accurate and complete to the best of my knowledge.I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included,this application package will be returned to me as incomplete.Note: In accordance with NC General Statutes 143-215.6A and 143-215.613,any person who knowingly makes any false statement,representation.or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed$10,000 as well as civil penalties up to$25,000 per violation. Signature C Z4,a Date JUL 2 5 2002 Rio,0 p,ems.UFM, 1^.'/-FR 1I4L��,' JUL 2 2 2002 f FORM: FTA 06/00 Page 5 of 5 �—---____. __ - JIJ-DISCH _ ARGE State of North Carolina Department of Environment, Health and Natural Resources Division of Water Quality FAST-TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS (Pressure sewer systems are not to be included as part of this application package) THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL INSTRUCTIONS: Indicate that you have included the following list of required application package items by signing your initials in the space provided next to each item. Failure to submit all required items will lead to additional processing and review GtJ�—i the permit application. A. Application Form-Submit one original and one copy of the completed and appropriately executed application form. Any changes to this form will result in the application being returned. The Division of Water Quality(Division)will only accept application packages that have been fully completed with all applicable items addressed. You do not need to submit detailed plans and specifications unless you respond NO to item IV.6.and/or item TV.10. B. Attachment-Submit the completed and properly executed Form W SCA10/99 for each watershed within the project n location. C. Application Fee-Submit a check in the amount of$400 made payable to:North Carolina Department of Environment and Natural Resources(NCDENR). D. Certificates of Public Convenience and Necessity-If the application is being submitted in the name of a privately- owned public utility,submit two copies ofthe Certificate of Public Convenience and Necessity,which demonstrates that the public utility is authorized to hold the utility franchise for the area to he served by the sewer extension. If a Certificate of Public Convenience and Necessity has not been issued,provide two copies of a letter from the NC Utilities Commission's Public Staff that states that an application for a franchise has been received,that the service area is contiguous to art existing franchised area,and/or that franchise approval is expected. E. Operational Agreements-Submit one original and two copies of properly executed operational agreement if the sewer extension will be serving residential or commercial lots(e.g.,houses,condominiums,townhomes,outparcels, etc.)that will be owned by a homeowners'association or developer. if the applicant is a homeowners'association,use Form HOA 10/99. If the applicant is a developer,use Form DEV 10/99. F. Flow Acceptance Letters-If the owner of the downstream Sewer and/or W WTF is different from the applicant, submit two copies of a flow acceptance letter from the owner of the downstream sewers and W WTF. Flow acceptance letters must contain the following minimum information:applicant and project name,amount of flow accepted,and name and permit number of the receiving sewers/W WTF.The flow acceptance must not expire prior to permit issuance and must he dated less than a year prior to the application date.Intergovernmental agreements or other contracts will not he accepted in lieu of a project-specific flow acceptance letter. THE COMPLETED.APPLICATION PACKAGE,INCLUDING ALL SUPPORTING'vINFORMATION AND iVI II MATERIALS,SHOULD BE SENT TO THE FOLLOWING ADDRESS:� JUL 2 5 20OZ f -� Llll, p9 NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY _ ;P:SfCTI�P! NON-DISCHARGE PERMITTING UNIT t^.h°lu l' I,'_1j:iJAl O !U I�i By U.S.Postal Service: By Courier/Special Delivery: 1617 MAIL SERVICE CENTER 512 NORTH SALISBURY STREET,SUITE 1219 RALEIGH,NORTH CAROLINA 27699-1617 RALEIGH,NORTH CAROLINA 27604 TELEPHONE NUMBER:(919)733-5083 ----... FACSIMILE NUMBER.(919)715-6048 „ -I,, •.i ' For more information,visit our web site at.,h2o.encs1a1e.nc.us/ndpu1 - --- _-- JUL 2 2 2002 FORM: FTA 06/00 Page 1 of 5 L� DISCH/1R'_F PEF' y�. 1 Application Number: b16 (to be completed by DWt) I. GENERAL INFORMATION: 1. Applicant's name(name of the municipality,corporation.individual,etc.): City of Hendersonville 2. Owners or signing official's name and title(I SA NCAC 2H.0206(b)): Ezra Allman,Director 3. Name and complete address of applicant City of Hendersonville P.O.Box 1760 City: Hendersonville State: NC Zip: 28793-1760 Telephone Number: 828 697-3063 Facsimile Number: 828 697-1707 4. Project Name(name of the subdivision,facility or establishment,etc.): Carriage Park,Section 9 Sewer Extension 5. County where project is located: Henderson 6. Fee Submitted:$ 400 (See Instruction C.) 7. Name and complete address of engineering firm: Patterson&Patterson c/o Paul Patterson P.E..P.O.Box It 89 City: Hendersonville State: NC Zip: 28793-1189 Telephone Number: 828 692-6629 Facsimile Number: L 828 692-6629 8. Name and affiliation of contact person who can answer questions about application: Paul Patterson,P.E.or Ezra Allman.Director(a City of Hendersonville H. PERMIT INFORMATION: I J, 7U1 5 Zppp D 1. Project is: X new; modification, 2. If this application is being submitted as a result of a modification to an exist d t p Tv SECTION PP g g pernii 'i r01 e existing permit number and the issue date ([GIONAL OFFIG 3. Applicant is X public _private. If private,units(lots,townhomes,etc.)are:_ leased(Skip to item III); : sold If sold,facilities owned by a: public utility(See Instruction D.); homeowners'association/developer(See Instruction E.) M. INFORMATION ON WASTEWATER: 1. Please provide a one-or two-word description specifying the origin of the wastewater(school, subdivision,hospital,commercial facility,industry,apartments,condominiums,etc.): residential subdivision 2. Volume of wastewater generated by this project: 9,360 gallons per day. 3. Explanation of how wastewater flow was determined(15A NCAC 2H.0219(1)): 26 homes n 3 bedrooms 120 gallons per day=9,360 GPD 4. Nature of Wastewater: 100 %Domestic/Commercial; %Industrial; %Other(specify) FORM: FTA 06/00 Page 2 of 5 v 5. If wastewater is industrial in nature: a. Level of pretreatment has been provided to ensure protection of the receiving collection system and wastewater treatment facility: N/A b If a pretreatment permit is required,has one been issued? N/A Yes No. If yes,please attach a copy of the pretreatment permit. If no,provide date application was submitted IV. DESIGN INFORMATION: 1. Brief project description: Proposed subdivision of 26 lots/units with gravity sewer to an existing sewer manhole. 2. Owner and name of wastewater treatment facility(W WTF)receiving wastewater(See Instruction F.): City of Hendersonville W WTF 3. W WTF permit number(NC00*****or W000*****): NCO025534 4. List the owner(s)of any intermediate sewers if different from applicant or owner of W WTF(See Instruction F.) N/A _ 5. Summary of GRAVITY SEWER to be permitted: Diameter Length (inches) (linear feet) 8"SDR35 PVC 1,227 8"CL350 D.I. 1,519 6. Does the subject gravity sewer collection system comply with the most recent version of the Gravity Sewer Minimum Design Criteria and 15A NCAC 211.0200? X Yes No. If no,please identify criteria and explain 7. Summary of PUMP STATIONS to be permitted: No.or Design Flow Pump Operational Pints Reliability Option Name (MGD) GPM feet TDH Selected N/A FORM: FTA 06/00 Page 3 of 5 i - -� - - 8. Summary of FORCE MAIN to be permitted: Diameter Length inches (linear feet) N/A 9. List any equipment being utilized that is not specifically mentioned elsewhere in the application or as part of the Minimum Design Criteria(e.g.,telemetry,hoist;odor control equipment,mechanical bar screens,etc.): N/A 10. Do the subject pump stations and force mains comply with the minimum Design Criteria for the Fast- Tract Permitting of Pump Stations and Force Mains documents adopted June 1,2000 and 15A NCAC 2H .0200? Yes; No. if no,please identify criteria and explain: N/A NOTE: If you responded NO to item IVA and/or item IV.10. above, two (2) copies of detailed plans, specifications, supporting information, and any other materials pertaining to the identified criteria should be submitted with the completed and appropriately executed application form. FORM: FTA 06/00 Page 4 of 5 V. CERTIFICATIONS Professional Engineer's Certification: h Robert Paul Patterson attest that this application for Can iage Park Section 9-Sewer Extension _ has been reviewed by me and is accurate,complete and consistent with the information supplied in the engineering plans,calculations,and all other supporting documentation to the best of my knowledge.I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations,Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996,and the Minimum Design Criteria for the Fast-Track Permitting of Pump Stations and Force Mains adopted June 1,2000. Although certain portions of this submittal package may have been developed by other professionals,inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design.Note:In accordance with NC General Statutes 143-215.6A and 143-215.613,any person who knowingly makes any Use statement,representation,or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed$10,000 as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's Seal,Signature,and Date: ,.`��oN CApli ,,, 9r AL EAL _01 0231131 :Z= OAUL_•pp�,O' Applicant's Certification: I, Ezra Allman,Director.attest that this application for Carriap_e Park.Section 9-Sewer Extension _ has been reviewed by me and is accurate and complete to the best of my knowledge.I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included,this application package will be returned to me as incomplete.Note: In accordance with NC General Statutes 143-215.6A and 143-215.613,any person who knowingly makes any false statement,representation.or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed$10,000 as well as civil penalties upto$25,000 per violation. C / Signature -I A/0. V�,zo—ti Date 1 JUL 2 5 2002 14I'n.TF r, �gCIAI ITY SECTION i JUL 2 2 2002 FORM: FTA 06/00 Pa e 5 of 5 --` `�- g IdCN-DISCHkFGE PEF.Wf-.F!r,:G