Loading...
HomeMy WebLinkAboutWQCS00091_Regional Office Physical File Scan Up To 1/4/2021Compliance Inspection Report Permit: WQCS00091 Effective: 05/24/18 Expiration: 03/31/26 owner: Town of Spruce Pine SOC: Effective: Expiration: Facility: Spruce Pine Collection System County: Mitchell PO Box 189 Region: Asheville Spruce Pine NC 28777 Contact Person: Phillip Wayne Hise Title: Public Works Director Phone: 828-765-3005 Directions to Facility: System Classifications: CS2, Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: NC0021423 Town of Spruce Pine - Spruce Pine WWTP Inspection Date: 07/19/2018 EntryTime: 10:OOAM Primary Inspector: Linda S Wiggs Secondary Inspector(s): Exit Time: 03:OOPM Phone: 828-296-4500 Ext.4653 Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Collection system management and operation Facility Status: ❑ Compliant ❑ Not Compliant Question Areas: r Miscellaneous Questions Performance Standards Operation & Maint Reqmts Records Monitoring & Rpting Reqmts Inspections Pump Station Manhole Lines (See attachment summary) Page: 1 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 07/1912018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine' Inspection Summary: I Low 5�1 B-r�fi IWO Page: 2 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 07/19/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Performance Standards and documented? Is Public Education Program for grease established and What educational tools are used? 0,0,1 /0 ) % / , Is Sewer Use Ordinance/Legal Authority available? \I / Does it appear that the Sewer Use Ordinance is enforced? Is Grease Trap Ordinance available? Is Septic Tank Ordinance available (as applicable, i.e. annexation) List enforcement actions by permittee, if any, in the last 12 months Has an acceptable Capital Improvement Plan (CIP) been implemented? Does CIP address short term needs and long term \"master plant/ concepts?. Does CIP cover three to five year period? Does CIP include Goal Statement? Does CIP include description of project area? . Does CIP include description of existing facilities? Does CIP include known deficiencies? Does CIP include forecasted future needs? Is CIP designated only for wastewater collection and treatment? Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Approximate capital improvement budget for collection system? Total annual revenue for wastewater collection and treatment? 6 J P""n ) CIP Comments Is system free of known points of bypass? If no, describe type of bypass and location Is a 24-hour notification sign posted at ALL pump stations? # Does the sign include: Instructions for notification? Pump station identifier? 24-hour contact numbers If no, list deficient pump stations # Do ALL pump stations have an "auto polling" feature/SCADA? Number of pump stations Number of pump stations that have SCADA Number of pump stations that have simple telemetry Number of pump stations that have only audible and visual alarms Number of pump stations that do not meet permit requirements # Does the permittee have a root control program? ❑ ❑ ❑ ❑ ARMUN1E SMIIN1A ❑ ❑ ❑ ❑ Page: 3 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 07/19/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine # If yes, date implemented? Describe: Comment: Inspections X Yes No NA NE Are maintenance records for sewer lines available? ❑ ❑ ❑ ❑ Are records available that document pump station inspections? \% ❑ ❑ ❑ ❑ Are SCADA or telemetry equipped pump stations inspected at least once a week? ❑ ❑ ❑ ❑ Are non-SCADA/telemetry equipped pump stations inspected every day? ❑ ❑ ❑ ❑ Are records available that document citizen complaints? ❑ ❑ ❑ ❑ # Do you have a system to conduct an annual observation o�� entire system? � ^tO�� El El ❑ El Has there been an observation of remote areas in the last ear? a-R �it ❑ ❑ ❑ ❑ Are records available that document inspections of high -priority lines? t� El El El El Has there been visual inspections of high -priority lines in last six months??" ❑ ❑ ❑ ❑ Comment: Operation & Maintenance Reauirements Yes No NA NE Are all log books available? �A4 00 k ❑ ❑ ❑ ❑ Does supervisor review all log books on a regular basis? ❑ ❑ ❑ ❑ Does the supervisor have plans to address documented short-term problem areas? ❑ ❑ ❑ ❑ What is the schedule for reviewing inspection, maintenance, & operations logs and problem areas? Are maintenance records for equipment available? ❑ ❑ ❑ ❑ Is a schedule maintained for testing emergency/standby equipment? ' ❑ ❑ ❑ ❑ What is the schedule for testing emergency/standby equipment? �� �/ ✓'`--t/a'�-C-, / ,��QGc/L'✓ Do pump station logs include: It Inside and outside cleaning and debris removal? ❑ ❑ ❑ ❑ Inspecting and exercising all valves? ❑ ❑ ❑ ❑ Inspecting and lubricating pumps and other equipment? ❑ ❑ ' ❑ ❑ Inspecting alarms, telemetry and auxiliary equipment? ❑ ❑ ❑ ❑ Is there at least one spare pump for each pump station w/o pump reliability? l ❑ ❑ ❑ Are maintenance records for right-of-ways available? VI h -r- MO "�, (/ ❑ ❑ ❑ ❑ Are right-of-ways currently accessible in the event of an emergency? CCCJJJ ❑ ❑ ❑ ❑ Are system cleaning records available? ❑ ❑ ❑ El Has at least 16 /° of system been cleaned annually? © 2-� O P Q %� ��� What areas are scheduled for cleaning in the next 12 months?---) liIkc Is a Spill Response Action Plan available? N3.00 ❑ ❑ ❑ ET-fV Does the plan include: 4-p XnQ �t 24-hour contact numbers ❑ ❑ ❑ ❑ � 4� /' &),/ /° r Page.- 4 /� Permit: WQCS00091 Owner -Facility: Town of Spruce Pine. Inspection Date: 07/19/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Response time ❑ ❑ ❑ ❑ Equipment list and spare parts inventory ❑ ❑ ❑ ❑ Access to cleaning equipment ❑ ❑ ❑ ❑ Access to construction crews, contractors, and/or engineers ❑ ❑ ❑ ❑ Source of emergency funds ❑ ❑ ❑ ❑ Site sanitation and cleanup materials Gar^' ❑ ❑ ❑ ❑ ` Post-overflow/spill assessment I ❑ ❑ ❑ ❑ Is a Spill Response Action Plan available for all personnel? ❑ ❑ ❑ ❑ Is the spare parts inventory adequate? ❑ ❑ ❑ ❑ Comment: Records Yes No NA NE Are adequate records of all SSOs, spills and complaints available? ❑ ❑ ❑ ❑ ® Are records of SSOs that are under the reportable threshold availab e? ❑ ❑ ❑ ❑ Do spill records indicate repeated overflows (2 or more in 12 months) at same location? ❑ ❑ ❑ ❑ If yes, is there a corrective action plan? ❑ ❑ ❑ ❑ Is a map of the system available? ❑ ❑ ❑ ❑ Does the map include: Pipe sizes ❑ ❑ ❑ ❑ Pipe materials Y ❑ ❑ ❑ ❑ Pipe location ❑ . ❑ ❑ ❑ Flow direction ❑ ❑ ❑ ❑ Approximate pipe age /V8 ❑ ❑ ❑ ❑ Number of service taps ❑ ❑ ❑ ❑ Pump stations and capacity ❑ ❑ ❑ ❑ If no, what percent is complete? List any modifications and extensions that need to be added to the map # Does the permittee have a copy of their permit? ❑ ❑ ❑ ❑ Comment: Monitoring and Reporting Requirements Yes No -NA NE Are copies of required press releases and distribution lists available? . ❑ ❑ ❑ ❑ Are public notices and proof of publication available? ❑ ❑ ❑ ❑ # Is an annual report being prepared in accordance with G.S. 143-215.1 C? ❑ ❑ ❑ ❑ # Is permittee compliant with all compliance schedules in the permits? tliT❑ ❑ ❑ ❑ If no, which one(s)? Comment: Page: 5 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 07/19/2018 Inspection Type : Collection System Inspect Non Sampling Lines/Right-of-Ways/Aerie) Lines Is right-of-way accessible for emergency? Is right-of-way free of sinkholes or depressions? Is line/right-of-way free of evidence of leakage? # Are there areas of exposed line? # Is any exposed line constructed of ductile iron or other approved material? Are water crossing and supports in good condition? # Is right-of-way free of non -utility motorized traffic? Is line free of visible damage? # Are there siphons in this system? If yes, are they maintained and documented? Comment: 2- Pump Station Pump station type Are pump station logs available? Is it accessible in all weather conditions? # Is general housekeeping acceptable? Are all pumps present? Are all pumps operable? Are wet wells free of excessive debris? Are upstream manholes free of excessive debris/signs of overflow? Are floats/controls for pumps/alarms operable? Is "auto polling" feature/SCADA present? Is "auto polling" feature/SCADA operational? Is simple telemetry present? Is simple telemetry operational? Are audio and visual alarms present? Are audio and visual alarms operable? Is the Pump station inspected as required? Are backflow devices in place? Are backflow devices operable? Are air relief valves in place? Are air relief valves operable? # Is an emergency generator available? Can the emergency generator run the pumps? Reason for Visit: Routine Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Page: 6 _ Permit: WQCS00091 Owner - Facility: Town of Spruce Pine _ Inspection Date: 07/19/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Is the pump station equipped for quick hook-up? ❑ ❑ ❑ ❑ Is the generator operable? ❑ ❑ ❑ ❑ # Is fuel in tank and sufficient? ❑ ❑ ❑ ❑ Is the generator inspected according to their schedule? ❑ ❑ ❑ ❑ Is a 24-hour notification sign posted? ❑ ❑ ❑ ❑ Does it include: Instructions for notification? ❑ ❑ ❑ ❑ Pump station identifier? ❑ ❑ ❑ ❑ Emergency phone number ❑ ❑ ❑ ❑ Is public access limited? ❑ ❑ ❑ ❑ Is pump station free of overflow piping? ❑ ❑ ❑ ❑ Is the pump station free of signs of overflow? ❑ ❑ ❑ ❑ Are run times comparable for multiple pumps? Comment: Manhole &r- Is manhole accessible? ��iri� �� Yes No NA NE V ❑ ❑ ❑ ❑ # Is manhole cover/vent above grade? Y >,/ % l/ ❑ ❑ ❑ ❑ Is the manhole free of visible signs of overflow? ❑ ❑ ❑ ❑ Is the manhole free of sinkholes 1,nd depressions?, ❑ ❑ ❑ ❑ Is manhole cover present? # ❑ ❑ ❑ ❑ Is manhole properly seated? ��� ❑ ❑ ❑ ❑ # Is manhole in good condition? C51"IYe- ❑ ❑ ❑ El�V/ # Is invert in good condition? ❑ ❑ El ❑ c�,,,�, Q Is line free -flowing and unrestricted in manhole? Y % / ❑ ❑ ❑ ❑ Is manhole free of excessive amounts of grease? ❑ ❑ ❑ ❑ Is manhole free of excessive roots? V ❑ ❑ ❑ ❑ Is manhole free of excessive sand? ----_ ❑ ❑ ❑ ❑ Is manhole's extended vent screened? )/ / ❑ ❑ ❑ ❑ Are vents free of submergence? ❑ ❑ ❑ ❑ Are manholes free of bypass structures or,pipes? ❑ ❑ ❑ ❑ Comment: % �1' 0,-0 2 Lines/Right-of-Ways/Aeriel Lines Yes Na NA NE Is right-of-way accessible for emergency? ❑ ❑ ❑ ❑ Is right-of-way free of sinkholes or depressions? ❑ ❑ ❑ ❑ Page: 7 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 07/19/2018 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Is line/right-of-way free of evidence of leakage? ❑ ❑ ❑ ❑ # Are there areas of exposed line? ❑ ❑ ❑ ❑ # Is any exposed line constructed of ductile iron or other approved material? ❑ ❑ ❑ ❑ Are water crossing and supports in good condition? ❑ ❑ ❑ ❑ # Is right-of-way free of non -utility motorized traffic? ❑ ❑ ❑ ❑ Is line free of visible damage? ❑ ❑ ❑ ❑ # Are there siphons in this system? ❑ ❑ ❑ ❑ If yes, are they maintained and documented? Comment: 1- Pump Station Yes No NA NE Pump station type Are pump station logs available? ❑ ❑ ❑ ❑ Is it accessible in all weather conditions? ❑ ❑ ❑ ❑ # Is general housekeeping acceptable? ❑ ❑ ❑ ❑ Are all pumps present? ❑ ❑ ❑ ❑ Are all pumps operable? ❑ ❑ ❑ ❑ Are wet wells free of excessive debris? ❑ ❑ ❑ ❑ Are upstream manholes free of excessive debris/signs of overflow? ❑ ❑ ❑ ❑ Are floats/controls for pumps/alarms operable? ❑ ❑ ❑ ❑ Is "auto polling" feature/SCADA present? ❑ ❑ ❑ ❑ Is "auto polling" feature/SCADA operational? ❑ ❑ ❑ ❑ Is simple telemetry present? ❑ ❑ ❑ ❑ Is simple telemetry operational? ❑ ❑ ❑ ❑ Are audio and visual alarms present? ❑ ❑ ❑ ❑ Are audio and visual alarms operable? ❑ ❑ ❑ ❑ Is the Pump station inspected as required? ❑ ❑ ❑ ❑ Are backflow, devices in place? ❑ ❑ ❑ ❑ Are backflow devices operable? ❑ ❑ ❑ ❑ Are air relief valves in place? ❑ ❑ ❑ ❑ Are air relief valves operable? ❑ ❑ ❑ ❑ # Is an emergency generator available? ❑ ❑ ❑ ❑ Can the emergency generator run the pumps? ❑ ❑ ❑ ❑ Is the pump station equipped for quick hook-up? ❑ ❑ ❑ ❑ Is the generator operable? ❑ ❑ ❑ ❑ # Is fuel in tank and sufficient? ❑ ❑ ❑ ❑ Page: 8 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 07/19/2018 Inspection Type : Collection System Inspect Non Sampling - Reason for Visit: Routine Is the generator inspected according to their schedule? Is a 24-hour notification sign posted? Does it include: Instructions for notification? Pump station identifier.? Emergency phone number Is public access limited? Is pump station free of overflow piping? Is the pump station free of signs of overflow? Are run times comparable for multiple pumps? Comment: 2- Manhole Is manhole accessible? # Is manhole cover/vent above grade? Is the manhole free of visible signs of overflow? Is the manhole free of sinkholes and depressions? Is manhole cover present? # Is manhole properly seated? # Is manhole in good condition? # Is invert in good condition? Is line free -flowing and unrestricted in manhole? Is manhole free of excessive amounts of grease? Is manhole free of excessive roots? Is manhole free of excessive sand? Is manhole's extended vent screened? Are vents free of submergence? Are manholes free of bypass structures or pipes? Comment: ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑❑❑ ❑ ❑ ❑ ❑ ❑ .❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Page: 9 I WATER POLLUTION CONTROL SYSTEM OPERATOR DESIGNATION FORM (WPCSOCC) NCAC 15A 8G .0201 Press TAB to enter information Permittee Owner/Officer Name: wo Ole Mailing Address: f>. 0. g cif Phone: City: c-so rLA-C�, A A State: VU C Zip: Email Address: -C.flMr, Signature:, , a/� Date: to / a / I S Facility Name: .SQrId_cer Pi V1 Cam' IGr�t ®n sy,5_rcm Permit # County: YOU MUST SUBMIT A SEPARATE FORM FOR EACH TYPE AND CLASSIFICATI Facility Type: Select Lu - UD. Facility Grade: Select Print Full Name: Certificate Type: Select Email Address: A I n C5 .•. �usourco; OF SYSTEM: OCT _ 4 20�8 thlater• �cra►; Work Phone: Certificate Grade: Select Certificate #: �a� ��� g Signature: W `tom Effective Date: "/ certify that/ agree to my designation as the Operator in Responsible Charge for the facility noted. 1 understand and will abide by the rules and regulations pertaining to the responsibilities of the ORC as set forth in 15A NCAC 08G .0204 and failing to do so can result in Disciplinary Actions by the Water Pollution Control System Operators Certification Commission." Print Full Name: Certificate Type: Select Email Address: Certificate Grade: Select Work Phone: Certificate #: Signature: Effective Date: "7 certify that/ agree to my designation as a Back-up Operator in Responsible Charge for the facility noted. / understand and will abide by the rules and regulations pertaining to the responsibilities of the ORC as set forth in 15A NCAC 08G .0204 and failing to do so can result in Disciplinary Actions by the Water Pollution Control System Operators Certification Commission." Mail; fax or email WPCSOCC, 1618 Mail Service Center, Fax: 919-715-2726 Email, certadmtn@ncd.enr gqv ORIGINAL to: Raleigh, NC 27699-1618 Mail or Fax Asheville a COPY to: 2090 US Hwy 70 Swannanoa, NC 28778 Fax:828-299-7043 Phone: 828-296-4500 Washington 943 Washington Sq. Mall Washington, NC 27889 Fax: 252-946-9215 Phone: 252-946-6481 Fayetteville 225 Green St., Suite 714 Fayetteville, NC 28301-5043 Fax:910-486-0707 Phone: 910-433-3300 Wilmington 127 Cardinal Dr. Wilmington, NC 28405-2845 Fax: 910-350-2004 Phone: 910-796-7215 Mooresville Raleigh 610 E. Center Ave., Suite 301 3800 Barrett Dr. Mooresville, NC 28115 Raleigh,.NC 27609 Fax:704-663-6040 Fax:919-571-4718 Phone:704-663-1699 Phone:919-791-4200 Winston-Salem , 45 W. Hanes Mall Rd. Winston-Salem, NC 27105 Fax: 336-776-9797 Phone: 336-776-9800 Revised 412016 WPCSOCC Operator Designation Form (continued) Page 2 Facility Name: Permit #: Print Full Name: Work Phone: Certificate Type:. Select Certificate Grade: Select . Certificate #: Email Address: Signature: Effective Date': "I certify that/ agree to my designation as a Back-up Operator in Responsible Charge for the facility noted. I understand and will abide by the rules and regulations pertaining to the responsibilities of the ORC as set forth in 15A NCAC 08G .0204 and failing to do so can result in Disciplinary Actions by the Water Pollution Control System Operators Certification Commission." — - -- --—r_._+. — ------ -- - - --- -- - -- - - -- „BACKUP G1RC F Print Full Name: Work Phone: Certificate Type: Select Certificate Grade: Select Certificate #: Email Address: Signature: Effective Date: "I certify that/ agree to my designation as a Back-up Operator in Responsible Charge for the facility noted. I understand and will abide by the rules and regulations pertaining to the responsibilities of the ORC as set forth in 15A NCAC 08G .0204 and failing to do so can result in Disciplinary Actions by the Water Pollution Control System Operators Certification Commission." _, ,.,gym ,. .., -_ .,..: _,, z •..: �. . .. _� � -.. ... .c z _ . ,. BACKUP�ORC Print Full Name: Work Phone: Certificate Type: Select Certificate Grade: Select Certificate #: Email Address: Signature: Effective Date: "I certify that I agree to my designation as a Back-up Operator in Responsible Charge for the facility noted. I understand and will abide by the rules and regulations pertaining to the responsibilities of the ORC as set forth in 15A NCAC 08G .0204 and failing to do so can result in Disciplinary Actions by the Water Pollution Control System Operators Certification Commission." Print Full Name: Certificate Type: Select Certificate Grade: Select Email Address: Signature: Work Phone: Certificate #: Effective Date: "I certify that/ agree to my designation as a Back-up Operator in Responsible Charge for the facility noted. 1 understand and will abide by the rules and regulations pertaining to the responsibilities of the ORC as set forth in 15A NCAC 08G .0204 and failing to do so can result in Disciplinary Actions by the Water Pollution Control System Operators Certification Commission." Revised 412016 Wa ter Resources ENVIRONMENTAL QUALITY May 24, 2018 Mr. Phillip Hise, Public Works Director Town of Spruce Pine PO Box 189 Spruce Pine, NC 28777 Subject: Permit No. WQCS00091 Town of Spruce Pine Town of Spruce Pine Collection System Mitchell County Dear Mr. Hise: ROY COOPER (.lovevv ol. MICHAEL S. REGAN Secrelnn LINDA CULPEPPER brlerim Directrvr In accordance with your application received March 28, 2018, we are forwarding herewith Permit No. WQCS00091, dated May 24, 2018, to the Town of Spruce Pine for the operation and maintenance of the subject wastewater collection system. This permit shall be effective from May 24, 2018 until March 31, 2026, and shall be subject to the conditions and limitations specified herein. It is your responsibility to thoroughly review this permit. Please pay particular attention to the monitoring and reporting requirements in this permit and any special conditions. Changes have been made to the boiler plate language of the permit. Most of the changes are for clarification purposes, however Condition 1(3) has been removed. The Department of Environmental Quality (DEQ) believes that condition was included erroneously in previous permits. It was included based on proposed. rulemaking by EPA which was never promulgated and, in the continued absence of Federal regulations, DEQ lacks authority to include such language in a permit. DEQ will continue to exercise enforcement discretion when evaluating sanitary sewer overflows that maybe considered to be beyond the reasonable control of the Permittee. A highlighted copy of, -the permit identifying the changes made is available at: http://ncdenr.s3.amazonaws.com/s3fs-, public/Water%20Qua lity/Surface%2OWater%2OProtection/PERCS/WCS%20(Collection%20System)/Updated %20WQCS%20Template%2015.05.18%20(highlighted).Pdf For purposes of permitting, the collection system is considered to be any existing or newly installed system extension up to the wastewater treatment facility property or point of connection with a separately owned sewer system. The collection system is considered all gravity lines, pump stations, force mains, low pressure sewer systems, STEP systems, vacuum systems,. etc. and associated piping, valves and appurtenances that help to collect, manage and transport wastewater to a wastewater treatment plant under the Permittee's ownership or maintained and operated by the Permittee through a perpetual legal agreement. Satellite systems are systems tributary to the Permittee's collection system but those collection systems are not owned or maintained by the Permittee. The system description provided on Page 1 of this permit,is meant to provide a general idea about the size of the system and may not be all inclusive of the collection system at the time of permit issuance or afterward. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Phone: 919-807-6300 \ Internet: www.ncwaterquality.org An Equal Opportunity 1 Affirmative Action Employer— Made In part by recycled paper Town of Spruce Pine Collection System May 24, 2018 A discharge of wastewater to the environment from the Permittee's wastewater collection system prior to reaching the wastewater treatment facilities is referred to herein as a Sanitary Sewer Overflow (SSO). The evaluation of enforcement options after an SSO will be determined considering all relevant information available or.requested of the Permittee. Compliance with all conditions of the permit as well as all statutes and regulations pertaining to the wastewater collection system must be maintained or appropriate enforcement actions may be taken as noted in Condition VI(2). A reportable SSO is an SSO greater than 1,000 gallons to the ground or an SSO of any amount that reaches surface water (including through ditches, storm drains, etc.). Reporting requirements including the required verbal report and written report to the appropriate regional office are referenced in Condition IV(2). Form CS-SSO can be downloaded from the SSO Reporting area at: http://ncdenr.s3.amazonaws.com/s3fs- public/Water%20Qual ity/Surface%2OWater%20Protection/PERCS/WCS%20(SSO%2ODocuments)/CS- SSO(2015).doc A notice of deficiency (NOD), notice of violation (NOV), civil penalty, and/or a moratorium on the addition of waste to the system may be issued if adequate justification for an SSO is NOT submitted to the regional office. In order to submit a claim for justification of an SSO, you must use Part II of form CS-SSO with additional documentation as necessary. DWR staff will review the justification claim and determine if enforcement action is appropriate. Please be advised that the information needed to justify a spill is very comprehensive. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty days following the receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you have questions regarding compliance, contact the appropriate regional office. If you need additional information concerning this permit, please contact Steve Lewis at (919) 807-6308. Sincerely; for Linda Culpepper Interim Director, Division of Water Resources by Deborah Gore, Supervisor Pretreatment, Emergency Response, Collection System Unit (PERCS) enclosure: Permit No. WQCS00091 cc: Asheville Regional Office, Water Quality Regional Operations (electronic) Water Resources Central Files — WQCS00091(electronic) Maureen Kinney, NC Operators Certification Program (electronic) PERCS Files (electronic) ) STATE OF NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENTAL QUALITY SYSTEM -WIDE COLLECTION SYSTEM PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted to the Town of Spruce Pine WQCS00091 FOR THE operation and maintenance of a wastewater collection system consisting of, at the time of permit issuance, approximately 35 miles of gravity sewer, approximately 15 miles of force main, 14 duplex pump stations, and all associated piping, valves, and appurtenances required to make a complete and operational wastewater collection system to serve the Town of Spruce Pine and any deemed permitted satellite communities, pursuant to the application received March 28, 2018, and in conformity with the documents referenced therein and other supporting data subsequently filed and approved by the Department of Environmental Quality and considered a part of this permit. This permit shall be effective from May 24, 2018 until March 31, 2026, and shall be subject to the following specified conditions and limitations: Page 1 of 7 I. PERFORMANCE STANDARDS The sewage and wastewater collected by this system shall be treated in the properly permitted Wastewater Treatment Facility identified in the permit application and documented in the Division's database. [15A NCAC 02T .0108 (b)] 2. The wastewater collection system shall be effectively managed, maintained and operated at all times to prevent discharge to land or surface waters, and to prevent any contravention of groundwater standards or surface water standards. In the event that the wastewater collection system fails to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate actions as per the Response Action Plan (Condition II(9)), as well as any actions that may be required by the Division of Water Resources (Division), such as the construction of additional or replacement sewer lines and/or equipment. [15A NCAC 02T .0108 (b)]. The Permittee shall establish by ordinance, inter -local agreement or contract its legal authority to require new sewers be properly constructed; to ensure proper inspection and testing of sewer mains and service laterals; to address flows from satellite systems and to take enforcement action as required by Condition 1(4). [G.S. 143-215.98; G.S. 143-215.1(f)(1)] The Permittee shall develop and implement an educational fats, oils and grease program that shall include at least semiannual distribution of educational material targeted at both residential and non- residential users. The Permittee shall also develop and implement an enforceable fats, oils and grease program for non-residential users under which the Permittee can take enforcement against users who have not properly installed, operated and maintained grease traps or grease interceptors as directed or otherwise violated the terms of the enforcement program pertaining to fats, oils and grease. [15A NCAC 02T .0108 (b)] The Permittee shall adopt and implement a Capital Improvement Plan (CIP) to designate funding for reinvestment into the wastewater collection system infrastructure. The CIP should address the short- term needs and long-term "master plan" concepts. The CIP should typically cover a three to five year period and'include a goal statement, description of the project area, description of the existing facilities, known deficiencies (over a reasonable period) and forecasted future needs. Cost analysis is integral to the CIP. [G.S. 143-215.9B] 6. Overflow piping from manholes and pump stations, excluding piping to approved equalization structures, known or discovered after permit issuance shall be immediately removed or permanently capped. Plugged or valved emergency pumping connections are allowable for portable pumping or rerouting without intentionally bypassing the wastewater treatment facility. [15A NCAC 02T .0108 (b)] The Permittee shall maintain a contingency plan for pump failure at each pump station. If one of the pumps in a pump station containing multiple pumps fails, the process of repairing or replacing the pump shall be initiated immediately and the new parts or pump shall be installed as soon as possible. The permittee shall provide justification for delay in initiating the process for repair or replacement at the Division's request. If the pump in a simplex pump station serving more than a single building or pump stations not capable of pumping at a rate of 2.5 times the average daily flow rate with the largest pump out of service fails, it shall be replaced immediately. [15A NCAC 02T .0305 (h) (1)] Page 2 of 7 8. Each pump station shall be clearly and conspicuously posted with a pump station identifier and an emergency contact telephone number at which an individual who can initiate or perform emergency service for the wastewater collection system 24 hours per day, seven days per week can be contacted. This emergency contact telephone number shall be coupled with instructions that the emergency contact should be called if the visual alarm illuminates, if the audible alarm sounds, or if an emergency is apparent. [15A NCAC 02T .0305 (h) (2)] 9. Pump station sites, equipment and components shall have restricted access. [15A NCAC 02T .0305 (h) (4)] 10. Pump stations that do not employ an automatic polling feature (i.e. routine contact with pump stations from a central location to check operational status of the communication system) shall have both audible and visual high water alarms. The alarms shall be weather-proof and placed in a clear and conspicuous location. Permits issued for the construction of pump stations that included high water alarms in the description must maintain the alarms even if simple telemetry (i.e. notification of an alarm condition initiated by the pump station control feature) is installed. [15A NCAC 02T .0305 (h) (1)] 11. For all newly constructed, modified and rehabilitated pump stations, all equipment and components shall be sealed within a corrosion -resistant coating or encasement to the extent practicable and equivalent to the minimum design criteria unless the permittee can demonstrate it is not practicable or another form of corrosion resistance is employed. [15A NCAC 02T .0108 (b)] II. OPERATION AND MAINTENANCE REQUIREMENTS 1. Upon classification of the collection system by the Water Pollution Control System Operators Certification Commission (WPCSOCC), the Permittee shall designate and employ a certified operator to be in responsible charge (ORC) and one or more certified operator(s) to be back-up ORC(s) of the facilities in accordance with 15A NCAC 8G .0201. The-ORC shall visit the system within 24 hours of knowledge of a bypass, spill, or overflow of wastewater from the system, unless visited by the Back -Up ORC, and shall comply with all other conditions of 15A NCAC 8G .0204. [15A NCAC 08G .0200 et.seq.] The Permittee shall develop and adhere to a schedule for reviewing all inspection, maintenance, operational and complaint logs. If the review process results in the identification of any recurring problem in the wastewater collection system that cannot be resolved in a short time period, the Permittee shall establish a plan for addressing the problem(s). [15A NCAC 02T .0108 (b)] 3. The Permittee shall develop and adhere to a schedule for testing emergency and standby equipment. [15A NCAC 02T .0108 (b)] 4. The Permittee shall develop and implement a routine pump station inspection and maintenance program which shall include the following maintenance activities: a. Cleaning and removing debris from the pump station structure, outside perimeter, and wet well; b. Inspecting and exercising all valves; c. Inspecting and lubricating pumps and other mechanical equipment; and d. Verifying the proper operation of the alarms, telemetry system and auxiliary equipment. [15A NCAC 02T .0108 (b)] Page 3 of 7 5. For each pump station without pump reliability (i.e. simplex pump stations serving more than a single building or pump stations not capable of pumping at a rate of 2.5 times the average daily flow rate with the largest pump out of service), at least one fully operational spare pump capable of pumping peak flow shall be maintained on hand. [15A NCAC 02T .0305 (h) (1) (A)] The Permittee shall maintain on hand at least two percent of the number of pumps installed, but no less than two pumps, that discharge to a pressure sewer and serve a single building, unless the Permittee has the ability to purchase and install a replacement pump within 24 hours of first knowledge of the simplex pump failure or within the storage capacity provided in a sewer line extension permit. [15A NCAC 02T .0108 (b)] Rights -of -way and/or easements shall be properly maintained to allow accessibility to the wastewater collection system unless the Permittee can demonstrate the ability to gain temporary access in an emergency situation where existing land -use conditions do not allow the establishment and maintenance of permanent access. In this case, the Permittee shall continue to observe the lines visually; utilize remote inspection methods (e.g. CCTV) and use the opportunity of drier conditions to perform further inspections and necessary maintenance. [15A NCAC 02T .0108 (b)] 8. The Permittee shall assess cleaning needs, and develop and implement a program for appropriately cleaning, whether by hydraulic or mechanical methods, the wastewater collection system. At least 10 percent of the gravity wastewater collection system, selected at the discretion of the ORC, shall be cleaned each year. Preventative cleaning is not required for sewer lines less than five years old unless inspection otherwise reveals the need for cleaning or cleaning is required by a sewer line extension permit. [15A NCAC 02T .0108 (b)] 9. The Permittee shall maintain a Response Action Plan that addresses the following minimum items: a. Contact phone numbers for 24-hour response, including weekends and holidays; b. Response time; c. Equipment list and spare parts inventory; d. Access to cleaning equipment; e. Access to construction crews, contractors and/or engineers; f. Source(s) of emergency funds; g. Site restoration and clean up materials; and h. Post-SSO assessment. [15A NCAC 02T .0108 (b)] 10. The Permittee, or their authorized representative, shall conduct an on -site evaluation for all SSOs as soon as possible, but if feasible no more than two hours after first knowledge of the SSO. The Permittee shall document in its 5-day report why it was unable to initially respond to any SSO location within two hours. [15A NCAC 02T .0108 (b)] 11. In the event of an SSO or blockage within the wastewater collection system, the Permittee shall restore the system operation, remove visible solids and paper, restore any ground area and restore the surroundings. [15A NCAC 02T .0108 (b)] III. RECORDS 1. Records shall be maintained to document compliance with Conditions 1(4), 11(2) - II(4), 11(7) - II(8), IV(3) and V(1) -V(4). Records shall be kept on file for a minimum of three years. [15A NCAC 02T .0108 (b)] Page 4 of 7 2. The Permittee shall maintain adequate records pertaining to SSOs, and SSO or wastewater collection system complaints for a minimum of three years. These records shall include, but are not limited to, the following information: a. Date of SSO or complaint; b. Volume of wastewater released as a result of the SSO and/or nature of complaint; C. Location of the SSO and/or complaint; d. Estimated duration of the SSO; e. Individual from the Division who was informed about the SSO and/or complaint, when applicable; . f. Final destination of the SSO; g. Corrective actions; h. Known environmental/human health impacts resulting from the SSO; and i. How the SSO was discovered. [15A NCAC 02T .0108 (b)] 3. The Permittee shall maintain an up-to-date, accurate; comprehensive map of its wastewater collection system that also notes the locations where other wastewater collection systems become tributary. If a comprehensive map of the collection system has not been established, a rough sketch shall be drawn. The Permittee shall map approximately 10 percent of its existing collection system each year for the next ten years beginning at the original permit issuance date, or until complete, whichever is sooner. The comprehensive map shall include, but is not limited to: pipe size, pipe material, pipe location, flow direction, approximate pipe age, and each pump station identification, location and capacity. [15A NCAC 02T .0108 (b)] 4. The Permittee shall maintain records of all of the modifications and extensions to the collection system permitted herein. The Permittee shall maintain a copy of the construction record drawings and specifications for modifications/extensions to the wastewater collection system for the life of the modification/extension. Information concerning the extension shall be incorporated into the map of the wastewater collection system within one year of the completion of construction. The system description contained within this permit shall be updated to include this modificatioh/extension information upon permit renewal. [15A NCAC 02T .0108 (b)] IV. MONITORING AND REPORTING REQUIREMENTS 1. In the event of an SSO the Division may require monitoring that is necessary to ensure surface water and groundwater_ protection and an acceptable sampling and reporting schedule shall be implemented. [15A NCAC 02T .0108 (c)] 2. The Permittee shall verbally report to a Division of Water Resources staff member at the Asheville Regional Office, at telephone number (828) 296-4500 as soon as possible, but in no case more than 24 hours following first knowledge of the occurrence of the following circumstances within the collection system which is under the Permittee's ownership or maintained and operated by the Permittee through a perpetual legal agreement: ' a. Any SSO and/or spillover 1,000 gallons to the ground; or b. Any SSO and/or spill, regardless of volume, that reaches surface water. Voice mail messages or faxed information shall not be considered as the initial verbal report. SSOs (and other types of spills) occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Page 5 of 7 Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS- SSO (or the most current Division approved form), within five business days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. [G.S. 143-215.1C(a1)] 3. The Permittee shall meet the annual reporting and notification requirements provided in North Carolina General Statute §143-215.1C. V. INSPECTIONS The Permittee or the Permittee's designee shall inspect the wastewater collection system regularly to reduce the risk of malfunctions and deterioration, operator errors, and other issues that may cause or lead to the release of wastes to the environment, threaten human health or create nuisance conditions. The Permittee shall keep an inspection log or summary including, at a minimum, the date and time of inspection, observations made, and any maintenance, repairs, or corrective actions taken by the Permittee. [15A NCAC 02T .0108 (b)] Pump stations that are not connected to a telemetry system (i.e,, remote alarm system) shall be inspected by the permittee or its representative everyday -(i.e., 365 days per year). Pump stations that are connected to telemetry shall be inspected at least once per week. [15A NCAC 02T .0108 (b)] A general observation by the permittee or its representative of the entire wastewater collection system shall be conducted at least once per year. [15A NCAC 02T .0108 (b)] 4. Inspections of all high priority lines (i.e. aerial line, sub -waterway crossing, line contacting surface waters, siphon, line positioned parallel to stream banks that are subject to eroding in such a manner that may threaten the sewer line, or line designated as high -priority in a permit) shall be performed at least once per every six-month period of time. A list of high -priority lines is presented as Attachment A and is hereby incorporated into this permit condition. New high priority lines installed or identified after permit issuance are incorporated by reference and subject to this permit condition until permit renewal where they shall be referenced in writing in Attachment A. [15A NCAC 02T .0108 (b)] VI. GENERAL CONDITIONS 1. This permit is not transferable. In the event that the Permittee desires to transfer ownership of the wastewater collection system or there is a name change of the Permittee, a formal permit modification request shall be submitted to the Division. The request shall be accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. Such request will be considered on its merits and may or may not be approved. [15A NCAC 02T .0104; G.S. 143-215.1(d)(3)] 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, and a sewer moratorium may be established. [15A NCAC 02T .0104] 3. The issuance of this permit does not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (i.e., local, state, and federal) having jurisdiction. [G.S.143-215.1(b)] 4. The issuance of this permit does not prohibit the Division from reopening and modifying the permit, revoking and reissuing the permit or terminating the permit as allowed by the laws, rules, and regulations or as needed to address changes in federal regulations with respect to the wastewater collection system, in accordance with required procedures. [G.S. 143-215.1(b)(4)] Page 6 of 7 5. The Permittee shall pay the annual fee within thirty (30) days after being billed by the Division. Failure to pay the fee accordingly may cause the Division to initiate action to revoke this permit. [15A NCAC 02T .0110 (4)] 6. The Permittee shall file an application for renewal of this permit at least six months prior to the expiration of this permit. Upon receipt of the request, the Director will review the adequacy of the wastewater collection system described therein, and if warranted, will extend the permit for a period Of time and under such conditions and limitations, as the Director may deem appropriate. [15A NCAC 02T .0109] 7. The Permittee shall notify the Division's Pretreatment, Emergency Response and Collection Systems Unit in writing at 1617 Mail Service Center, Raleigh, North Carolina 27699 of any changes to the name and/or address of the responsible party (i.e. mayor, city/town manager) of the wastewater collection system. [15A NCAC 02T .0106 (c)] Any duly authorized officer, employee, or representative of the Division may, upon presentation of credentials, enter and inspect any property, -pre mises or place on or related to the collection system at any reasonable time for the purpose of determining compliance with this permit, may inspect or copy any records that must be maintained under the terms and conditions of this permit, and may obtain samples of wastewater, groundwater, surface water, soil, or plant tissue. [15A NCAC 02T .0110 (3)] 9. The Permittee or their authorized representative shall have available a copy of this permit to present upon request by any duly authorized officer, employee, or representative of the Division. [15A NCAC 02T .0104] Permit issued this the 24th of May, 2018 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Linda Culpepper Interim Director, Division of Water Resources By Authority of the Environmental Management Commission by Deborah Gore, Pretreatment, Emergency Response, Collection System Unit Supervisor Division of Water Resources, NCDEQ Page 7 of 7 .L„V.0 Spruce P1ne, NC Attachment A for Condition V (4) Permit # W QCS00091 High Priority Lines Main interceptor parallel to North Toe River Line from Shannon Drive to W WTP under Toe River Collection line from East side of Town. under Toe River Town of Spruce Pine Waste Water Pump Station Information Description "Type Pumps HP GPM Mfgr Alarm Beaver Creek Sewer 2 20 900 Fairbanks Audio/ & Visual Prison #1 Sewer 2 50 410 Fairbanks Audio/ & Visual Prison #1 Sewer 2 30 410 Fairbanks Audio/ & Visual Burleson Hill Sewer 2 30 200 Fairbanks Audio/ & Visual Locust Ave Sewer 2 1 100 Fairbanks Audio/ & Visual Feldspar Sewer 2 8 200 Fairbanks Audio/ & Visual Carters Ridge Sewer 2 50 175 Fairbanks Audio/ & Visual. Shannon Drive Sewer 2 3 50 Hydromatic Audio/ & Visual Sullins Branch Sewer 2 5 50 Hydromatic Audio/ & Visual Pine Branch Sewer 2 3 50 Hydromatic Audio/ & Visual Sunnybrook Dr Sewer 2 11 100 Fairbanks Audio/ & Visual Duncan Street Sewer 1 2 50 Fairbanks Audio/ & Visual Henredon Sewer 2 10 300 Fairbanks Audio/ & Visual MHS Sewer 2 30 90 Keen Audio/ & Visual Aux. Power Generator Generator Generator Generator Generator Generator Generator Compliance Inspection Report Permit: WQCS00091 Effective: 04/01/13 Expiration: 03/31/18 owner: Town of Spruce Pine SOC: Effective: Expiration: Facility: Spruce Pine Collection System. County: Mitchell PO Box 189 Region: Asheville Spruce Pine NC 28777 Contact Person: Richard Canipe Title: Town Manager Phone: 828-765-3000 Directions to Facility: System Classifications: CS2, Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: NC0021423 Town of Spruce Pine - Spruce Pine WWTP Inspection Date: 08/10/2015 Entry Time: 01:OOPM Primary Inspector: Linda S Wiggs Secondary Inspector(s): Exit Time: 03:OOPM Phone: 828-296-4500 Ext.4653 Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Collection system management and operation Facility Status: ❑ Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions Performance Standards Operation & Maint Reqmts Records Monitoring & Rpting Reqmts Inspections Pump Station Manhole Lines (See attachment summary) Page: 1 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 08110/2015 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: CIA-- L ate- GYM- _ �- 5 Page: 2 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 08/10/2015 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Gb� Performance Standards Yes No NA NE YJ1 Is Public Education Program for grease established and documented? �s ❑ ❑ ❑ ❑ What educational tools are used? Is Sewer Use Ordinance/Legal Authority available? ❑ ❑ ❑ ❑ Does it appear that the Sewer Use Ordinance is enforced? ❑ ❑ ❑ ❑ Is Grease Trap Ordinance available? ❑ ❑ ❑ ❑ Is Septic Tank Ordinance available (as applicable, i.e. annexation) ❑ ❑ ❑ ❑ List enforcement actions by permittee, if any, in the last 12 months Has an acceptable Capital Improvement Plan (CIP) been implemented? ❑ ❑ ❑ ❑ Does CIP address.short term needs and long term \"master plan\" concepts? ❑ ❑ ❑ ❑ Does CIP cover three to five year period? ❑ ❑ ❑ ❑ Does CIP include Goal Statement? ❑ ❑ ❑ ❑ Does CIP include description of project area? ❑ ❑ ❑ ❑ Does CIP include description of existing facilities? ❑ ❑ ❑ ❑ Does CIP include known deficiencies? ❑ ❑ ❑ ❑ Does CIP include forecasted future needs? ❑ ❑ ❑ ❑ Is CIP designated only for wastewater collection and treatment? ❑ ❑ ❑ ❑ Approximate capital improvement budget for collection system? Total annual revenue for wastewater collection and treatment? CIP Comments Is system free of known points of bypass? ❑ ❑ ❑ ❑ If no, describe type of bypass and location Is a 24-hour notification sign posted at ALL pump stations? ❑ ❑ ❑ ❑ # Does the sign include: Instructions for notification? ❑ ❑ ❑ ❑ Pump station identifier? ❑ ❑ ❑ ❑ 24-hour contact numbers ❑ ❑ ❑ ❑ If no, list deficient pump stations # Do ALL pump stations have an "auto polling" feature/SCADA? ❑ ❑ ❑ ❑, Number of pump stations Number of pump stations that have SCADA Number of pump stations that have simple telemetry Number of pump stations that have only audible and visual alarms Number of pump stations that do not meet permit requirements # Does the permittee have a root control program? ❑ ❑ ❑ ❑ Page: 3 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 08/10/2015 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine # If yes, date implemented? Describe: Comment: Inspections Yes No NA NE Are maintenance records for sewer lines available? ❑ ❑ ❑ ❑ Are rb�ordsvailable that document pump station inspections? ❑❑❑ ❑AreStelemetry equipped pump stations inspected at least once a week? ❑ ❑ ❑ ❑ Are non-SCADA/telemetry equipped pump stations inspected every day? ❑ ❑ ❑ ❑ Are records available that ooument citizen complaints? ❑ ❑ ❑ ❑ # Do you have a system to conduct a� n annual observation of entire system? Li Li Li Li # Has there been an observation of:emote,in the last year? ❑ El ❑ ❑ Are records available that document inspections f high -priority lines? ❑ ❑ ❑ ❑ Has there been visual inspections of high -priority lines mast six months? ❑ ❑ ❑ ❑ Comment: Operation & Maintenance Requirements � Yes No NA NE Are all log books available? ❑ ❑ ❑ ❑ Does supervisor review all log books on a regular basis? ❑ ❑ ❑ ❑ Does the supervisor have plans to address documented short-term problem areas? ❑ ❑ ❑ ❑ What is the schedule for reviewing inspection, maintenance, & operations logs and problem areas? Are mairit. nance records for equipment available? ❑ ❑ ❑ ❑ Is a schedule Maintained for testing emergency/standby equipment? ❑ ❑ ❑ ❑ What is the schedule for testing emergency/standby equipment? Do pump station logs i�tclude: Inside and outside ceaning and debris removal? ❑ ❑ ❑ ❑ Inspecting and exercising all valves? ❑ ❑ ❑ ❑ sander equipment? Inspecting and lubricating pur31\uxilriary ❑ ❑ ❑ ❑ Inspecting alarms, telemetry aequipment?Is there at least one spare pump fomp station w/o pump reliability? ❑ ❑ ❑ ❑Are maintenance records for right-`ilable? ❑ ❑ ❑ ❑ Are right-of-ways currently accessible in the event of an emergency? ❑ ❑. ❑ ❑ Are system cleaning records available? \ ❑ ❑ ❑ ❑ Has at least 10% of system been cleaned annually?,,., ❑ ❑ ❑ ❑ What areas are scheduled for cleaning in the next 12 months? Is a Spill Response Action Plan available? 111111 ❑ Does the plan include: 24-hour contact numbers ❑ ❑ ❑ ❑ Page: 4 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 08/10/2015 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Response time Equipment list and spare parts inventory Access to cleaning equipment Access to construction crews, contractors, and/or engineers Source of emergency funds n Site sanitation and cleanup materials Post-overflow/spill assessment . Is a Spill Response Action Plan available for all personnel? Is the spare parts inventory adequate? Comment: Records Are adequate records of all SSOs, spills and complaints available? Are records of SSOs that are under the reportable threshold available? Do spill records indicate repeated overflows (2 or more in 12 months) at same location? If yes, is there a corrective action plan? Is a map of the system available? Does the map include: Pipe sizes Pipe materials Pipe location Flow direction Approximate pipe age Number of service taps Pump stations and capacity If no, what percent is complete? List any modifications and extensions that need to be added to the map # Does the permittee have a copy of their permit? Comment: Monitoring and Reporting Requirements Are copies of required press releases and distribution lists availableT Are public notices and proof of publication available? # Is an annual report being prepared in accordance with G.S. 143-215.1C? # Is permittee compliant with all compliance schedules in the permits? qP If no, which one(s)? Comment: ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Page: 5 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 08/10/2015 Inspection Type: Collection System Inspect Non Sampling Reason for visit: Routine Lines/Right-of-WaysMeriel Lines Yes No NA NE Is right-of-way accessible for emergency? ❑ ❑ ❑ ❑ Is right-of-way free of sinkholes or depressions? ❑ ❑ ❑ ❑ Is line/right-of-way free of eviden a of leakage? ❑ ❑ ❑ ❑ # Are there areas of exposed line ❑ ❑ ❑ ❑ # Is any exposed line constructed o ductile iron or other approved material? ❑ ❑ ❑ ❑ Are water crossing and supports in good condition? El ❑ ❑ El # is right-of-way free of non -utility motored traffic? ❑ ❑ ❑ ❑ Is line free of visible damage? ❑ ❑ ❑ ❑ # Are there siphons in this system? ❑ ❑ ❑ ❑ If yes, are they maintained and documented? Comment: 1- \ / Puma Station \ J/ Yes No NA NE Pump station type r Are pump station logs available? ❑ ❑ ❑ ❑ Is it accessible in all weather conditions? 1 ❑ ❑ ❑ ❑ # Is general housekeeping acceptable? ❑ ❑ ❑ ❑ Are all pumps present? ❑ ❑ ❑ ❑ Are all pumps operable? ❑ ❑ ❑ ❑ Are wet wells free of excessive debris? ❑ ❑ ❑ ❑ Are upstream manholes free of excessive debris/signs of overflow? ❑ ❑ ❑ ❑ Are floats/controls for pumps/alarms operable? ❑ ❑ ❑ ❑ Is "auto polling" feature/SCADA present? ❑ ❑ ❑ ❑ Is "auto polling" feature/SCADA operational? ❑ ❑ ❑ ❑ Is simple telemetry present? ❑ ❑ ❑ ❑ Is simple telemetry operational? ❑ ❑ ❑ ❑ Are audio and visual alarms present? ❑ ❑ ❑ ❑ Are audio and visual alarms operable? ❑ ❑ ❑ ❑ Is the Pump station inspected as required? ❑ ❑ ❑ ❑ Are backflow devices in place? ❑ ❑ ❑ ❑ Are backflow devices operable? ❑ ❑ ❑ Are air relief valves in place? ❑ ❑ ❑ ❑ Are air relief valves operable? ❑ ❑ ❑ ❑ # Is an emergency generator available? ❑ ❑ ❑ ❑ i Can the emergency generator run the pumps? ❑ ❑ ❑ ❑ Page: 6 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: O8/10/2015 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Is the pump station equipped for quick hook-up? ❑ ❑ ❑ ❑ Is the generator operable? ❑ ❑ ❑ ❑ # Is fuel in tank and sufficient? ❑ ❑ ❑ ❑ Is the generator inspected according to their schedule? ❑ ❑ ❑ ❑ Is a 24-hour notificatiop sign posted? ❑ ❑ ❑ ❑ Does it include: Instructions for notification? Pump station identifier? Emergency phone numb\piping? Is public access limited? Is pump station free of overfl Is the pump'station free of signs of overflow? Are run times comparable for multiple pumps? Comment: 2- Pump Station Pump station type Are pump station logs available? Is it accessible in all weather conditions? # Is general housekeeping acceptable? Are all pumps present? Are all pumps operable? Are wet wells free of excessive debris? Are upstream manholes free of excessive debris/signs bf overflow? Are floats/controls for pumps/alarms operable? Is "auto polling" feature/SCADA present? Is "auto polling" feature/SCADA operational? , Is simple telemetry present? Is simple telemetry operational? / Are audio and visual alarms present? Are audio and visual alarms operable?I r Is the Pump station inspected as required? Are backflow devices in place? Are backflow devices operable? Are air relief valves in place? Are air relief valves operable? ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Page: " 7 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 08/10/2015 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine # Is an emergency generator available? Can the emergency generator run the pumps? Is the pump station equipped for quick hook-up? Is the generator operable? # Is fuel in tank and sufficient? Is the generator inspected according to their Is a 24-hour notification sign posted? Does it include: Instructions for notification? Pump station identifier? Emergency phone number Is public access limited? Is pump station free of overflow piping? Is the pump station free of signs of overflow? Are run times comparable for multiple pumps Comment: 2- Manhole Is manhole accessible? # Is manhole cover/vent above grade? Is the manhole free of visible signs of overflo Is the manhole free of sinkholes and depress Is manhole cover present? # Is manhole properly seated? # Is manhole in good condition? # Is invert in good condition? Is line free -flowing and unrestricted in manhole? Is manhole free of excessive amounts of grease? Is manhole free of excessive roots? Is manhole free of excessive sand? Is manhole's extended vent screened? Are vents free of submergence? Are manholes free of bypass structures or pipes? Comment: 1- Manhole ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ .❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE Page: 8 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine ' Inspection Date: 08/10/2015 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Is manhole accessible? # Is manhole cover/vent above grade? Is the manhole free of visible signs of overflow? Is the manhole free of sinkholes and depressions? Is manhole cover present? # Is manhole properly seated? # Is manhole in good condition? # Is invert in good condition? Is line free -flowing and unrestricted in manhole? Is manhole free of excessive amounts of grease? Is manhole free of excessive roots? Is manhole free of excessive sand? Is manhole's extended vent screened? Are vents free of submergence? Are manholes free of bypass structures or pipes? Comment: 3. -�Manhole ` Is manhole accessible? # Is manhole cover/vent above grade? Is the manhole free of visible signs of overflow? Is the manhole free of sinkholes and depressions? Is manhole cover present? # Is manhole properly seated? # Is manhole in good condition? # Is invert in good condition? Is line free -flowing and unrestricted in manhole? Is manhole free of excessive amounts of grease? Is manhole free of excessive roots? Is manhole free of excessive sand? C Is manhole's extended vent screened? Are vents free of submergence? Are manholes free of bypass structures or pipes? Comment: 4 - "_� Manhole ,4� 0 ,-f 0- Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE Page: 9 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 08/10/2015 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Is manhole accessible? ❑ ❑ El El # Is manhole cover/vent above grade? 1 Is the manhole free of visible signs of overflow? ❑ El ❑ ❑ Is the manhole free of sinkholes and depressions? ❑ El El ❑ Is manhole cover present? ❑ ❑ # Is manhole properly seated? ❑ ❑ # Is manhole in good condition?---- ❑ ❑ ❑ # Is invert in good condition? �` ❑ Is line free -flowing and unrestricted in manhole? ❑ El 0 ❑ Is manhole free of excessive amounts of grease? El EJ ❑ ❑ Is manhole free of excessive roots? , ❑ ❑ ❑ Is manhole free of excessive sand? ❑ El ❑ Is manhole's extended vent screened? ❑ Are vents free of submergence? / ❑ ❑ El El e manholes free of bypass structures or pipes? / /—� i/ El El El D r� Comment: Pager 10 Compliance Inspection Report HIV Permit: WQCS00091 Effective: 04/01/13 Expiration: 03/31/18 Owner: Town of Spruce Pine SOC. Effective: - Expiration: Facility: Spruce Pine Collection System County: Mitchell PO Box 189 Region: Asheville Spruce Pine NC 28777 Contact Person:. Richard Canipe Title: Town Manager Phone: 828-765-3000 Directions to Facility: System Classifications: CS2, Primary ORC: Secondary ORC(s): On -Site Representative(s): Certification: Related Permits: NCO021423 Town of Spruce Pine - Spruce Pine WWTP Inspection Date: 11/21/2014 EntryTime: 10:OOAM Primary Inspector: Linda S Wiggs Secondary Inspector(s): Phone: Exit Time: 02:OOPM Phone: 828-296-4500 6d.4653 Reason for Inspection:. Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Collection system management and operation , Facility Status: ❑ Compliant E Not Compliant Question Areas: Miscellaneous Questions Performance Standards Operation & Maint Reqmts �. Records Monitoring & Rpting Regmts Inspections Pump Station Manhole Lines (See attachment summary) Page: 1 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine' Inspection Date: 11/21/2014 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: Performance Standards: Permit Condition # I. 4. FOG education is occurring once a year via text in the water bills. Distribution of educational, material is required twice a year. The Depot PS had been pumped 2 weeks prior; however the PS had a fair amount of grease present. This PS receives several non-residential users; increased attention/actions to these users according to the local Grease Ordinance may be warranted. Permit Condition # I. 5. The CIP is dated through 2015-16; a new CIP covering 3-5 years will need to be developed. Permit Condition # I. 6. The manhole just upstream of the Depot PS has what appeared to be a bypassfine. This line has to be immediately removed or permanently capped. Operation and Maintenance: Permit Condition # II. 1. There is not an ORC designated who possesses a valid certificate of a grade CS-2. The permit requirement for the Permittee to designate an ORC was required by mid- April 2013. An ORC designation form shall be submitted immediately. Permit Condition # II. 8. The line along the south side, of the river between the manhole at TriCounty Oil and the Ball Field needs immediate cleaning. Inspection of manholes revealed 4" of sediment (sand, gravel) present. Where this sediment is coming from also needs to be evaluated and remediated. -,9-Q� Records/Inspections: Permit -Conditions # III. 1. # V. 1. Record keeping needs to be improved. The inspector sent.an email on December 11, 2014 to Mr. Canipe containing collection system operator logs that should be considered for use to assist in improving the records requirements. The map also needs to be updated. Page: 2 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/21/2014 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Performance Standards Yes No NA NE Is Public Education Program for grease established and documented? 0 ❑ ❑ ❑ What educational tools are used? Text within the water bill is sent annually. Need to send FOG information twice a year. Consider using forms sent via email on 12/11/2014 to document FOG education. Also consider using a flyer insert or something more th t'text to catch�us�s attention. Is Sewer Use Ordinance/Lega�ty available? ❑ ❑ ❑ Does it appear that the Sewer Use Ordinance is enforced? 0 ❑ ❑ ❑ Is Grease Trap Ordinance available? M ❑ ❑ ❑ Is Septic Tank Ordinance available (as applicable, i.e. annexation) ❑ ❑ ❑ List enforcement actions by permittee, if any, in the last 12 months Has an acceptable Capital Improvement Plan (CIP) been implemented? ❑ ❑ ❑ Does CIP address short term needs and long term \"master plan\" concepts? ❑ ❑ ❑ Does CIP cover three to five year period? M ❑ ❑ ❑ Does CIP include Goal Statement? 0 ❑ ❑ ❑ Does CIP include description of project area? 0 ❑ ❑ El DoeS,CIP include description of existing facilities? M ❑ ❑ ❑ Does CIP include known deficiencies? ❑ ❑ ❑ Does CIP include forecasted future needs? ❑ ❑ ❑ Is CIP designated, only for wastewater collection and treatment? ❑ ❑ ❑ Approximate capital improvement budget for collection system? $828,000.00 Total annual revenue for wastewater collection and treatment? $187,000.00 CIP Comments. The CIP is only until 2015-2016. A new one will need to be developed through the next 3-5 years. Grease Trap inspections and FOG educationin the vicinity of Depot PS needs to be increased. Is system free of known points of bypass? ❑ 0 ❑ ❑ If no, describe type of bypass and location A bypass line was found during the inspection of the manhole just upstream of the Depot PS. This bypass will have to be removed immediately. Is a 24-hour notification sign posted at ALL pump stations? M ❑ ❑ ❑ # Does the sign include: Instructions for notification? M ❑ ❑ ❑ Pump station identifier? K ❑ ❑ ❑ 24-hour contact numbers 0 ❑ ❑ ❑ If no,, list deficient pump stations # Do ALL pump stations have an "auto polling" feature/SCADA? ❑ 0 ❑ ❑ Number of pump stations 14 Page: 3 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/21/2014 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Number of pump stations that have SCADA- o Number of pump stations that have simple telemetry Number of pump stations that have only audible and visual alarms Number of pump stations that do not meet permit requirements # Does the permittee have a root control program? # If yes, date implemented? Describe: The town has a jetter with a cutter head. Comment: Inspections Are maintenance records for sewer lines available? Are records available that, document pump station inspections? Are SCADA or telemetry equipped pump stations inspected at least once a week? Are non-SCADA/telemetry equipped pump stations inspected every day? Are records available that document citizen complaints? # Do you have a system to conduct an annual observation of entire system? #'Has there been an observation of remote areas in the last year? Are records available that document inspections of high-priority'Iines? Has there been visual inspections of high -priority lines in last six months? Comment: All PS are inspected daily. Operation & Maintenance Requirements Are all log books available? Does supervisor review all log books on a regular basis? Does the supervisor have plans to address documented short-term problem areas? What is the schedule for reviewing. inspection, maintenance, & operations logs and problem areas? As needed, regularly. Are maintenance records for equipment available? Is a schedule maintained for testing emergency/standby equipment? What is the schedule for testing emergency/standby equipment? Do pump station logs include: Inside and outside cleaning and debris removal? Inspecting and exercising all valves? Inspecting and lubricating pumps and other equipment? Inspecting alarms, telemetry and auxiliary equipment? Is there at least one spare pump for each pump station w/o pump reliability? Are maintenance records for right-of-ways available? Are right-of-ways currently accessible in the event of an emergency? ■❑❑❑ Yes No NA NE ❑ ❑ ❑ ■❑❑❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ■❑❑❑ ❑ ❑ M ❑ ■❑❑❑ ■❑❑❑ Yes No NA NE ■❑❑❑ ■❑❑❑ ■❑❑❑' ❑ ❑ ❑ ❑ ❑ ❑ ■❑❑❑ ■❑❑❑ ■❑❑❑ ❑❑❑■ ■❑❑❑ Page: 4 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/21/2014 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Are system cleaning records available? 0 ❑ ❑ ❑ Has at least 10%of system -been cleaned annually? 0 ❑ ❑ ❑ What areas are scheduled for cleaning in the next 12 months? Line along the river has signficant sediment buildup.. ROW �Yd Exposed line Is a Spill Response Action Plan available? E ❑ ❑ ❑ Does the plan include: 24-hour contact numbers ❑ ❑ ❑ Response time Equipment list and spare parts inventory Access to cleaning equipment Access to construction crews, contractors, and/or engineers Source of emergency funds Site sanitation and cleanup materials Post-overflow/spill ,assessment Is a Spill Response Action Plan available for all personnel? l Is the spare parts inventory adequate? q' Comment: Emergency/After hour phone numbers need to be added to SRAP. Records Are adequate records of all SSOs, spills and complaints available? Are records of SSOs that are under the reportable threshold available? Do spill records indicate repeated overflows (2 or more in 12 months) at same location? If yes, is there a corrective action plan? Is a map of the system available? Does the map'include: Pipe sizes Pipe materials Pipe location Flow direction Approximate pipe age Number of service taps Pump stations and capacity If no, what percent is complete? ■,❑❑❑ • ❑ ❑ ❑ • ❑ ❑ ❑ N ❑ ❑ ❑ ■❑❑❑ ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑ • ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑■❑❑ ■❑❑❑ ■❑❑❑ List any modifications and extensions that need to be added to the map -, % � v � Map needs to be updated. NY' C ii�� /*_ # Does the permittee have a copy of their permit? 0 ❑ ❑ ❑ Comment: Page: 5 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/21/2014 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Monitor'in-q and Reporting Requirements Yes No NA NE Are copies of required press releases and distribution lists available? ❑ ❑ ❑ Are public notices and proof of publication available? M ❑ ❑ # Is an annual report being prepared in accordance with G.S. 143-215.1 C? ❑ ❑ ❑ -# Is permittee compliant with all compliance schedules in the permits? ❑ fi ❑ If no, which one(s)? Comment: TRICOUNTY MH - MH acrol Manhole Is manhole accessible? # Is manhole cover/vent above grade? Is the manhole free of visible signs of overflow? Is the manhole free of sinkholes and depressions? Is manhole cover present? # Is manhole properly seated? # Is manhole in good condition? # Is invert in good condition? Is line free -flowing and unrestricted in manhole? Is manhole free of excessive amounts of grease? Is manhole free of excessive roots? Is manhole free of excessive sand? Is manhole's extended vent screened? Are vents free of submergence? Are manholes free of bypass structures or pipes? Comment: Excessive sand/gravel 4" deep. Evidence of surging. DEPOT PS - Pump Station Pump station type Are pump station logs available? Is it accessible in all weather conditions? # Is general housekeeping acceptable? Are all pumps present? Are all pumps operable? Are wet wells free of excessive debris? Yes No NA NE ❑ ❑ ❑ ❑ M ❑ ❑ ■❑❑❑ ■❑❑❑ 0❑❑❑ ❑ ❑ ❑ ■❑❑❑ ❑ ❑ ❑ ■❑❑❑ ❑ ❑ ❑ ❑ M ❑ ❑ ❑ ❑ ❑ ❑❑■❑ ❑ ❑ ❑ Yes No NA NE Duplex ❑ ❑ ❑ ■❑❑❑ ■❑❑❑ ❑ ❑ ❑ ❑ ❑ ❑ 0❑❑❑ Page: 6 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/2112014 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Are upstream manholes free of excessive debris/signs of overflow? ❑ M ❑ ❑ Are floats%controls for pump's/alarms operable? ❑ ❑ ❑ Is "auto polling," feature/SCADA present? ❑ ❑ 0 El Is "auto polling" feature/SCADA operational? ❑ ❑ M ❑ Is simple telemetry present? 0 ❑ ❑ ❑ Is simple telemetry operational? M ❑ ❑ ❑ Are audio and visual alarms present? 0 ❑ ❑ ❑ Are audio and visual alarms operable? ❑ ❑ ❑ Is the Pump station inspected as required? 0 ❑ T❑ ❑ Are backflow devices in place? 0 ❑ ❑ ❑ Are backflow devices operable? ❑ ❑ ❑ M Are air relief valves in place? N ❑ ❑ ❑ Are air relief valves operable? ❑ ❑ ❑ # Is an emergency generator available?M ❑ - ❑ ❑ Can the emergency generator run the pumps? M ❑ ❑ ❑ Is the pump station equipped for quick hook-up? ❑ 0 ❑ ❑ Is the generator operable? ❑ ❑ 0 ❑ #.Is fuel in tank and sufficient? ❑ ❑ 0 El Is the generator inspected according to their schedule? M ❑ ❑ ❑ 'Is a 24-hour notification sign posted? M ❑ ❑ ❑ Does it include: Instructions for notification? M ❑ ❑ ❑ Pump station identifier? M ❑ ❑, ❑ Emergency phone number M ❑ ❑ ❑ Is public access limited? 0❑ ❑ ❑ Is pump station free of overflow piping? 0 ❑ ❑ ❑ Is the pump station free of signs of overflow? M ❑ ❑ ❑ Are run times comparable for multiple pumps? Comment: This is a very old PS. It had -been pumped 2 weeks ago and there was a moderate amount of grease stil present. Grease Education in this area needs to be increased. The upstream MH has a bypass line. By design you can't see all'of the components of this PS. ALONG N. TOE RVR - Sout Lines/Right-of-Ways/Aerie) Lines Is right-of-way accessible for emergency? Is right-of-way free of sinkholes or depressions? Is line/right-of-way free of evidence of leakage? # Are there areas of exposed line? Yes No NA NE ■❑❑❑ Page: 7 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/21/2014 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine # Is any exposed line constructed of ductile iron or other approved material? ❑ ❑ ❑ Are water crossing and supports in good condition? ❑ ❑ 0 ❑ # Is right-of-way free of non -utility motorized traffic? 0 ❑ ❑ ❑ Is line free of visible damage? 0❑ ❑ ❑ # Are there siphons in this system? ❑ ❑ 0 ❑ If yes, are they maintained and documented? Comment: As indicated by MH inspections this line appears to have significant sediment impacts which ����/" would cause capacity concerns. The ROW was not clear, it had brush and sapplings growing. A truck could get through though.. DEPOT PS MH - MH just up Manhole Yes o NA NE Is manhole accessible? ❑ ❑ ❑ # Is manhole cover/vent above grade? 0 ❑ ❑ ❑ Is the manhole free of visible signs of overflow? 0 ❑ ❑ ❑ Is the manhole free of sinkholes and depressions? ❑ ❑ ❑ Is manhole cover present? M ❑ ❑ ❑ # Is manhole properly seated? ❑ ❑ ❑ r # Is manhole in good condition? ❑ 0 ❑ ❑ # Is invert in good condition? ❑ ❑ ❑ Is line free -flowing and unrestricted in manhole? ❑ ❑ Is manhole free of excessive amounts of grease? ❑ ❑ ❑ Is manhole free of excessive roots? M ❑ ❑ ❑ Is manhole free of excessive sand? ❑ ❑ ❑ Is manhole's extended vent screened? ❑ ❑ ❑ Are vents free of submergence? ❑ ❑ 0 ❑ Are manholes free of bypass structu es or pipes? / ���G\Jf ❑ W-❑ ❑ r !/ • V Comment; CS�y� BALLPARK MH - MH upstr( Manhole Is manhole accessible? # Is manhole cover/vent above grade? Is the manhole free of visible signs of overflow? Is the manhole free of sinkholes and depressions? Is manhole cover present? # Is manhole properly seated? # Is manhole in good condition? # Is invert in good condition? Yes No NA NE ■❑❑❑ ■❑❑❑ ■❑❑❑ ❑ ❑ ❑ ■❑❑❑ Page: 8 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/21/2014 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Is line free -flowing and unrestricted in manhole? N ❑ ❑ ❑ Is manhole free of excessive amounts of grease? 0 ❑ ❑ ❑ Is manhole free of excessive roots? M ❑ ❑ Is manhole free of excessive sand? ❑ ❑ ❑ Is manhole's extended vent screened? ❑ ❑ N❑ Are vents free of submergence? ❑ ❑ NO Are manholes free of bypass structures or pipes? N ❑ ❑ ❑ Comment: Excessive amount of sand/ -gravel 4". Evidence of surging. Are storm drains tied into this line? i I 0 Page: 9 0 Compliance Inspection Report -011 Permit: WQCS00091 Effective: 04/01/13 Expiration: 03/31/18 Owner: Town of Spruce Pine SOC: Effective: Expiration: Facility: Spruce Pine Collection System County: Mitchell PO Box 189 Region: Asheville Spruce Pine NC 28777 Contact Person: Richard Canipe Title: Town Manager Phone: 828-765-3000 Directions to Facility: System'Classifications: CS2, Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: NCO021423 Town of Spruce Pine - Spruce Pine WWTP Inspection Date: 11/14/2014 EntryTime: 10:OOAM Exit Time: 02:OOPM Primary Inspector: _ Linda S Wiggs - — Plione: 828-296-4500 Ext.4653 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Collection system management and operation Facility Status: ❑ Compliant ❑ Not Compliant Question'Areas: Miscellaneous Questions Performance Standards Operation & Maint Reqmts Records Monitoring & Rpting Reqmts Inspections - Pump Station ' Manhole - Lines (See attachment summary) Page: 1 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: ' 11/14/2014 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: c� Page: 2 Permit: VVQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/14/2014 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Performance Standards Yes No NA NE ,J„ Is Public Education Program for grease established and documented? ❑ ❑ ❑ What educational tools are -used? Is Sewer Use Ordinance/Legal Authority available? ❑ ❑, ❑ ❑ Does it appear that the Sewer Use Ordinance is enforced? ❑ ❑ ❑ ❑ Is Grease Trap Ordinance available? v) S" 1 g-ly7 A;laL1D t �'��� ❑ ❑ ❑ ❑ .� Is Septic Tank Ordinance available (as applicable, i.e. annexation) ❑ ❑ ❑ ❑ List enforcement actions by permittee, if any, in the last 12 months Has an acceptable Capital Improvement Plan (CIP) been implemented? ❑ ❑ ❑ ❑ Does CIP address short term needs and long term \"master plan\" concepts? C ❑ ❑ ❑ ❑ � l Does CIP cover three to five year period? v ❑ ❑ ❑ ❑ Does CIP include Goal Statement? N" ❑ ❑ ❑ ❑ Does CIP include description of project area? (Y A i ❑ ❑ El El Does CIP include description of existing facilities? "I � � � ❑ ❑ ❑ ❑ Does CIP include known deficiencies? (-�' will ct,�' - ❑ ❑ ❑ ❑ Does CIP include forecasted future needs? �rq M c �1 ❑ ❑ ❑ ❑ Is CIP designated only for wastewater collection and treatment?❑/ ❑ ❑ ❑ 1 Approximate capital improvement budget for collection system?99 ­J .Total annual revenue for wastewater collection and treatment? CIP Comments Is system free of known points of bypass? �,� J���� ❑ ❑ ❑ ❑ If no, describe type of bypass and location Is a 24-hour notification sign posted at ALL pump stations? # Does the sign include: Instructions for notification? Pump station identifier? 24-hour contact numbers If no, list deficient pump stations # Do ALL pump stations have an "auto polling" feature/SCADA? Number of pump stations . Number of pump stations that have SCADA Q Number of pump stations that have simple telemetry Number of pump stations that have only audible and visual alarms Number of pump stations that do not meet permit requirements # Does the permittee have a root control program? 1111 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ly� — ❑ ❑ ❑ ❑ Page: 3 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine D q r ra.'1 / Inspection Date: 11/14/2014 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine # If yes, date implemented? Describe: Comment: Inspections Are maintenance records for sewer lines available? Are records available that document pump station inspections? y Are SCADA or.telemetry equipped pump stations inspected at least once a week? Are non-SCADA/telemetry equipped pump stations inspected every day? Are records available that document citizen complaints? # Do you have a system to conduct an annual observation of entire system? # Has there been an observation of remote areas in the last year? Are records available that document inspections of high -priority lines? Has there been visual inspections of high -priority lines in last six months? Comment: Operation & Maintenance Requirements Are all log books available? Does supervisor review all log books on a regular basis? Does thei'supervisor have plans to address documented short-term problem areas? What is the schedule for reviewing inspection, maintenance, & operations logs and problem areas? Are maintenance records for equipment available? Is a schedule maintained for testing emergency/standby equipment? What is the schedule for testing emergency/standby equipment? Do pump station logs include: Inside and outside cleaning and debris removal? Inspecting and exercising all valves? Inspecting and lubricating pumps and other equipment? Inspecting alarms, telemetry and auxiliary equipment? Is there at least one spare pump for each pump station w/o pump reliability? Are maintenance records for right-of-ways available? Are right-of-ways currently accessible in the event of an emergency? Are system cleaning records available? Has at least 10% of system been cleaned annually? What areas are scheduled for cleaning in the next 12 months? Is a Spill Response Action'Plan available? Does the plan. include: 24-hour contact numbers Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ 1111 ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Page: 4 / r- Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/14/2014 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Response time ail�`_� ❑ El❑ El Equipment list and spare parts inventory s r� ❑ ❑ ❑ ❑ Access to cleaning equipment ❑ ❑ ❑ ❑ Access to construction crews, contractors, and/or. engineers ❑ ❑ ❑ ❑ Source of emergency funds ❑ ❑ ❑ ❑ Site sanitation and, cleanup materials ❑ ❑ ❑ Post-overflow/spill assessment ❑ ❑ ❑ ❑ Is a Spill Response Action Plan available for all personnel? ❑ ❑ ❑ ❑ Is the spare parts inventory adequate? ❑ ❑ ❑ ❑ Comment: Records Yes No NA NE Are adequate records of all'SSOs, spills and complaints available? ❑ ❑ ❑ ❑ Are records of SSOs that are under the reportable threshold available? ❑ ❑. ❑ ❑ Do spill records indicate repeated overflows (2 or more in 12 months) at same location? ❑ ❑ ❑ ❑ If yes, is there a corrective action plan? ❑ ❑ ❑ ❑ Is a map of the system available? ❑ ❑ ❑ ❑ Does the map include: -Pipe sizes- — - - - -- - - _ ❑ ❑ ❑ ❑ Pipe materials ❑ ❑ ❑ ❑ Pipe location ❑ ❑ ❑ ❑ Flow direction ❑ ❑ ❑. ❑ Approximate pipe age ❑ El El El Number of'service taps ❑ ❑ ❑ ❑ Pump stations and capacity ❑ ❑ 1111 If no, what percent is complete? List any modifications and extensions that need to be added to the map s # Does the permittee have a copy of their permit? - ❑ ❑ ❑ ❑ Comment: Monitoring and Reporting Requirements Yes No NA NE Are copies of required press releases and distribution lists available? ❑ ❑. ❑ ❑ Are public notices and proof of publication available? ❑ ❑ ❑ ❑ - # Is an annual report being prepared in accordance with G.S. 143-215.1 C? (,.!'/� ❑ ❑ ❑ ❑ # Is permittee compliant with all compliance schedules in the permits? ❑ ❑ ❑ ❑ If no, which one(s)? Comment: Page: 5 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/14/2014 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Pump Station Pump station type Are pump station logs available? G, Is it accessible in all weather conditions? # Is general housekeeping acceptable? Are all pumps present? Are all pumps operable? Are wet wells free of excessive debris? Are upstream manholes free of excessive debris/signs of overflow? Are floats/controls for pumps/alarms operable? Is "auto polling" feature/SCADA present?�V Is "auto polling" feature/SCADA operational? Is simple telemetry present? G: Is simple telemetry operational? Are audio and visual alarms present? Are audio and visual alarms operable? /Y _ Is the Pump station inspected as required? Are backflow devices in place? Are backflow devices operable? Are air relief valves in place? Are air relief valves operable? # Is an emergency generator available? ' Can the emergency generator. run the pumps? Is the pump station equipped for quick hook-up? Is the generator operable? # Is fuel in tank and sufficient? Is the generator inspected according to their schedule? Is a 24-hour notification sign posted? Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑❑❑ ❑ ❑ ❑ ❑ ❑❑❑❑ ❑❑❑El' ❑ ❑ ❑ ❑ ❑❑❑❑ ❑ ❑ ❑ ❑ Does it include: Instructions for notification? T� ❑ ❑ ❑ ❑ Pump station identifier? ❑ ❑ ❑ ❑ Emergency phone number ❑ ❑ ❑ ❑ Is public access limited? ❑ ❑ ❑ ❑ Is pump station free of overflow piping? ❑ ❑ ❑ ❑ Is the pump station free of signs of overflow? ❑ ❑ ❑ ❑ Are run times comparable for multiple pumps? Page: 6 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/14/2014 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Comment: MAIN - Lines/Right-of-Ways/Aerie) Lines Is right-of-way accessible'for emergency? Issright-of-way free of sinkholes or depressions? Is line/right-of-way free of evidence of leakage? # Are there areas of exposed line? # Is any exposed line constructed of ductile iron or other approved material? Are water crossing and supports in good condition? # Is right-of-way free of non -utility motorized traffic? Is line free of visible damage? # Are there siphons in this system? If yes, are they maintained and documented? Comment: BIGGERSTAF Manhole Is manhole accessible? his #"Is manhole -cover/ventfabove grade? G` Is the manhole free of visible signs of overflow? V Is the manhole free of sinkholes and depressions?? Is manhole cover present? �! #.Is manhole properly seated? # Is manhole'in good condition? # Is invert in good condition? Is line free -flowing and unrestricted in manhole? Is manhole free of excessive amounts of grease? ^ Is manhole free of excessive roots? Is manhole free of excessive sand? Is manhole's extended vent screened? Are vents fre of sub ergence? �1 Are manhol s free Ibypass structures or pipes? ,Corriment: DX AP Ip o) rir-rn l- e Yes No NA NE ❑ ❑ ❑ ❑ El ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑. ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Page: 7 0 44 je NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Charles Wakild, P. E. Dee Freeman Governor Director►,. o_.A .;. ___ Secretary December 5th 2012 Richard Canipe, Town Manager Town of Spruce Pine PO Box 189 Spruce Pine, NC 28777 Subject: Permit No. WQCS00091 Town of Spruce Pine Spruce Pine Collection System Mitchell County Dear Mr. Canipe: P D E FDE1 2012 LwArER �'UALlTI' sECTICN ASNEVILLERECIr�yALCFrICE ; ��:« a-_,., ,.....�c: _ ...._......,....., :.�._.�.,_.,.. , .......�, ...::.w.:��. In accordance with your application received November 30th, 2012, we are forwarding herewith Permit No. WQCS00091, dated December 5th, 2012, to the Town of Spruce Pine for the operation and maintenance of the subject wastewater collection system. This permit shall be effective from April 15t, 2013 until March 315 2018 and shall be'subject to the conditions and limitations specified herein. It is your responsibility to thoroughly review this permit. Please pay particular attention to the monitoring and reporting requirements in this permit and any compliance schedules shown in bold. For purposes of permitting, the collection system is considered to be any existing or newly installed system extension up to the wastewater treatment facility property or point of connection with a separately owned sewer system. The collection system is considered all gravity lines, pump stations, force mains, low pressure sewer systems, STEP systems, vacuum systems, etc. and associated piping, valves and appurtenances that help to collect, manage and transport wastewater to a wastewater treatment plant under the Permittee's ownership or maintained and operated by the Permittee through a perpetual legal agreement. Satellite systems- are systems -tributary--to- the- Permittee's collection -system but -those _collection -systems are _not-owned_or maintained by the Permittee. The system description provided on Page 1 of this permit is meant to provide a general idea about the size of the system and may not be all inclusive of the collection system at the time of permit issuance or afterward. A release of wastewater from the wastewater collection system is referred to herein as a Sanitary Sewer Overflow (SSO). The evaluation of enforcement options after an SSO will be determined considering the criteria listed in condition I(2)(a) and I(2)(b)-of the permit and all other relevant 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 One Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 Phone: 919-807-63001 FAX: 919-807-6492 North Carolina Intemet: www.ncwaterouality.org NaharallyAn Equal Opportunity 1 Affirmative Action Employer December 5`°, 2012 Page 2 of 3 information available or requested of the Permittee. Compliance with all conditions of the permit as well as all statutes and regulations pertaining . to the collection system must be maintained or appropriate enforcement actions may be taken as noted in Condition VI(2). A.reportable SSO is an SSO greater. than 1,000 gallons to the ground or an SSO of any amount that reaches surface water (including through ditches, storm drains, etc.) Below is the procedure to use for reporting SSOs to the Division: 1. Report by telephone to a Division of Water Quality (DWQ) staff member (not email, facsimile, or voicemail) at your regional DWQ office during regular business hours (Monday to Friday, 8AM to 5PM) as soon as possible, but in no case more than 24 hours after the SSO is known or discovered. To report outside of regular business hours, call (800) 858-0368. 2. Follow up the verbal report by sending a completed written report on the most current Division approved form within five days. To provide a uniform method for all systems covered under this permit and to provide useful and consistent information pertaining to SSOs, please utilize form CS-SSO .consisting of two parts. Part I serves to provide to the Division the required information that has always been necessary. Part II serves as an area to provide a justification for the spill, as optional under Condition I(2) of your permit. Form CS-SSO can be downloaded from the SSO Reporting area at http://portal.ncdenr.org/web/wq/swp/ps/es/ssoreport. An NOV, civil penalty, and/or a moratorium on the addition of waste to the system may be issued if adequate justification for an SSO is NOT submitted to the regional office. In order to submit a claim, for justification of an SSO, you must use Form CS-SSO with additional documentation as necessary. DWQ staff will review the justification claim and determine if enforcement action is appropriate. Please be advised that the'information needed to justify a spill is very comprehensive. Begin using this form immediately to report SSOs from the collection system. Continue to use our old form for reporting bypasses at the wastewater treatment plant until further notice. The time frame for submittal of both Part I and Part II, if pertinent, is five days. Failure to abide by the conditions in this permit may subject the Pernnittee to enforcement action. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty days following the receipt of this permit. This request must be in the form of_a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. December 5"', 2012 Page 3 of 3 If you have questions regarding compliance contact your regional office or the Pretreatment, Emergency Response and Collection Systems Unit of the North Carolina Division of Water Quality at (919) 807-6300. If you need additional information concerning this permit, please contact Michael Leggett at (919) 807-6312. Sincerely, for Charles Wakild, P.E., Director Division of Water Quality by Deborah Gore, Supervisor Pretreatment, Emergency Response, Collection System Unit enclosure: Permit No. WQCS00091 cc: Mitchell County Health Department Ashe�e Regional OTfic_ e, Surface: Water-Protection-Section� Water Quality Central FilesQCS00091 Steve Reid, NPDES — Compliance & Expedited Permitting Unit (electronic) PERCS Files (electronic) NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH SYSTEM -WIDE WASTEWATER COLLECTION SYSTEM PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO THE Town of Spruce Pine, Mitchell County FOR THE operation and maintenance of a wastewater collection system consisting of, at the time of permit issuance, approximately 35 miles of gravity sewer, approximately 15 miles of force main, 14 duplex pump stations, and all associated piping, valves, and appurtenances required to make a complete and operational wastewater collection system to serve .the Town of Spruce Pine and any deemed permitted satellite communities pursuant to' the application received November 301h, 2012, and the additional information and -in conformity with the documents referenced therein and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the April 1st, 2013 until March 31st, 2018, and shall be subject to the following specified conditions and limitations: I. PERFORMANCE STANDARDS 1. The sewage and wastewater collected by this system shall be treated in the Town of Spruce Pine Wastewater Treatment Facility (NC0021423) prior to being disposed into the receiving stream. This collection system permit will be referenced upon renewal or modification of your NPDES permit(s). _2_ The _wastewater _collection . system _shall be _ effectively _managed, maintained and_ operated at all times so that there is no SSO to land or surface waters, nor any contamination of groundwater. In the event that the wastewater collection system fails to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective actions, including actions that may be required by the Division of Water Quality (Division); such as the construction of additional or replacement sewer lines and/or equipment. The Director may take enforcement action against the Permittee for SSOs that must be reported to the Division as stipulated in Condition IV(2). This includes SSOs that were caused by severe natural conditions or exceptional events unless the Permittee demonstrates through properly signed, contemporaneous operating logs, or other relevant evidence that: a. The SSO was caused by severe natural conditions; there were no feasible alternatives to the. SSO, such as the use of auxiliary treatment facilities, retention of untreated wastewater, reduction of inflow and infiltration, use of adequate back-up equipment, or an increase in the capacity of the system. This provision is not satisfied if, in the exercise of reasonable engineering judgment, the Permittee should have installed auxiliary or additional collection system components, wastewater retention or treatment facilities, adequate back-up equipment or should have reduced inflow and infiltration; or b. The SSO was exceptional, unintentional, temporary and caused by factors beyond the reasonable control of the Permittee; the SSO could not have been prevented by the exercise of reasonable control, such as proper management, operation and maintenance; adequate treatment facilities or collection system facilities or components (e.g._, adequately enlarging treatment or collection facilities to accommodate growth or adequately controlling and preventing infiltration and inflow); preventive maintenance; or installation of adequate back- up equipment; The Permittee can submit a claim to the Division Regional Office that the SSO meets the criteria of this condition. The Permittee has the option of submitting this claim along with the spill report required by Condition IV(2) (i.e., within five days) in order to be considered for immunity from enforcement action. Form CS-SSO Part II, or most current Division approved form, shall be used for any claims. The Permittee has the burden of proof that the above criteria have been met. 3. The Permittee shall establish by ordinance its legal authority to require new sewers be properly constructed;. to ensure proper inspection and testing of sewer mains and service laterals; to address flows from satellite systems and to take enforcement action as required by Condition 1(4). 4. The Permittee shall develop and implement an educational fats, oils and grease program that shall include at least bi-annual distribution of educational material targeted at both residential and non-residential users. The Permittee shall also develop and implement an enforceable fats, oils and grease program for non-residential users under which the Permittee can take enforcement against users who have not properly installed, operated and maintained grease traps or grease interceptors as directed or otherwise violated the terms of the local ordinance pertaining to fats, oils and grease. 5. The Permittee shall adopt and implement a Capital Improvement Plan (CIP) to designate -- - - - - funding for reinvestment into the wastewater collection system infrastructure. The-CIP should address the short-term needs and long-term "master plan" concepts. The CIP should typically' cover a three to five year period and include a goal statement, description of the project area, description of the existing facilities, known deficiencies (over a reasonable period) and forecasted future needs. Cost analysis is integral to the CIP. 6. Existing overflow piping f -wand pump stations, excluding piping to approved equalization structures, known or discovered after permit issuance shall be immediately removed or permanently capped. Plugged emergency pumping connections are allowable for portable pumping or rerouting without • intentionally bypassing the wastewater treatment facility. 7. The Permittee shall maintain a contingency plan for pump failure at each pump station. If one of the pumps in a pump station containing multiple pumps fails, the process of repairing or replacing the pump shall be initiated immediately and the new parts or pump shall be installed as soon as possible. If the pump in a simplex pump station fails, it shall be replaced immediately. 8. Each pump station shall be clearly and conspicuously posted with a pump station identifier and an emergency contact telephone number at which an individual who can initiate or perform emergency service for the wastewater collection system 24 hours per day, seven days per week can be contacted. This emergency contact telephone number shall be coupled with instructions that the emergency contact should be called if the visual alarm illuminates, if the audible alarm sounds, or if an emergency is apparent. 9. Pump station sites, equipment and components shall have restricted access, per 15A NCAC 02T .305(h)(4). 10. Pump stations that do not employ an automatic polling feature (i.e. routine contact with pump stations from a central location to check operational status of the communication system) shall have both audible and visual high water alarms. The alarms shall be weather-proof and placed -in a clear and conspicuous location. Permits issued for the construction of pump stations that included high water alarms in the description must maintain the alarms even if simple telemetry (i.e. notification of an alarm condition initiated by the pump station control feature) is installed. 11. For all newly constructed, modified and rehabilitated pump stations, all equipment and components located within the pump station shall be corrosion -resistant- and components in close proximity of the pump station shall be sealed within a corrosion - resistant coating or encasement. 12. All construction and rehabilitation of the wastewater collection system (i.e., permitted or deemed permitted) shall be scheduled to minimize the interruption of service by the existing utilities. Construction and rehabilitation shall not result in the violation of Condition (1)(2) of this permit. II. OPERATION AND MAINTENANCE REQUIREMENTS Upon classification of the collection system by the Water Pollution Control System Operators Certification Commission (WPCSOCC), the Permittee shall designate and employ a"certified operator to be in responsible charge (ORC) and one or more 'certified operator(s) to be back-up ORC(s) of the facilities in accordance with 15A NCAC 8G .0201. The ORC shall visit the system within 24 hours of knowledge of a bypass, spill, or overflow of wastewater from the system, unless visited by the Back -Up ORC, and shall comply with all other conditions of 15A NCAC 8G .0204. The Permittee shall designate one ORC who possess a valid certificate of the type and grade at least equivalent to the type and grade of the Town of Spruce Pine's system with 120 calendar days of the renewal date of this permit. The Asheville Regional Office should be notified in writing within 30 days of this designation to show compliance with this condition. 2. The Permittee shall develop and adhere to a schedule for reviewing all inspection, maintenance, operational and complaint logs. If the review process results in the identification of any recurring problem in the wastewater collection system that cannot be resolved in a short time period, the Permittee shall establish a plan for. addressing the problem(s). 3. ^ The Permittee shall develop and adhere to a schedule for testing emergency and standby equipment. 4. The Permittee shall develop and implement a routine pump station inspection and maintenance program, which shall include, but not be limited to, the following maintenance activities: a. Cleaning and removing debris from the pump station structure, outside perimeter, and wet well; b. Inspecting and exercising all valves; c. Inspecting and lubricating pumps and other mechanical equipment according to the manufacturer's recommendations; and d. Verifying the proper operation of the alarms, telemetry system and auxiliary equipment. 5. For each pump station without pump reliability (i.e. simplex pump stations serving more than a single building or pump stations not capable of pumping at a rate of 2.5 times the average daily flow rate with the largest pump out of service), at least one fully operational spare pump capable of pumping peak flow shall be maintained on hand. 6. The Permittee shall maintain on hand at least two percent of the number of pumps installed, but no less than two pumps, that discharge to a pressure sewer and serve a single building, unless the Permittee has the ability to purchase and install a replacement pump within 24 hours of first knowledge of the simplex pump failure or within the storage capacity provided in any sewer line extension permit. 7. Rights -of -way and/or easements shall be properly maintained to allow accessibility to the wastewater collection system unless the Permittee can demonstrate the ability to gain temporary access in an emergency situation where existing land -use conditions do not allow the establishment and maintenance of permanent access. In this case, the Permittee shall continue to observe the lines visually, utilize remote inspection methods (e.g. CCTV) and use the opportunity of drier conditions to perform further inspections and necessary maintenance. 8. The Permittee shall assess cleaning needs, and develop and implement a program for appropriately cleaning, whether by hydraulic or mechanical methods, all sewer lines. At least 10 percent of the wastewater collection system, selected at the discretion of the ORC, shall be cleaned each year. Preventative cleaning is not required for sewer lines less than five years old unless inspection otherwise reveals the need for cleaning or cleaning is required by a sewer line extension permit. 9. Adequate measures shall be taken. -to contain and properly dispose of materials associated with SSOs. The Permittee shall maintain a Response Action Plan that addresses the following minimum items: a. Contact phone numbers for 24-hour response, including weekends and holidays; b. Response time; c. ' Equipment list and spare parts inventory; d. Access to cleaning equipment; e. Access to construction crews, contractors and/or engineers; f. Source(s) of emergency funds; g. Site sanitation and clean up materials; and h. Post-SSO assessment. 10. The Permittee, or their authorized representative, shall conduct an on -site evaluation for all SSOs as soon as possible, but no more than two hours after first knowledge of the SSO. 11. In the event of an SSO or blockage within the wastewater collection system, the Permittee shall restore the system operation, remove visible solids and paper, sanitize any ground area and restore the surroundings. III. RECORDS 1. Records shall be maintained to document compliance with Conditions 1(4), II(2) - II(4), II(7) - 11(8), IV(3) and V(1) -V(4). Records shall be kept on file for a minimum of three years. 2. The Permittee shall maintain adequate records pertaining to SSOs, and complaints for a minimum of three years. These records shall include, but are not limited to, the following information: a. Date of SSO or complaint; b. Volume of wastewater released as a result of the SSO and/or nature of complaint; c. Location of the SSO and/or complaint; d. Estimated duration of the SSO; e. Individual from the Division who was informed about the SSO and/or complaint, when applicable; f. Final destination of the SSO; g. Corrective actions; h. Known environmental/human health impacts resulting from the SSO; and i. How the SSO was discovered. 3. The Permittee shall maintain an up-to-date, accurate, comprehensive map of its wastewater collection system that also notes the locations where other wastewater collection systems become tributary. If a comprehensive map of the collection system has not been established, a rough sketch shall be drawn. The Permittee shall map approximately 10 percent of its existing collection system each year for the next ten years beginning at the original permit issuance date, or until complete, whichever is sooner. The comprehensive map shall include, but is not limited to: pipe size, pipe material, pipe location, flow direction, approximate pipe age, number of active service taps, and each pump station identification, location and capacity. 4. The Permittee shall maintain records of all of the modifications and extensions to the collection system permitted herein. The Permittee shall maintain a copy of the construction record drawings and specifications for modifications/extensions to the wastewater collection system for the life of the modification/extension. Information concerning the extension shall be incorporated into the map of the wastewater collection system within one year of the completion of construction. The system description contained within this permit shall be updated to include this modification/extension information upon permit renewal. IV. MONITORING AND REPORTING REQUIREMENTS 1. Any monitoring (including, but not necessarily limited to, wastewater flow, groundwater, surface water, soil or plant tissue analyses) deemed necessary by the Division to ensure surface water and groundwater protection will be established, and an acceptable sampling and reporting schedule shall be followed. 2. The Permittee shall verbally report to a Division of Water Quality staff member at the Asheville Regional Office, at telephone number 828-296-4500 as soon as possible, but in no case more than 24 hours following the occurrence or first knowledge of the occurrence of either of the following: a. Any SSO and/or spill over 1,000 gallons; or b. Any SSO and/or spill, regardless of volume, that reaches surface water. Voice mail messages or faxed information shall not be considered as the initial verbal report. SSOs (and other types of spills) occurring outside normal business hours may also be reported to the Division of Emergency Management at* telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Per Condition 1(2), Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 3. The Permittee shall meet the annual reporting and notification requirements provided in North Carolina General Statute §143-215.1 C. V. INSPECTIONS The Permittee or the Permittee's designee shall inspect the wastewater collection system regularly to reduce the risk of malfunctions and deterioration, operator errors, and other issues that may cause or lead to the release of wastes to the environment, threaten human health or create nuisance conditions. The Permittee shall keep an inspection log or summary including, at a minimum, the date and time of inspection, observations made, and any maintenance, repairs, or corrective actions taken by the Permittee. 2. Pump stations without Supervisory Control and Data Acquisition (SCADA) systems or telemetry shall be inspected everyday (i.e. 365 days per year). Pump stations equipped with SCADA systems or telemetry shall be inspected at least once per week. 3. A general observation of the entire collection system shall be performed throughout the course of every year. 4. Inspections of all high priority lines (i.e. aerial line, sub -waterway crossing, line contacting surface waters, siphon, line positioned parallel to stream banks that are subject to eroding in such a manner that may threaten the sewer line, or line designated as high -priority in a permit) shall be performed at least once per every six-month period of time. A list. of high -priority lines is presented as Attachment A and is hereby incorporated into this permit condition. New high priority lines installed or identified after permit issuance are incorporated by reference and subject to this permit condition until permit renewal where they shall be referenced in writing in Attachment A. VI. GENERAL CONDITIONS This permit is not transferable. In the event that the Permittee desires to transfer ownership of the wastewater collection system or there is a name change of the Permittee, a formal permit modification request shall be submitted to the Division. The request shall be accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. Such request will be considered on its merits and may or may not be approved. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute §143-215.6A through §143-215.6C, and a sewer moratorium may be established. 3. The issuance of this permit does not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (i.e., local, state, and federal) having jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, soil erosion and sedimentation control requirements in 15A NCAC Chapter 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 2B .0200 and 15A NCAC 02T .0100 and all applicable North Carolina Occupational Safety and Health Act health and safety standards. 4. The issuance of this permit does not prohibit the Division from reopening and modifying the permit, revoking and reissuing the permit or terminating the permit as allowed by the laws, rules, and regulations contained in 15A NCAC 02T .0100 and North Carolina General Statute §I43-215.1 et. al., or as needed to address changes in federal regulations with respect to the wastewater collection system. 5. The Permittee shall pay the annual fee within thirty (30) days after being billed by the Division. Failure to pay the fee accordingly may cause the Division to initiate action to revoke this permit as specified by 15A NCAC 02T .0110(4). 6. The Permittee shall request renewal of this permit at least six months prior to the expiration of this permit. Upon receipt of the request, the Commission will review the adequacy of the wastewater collection system described therein, and if warranted, will extend the permit for a period of time and under such conditions and limitations, as the Commission may deem appropriate. 7. The Permittee shall notify the Division's Pretreatment, Emergency Response and Collection Systems Unit in writing at 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 of any changes to the name and/or address of the responsible party (i.e. mayor, city/town manager) of the wastewater collection system. 8. Any duly authorized officer, 'employee, or representative of the Division may, upon presentation of credentials, enter and inspect any property, premises or place on or related to the collection system at any reasonable time for the purpose of determining compliance with this permit, may inspect or copy any records that must be maintained under the terms and conditions of this permit, and may obtain samples of wastewater, groundwater, surface water, soil, or plant tissue. Permit issued this the 5th of December, 2012 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION 1, for Charles Wakild, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission by Deborah Gore, Supervisor Pretreatment, Emergency Response, Collection System Unit Permit Number WQCS00091 (Renewal) Town of Spruce Pine, NC Attachment A for Condition V (4) Permit # WQCS00091 High Priority Lines Main interceptor parallel to North Toe River Line from Shannon Drive to WWTP under Toe River Collection line from East side of Town under Toe River 1 uwu of Spruce Pine, NC Attachment A for Condition V (4) Permit # WQCS00091 High Priority Lines Main interceptor parallel to North Toe Diver Line from Shannon Drive to WWTP under Toe River Collection line from East side of Town under Toe River J Town of Spruce Pine Water & Sewer Pump Stations Description Type Pumps HP GPM Mfgr Const Beaver Creek SPS S 2 20 900 Fairbanks . Concrete Prison #1 SPS S 2 50 " 410 Fairbanks Concrete Prison #2 SPS S 2 30 410 Fairbanks Concrete Burleson Hill SPS S 2 30 200 Fairbanks "Concrete Locust Ave SPS S 2 1 100 Fairbanks., Concrete Feldspar-SPS S 2 8 200 Fairbanks Concrete Carters Ridge SPS S 2 50 175 Fairbanks Concrete Pine Branch SPS S 2 3 50 Hydromatic Concrete Sparks Road SPS S 2 3 50 Hydromatic Concrete, Sullins Branch SPS S 2 5 50 Hydromatic Concrete Sunnybrook SPS S 2 11 100 Fairbanks Concrete Duncan Street SPS S 1 2 50 .Fairbanks Concrete Henredon SPS S 2 10 300 Fairbanks .Concrete Mitchell High School SPS S 2 30 90 Keen Concrete u� sPeVC f A �O y� Town of Spruce Pine, North Carolina y�RpH Cp��y October 20, 2016 G. Landon Davidson, P.G., Regional Supervisor Asheville Regional Office NCDEQ 2090 U.S. 70 Highway Swannanoa, NC 28778 RE: NOV-2016-DV-0299 Dear Mr. Davidson: I am writing in response to the above -referenced Notice of Violation. As reported, a pipe failure at the Shannon Drive River Crossing failed, causing a sanitary sewer overflow. Remedial actions included the contracting of Mayland Septic.,Service, Inc., to pump the affected pump station from September 28th through October 3rd. On the afternoon of October 3rd, In -Water Services, Inc., repaired the line in question. I have enclosed copies of both invoices for these services. Thank you for the continued assistance of the NC Division of Environmental Quality. If you need .additional information, please contact me at (828)765-3000. Sincerely, Richard Canipe Manager Town of Spruce Pine RE Division OCT 2 4 2016 Water Quality Regional Operations Asheville Regional Office Post Office Box 189, Spruce Pine, North Carolina 28777-0189 Telephone: (828) 765-3000 Fax: (828) 765-3014 Website: www.sprucepine-nc.gov Mayland Septic Service, Inc. •a 133 Beaver.Creek Road Spruce Pine, NC 28777 Bill To Town of Spruce Pine PO Box 189 Spruce Pine, NC 28777 Invoice Date Invoice # 10/14/2016 2259 P.O. No. Terms Project Quantity Description Rate Amount 9/1 & 9/12 Pump from manhole at Hwy. 226 Grassy Creek 325.00 325.00 9/20 Service Call at Henredon Lift Station 75.00 .75.00 9/29 Pump to unclog pipe at Sewer Plant Clarifier 75.00 75.00 9/28 Pump at Shannon Dr. lift station 150.00 150.00 9/29 Pump at Shannon Dr: lift station 300.00 300.00 9/30 Pump at Shannon Dr. lift station (6PM-IAM) 435.00 435.00 10/I Pump at Shannon.Dr. lift station (8AM-12AM) 795.00 795.00 10/2 Pump at Shannon Dr. lift station (9AM-12AM) 720.00 720.00 10/3 Pump at Shannon Dr. lift station (8AM-1PM) -285.00 285.00 n��iSREfwEI RECourEIVED r OCT 2 4 2016 _ .`Lroual m'. Reglonal Operatlons Asheville Re i TOtaI $3,160.00 3683 southeast Nchool KU .. Greensboro, NC 27406 . 336-674-5757 DATE INVOICE # 10/20/2016 2016-1659 A P.O. NO: TERMS Net 30 DESCRIPTION QTY RATE' AMOUNT ... Contaminated diving ()Aiaste Water):. Sewer Line emergency .. 2,500.00 2,500.00 repairs Travel: 7 75.00 525:00 Sales Tax North Carolina 6.75% 0.00 Total $3,025.00 RECEIVED Division :. Deposit $0.00 OCT-2 4 2016._: Balance. Due $3,025.00 Water Quality Regional Operations .. Asheville Regional Office CERTIFIED MAIL #: 7015 1520 0003 5463 1124 RETURN RECEIPT. REQUESTED October 06, 2016 Richard Canipe Town of Spruce Pine PO Box 189 Spruce Pine, NC 28777 SUBJECT: NOTICE OF VIOLATION Tracking Number: NOV-2016-DV-0299 Sanitary Sewer Overflows - September 2016 Collection System Permit No. WQCS00091 Spruce Pine Collection System Mitchell County bear Permittee: The self -reported Sanitary Sewer Overflow (SSO) 5-Day Report submitted by Town of Spruce Pine indicates violations of permit conditions stipulated in the subject permit and North Carolina G.S. 143-215.1. Violations include failing to effectively manage, maintain, and operate the subject collection system so that there is no SSO to the land. or surface waters and making an outlet to waters of the State for purposes of G.S. 143-215.1(a)(1), for which a permit is required. Specific incident(s) cited in the subject report include the following: Incident Start Duration Number Date (Mins) Location 201601681 9/28/2016 35 Shannon Drive River crossing - PS Force Main Total Vol - Total Surface Vol Water Cause (Gals) (Gals) DWR Action Pipe Failure (Break) 1,000 1,000 Notice of Violation Remedial actions, if not already implemented, should be taken to correct the above noncompliance. Please submit a written response to this Notice of Violation. Your response is to be received by the regional office within 15 business days following receipt of this violation. Please include any additional documentation about this incident(s) in the response. The submittal will be considered in determining whether the Division will assess a civil penalty for the cited violations. State of North Carolina I Environmental Quality I Water Resources ^ 2090 U.S. 70 Highway, Swannanoa, NC 28778 jcj '828-296-4500 1 4 If you have any questions, please do not hesitate to contact Linda Wiggs with the Water Quality Section in the Asheville Regional Office at 8287296-4500 or via email at-linda.wiggs@ncdenr.gov. Sincerely, G. Landon Davidson, P.G., Regional Supervisor Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ Cc: Asheville --Reg not al OfFic- � Central Files, Water Quality Section G:\WR\WOWlitchelftCollection Systems\Spruce Pine Collection SystemlNOV-2016-DV-0299.SS0 9-28-2016.docx State of North Carolina I Environmental Quality I Water Resources 2090 U.S. 70 Highway, Swannanoa, NC 28778 828-296-4500 AL rA RCDENR North Carolina Department of Environment and Natural Resources Pat McCrory John E. Skvarla, III Governor Secretary December 12, 2014 Richard Canipe Town of Spruce Pine PO Box 189 Spruce Pine, NC 28777 Subject: NOTICE OF VIOLATION NOV-2014-DV-0253 Permit No. WQCS00091 Town of Spruce Pine Spruce Pine Collection System Mitchell County . Dear Mr. Canipe: A review has been conducted of Spruce Pine Collection System's self -reported Sanitary Sewer Overflows (SSO's) 5-Day Report submitted by Town of Spruce Pine. This review has shown the subject facility to be in violation of the. requirements found in Collection System Permit WQCS00091 and/or. G.S. 143-215.1(a)(1). The violation that occurred is summarized below. Area Violation Date Description Violation Type Pump Station Riverside Dr. 1019/2014 Sanitary Sewer Overflow Discharge ` (Beaver Crk. PS) 5,000 gallons (N. Toe Rvr.) Without Valid DWQ Incident # 201401653 Permit Remedial actions should be taken to 'correct this problem. The Division of Water Resources may pursue enforcement action for this and any additional violations of State'law. You should address the causes of noncompliance and all actions taken to prevent the recurrence of similar situations. If you should have any questions, please do not hesitate to contact Linda Wiggs at 828-296-4500. Sincerely, G. Landon Davidson, P.G., Regional Supervisor Water Quality Regional Operations Asheville Regional Office ` MSC 1617-Central Files -Basement PERCS Unit G:\WR\WQ\Mitchell\Collection Systems\Spruce Pine Collection System\NOV-2014-DV-0253.SSO.10-2014.doc Water Quality Regional Operations —Asheville Regional Office 2090 U.S. Highway 70, Swannanoa, North Carolina 28778 Phone: 828-296-4500 FAX: 828-299-7043 Internet: hftp://portal.ncdenr.org/weblwq An Equal Opportunity \ Affirmative Action Employer Town of Spruce Pine System Performance Annual Report (SPAR) Submitted as required by the NC General Assembly House Bill 1160 Clean Water Act of 1999. Reporting Period: January 1, 2014 to December 30, 2014 I. General Information: • Name of regulated entity: • Responsible person: Responsible "'s title: Official's location: Mailing address: Phone number: WWTP address: County: DWQ Regional Office: Town of Spruce Pine Sewer Collection System and Wastewater Treatment Plant Richard Canipe Town Manager www.sprucepine-nc.gov 106 Highland Avenue, Spruce Pine 28777 PO Box 189; Spruce Pine, NC 28777 828-765-3000 909 Creed Pitman Road, northeast of Spruce Pine Mitchell Asheville • Listing of permits: NCO021423 Wastewater Treatment Plant WQCS00091 Sewer Collection System WQ0002349 Land Application of Residuals • Description of sewer collection system and wastewater treatment plant: Sewer Collection System (CS): WQCS00091 Class II Consists of 1195 sewer connections (as of 1-13-2015) serving a population of 2050.. There are — 30 miles of gravity sewer and — 10.5 miles of force main (-171,178 ft total). There are 14 duplex pump stations: none have SCADA, 7 have telemetry, 14 have dual high water alarms, and 7 have diesel emergency generators on -site. The fuel vender is Tri-Co Oil Company (Spruce Pine). The equipment service contactor is Blue Ridge Standby Power (Marion). The generators (self -tests weekly) are located at the following pump station locations: Beaver Creek pump, station - 60 KW -Kohler Burleson Hill pump station - 75 KW - Generac Carter's Ridge pump station - 100 KW - Generac DOC Prison #1 pump station - 80 .KW - Onan DOC Prison # 2 pump station - 60 KW - Generac Shannon Drive pump station — 25 KW - Kohler Mitchell High pump station — 26 Kw - Kohler Ten percent (17,118 ft.) of the system is required to be cleaned annua of 17,000 feet of line was cleaned in 2014.EI-Mv.i IM, _ are scheduled for cleaning. There have been two new generators and lift stations added. This includes l 2 miles of gravity, sewer, — 3 miles of force main and two new lift stations to connect the Mitchell County High School (in Ledger). This eliminated the discharge of NPDES permit # NC0066737 which is'a 0.0144 MGD WWTP consisting of: two septic tanks; dosing tank with dual alternating pumps; dual surface sand filters; 20 gpm UV disinfection;_ and effluent aeration tank. Wastewater Treatment -Plant (WWTP): NC0021423 Class III 2.0 MGD (phased permit 0.5 MGD & 2.0 MGD) WWTP consisting of: US Filter Rex III (Envirex) ® mechanically cleaned bar screen (in operation since 1998 — needs replacing); potable water hydrant at influent (for wash down water) (needs repair or replacement); (screenings disposal — GDS pick-up 2/mo to landfill); influent pump station with duplex 1111 gpm pumps with audible high water alarm and autodialer; Eutek TeaCup O headworks grit removal system; (grit disposal — GDS pick-up every 60 days to landfill); (trickling filter — out of service); Milltronics HydroRanger 0 influent ultrasonic flow. meter; Hach Sigma 900 O refrigerated composite sampler; Siemens Orval ® three concentric ring oxidation ditch with four 40 HP rotary aerators; circular clarifier (# 3— out of service) dual 55 ft dia circular clarifiers; (#1 — in service; #2 clarifier — out of service); sludge pump station with duplex 1389 gpm wet well pumps; ` gas chlorine -feed system (uses 150 #,cylinders); baffled chlorine contact basin (converted primary clarifier); Wallace and Tierman Acutec 35 sulfur dioxide gas injection dechlorination feed system (uses 150 # cylinders); dechlorination basin; American Sigma 0 refrigerated effluent composite sampler;, (anaerobic sludge digestor — out of service); aerobic sludge digestor with dual 25 HP floating aerators (converted one old ASB, other one never converted); 1.0 meter Ashbrook Klampress O belt filter press (— 20% solids); polymer feed system with Brennfloc CP622 O (cationic); 3 sludge drying beds; 300 KW diesel Spectrum.3000S emergency generator with automatic transfer switch (Blue Ridge Standby Power); 90 degree v-notch weir; and Endress-Houser® ultrasonic flow measuring equipment with totalizer and circular chart recorder. Sludge Management: WQ0002349 Land Application of Residuals The sludge drying beds have not been used in several years, nor has the land application site been used in several years. Sludge is dewatered utilizing a cationic polymer and 1.0 meter Ashbrook Klampress O belt filter press. The belt press is operated 2 days per week. The dried sludge is.hauled by E. Luke Green Co. to the Iris Glen Landfill, located in Johnson City, TN. II. Performance Summary: Description of overall 12 month performance, noting highlights and deficiencies. By month, list of the number and type of any violations of permit conditions, environmental regulations or environmental laws, including (but not limited to): Permit Limit Violations (NOVs and Civil Assessments) October 2014 there was approximately 5000 gallons of sewage spilled at Riverside Park that entered the North Toe River. This was reported to the DWQ and a statement was issued on channel 13 WLOS for public notification. This was a violation of the collection permit. This was from .an unusual power issue. The flow calculation on the effluent discharge weir was calculated on the wrong angle. The bar -screen was noted in need of replacement. None of these required a civil assessment. Monitoring and Reporting Violations (NOVs and Civil Assessments) (Illegal) Bypass of treatment facilities` 2014 there were none Sanitary Sewer Overflows* - NOVs and Civil Assessments (*Estimated total monthly volumes and locations .of events in which more than 1,000 gallons of waste reached surface waters. October 2014 there was approximately 5000 gallons of sewage spilled at . Riverside Park that entered the North Toe River. This was reported to the DWQ and a statement was issued on channel 13 WLOS for public notification. This was a violation of the collection permit: Description of -any known environmental impact of violations 2014 - none known Description of corrective measures taken to address violations or deficiencies The weir on the, waste plant effluent discharge was recalculated to the right angle two days after it was found. The flow is now accurate. The existing Bar Screen is functional but not efficient. We are currently seeking funding and design for a replacement device. Summary: The wastewater treatment plant and sewer collection system is well operated and maintained by the contractors and Town's staff. The overall performance indicates general compliance with permits. There are several pieces of equipment that are in need of replacement, due to age and wear. The Town budgets annually for needed replacements to maintain efficient operations. III. Notification Copies of the System Performance Annual Report (SPAR) are available upon request at the Town of Spruce Pine's Town Hall. IV. Certification A. Certified Operators in Responsible Charge: Operator information: WWTP ORC contractor: WWTP ORC: WWTP back-up ORCs: >� Coll. Sys. ORC: Coll. Sys. back-up ORC: American Water Darrell J. Graham Phillip D. Burleson Russell P. Lankford Joseph Simmons Elbert E Stamey III Alan Dale Robinson (www.amwater.com) Cert. # 25819 WW-III Cert. # 9907 WW-II Cert. # 29246 WW-III Cert. # 985166 CS-1 Cert # WW-III Cert. # 990612 CS-1 Cert. # 990618 CS-1 B. Statement by a responsible official certifying the report is accurate and complete: I, Richard Canipe, certify that this report is accurate and complete, to the best of my knowledge. Signature of responsible official and date of report: Richard Canipe Date April 2, 2015 Mr. Richard Canipe Town Manager Town of Spruce Pine PO BOX 189 Spruce Pine, NC 28777 martin.mcgill.- management consulting . ■ RE. Wastewater Capital Improvement Plan, Financial Analysis & Rate Study Dear Mr. Canipe, Martin -McGill is pleased to submit this proposal to furnish services for .the above referenced project. It us our understanding that this project need is being driven by DENR's recent site visit to the Town where one of the outcomes was for the Town to update its wastewater CIP. The proposal below outlines our proposed scope for completing the wastewater CIP, incorporating the CIP into the financial analysis produced during our recent Water CIP project and finally, as an optional service, performing a water / sewer rate study: Proposed Scope of Services Our firm's approach to the project is a series of specific tasks designed to address the proposed project in accordance with the Town's request. Each task is described in sufficient detail to allow the Town to determine each task's objective and scope. Wastewater Engineering Program Planning 1. Collect and review existing wastewater program goals and plans, previous capital project plans, cost estimates, studies, interlocal agreements and any other documents that present information and data pertaining to proposed or pending capital projects or.unmet capital needs. . 2. Conduct work session with the Town to: a. Review the Town's previous Capital Improvement Plan and discuss projects that were completed and could be removed. Discuss potential needs for additional support surrounding completed projects. Also review non completed projects and determine which should remain as _ a planned initiative and which are no longer a priority and can be removed. b. Outline new wastewater related capital needs. C. Identify new operating and maintenance expenses and/or users that will be created due to proposed capital projects. 3. Prepare cost estimates for proposed projects and related expenses. 4. Document proposed sewer capital projects, costs, timing and duration of each effort within the 10-year_ planning timeline for each of the efforts identified. Developing the Capital Improvements�Plan Using the cost and timing estimates provided by the engineer, our financial team will then: 1. Review the needs for miscellaneous capital assets including vehicles and equipment. 2. Distinguish between projects that are routine or re -occurring capital outlay from those that are non -routine and involve substantial capital investments, involving specific appropriations or debt. 3. Develop a 10 year CIP schedule that depicts the Town's Wastewater Capital Improvement, operations M and maintenance needs during the planning period along with their representative cost estimates and o proposed timeline. 4. Review and update the projects that were outlined in the 2014 Water CIP planning effort to include the wastewater improvements. Cz a 5.. Address methods of financing each project contained in the CIPs including the use of existing revenues, anticipated revenues from related new users, and new debt. Financial Analysis Update the financial analysis of the revenues and expenses associated with -the Water and Sewer Enterprise Fund. This analysis would be prepared for a ten-year period. It would evaluate the cost of providing water and sewer services, project revenues and expenditures, estimate appropriate annual allocations for capital outlay, and determine future debt service requirements. Rate & Fee Review {OPTIONAL} 1. Update the rate model (fixed/volume rate structures) that identifies water and sewer costs, identifies user groups, and addresses water/sewer equity. The model would propose viable alternative approaches for user rates. 2. Analyze the Town's current tap and cost recovery water and sewer fees and compare against peers and industry best practices. Make recommendations for changes / improvements as identified. 3. Generate an updated rate review, which would use the financial analysis as the basis for establishing the present and future needs for new revenues from water and sewer rate increases. Rate changes would . be recommended which address future revenue requirements, while maintaining a structure that can be implemented by the Town -and easily understood by customers. Final Steps and Deliverables ■- Prepare a draft report, CIP and financial model. ■ Present the draft to the Town Manager for final review. Make refinements to the draft based on the Manager's input. ■ Prepare and make a presentation of the study's findings and' conclusions to the Town Council in a Work Session, ■ Make Town Council refinements to the final draft, and publish the final report. Assumptions ■ Town will provide copies of all needed reports and any supporting information requested. ■ The engineering team will conduct one work session onsite with the Town to review and plan for wastewater improvement initiatives. ■ The financial team will conduct two working sessions to prepare assumptions and review the findings and conclusions of this study. ■ The financial team will attend one Council work session to review the findings and recommendations in the plan. ■ Not included in the. rate study is the analysis of the various additional fees the Town charges for certain activities. This can be included for an additional fee. Proposed Proiect Fee: Martin -McGill proposes to provide services for the scope outlined within for a fees described above, plus reimbursable expenses. Our fee would be assessed monthly based on progress, in accordance with Martin-McGill's and McGill Associate's current schedule of fees and expenses. Work Product Fee Team Assigned Wastewater Engineering Program Planning $5,000 McGill Associates Capital Improvement Plan and Financial Analysis $11,500 Martin -McGill Total $16,500 OPTIONAL W/S Rate / Fee Study $6,500 Martin -McGill bn CZ w We are excited about the opportunity to once again serve you and the Town of Spruce Pine on this important project and we are prepared to begin work immediately upon receipt of your notice to proceed. We would be pleased to meet with you to discuss .the proposed scope of work, at your convenience. Sincerely, Martin -McGill, Inc. Jessica Martin -Lane Partner The terms and conditions outlined in this Martin -McGill proposal are accepted by the Town of Spruce Pine and you are hereby authorized to proceed: Richard Canipe Town Manager Date M w O M a) an CZ a -Pat McCrory Governor Ala NCDENR North Carolina Department of Environment and Natural Resources John E. Skvada, III Secretary December 31, 2014 CERTIFIED MAIL RETURN RECEIPT REQUESTED 7012 1010 0002 1967 9019 Richard Canipe, Town Manager - Town of Spruce. Pine _ P.O. Box 189 Spruce Pine, NC 28777 SUBJECT: NOTICE OF VIOLATION Collection System Inspection Spruce Pine Collection System -NOV=2014-PC=0272 Permit No: WQCS00091 Mitchell County Dear Mr. Canipe:. Enclosed please' find a copy of the Inspection. Reportfrom- the inspection conducted on November. 21, 2014. The Collection System Inspection was conducted by Linda Wiggs of the Asheville Regional, Office. You, -were present during the inspection as were Russell Lankford, Darrell Graham, Elbert &amey and Joe Simmons: The collection system program was found to be in violation of Permit. WQCS00091 for the following items: Performance Standards: Permit Condition # I..4. The fats, oils and grease education is occurring once a year via text in the water. bills. Distribution of educational material is required twice a year. Permit Condition # I. 5. The Capital Improvement Plan (CIP) is dated through 2015-16; a new CIP covering 3-5 years will need to be developed. Permit Condition # f. 6. The manhole just upstream of the Depot pump station has what appeared to be a bypass/overflow line. This line has to .be immediately removed or permanently capped. Operation and Maintenance: Permit Condition # II. 1. There is not an Operator in Responsible Charge (ORC) designated who possesses a valid certificate of a grade CS-2. The permit requirement for the Permittee to designate an ORC was. required by mid -April 2013. An ORC designation form shall be submitted immediately. 3 Water Quality Regional Operations —Asheville Regional Office 2090 U.S. Highway 70, Swannanoa, North Carolina 28778 Phone: 828-2964500 FAX: 828-299-7043 Internet: http://portal.ncdenr.org/weblwq/ An Equal Opportunity 1 Affirmative Action Employer 1 71v Spruce Pine Collection System a December 31, 2014 Page 2 of 2 Other items of deficiencies were also noted; if not address these items could lead to violations. Performance Standards: Permit Condition # I. 4. The Depot pump station had been pumped 2 weeks prior to the inspection; however the pump station had a fair amount of grease present —This pump station receives several non-residential users; increased attention/actions to these users according to the local Grease Ordinance may be warranted. Operation and Maintenance: Permit Condition # I. 2. The line along the south side of the North Toe River between the manholes at TriCounty Oil and -the Ball -Field needs immediate cleaning: -Inspection of the-inanholes-along this -line -revealed 4" of sediment (sand, gravel) present. Where. this sediment is coming from also needs to be evaluated and remediated. Records/Inspections: Permit Conditions # III. 1. and # V. L .Record keeping needs to be improved. Ms. Wiggs sent an email on December 11, 2014 to you containing collection system operator logs_ that should be considered for use to assist in improving the records requirements. The collection system map also needs to be updated. Please refer to the enclosed inspection report for important details on the inspection. To prevent further action, carefully review these violations and deficiencies and respond in writing to this office within thirty (30) calendar days of receipt of this letter. You should address all actions taken"and/or list specific timelines when actions will be taken to prevent the recurrence of similar -situations. If you should - have any questions, please do not hesitate to contact Linda Wiggs at 828-296-4500. Sincerely, G. Landon Davidson, P.G., Regional Supervisor Water Quality Regional Operations. Asheville Regional Office Enc. Inspection Report cc: MSC 1617-Central Files -Basement �AROaFiles G:\WR\WQ\Mitchell\Collection Systems\Spruce Pine Collection System\CEI.NOV-2014-PC-0272.doc Compliance Inspection Report Permit: WQCS00091 Effective: 04/01/13 Expiration: 03/31118 - Owner: - Town of Spruce Pine SOc: Effective: Expiration: Facility: Spruce Pine Collection System County: Mitchell . PO Box 189 Region: Asheville Spruce Pine NC 28777 Contact Persons Richard Canipe` Title: Town Manager"' Phone: 828=765-3000 Directions to Facility: System Classifications: CS2, Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Re presentative(s):,. J. Related Permits: NC0021423 :. Town of'Spruce Pine- Spruce Pine VWVf P Inspection Date: 11/21/2014 Entry Time: 10:OOAM Exit Time: r 02:OOPM — Primary Inspector: Linda S Wiggs A / D� Phone: 828-296-4500 Ext.4653 Secondary Inspector(s): Reason for Inspection: Routine" Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Collection system management and operation Facility Status: ❑ Compliant Not Compliant Question Areas: Miscellaneous Questions Performance Standards Operation & Maint Regmts-- Records Monitoring & Rpting Reqmts E .Inspections Pump Station Manhole Lines (See attachment summary) Page: 1 J f Permit: WQCS00091 Owner -Facility: Town of Spruce Pine Inspection Date: 11/21/2014 Inspection Type: Collection System Inspect Non Sampling Reason for visit: Routine Inspection Summary: Performance Standards: Permit Condition # I. 4. FOG education is occurring once a year via text in the water bills. Distribution of educational material is required twice a year. The Depot PS had been pumped 2 weeks prior; however the PS had a fair amount of grease present. This.,PS receives several non-residential users; increased attention/actions to these users according to the local Grease Ordinance maybe warranted. Permit Condition # 1. 5. The CIP is dated through 2015-16; a new CIP covering 3-5 years will need to be developed. Permit Condition # 1.6. The manhole just upstream of the Depot PS has what appeared to be an overflow line. This line has ---to-be-immediately-removed-or-permanently-capped------------------------------- -- — --- —---------------------------------=-- Operation and Maintenance: Permit Condition # II.1. There is not an ORC designated who possesses abalid certificate of a grade CS-2. The permit requirement for the Permittee to designate an ORC was required by mid- April 2013. An ORC designation form shall be submitted immediately. Permit Condition # 1.2 and # 11. 8. The line along the south side of the river between the manhole at TriCounty Oil and the Ball Field needs immediate cleaning. Inspection of manholes along this line revealed 4" of sediment (sand, gravel) present. Where this sediment is coming from also needs to be evaluated -and remediated. Records/Inspections: Permit Conditions # III. 1. # V. 1. Record keeping needs to be improved. The inspector sent an email on December 11, 2014 to Mr. Canipe containing collection system operator logs that should be considered for use to assist in improving the records requirements. The map also needs to be updated. Page: 2 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/21/2014 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Performance Standards Yes No NA NE Is Public Education Program for grease established and documented? ❑ ❑ ❑ What educational tools are used? Text within the water bill is sent annually. Need to send FOG information twice a year. Consider using forms sent via email on 12/11/2014 to document FOG education. Also consider using a flyer insert or something more than text to catch the user's attention. Is Sewer Use Ordinance%Legal-_ uthority available?__ -__ __. . _._ _ _. _...._ - _ _. -_ .: __.__ . __ __- _ W❑_ ❑_❑ Does it appear that the Sewer Use Ordinance is enforced? ❑ ❑ ❑ Is Grease Trap Ordinance available? 0 ❑ 1:3 ❑ Is Septic Tank Ordinance available (as applicable, i.e. annexation) El ❑ ❑ List enforcement actions by permittee, if any, in the last 12 months J Has an acceptable Capital Improvement Plan (CIP) been implemented? WO ❑ ❑ Does CIP address short term needs and long term \"master plan\" concepts? M ❑ ❑ ❑ Does CIP cover.three to five year period? _❑ ❑ ❑ Does CIP include Goal Statement? M ❑ ❑ El Does CIP include description of project area? W Q ❑ ❑ Does CIP include description of existing facilities? M ❑ ❑ ❑ Does CIP include known deficiencies? 0. ❑ El ❑ „ , Does CIP include forecasted future needs? 0 ❑ ❑ ;❑ . Is CIP designated only for wastewater collection and treatment? M ❑ ❑ ❑ Approximate capital improvement budget for collection system? $828,000.00 Total annual revenue for wastewater collection and treatment? $187,000.00 CIP Comments The CIP is only until 2015-2016. A new one will need to be developed through the next M years. Grease Trap inspections and FOG education in the vicinity of Depot PS needs to be'increased. Is system free of known points of bypass? ❑ ❑ ❑ If no, describe type of bypass and, location A bypass line was found during the inspection of the manhole just upstream of the Depot PS. This bypass will have to be removed immediately. Is a 24-hour notification sign posted at ALL pump stations? ❑ ❑ ❑ # Does the sign include: Instructions for notification? ❑ ❑ ❑ Pump station identifier? 0 ❑ ❑ ❑ 24-hour contact numbers ❑ ❑ ❑ If no, list deficient -pump stations # Do ALL pump stations have an "auto polling" feature/SCADA? ❑ 0 ❑ ❑ Number of pump stations 14 Page: 3 . f Permit: WQCS00091 Owner - Facility: Town of Spruce, Pine Inspection:Date: 11/21/2014 Inspection Type : Collection System Inspect Non Sampling Reason for Visit: Routine Number of pump stations that have SCADA o Number of pump stations that have simple telemetry Number of pump stations that.have only audible and visual alarms Number of pump stations that do not meet, permit requirements # Does the permittee have a root control program? # If yes, date implemented? Describe: _ __. The_town has a jetterwith- a -cutter head.-- Comment: Inspections Are maintenance records for sewer lines available? Are records available that document pump station inspections? Are SCADA or telemetry equipped pump stations inspected at least once a week? Are non-SCADA/telemetry equipped pump stations inspected every day? Are records available that document citizen complaints? # Do you have a system to conduct an annual observation of entire system? # Has there been an observation of remote areas in the last year? Are records available that document inspections of high -priority lines? Has there been visual inspections of high -priority lines in last six months? Comment: All PS are inspected daily. Operation & Maintenance Reauirements Are all log books available? Does supervisor review all log books on a regular basis? Does the supervisor have plans to.address documented short-term problem areas? What is the schedule for reviewing inspection, maintenance, & operations logs and problem areas? As needed, regularly. Are maintenance records for equipment available? Is a schedule maintained for testing emergency/standby equipment? What is the schedule for testing emergency/standby equipment? Do pump station logs include: . Inside and outside cleaning and debris removal? Inspecting and exercising all valves? Inspecting and lubricating pumps and other equipment? Inspecting alarms, telemetry and auxiliary equipment? Is there at least one spare pump for each pump station w/o pump reliability? Are maintenance records for right-of-ways available? Are right-of-ways currently accessible in the event of an emergency? T 7 ❑ ❑ ❑ Yes No NA NE ❑ ❑ ❑ ❑ ❑ ❑ 0,❑ ❑❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑❑■❑ ❑ ❑ ❑ ■❑❑❑ .. Yes No NA NE ❑ ❑ ❑ ■❑❑❑ 0• ❑ ❑-❑ ❑ ❑ ❑ ❑ ❑ ❑ 0❑❑❑'. ■❑❑❑ ■❑❑❑ ■❑❑❑ ❑ ❑ ❑ ❑ ❑ ❑ Page: 4 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/21/2014 Inspection, -type : Collection System Inspect Non Sampling Reason for Visit- Routine Are system cleaning records available? ❑ ❑ ❑ Has at least 10% of system been cleaned annually? ❑ ❑ ❑ What areas are scheduled for cleaning in the next 12 months? Line along the river,has signficant sediment buildup. Phone discussion with Mr. Canipe.informied him this line had to be a priority:' ; Isl a,Spill Response Action Plan available? 0 ❑ ❑ El D h I oes t e p an Include. 24-hour contact numbers , ❑ ❑ D Response time 0 ❑ ❑ ❑, Equipment list and spare parts'inventory ❑ ❑ El ; Access to cleaning equipment ❑ ❑ ❑ Access to construction crews, contractors, and/or engineers ❑ ❑ -❑ Source of emergency funds 0 ❑ El ❑ Site sanitation and: cleanup materials ❑ ❑ "❑ Post-overflow/spill assessment ❑ ❑ ❑ .. Is a Spill Response Action Plan available for all personnel? 0 ❑ : ❑ ❑ Is the spare parts inventory adequate? 0 ❑ ❑ ❑. Comment: Emergency/After hour phone numbers to report SSO need to be added to SRAP. Redords Yes No NA NE Are adequate records of all SSOs, spills and -complaints available? 0 -❑ ❑ ❑ Are records of SSOs that are under the reportable threshold available? ❑ ❑ ❑ Do spill records" indicate repeated overflows (2 or, more in 12 months) at same location? : ❑ E ❑ ❑ i If yes, is there'a corrective action plan? 0 ❑ ❑ 13 r Is a map;of the system, available? - .❑ ❑ ❑• Does the map include: Pipe sizes . . ❑ Ell ❑ Pipe materials ❑ ❑ El I Pipe location 0 ❑ ❑ ❑ Flow direction. , . ❑` 9 `❑ ❑ ' Approximate pipe age ❑ NEE , Number of service taps ❑ 0 ❑ ❑ Pump stations and capacity .❑ .E ❑ ❑ If no,. what percent is complete? List any modifications and extensions that need to be added to the map Map needs to be updated. Mr. Canipe stated their consultant will be. updating the map. # Does the permittee have a copy of their permit? _r ❑ ❑ ❑ Comment: _ ' - Page: 5 iS Permit: WQCS00091 Owner -Facility: Town of Spruce Pine Inspection Date: 11/2112014 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Monitorinq and Reporting Requirements Yes No NA NE Are copies of required press releases and distribution lists available? 0 ❑ ❑ ❑ Are public notices and proof of publication available? M ❑ ❑ ❑ # Is an annual report being prepared in accordance with G.S. 143-215.1.C? ❑ ❑ ❑ # Is permittee compliant with all compliance schedules in the permits? ❑ ❑ 0 ❑ If no, which one(s)? Comment: TRICOUNTY MH - MH acro: Manhole Is manhole accessible? # Is manhole cover/vent above grade? Is the manhole free of visible signs of overflow? Is the manhole free of sinkholes and depressions? Is manhole cover present? # Is manhole properly seated? # Is manhole in good condition? # Is invert in good condition? Is line free -flowing and unrestricted in manhole? Is manhole free of excessive amounts of grease? Is manhole free of excessive roots? Is manhole free of excessive sand? Is manhole's extended vent screened? Are vents free of submergence? Are manholes free of bypass structures or pipes? Comment: Excessive sand/gravel 4" deep. Evidence of surging. DEPOT PS - Pump Station Purrip'station=type Are pump station logs available? Is it accessible in all weather conditions? # Is general housekeeping acceptable? Are all pumps present? Are all pumps operable? Are wet, wells free of excessive debris? Are upstream manholes free of excessive debris/signs of overflow? 0 Yes No NA NE .M ❑ ❑ ❑ ❑ ❑ ❑ ■❑❑❑ ❑ ❑ ❑ El El ❑ 0❑❑❑ ❑ ❑ ❑ 'M❑❑❑ ■❑❑❑ ❑0❑❑ ❑ ❑ M ❑ ❑■❑ ❑ ❑ ❑ Yes No NA NE Duplex ■❑❑❑ ■❑❑❑ ❑ ❑ ❑ ■❑❑❑ ❑ ❑ ❑ ❑❑❑l ❑■❑❑ Page: 6 Permit: WQCS00091 Owner -Facility: Town of Spruce Pine ° Inspection Date: 11/21/2014 Inspection Type: Collection System Inspect Non Sampling Reason for visit: Routine Are floats/controls for pumps/alarms operable? ❑ ❑ ❑ Is "auto polling"feature/SCADA present? ❑ ❑ 0 ❑ Is "auto polling" feature/SCADA operational? ❑ ❑- M ❑ Is simple telemetry present? ❑ ❑ ❑ Is simple telemetry operational? ❑ ❑ ❑ Are audio and visual alarms present? . ❑ ❑ ❑ Are audio and visual alarms operable? 0 ❑ ❑ ❑ --Is the Pump station inspected as -required?- — - - - - - - - - -' --❑ '❑ ❑ Are backflow devices in place? ❑ ❑ ❑ Are backflow devices operable? ❑ ❑ ❑ Are air relief valves in place? 0 ❑ ❑ ❑ Are air relief valves operable? ❑ ❑ ❑ # Is an emergency generator available? M ❑ ❑ ❑ Can the emergency generator run the pumps? 0 ❑ ❑ ❑ Is the pump station equipped for quick hook-up? ❑ ❑ ❑ is the generator operable? ❑ ❑ M ❑ # Is fuel in tank and sufficient? ❑ ❑ M ❑ Is the generator inspected according to their schedule? 0 ❑ ❑ ❑ Is a 24-hour notification sign posted? 0- ❑ ❑ ❑ Does it include: Instructions for notification? ❑ ❑ I❑ Pump station identifier? M ❑ ❑ ❑ Emergency phone number ❑ ❑ ❑ Is public access limited?" M ❑ ❑ ❑ Is pump station, free of overflow piping? 0 ❑ ❑ ❑ Is the pump station free of signs of overflow? 0 ❑ ❑ ❑ Are,run times comparable -for multiple pumps? Comment: This is a very old PS. It had been pumped 2 weeks ago and there was a moderate amount of grease stil present: Grease Education in this area needs to be increased. The upstream MH has a bypass line. By design you can't see all of the components of this PS. ALONG N. TOE RVR - Sout Lines/Right-of-Ways/Aerie) Lines Yes No NA NE Is right-of-way accessible for emergency? 0 ❑ ❑ ❑ Is right-of-way free of sinkholes or depressions? El❑ El Is line/right-of-way free of evidence of leakage? 0 ❑ ❑ ❑ # Are there areas of exposed line? 0 ❑ ❑ ❑ # Is any exposed line constructed of ductile iron or other approved material? ❑ ❑ ❑ Page: 7 L _ 11 c Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/21/2014 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Are water crossing and supports in good condition? ❑ ❑ M ❑ # Is right-of-way free of non -utility motorized traffic? M ❑ ❑ ❑ Is line free of visible damage? A ❑ ❑ ❑ # Are there siphons in this system? ❑ ❑ M ❑ If yes, are they maintained and documented? Comment: As indicated by MH inspections this line appears to have significant sediment impacts which would cause capacity concerns. The ROW was not clear, it had brush and_sapplings growing. A truck.could get through though_ There was also exposed line between the Tri Co MH and the ball field MH. DEPOT PS MH - MH just up Manhole ' Yes No NA NE Is manhole accessible? 0 ❑ ❑ ❑ # Is manhole cover/vent above grade?0 ❑ ❑ ❑ Is the manhole free ofvisible signs of overflow? 0 ❑ ❑ ❑ Is the manhole free of sinkholes and depressions? 0 ❑ ❑ ❑ Is manhole cover present? ■ ❑ ❑ ❑ # Is manhole properly seated? ❑ ❑ ❑ # Is manhole in good condition? ❑ N ❑ ❑ # Is invert in good condition? ❑ 0. ❑ ❑ Is line free -flowing and unrestricted in manhole? M ❑ ❑ ❑ Is manhole free of excessive amounts of grease? 0 ❑ ❑ ❑ Is manhole free of excessive roots? 0 ❑ ❑ ❑ Is manhole free of excessive sand? ❑ ❑ ❑ Is manhole's extended vent screened? ❑ ❑ 0 ❑ Are vents free of submergence? ❑ ❑ M ❑ Are manholes free of bypass structures or pipes? ❑0 ❑ ❑ Comment: This manhole has a bypass/overflow pipe that will have to be removed/capped immediately. Evidence of surging. BALLPARK MH - MH upstr( Manhole Is manhole accessible? # Is manhole cover/vent above grade? Is the manhole free of visible signs of overflow? Is the manhole free of sinkholes and depressions? Is manhole cover present? # Is manhole properly seated? # Is manhole in good condition? Yes No NA NE ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ Page: 8 Permit: WQCS00091 Owner- Facility: Town of Spruce Pine Inspection Date: 11/21/2014 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine # Is invert in good condition? Is line free -flowing and unrestricted in manhole?1:1 El Is manhole free of excessive amounts of grease? 0 ❑ Is manhole free of excessive roots? Is manhole free of excessive sand? El 0 M ❑ Is manhole's extended vent screened? Are vents free of submergence? Q ❑ N ❑ Are manholes -free of bypass structures or pipes? - - " -Q Q 0 Comment: Excessive amount of sand/_gravel 4". Evidence of sur_gin_g. Are storm drains tied into this line? I 0 Page: 9 February 4, 2015 Ms. Linda Wiggs Water Quality Asheville Regional Office Notice of Violation Collection System Inspection Spruce Pine Collection System NOV-2014-PC-0272 Permit # WQCS00091 Mitchell County Condition # I.4. FOG education will be added to the notes section on the Spruce Pine Water. Bill at least 2 time per year. A packet of information will be developed using information on the NCDENR website and delivered to the restaurants in town. Condition # I. 5. The current C.I.P. is thru 2015 contact will be made with Martin -McGill in Asheville to arrange for an update. Condition # I. 6. The Manhole at the Depot Pump Station on Locust Street has been sealed. Condition # II. 1. Elbert Stamey Public Works Director will be retiring on 3/31/2015. The new Public Works Director will be required to attend the first available school after becoming employed. Dale Robinson will be attending the next available school to work on obtaining CS-2 license. Russell Lankford will serve as backup ORC in the interim. Condition # I.4. Restaurants in the area served by the Depot Pump Station will be l contacted in person and given FOG information. Condition I.2. The Line parallel to the North Toe River will be cleaned by WNC Parking Lots from Asheville as soon as weather permits Condition # III. 1. & V. 1. Forms provided by Linda Wiggs will be incorporated into the current Record keeping. Richard Canipe Town Manager Town of Spruce Pine 828-765-3000 Wiggs, Linda From: Bass, Sarah Sent: Monday, November 17, 2014 10:06 AM To: Wiggs, Linda Subject: RE: Spruce Pine Industrial Waste Survey Attachments: Spruce Pine.HWA.03.pdf Linda, Their last HWA letter made a note that short term monitoring sampling was to occur August 2014 through July 2015. Their next HWA is due September 2015. Also, the letter requested a modified STMP be submitted by May 2014 (CN and Ag needed to be added). This plan has not been modified since 1999. Also, their ERP hasn't been modified since 1994. The plan needs updating to at a minimum change the penalty wording to up to $25,000 per day per violation to reflect the SUO. Our ERP model was updated in 2008 and lists a couple other changes as well mainly for clarification. The main thing would be make sure they've started their STMP sampling and that Cn and Ag have been included as well as the aeration basin needing to be sampled at least once for completion of the HWA. Thanks, Sarah Morrison Bass N.C. Dept. of Environment and Natural Resources Division of Water Resources Pretreatment, Emergency Response and Collection Systems Unit (PERCS) 1617 Mail Service Center, Raleigh, NC 27699-1617 (919) 807-6310; fax (919) 807-6489 http://portal.ncdenr.org/web/wq/swp/ps/pret E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. Before printing this email, please consider your budget and the environment. If you must print, please print only what you need and save ink with the free Eco-Font. -----Original Message ----- From: Wiggs, Linda, Sent: Friday, November 14, 2014 5:06 PM To: Bass, Sarah' Subject: RE: Spruce Pine Industrial Waste Survey Thanks Sarah. I am going to do an inspection_ next Friday (11/21) of their CS and if I have time their WWTP, do you want me to look into anything? Linda Wiggs Linda.Wiggs@ncdenr.gov Environmental Senior Specialist North Carolina Dept. of Environment and Natural Resources Asheville Regional Office Division of Water Resources - Water Quality Regional Operations 2090 U.S. 70 Highway Swannanoa, NC 28778 Tel: 828-296-4500 Fax: 828-299-7043 Link to Division of Water Resources Home Page http://portal.ncdenr.org/web/wq Notice: E-mail correspondence to and'from this address may be subject to the North Carolina Public Records Law and therefore may be disclosed to third parties: -----Original Message ----- From: Bass, Sarah Sent: Wednesday, November 05, 20141:29 PM To: Russell.Lankford@amwater.com Cc: spMgr@bellsouth.net; Wiggs, Linda Subject: RE: Spruce Pine Industrial Waste Survey Thanks Russell. Attached is the PERCS response to the Town's IWS submittal. A hard copy is being mailed. Sarah Morrison Bass N.C. Dept. of Environment and Natural Resources Division of Water Resources Pretreatment, Emergency Response and Collection Systems Unit (PERCS) 1617 Mail Service Center, Raleigh, NC 27699-1617 (919) 807-6310; fax (919) 807-6489 http://portal.ncdenr.org/web/wq/swp/ps/pret E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third. parties. P Before printing this email, please consider your budget and the environment. If you must print, please print only what you need and save ink with the free Eco-Font. -----Original Message ----- From: Russell.Lankford@amwater.com [mailto:Russell.Lankford@amwater.com] Sent: Wednesday, November 05, 201412:15 PM To: Bass, Sarah Cc: spmgr@bellsouth.net Subject: Re: Spruce Pine Industrial Waste Survey Here they are Sarah. Richard got them completed. (See attached file: IWSHC.jpg)(See attached file: IWSHSM.jpg)(See attached file: IWSME.jpg) Russell Lankford Site Superintendent American Water Contract Services 95 Clearwater Lane Spruce Pine NC 28777 2 P:828-765-3011 WTP P:828-765-3007 WWTP C:828-385-1030 F:828-765-3013 E:russell.lankford@amwater.com W:www.amwater.com From: "Bass, Sarah" <sarah.bass@ncdenr.gov> To: "spmgr@bellsouth.net" <spmgr@bellsouth.net>, Cc: "Russell. Lankford@amwater.com" <Russell. Lankford @a mwater.com> Date: 10/31/2014 09:41 AM . Subject:Spruce Pine Industrial Waste Survey Richard, Please see the information requested below. Again, PERCS has not yet received a response on this outstanding information requested on various occasions. Sarah Morrison Bass N.C. Dept. of Environment and Natural Resources Division of Water Resources Pretreatment, Emergency Response and Collection Systems Unit (PERCS) 1617 Mail Service Center, Raleigh, NC 27699-1617 (919) 807-6310; fax (919) 807-6489 http://portal.ncdenr.org/web/wq/swp/ps/pret E-mail correspondence to and from this address may be. subject to the North Carolina Public Records Law and may be' disclosed to third parties. P Before printing this email, please consider your budget and the environment. If you must print, please print only what you need and save ink with the free Eco-Font. From: Bass, Sarah Sent: Tuesday, October 21, 2014 3:57 PM To: 'spmgr@bellsouth.net' Subject: Spruce Pine Industrial Waste Survey Richard, I wanted to follow up regarding the industrial waste survey performed by the Town. Would it be possible to forward a copy of the surveys completed by the following users? This information is outstanding for PERCS' 3 approval of the IWS. A formal response will be sent to the Town once received. 1. Hartsell Scrap Metal 2. Highland Craftsmen, Inc. 3. McKinny Electric & Machine Inc. I believe Russell Lankford forwarded the most recent request in late September, but I hadn't yet received any information. They can be faxed at (919)807-6489 or scanned and emailed to sarah.bass@ncdenr.gov. Thanks for your assistance, Sarah Morrison Bass N.C. Dept. of Environment and Natural Resources Division of Water Resources Pretreatment, Emergency Response and Collection Systems Unit (PERCS) 1617 Mail Service Center, Raleigh, NC 27699-1617 (919) 807-6310; fax (919) 807-6489 http://portal.ncdenr.org/web/wq/swp/ps/`pret E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. P Before printing this email, please consider your budget and the environment. If you must print, please print only what you need and save ink with the free Eco-Font. 4 Tom• l)In �.::. aJ NCDENR { 1 North Carolina Department of Environment and Natural Resources Division of Water Resources Water Quality Programs Pat McCrory Thomas A. Reeder John E. Skvarla, III Governor Director Secretary September 23, 2013 Richard Canipe Town of Spruce Pine PO Box 189 Spruce Pine, NC 28777 Subject: NOTICE OF VIOLATION NOV-2013-DV-0197 Permit No. WQCS00091 Town of Spruce Pine Spruce Pine Collection System Mitchell County Dear Mr. Canipe: A review has been conducted of the Spruce Pine Collection System's self -reported Sanitary Sewer Overflows (SSO's) 5-Day Report submitted by Town of Spruce Pine. This review has shown the subject facility to be in violation of the requirements found in Collection System Permit WOCS00091 and/or G.S. 143-215.1(a)(1). The violation that occurred is summarized below. Area Violation Date Sanitary Sewer Overflow (SSO) Violation Type Biggerstaff Rd. 07/20/2013 5,000 gallons Discharge DWQ Incident # 201301674 Without Valid Permit Remedial actions should be taken to correct this problem. The Division of Water Resources may pursue enforcement action for this and any additional violations of State law. You should address the causes of noncompliance and all actions taken to prevent the recurrence of similar situations. `If you should have any questions, please do not hesitate to contact Linda Wiggs at 828-296- 4500. Sincerey� andon Davidson, P.G. Regional Supervisor Water Quality Section Cc��DWRARO iles Central Files PERCS Unit G:\WQ\SWP\Mitchell\Collection Systems\Spruce Pine Collection System\NOV-2013-DV-0197.SSO.doc Water Quality Section—ASHEVILLE REGIONAL OFFICE Location: 2090 U.S. Highway 70, Swannanoa, NC 28778 Phone: (828) 296-4500\FAX: 828 299-7043 Internet: www.ncwater(ivality.org BFILE COPY NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director Surface Water Protection Section June 22, 2011 Ken & Sharon Hollifield Rock House Creek Properties 124 Ray Wiseman Road Spruce Pine, NC 28777 Charles Wiseman Rock House Creek Properties 968 West. Blvd. Hartford, Conneticutt 06105 Dee Freeman Secretary Subject: Grassy Creek Shopping Center Private Collection System Repairs Mitchell County Dear Owners: According to our records, Mr. Allen Hughes, Environmental Health Supervisor, Toe River Health District, reported the discharge of sewage from your private collection system.' The incident, was reported on 3-9-11, and occurred as a result of flooding in the creek and a piece of wood separating the 4-inch pvc sewer pipe, which caused the discharge of sewage into Grassy Creek. It is our understanding that repairs were made using schedule 40 PVC pipe. The private sewer collection system that serves the Grassy Creek Shopping Center with sewer connections from: KB's Bar-B-Que, Subway Restaurant, Grassy Creek Hardware, McKinney -Computers and one private residence, does not meet 15A.NCAC 02T :0305 and 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria (adopted February 12, 1996) and the Division's minimum design criteria for collection systems. SURFACE WATER PROTECTION SECTION —ASHEVILLE REGIONAL OFFICE Location: 2090 U.S. Highway 70, Swannanoa, North Carolina 28778 NofthCarohna Phone: 828-296-45001 FAX: 828-299-70431 Customer Service:1-877-623-6748 Internet: www.ncwaterquality.org An Equal Opportunity l Affirmative Action Employer Grassy Creek Shopping Center June 22, 2011 Page 2 of 2 This system was installed many years ago, however, any time the collection system is damaged, the repairs and replacement must meet the current minimum design criteria and regulations. In order to meet the minimum design criteria for sewer collection systems, the exposed part of the collection system must be constructed of ferrous pipe (ductile iron, steel, etc.). Currently, the exposed section of pipe in the creek does NOT meet these standards and will need to be replaced using ferrous pipe materials. In addition, piers must be designed and installed to support the collection lines. Loose rock placed by hand will not support, nor keep the collection line from shifting, and will eventually result in the failure of the collection system. The system appears to be functional at this time. However, whenever leaks, damages and failures occur, it must be redesigned and replaced according to engineering standards and minimum design regulations When heavy rains or flooding occur in the future, the PVC line will be damaged. At that time, you will need to be prepared to make corrections in accordance with minimum design standards. You will need to contact a North Carolina -licensed Professional Engineer to submit a Fast -track Collection System application to the Division, in preparation of that event.. If the engineer anticipates that work will cause the stream to be disturbed or if digging in the stream is required, then a 404 certification from US Army Corps. of Engineers and a 401 certification from the Division will be needed. DOT appears to be viewing this as an illegal encroachment. Please have your engineer contact DOT, as well. Please feel free to contact Wanda Frazier of the Asheville Regional Office at 828-296- 4662, should you have questions regarding this matter. Sincerely, WE I I 6, , r Roger C. Edwards, Regional Supervisor Surface Water Protection Section cc: Allen Hughes, Toe River District Health Department Central Files VhhMfltel iles', se� le, Grassy Creek Shopping Center u" Hwy 226; Spruce Pine Mitchell County Rock House Creek Properties — family owned business Ken & Sharon Holliifield 124 Ray Wiseman Road Spruce Pine, NC 28777 Charles Wiseman 968 West. Blvd. Hartford, Conneticutt 06105 (cell: 467-1839; home: 765-4557.) (Sharon Wiseman Hollifield's brother) Private Collection System that serves a shopping center with connections from: KB's Bar-B- Que, Subway, Grassy Creek Hardware, McKinney Computers, and one private residence. According to Elbert Stamey (cell: 385-0448; office: 765-3005), Town of Spruce Pine, this private collection system was installed in 1988. He found the paperwork for it. The owners asked the Town Manager, Richard Canipe, if the Town would take it over. They declined. Allen Hughes (cell: 385-1801; office: 765-2239 x 13), Environmental. Health Supervisor, Toe River Health District, reported the incident on 3-9-11 (BIMS incident # 201100562). There had been some flooding in the creek and a piece of wood separated the 4-inch pvc sewer pipe, discharging sewage into Grassy Creek. According to Ken Hollifield, they called Mark Presnell, Roto Rooter and Burleson Pumbing to look at it. Sharon Hollifield said that they fixed it themselves. Ken said that they used schedule 40 pvc pipe. They didn't know about the requirements for replacing the exposed portion of the line. NC Plumbing code .requires that exposed collection systems consist of ferrous pipe (ductile iron, steel, etc.). This is the requirement for meeting the minimum design criteria for collection. systems. Emails from Roger: 6/16/2011 1:35 PM Wanda the name of the plumber is Mark Aaffaph Plumbing Co. Sory I don't have a phone number. Have you tried the county tax collector office for this property. 6/14/2011 10:57 AM Due to the time this private collection system is assumed to have been permitted there is likely no permit for the Grassy Creek private collection system. Just send the owners or all connected to the line a letter of notification. 6/14/2011 10:17 AM The Mitchell County, Grassy Creek private collection system needs a letter explaining when this line fails or leaks it must be replaced meeting minimum design standards. 618/2011- 11:46 AM I have no, information on this private collection system. I spoke with the plumber when he called in the SSO from the system. He indicated the owner was aware of the issue and intended to make corrections. I have not heard anything since. This is a bad situation and does not meet our regulations. The owner(s) can be proactive to correct the problem or wait and make repairs when a storm event takes out the collection system line. Also, DOT may have issue with the line going through their culvert. Mike can provide insight into DOT's position on that issue. Please send a letter to the owner(s) of this collection system notifying them the collection system does not meet minimum design regulations and encourage them to make updates. Additionally, point out that minimum design regulations will be required to be met when a storm event results in the collection system. line being damaged and leaking wastewater to the stream 4 • NCDENR North Carolina Department of Environment a Division of Water Quality Beverly Eaves Perdue Charles Wakild, P. E. Governor Director December 3ra, 2012 r r-xe,5our-Qes �'T- 31 ©ee-F7e Sec ry .. FDE1 201 1 �L) ;�-' WATERCTYo SI MEMORANDUM TO: Chuck Cranford - Asheville Regional Office, Surface Water Protection FROM: Michael Leggett, P.E. PERCS Unit SUBJECT: Town of Spruce Pine Application Package Permit No. WQCS00091 The subject collection system permit application was received by the central office on November 301t', 2012. A copy of the Collection System application package is attached for your records and comments. If you have any questions or comments please contact me at (91.9) 807-6312 or via email at michael.leggett@ncdenr.gov. enclosures: application package cc: PERCS Unit (electronic copy) 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Raleigh, North Carolina 27604 NOne hCarolina Cw Phone: 919-807-63001 FAX: 919-807-6492 A ,.��u'/N���� Internet: www.naterguality.org �//�YJ An Equal Opportunity\ Affirmative Action Employer OF WATER State of North Carolina `off QG Department of Environment and Natural Resources Division of Water Quality o < SYSTEM -WIDE WASTEWATER COLLECTION SYSTEMS FORM CSA 10105 (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) Application Number. (to be completed by DWQ) <THIS ONLINE APPLICATION CAN BE FILLED OUT USING THE TAB KEY TO MOVE THROUGH THE FIELDS> I. GENERAL INFORMATION:, Owner name of the municipality,public utility, homeowners association, etc.: Town of Spruce Pine Richard Cani a Town Manager P.O. Box 189 Spruce Pine State: North Carolina 28777 828-765-3000 828-765-3014 E-mail: s m r bellsouth.net Mitchell Richard Cani a Town Manager Is this application new or fora permit renewal? ❑ New x❑ Renewal of Permit No. W CS0091 H. COLLECTION SYSTEM INFORMATION: 1. Owner and name of wastewater treatment facility(ies) (WWTF) receiving wastewater. Town of Spruce Pine 2. WWTF permit number(s): NCO021423 3. Total miles of sewer (approximate): 15 Force Main 35 Gravity —..__4 stem: -60 — Pressure Vacuum 5. Wastewater Make -Up: 90 % Domestic/Commercial 10 % Industrial (Process) 6. Pump Station Information: Attach a current list of all major (i.e. not simplex serving a single family home as part of a pressure sewer system) pump stations, names, capacities and their locations. Summarize below: o Number of simplex pump stations serving a low pressure* sewer. 0 * Indicate the number of simplex type pump stations serving a low pressure sewer system that are owned/maintained such as in a residential subdivision. This would not include pump stations that convey larger flows en route to the treatment plant or individual pumps needed to pump to an adjacent gravity sewer. If simplex stations are listed above, pressure or vacuum mains should be shown in Item 11(3). o Number of duplex or greater pump stations: 14 o Number of simplex stations serving multiple buildings: 0 7. Attach a list of high priority lines according to the Division's definition known to exist in the collection.sysi m"(See Instruction E). Head the list with the system name and include "Attachment A for Condition V( i 8. Attach a copy of your current spill response plan. ® lv- Nw 3 s FORM: CSA 10105 9. Attach a copy of your current annual budget and current approved Capital Improvement Plan. 10. Attach a copy of your comprehensive collection system map (a CD is also acceptable, please indicate format). maP is Cu42��+/7 7&oeu y A /Aww.-✓ 11. Report any satellite systems over 200,000 gallons per day (see Instruction F). For renewals, only indicate those re systems that anewly connected or have exceeded 200,000 galons per day since the last permit application. 0 12. Indicate the current designated collection system operators: Main ORC Name: Elbert E Stamey III 990612 Back -Up ORC Name: Alan D Robinson 990618 Additional Back -Up ORC Name(s) and Russel Lanford 985166 Certification Number(s): M. COLLECTION SYSTEM PERMIT COMPLIANCE QUESTIONS: For new application please reference the attached draft permit in answering these questions. Any compliance dates needed will be put into the permit. For conditions not listed, compliance dates are not typically offered. Permit Condition Current Compliance? If no, Indicate a Compliance Date Typical Compliance Schedule I(3) — Grease ordinance with legal authority to inspect/enforce x❑ Yes ❑ No 12 —18 mo. . 1(4) — Grease inspection and enforcement program x❑ Yes ❑ No 12 —18 mo. I(5) — Three to five year Capital Improvement Plan. x❑ Yes ❑ No 12 —18 mo. 1(8) — Pump station identification signs. x❑ Yes ❑ No 3 mo. I(10) — Functional and conspicuous audible and visual alarms. x❑ Yes ❑ No 3 — 6 mo. II(5) — Spare pumps for any'station where one pump cannot handle l2eak flows alone (in a duplex station. the 2°d pump is the spare if pump reliability is met). x❑ Yes I� N — 9 mo_ II(7) — Accessible right -of --ways and easements. x❑ Yes ❑ No 6 —12 mo. 11(9) — Spill response plan with Items 9 (a — h). x❑ Yes ❑ No 3 mo. Other comments: FORM: CSA 10/05 Page 2 Applicant's Certification: Note. 15A NCAC 2T .0106(b) requires an authorized individual to sign this application form. In the case of corporations, signature is required by a principal executive officer of at least the level of vice president, or his duly authorized representative. In the case of a municipal, state, or other public entity, a signature is required by either a principal executive gfcer, ranking elected qfflcial or other duly authorized employee. Duly authorized employee's must provide proof from the principal executive officer or ranking elected oIcial that they have been authorized to sign this application. Public Works I, Richard Canipe, attest that this application for Town of Spruce Pine has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: **END OF FORM CSA 10105** FORM: CSA 10105 Page 3 Town of Spruce Pine, NC Attachment A for Condition V (4) Permit # WQCS00091 High Priority Lines Main interceptor parallel to North Toe River Line from Shannon Drive to WWTP under Toe River Collection line from East side of Town under Toe River Town of Spruce Pine, North Carolina Budget Ordinance Be it Ordained by the Town Council of the Town of Spruce Pine, North Carolina: Section I The following amounts are hereby appropriated in the General Fund for the operation of the Town Government and its activities for the fiscal year beginning July 1, 2012 and ending June 30, 2013, in accordance with the chart of accounts established for the town. General Government 182,322 Public Safety 910,001 Transportation 409,730 Environmental Protection 65,271 Cultural and Recreational 247,808 Cemetery 18,776 Economic Development 74,400 Revolving Loan 528 Total Expenditures 1,908,836 It is estimated that the following revenues will be available to the General Fund for the fiscal year beginning July 1, 2012 and Ending June 30, 2013. Ad -Valorem Taxes 849,941 Other Taxes 698,987 Unrestricted Intergovernmental Revenue 8,064 Restricted Intergovernmental Revenue 89,003 Licenses and Permits 5,827 Sales and Services 40,128 Investment Earnings 2,036 Other Revenues 27,597 Revolving Loan 13,567 Fund Balance Appropriated 173,686 Total Estimated Revenues 1,908,836 Section II The following amounts are hereby appropriated to the Water & Sewer Enterprise Fund for the fiscal year beginning July 1, 2012 and ending June 30, 2013. Administration & Plant Operation 954,173 Debt Service 289,21.0 Water Operations 452,367 Sewer Operations 340,777 Total Expenditures 2,036,527 It is estimated that the following revenues will be available to the Water & Sewer Enterprise Fund for the fiscal year beginning July 1, 2012 and ending June 30, 2013. Water Charges 1,218,987 Sewer Charges 785,504 Tap Fees 15,445 Availibility Fees 0 Penalties & Service Charges 12,063 Miscellaneous Revenues 4,127 Investment Earnings 401 Retained Earnings 0 Total Estimated Revenues 2,036,527 Town of Spruce Pine Water & Sewer Pump Stations Description Beaver Creek SPS Prison #1 SPS Prison #2 SPS Burleson Hill SPS —6eeust A-ve SPS �i• Feldspar SPS Carters Ridge SPS Pine Branch SPS Sparks Road SPS Sullins Branch SPS Sunnybrook SPS Duncan Street SPS Henredon SPS Mitchell High School SPS Type S S S S S S S S S S S S S Pumps 2 2 2 2 2 2 2 2 2 2 1 2 2 HP 20 50 30 30 8 50 3 3 5 11 2 10 30 GPM Mfgr 900 Fairbanks 410 Fairbanks 410 Fairbanks 200 Fairbanks 100 Fairbanks 200 Fairbanks 175 Fairbanks 50 Hydromatic 50 Hydromatic 50 Hydromatic 100 Fairbanks 50 Fairbanks 300 Fairbanks 90 Keen Const Concrete Concrete Concrete Concrete Concrete Concrete Concrete Concrete Concrete Concrete Concrete Concrete, Concrete Concrete ' 1 r Town of Spruce Pine — Fats, Oils and Greases Control Ordinance A. Scope and Purpose To aid in the prevention of sanitary sewer blockages and obstructions from contributions and accumulation of fats, oils, and greases into said sewer system from industrial or commercial establishments, particularly food preparation and serving facilities. B. Definitions 1. Fats, Oils, and Greases. Organic polar compounds derived from animal and/or plant sources that contain multiple carbon chain triglyceride molecules. These substances are detectable and measurable using analytical test procedures established in 40 CFR 136, as may be amended from time to time. All are sometimes referred to herein as "Grease" or "Greases". 2. Grease Trap or Interceptor. An approved device for separating and retaining waterborne Greases and Grease complexes prior to the wastewater exiting the trap and entering the sanitary sewer collection and treatment system. These devices also serve to collect settable solids, generated by and from food preparation activities, prior to the water exiting the trap and entering the sanitary sewer collection and treatment system. Grease Traps and Interceptors are sometimes referred to herein as "Grease Interceptors". 3. Cooking Establishments. Those establishments engaged in activities of preparing, serving, or otherwise making available for consumption foodstuffs and that use one or more of the following preparation activities: cooking by frying (all methods), baking (all methods), grilling, sauteing, rotisserie cooking, broiling (all methods), boiling, blanching, roasting, toasting, or poaching. Also included are infrared heating, searing, barbecuing, and any other food preparation activity that produces a hot, non -drinkable food product in or on a receptacle that requires washing. Such establishments include, but are not limited to, restaurants, cafeterias, extended care facilities, school cafeterias (public and private), and daycare facilities where meals for more than six (6) children are prepared, served or otherwise made available for human consumption. 4. Non -Cooking Establishments. Those establishments primarily engaged in the preparation of precooked foodstuffs that do not include any form of cooking. These include cold dairy and frozen foodstuffs preparation and serving establishments. 5. Minimum Design Capability. The design features of a Grease Interceptor and its ability or volume required to effectively intercept and retain Greases from grease -laden wastewaters discharged to the public sanitary sewer. 6. User. Any person, including those located outside the jurisdictional limits of the Town, who contributes, causes or permits the contribution or discharge of wastewater into the POTW, including persons who contribute such wastewater from mobile sources, such as those who discharge hauled wastewater. C. Grease Interceptor Maintenance. Record Keenine. and Grease Removal 1. Grease Interceptors shall be installed by Users as required by the Public Works Director or his designee. Grease Interceptors shall be installed at the User's expense, when such User operates a Cooking Establishment. Grease Interceptors may also be required in non -cooking or cold dairy and frozen foodstuffs establishments and other industrial or commercial establishments when they are deemed necessary by the Director of Public Works/Waste Water Superintendents for the proper handling of liquid wastes containing Grease. No User shall allow wastewater discharge concentration from subject Grease Interceptor to exceed 325 milligrams per liter, as identified by method EPA Method 1664 or 275 milligrams per liter, as identified by EPA method 413. All Grease Interceptors shall be of a type, design, and capacity approved by the Public Works Director/Waste Water Superintendents or his designee and shall be readily and easily accessible for User cleaning and Town inspection. All such Grease Interceptors shall be serviced and emptied of accumulated waste content as required in order to maintain Minimum Design Capability or effective volume of the Grease Interceptor, but not less often than every thirty (30) days. Users who are required to pass water through a Grease Interceptor shall: a. Provide for a minimum hydraulic retention time of twenty-four (24) minutes at actual peak flow or 12 minutes at the calculated theoretical peak flow rate as predicted by the Uniform Plumbing Code fixture Approved 01/09/2006 Town of Spruce Pine — Fats, Oils and Greases Control Ordinance criteria, between the influent and effluent baffles with twenty (20) percent of the total volume of the Grease Interceptor being allowed for sludge to settle and accumulate, identified hereafter as a "sludge pocket". b. Remove any accumulated Grease cap and sludge pocket as required, but at intervals of not longer than thirty- (30) days at the Users expense. Grease Interceptors shall be kept free of inorganic solid materials such as grit, rocks, gravel, sand, eating utensils, cigarettes, shells, towels, rags, etc., which could settle into this pocket and thereby reduce the effective volume of the Grease Interceptor. c. Accept the following conditions: If any skimmed or pumped wastes or other materials removed from Grease Interceptor are treated in any fashion onsite and reintroduced back into the Grease Interceptor as an activity of and after said onsite treatment, the User shall be responsible for the attainment of established Grease numerical limit consistent with and contained in (C)(1) on all discharges of wastewater from said Grease Interceptor into the Town of Spruce Pine sanitary sewer collection and treatment system. d. The User is required to ensure that all waste material removed from grease traps and interceptors are disposed of in a manner that complies with all federal, state and local statutes, rules regulations, policies and ordinances. e. The User shall maintain a written record of trap maintenance for three (3) years. All such records will be available for inspection by the Town at all times. f. Operate the Grease Interceptor in a manner so as to maintain said device such that attainment of the grease limit is consistently achieved. "Consistent" shall mean any wastewater sample taken from said Grease Interceptor shall be subject to terms of numerical limit attainment described in (C)(1). If an establishment desires, because of documented space constraints, an alternate to an out--of--building Grease Interceptor, the request for an alternative location shall contain the following information: 1. Location of Town sewer main and easement in relation to available exterior space outside building 2. Existing plumbing at or in a site that uses common plumbing for all services at that site. g. Understand and agree that: The use of biological additives as a Grease degradation agent is conditionally permissible, upon prior written approval by the Director. Any establishment using this method of Grease abatement shall maintain the trap or interceptor in such a manner that attainment of the Grease wastewater discharge limit, as measured from the trap's outlet, is consistently achieved. h. Understand and agree that: The use of automatic Grease removal systems is conditionally permissible, upon prior written approval by the Director of Public Works/Wastewater Superintendent, of the Town of Spruce -Pine,-and-the A4it-hell County Department shment-using tWs e,quipment shall-ep=te the system in such a manner that attainment of the Grease wastewater discharge limit, as measured from the unit's outlet, is consistently achieved. i. Understand and agree that: The Director of Public Works/Wastewater Superintendent reserves the right to make determinations of Grease Interceptor adequacy and need, based on review of all relevant information regarding Grease Interceptor performance, facility site and building plan review and to require repairs to, or modification or replacement of such traps. j. Upon the prior written approval of the Public Work Director, non -cooking establishments may be exempted from the requirements of this ordinance after an inspection of the subject premises and submission of adequate supporting documentation, as deemed necessary in the sole and absolute discretion of the Public Works Director. At a minimum, such supporting, documentation shall include: blue prints at the subject premises, and a full and detailed list of all potential sources of grease at the subject premises. Approved 01/09/2006 Town of Spruce Pine — Fats, Oils and Greases Control Ordinance k. Grease traps and interceptors may also be required in other facilities, as deemed necessary by the Town's designated Enforcement Official or Public Works Director. Impact and (ii) such overflow, spill, leak or other event may be attributed in part or in whole to a particular User, then the Town will seek enforcement action under the Sewer Use Ordinance, and/or the Pretreatment Enforcement Plan. For purposes of this section and overflow, spill, leak or other event shall be deemed to have an environmental impact when (i) such overflow or other event in voices and amount of wastewater equal to or in excess of one thousand (1000) gallons, or (ii) any amount of wastewater reaches any body of surface water. I. No non -grease laden sources are allowed to be connected sewer lines intended for Grease Interceptor service. m. Users shall supply (i) an adequate sampling point down stream of grease trap or interceptor, prior to mixing with other sanitary flows, and (ii) an accessible entry into each chamber of the grease trap or interceptor. The minimum requirement for the sampling point shall be a four -inch (4") vertical clean out. n. Access manholes, with a minimum diameter of 24 inches, shall be provided over each chamber and sanitary tee. The access manholes shall extend at least to finished grade and be designed and maintained to prevent water inflow or infiltration. The manholes shall also have readily removable covers to facilitate inspection, Grease removal, and wastewater sampling activities. All Manhole Construction shall conform to the Town of Spruce Pine's Specifications. o. Users shall empty and service grease traps and interceptors to comply with the perform aces criteria in Section C (1) of this ordinance as often as necessary, but in any event no longer than every thirty (30) days. Under the counter types of grease traps and interceptors shall be cleaned at least daily, and shall comply with the performance criteria in Section C of this ordinance. There shall be no reintroduction of wastewater back into the grease trap or interceptor unless and until reintroduction of wastewater back into the grease trap or interceptor unless and until said wastewater has been proven to contain 325 mg/1 or less of grease: Under no circumstances shall the sludge or scum layer be reintroduced or discharged into the Town's wastewater collection system or POTW D. Enforcement 1. No later than one (1) year after adoption of this ordinance, all users shall install grease traps or interceptors designed to limit the introduction, contribution and discharge of greases into the Town's wastewater collection system, or POTW. Grease traps and interceptors with appropriate sampling or inspection points shall be installed at the User's expense whenever any user operates a commercial establishment, industrial establishment, or a cooking establishment, or when required by the Director of Public Works. Grease traps and interceptors must have a minimum capacity of one thousand (1000) gallons or more as required to a ect a grease concentration maximum of 325 1n . — 2. Except as provided herein, for a period of one year following adoption of this Ordinance, although installation of Grease Interceptors will be required to be installed, no enforcement actions will be taken under this Ordinance for failure to achieve limits on Grease discharges from Grease Interceptors. 3. If an obstruction of a Town sewer main(s) occurs that causes a sewer overflow to the extent that an impact on the environment is realized and that said overflow or failure of the sanitary sewer collection system to convey sewage can be attributed in part or in whole to an accumulation of Grease in the Town's sewer main(s), the Town of Spruce Pine will take appropriate enforcement actions, as stipulated in the Town's Ordinance, against the generator or contributor of such Grease. E. Penalty & 52.050 Any Person, Firm or Corporation violating any provisions of the Fats, Oil and Grease control Ordinance shall be subject to a Civil penalty not to exceed $1,000 per day plus costs outlined in 52.050 E-2 and 3, as set forth in the Fats, Oil and Grease (FOG) Enforcement Matrix. Approved 01/09/2006 Town of Spruce Pine — Fats, Oils and Greases Control Ordinance a. A citation for said civil penalty shall be issued by the Town Manager. b. Each Citation for a civil penalty must be paid within the specified number of days on the citation after issuance. c. Each and every day that the -violation continues in violation of any provision of the Fats, Oil and Grease control Ordinance shall be a separate and distinct offense. 2. In addition to the Enforcement Matrix the violator shall be responsible for the reimbursement to the Town of Spruce Pine of all expenses that the town incurs due to the violation. These expenses include but are not limited to equipment cost, material cost, labor cost, for site remediation and cost recovery of a sanitary sewer overflow. 3. The violator of shall also be responsible for all costs associated with a public or private penalty against the town due to any fats, oils, and grease ordinance violation. Approved 01/09/2006 Town of Spruce Pine, North Carolina Wastewater Collection System Spill Response Plan (Communications, Assessment and Response Procedures) This plan is to be implemented in the event of a spill or overflow of the Wastewater Collection System. The plan is intended to allow response by key personnel within sixty (60) minutes of a reported spill. INITIAL RESPONSE Spill reported to or detected by a Collection System Operator. Wastewater Collection Operator will make preliminary assessment of the spill site within the first fifteen (15) minutes after the spill is first reported unless Maintenance Personnel are already available on site. Public Utilities Representative or Wastewater Collections Operator makes contact with key personnel from attached list within the first fifteen (15) minutes of a reported spill beginning with and continuing through the key personnel list until positive contact is made. Preliminary assessment information made available to responding personnel and instructions provided to Public Utilities Representative or Collections System Operator is required. Key Personnel reach spill site and continue assessment as required, and described in the containment and source control section of this plan. Key Personnel begin renewal action to eliminate the cause of the obstruction and/or system failure as outlined in the containment and source control diction of this plan. POST SPILL RESPONSE After containment is achieved, the Division of Water Quality must be contacted as soon as possible, but no later than twenty-four (24) hours after initial detection if. The spill has reached the surface waters; or the spill exceeds one thousand (1000) gallons. ANY SPILLS EXCEEDING 1000 GALLONS OR REACHES ANY SURFACE WATER MUST BE REPORTED WITHIN TWENTY-FOUR (24) HOURS TO DWQ. Spills that are fully contained, removed quickly and are less than one thousand (1000) gallons are not required to be reported to DWQ. A spill report form should be attached to this plan and filled out and kept on file. KEY PERSONNEL CONTACT NUMBERS CONTACT / TITLE TELEPHONE Elbert Stamey Res. (828)765-2655 Public Works Director Cell (828)385-0448 Roger Carpenter Res. (828)765-8724 Public Works Supervisor Richard Canipe Res. (828)765-2351 Town Manager Cell (828)766-6915 Russell Lankford Plant (828)765-3011 Project Manager — American Water Cell (828)385-1030 Spruce Pine Wastewater Plant (828)765-3011 Spruce Pine Town Hall (828)765-3000 SOURCE CONTROL AND CONTAINMENT PROCEDURE Depending on the nature of the spill or overflow, the initial assessment should initiate the priority of source control and/or containment. If the source can be isolated through valves, plugs or other methods, the flow should be discontinued immediately or reduced to the least event possible. If pumps are not operating the electrical panels should first be inspected to determine if power has been cut off at the breaker. If so, power should be restored to the pumps. Containment methods will typically include the use of sand or dirt of some description to build dikes on both land and at any potential surface waters or the use of a backhoe to construct a containment pit to prevent spillage from reaching surface waters. In ascertaining the cause, several potential factors should be considered in the cause of pump station overflow. Is the pump station receiving external power? Are the pumps receiving power from the breaker panel? Is the pump straining to work or not responding? Is the impeller obstructed? Is the motor burnt? After the above questions have been answered, a proper response can be formulated. If the above problem is electrical and cannot be rectified with the in-house personnel, immediately initiate contact with the electrical contractor listed on the Contractors and Vendors List. - e _ contact1 emergMey­ management from the attached Contractors and Vendors List. If the problem is mechanical in nature, collect parts from maintenance shop and initiate repairs. If parts are not in inventory, immediately contact and order parts to be delivered as soon as possible from vendors listed on the Contractors and Vendors List. In the event of a sewer blockage causing a manhole overflow, immediately jet out line, removing blockage with sewer jetting machine. CONTACT LIST FOR CONTRACTORS AND VENDORS Plumbing, Trenching and Digging Phillips Grading (828)765-9296 Sewer Pump Trucks Mayland Septic Company (828)765-9715 (828)765-1183 (cell) Electrical Contractor McKinney Electric (828)765-7910 Electrical Company Progress Energy (800)419-6356 French Broad Electric (800)222-6190 Parts/Equipment RESPONSE EQUIPMENT Backhoe Pressure Washer Sewer Pipe & Fittings Safety Equipment Portable Pump Portable Generator & Lights SUPPLIES Lime, Straw, Chlorine, Rubber Gloves, Boots, Goggles, Mask OUTFALL Put up warning tape "DANGER — DO NOT ENTER" around S.S.O.. site. In an open are, lime (powder) heavily and till. Repeat the procedure to ensure contact of all affected areas. Broadcast seed and straw. In the area where there is undergrowth of small trees, wash the area with doses of water. Continue with the water until no waste remains. Wait twelve (12) hours, and then lime the area heavily, being sure lime does not enter any surface waters. NOTE: Do not lime if the weather forecast is predicting rain. IN CITIZENS YARD Till the entire area if possible; apply lime and follow-up with the seed and straw. If the waste is not visible apply the lime and two (2) inches of topsoil and mix thoroughly. Apply lime lightly, broadcast seed and straw. ON ASPHALT OR CONCRETE Set up containment at/or near the storm drainage system; do not let the spill enter the storm drainage system. Put up black tape or red "DANGER — DO NOT ENTER" around the S.S.O. area. Spread lime on spillage and sand (or equivalent material) to a depth of one (1) inch. Let This stand ne lour, sweep "sI nd up. ir moisture or grease -is still present, repeat the procedure. After removing the contaminated material, wash down the area with high water pressure and sodium hypochlorite (bleach). Pump this back into the sewer system. Dispose of sand properly. If the spill goes into the storm drainage system, refer to any receiving water procedure. SURFACE WATERS AFFECTED BY SPILL (Stream or Creek Waters 1. Take conductivity reading of the affected surface waters in order to determine the proper placement of the dam. -The dam needs to be constructed near a manhole or at a location that is accessible to the jet/vacuum truck. Placement of the dam should be at a point where the lowest conductivity reading is measured if possible. Build hydrant water without dam failure. Station two at the dam that are capable of handling creek overflow. Use one pump for a backup. Have a backhoe at the site with extra material at all times so dam can be rebuilt if a breach occurs. Pump effluent from the dam into the manhole. 2. If rip rap is in creek, wash down with high water pressure until there is no waste residue remaining on/or within rip rap structure. 3. Put up warning tape, black or red "DANGER — DO NOT ENTER" from the S.S.O. site and at 400-foot downstream intervals until reaching the pump site. Bring the samples to the Wastewater Treatment Plant. Pull samples every twenty- four (24) hours until fecal-coliform readings less than 500 colonies are obtained. 4. If sludge enters surface waters, broom creek bottom and sides until there is no sludge residue remaining. 5. If surface waters flow into a body of water used for recreation, and/or drinking, notify the affected county and local officials as soon as the problem is discovered. Facility information NPDES permit #: NCO021423 Mitchell County Facility name: Town of Spruce Pine WWTP WWTP class: III WWTP type: 2.0 MGD (phased permit 0.5 MGD .& 2.0 MGD). WWTP .consisting of: US Filter Rex III (Envirex) ® mechanically cleaned bar screen (in operation since 1998 - needs replacing); potable water hydrant at influent (for wash down water) (needs repair or replacement); (screenings disposal - GDS. pick-up 2/mo to landfill); influent pump station with duplex 1111 gpm pumps with audible high water alarm and autodialer; Eutek Teacup ® headworks grit removal system; (grit disposal - GDS pick-up every 60 days to landfill); (trickling filter - out of service); Milltronics HydroRanger ® influent ultrasonic flow meter; Hach Sigma 900 ®'refrigerated composite sampler; Siemens Orval ®,three concentric ring oxidation ditch with four 40 HP rotary aerators; circular clarifier (# 1- out of service) dual 55 ft dia circular clarifiers; (#2 - in service; #3 clarifier - out of service); sludge pump station with duplex 1389 gpm wet well pumps; gas chlorine feed system (uses 150 # cylinders); baffled chlorine contact basin (converted primary clarifier); Wallace and Tierman Acutec 35 sulfur dioxide gas injection dechlorination feed system (uses 150 # cylinders); dechlorination basin; American Sigma ® refrigerated effluent composite sampler; (anaerobic sludge digestor - out of service); aerobic sludge digestor with. dual 25 HP floating aerators (converted one old ASB, other one never converted); 1.0 meter Ashbrook Klampress ® belt filter press (- 20% solids); polymer feed system with Brennfloc CP622 ® (cationic); 3 sludge drying beds; 300. KW diesel Spectrum 3000S emergency generator with - automatic transfer switch (Blue Ridge. Standby Power); 90 degree v-notch weir; and Endress-Houser ® ultrasonic flow measuring equipment with totalizer and circular chart recorder. Annual Average Flow: 0.306 MGD in 2008; 0.274 MGD in 2009; 0.291 in 2010 Maximum Daily Flow: 0.430 in 2008; 0.410 in 2009; 0.453 in 2010 A to C: Authorization to Construct issued 8-13-2007 for a new 1.0 meter belt filter press (in operation in June 2008). A to C for new plant issued 11-4-1996. New oxidation ditch WWTP on-line 8-29-1998. Collection System: WQCS00091 Class.11 Consists of 1192 sewer connections (as of 5-3-2011) serving a population of — 2050. There are — 30 miles of gravity- sewer and — 2.42 miles of force main (-171,178 ft total).. There are 13 duplex pump stations: none have SCADA, 4 have telemetry, 10 have dual high. water alarms, and 5 have diesel emergency generators on -site. The fuel vender is. Tri-Co Oil Company (Spruce Pine). The equipment service contactor is Blue Ridge Standby Power (Marion). The generators (self -tests weekly) are located at the following pump station locations: Beaver Creek pump station - 60 KW - Kohler Burleson Hill pump station - 75 KW - Generac Carter's Ridge pump station -100 KW - Generac DOC Prison #1 pump station - 80 KW - Onan DOC Prison # 2 pump station - 60 KW - Generac Ten percent (17,118 ft.) of the system is required to be cleaned annually.. There were 17,550 feet cleaned in 2010. There have been 10,220 feet cleaned as of 4-28-2011. During the next year, Oak and Locust Street are scheduled for cleaning. There are plans for the construction and operation (— 12-31-2011) for an additional - 2 miles of gravity sewer, — 2 miles of force main and two new lift stations to connect the Mitchell -County High School (in Ledger). This will eliminate the discharge of NPDES permit # NC0066737 which is -a 0.0144 MGD WWTP consisting of: two septic tanks; dosing tank with dual alternating pumps; dual surface sand filters; 20 gpm UV disinfection; and effluent aeration tank. ' Pretreatment Program: yes - modified -1 CIU - Categorical Ind. User: BRP US, Inc. (Bombardier Motor Co) - manufactures aluminum motors - 18,000 gpd w/ 2 discharges: chrome conversion line and casting line) Sludge Management: WQ0002349 Land Application of Residuals The sludge drying beds have not been used in several years, nor has the land application site been used in several years. Sludge is dewatered utilizing a cationic polymer and.1.0 meter Ashbrook Klampress @ belt filter press. The belt press is operated 4-5 days per week. The dried sludge is hauled by E. Luke Green Co. to the Iris Glen Landfill, located in Johnson City, TN. Toxicity testing: 6..6% for Ceriodaphnia (Qtrly: Feb, May, Aug, Nov) Passed 19 of 19 tests from Feb 2002 to 5-2006. WWTP Location: 909 Creed Pitman Road, northeast of Spruce Pine Responsible official: Richard Canipe Responsible "'s title: Town Manager www.sprucepine-nc.gov Official's location: 106 Highland Avenue, Spruce Pine 28777 Mailing address: PO Box 189; Spruce Pine, NC 28777 Phone numbers 828-765-3000 Richard Canipe — Town Manager @ Town Hall 828-766-6915 " - cell 828-765-3005 Elbert E Stamey III — Public Works Director 828-765-3014 "" — fax & Collection System - ORC 828-765-6521 _ Alan Dale Robinson — Coll. Sys. back-up ORC Frank Henline — Am. Water — part-time Bob Haller — Am. Water — belt press & coll. sys. 828-765-3007 Darrell J. Graham, ORC — @ WWTP 828-765-3007 " — fax (same #) - @ WWTP 828-385-1020 " — cell (digraham(@-amwater.com) 828-765-2767 " - home 828-385-1030 Russell Lankford — cell — Am. Water — proj. mgr. 828-765-3011 Water Plant — ORC Phillip Burleson;— Lab Supervisor— Am. Water Operator information WWTP ORC contractor: American. Water (www.amwater.com) WWTP ORO: Darrell J. Graham — Cert. # 25819 — WW-III 18028 Hwy 221 North; Marion, NO 28752 WWTP back-up ORCs: Phillip D..Burleson — Cert. # 9907 — WW=II Russell P. Lankford — Cert. # 29246 — WW-III Cert. # 085166 — CS -I (h) 551 Carter's Ridge Road; Spruce Pine, NO 28777-9773 Coll. Sys. ORC: Elbert E Stamey III — Cert. # 990612 - CS-1 (h) 8564 NO Hwy 183; Newland., NO 28657 Coil. Sys.. back-up ORC: Alan Dale Robinson — Cert. # 990618 — CS-1 (h) 56 Stream Road; Burnsville, NO 28714 Note: The collection system is a class CS -II. The ORC is- a class CS-1. Permit information Date issued: Expiration date: Stream information Stream: River. basin: Sub -basin: Hydrologic. Unit Code: Stream segment: 303d listed: Quad: March 1, 2011 February 28, 2016 North Toe River French Broad River Basin 04-03-06 06010108 7-2-(27.7)b yes Spruce Pine, NO Grid: D 10 NE Stream classification: C-Trout Drainage area sq mi: 133 Instream Waste Conc.: 6.6% Toxicity Testing Conc.: 6.6% for Ceriodaphnia (Qtrly: Feb, May, Aug, Nov) Annual Pollutant Scan: required Average stream flow: 266 cfs Summer 7Q1-0 cfs: 43.5 Winter 7Q10 cfs: 56 30Q2 cfs: 81.6 Other information Directions: From US Hwy 19 E in Burnsville, proceed to the Town of Spruce Pine. Turn left at the first stop light and proceed toward Bakersvil le. Turn right onto Meadowlark ,Road. Turn right onto Meadow Lane, then turn left onto Creed Pitman Road. Go to the bottom of the hill. As the payment ends to the left, take the gravel road along the river to the WWTP. NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor Richard Canipe Spruce Pine Collection System PO Box 189 Spruce Pine; NC 28777 Division of Water Quality Coleen H. Sullins Director January 6, 2010 Subject: System -Wide Wastewater Collection System Permit Expiration Date Permit Number WQCS00091 Spruce Pine Collection System Mitchell County Dear Richard Canipe: Dee Freeman Secretary Due to the recent enactment of SL 2009-406 (or SB 831), An Act to Extend Certain Government Approvals Affecting the Development of Real Property Within the State, the expiration date of all system -wide wastewater collection system permits is being extended by three (3) years. The new expiration date for the Spruce Pine Collection System Permit WQCS00091 is 03/31/13. A permit renewal application is due six months prior to the extended expiration date. If you have any questions or concerns, please contact me at (919) 807-6383 or via email [Deborah. Gore@ncdenr. gov] . Sincerely, Deborah Gore PERCS Unit Supervisor cc: Central Files Surface Water Protection Section Regional Office Supervisor 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 512 N. Salisbury St Raleigh, North Carolina 27604 Phone: 919-807.63001 FAX: 91H07-64921 Customer Service:1-877-&23-6748 Internet www.ncwaterquality.org An Equal Opportunity 1 Affirmafive Actlon Employer Nne orthCaro]ina Natunilly 11-14-07;10:03AM;Town of Spruce Pine ;828+765+3014 'water Pollution Control Systems ORC ,Designation Form WPCSOCC NCAC 15A.:08G .0201 General Information: Perinittee Owner/Officer Name: l o w N e �t S 2uo.E PI t4 �— �,.c fW ,�� Mailing Address: -?C7 %OI RC City tL�-k C-?- �� ,N State• d�Zip: -)- 17 Telephone N ber: (VCj -J 00 Signature. _ Date: ^ � " cY7 Raw RESEED ■■ min ■■EEWon rr■■■■..800...Ewee■r■■■.■.■■■0ir■■■■800rrrr■8080■■■ae� Facility Information: Facility: A) Aj. v_ 6p2 Permit Number 009F / . County: SUBMIT A, SEPARATE FORM FOR EACH TYPE OF'SYSTEM 1 Mark( Type of Facility Class (1 •- 4) • Class Wastewater Plant Spray irrigation _ N/A Physical/Chemical Land Application N/A Collection System L--- (d' /-) Subsurface N/A ■■■■■0800EE■■■■■�00ar■■■■■■rir�i�rr/■r■0000Err0rrrr■■■■■rwrrrr■■■■wr0rrs■■■i Operator in Responsible Charge: Print Name: G-/ D 'a-1`,-L E- 54Arvtg C 1 Social Security # : ci ' L{ — 0 a ` Certificate Type and Grade: j Certificate 9: 59 d (0 / 1- Work Telephone:(, (p U Signature Back -Up Operator in Responsible Charge: Print Name: _6 q,,Jl,) (� go 611V50,(J Social Security.# 07 4 3 " 11— 5 Certificate Type and Grade: _''' Certificate #::;� Work Telephone:( a-9) 7 (PIS Signature: { 4 . Mail or Fax to: WPCSOCC 1618 Mail Service Center Raleigh; N.C. 27699-1618. Fax: 919/733-1338 WAT p QUALITY SECTION A_SHEVILLE REGIONAL OFFI( Revised 10120,00 # 2/ 2 -7L& prre..r,i�°7i'-"9a'=4'.mva rrra�ar�r..g-z. ' Michael F. Easley, Governor 5 4 William G. Ross Jr., Secretary . joft .,..a olina ,eparmtrt7tao.Environment and Natural Resources _ Coleen H. Sullins, Director Division of Water Quality SURFACE WATER PROTECTION SECTION September 19, 2007 Richard Canipe Town of Spruce Pine Spruce Pine WWTP P.O. Box 189 Spruce Pine, NC 28777 SUBJECT: Privately -owned Collection Systems and Privately -owned Pump Stations Mitchell County Dear Mr. Canipe: As we have continued our evaluations of sewage collection systems management, it was recognized that there are a group of contributors that may not be informed of their individual responsibilities. In March 2000, the North Carolina Environmental Management Commission enacted rules related to sewage, collection systems. These rules are now found '�i'n the 'Worth Carolina Administrative Code 15 NCAC 2T .0403 for deemed permitted facilities. They include facilities with a privately -owned collection system that serve condominiums, apartments, mobile home parks, subdivisions, shopping centers, colleges, etc. that are tributary to larger municipally owned systems, yet are not owned or managed by the municipality. If you are aware of any such privately -owned collection systems, we would also like to be informed of their existence.. In addition, we would like to know where any privately -owned pump stations are located that are connected to your collection system. The type of information we are requesting is the facility name, location and contact person. If that system is in a state of disrepair or if you. have received complaints about it previously, please note that as well. ' Your attention to this request is most appreciated. We have been notified. of problems at some of these facilities in the past and have had a difficult time locating the responsible party to affect a repair to the problem. A response from you within 30 days would be very helpful as we try to ensure that all owners of collection systems are meeting the regulatory requirements of reporting spills and providing the proper operation and maintenance of their systems. Hopefully, this will also be beneficial to the operation of your municipal collection system. No thcarolina �ahrra!!r� North Carolina Division of Water Quality 2090 US Hwy 70; Swannanoa, NC 28778 Phone (828) 296-4500 Internet: www..ncwaterquality.org Customer Service 1-877-623-6748 FAX (828) 299-7043 An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper Town of Spruce Pine Page 2 of 2 September 19, 2007 Please list: 5 {1} privately -owned collection systems connected to your collection system a. facility name b. location c.. contact person d. status -of system (i.e. in a state of disrepair, etc.) e. complaints received (2) privately -owned pump stations connected to your collection system a. facility name b. location ' c. contact person d. status of pump station (i.e. in a state of disrepair, etc.) e. complaints received {3} or if applicable, indicate that you do not have any of these private collection systems or private pump stations connected to you collection system.- . You may fax this information to the attention of Roy Davis at 828-299-7043. Again, thank you for your assistance. Please contact Roy Davis or Keith Haynes at 828- 296-4500, should you have any questions regarding this request. Sincerel Roger C. Edwards, Regional .Supervisor Surface Water Protection Section Cc: DWQ - SWP - Central Files PERCS Unit .. Asheville Regional Office 10- 8-07; 11 :35AMJown of Spruce Pine 1828+765+3014 #F 4/ 5 Town, of Spruce P.iiie . Privately•Owned Server Pump..Stations Skyline Village Iru>< P.O. Box 37 12255-NC 226 A Little Swirieriand, NC 28749 Mr. Mike • ! hrift Kaluzia-Health Clinic 102 Ridge Road Spruce Fine, NC 28777 Value Print P.O. Box 249 . 7380 Nineteen E Hwy Spruce fine, NC 28777 Mr. Floyd Styles Phillip Franklin 124 Duke Franklin Road Spruce Pine, NC 28777 _ Mitchell Welding P.O.13ox 838 . 708.0 Nineteen EHwy Spruce Pine, NC 28777 Mr. Fred Stout Mitchell County 26 Crimson Laurel Circle 2097 Altapass Hwy Bakersville,'NC 28705 Mr. Chuck Vines Parton Land And Timber 251 Parton Rd Altapass Hury Rutherdfordton. NC 28139 i, 10- 8-07-,1.1-.35AM,Town of S'pruce Pine '828+765+3014 # 5/ 5 Value Print P.O. Box 249 7394 Nineteen E Hwy Spruce Pine, NC 28777 Mr., Floyd Styles B & W. Motors- 7464 Nineteen E Hwy Spruce Fine, NC-28777 Mr. Sherrill Ward Mr. Tim Moir 55 Lynn Street, - Spru�e Pine, NC 28777 10- 8-07;11:35AM-,Town of Spruce Pine i • P_O. Box 189 Spruce Pine, NC '28777 (828)765-3000 (828)765-3014 ;828+765+3014 F Town , Spruce To: f Sri skJ tit l ! t, From: f.M a l: 17 -701 4 Pages: a Phone: Date:. RQ: 1 C� N CC: Pww S TA -Zcciv4� 11 Urgent ❑ For Review ❑ Please Comment ❑ Please Reply- . ❑ Please RQGycle E , V E V OCT = 8 2007 i. WATER QUALITY SECTION ASHEVILLE REGIONAL OFFICE ....{4`r'�=�g1_yf�Lrig9 `:V1'C��r::JaYP yzit tl4�NY.i'allbtht:'Y: G••..aNf.H.� � , Or W. � Michael F. Easley; Governor C! r� William G. Ross Jr., Secretary � I n ,, r— North Carolina Department of Environment and Natural Resources oAlan W. Klimek, P.E. Director "-» Division of Water Quality -- The unit of government for whom you work has a collection system permit issued 'by the Division of Water Quality. It is our plan to conduct an annual Compliance Evaluation inspection of your program for operating, maintaining and improving your collection system. The inspection will consist of a review of ordinances, logs, budgets and inspections of sewers, equipment, pump stations and right-of-ways. The purpose of this letter is to tell you the type documents we would like for you to have present for the inspection and the order we would like to see them. 1. Grease reduction Public Education Program (established and documented) 2. Sewer Use Ordinance and Legal Authority for. Ordinance 3. Grease trap ordinance 4. Septic tank ordinance a. enforcement actions within the past 12 months 5. Capital Improvement Plan 6. Maintenance records for sewer lines 7. Records recording citizen complaints a Record of sewer system overflows (SSO's) a. sewer system overflow press releases and distribution list 9. Records documenting annual 'inspection of entire system 10. Records documenting semiannual inspection of high priority lines 11. Maintenance logs of major equipment used to clean and maintain sewer system including startup records of stand-by power units. 12. Pump station inspection, operation and maintenance logs 13. Right-of-way maintenance records 14. System cleaning records 15. Spill response action plan 16. Spare part inventory 17. System map 18. Sewer system budget including revenue 19. Most recent Collection System Annual Report 20. Your Collection System Permit. It is obvious that the purpose of the above, 'rather lengthy, list is to help you document what you are doing in the way of sewer system operations and maintenance. These same records allow us to determine compliance with permit requirements. We want to see a little fancy footwork when we conduct an inspection. If you use loose paper records we would like to see files organized, titled, complete, present and stacked neatly. If you use loose-leaf notebooks, dividers should be used between. sections. We are more than pleased to sit in front of a computer screen during the inspection if you use computer -based records. Behind a system of well organized records we obviously want a solid program of sewer operations, maintenance, rehabilitation and replacement leading to the reduction, as far as possible, in the occurrence of sewer system overflows and the amount of infiltration and inflow arriving at wastewater treatment plants. 1 Roy Davis, Environmental Engineer, Asheville Regional Office, 828-296-4659 Don Price, Wastewater Treatment Plant Consultant, Asheville Regional Office, 828-296-4500 TXTRMD, Collection system inspection 2 one - NorthCarolina North Carolina Division of Water Quality 2090 U.S.•Highway 70 Swannanoa, NC 28778 Phone (828) 296-4500 Customer Service Internet: h2o.enrstate.nc.us FAX (828) 299-7043 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled110% Post Consumer Paper 0� W.ATF9 -� Michael F. Easley, Governor O� pG %>_ William G. Ross Jr., Secretary N1hariolina Department of Environment and Natural Resources > r C. L. Gobble, Vice -Chairman Water Pollution Control. System Operators Certification Commission November 15, 2005 RICHARD CANIPE TOWN MANAGER TOWN OF SPRUCE PINES PO BOX 189 SPRUCE PINES NC 28777 Subject: Designations for Operator in Responsible Charge and Backup Operator in Responsible Charge Town of Spruce Pines Collections System Facility Classification:. Collections System -Grade 2 Permit No.: WQCS00091 Mitchell County Dear Mr. ,Canipe: The Division of Water Quality (DWQ) is in the process of reviewing and updating information contained in our database known as BIMS (Basinwide Information Management System). This review indicates that your facility, Town of Spruce Pines Collections System - Permit No.: WQCS00091 has not designated an operator as Operator in Responsible Charge (ORC) and at least one Backup Operator in Responsible Charge (backup ORC). Each classified facility must designate one ORC, who must hold a valid certificate of the same type as the system and a grade that is equal to or higher than the classification of the facility (CS-2), and a minimum of one backup ORC who must hold a valid certificate of the same type and no more than one grade lower than the classification of the facility (CS-1). You may designate multiple backup-ORC(s), but they must all hold valid certification at the appropriate grade. Failure to designate a properly certified ORC and Backup(s) constitutes a violation of the permit issued for this facility. Please complete and submit the enclosed form with designations by December 15, 2005 to: WPCSOCC, 1618 Mail Service Center Raleigh, NC 27699-1618.. Form may be faxed to (919) 733-1338. If you have any questions concerning this request, please contact me at (919) 733-0026 ext. 309 or reference our website at http://h2o.enr.state.nc.us/tacu. Sincerely, Jerry F. Rimmer, Supervisor Technical Assistance & Certification Unit cc: Central Files Technical Assistance & Certification Unit 1618 Mail Service Center, Raleigh, NC 27699-1618 DENR Customer Service' Center An Equal OpportunityAction,Employer Internet http://h2o.enr.state.nc.us/tacuAndex.html Telephone (919) 733-0026 Fax (919) 733-1338 Telephone 1 800 623-7748 50% recycled/10% post -consumer paper Nne orthCarolina Nahlrldy �OF \VN4A ,,�':c, >vy �; �,:,.,.-. Michael F. Easley, Governor �O G William-G, Ross Jr., Secretary North Carolina Department ofEnvironment and Natural Resources Alan W;Klimek, P.E., Director IIivision-of lity April 14, 2005 Richard Canipe aWATE 1 5 2005 Town Manager Town of Spruce Pine P.O. Box 189 I .j ALITY SECTION Spruce Pine, NC 28777 ASHEVILLE REGIONAL OFFICE Subject ..,Permit No. WQCS00091 Town of Spruce Pine Spruce Pine Wastewater Collection System Mitchell County Dear Mr. Canipe In accordance with your application received on May 31, 2002 and additional information received May 14, 2003 and March 17, 2005, we are forwarding herewith Permit No. WQCS00091 for the operation and maintenance of the subject wastewater collection system. This permit shall be effective from the date of issuance for a period of time not to exceed 5 years. This permit shall be subject to the conditions and limitations specified herein. It is your responsibility to thoroughly review this permit. Please pay particular attention to the monitoring and reporting requirements in this permit. Please pay particular attention to the monitoring and reporting requirements,in-this-permit=and-any-compliance-schedules-shown-in-bold-(Conditions 1-(4.).,_I-(7-), I (10), II (9))• For purposes of permitting, the collection system is considered to be any existing or newly installed system extension up to the wastewater treatment facility property or point of connection with a separately -owned sewer system. The collection system is considered all gravity lines, pump stations, force mains, low pressure sewer systems, STEP systems, vacuum systems, etc. and associated piping, valves and appurtenances that help to collect, manage and transport wastewater to a wastewater treatment plant under the Permittee's ownership or maintained and operated by the Permittee through a perpetual legal agreement. Satellite systems are systems tributary to the Permittee's collection system but those collection systems are not owned or maintained by the Permittee. The system description provided on Page 1 of this permit is meant to provide a general idea about the size of the system and may not be all inclusive of the collection system at the time of permit issuance or afterward. A release of wastewater from the wastewater collection system is referred to herein as a Sanitary Sewer Overflow (SSO). The evaluation of enforcement options after a SSO will be determined considering the criteria listed in condition 1 (2) (a) and I (2) (b) of the permit and all other relevant information available or requested of the Permittee. Compliance with all conditions of the permit as well as all statutes and regulations per to the collection system must be maintained or appropriate enforcement actions may be taken as noted in Condition A (3). Pretreatment, Emergency Response and Collection Systems Unit Internet http://h2o.enr.state.nc.us/ndpu One NorthCaTolina 1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone (919) 733-5083 Fax (919) 733-0059 V j'Q"1/ DENR Customer Service Center Telephone 1 800 623-7748 i/ An Equal Opportunity Action Employer 50% recycled/10% post -consumer paper A reportable SSO is a SSO greater than 1,000 gallons to the ground or a SSO of any amount that_ \\_- reaches surface water (including through ditches, --storm drains, etc.)-BeloW--is-the-procedure to use for �` reporting SSOs to the Division: a) Report by telephone to a Division of Water Quality staff member (not facsimile or voicemail) at your regional DWQ office during regular business hours (Monday to Friday, 8AM to 5PM) as soon as possible, but in no case more than 24 hours after the SSO is 'known or discovered. To report outside of regular business hours, call (800) 858-0368. b) Follow up the verbal report by sending a completed written report on the most current Division approved form within five days. To provide a uniform method for all systems covered under this permit and to provide useful and consistent information pertaining to SSOs, a new spill reporting form has been developed (October 2003). Form CS-SSO consists of two parts. Part I serves to provide to the Division the required information that has always been necessary. Part II serves as an area to provide a justification for the spill, as optional under Condition 1 (2) of your permit. Form CS-SSO can be downloaded from http://h2o.enr.state.nc.us/ndceu/ from the Collection Systems area. An NOV, civil penalty, and/or a moratorium on the addition of waste to the system may be issued if adequate justification for an SSO is NOT submitted to the regional office. In order to submit a claim for justification of an SSO,, you must use the Form CS-SSO with additional documentation as necessary. DWQ staff will review the justification claim and determine if enforcement action is appropriate. Please be advised that the information needed to justify a spill is very comprehensive. Begin using this form immediately to report SSOs from the collection system. Continue to use our old form for reporting bypasses at the wastewater treatment plant until further notice. The time frame for submittal of both Part I and Part II, if pertinent, is five days. Failure to abide by the conditions in this permit may subject the Permittee to enforcement action. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty days following the receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such.demands are made, this permit shall be final and binding. If you have questions regarding compliance contact your regional office or Jeff Poupart of the Pretreatment, Emergency Response and Collection Systems Unit of the North Carolina Division of Water Quality at (919) 733-5083 extension 527. If you need additional information concerning this permit, please contact Deborah Gore in the Pretreatment, Emergency Response and Collection Systems Unit at (919) 733-5083 extension 593. Sincerely, -�( Alan W. Klimek, P.E. cc. Mitchell Count��y Heap lth Depgrtmgnt ''Asheville Regional Office-Wa e Q.uglify:S-ection Technical Assistance and Certification Unit Water Quality Central Files Deborah Gore, PERCS Files PERMIT Ver.09/04 A reportable SSO is -a SSO greater'than 1,000 gallons to- the ground or a SSO of any amount that reaches surface water (including through ditches,, storm drains, etc.) Below is the procedure to use for reporting SSOs to the Division: a) Report by telephone to a Division of Water Quality staff member (not facsimile or voicemail) at your regional DWQ office during regular business hours (Monday to Friday, 8AM to 5PM). as soon as possible, but. in no case more. fhan 24 hours after the SSO is known. or discovered. To report outside of regular business hours, call (800) 858-0368. b) Follow up the verbal report by sending a completed written report on the most current Division approved form within five days. To provide a uniform method .for all systems covered under this permit and to provide useful and consistent information pertaining to SSOs, a new spill reporting form, has been developed (October 2003). Form CS-SSO consists of two parts. Part I serves to provide to the Division the required information that has always been necessary. Part II serves as an area to provide a justification for the spill, as optional under , Condition - 1 (2) of your permit. Form CS-SSO can be downloaded from http://h2o.enr.state.nc.us/ndceu/ from the Collection Systems area. An NOV" civil penalty, and/or 'a moratorium on .the ,addition of waste to the system may be issued if adequate justification for,an SSO is NOT submitted to the regional office. In order to submit a claim for justification of an SSO, you .must use the Form CS-SSO with additional documentation as necessary. DWQ staff will review the -justification claim and determine if enforcement -action is appropriate. -Please be advised that the information needed to justify a spill is very comprehensive. Begin using this form immediately to report SSOs from the collection system. Continue to' use our old form for reporting bypasses at the wastewater treatment plant until further notice. The time frame for submittal of both Part I and Part 11, if pertinent, is five days., Failure to abide by the conditions in this permit may .subject the Permittee to enforcement action. if any parts, requirements,, or limit ations'contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty days following the receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150E of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you -have questions regarding compliance contact your regional office or Jeff Poupart of the Pretreatment, Emergency Response and Collection Systems Unit of the North Carolina Division of Water Quality at (919) 733-5083 extension 527. If you need additional information concerning this permit, please contact Deborah Gore in the Pretreatment, Emergency Response and Collection Systems Unit at (919) 733-5083 extension 593. Sincerely, Alan W. Klimek, P.E. cc: Mitchell County Health Department Asheville Regional Office, Water Quality Section Technical Assistance'and Certification. Unit Water Quality Central. Files Deborah Gore, PERCS Files PERMIT Ver.09/04 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH SYSTEM -WIDE WASTEWATER COLLECTION SYSTEM PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO TOWN OF SPRUCE PINE MITCHELL COUNTY 103211aA operation and maintenance of a wastewater collection system consisting of, at the time of permit issuance, approximately 30 miles of gravity sewer, approximately 2.42 miles of force main, 13 duplex pump stations, and all associated piping, valves, and appurtenances required to make a complete and operational wastewater collection system to serve the Town of Spruce Pine and any deemed - permitted -satellite _ communities, ---pursuant to -=the —application -received on May 31-, 2002, and in conformity with the documents referenced therein and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until March 31, 2010 and shall be subject to the following specified conditions and limitations: I. PERFORMANCE STANDARDS The sewage and wastewater collected by this system shall be treated in the Town of Spruce Pine Wastewater Treatment Facility NCO021423 prior to being disposed into the receiving stream. This collection system permit will be referenced upon renewal or modification of your NPDES permit(s). 2. The wastewater collection system shall be effectively managed, maintained and operated at all times so that there is no SSO to land or surface waters, nor any contamination of groundwater. In the event that the wastewater collection system fails to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective actions, including actions that may be required by the Division of Water Quality (Division), such as the construction of additional or replacement sewer lines and/or equipment. The Director may take enforcement action against the Permittee for SSOs that must be reported to the Division as stipulated in Condition IV (2). This includes SSOs that were caused by severe natural conditions or exceptional events unless the Permittee demonstrates through properly signed, contemporaneous operating logs, or other relevant evidence that: PERMIT Ver.09/04 M a. The SSO was caused by severe natural conditions; there were no feasible alternatives to the SSO, such as the use of auxiliary treatment facilities,- retention of untreated wastewater, reduction of inflow and infiltration, use of adequate back-up equipment, or an increase in the capacity of the system. This provision is not satisfied if, in the exercise of reasonable engineering judgment, the Permittee should have installed auxiliary or additional collection system components, wastewater retention or treatment facilities, adequate back-up equipment or should have reduced inflow and infiltration; or b. the SSO was exceptional, unintentional, temporary and caused by factors beyond the reasonable control of the Permittee; the SSO could not have been prevented by the exercise of reasonable control, such as proper management, operation and maintenance; adequate treatment facilities or collection system facilities or components (e.g., adequately enlarging treatment or collection facilities to accommodate growth or adequately controlling and preventing infiltration and inflow);. preventive maintenance; or installation of adequate back-up equipment; The Permittee can submit a claim to the Division Regional Office that the SSO meets the criteria of this condition. The Permittee has the option of submitting this claim along with the spill report required by Condition IV (2) (i.e., within five days) in order to be considered for immunity from enforcement action. Form CS-SSO Part II, or most current Division approved form, shall be used for any claims. The Permittee has the burden of proof that the above criteria have been met. 3. The Permittee shall establish by ordinance its legal authority to require new sewers be properly constructed; to ensure proper inspection and testing of sewer mains and service laterals; to address flows from satellite systems and to take enforcement action as required by Condition 1 (4) . 4. The Permittee shall develop and implement an educational fats, oils and grease program targeted at both residential and non-residential users.' The Permittee shall also develop and implement an enforceable fats, oils and grease program for non-residential users under which the Permittee can take enforcement against users who have not properly installed, operated and maintained grease traps or grease interceptors as directed or otherwise violated the terms of the local ordinance pertaining to fats, oils and grease. The Permittee shall adopt a Grease Control Policy by July 1, 2005. A copy of the Policy documents shall be submitted to the Asheville Regional Office to show compliance with this schedule. 5. The Permittee shall adopt and implement a Capital Improvement Plan (CIP) to designate funding for reinvestment into the wastewater collection system infrastructure. The CIP should address the short-term needs and long-term "master plan" concepts. The CIP should typically cover a three to five year period and include a goal statement; description of the project area, description of the existing facilities, known deficiencies (over a reasonable period) and forecasted future needs. Cost analysis is integral to the CIP. 6. Existing overflow piping from manholes and pump stations, excluding piping to approved equalization structures, known or discovered after permit issuance shall be immediately removed or permanently capped. Plugged emergency pumping connections are allowable for portable pumping or rerouting without intentionally bypassing the wastewater treatment facility. 7. The Permittee shall maintain a contingency plan for pump failure at each pump station. If one of the pumps in a pump station containing multiple pumps fails, the process of repairing or replacing the pump shall be initiated immediately and the new parts or pump shall be installed as soon as possible. If the pump in a simplex pump station fails, it shall be replaced immediately. 2 PERMIT Ver.09/04 a. The SSO was caused by severe natural conditions; there were no feasible alternatives to the SSO, such as the use of auxiliary treatment facilities, retention of untreated wastewater, reduction of inflow and infiltration, use of adequate back-up equipment, or an increase in the capacity of the system. This provision is not satisfied if, in the exercise of reasonable engineering judgment, the Permittee should, have installed auxiliary or additional collection system components, wastewater retention or treatment facilities, adequate back-up equipment or should have reduced inflow and infiltration; or b. the SSO was exceptional, unintentional, temporary and caused by factors beyond the reasonable control of the Permittee; the SSO could not have been prevented by the exercise of reasonable control, such as proper management, operation and maintenance; adequate treatment facilities or collection system facilities or components (e.g., adequately enlarging treatment or collection facilities to accommodate growth or adequately controlling and preventing infiltration and inflow); preventive maintenance; or installation of adequate back-up equipment; The Permittee can submit a claim to the Division Regional Office that the SSO meets the criteria of this condition. The Permittee has the option of submitting this claim along with the spill report required by Condition IV (2) (i.e., within five days) in order to be considered for immunity from enforcement action. Form CS-SSO Part II, or most current Division approved form, shall be used for any claims. The Permittee has the burden of proof that the `above criteria have been met. 3. The Permittee shall establish by ordinance its legal authority to require new sewers be properly constructed; to ensure proper inspection and testing of sewer mains and service laterals; to address flows from satellite systems and to take enforcement action as required by Condition 1(4). 4. The Permittee shall develop and implement an educational fats, oils and grease program targeted at both residential and non-residential users. The Permittee shall also develop and implement an enforceable fats, oils and grease program for non-residential users under which the Permittee can take enforcement against users who have not properly installed, operated and maintained grease traps or grease interceptors as directed or otherwise violated the terms of the local ordinance pertaining to fats, oils and grease. The Permittee shall adopt a Grease Control Policy by July 1, 2005. A copy of the Policy documents shall be submitted to the Asheville Regional Office to show compliance with this schedule. ,5. The Permittee shall adopt and implement a Capital Improvement Plan (CIP) to designate funding for reinvestment into the wastewater collection system infrastructure. The CIP should address the short-term needs and long-term "master plan" concepts. The CIP should typically cover a three to five year period and include a goal statement, description of the project area, description of the existing facilities, known deficiencies (over a reasonable pe(od) and forecasted future needs. Cost analysis is integral to the CIP. 6. Existing overflow piping from manholes and pump stations, excluding piping to approved equalization structures, known or discovered after permit issuance shall be immediately removed or permanently capped. Plugged emergency pumping connections are allowable for portable pumping or rerouting without intentionally bypassing the wastewater treatment facility. The Permittee shall maintain a contingency plan for pump failure at each pump station. If one of the pumps in a pump station containing multiple pumps fails, the process of repairing or replacing the pump shall be initiated immediately and the new parts or pump shall be installed as soon as possible. If the pump in a simplex pump station fails, it shall be replaced immediately. 2 PERMIT Ver.09/04 The Permittee shall post a Contingency Plan for Pump Failure at each pump station by July 1, 2005. A copy of the Plan shall be submitted to the Asheville Regional Office to show compliance with this schedule. 8. Each pump station shall be clearly and conspicuously posted with a pump station identifier and an emergency contact telephone number at which an individual who can initiate or perform emergency service for the wastewater collection system 24 hours per day, seven days per week can be contacted. This emergency contact telephone number shall be coupled with instructions that the emergency contact should be called if the visual alarm illuminates, if the audible alarm sounds, or if an emergency is apparent. Pump station sites, equipment and components shall have restricted access, per 15A NCAC 2H .0219(h)(7). 10. Pump stations that do not employ an automatic polling feature (i.e. routine contact with pump stations from a central location to check operational status of the communication system) shall have both audible and visual high water alarms. The alarms shall be weather- proof and placed in a clear and conspicuous location. Permits issued for the construction of pump stations that included high water alarms in the description must maintain the alarms even if simple telemetry (i.e. notification of an alarm condition initiated by the pump station control feature) is installed. The Permittee shall install visual and audible alarms at all pump stations by July 1, 2005. 11. For all newly constructed, modified and rehabilitated pump stations, all equipment and components located within the pump station shall be corrosion-resistant'and components in close proximity of the pump station shall be sealed within a corrosion -resistant coating or encasement. 12. All construction and rehabilitation of the wastewater collection system (i.e., permitted or deemed permitted) shall be scheduled to minimize the interruption of service by the existing utilities. Construction and rehabilitation shall not result in the violation of Condition 1.2. of this permit. II. OPERATION AND MAINTENANCE REQUIREMENTS Upon classification of the collection system by the Water Pollution Control System Operators Certification Commission (WPCSOCC), the Permittee shall designate and employ a certified operator to be in responsible charge (ORC) and one or more certified operators) to be back-up ORC(s) of the facilities in accordance with 15A NCAC 8G .0201. The ORC shall visit the system within 24 hours of knowledge of a bypass, spill, or overflow of wastewater from the system, unless visited by the Back -Up ORC, and shall comply with all other conditions of 15A NCAC 8G .0204. 2. The Permittee shall develop and adhere to a schedule for reviewing all inspection, maintenance, operational and complaint logs. If the review process results in the identification of any recurring problem in the wastewater collection system, that cannot be resolved in a short time period, the Permittee shall establish a plan for addressing the problem(s). 3. The Permittee shall develop and adhere to a schedule for testing emergency and standby equipment. 4. The Permittee shall develop and implement a routine pump station inspection and maintenance program, which shall include, but not be limited to, the following maintenance activities: PERMIT Ver.09/04 L.:] a. Cleaning and removing debris from the pump station structure, outside perimeter, and wet well; b. Inspecting and exercising all valves; c. Inspecting and lubricating pumps and other mechanical equipment according to the manufacturer's recommendations; and d. Verifying the proper operation of the alarms, telemetry system and auxiliary equipment. For each pump station without pump reliability (i.e. simplex pump stations serving more than a single building or pump stations not capable of pumping at a rate of 2.5 times the average daily flow rate with the largest pump out of service), at least one fully operational spare pump capable of pumping peak flow shall be maintained on hand. The Permittee shall maintain on hand at least two percent of the number of pumps installed, but no less than two pumps, that discharge to a pressure sewer and serve a single building, unless the Permittee has the ability to purchase and install a replacement pump within 24 hours of first knowledge of the simplex pump failure or within the storage capacity provided in any sewer line extension permit 7. Rights -of -way and/or easements shall be properly maintained to allow accessibility to the wastewater collection system unless the Permittee can demonstrate the ability to gain temporary access in an emergency situation where existing land -use conditions do not allow the establishment and maintenance of permanent access. In this case, the Permittee shall continue to observe the lines visually, utilize remote inspection methods (e.g. CCTV) and use the opportunity of drier conditions to perform further inspections and necessary maintenance. 8. The Permittee shall assess cleaning needs and develop and implement a program for appropriately cleaning, whether by hydraulic or mechanical methods, all sewer lines. At least 10 percent of the wastewater collection system, selected at the discretion of the ORC, shall be cleaned each year. Preventative cleaning is not required for sewer lines less than five years old unless inspection otherwise reveals the need for cleaning or cleaning is required by a sewer line extension permit. 9. Adequate measures shall be taken to contain and properly dispose of materials associated with SSOs. The Permittee shall maintain a Response Action Plan that addresses the following minimum items: a. Contact phone numbers for 24-hour response, including weekends and holidays; b. Response time; c. Equipment list and spare parts inventory; d. Access to cleaning equipment; e. Access to construction crews, contractors and/or engineers; f. Source(s) of emergency funds; g. Site sanitation and clean up materials; and h. Post-SSO assessment. The Permittee shall adopt a Response Action Plan by July 1, 2005. A copy of the Plan shall be submitted to the Asheville Regional Office to show compliance with this schedule. 10. The Permittee, or their authorized representative, shall conduct an on -site evaluation for all SSOs as soon as possible, but no more than two hours after first knowledge of the SSO. 11. In the event of a SSO or blockage within the wastewater collection system, the Permittee shall restore the system operation, remove visible solids and paper, sanitize any ground area and restore the surroundings. 4 PERMIT Ver.09/04 a. Cleaning and removing debris from the pump station structure, outside perimeter, and wet well; b. Inspecting and exercising all valves; c. Inspecting and lubricating pumps and other mechanical equipment according to the manufacturer's recommendations; and d. Verifying the proper operation of the alarms, telemetry system and auxiliary equipment. For each pump station -without pump reliability (i.e. simplex pump stations serving more than a single building or pump stations not capable of pumping at a rate of 2.5 times the average daily flow rate with the largest pump out of service), at least one fully operational spare pump capable of pumping peak flow shall be maintained on hand. 6. The Permittee shall maintain, on hand at least two percent of the number of pumps installed, but no less than two pumps, that discharge to a pressure sewer and serve a single building, unless the Permittee -has the ability to purchase and install a replacement pump within 24 hours of first knowledge of the simplex pump failure or within the storage capacity provided in any sewer line extension permit 7. Rights -of -way and/or easements shall be properly maintained to allow accessibility to the wastewater collection system unless the Permittee can demonstrate the ability to gain temporary access in an emergency situation where existing land -use conditions do not allow the establishment and maintenance of permanent access. In this case, the Permittee shall continue to observe the lines visually, utilize remote inspection methods (e.g. CCTV) and use the opportunity of drier conditions to perform further inspections and necessary maintenance. The Permittee shall assess cleaning needs and develop and implement a program for appropriately cleaning, whether by hydraulic or mechanical methods, all sewer lines. At least 10 percent of the wastewater collection system, selected at the discretion of the ORC, shall be cleaned each year. Preventative cleaning is not required for sewer lines less than five years old unless inspection otherwise reveals the need for cleaning or cleaning is required by a sewer line extension permit. Adequate measures shall be taken to contain and properly dispose of materials associated with SSOs. The Permittee shall maintain a Response Action Plan that'addresses the following minimum.items: a. Contact phone numbers for 24-hour response, including weekends and holidays; b.- Response time; c. Equipment list and spare parts inventory; d. Access to cleaning equipment; e. Access to construction crews, contractors and/or engineers; f. Source(s) of emergency funds; g. Site sanitation and clean up materials; and h. Post-SSO assessment. The Permittee shall adopt a Response Action Plan by July 1, 2005. A copy of the Plan shall be submitted to the Asheville Regional Office to show compliance with this schedule. 10. The Permittee, or their authorized representative, shall conduct an on -site evaluation for all SSOs as soon as possible, but no more than two hours after first knowledge of the SSO. 11. In the event of a SSO or blockage within the wastewater collection system, the Permittee shall restore the system operation, remove visible solids and paper, sanitize any ground area and restore the surroundings. 4 PERMIT Ver.09/04 • III. RECORDS Records shall be maintained to document compliance with Conditions 1 (4), II (2) - II (4),11 (7) - II (8), IV (3) and V (1) -V (4). Records shall be kept on file for a minimum of three years. 2. The Permittee shall maintain adequate records pertaining to SSOs, and complaints for a minimum of three years. These records shall include, but are not limited to, the following information: a. Date of SSO or complaint; b. Volume of wastewater released as a result of the SSO and/or nature of complaint; c. Location of the SSO and/or complaint; d. Estimated duration of the SSO; e. Individual from the Division who was informed about the SSO and/or complaint, when applicable; f. Final destination of the SSO; g. Corrective actions; h. Known environmental/human health impacts resulting from the SSO; and i. How the SSO was discovered. 3: The Permittee shall maintain an up-to-date, accurate, comprehensive map of its wastewater collection system that also notes the locations where other wastewater collection systems become tributary. If a comprehensive map of the collection system has not been established, a rough sketch shall be drawn. The Permittee shall map approximately 10 percent of its existing collection system each year for the next ten years, or until complete, whichever is sooner. The comprehensive map shall include, but is not limited to: pipe size, pipe material, pipe location, flow direction, approximate pipe age, number of active service taps, and each pump station identification, location and capacity. 4. The Permittee shall maintain records of all of the modifications and extensions to the collection system permitted herein. The Permittee shall maintain a copy of the construction record drawings and specifications for modifications/extensions to the wastewater collection system for the life of the modification/extension. Information concerning the extension shall be incorporated into the map of the wastewater collection system within one year of the completion of construction. The system description contained within this permit shall be updated to include this modification/extension information upon permit renewal. IV. MONITORING AND REPORTING REQUIREMENTS 1. Any monitoring (including, but not necessarily limited to, wastewater flow, groundwater, surface water, soil or plant tissue analyses) deemed necessary by the Division to ensure surface water and groundwater protection will be established, and an acceptable sampling and reporting schedule shall be followed. 2. The Permittee shall verbally report to a Division of Water Quality staff member at the Raleigh Regional Office, at telephone number 919-571-4700 as soon as possible, but in no case more than 24 hours following the occurrence or first knowledge of the occurrence of either of the following: a. Any SSO and/or spill over 1,000 gallons; or b. Any SSO and/or spill, regardless of volume, that reaches surface water. PERMIT Ver.09/04 ft % Voice mail messages or faxed information is permissible but this shall not be considered as the initial verbal report. SSOs (and other types of spills) occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Per Condition 1 (2), Part II of Form CS-SSO (or the most current Division approved form) can also be completed to show that the SSO was beyond control. 3. The Permittee shall meet the annual reporting and notification requirements provided in North Carolina General Statute § 143-215.1 C. V. INSPECTIONS The Permittee or the Permittee's designee shall inspect the wastewater collection system regularly to reduce the risk of malfunctions and deterioration, operator errors, and other issues that may cause or lead to the release of wastes to the environment, threaten human health or create nuisance conditions. The Permittee shall keep an inspection log or summary including, at a minimum, the date and time of inspection, observations made, and any maintenance, repairs, or corrective actions taken by the Permittee. 2. Pump stations without Supervisory Control and Data Acquisition (SCADA) systems or telemetry shall be inspected everyday (i.e. 365 days per year). Pump stations equipped with SCADA systems or telemetry shall be inspected at least once per week. A general observation of the entire collection system shall be performed throughout the course of every year. 4. Inspections of all high priority lines (i.e. aerial line, sub -waterway crossing, line contacting surface waters, siphon, line positioned parallel to stream banks that are subject'to eroding in such a manner that may threaten the sewer line, or line designated as high -priority in a permit) shall be performed at least once per every six-month period of time. A list of high - priority lines is presented below. New high priority lines installed or identified after permit issuance are incorporated by reference and subject to this permit condition until permit renewal where they shall be referenced in writing. a. Main interceptor parallel to North Toe River b. Line from Shannon Drive to WWTP under North Toe River C. Line from north east side of Spruce Pine into the Beaver Creek Pump Station VI. GENERAL CONDITIONS This permit is not transferable. In the event that the Permittee desires to transfer ownership of the wastewater collection system or there is a name change of the Permittee, a formal permit modification request shall be submitted to the Division. The request shall be accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. Such request will be considered on its merits and may or may not be approved. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division in accordance with North Carolina General Statute § 143-215.6A through § 143-215.6C, and a sewer moratorium may be established. PERMIT Ver.09/04 Voice mail messages or faxed information is permissible but this shall not be considered as the initial verbal report. SSOs (and other types of spills) occurring outside normal business hours may also be reported to the Division of Emergency Management at telephone number (800) 858-0368 or (919) 733-3300. Persons reporting any of the above occurrences shall file a spill report by completing Part I of Form CS-SSO (or the most current Division approved form), within five days following first knowledge of the occurrence. This report shall outline the actions taken or proposed to ensure that the problem does not recur. Per Condition 1 (2), Part II of Form CS-SSO (or the. most current Division approved form) can also be completed to show that the SSO was beyond control. 3. The Permittee shall meet the annual reporting and notification requirements provided in North Carolina General Statute § 143-215.1 C. V. INSPECTIONS 1. The Permittee or the` Permittee's designee shall inspect the wastewater collection system regularly to reduce the risk of malfunctions and deterioration, operator errors,. and other issues that may cause or lead to the release of wastes to the environment, threaten human health or create nuisance conditions. The Permittee shall keep an inspection log or summary including, at a minimum, the date and time of inspection, observations made, and any maintenance, repairs, or corrective actions taken by the Permittee. 2. Pump stations without Supervisory Control and Data Acquisition (SCADA) systems or telemetry shall be inspected everyday (i.e. 365 days per year). Pump stations equipped with SCADA systems or telemetry shall be inspected at least once per week. 3. A general observation of the entire collection system shall be performed throughout the course of every year. 4. Inspections of all high priority lines (i.e. aerial line, sub -waterway crossing, line contacting surface waters, siphon, line positioned parallel to stream banks that are subject to eroding in such a manner that may threaten the sewer line, or line designated as high -priority in a permit) shall be performed at least once per every six-month period of time. A list of high - priority lines is presented below. New high priority lines installed or identified after permit issuance are incorporated by reference and subject to this permit condition until permit renewal where they shall be referenced in writing. a. Main interceptor parallel to North Toe River b. Line from Shannon Drive to WWTP under North Toe River C. Line from north east side of Spruce Pine into the Beaver'Creek Pump Station . VI. GENERAL CONDITIONS l . This. permit is not transferable. In the event that the Permittee desires to transfer ownership of the wastewater collection system or there is a name change of the Permittee, a formal permit modification request shall be submitted to the Division. The request shall Abe accompanied by documentation from the parties involved, and other supporting materials as may be appropriate. Such request will be considered on its merits and may or may not be approved. 2. Failure to abide by ther conditions and limitations contained in this permit may subject the Permittee to an enforcement action by. the Division in accordance with North Carolina General Statute § 143-215.6A through § 143-215.6C, and • a sewer moratorium may be established. ` PERMIT Ver.09/04 i 3. The issuance of this permit does not exempt the Permittee from complying with any and all statutes, rules, regulations, or ordinances that may be imposed by other government agencies (i.e., local, state, and federal) having jurisdiction, including but not limited to applicable river buffer rules in 15A NCAC 2B .0200, soil erosion and sedimentation control requirements in 15A NCAC Chapter 4 and under the Division's General Permit NCG010000, and any requirements pertaining to wetlands under 15A NCAC 213 .0200 and 15A NCAC 2H .0500and all applicable North Carolina Occupational Safety and Health Act health and safety standards. 4. The issuance of this permit does not prohibit the Division from reopening and modifying the permit, revoking and reissuing the permit or terminating the permit as allowed by the laws, rules, and regulations contained in 15A NCAC 2H .0200 and North Carolina General Statute §143-215.1 et. al., or as needed to address changes in federal regulations with respect to the wastewater collection system. 5. The Permittee shall pay the annual fee within thirty (30) days after being billed by the Division. Failure to pay the fee accordingly may cause the Division to initiate action to revoke this permit as specified by 15A NCAC 2H .0205(c) (4). The Permittee shall request renewal of this permit at least six months prior to the expiration of this permit. Upon receipt of the request, the Commission will review the adequacy of the wastewater collection system described therein, and if warranted, will extend the permit for a period of time and under such conditions and limitations, as the Commission may deem appropriate. 7. The Permittee shall notify the Division's Pretreatment, Emergency Response and Collection Systems Unit in writing at 1617 Mail Service Center; Raleigh, North Carolina 27699-1617 of any changes to the name and/or address of the responsible party (i.e. mayor, city/town — manager-)- of -the -wastewater -collection system_—^__ _ Any . duly authorized officer, employee, or representative of the Division may, upon presentation of credentials, enter and inspect any property, premises or place on or related to the collection system at any reasonable time for the purpose of determining compliance with this permit, may inspect or copy any records that must be maintained under the terms and conditions of this permit, and may obtain samples of wastewater, groundwater, surface water, soil, or plant tissue. Permit issued this the 14th day of April, 2005 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION � J Alan W. Klimek, P.E., Director v� Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQCS00091 PERMIT Ver.09/04 Michael F. Easley, Governor v� r William G. Ross Jr., Secretary > North Carolina Department of Environment and Natural Resources a � Alan W. Klimek, P.E., Director February 14, 2005 Richard Canipe Town Manager Town of Spruce Pine P.O. Box 189 Spruce Pine, NC 28777 WATER QUALITY SECTION Subject: Application No. WQCS00091 Additional Information Request/Draft Permit Spruce Pine Collection System Mitchell County Dear Mr. Canipe: Division correspondence of June 19, 2003 requested additional information regarding the subject application. I apologize for the length of time for this follow-up. A draft permit has been prepared for your review. Please respond to and/or address the attached information request by March 18, 2005. Please reference the subject permit application number when providing the requested information. All information should be submitted in duplicate to my attention at the address below. The information requested by this letter, must be submitted on or before March 18, 2005. If no response is received, the Division must move forward with issuing a permit. You will be expected to comply with all permit conditions on the effective issuance date. It is important that you review the draft permit thoroughly in preparation for permit issuance and to respond to the items requested in this letter. If you have any questions regarding this request, please call me at (919) 733-5083, extension 593. Sincerely, Deborah Gore Environmental Engineer Enclosures: Permit Application Comments/Request (1 page), Draft permit, Grease Ordinance examples, Response Plan examples, Collection System SSO reporting form cc: ZMike-Par_ker,zAsheville Regional Off ce; w/ Permit Application Comments/Request (I page), Draft permit Deborah Gore, WQCS00157 Permit File, w/ Permit Application Comments/Request (I page), Draft permit One Pretreatment, Emergency Response and Collection Systems Unit Internet http://h2o.enr.nc.state.us/ndpu Telephone (919) 733-5083 Fax (919) 733-0059 50% recycled/10% post -consumer paper Application No. WQCS00091 - -- Spruce Pine Collection System Attachment Page 1 February 14, 2005 Permit Application Comments/Requests Collection System Information 1. Question III, 9 of the application indicates 14 pump stations serving pressure sewers. Please verify that there are no simplex grinder pump stations at individual residences discharging to a pressure sewer system. 2. The list of pump stations provided indicated that 8 of the pump stations do not have audible alarms. Condition I, 10 of the draft permit requires pump stations that do not employ an automatic polling feature to have audible and visual alarms. Please provide a short compliance schedule (day/month/year) for when the Town will meet this requirement. Please confirm that appropriate signage has been placed at each pump station. 4. Note condition V, 4 of the draft permit regarding high priority lines. Collection System Administration 1. Our database does not list an ORC or back-up ORC. Your response from May 14, 2003 indicted that Elbert Stamey and Russell Lankford would be attending the Collection System School and taking the certification exam. Please review Part H, 1 of the Draft permit for operator requirements. Contact Steve Reid at 919-733-0026 for assistance in correcting our database. 2. The goal of this collection system permit is to create a proactive approach to preventing problems instead of a reactive approach after problems have occurred. The collection system permit conditions require that an inspection, enforcement and education program be in place and that the Town ordinance provides the authority to inspect and enforce. Attached is information regarding establishing an oil and grease program and examples of ordinances from other North Carolina municipalities. Please review this information and provide a date (day/month/year) when the Town can have an ordinance in place. Operation and Maintenance of the Collection System 1. Condition H, 8 requires at least 10% of the collection system be cleaned each year. Please confirm that this condition will be met. 2. Please review Part I, 7 for Contingency Plan requirements. Submit a copy of your plan or indicate a date (day/month/year) when a plan can be developed. 3. Please review Part II, 9 of the Draft Permit for Response Action Plan requirements. Submit a copy of your plan or indicate a date (day/month/year) when a plan can be developed. 4. A copy of the most current Collection System Sanitary Sewer Overflow reporting form is attached for your information. 5. Please review the attached draft permit and indicate if there are any conditions for which the Town currently does not comply, providing a specific date (month/day/year) of compliance. Recordkeeping requirements should be able to be implemented prior to or upon pen -nit issuance and therefore, no compliance schedules should be requested for such conditions. 6. The Division has received many questions regarding fees for this permit. Based on your current permitted flow of 2.0 MGD, an annual fee of $1090 will be charged after permit issuance. 7. Provide any other comments/corrections to the draft permit as desired. Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality June 19, 2003 Richard Canipe Town of Spruce Pine P.O. Box 189 Spruce Pine, NC 28777 Z 3 ubject: Application No. WQCS00091 Additional Information Request Spruce Pine Collection System wptER �uRE�,O�P� Mitchell County Dear Mr. Canipe: The Non -Discharge Permitting Unit has received and reviewed the information submitted on May 19, 2003. The following is a list of information still required: • Enclosed are examples of grease ordinances and education materials. Please provide a short compliance schedule for meeting the permit conditions pertaining to oil and grease. Give a specific month, day and year. • You noted that several of your pump stations do not have alternative sources of power. Although power reliability is not a permit condition, if it turns out having a generator could have prevented a spill, the Town will be held responsible for the overflow. The Division highly recommends including additional generators as part of your Capital Improvement Plan. • Please provide a dollar value (per year) for your Capital Improvement Budget. • The permit includes a 10-year built in compliance schedule for completion of maps of the collection system. At that time, pump capacity and service taps must be included on all maps. Please respond to the attached information request by July 18, 2003. If no response.is received, the Division will move forward with issuing a permit. You will be expected to comply with all permit conditions on the effective issuance date. Please reference the subject permit application number when providing the requested information. All information should be submitted in duplicate to my attention at the address below . ' If you have any questions regarding this request, please call me at (919) 733-5083, extension 551. cc: e�tille`RegionaLU�€ e,_WKfer..:Qualiq, Elbert Stanley, Town of Spruce Pine WQCS00091 Permit File Non -Discharge Permitting Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 SincereI , atalie V. Sierra, EIT Environmental Engineer Internet h1tp://h2o.enr.state.nc.us/ndpu Telephone (919) 733-5083 Fax (919) 715-6048 DENR Customer Service Center Telephone 1 800 623-7748 An Equal Opportunity Action Employer - 50010 recycled/] 00/a post -consumer paper - - W ATF 0 9 < CL' Q Michael F. Easley, Governor William G. Ross Jr., Secretary Department Environment [ North Carolina of and Natural Resources --I p -C Alan W. Klimek, P.E., Director Division of Water Quality April 14, 2003 PR 2 A4 2003 Richard Canipe Town of Spruce Pine WATER P.O. Box 189 Spruce Pine, NC 28777 ASHE 11LP ALIREITSECT0, t1 E Subject. Application No. WQCS00091 Additional Information Request Spruce Pine Collection System Mitchell County Dear Mr, Canipe: The Non -Discharge Permitting Unit has completed a preliminary review of the subject application. Attached is a summary of all the additional information required. Please respond to the attached information request by May 14, 2003. If no response is received, the Division will move forward with issuing a permit. You will be expected to comply with all permit conditions on the effective issuance date. Please reference the subject permit application number when .providing the requested information. All information should be submitted in duplicate to my attention at the address below A draft permit is also attached for your review. Note that information provided as a part of this additional information request can be used to provide compliance schedules for any permit conditions that you cannot meet upon issuance. If you have any questions regarding this request, please call me at (919) 733-5083, extension 551. Sincerel , WatalieV.rra, EIT Environmental Engineer cc: e , . c . a Elbert Stamey, Town of Spruce Pine WQCS00091 Permit File Non -Discharge Permitting Unit Internet http://h2o.enr.state.ne.us/ndpu _CD N 1 1617 Mail -Service Center, Raleigh, NC 27699-1617 Telephone (919) 733-5083 Fax (919) 715-6048 DENR Customer Service Center Telephone 1 800 623-7748 An Equal Opportunity Action Employer 50% recycled/10% post -consumer paper Application No. WQCS00091 Spruce Pine Collection System Attachment Page 1 April 14, 2003 Permit Application CommentslRequests GREASE 1) The goal of this collection system permit is to create a proactive approach to preventing problems instead of a reactive approach after problems have occurred. If there is an overflow due to grease, the Division will be trying to determine the "root cause" of the overflow. For instance, had there been grease problems from this area before? Was the problem facility inspected? Had any effort been made by the Town to correct the problem? Documentation will be key in helping the Town show.that an overflow due to grease was beyond control and that no enforcement should be taken. The collection system permit conditions require that an inspection, enforcement and education program be in place -and that the Town ordinance provides the authority to inspect and enforce. With this in mind: a) Verify items pertaining to grease and grease traps in your sewer use ordinance. If the ordinance is not descriptive enough about prohibiting grease disposal into the collection system or providing authority to inspect and enforce, .provide a compliance date for revising and approving your sewer use ordinance appropriately. Forward the revised sewer use ordinance to the Asheville regional office once developed and approved. Examples of grease and grease trap ordinances from other municipalities can be sent to you upon request. b) Your grease inspection program is not well explained in the permit application. It is the Division's position that inspections should be ongoing and not only when a new commercial establishment is constructed. There should be a set enforcement procedure as well. If necessary, provide compliance dates as to when a regular inspection and enforcement program will be developed and implemented. c) An educational program must be in place for both residential and commercial customers. This can be as simple as a flyer or bill stuffer explaining the proper method of grease disposal. Anytime these educational materials are used, it must be documented. A regular schedule for distributing these items should be developed. It is anticipated that such a program can be implemented within a very short time frame and should not require a compliance schedule. The Division has many examples of grease education materials that we can send upon request. REHAB/CAPACITY ISSUES 2) It was indicated that a major portion of the collection system is in the process or planning stages of rehabilitation and replacement. Provide a list of the major areas involved in the project with compliance dates for starting and ending construction work for each area, keeping in mind the time to obtain any funding, design work and permits necessary. Include as much detail as possible. 3) You did not provide the Division with the Town's response plan to Sanitary Sewer Overflows (SSOs). Please provide a description of the response plan along with how SSOs are documented. HIGH PRIORITY LINES 4) The locations of all high priority lines will be referenced in your collection system permit. Your application identified no high priority lines. The Division's definition of a high priority line according to 15A NCAC 2H .0227 is as follows: Any aerial line, sub -waterway crossing, line contacting surface waters, siphon, line positioned parallel to stream banks that are, subject to eroding in such a manner that may threaten the sewer line, or line designated as high priority in a permit. These high priority lines must be inspected every six months and documentation should be maintained when inspections occur. Determine if the Division would consider the any of your lines high priority. List the lines as necessary and provide locations. ALARMS/RELIABILITY 5) All pump stations without an advanced telemetry system will need audible and visual alarms. An autodialer alone does not meet the intent of Permit Condition I(10) regarding alarms. Indicate whether all pump Application No. WQCS00091 Spruce Pine Collection System Attachment Page 2 April 14, 2003 stations have functioning audible and visual alarms. Provide a compliance schedule for installation of such alarms if they are not in place at all pump stations. 6) There may be power reliability issues with your pump stations. It is not clear whether Spruce Pine owns portable generators for the pump stations that do not have permanent back-up generators. All generators, whether portable or permanent, should be tested under load periodically and kept full of fuel. You should also note whether all the pump stations have the capability to hook up a portable generator or if there are emergency contractors who can provide portable generators in the event of an emergency. Although power reliability is not a permit condition, if it turns out that a spill could have been prevented by having a generator, the Town will be held responsible for the overflow. The Division highly recommends evaluating power reliability issues for your pump stations. 7) Permit Condition II(5) requires one fully operational spare pump capable of pumping peak flow be maintained on hand for each pump station without pump reliability (i.e. simplex pump stations serving more than one building or pump stations not capable of pumping at a rate of 2.5 times the average daily flow rate with the largest pump out of service). Verify that all pump stations have pump reliability as defined above. If not, provide compliance dates as to when spare pumps can be on hand for these stations. Additionally, the Division recommends evaluating the feasibility of installing quick connects at main pump stations so that portable pumps can be used in the event of a problem. PUMP STATION SIGNAGE/RESTRICTED ACCESS 8) Please provide a complete list of all pump stations with the following information: • Location • Alarm type • Signage • Back-up power capabilities • Restricted access 9) Permit Condition I(8) requires signs stating the pump station name, emergency contact number and instructions to call in the event of an alarm condition. Indicate a compliance date as to when permanent and legible signs with the pump station name can be posted at all pump stations. 10) All pump stations shall have restricted access per Condition I(9) of the permit and our regulations. This means locks on control panels and wet wells if noTencing is provided or locked gates if fencing is provided.. If restricted access can not be achieved at all pump stations by June 30, 2003, please indicate a compliance schedule for securing the pump stations. BUDGET 11) Permit Condition I(5) requires a Capital Improvement Plan (CIP) that shows a minimum of 3-5 years worth of planning and reinvestment towards the collection system. Provide a brief description of your CIP with regard to the collection system. If a CIP meeting this condition is not available, provide a compliance schedule for developing the CIP. The Division recommends specific line items for the collection system as opposed to combining water, sewer and WWTP funds together under common line items (which is what Spruce Pine appears to have done). Guidance for creating a CIP is available upon request. 12) Verify whether the $151,200 listed as the operation and maintenance budget is solely for maintenance of the collection system. Please also provide a basis for this number. RECORD KEEPING 13) Please review the operation and maintenance requirements of the permit. We will assume that the plans, record logs and inspections required will be in place by permit issuance. If not, identify the outstanding items and provide compliance dates for meeting the permit condition. 2 Application No. WQCS00091 -- Spruce Pine Collection System Attachment Page 3 April 14, 2003 MISCELLANEOUS 14) Ensure that no overflow piping exists from manholes and pump stations to water features. Any existing overflow piping should be removed or permanently capped. A very short compliance schedule may be allowed to remove or cap these lines, if necessary. 15) Please note whether your ORC, Elbert Stamey, has been certified. Under the conditions of the permit, a back-up ORC must also be designated for the collection system. Provide the name of your back-up ORC. 16) Your application notes that a comprehensive map of the collection system is available. Verify that this map contains all of the following parameters: • Sewer lines: line size, pipe material and approximate age of pipes • Flow direction • Pump station identification and location • Pump type (model) and capacity • Location of all tributary collection system extension • Number of active service taps 17) It appears that Spruce Pine does not have a method of plan review and inspection for new sewer projects. Although this is not a permit condition, it is extremely important to ensure quality construction in order to avoid costly repairs or possible spills. 18) The collection system permit requires that a minimum of 10% of the lines be cleaned each year (and that supporting documentation is kept). If you require a compliance schedule to increase your current cleaning schedule to 10% per year, please provide one with your response. 19) The collection system permit also requires a general observation of the collection system each year. The intent of this condition is to observe lines that are not normally viewed by the public or are in remote areas, such as outfall lines. ADMINISTRATIVE ISSUES 20) No organizational structure for operation and maintenance of the collection system was provided in your application. Please do so. 21) Once compliance dates are submitted, the Division will review them for approval. A draft permit will be reviewed by the Non Discharge Permitting Unit, the Asheville Regional Office and the Town of Spruce Pine for final concurrence. The final permit will then be issued and renewed by the town every five years. �CF W ATFRQ �O r? r O 'C Richard Canipe Town of Spruce Pine P.O. Box 189 Spruce Pine, NC 28777 Dear Mr. Canipe: Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality YWY (issue date) Subject: DRAFT Permit No. WQCS00091 Spruce Pine Wastewater Collection System Mitchell County In accordance with your application received on May 31, 2002, we are forwarding herewith Permit No. WQCS00091, dated YYW, to Town of Spruce Pine for the operation and maintenance of the subject wastewater collection system. This permit shall be effective from the date of issuance until YYW. This comprehensive collection system permit includes conditions that cover all of the Spill Response and Operation and Maintenance Evaluation Factors in the Updated Collection System Enforcement Guidance issued June 14, 1999. Therefore, this .permit supercedes the 1999 point system used to determine enforcement options for sanitary sewer overflows. The evaluation of enforcement options after a sanitary sewer overflow will be determined considering the criteria listed in condition I(2)(a) and I(2)(b) of the permit. Compliance with all conditions of the permit must be maintained or enforcement actions may be taken in accordance with Condition VI(3). If you have questions regarding compliance contact your regional office or the Non -Discharge Compliance and Enforcement Unit of the North Carolina Division of Water Quality at (919) 733-5083. This permit shall be subject to the conditions and limitations specified herein. It is your responsibility to thoroughly review this permit. Please pay particular attention to the monitoring and reporting requirements in this permit. Failure to abide by the conditions in this permit may subject the Permittee to enforcement action. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty days following the receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made, this permit shall be final and binding. If you need additional'information concerning this matter, please contact Natalie Sierra at (919) 733-5083 extension 551. 0;!A Alan W. Klimek P.E. cc: Mitchell County Health Department Elbert Stamey, Town of Spruce Pine Asheville Regional Office, Water Quality Section Technical Assistance and Certification Unit NDPU File WQCS00091 `. Non -Discharge Permitting Unit Internet http://h2o.enr.state.nc.us/ndpu t4f-ME N 1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone (919) 733-5083 Fax (919) 715-6048 DENR Customer Service Center Telephone 1 800 623-7748 An Equal Opportunity Action Emnlover 50% recvcled/10% nnst-ennsnmer nnner TO: FROM: Forrest Westall Asheville Regional Office K. Marie Doklovic, PE I Michael F. Easley, Governor William G. Ross Jr., Secretary• North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality June 7, 2002 MEMORANDUM SUBJECT: Collection System Permit Application Spruce Pine Collection System WQC800091 JUN I I �nn2 J" The subject collection system permit application was received by the central office on May 31, 2002. Since the collection system permitting program is new, the central office would like to visit most of the systems applying for a_permit with a regional inspector. Please plan to visit the Town of Spruce Pine collection system with me within 60 days if possible. I can be contacted at 919/733-5083 x 371 to coordinate visitation schedules. We would also appreciate your review of the enclosed application. The current statutory date is August 29, 2002. The permit application enclosed can be kept for your records. A copy of the draft permit Will be forwarded for regional comment and the final permit Will be sent to you upon issuance. If you have any questions, do not hesitate to contact me. Thank you. Enclosure Cc: Permit File Non -Discharge Permitting Unit Internet httpJ1h2o.enr.state.nc.us/ndpu 1617 Mal Service Center, Raleigh, NC 27699-1617 Telephone (919) 733-5083 Fax (919) 715-6048 State of North Carolina Department of Environment and Natural Resources Division of Water Quality SYSTEM -WIDE WASTEWATER COLLECTION SYSTEMS (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) Application Number: W I (to be completed by DWQ) <THIS ONLINE APPLICATION CAN BE FILLED OUT USING THE TAB KEY TO MOVE THROUGH THE FIELDS> I. GENERAL INFORMATION: 1. System name: Town of Spruce Pine 2. Owner (name of the municipality, public utility, homeowners association, etc.): Town of Spruce Pine 3. Signing official's name and title (15A NCAC 2H .0206(b)): Richard Canipe, Town Manager 4. Name and complete address of applicant: Town of Spruce Pine P.O. Bog 189 City: Spruce Pine State: North Carolina Zip: 28777 Telephone number: (828) 765-3000 Facsimile number: (828) 765-3014 4. County where project is located: Mitchell 5. Name, affiliation, and contact information of contact person who can answer questions about the application: Richard Canipe, Town Manager P.O. Box 189, Spruce Pine, NC 28777 II. PERMIT INFORMATION: 1. Project is: ® new; ❑ modification; ❑ renewal 2. If this application is being submitted as a result of a modification or renewal of an existing permit, provide: existing permit number and the issuance date 3. Applicant is: IQ public, II private III. COLLECTION SYSTEM INFORMATION: 1. Current flow of wastewater generated by this collection system (See Instruction E): 0.30 (MGD) 2. Combined permitted flow of all treatment plants: 2.0 (MOD) 3. Explanation of how wastewater flow was determined: Influent Flow Meter 4. Owner and name of wastewater treatment facility(ies) (WWTF) receiving wastewater: Spruce Pine Wastewater Collection System 5. WWTF permit number(s): NCO021423 6. Nature of wastewater (See Instruction F): 90 % domestic/commercial; 10 % industrial; % other waste - specify: _ Basis for estimation: Domestic Water Consumption VAT FR, 1 JIAL! e SEN'_�TWI , 7. Population served by the collection system and basis for estimation (i.e. census, customers, etc.) See InstructionF:-26,133 MAY 3 1 2002 8. Total miles of sewer and (See Instruction F): 2.42 Force Main 30 Gravity li FORM- CSA OR/01* PaO'P. 1 NOW -DISCHARGE PERPf r� Pressure Vacuum map Basis for estimate 9. Number of pump stations serving the pressure * sewer: 14 * Indicate the number of simplex type pump stations serving a low pressure sewer system that are owned/maintained such as in a residental subdivision. This would not include pump stations that convey larger flows en route to the treatment plant. 10. Attach a list of all pump stations not included in Question III(8) with the following information (See Instruction G): Pump Station Name, Identification, Physical Location, Alarm Type (i.e. audible, visual, telemetry, SCADA), Restricted Access (Yes or No - If yes, what type such as locks, fencing, etc.), Pump Reliability (i.e. can pump 2.5 times average daily flow with largest pump out), Reliability Source (permanent or portable pumps), Signage Present (Yes or No - i.e. Pump station ID, emergency number, etc.). 11. List the operational units that are on hand at this time to provide power reliabiltiy and which pump stations they will serve (attach additional sheets as necessarv): Power Source (provide details as to model, capacity, etc. Portable or Permanent Pump Station(s) Served See Attached Portable Portable Portable Portable 12. List aerial lines and other high priority lines known to exist in the collection system and attach map showing location of each (See Instruction IT): IV. ADMINISTRATION OF THE COLLECTION SYSTEM: Provide a description of the organizational structure that is responsible for management, operation, and maintenance of the collection system (See Instruction 1): The chain of responsibility begins with American Water Services (contractors for the operation of the treatment plant) and the Public Works Director for the Town of Spruce Pine. Ascending responsibility lies with the Spruce Pine Town Manager and ultimately with the Spruce Pine Town Council. 2. Provide all Operator(s) in Responsible Charge (ORC), certification number and responsibility (area of control) within the collection system (attach additional sheets as necessatv): ORC Certification Number Responsibility Elbert Stamey Application Submitted Collection System Collection System Collection System Collection Sys 3. Approximate capital improvement budget for the collection system and description of the budget (See Instruction J): $ 179,910,024 4. Approximate operation and maintenance budget for the collection system and description (See Instruction J): $151,200 5. Describe the grease control program (including ordinances, inspection, education and enforcement) for the collection system. If no grease control program has been adopted, please provide a sche a for RECEIVED implementation: Grease trap requirement is part of the Sewer Use Ordinance. WATER QUALITY SECTS . 6. Describe how the grease control program and construction and inspection of private sewer confiections is coordinated with the local building inspections department: The Sewer Use Ordinance dictates gral sae � 1 2002 FORM- (..RA OR/01 PauP 2 HARGE PERN(771"!O __ . _---J i control and construction and inspections of private lines. The Town contracts with Mitchell County Inspections Dept for inspections. 7. Do you have procedures in place for implementing North Carolina General Statute 143-215.1C (public notifications of spills and annual report to customers). If not, please provide a schedule for developing these procedures: Yes, all spills are reported to the Town Manager who files a spill report with the Asheville Regional Office of the Division of Water Quality. 8. List any agreements or ordinances currently in place to address flows from satellite systems (See Instruction K)? N/A 9. Attach a list of all satellite systems having a flow or capacity greater than 200,000 GPD. Include contact information such as name, address, phone number and flow for each satellite system. Indicate N/A if no such systems are present. ® N/A V. OPERATION AND MAINTENANCE OF THE COLLECTION SYSTEM: 1. Is an accurate and complete map of the collection system available? (See Instruction L)? If not state what percentage of the system is mapped and provide a schedule for completing the map: Yes, map is available at the Spruce Pine Town Hall. 2. List the mapping parameters/descriptions included on or associated with the map such as type, pipe size, age, etc. of the collection system: 3. Has a sanitary sewer evaluation and study (SSES) been conducted on any portion of the collection system (See Instruction NI)?: No. 4. Have any parts of the collection system been modeled for hydraulics (See Instruction M)? ❑ Yes ® No Explain and provide locations of any capacity problems or sanitary sewer overflows (SSOs) indicated by the model: 5. Are sanitary sewer overflows (SSOs) documented no matter what volume? How are they documented? Yes, documented through spill reports. 6. Are operational logs maintained and reviewed periodically? ® Yes ❑ No At what frequency? Annually 7. Are maintenance logs maintained and reviewed periodically? ® Yes ❑ No At what frequency? Annually 8. Are pressure and gravity sewer systems inspected on a routine basis? ® Yes ❑ No Explain the frequency of inspections and any maintenance programs: Pumpstations are checked daily. Maintenance as needed. 9. Describe plan review and inspection procedures for new construction (if applicable): The Town seeks State approval of plans, construction inspection is done by certified engineers. 10. List all equipment available for routine cleaning of the collection system. If not owned, please indicate the source from which the equipment is available: Contracted with Mayland Septic Service, Spruce Pine, NC 11. What approximate percentage of the collection system is cleaned each year and the rationale for determining which line segments are cleaned: Percentage varies according to current need. 12. Describe the right of way maintenance program. Include whether all right of ways are currently accessible: Rights -of -way are maintained by the Spruce Pine Public Works Dept. All are currently accessible. 13. Describe any existing rehabilitation/replacement programs for the system (e.g. UI studies, pump station upgrades, pipe replacement, etc.): Replace 24" main trunk line, replace 7,000 linear feet of 15 inch line. FORM- C:.'qA OR/01 paon I 14. Describe or attach the contingency plan in place to respond to SSOs: Public Works staff is available 24 hours per day, additional response available from Mayland Septic Service. Standard NCDENR notification procedures are followed. � 1 V M AY 3 1 2002 FORM- CNA OR/01 Nun 4 1 N,3N,-DISCHARGE PEMAITT', I Applicant's Certification. - Note: 15A NCAC 2H .0206(b) requires an authorized individual to sign this application form. In the case of corporations, signature is required by a principal executive officer of at least the level of vice president, or his duly authorized representative. In the case of a municipal, state, or other public entity, a signature is required by either a principal executive officer, ranking elected official or other duly authorized employee. Duly authorized employee's must provide proof from the principal executive o ficer or ranking elected offlical that they have been authorized to sign this application. I, Richard Canine, attest that this application for System -Wide Wastewater Collection Systems has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. Note: In accordance with NC General Statutes 143- 215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: y 1�f Date: -5-j— P- 02, RECEIVED \N'ATr-7R M ALF SECTION, M AY 3 1 2002 FORM- CNA 09/01 Pnon q f NION-DISCHARGE PERWRTTWO BRAND KOHLER ONAN GENERAC GENERAC GENERAC SPECTRUM KOHLER TOWN OF SPRUCE PINE GENERATOR INFORMATION (All Units are Permanent) IV MAKE/MODEL SERIAL LOCATION PURCHAED 60ROZJ 644719 BEAVER CREEK 1999 80DGDA42092M A990849222 PRISON #1 2060260100 2065872 PRISON #2 2002 SD0060 K364-OD18EBYYY 1593010100 262063130 CARTERS RIDGE 2000 1602780100 2063261 BURLESON HILL 2000 3000S 600660 SEWER PLANT 250ROZD71 327708 WATER PLANT Town of Spruce Pine, North Carolina ,tjqe5 0001q/ Was:tew"a�e v llection system pill�Resp ons e'�Pla � (Communications, Assessment and Response Procedures) This plan is to be implemented in the event of a spill or overflow of the Wastewater Collection System. The plan is intended to allow response by key personnel within sixty (60) minutes of a reported spill. INITIAL RESPONSE Spill reported to or detected by a Collection System Operator. Wastewater Collection Operator will make preliminary assessment of the spill site within the first fifteen (15) minutes after the spill is first reported unless Maintenance Personnel are already available on site. Public Utilities Representative or Wastewater Collections Operator makes contact with key personnel from attached list within the first fifteen (15) minutes of a reported spill beginning with and continuing through the key personnel list until positive contact is made. Preliminary assessment information made available to responding personnel and instructions provided to Public Utilities Representative or Collections System Operator is required. Key Personnel reach spill site and continue assessment as required, and described in the containment and source control section of this plan. Key Personnel begin renewal action to eliminate the cause of the obstruction and/or system failure as outlined in the containment and source control diction of this plan. POST SPILL RESPONSE After containment is achieved, the Division of Water Quality must be contacted as soon as possible, but no later than twenty-four (24) hours after initial detection if - The spill has reached the surface waters; or the spill exceeds one thousand (1000) gallons. ANY SPILLS EXCEEDING 1000 GALLONS OR REACHES ANY SURFACE WATER MUST BE REPORTED WITHIN TWENTY-FOUR (24) HOURS TO DWO. Spills that are fully contained, removed quickly and are less than one thousand (1000) gallons are not required to be reported to DWQ. A spill report form should be attached to this plan and filled out and kept on file. KEY PERSONNEL CONTACT NUMBERS CONTACT / TITLE TELEPHONE Elbert Stamey Res. (828)765-2655 Public Works Director Cell (828)385-0448 Roger Carpenter Res. (828)765-8724 Public Works Supervisor Richard Canipe Res. (828)765-2351 Town Manager Cell (828)766-6915 Dave Cooley Plant (828)765-3011 Project Manager — American Water Cell (859)221-3251 Spruce Pine Wastewater Plant (828)765-3011 Spruce Pine Town Hall (828)765-3000 SOURCE CONTROL AND CONTAINMENT PROCEDURE Depending on the nature of the spill or overflow, the initial assessment should initiate the priority of source control and/or containment. If the source can be isolated through valves, plugs or other methods, the flow should be discontinued immediately or reduced to the least event possible. If pumps are not operating the electrical panels should first be inspected to determine if power has been cut off at the breaker. If so, power should be restored to the pumps. Containment methods will typically include the use of sand or dirt of some description to build dikes on both land and at any potential surface waters or the use of a backhoe to construct a containment pit to prevent spillage from reaching surface waters. In ascertaining the cause, several potential factors should be considered in the cause of pump station overflow. Is the pump station receiving external power? Are the pumps receiving power from the breaker panel? Is the pump straining to work or not responding? Is the impeller obstructed? Is the motor burnt? After the above questions have been answered, a proper response can be formulated. If the above problem is electrical and cannot be rectified with the in-house personnel, immediately initiate contact with the electrical contractor listed on the Contractors and Vendors List. Should there b an area -wide power outage, contact power company and/or emergency management from the attached Contractors and Vendors List. If the problem is mechanical in nature, collect parts from maintenance shop and initiate repairs. If parts are not in inventory, immediately contact and order parts to be delivered as soon as possible from vendors listed on the Contractors and Vendors List. In the event of a sewer blockage causing a manhole overflow, immediately jet out line, removing blockage with sewer jetting machine. CONTACT LIST FOR CONTRACTORS AND VENDORS Plumbing, Trenching and Digging Phillips Grading (828)765-9296 Sewer Pump Trucks Mayland Septic Company (828)765-9715 (828)765-1183 (cell) Electrical Contractor Winchester Electric (828)766-7416 McKinney Electric (828)765-7910 Electrical Company Progress Energy (800)419-6356 French Broad Electric (800)222-6190 Parts/Equipment RESPONSE EQUIPMENT Backhoe Pressure Washer Sewer Pipe & Fittings Safety Equipment Portable Pump Portable Generator & Lights SUPPLIES Lime, Straw, Chlorine, Rubber Gloves, Boots, Goggles, Mask • Ll OUTFALL Put up warning tape "DANGER — DO NOT ENTER" around S.S.O. site. In an open are, lime (powder) heavily and till. Repeat the procedure to ensure contact of all affected areas. Broadcast seed and straw. In the area where there is undergrowth of small trees, wash the area with doses of water. Continue with the water until no waste remains. Wait twelve (12) hours, and then lime the area heavily, being sure lime does not enter any surface waters. NOTE: Do not lime if the weather forecast is predicting rain. IN CITIZENS YARD Till the entire area if possible; apply lime and follow-up with the seed and straw. If the waste is not visible apply the lime and two (2) inches of topsoil and mix thoroughly. Apply lime lightly, broadcast seed and straw. ON ASPHALT OR CONCRETE Set up containment at/or near the storm drainage system; do not let the spill enter the storm drainage system. Put up black tape or red "DANGER — DO NOT ENTER" around the S.S.O. area. Spread lime on spillage and sand (or equivalent material) to a depth of one (1) inch. Let this stand for one (1) hour, sweep sand up. If moisture or grease is still present, repeat the procedure. After removing the contaminated material, wash down the area with high water pressure and sodium hypochlorite (bleach). Pump this back into the sewer system. Dispose of sand properly. If the spill goes into the storm drainage system, refer to any receiving water procedure. SURFACE WATERS AFFECTED BY SPILL (Stream or Creek Waters Take conductivity reading of the affected surface waters in order to determine the proper placement of the dam. The dam needs to be constructed near a manhole or at a location that is accessible to the jet/vacuum truck. Placement of the dam should be at a point where the lowest conductivity reading is measured if possible. Build hydrant water without dam failure. Station two at the dam that are capable of handling creek overflow. Use one pump for a backup. Have a backhoe at the site with extra material at all times so dam can be rebuilt if a breach occurs. Pump effluent from the dam into the manhole. 2. If rip rap is in creek, wash down with high water pressure until there is no waste residue remaining on/or within rip rap structure. 3. Put up warning tape, black or red "DANGER — DO NOT ENTER" from the S.S.O. site and at .400-foot downstream intervals until reaching the pump site. Bring the samples to the Wastewater Treatment Plant. Pull samples every twenty- four (24) hours until fecal-coliform readings less than 500 colonies are obtained. 4. If sludge enters surface waters, broom creek bottom and sides until there is no sludge residue remaining. 5. If surface waters flow into a body of water used for recreation, and/or drinking, notify the affected county and local officials as soon as the problem is discovered. TOWN OF SPRUCE PINE 106 HIGHLAND AVE. P.O. BOX 189 SPRUCE PINE NORTH CAROLINA 28777 828-765-3000 FAX 828-765-8141 ALDERMEN RICHARD CANIPE GREGG HENLINE BRENDA PITMAN TOWN MANAGER ROBERT C. WISEMAN CHIEF OF POLICE COY D. HOLLIFIELD Mike Parker NCDENR 59 Woodfin Place Asheville, NC 28801 Date: 7-29-99 Ref: -Response Time Dear Mr. Parker, As per your request I have reviewed the, spill -response plan for the Spruce Pine Wastewater Collection System. As a result of this survey it has been verified that within forty minutes of notification of a malfunction town personnel can be at any of our fifteen pump stations. This response time includes the provision of all necessary equipment to insure the continuity of operation and protection of the environment. If further documentation is necessary please contact this office at your earliest convenience. Town Manager APPROVED North Carolina Environmental Management Commission Division of Water Quality Date 19 9 , Permit # li( C) d %G 9 .� Home of Spruce Pine Mineral and Gem Festival '77 P-002 JUN 29 198 12:31 SPILL RESPONSIF, PLAN EVALUATION I _ Do you have a current 24 hour contact fist which includes phone numbers of key personnel anftr cantrador>s? X Yes —No (If Yes, please attach) 2. Do you have an equipment fist which includes what functional equipment is available and where it is locat6d? _ __ Yes Y No (If Yes, please attach) 3. Do you have the staff resources to make an on -site assessment of a spill with in two hours of notification of the spill? x Yes No (if No, please explain below) 4. Please list your standard spill response procedures: whan a SraUl report is received: t . 0ii-Call persormel are notified i=nedi ately. 2. WJ— site visited by personrie-l. _ on - call, _ evaluation. made. 3. CorrecUve action initiated: A. Necessary eq Apment, man OWpr, etO. diMELtcbed to site. B. Clean-up iutplemented as nece_-sa_rk. 4. Spill report faxed to »lit ASAP. 5. Is your spill response plan readily available to all essential personnel? �Yes No If No, please explain why: B. Are all essential personnel familiar with the spill response plan and dearly understand its contents? X Yes No If No, please explain why: I )N 2 all gUALITY SEC T I .-fl VILLE REGIONAL t !CE --"f7 P-003 JUN 29 198 12s31 'r r MAINTENANCE DEPARTMENT IMBERT STANEY IS ON CALL EVERY MONDA,Y TIMOU0f 3 HURSDA N ( D ON -CALL STARTS FRIDAY AT 3:30 Ply AND ENDS MONDAYMORNING.) HomE 1'H0m o ELBERTSTAAEY(RRA,DI4-21)-------------733-9503 --------------- BETEIML733-9563 AL. LOAMMC (RADIO - 23) ............. 765-6279............... CC3~7LL 766-5499 ROGER CARFE1`TUR (RADI D - 22)------------- 765-8724 B,RYAN CARPEATf`ER. ............. 765-8V, 4 p1�tM WOODY -------------7652127 WAYNE WARD ............765 2136 DALE 1 OOMON ...-1-828- 675A487 MONT DUNCAN --...---...68$-1946 ut �0� 6 i M Y JM 2�' y l 4 Town of Spruce Pine System Performance Annual Report .Submitted as required by the NC General Assembly House -Bill 1161 Reporting Period: January 1, 2010 to December., 1. General Information: Wat , WATER QUALITY SECTION • Name of regulated entity: " . Town of Spruce Pine Sewer Collection EZ1. and Wastewater Treatment Plant I Cn n � • Responsible person: Richard Canipemgx Responsible " 's title: Town- Manager n N www.sprucepine-nc.gov Official's location: 106 Highland Avenue, Spruce Pine 28771 Mailing address: PO Box.1+89; Spruce Pine, NC 28777. 3: Phone number: 828-765-3000 WWTP address: 909 Creed Pitman Road, northeast of Spruce Pine County:. Mitchell DWQ Regional Office: Asheville • Listing of permits: NCO021423 Wastewater Treatment Plant WQCSQ®09Seue'r Collection Sysfem WQ0002349 Land Application of Residuals • Description of sewer collection system and wastewater treatment plant: Sewer Collection Svstem-(CS): WQCS00061 Class 11 Consists of 1192 sewer connections (as,of 5-3-2011) serving a population of 2050. There are - 30 miles of gravity sewer and - 2.42 miles of force main (-171,178 ft total). There are 13 duplex pump . stations: none have SCADA,. 4.have telemetry, 10 have dual high water alarms, and 5 have diesel emergency generators on -site. The fuel vender is Tri-Co Oil Company, (Spruce Pine). The equipment service contactor is Blue Ridge Standby Power (Marion). The generators (self -tests weekly) are located at the following pump.station locations: Beaver Creek pump station - 60 KW - Kohler Burleson Hill pump station - 75 KW -.Generac Carter's Ridge pump station -100 KW -.Generac DOC Prison #1 pump station - 80 KW - Onan DOC Prison # 2 pump station - 60 KW - Generac Ten "percent (17,118 ft.) of the system is required to be cleaned annually. There were 17,550 feet cleaned in 2010. During the next year, Oak and Locust Street are scheduled for cleaning. 0 There are plans for -the construction and operation (� .12-31-2011) for an additional - 2 miles of gravity sewer, - 2 miles of force main and two new lift stations to connect the Mitchell County High School (in Ledger). This will eliminate the discharge of NPDES permit # NCO066737 which is a 0.0144 MGD WWTP consisting of: two septic tanks; dosing tank with dual alternating pumps; dual surface sand filters; 20. gpm UV disinfec ion; and effluent aeration tank. Wastewater Treatment Plant (WWTP): NCO021423 Class III 2.01MGD (phased permit 0.5 MGD & 2.0 MGD) WWTP consisting of: US Filter Rex III-(Envirex) ® mechanically cleaned bar screen (in operation since 1.998 - needs replacing); potable"water hydrant at influent (for wash down water) (needs repair or replacement); (screenings disposal - GDS pick-up 2/mo to landfill); influent pump.station with duplex 1111 gpm pumps with audible high water alarm and autodialer;' Eutek TeaCup ® headworks grit removal system; (grit disposal - GD.S pick-up every 60 days to landfill); (trickling filter - out of service); Milltronics HydroRanger ® influent ultrasonic flow meter; Hach Sigma 900 ® refrigerated composite sampler; Siemens Orval ® three concentric ring oxidation ditch with four 40 HP rotary aerators; circular clarifier (# 1- out of service) dual 55 ft dia circular clarifiers; -(#2 -- in service; #3 clarifier'- out of serice); sludge pump station with duplex 1389 gpm wet well pumps; gas chlorine feed system (uses 150 # cylinders); baffled chlorine contact basin (converted primary clarifier); Wallace and Tierman Acutec '35 sulfur dioxide gas injection dechlorination feed system (uses 150 #: cylinders); dechlorination basin; American. Sigma ® refrigerated effluent composite sampler; (anaerobic sludge digestor -- out of service); aerobic sludge digestor with dual 25 HP floating aerators (converted one old ASB, other one never converted); 1.0 meter Ashbrook Klampress ® belt filter press (- 20% solids); polymer feed system with Brennfloc CP622 ® (cationic); 3 sludge drying beds; 300. KW diesel Spectrum ,3000S emergency generator with automatic transfer switch "(Blue Ridge Standby Power); 90 degree v-notch weir; and Endress-Houser ® ultrasonic flow measuring equipment with totalizer and circular. chart recorder. n Sludge Management: WQ0002349 Land Application of Residuals. The sludge drying beds have not been used in several years, nor has the land application site been used in several ,years. Sludge is dewatered utilizing a cationic polymer and 1.0 meter Asht rook Klampress ® belt filter press. The belt press is operated 4-5 days -per week. The dried sludge is hauled by E. Luke Green Co. to the Iris Glen Landfill, located in Johnson City, TN. II. Performance Summary: Description of overall 12 month performance, noting highlights and deficiencies. By month, list of the number and type of any violations of permit conditions, environmental regulations or environmental laws, including (but not limited to): Permit Limit Violations (NOVs%and Civil Assessments) January- March 2010 - none April 2010 NOV-.2010-LV-0319 - Cadmium - daily maximum limit exceeded May - July 2010 - none August 2010 - NOV-2010" LV-0053 - Cadmium - daily maximum limit exceeded September - December 2010 - none Monitoring and Reporting Violations (NOVs-and Civil Assessments) (Illegal) Bypass of treatment facilities* January - June 2010 July 2010 NOV-2010-MV-0007 - Total residual chlorine -monitoring frequency failure (2x / wk) August — December 2010 - none Sanitary Sewer Overflows* - NOVs and Civil Assessments (*Estimated total monthly volumes and locations of events in which more than 1,000 gallons of waste reached surface waters. January -December 2010 - none Description of any known environmental impact of violations January -December 2010 -,none known Description of corrective measures taken to address violations or deficiencies - April 2010 - NOV-2010-LV-0319 - Cadmium — transcription error — amended DMR July 2010 - NOV-2010-MV-0007 - Chlorine —amended DMR adding Chlorine reading August'2010=-NOV-2010- LV-0053 - Cadmium limits were removed from the new permit based on statistical analyses & headworks analyses (quarterly monitoring) Summary: The wastewater treatment plant and sewer collection system is well operated and maintained by'the contractors and Town's staff. The overall performance indicates general compliance with permits. There was only one daily maximum permit limit violation for cadmium. There were only two data entry errors on the monthly reports, which were corrected. There are several pieces of equipment that are in need of replacement, due to age and wear. They are budgeted for replacement. III. Notification Copies of the System .Performance Annual. Report (SPAR) are available upon request at the Town of Spruce Pine's Town Hall. IV. Certification A. Certified Operators in Responsible Charge: Operator information: WWTP ORC contractor:, American Water (www.amwater.com) WWTP ORC: Darrell J.. Graham Cert. # 25819, WW-III WWTP back-up ORCs:. Phillip D. Burleson Cert. # 9907 WW-11 Russell P.-Lankford Cert. # 29246 WW-III Cert. # 985166 CS-1 Coll, Sys. ORC: Elbert E Starney III Cert. # 99061.2 CS-1 Coll..Sys. back-up ORC:. Alan. Dale Robinson- Cert. # 990618 CS-1 B. Statement by a responsible official certifying the report is accurate and complete: I, Richard Canipe, certify that this report is, accurate and complete, to the best of my knowledge. Signature of responsible official and date of report: Richard Canipe Date •�. FILE COPY NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor Mr. Richard Canipe, Town Manager Town of Spruce Pine. PO Box 189. Spruce Pine, NC 28777 Dear Mr. Canipe: Division of Water Quality Coleen H. Sullins Director SURFACE WATER PROTECTION SECTION May 12, 2011 Dee Freeman Secretary SUBJECT: Compliance Evaluation Inspection Town of Spruce Pine Wastewater Collection System 'Permit No: WQCS00001 Mitchell County Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on May 3, 2011. The facility was found to be in compliance with permit WQCS00091. Please refer to the enclosed inspection report for additional observations and comments. The collection system is a class CS -II. The ORC is a class CS-1. A grade CS -II ORC is required for the collection system. If you or your staff should have any questions, please call me at 828-296-4662. Sincerely, Wanda P. Frazier Environmental Specialist Enclosure cc: Russell Lankford, American Water, Project Manager Central Files g s. = ill - miles S:\SWP\Mitchell\Collection Systems\Spruce Pine Collection System\CEI 5-3-11.doc SURFACE WATER PROTECTION — ASHEVILLE REGIONAL OFFICE Location: 2090 U.S. Highway 70, Swannanoa, NC 28778 NorthCarohna Phone: 828-296-4600 Fax: 828-299-7043 - Customer Service: 1-877-623-6148 �atut'Q!lt,� Internet: www.ncwateruuality.ora Permit: WQCS00091 SOC: County: Mitchell Region: Asheville Compliance Inspection Report Effective: 04/14/05 Expiration:, 03/31/13 Owner! Town of Spruce Pine Effective: Expiration: Facility: Spruce Pine Collection System PO Box 189 Contact Person: Richard Canipe - Directions to Facility: System Classifications: CS2, Primary ORC: Elbert E Stamey Secondary ORC(s): On -Site Representative(s): Spruce Pine NC 28777. Title: Town Manager Phone: 828-765-3000 Certification:990612 Phone:828-765-3000 Related Permits: NCO021423 Town of Spruce Pine - Spruce Pine VWVfP Inspection Date: 05/03/2011 Entry Time: 01:30 PM Exit Time: 03`30 PM rYInspector:� Gt l7 e �17A4 /- Prima Wanda P Frazier Phone: 828-296-4500 Secondary Inspectors): Ext.4662 Reason for Inspection: Routine Inspection Type: Collection System Inspect Non Sampling Permit Inspection Type: Collection system management and operation Facility Status: ■ Compliant Q Not Compliant Question Areas: Miscellaneous Questions, .Performance Standards Operation & Maint Regmts.Records ■ Monitoring & Rpting Inspections N.Lines Regmts (See attachment summary) Page: 1 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 05/03/2011 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Inspection Summary: COLLECTION SYSTEM: WQCS00091 Class II Consists of 1192 sewer connections (as of 5-3-2011) serving a population of — 2050. There are — 30 miles of gravity sewer and — 2.42 miles of force main (-171,776 ft total). There are 13 duplex pump stations; none have SCADA, 4 have telemetry and 10 have dual high water alarms. The lift stations are inspected 7 days a week. The 5 pump stations are equipped with diesel emergency generators on -site. The generators (self -tests weekly) are located at the following pump station locations: Beaver Creek pump station - 60 KW - Kohler Burleson Hill pump station - 75 KW - Generac Carter's Ridge pump station - 100 KW - Generac DOC Prison #1 pump station - 80 KW - Onan DOC Prison # 2 pump station - 60 KW - Generac The fuel vender is Tri-Co Oil Company (Spruce Pine). The equipment service contactor is Blue Ridge Standby Power (Marion). RECENT COLLECTION SYSTEM MAINTENANCE AND INSPECTIONS: Replaced the pump at the Shannon Drive pump station. Replaced the pumps and controls at the Railroad pump station. Replaced 300 feet of 6" terracotta pipe with 6" PVC on Hillcrest Circle. Replaced 100 feet of 6" terracotta pipe with 6" PVC in the Ingles parking lot. Replaced the 2" force main and pump at the Duncan Street pump station. Installed 200 feet of 2" force main at the Spruce Pine Maintenance Building. Walked and visually inspected all manholes and creek crossing from Carter's Ridge Road pump station to McKinney Electric. Walked and checked all manholes and exposed collection system lines from the Railroad on Amethyst Street to the City Drive -In. Visually inspected most all of the sewer lines. Replaced 400 feet of 0.5" hose line on the sewer jetter. Purchased a new Root Rat nozzle. Page: 2 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: ,05/03/2011 Inspection Type: Collection System Inspect,Non Sampling Reason for Visit: Routine, Flushed the collection system line at the Feldspar Pump Station. Odor issues from the Prison lift stations have'been resolved'by the operation of a car wash next - door (upstream in the collection system). Feeding potassium permanganate is no longer necessary for odor control. ANNUAL COLLECTION SYSTEWCLEANING: There are — 30 miles of gravity sewer and — 2.42 miles of force main (-171,178 ft total). Ten percent (17,118 ft.) of the system is required to be cleaned annually. There were 17,550 feet cleaned in 2010. There have been 10,220 feet cleaned as of 4-28-2011. During the next`year, Oak and. Locust Street are scheduled for cleaning. SCHOOL PROJECT: There are plans for the construction and operation (— 12-31-2011) for an additional — 2 miles of gravity sewer, — 2 miles of force main and two new lift stations to connect the Mitchell County High School (in Ledger). This will eliminate the discharge of NPDES permit NCO066737 which is a 0.0144 MGD WWTP consisting of: two septic tanks; dosing tank with dual alternating pumps; dual surface sand filters; 20-gpm UV disinfection; and effluent aeration tank. . OPERATOR, INFORMATION: WWTP ORC contractor: American Water (www.amwater.com) WWTP ORC: Darrell J. Graham — Cert. # 25819 — WW-III WWTP back-up ORCs: Phillip D. Burleson — Cert. # 9907 — WW II Russell P. Lankford — Cert: # 29246 — WW-III and Cert. # 985166 — CS-1 Note: The contract operators also inspect the collection system and pump stations. Coll. Sys. ORC: Elbert E Stamey III — Cert. # 990612 - CS-1 Coll. Sys. Back-up ORC: Alan Dale Robinson — Cert. # 990618 — CS-1 Note: The collection system is a class CS -II. The ORC is a class CS-1. A grade CS -II ORC is required for the collection system. SYSTEM PERFORMANCE ANNUAL REPORT (SPAR): The 2610 System Performance Annual Report is in the process of being prepared and mailed to DWQ. Note: According to the Clean Water Act of 1999 (House Bill 1160), the legal requirement for submittal of the System Performance Annual Report is as follows: The owner or operator of any wastewater treatment works or wastewater. collection systems that treats or collects primarily domestic or municipal waste, must provide an Annual Report to its users or customers and to the Department of Environment and Natural Resources that summarizes the treatment work's-and collection system's, performance over a 12 month period. The System Performance Annual Report is due no later than 60 days after the end of the -reporting period. Page: 3 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 05/03/2011 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Performance Standards Yes. No NA NE Is Public Education Program for grease established and documented? ■ n n Cl What educational tools are used? Water bills contain FOG information, as well as, letters (most recent dated 4-26-11) from the Town to the restaurants. Suggestions were made to include the Town's web site on the water bills and reference the FOG program on the Town's web site. Is Sewer Use Ordinance/Legal Authority available? ■ n n n Does it appear that the Sewer Use Ordinance is enforced? ■ n ❑ n Is Grease Trap Ordinance available? ® n n n Is Septic Tank Ordinance available (as applicable, i.e. annexation) ■ n n n List enforcement actions by permittee, if any, in the last 12 months There are two approved septage haulers: Mayland Septic and Appalachian Outhouse. These haulers have allowable designated pumping times and specific manhole for dumping. Has an acceptable Capital Improvement Plan (CIP) been implemented? ■ ❑ ❑ ❑ Does CIP address short term needs and long term \"master planT concepts? ■ n n n Does CIP cover three to five year period? ■ n n n Does CIP include Goal Statement? ■ n n n Does CIP include description of project area? ■ n ❑ ❑ Does CIP include description of existing facilities? ■ n n n Does CIP include known deficiencies? ®❑ n Does CIP include forecasted future needs? ■ n n Is CIP designated only for wastewater collection and treatment? n ■ n n Approximate capital improvement budget for collection system? $38,000.00 Total annual revenue for wastewater collection and treatment? $731,318.00 CIP Comments Project Area identified in (Community Assitance grant funded) Master Plan for water and sewer infastructure. CIP addresses deficiencies, namely, I & I and pump replacements. This year — $50,000 has been spent on pump replacements. CIP is designated for: drinking water treatment, water distribution, wastewater collection and wastewater treatment. Is system free of known points of bypass? ■ n n n If no, describe type of bypass and location Is a 24-hour notification sign posted at ALL pump stations? ■ ❑ n n # Does the sign include: Instructions for notification? © n n n Page: 4 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 05/03/2011 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Pump station identifier? ■ n n n 24-hour contact numbers ■ n n n If no, list deficient pump stations # Do ALL pump stations have an "auto polling" feature/SCADA? Number of pump stations Number of pump stations that have SCADA Number of pump stations that have simple telemetry Number of pump stations that have only audible and visual alarms Number of pump stations that do not meet permit requirements # Does the permittee have a root control program? # If yes, date implemented? Describe: There is no orangeburg pipe. The Town has a new 3000 psi American Jetter, an old jetter and a new Root Rat nozzle. Comment: • . Inspections Are maintenance records for sewer lines available? Are records available that document pump station inspections? Are SCADA or telemetry equipped pump stations inspected at least once a week? Are non-SCADA/telemetry equipped pump stations inspected every day? Are records available that document citizen complaints? # Do you have a system to conduct an annual observation of entire system? # Has there been an observation of remote areas in the last year? Are records available that document inspections of high -priority lines? Has there been visual inspections of high -priority lines in last six months? Comment: Citizen complaints are logged into the computer, a work order is generated and the Town's Maintenance staff investigates and resolves. There are three high priority lines. They include Grassy Creek and the two Department of Corrections prisons. Operation & Maintenance Requirements Are all log books available? Does supervisor review all log books on a regular basis? Yes No NA NE ■nnn ■nn❑ Page: 5 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 05/03/2011 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Does the supervisor have plans to address documented short-term problem areas? ■ n n n What is the schedule for reviewing inspection, maintenance, & operations logs and problem areas? The Town contracts the inspection, operation and maintenance of the collection system and wastewater treatment plant. The contract ORC reviews daily records and logs, as well as, addresses problem areas. Are maintenance records for equipment available? ■ n n n Is a schedule maintained for testing emergency/standby equipment? ■ n ❑ n What is the schedule for testing emergency/standby equipment? weekly for 30 minutes Do pump station logs include: Inside and outside cleaning and debris removal? ■ n n n Inspecting and exercising all valves? ■ n n n Inspecting and lubricating pumps and other equipment? ■ n n n Inspecting alarms, telemetry and auxiliary equipment? ■ n n n Is there at least one spare pump for each pump station w/o pump reliability? n n ■ n Are maintenance records for right-of-ways available? ® n n n Are right-of-ways currently accessible in the event of an emergency? ■ n n n Are system cleaning records available? ■ n n n Has at least 10% of system been cleaned annually? ■ n n n What areas are scheduled for cleaning in the next 12 months? There are — 30 miles of gravity sewer and — 2.42 miles of force main (171,178 ft total). Ten percent (17,118 ft.) of the system is required to be cleaned annually. There were 17, 550 feet cleaned in 2010. There have been 10,220 feet cleaned as of 4-28-2011. During the next year, Oak and Locust Street are scheduled for cleaning. Is a Spill Response Action Plan available? n n n n Does the plan include: 24-hour contact numbers ■ n n n Response time ■ n n n Equipment list and spare parts inventory ■ n n n Access to cleaning equipment ■ n n n Access to construction crews, contractors, and/or engineers ■ n n n Source of emergency funds ■ n n n Site sanitation and cleanup materials ■ n n n Post-overflow/spill assessment ■ n n n Page: 6 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 05/03/2011 Inspection Type: Collection System Inspect Non Sampling Reason for Visit: Routine Is a Spill Response Action Plan available for all personnel? ■ ❑ ❑ Is the spare parts inventory adequate? ■ Cl ❑ Cl Comment: Records Yes No NA NE Are adequate records of all SSOs, spills and complaints available? n n ■ o Are records of SSOs that are under the reportable threshold available? ❑ 0 ■ 0 Do spill records indicate repeated overflows (2 or more in 12 months) at same location? n n ■ n If yes, is there a corrective action plan? n 0 ■ ❑ Is a map of the system available? ■ n O 0 Does the map include: Pipe sizes ■ n n Pipe materials ■ 0 n 0 Pipe location ■ n n n Flow direction ■ 0 Approximate pipe age 0 ■ ❑ 0 Number of service taps ■ n n 0 Pump stations and capacity ■ n 0 0 If no, what percent is complete? 95 List any modifications and extensions that need to be added to the map Approximate.pipe age needs to be added. Upon completion, the addition of the upcoming Mitchell County High School (tie-in) project and collection system details will need to be added. McGill prepared the map in December of 2005. There have been no SSOs this year. # Does the permittee have a copy of their permit? ■ 0 0 0 Comment: The collection system permit expires on 3-31-2013. Monitoring and Reporting Requirements Yes No NA NE Are copies of required press releases and distribution lists available? fl Cl ■ fl Are public notices and proof of publication available? n 0 ■ 0 # Is an annual report being prepared in accordance with G.S. 143-215.1C? ■ 0 n n # Is permittee compliant with all compliance schedules in the permits? Cl 0 ■ n If no, which one(s)? Comment: The 2010 System Performance Annual Report (SPAR) is in the process of being prepared and mailed to Raleigh. Page: 7 Town of Spruce Pine Sewer Line Maintenance 1) As most of our sewer lines are in the shoulder of roads, we visually inspect them while mowing streets. 2) Replaced pumps and old controls at the railroad pump station. 3) Replaced 300 feet of 6" terracotta line with 6" PVC on Hillcrest Circle. 4) Replaced pump and 2" pressure line at the Duncan Street pump station. 5) Installed new pump and 200' of 2" pressure line at Spruce Pine Maintenance Building. 6) Walked and visually checked all manholes and creek crossing from Carters Ridge Road pump station to McKinney Electric. 7) Walked and checked all manholes and exposed lines from the railroad on Amethyst Street to City Drive -In. 8) Purchased new Root Rat nozzle to help with grease and roots. 9) Replaced 400' of %" line hose on the sewer. jetter. 10) Flushed the line at Feldspar Pump station. 11) Replaced the pump at the Shannon Drive pump station. 12) Replaced 100' of 6" terracotta pipe with 6" PVC in the Ingles parking lot. I-y2e It �a ire', =Jle,. Work Order No: Requested By: 000 Address/Location: Category: Instructions: Labor Comments: Spruce Pine Public Works Department Work Order Date in: 05/03/2011 Date Required: Job Cost Allocation Equipment Materials Supervisor Signature NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary Fax to: Mr. Elbert Stamey III Public Works Director Town of Spruce Pine From: Wanda Frazier Environmental Specialist NCDENR-DWQ-SWPS Date: 4-27-2011 Re: Wastewater Treatment Plant and Collection System Inspections scheduled for May 3, 2011 @ 11 am and System Performance Annual Report (SPAR) . Here arer the documents that we discussed today. Call me anytime at 828- 296-4662. Thanks, SURFACE WATER PROTECTION SECTION —ASHEVILLE REGIONAL OFFICE Location: 2090 U.S. Highway 70, Swannanoa, North Carolina 28778 Phone: 828-296-45001 FAX: 828-299-70431 Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org An Equal Opportunity 1 Affirmative Action Employer NorthCarohna 'Aaturally o er (.t 5 2s f odor /� door 6 ex u 5�/re4,�) o ve/,db/Q7/m r — 3 � • �o- yr, rol .��� m ��(k X--�, v"I e-),> � M, M mill I Thomas Lee Ellis, P.E. Operations Manager Mayland & Hickory Piedmnt Na ura/Gas Hwy. E Sprucea Pine, NO 28777 Spruce 828.766.8786 Telephone I� 828.766.9812 Cell 828.304.8008—Hickory Telephone tom.eilis@piedmontng.com I ._ %_'/ter( `� j ,-- cat" e--y.\Y, _ 11 NyzA � 7 '"FILE COPY /f Michael F. Easley, Governor 7 William G. Ross Jr., Secretary North Carolina - partment of Environment and Natural Resources rColeen H. Sullins, Director Division of Water Quality Asheville Regional Office SURFACE -WATER PROTECTION November 14, 2-00 7 Mr.. Richard Canipe, Town Manager Town of Spruce Pine 138 Highland Avenue Spruce Pine, North Carolina,28777 Subject: Town of Spruce Pine Compliance Evaluation Inspection Permit No. WQCS00091 Wastewater Collection System Mitchell County Dear Mr. Canipe: Attached isthe report resulting from the Town of Spruce Pine's Collection ystem Permit Compliance Evaluation Inspection which I conducted on No,vember,13, 06. The ;Town of Spruce Pine is doing a good job of operating its wastewater collection -system.. Likewise-) would like to complement Seth Byrd for the good job he is doing in operating the Town's sewage pumping stations.. There are areas in which. the Town is in violation of the requirements of its collection system permit. Those are as follows: (1) Spruce Pine needs a new collection system Capital Improvements Plan. The Town's current plan is outdated and is'now a historical document. The Town's next collection system CIP should 'span a three -to five years period of time, include a Goals statement, description of service area, brief, description of the, existing collection system, discussion of known deficiencies and discussion of forecasted future needs. (2) The City's Collection System Permit requires the maintenance, -of records documenting the semi-annual inspection of the Town's one aerial crossing. (3) The City's sewer system map, while excellent, should be modified to indicate flow direction, pipe age -and pump station capacities. 2090 U.S. Highway 70, Swannanoa, N.C., 28778 828/296-4500 (Telephone) 828/299-7043(Fax) Customer Service 877-623-6748 NorTeLh olina (4) The Town needs to submit a Collection System Annual Report. Mike Buchanan with American Water could include the required collection system information in his Wastewater Treatment Annual Report. You should have a copy of this report present at time of your next collection system inspection. When looking at the two municipal pump stations serving the prisons I observed that the pump guide rails and restraining chains are badly rusted. Stainless steel would be a good replacement material. Should you need to discuss matters relating to the Town's collection system please do not hesitate to call us at 828-296-4500. Sincerely, Roy �M.Da Environmental Engineer cc: Elbert Stamey, Town of Spruce Pine Mike Buchanan, American Water PERCS Files Compliance Inspection Report Permit: WQCS00091 Effective: 04/14/05 Expiration: 03/31/10 Owner: Town of Spruce Pine SOC: Effective: Expiration: Facility: Spruce Pine, Collection System County: Mitchell PO Box-189 Region: Asheville. Spruce Pine NC 28777 Contact Person: Richard Canipe Title: Town Manager Phone: 828-765,-3000 Directions to Facility: System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s) On -Site Representative(s): Related Permits: NCO021423 Town of Spruce Pine - Spruce Pine WWTP Inspection Date: 11/13/2007 Entry Time: 09:00 AM Exit Time: 11:15 AM Primary Inspector: Roy M Davis �'r(\�}� Phone: 828-296-4500 Ext.4659 Secondary lnspector(s): Reason for Inspection: Routine Inspection Type: Compliance,Evaluation Permit Inspection Type: Collection system management and operation Facility, Status: ■ Compliant . n Not Compliant Question Areas: Miscellaneous Questions Performance Standards Operation & Maint Reqmts Records ■Monitoring & Rpting Inspections Pump Station Manhole Reqmts Lines (See attachment summary) Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/13/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: The Town of Spruce Pine is doing a good job of taking care of its sewage collection system. Seth Byrd of American Water is likewise doing a fine job of taking care of the Town's sewage pumping stations. The Town's present collection system Capital Improvements Plan (CIP) is now a historical document To meet permit requrements, the next CIP needs to span three to five years, include a goal statement (which the Town has already prepared), a description of the service area, description of existing facilities, discussion of known deficiencies, and forecasted future needs. The Town's collection system map needs to be modified to show flow direction, approximate pipe age, and pump station capacities. The Town needs to do a Collection System Annual Report. Such a report could be done in the same document as the Annual Wastewater Treatment Report being done by American Water. The Town needs to keep a record of the biannual inspection of the aerial crossing near Ingles The pump guide rails and restraining chains on the two pump stations serving the prisons are badly rusted. Stainless steel would be a good replacement material. Page: 2 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine 'Inspection Date: 11/13/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine Performance Standards Yes No NA NE Is Public Education Program for grease established and documented? ® n n Q What educational tools are used? - Is Sewer Use Ordinance/Legal Authority available? ■ fl 0 ❑ Does it appear that the Sewer Use Ordinance is enforced? ■ n n n Is Grease Trap Ordinance available? ■ n n n Is Septic Tank Ordinance available (as applicable, i.e.-annexation) ®❑ 11 List enforcement actions by permittee, if any, in the last 12 months Has an,acceptable Capital Improvement Plan (CIP) been implemented? ■ ❑ ❑ ❑ ' Does CIP address short term needs and long term \"master plan\" concepts? ■ n .n n Does CIP,cover three to five year period? ■ n n n Does CIP include'Goal Statement? M n n Does CIP include description of project area? ❑ ■ n n Does CIP include description of existing facilities? n ■ n n' Does CIP include -known deficiencies? Cl ■ ❑ ❑ - Does CIP include forecasted future needs? n ■ Ej ri Is CIP designated only for wastewater collection and treatment? n ■ n n Approximate capital improvement budget for collection system? $60,000:00 Total annual revenue for wastewater collection and treatment? $684,365.00 CIP Comments Needs improvement. Is system free of known points of bypass? ❑ ❑- n If no, describe type of bypass and location NA Is a 24-hour notification sign posted at ALL pump stations? n 'n ❑ # Does the sign.include: Instructions for'notification? ■ ❑ ❑ n Pump station identifier? ■ ❑ ❑ fl 24-hour contact numbers ■ In n n If no, list deficient pump stations None Page: 3 E Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/13/2007 Inspection Type: Compliance Evaluation Reason for visit: Routine # Do ALL pump stations have an "auto polling" feature/SCADA? n e n n Number of pump stations 13 Number of pump stations that have SCADA 0 Number of pump stations that have simple telemetry 3 Number of pump stations that have only audible and visual alarms 10 Number of pump stations that do not meet permit requirements 0 # Does the permittee have a root control program? ❑ ® ❑ # If yes, date implemented? Describe: NA Comment: NA Inspections Yes No NA NE Are maintenance records for sewer lines available? ■ n n n Are records available that document pump station inspections? ■ n n n Are SCADA or telemetry equipped' pump stations inspected at least once a week? ■ n n n Are non-SCADA/telemetry equipped pump stations inspected every day? ■ n n n Are records available that document citizen complaints? ■ n n n # Do you have a system to conduct an annual observation of entire system? ■ n n ❑ # Has there been an observation of remote areas in the last year? ■ n n n Are records available that document inspections of high -priority lines? n ■ n n Has there been visual inspections of high -priority lines in last six months? ■ n n n Comment: Needs to document inspection of high -priority lines. Operation & Maintenance Requirements Yes No NA NE Are all log books available? ■ n n Does supervisor review all log books on a regular basis? ■ n n n Does the supervisor have plans to address documented short-term problem areas? n n ■ Cl What is the schedule for reviewing inspection, maintenance, & operations logs and problem areas? As needed. Are maintenance records for equipment available? ■ n n n Is a schedule maintained for testing emergency/standby equipment? ■ n n n What is the schedule for testing emergency/standby equipment? Weekly for generators. Page: 4 Permit: WQCS00091 owner - Facility: Town'of Spruce Pine Inspection Dater 1Ill 3/2007 Inspection Type: Compliance Evaluation Reason for Visit:' Routine Do pump station logs include: Inside and'outside cleaning and debris removal? _ ■. ❑ n n Inspecting and exercising all valves? ■ .n ❑ n Inspecting and lubricating pumps and other equipment? ■ ❑ n ❑ Inspecting alarms, telemetry and auxiliary equipment? IN 0-0 Is there at least one spare pump for each pump station w/o pump reliability? ■ ri . n n Are maintenance records for right-of-ways available? ■ • n n n Are right-of-ways currently accessible in the event of an emergency? ■ n n n Are system cleaning records available? ■,. n n Has at least 10% of system been cleaned annually? n ■ n n What areas are scheduled for cleaning in the next 12 months? Town has recently purchased a trailer mounted jotter. Records indicate that approximately 5% of the system has been cleaned thus far this year. . Is a Spill Response Action Plan available? ■ n n n Does the plan include: 24-hour contact numbers ■ n ❑ Response time ■ ❑ n n Equipment list and spare parts inventory ■ n n n Access to cleaning equipment ■ n n n ' Access to construction crews, contractors, and/or engineers ■ ❑ n n Source of emergency funds n '❑ n ■ Site sanitation and cleanup materials ■ n n n Post-overflow/spill assessment ■ n n- n• Is a Spill Response Action Plan available for all personnel? ■ n ❑: n Is the spare parts inventory adequate? ❑ F1, n ■ Comment: Records Yes No NA NE Are adequate records.of all SSOs, spills and complaints available? ■ .� n n 'Are records of SSOs.that are under the reportable threshold available? I! n n n Do spill records indicate repeated overflows (2 or more in 12 months) at same location? • ❑ . n n If yes, is there a corrective action plan? ❑ ❑ n n Page: 5 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/13/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine Is a map of the system available? ■ n n n Does the map include: Pipe sizes ® n n n Pipe materials ■ .n n n Pipe location ®❑ ❑ n Flow direction n ■ ❑ ❑ Approximate pipe age ❑ ® ❑ Number of service taps ■ n n 171 Pump stations and capacity n ■ n n If no, what percent is complete? 90 List any modifications and extensions that need to be added to the map Collection system map needs to show pipe age, flow direction, and capacity of all pump stations. # Does the permittee have a copy of their permit? ®❑ ❑ Comment: NA Monitoring and Reporting Requirements Yes No NA NE Are copies of required press releases and distribution lists available? n n ■ n Are public notices and proof of publication available? n n ■ n # Is an annual report being prepared in accordance with G.S. 143-215.1 C? n ■ n n # Is permittee compliant with all compliance schedules in the permits? ■ n n ❑ If no, which one(s)? NA Comment: None #1 - Amity Park Road Pump Station Yes No NA NE Pump station type Duplex Are pump station logs available? ■ n n n Is it accessible in all weather conditions? ■ n n n # Is general housekeeping acceptable? ■ n n n Are all pumps present? ® n n n Are all pumps operable? ■ ❑ ❑ n Are wet wells free of excessive debris? o n n n Page: 6 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine. Inspection Date: 11/13/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine . Are upstream manholes free of excessive debris/signs of overflow? . ❑', ❑ ■ n Are floats/controls for pumps/alarms operable? ■ 00 Cl Is "auto polling" feature/SCADA present? n ❑ ■ n Is "auto polling" feature/SCADA operational? n n ■ n Is simple telemetry present? ■ n , ❑ T1 Is simple telemetry operational? ■ n fl n Are audio and visual alarms.present?. ■ n Cl n Are audio and visual alarms operable? ■ ❑ n n Is the Pump station inspected as required? ■ ' o n n Are backflow devices in place? ■ n ❑ ❑ Are backflow devices operable? ■ n n F1, Are air relief valves in place? n n 'n ■ Are air relief valves operable? n n n ■ # Is an emergency generator available? ■ n n n Can the emergency generator run the pumps? ■ n. n n Is the pump station equipped for quick hook-up? n Cl ■ n Is the generator operable? n n n # Is fuel. in tank and sufficient? ■ n 0 n Is the generator inspected according to their'schedule? ■ n. ■ .n Is a 24-hour notification. sign posted? ■ n n n Does it include: Instructions for notification? ■ fl n n Pump station identifier?. ,- ■ n n n Emergency phone number ■ n n n Is public access limited? ■ 00 n Is pump station free of overflow piping? ■ I=1 n fl Is the pump station free -of, signs of overflow? ■ n n n Are run times comparable for multiple pumps? 'Yes Comment: Seth Byrd with American Water is doing a fine job of taking care of this station. Page: 7 r Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/13/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine #2 - Amity Park Road Pump Station Yes No NA NE Pump station type Duplex Are pump station logs available? ■ n n n Is it accessible in all weather conditions? ■ n ❑ ❑ # Is general housekeeping acceptable? ■ n n n Are all pumps present? ® n n n Are all pumps operable? ■ n n .n Are wet wells free of excessive debris? ® n n n Are upstream manholes free of excessive debris/signs of overflow? Are floats/controls for pumps/alarms operable? Is "auto polling" feature/SCADA present? Is "auto polling" feature/SCADA operational? Is simple telemetry present? Is simple telemetry operational? Are audio and visual alarms present? Are audio and visual alarms operable? Is the Pump station inspected as required? Are backflow devices in place? Are backflow devices operable? Are air relief valves in place? Are air relief valves operable? # Is an emergency generator available? Can the emergency generator run the pumps? Is the pump station equipped for quick hook-up? Is the generator operable? # Is fuel in tank and sufficient? Is the generator inspected according to their schedule? Is a 24-hour notification sign posted? Does it include: nn■n ■nnn nn■n nn■n ■ n n n ® n n n ■ n n n ■nnn ■ n n n ■n,nn ■ n n n nnn■ n n n ■ ® n n n ■nnn nn■n ■ n n n ■nnn ■nnn ■nnn Page: 8 I Permit: WQCS00091 Owner - Facility: Town of Spruce Pirie Inspection Date: 11/13/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine Instructions for notification? ■ • n n n Pump station identifier? ■ ❑ fl f7 Emergency phone number ■ ❑ n ❑ Is public access limited?- ® n n n Is pump station free of overflow piping? ■ n ❑ fl Is the pump station free of signs of overflow? ■ n n n Are runtimes comparable for multiple pumps? Yes Comment: Seth Byrd with American Water'is doing a fine job of taking care of this station. For the record, two pump stations, serving and operated by the prisons discharge into this pump station. This station discharges into the wet well of station # 1. DEPOT - Locust Street Pump Station Yes No NA NE Pump station type Duplex Are pump station logs available? ■ n n n. Is it accessible in all-weather conditions? ■ n n n # Is general housekeeping. acceptable? ■ ❑ Q (1 Are all pumps present? - n n Are all pumps operable? ; ■ ❑ ❑ fl Are wet wells free of excessive debris? n ❑ n ■ Are upstream manholes free of excessive debris/signs of overflow? ■ n n n Are floats/controls for pumps/alarms operable? . ■ n n n Is "auto polling" feature/SCADA present? n ❑ ■ Is "auto polling" feature/SCADA operational? ❑ ❑ ■ Is simple telemetry present? ■ n n n Is simple telemetry operational? ■ n. ❑ n Are audio and visual alarms present? ■ 'o n n Are audio and visual alarms operable?, ■ Is the Pump station inspected as required? ■ n In n Are backflow devices in place? ■ ❑ fl n Are backflow devices operable? ■ n an Are air relief valves in place? n f 1 ❑ ■ Page: 9 F Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/13/2007 Inspection Type: Compliance Evaluation Are air relief valves operable? # Is an emergency generator available? Can the emergency generator run the pumps? Is the pump station equipped for quick hook-up? Is the generator operable? # Is fuel in tank and sufficient? Is the generator inspected according to their schedule? Is a 24-hour notification sign posted? Does it include: Instructions for notification? Pump station identifier? Emergency phone number Is public access limited? Is pump station free of overflow piping? Is the pump station free of signs of overflow? Are run times comparable for multiple pumps? Comment: Seth Byrd is doing a good job of taking care of the station. Reason for Visit: Routine nnn® n■nn nn®n nnn■ nn®n nn®n nn®n M 0 0 0 Page: 10 �.V i ON Is;- Compliance Inspection Report Permit: WQCS00091 Effective: 04/14/05 Expiration: 03/31/13 Owner: Town of Spruce Pine SOC: Effective: Expiration: Facility: Spruce Pine Collection System County: Mitchell PO Box 189 Region: Asheville Spruce Pine NC 28777 Contact Person: Richard Canipe Title: Town Manager Phone: 828-765-3000 Directions to Facility: System Classifications: CS2, Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: NC0021423 Town of Spruce Pine - Spruce Pine WWTP Inspection Date: 11/28/2006 Entry Time: 09:00 AM Exit Time: 01:00 PM Primary Inspector: Don Price Phone: 828-296-4500 Secondary Inspector(s): Roy M Davis Phone: 828-296-4500 Ext.4659 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Collection system management and operation Facility Status: ■ Compliant Q Not Compliant Question Areas: Miscellaneous Questions Performance Standards Operation & Maint Reqmts Records ■ Monitoring & Rpting inspections Pump Station Manhole Regmts Lines (See attachment summary) Page: 1 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/28/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: CIP needs goals statement, description of project area, description of existing facilities, known deficiencies and forecasted future needs. Town needs to establish a records keeping system tracking inspections of high -priority lines. Town's sewer system map needs to indicate flow direction, pipe age and pump stations names and capacities. Town needs to submit an Annual Collection System Report in accordance with General Statute 143-215.1 C. Page: 2 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/28/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine Performance Standards Yes No NA NE Is Public Education Program for grease established and documented? ■ n n n What educational tools are used? Mailings to commercial customers and messages on water and sewer bill. Is Sewer Use Ordinance/Legal Authority available? n n Does it appear that the Sewer Use Ordinance is enforced? ■ n n n Is Grease Trap Ordinance available? ■ .❑ fl rl Is Septic Tank Ordinance available (as applicable,. i.e. annexation) ■ n n n List enforcement actions by permittee, if any, in the last 12 months None Has an acceptable Capital Improvement Plan (CIP) been implemented? ■ Q ❑ 11 Does CIP address short term needs and long term \"master plan\" concepts? ■ n L! n Does CIP cover three to five year period? ■ ❑ fl fl Does CIP include Goal Statement? n ■ n n Does CIP include description of project area? n ■ n n Does CIP include description of existing facilities? n ■ n n Does CIP include known deficiencies? ❑ ■ n n Does CIP include forecasted future needs? n ■ n n Is CIP designated only for wastewater collection and treatment? ■ n n n Approximate capital improvement budget for collection system? $388,000.00 Total annual revenue for wastewater collection and treatment? $1,632,000.00 CIP Comments Needs modifications to meet requirements of Collection System Permit. Is system free of known points of bypass? ■ ❑ ❑ 0 If no, describe type of bypass and location Is a 24-hour notification sign posted at ALL pump stations? ■ ❑ # Does the sign include: Instructions for notification? ■ Pump station identifier? ■ 0 ❑ E! 24-hour contact numbers ■ n n n If no, list deficient pump stations None Page: 3 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/28/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine # Do ALL pump stations have an "auto polling" feature/SCADA? n ■ n n Number of pump stations 13 Number of pump stations that have SCADA 0 Number of pump stations that have simple telemetry 3 Number of pump stations that have only audible and visual alarms 10 Number of pump stations that do not meet permit requirements 0 # Does the permittee have a root control program? ❑ ❑ n ■ # If yes, date implemented? Describe: Comment: Elbert Stamey reports that all audible and visual high water alarms work. Inspections Yes No NA NE Are maintenance records for sewer lines available? ■ n Cl n Are records available that document pump station inspections? ■ n n n Are SCADA or telemetry equipped pump stations inspected at least once a week? ■ n n n Are non-SCADA/telemetry equipped pump stations inspected every day? ■ n n n Are records available that document citizen complaints? ■ n n n # Do you have a system to conduct an annual observation of entire system? ■ n n n # Has there been an observation of remote areas in the last year? ■ n n n Are records available that document inspections of high -priority lines? n ■ n ❑ Has there been visual inspections of high -priority lines in last six months? ■ n n n Comment: Town will start keeping records regarding inspection of high priority lines. Five of the Town's sewage pumping stations have permanantly installed emergency power generators. The Town does not have a portable generator capable of driving a pump station. Operation & Maintenance Requirements Yes No NA N Are all log books available? ■ n n n Does supervisor review all log books on a regular basis? ■ n n n Does the supervisor have plans to address documented short-term problem areas? ■ n n n What is the schedule for reviewing inspection, maintenance, & operations logs and problem areas? Monthly Are maintenance records for equipment available? ■ n n n Is a schedule maintained for testing emergency/standby equipment? ■ n n n Page: 4 1 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/28/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine What is the schedule for testing emergency/standby equipment? Weekly Do pump station logs include: Inside and outside cleaning and debris removal? ■ n n n Inspecting and exercising all valves? ■ n n n Inspecting and lubricating pumps and other equipment? ■ ❑ ❑ n Inspecting alarms, telemetry and auxiliary equipment? ■ n n n Is there at least one spare pump for each pump station w/o pump reliability? ■ ❑ n n Are maintenance records for right-of-ways available? 0-0 n n Are right-of-ways currently accessible in the event of an emergency? ■ n n n Are system cleaning records available? ■ Has at least 10% of system been cleaned annually? ■ n n n What areas are scheduled for cleaning in the next 12 months? No particular section. Only the Duncan Street pump station has one pump and the Town has a spare. Is a Spill Response Action Plan available? ■ n n Does the plan include: 24-hour contact numbers ■ n n Response time ■ n n n Equipment list and spare parts inventory ■ n n n Access to cleaning equipment ■ n n n Access to construction crews, contractors, and/or engineers ■ n n Source of emergency funds n n n ■ Site sanitation and cleanup materials ■ n n n Post-overflow/spill assessment n n n Is a Spill Response Action Plan available for all personnel? ■ n n n Is the spare parts inventory adequate? n n n ■ Comment: Records Yes No NA NE Are adequate records of all SSOs, spills and complaints available? ❑ ❑ n Are records of SSOs, that are under the reportable threshold available? ■ n n n Do spill records indicate repeated overflows (2 or more in 12 months) at same location? n ■ n n If yes, is there a corrective action plan? n ❑ ■ Page: 5 r <1 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/28/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine Is a map of the system available? ■ n n n Does the map include: Pipe sizes ■ n n n Pipe materials ■ n n n Pipe location ■ n n n Flow direction n ■ n n Approximate pipe age n ■ n n Number of service taps ■ n n n Pump stations and capacity n ■ n n If no, what percent is complete? 90 List any modifications and extensions that need to be added to the map Flow direction, pipe age and pump station capacities. # Does the permittee have a copy of their permit? ■ n n n Comment: . Monitoring and Reporting Requirements Yes No NA NE Are copies of required press releases and distribution lists available? ❑ n ■ ❑ Are public notices and proof of publication available? ❑ n ■ # Is an annual report being prepared in accordance with G.S. 143-215.1 C? n ■ n Cl # Is permittee compliant with all compliance schedules in the permits? ■ n n n If no, which one(s)? Comment: DOC NUMBER 1 - Pump Station Yes No NA NE Pump station type Duplex Are pump station logs available? ■ ❑ n n Is it accessible in all weather conditions? ■ n n n # Is general housekeeping acceptable? ■ n n n Are all pumps present? ■ n n n Are all pumps operable? ■ n n n Are wet wells free of excessive debris? ■ n n n Page: 6 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/28/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine Are upstream manholes free of excessive debris/signs of overflow? n n ■ 0 Are floats/controls for pumps/alarms operable? ■ n n n Is "auto polling" feature/SCADA present? ❑ ■ n Is "auto polling" feature/SCADA operational? n n ■ n Is simple telemetry present? ■ n n n Is simple telemetry operational? ■ n n n Are audio and visual alarms present? ■ n n n Are audio and visual alarms operable? ■ n n Is the Pump station inspected as required? ■ n n n Are backflow devices in place? ■ n n n Are backflow devices operable? ■ n ❑ n Are air relief valves in place? n n n ■ Are air relief valves operable? n n n ■ # Is an emergency generator available? ■ ❑ n Can the emergency generator run the pumps? ■ n n n Is the pump station equipped for quick hook-up? ❑ 0 ■ n Is the generator operable? ■ n n n # Is fuel in tank and sufficient? ■ n D n Is the generator inspected according to their schedule? ■ n n n Is a 24-hour notification sign posted? ■ n n n Does it include: Instructions for notification? ■ n n n Pump station identifier? ■ fl n n Emergency phone number ■ n n n Is public access limited? ■ n n n Is pump station free of overflow piping? ■ n n n Is the pump station free of signs of overflow? ■ ❑ n 0 Are run times comparable for multiple pumps? NE - Comment: Good looking pump station. Valve vault dry. Submersible pumps. DOC NUMBER 2 - Page: 7 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/28/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine Pump Station Yes No NA NE Pump station type Duplex Are pump station logs available? ■ n n n Is it accessible in all weather conditions? ■ n n 11 # Is general housekeeping acceptable? ■ n n n Are all pumps present? ■ n n n Are all pumps operable? ■ n n n Are wet wells free of excessive debris? ■ n n n Are upstream manholes free of excessive debris/signs of overflow? n n ■ ❑ Are floats/controls for pumps/alarms operable? ■ n n n Is "auto polling" feature/SCADA present? n ■ n n Is "auto polling" feature/SCADA operational? n n w n Is simple telemetry present? ■ n n n Is simple telemetry operational? ■ n n n Are audio and visual alarms present? ■ n n n Are audio and visual alarms operable? ■ n n In Is the Pump station inspected as required? ■ n In In Are backflow devices in place? ■ n n n Are backflow devices operable? ■ n n Are air relief valves in place? n n In ■ Are air relief valves operable? n n n ■ # Is an emergency generator available? ■ Q Q Cl Can the emergency generator run the pumps? ■ In In In Is the pump station equipped for quick hook-up? n n ■ ❑ Is the generator operable? ■ n In n # Is fuel in tank and sufficient? ■ In In n Is the generator inspected according to their schedule? ■ n In In Is a 24-hour notification sign posted? ■ n ❑ n Does it include: Instructions for notification? ■ In n n Page: 8 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 11/28/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine Pump station identifier? ■ n n n Emergency phone number ■ n n Is public access limited? ■ Q 0 0 Is pump station free of overflow piping? ■ n Is the pump station free of signs of overflow? ■ n n 0 Are run times comparable for multiple pumps? NE Comment: Good looking pump station. Valve vault dry: Force main from DOC Number 1 pump station pumps directly into wet well. Submersible pumps. 40 HP pumps. -Page: 9 - --- - tam C t c�D 10(A�,J,-�00� 1 KJL 9. S-e, I r Michael F. Easley, Governor William G: Ross Jr., -Secretary North Carolina Department, r „Wron Tent d-Natur a ou(ces z an Klimek, F'-,Ei Director D sim of Va_te Q ali �: ri Asheville Regional Office SURFACE WATER PROTECTION January 10, 2006 Mr.. Richard Canipe Town. Manager Town of Spruce Pine Post Office Box 189 Spruce Pine; North .Carolina 28777 SUBJECT: Town of Spruce Pine Compliance Evaluation Inspection Wastewater Collection, System Permit No: WQCS00091 Mitchell County Dear Mr. Canipe: Attached please find the report resulting from -the January 6, 2006 Compliance Evaluation Inspection conducted by Don Price and I. The purpose of the inspection was to evaluate the operations and maintenance of the Town's wastewater collection system and determine compliance status with. Collection System Permit WQCS00091. Don and I were well pleased with what we found. We did come to the conclusion that the Town's sewer rates are to low. An increase in sewer rates would help in providing adequate resources to support a modern collection system maintenance program. I would like for the Town to see if a place can be found in the budget for a TV camera to inspect the interior of sewer lines. Working on a sewer line without the benefit of a TV camera is largely guesswork. The Town needs to start a public education program relating to the proper disposal of residential kitchen. grease. It was agreed that a near future water/sewer bill would contain useful information. on this subject. I would encourage the use of door hangers to be placed on homes upstream from where residential grease problems are encountered in Town sewers. It was agreed that the next Capital Improvement Plan will include a goal statement. I like goal statements for the reason that the serve to remind an organization what they are about as well as the Town Council as -to why they are being asked to appropriate funds. It was agreed that over the next year that the Town would inspect all segments of the collection system not otherwise seen by the public and document same. NoO�e Carolina 2090 U.S. Highway 70, Swannanoa, NC 28778 Telephone: (828) 296-4500 Fax: (828) 299-7043 Customer Service 1 877 623-6748 Nwur,74 Town personnel ar`;6"'uo;ng an excellent job of maintaining 'equipment used. for sewer maintenance and emergency response. The Town will start documenting this activity. The Town does not currently have a formal right-of-way maintenance program. Such a program will be initiated as needed to allow access to the right-of-way during emergency response and will be documented. 10% of the system was cleaned last year but records confirming this activity were not maintained. Such a record keeping system will be initiated and maintained. The Town's draft sewer system maps are extremely well done. It would be nice if future versions of the maps included pipe age. On April 12, 2004 Permit Number WQ0023767 was issued to the Town of Spruce. Pine for the construction and operation of a sewage pumping station and force main to serve Skyline Motel. The Town should add this pump station to its list of stations to be regularly inspected and document those inspections. Attached is the form to be used to designate a Collection System ORC and a Back-up Collection System ORC. Before submitting the form you might wish to first talk to Mr.. Steve Reid with the Training and Certification Unit at 919-733-0026, Extension 314. Don and I appreciate the fine job that the Town of Spruce Pine is doing with operating its sewage collection. system. Please do not hesitate to call us at 828-296-4500 should we be able to help. you in any way. S' cerely, Roy M. Davis Environmental Engineer Enclosure cc:. Elbert Stamey, Town of Spruce Pine David Cooley, American Water PERCS Unit Asheville-Eiles_ Compliance Inspection Report Permit: WQCS00091 Effective: 04/14/05 Expiration: 03/31/13 Owner: Town of Spruce Pine SOC: Effective: Expiration: Facility: Spruce Pine Collection System County: Mitchell PO Box 189 Region: Asheville Spruce Pine NC 28777 Contact Person: Richard Canipe Title: Town Manager Phone: 828-765-3000 Directions to Facility: System Classifications: CS2, Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: NC0021423 Town of Spruce Pine - Spruce Pine VWVfP Inspection Date: 01/06/2006 Entry Time: 09:00 AM Exit Time: 02:00 PM Primary Inspector: Roy M Davis Phone: 828-296-4500 Secondary Inspector(s): Ext.4659 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Collection system management and operation Facility Status: ❑ Compliant ■ Not Compliant Question Areas: Miscellaneous Questions Performance Standards Operation & Maint Reqmts Records ■ Monitoring & Rpting Inspections Pump Station Manhole Reqmts Lines (See attachment summary) Page: 1 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 01/06/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: The Town of Spruce Pine is doing an excellent job of taking care of its collection system.The Town's monthly sewer bill is to low and needs to be increased to provide adequate resources to support a modern sewage collection system maintenance program. I would like for the Town to see if there is room in the budget for a TV camera to inspect the interior of sewer lines. Working on a sewer is guess work without a TV camera. The Town neds to start a public education program instructing its residents in the proper disposal of residential kitchen grease. It was agreed that the next water/sewer bill would contain a flyer for this purpose. It was agreed that the next Capital Improvements Plan for the collection system would include a goals statement. Such a statement would be helpful to the Town Council to more clearly understand where they are heading with the collection system. It was agreed that, over the next year, the Town would inspect all sections of the collection system not otherwise seen by the public and document same. Town personnel are doing an excellent job of maintaining equipment used for collectin system maintenance and emergency response. The Town will start documenting this activity. The Town does not currently have a formal right-of-way clearance program. Such a program will be initiated as needed and records kept. 10% of the system was cleaned last year but records supporting this cleaning were not maintained. Such records will now be kept. The Town's draft sewer system maps are extremely well done. It would be handy if the mapping could include an indication of pipe age. Page: 2 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 01/06/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine Performance Standards Yes No NA NE Is Public Education Program for grease established and documented? n ■ n n If no, provide schedule of compliance Next water bill. What educational tools are used? None at present. Is Sewer Use Ordinance/Legal Authority available? ■ n n n Does it appear that the Sewer Use Ordinance is enforced? ■ n n n Is Grease Trap Ordinance available? ■ n n n Is Septic Tank Ordinance available (as applicable, i.e. annexation) n Cl n ■ If no, provide schedule of compliance List enforcement actions by permittee, if any, in the last 12 months None. Has an acceptable Capital Improvement Plan (CIP) been implemented? ■ n n n If no, provide schedule of compliance Does CIP address short term needs and long term \"master plan\" concepts? ■ n n n Does CIP cover three to five year period? ■ ❑ n rl Does CIP include Goal Statement? n ■ n n Does CIP include description of project area? ■ n n n Does CIP include description of existing facilities? ■ ❑ n n Does CIP include known deficiencies? ■ ❑ ❑ n Does CIP include forecasted future needs? n n n ■ Is CIP designated only for wastewater collection and treatment? n n ❑ n Approximate capital improvement budget for collection system? $1,160,000.00 Total annual revenue for wastewater collection and treatment? $526,000.00 CIP Comments Is system free of known points of bypass? ■ n n n If no, describe type of bypass and location Is a 24-hour notification sign posted at ALL pump stations? ■ n n n # Does the sign include: Instructions for notification? ■ n n ❑ Pump station identifier? ■ ❑ n Cl Page: 3 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 01/06/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine 24-hour contact numbers ■ n n n If no, provide a schedule of compliance If no, list deficient pump stations # Do ALL pump stations have an "auto polling" feature/SCADA? n n n n Number of pump stations 13 Number of pump stations that have SCADA 0 Number of pump stations that have simple telemetry 3 Number of pump stations that have only audible and visual alarms 13 Number of pump stations that do not meet permit requirements 0 Provide a schedule of compliance Comment: Inspections Yes No NA NE Are maintenance records for sewer lines available? ■ n n n Are records available that document pump station inspections? ■ n n n Are SCADA or telemetry equipped pump stations inspected at least once a week? ■ n n n Are non-SCADA/telemetry equipped pump stations inspected every day? ■ Cl ❑ n Are records available that document citizen complaints? ■ n n n Are records available that document an annual observation of entire system? n ■ n n Has there been an observation of entire system in the last year? ■ n n n Are records available that document inspections of high -priority lines? In n ■ o Has there been visual inspections of high -priority lines in last six months? n n ■ n Comment: .. Operation & Maintenance Requirements Yes No NA NE Are all log books available? ■ n n n Does supervisor review all log books on a regular basis? ■ n ❑ n Does the supervisor have plans to address documented short-term problem areas? ■ n n n What is the schedule for reviewing inspection, maintenance, & operations logs and problem areas? Are maintenance records for equipment available? n ■ n n Is a schedule maintained for testing emergency/standby equipment? ■ n n n Page: 4 _f Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 01/06/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine If no, provide schedule for compliance 03/01/2006 What is the schedule for testing emergency/standby equipment? Weekly Do pump station logs include: Inside and outside cleaning and debris removal? ■ 0 ❑ 0 Inspecting and exercising all valves? ■ ❑ ❑ fl Inspecting and lubricating pumps and other equipment? ■ .❑ ❑ fl Inspecting alarms, telemetry and auxiliary equipment? ■ ❑ ❑ n If no, provide schedule for compliance Is there at least one spare pump for each pump station w/o pump reliability? ■ n ❑ n If no, provide schedule for compliance Are maintenance records for right-of-ways available? n ■ 0 n Are right-of-ways currently accessible in the event of an emergency? ■ 0 ❑ If no, provide schedule for compliance 07/01/2006 Are system cleaning records available? n ■ n n Has at least 10% of system been cleaned annually? ■ n O n If no, provide schedule for compliance 03/01/2006 What areas are scheduled for cleaning in the next 12 months? Is a Spill Response Action Plan available? ■ n Does the plan include: 24-hour contact numbers ■ ❑ ❑ 0 Response time ■ Equipment list and spare parts inventory ■ n L! n Access to cleaning equipment ■ n ❑ n Access to construction crews, contractors, and/or engineers ■ n 0 n Source of emergency funds ■ ❑ ❑ ❑, Site sanitation and cleanup materials ■ n ❑ n Post-overflow/spill assessment ■ Q n n Is a Spill Response Action Plan available for all personnel? ■ n p n Is the spare parts inventory adequate? ■ ❑ D 0 If no, provide schedule for compliance Page: 5 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 01/06/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine Comment: Records Yes No NA NE Are adequate records of all SSOs, spills and complaints available? Are records of SSOs that are under the reportable threshold available? If no, provide schedule for compliance Do spill records indicate repeated overflows (2 or more in 12 months) at same location? If yes, is there a corrective action plan? Is a map of the system available? Does the map include: Pipe sizes Pipe materials Pipe location Flow direction Approximate pipe age Number of service taps Pump stations and capacity If no, what percent is complete? List any modifications and extensions that need to be added to the map The Town showed us a draft of an excellent sewer map which presented everything we look for except pipe age. Comment: ■nnn ■nnn 100 Monitoring and Reporting Requirements Yes No NA NE Are copies of required press releases and distribution lists available? n n ■ ❑ Are public notices and proof of publication available? ❑ n ■ n Comment: . Page: 6 n r •� Ltd!%-.�-ram-,-. a a � - - Ali �9�� \_�j � 1? � _ _ � - I � \ C/ Compliance Inspection Report Permit: WQCS00091 Effective: 04/14/05 Expiration: 03/31/10 Owner: Town of Spruce Pine SOC: Effective: Expiration: Facility: Spruce Pine Collection System County: Mitchell Region: Asheville Contact Person: Richard Canipe Directions to Facility: PO Box 189 Spruce Pine NC 28777 Phone:_828-765-3000 Primary ORC: Certification: Phone: Secondary. ORC(s): On -Site Representative(s): Related Permits: NC0021423 Town of Spruce Pine - Spruce Pine WWTP Inspection Date: 01/06/2006 Entry Time: 09:00 AM Exit Time: 02:00 PM Primary Inspector: Roy M Davis Phone: 828-296-4500 Secondary Inspector(s): Ext.4659 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Collection system management and operation Facility Status: ❑ Compliant [i Not Compliant Question Areas: Miscellaneous Questions Performance Standards Operation & Maint Reqmts Records ■ Monitoring & Rpting inspections Pump Station Manhole Reqmts Lines (See attachment summary) Page: 1 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 01/06/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Page: 2 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 01/06/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine Performance Standards Yes No NA NE Is Public Education Program for grease established and documented? ❑ ❑ ❑ If no, provide schedule of compliance ,�Q--' What educational tools are used? Is Sewer Use Ordinance/Legal Authority available? I n n n Does it appear that the Sewer Use Ordinance is enforced? Is Grease Trap Ordinance available? Is Septic Tank Ordinance available? ❑ n n If no, provide schedule of compliance List enforcement actions by permitte, if any, in the last 12 months E.ZJL' Has an acceptable Capital Improvement Plan (CIP) been implemented? 'I nnn If no, provide schedule of compliance Does CIP addressshort term needs and long term \"master plant/ concepts? FFn n n Does CIP cover three to five year period? n n n Does CIP include Goal Statement? ❑ ❑ n Does CIP include description of project area? n n n Does CIP include description of existing facilities? 1_1 n n Does CIP include known deficiencies? f� n n n Does CIP include forecasted future needs? ❑` ❑ Is CIP designated only for wastewater collection and treatment? Approximate capital improvement budget for collection system? "N<,, �t j � 'f' © 06, Total annual revenue for wastewater collection and treatment? CIP Comments Is system free of known points of bypass? n n n n If no, describe type of bypass and location Is a 24-hour notification sign posted at ALL pump stations? n n n # Does the sign include: Instructions for notification? LA 5—`* fn n n Pump station identifier? AV Ao F1 F1 Page: 3 Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 01/06/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine 24-hour contact numbers 'Vrn n n If no, provide a schedule of compliance If no, list deficient pump stations Do ALL pump stations have an "auto polling" feature/SCADA? Number of pump stations l 3 nnnn Number of pump stations that have SCADA C J � (� Number of pump stations that have simple telemetry - "`� '� �� 1, Number of pump stations that have only audible and visual alarms �7 Number of pump stations that do not meet permit requirements t i _ Provide a schedule of compliance Comment: Inspections Yes No NA NE Are maintenance records for sewer lines available? 6111� 01_- � t' n n n Are records available that document.pump station inspections? n n n Are SCADA or telemetry equipped pump stations inspected at least once a week? n n n Are non-SCADA/telemetry equipped pump stations inspected every day? n n n Are records available that document citizen complaints?,� n n n Are records available that document an annual observation of entire system? � j n — n 14V Has there been an observation of entire system in the last year? n Are records available that document inspections of high -priority lines? Has there been visual inspections of high -priority lines in last 6 months? ❑ .nl� n Comment: Operation & Maintenance Requirements Yes No NA NE Are all log books available?i n n n Does supervisor review all log books on a regular basis? .n n Does the supervisor have plans'to address documented short-term problem areas? `fin n n What is the schedule for reviewing inspection, maintenance, & operations logs and problem areas? Is a schedulemaintained for testing emergency/standby ege+pment?n n n Are maintenance records fore ment available? n Page: 4 • Permit: WQCS00091 Owner - Facility: Town of Spruce Pine Inspection Date: 01/06/2006 Inspection Type: Compliance Evaluation If no, provide schedule for compliance What is the scedule for testing emergency/standby equipment? Do pump station logs include: Inside and outside cleaning and debris removal? Inspecting and exercising all valves? Inspecting and lubricating pumps and other equipment? Inspecting alarms, telemetry and auxiliary equipment? If no, provide schedule for compliance Is there at least one spare pump for each pump station w/o pump reliability? If no, provide schedule for compliance Are maintenance records for right-of-ways available? Are right-of-ways currently accessible in the event of an emergency? If no, provide schedule for compliance Are system cleaning records available? Has at least 10% of system been cleaned annually? If no, provide schedule fob compliance What areas are scheduled for cleaning in the next 12 months? Is a Spill Response Action Plan available? Does the plan include: 24-hour contact numbers Response time Equipment list and spare parts inventory Access to cleaning equipment Access to construction crews, contractors, and/or engineers Source of emergency funds Site sanitation and cleanup materials Post-overflow/spill assessment Is a Spill Response Action Plan available for all personnel? Is the spare parts inventory adequate? If no, provide schedule for compliance Reason for Visit: Routine YA- r�nnn r.�'nnn �irinn V(n n n FA'nnn �,fnn i�nnn �fnnn I nnn lnnn (nnn nnn n n n nnn nnn i nnn nnn nnn Page: 5 i l ' l Permit: WQCS00091 Owner - Facility: Town of Spruce Pine ` Inspection Date: 01/06/2006 Inspection Type: Compliance Evaluation Reason for Visit: Routine Comment: Records Yes No NA NE Are adequate records of all SSOs, spills and complaints available? n n n Are records of SSOs that are under the reportable threshold available? 6 -'9 nnn If no, provide schedule for compliance Do spill records indicate repeated overflows (2 or more in 12 months) at same location? n ❑ If yes, is there a corrective action plan? ❑ ❑ ❑ ❑ Is a map of the system available? �� n n n Does the map include: Pipe sizes ❑ ❑ ❑ Pipe materials X, n n n Pipe location X n n n Flow direction I c n n n Approximate pipe age 1-12- ❑ n Number of service taps n Pump stations and capacity ! '! 1 ! 1 If no, what percent is complete?/ C-;>-D List any modifications and extensions that need to be added to the map Comment: Monitoring and Reporting Requirements r Are copies of required press releases and distribution lists available? Are public notices and proof of publication available? Comment: n nAn n nA n Page: 6 Town of Spruce Pine Detail of Water & Sewer Revenues Budget 2005-06 2005-06 Description Acct Budget WATER & SEWER INTEREST 30-329-00 15,000 MISCELLANEOUS REVENUES 30-335-00 1,800 RURAL CTR GRANT - STUDY 30-350-01 - RURAL CTR GRANT - LINE 30-350-02 - SALES TAX REFUND 30-367-01 - AVAILABILITY FEES 30-370-00 7,400 CHARGES FOR WATER 30-371-01 796,124 CHARGES FOR SEWER 30-371-02 2ffi�1 , WATER TAPS 30-373-01 3,120 SEWER TAPS 30-373-02 `y W. PENALTIES 30-374-00 500 RECONNECT FEES 30-375-00 3,300 MISC W&S SALES 30-376-00 500 SALE OF FIXED ASSETS 30-383-00 - RETAINED EARNINGS APPROP 30-399-00 - Total Revenues 1,354,595 Town of Spruce Pine Detail of Water & Sewer Expenditures Budget 2005-06 2005-06 Description Acct Budget Non Departmental BOND PRINCIPAL PMTS 30-660-81 206,235 BOND INTEREST PMTS 30-660-82 82,710 SERVICE CHARGES 30-660-88 - DEPRECIATION EXPENSE 30-660-91 - BOND AMORTIZATION EXP 30-660-93 3,000 Department Total 291,945 Administration PROFESSIONAL SVCS ADMIN COSTS POSTAGE TRAVEL/TRAINING EQUIPMENT MAINT SUPPLIES & MATERIALS PLANT OPERATIONS CONTRACT SOFTWARE SUPPORT INSURANCE MISC Capital Department Total Water Operations TELEMETRY UTILITIES FACILITIES MAINTENANCE DISTRIBUTION SYSTEM MAINTENANCE DUES, SUBSCRIPTIONS & FEES MISCELLANEOUS INVENTORY CAPITAL CAPITAL OUTLAY ALTAPASS RD LINE CONST Department Total Sewer Operations TELEMETRY UTILITIES FACILITIES MAINTENANCE x COLLECTION SYSTEM MAINTENANCE CONTRACTED SERVICES (SLUDGE) DUES, SUBSCRIPTIONS & FEES MISCELLANEOUS INVENTORY CAPITAL ,CAPITAL OUTLAY Department Total 30-720-04 25,000 30-720-10 38,400 30-720-11 6,400 30-720-14 200 30-720-16 1,500 30-720-33 3,000 30-720-45 605,000 30-720-46 3,000 30-720-54 10,000 30-720-57 - 30-720-74 - 692,500 30-811-11 8,000 30-811-13 52,000 30-811-15 8,000 30-811-18 60,500 30-811-53 2,000 30-811-57 100 30-811-73 3,050 30-811-74 - 30-811-75 - 133,650 30-812-11 2,600 30-812-13 88,000 30-812-15 10,000 30-812-18 35,000 — 30-812-45 70,000 30-812-53 3,500 30-812-57 400 30-812-73 8,000 30-812-74 19,000 —� 236,500 Total Expenditures 1,354,595 Town of Spruce Pine, North Carolina Water & Sewer Availability & Tap Fees July 1, 2002 Rated GPM Water Service Only Sewer Service Only Meter Size Capacity Installation Availabilily Total Installation Availability Total 3/4" Inside 20 $390 $700 $1,090 $390 $900 $1,290 3/4" Outside 20 $780 $1,400 $2,180 $780 $1,800 $2,580 1" Inside 50 $500 $2,500 $3,000 $500 $3,250 $3;750 1" Outside 50 $1,000 $2,500 $3,500 $1,000 $3,250 $4,250 1.5" Inside 100 $550 $5,000 $5,550 $550 $6,500 $7,050 1.5" Outside 100 $1,100 $5,000 $6,100 $1,100 $6,500 $7,600 2" Inside 160 $600 $8,000 $8,600 $600 $10,400 $11,000 2" Outside 160 $1,200 $8,000 $9,200 $1,200 $10,400 $11,600 4" Inside 500 $2,150 $25,000 $27,150 $2,150 $32,500 $34,650 4" Outside 500 $4,300 $25,000 $29,300 $4,300 $32,500 $36,800 6" Inside 1200 $6,500 $60,000 $66,500 $6,500 $78,000 $84,500 6" Outside 1200 $13,000 $60,000 $73,000 $13,000 $78,000 $91,000 Sewer tap fees are based on the size of the water service, not sewer line size Contact the Water Department for meter sizes above 6" El Water & Sewer Service Installation Availability Total $780 $1,600 $2,380. $1,560 $3,200 $4,760 $1,000 $5,750 $6,750 $2,000 $5,750 $7,750 $1,100 $11,500 $12,600 $2,200 $11,500 $13,700 $1,200 -'$18,4.00 .$19,600 $2,400 $18,400 $20;800 $4,300 $57,500 $61,800 $8,600 $57,500 $66,100 $13,000 $138,000 $151,000 $26,000 $138,000 $164,000 Cj Proposed Rate Structure The Proposed Rate Schedule (Table 4) illustrates the base service charge for water/sewer usage, as well as the rate per thousand gallons. The following is a description of the proposed rate structure. - -- - -- - - - --- - - - - - — - - - -- -- Water & Sewer— Inside User Rates ■ For the first 2,000 gallons of usage, only a base service charge is applied. This charge would be $7.50. ■ For each additional thousand gallons, there would be an additional rate charge. The rates per thousand are illustrated in Table 4 below. Water & Sewer— Outside User Rates ■ For the first 2,000 gallons of usage, only a base service charge is applied. This charge would be $22.50. ■ For each additional thousand gallons, there would be an additional rate charge. The rates per thousand are illustrated below: i:. INSIDE USER.. RATES CONSUMPTION (GALLONS) ATER RATES SEWER RATES 0-2,000 . $7.50 $7.50 2,001 - 20,000 $1.20/1000 gallons $1.5011000 gallons 20,001-100,000 $1.40/1000 gallons $1.75/1000 gallons > 1009000 $1.60/1000 gallons $2.00/1000 gallons OUTSIDE USER RATES CONSUMPTION (GALLONS) ATER RATES SEWER RATES 0-2,000 $22.50 $22.50 2,001 - 20,000 $2.40/1000 gallons $3.00/1000 gallons 20,001-100,000 $2.80/1000 gallons $3.5011000 gallons > 100,000 $3.20/1000 gallons $4.00/1000 gallons Spruce Pine Public Works Department Work Order Work Order No: 7895 Date in: 01 /05/2006 Requested By: Vickie Waycaster Address/Location: 739 Oak Ave Category: Water Date Required: Instructions: Turn on meter #02373586 Call Mrs. Howell before you go 765-2077 Job Cost Allocation Labor Comments: Equipment Materials Supervisor Signature Spruce Pine Public Works Department - Work Order Work Order No:. . 7880 Date in: 01/03/2006 Requested, By: richard Address/Location: 415 ollis road Category: Water Date Required: Instructions: move Wanda Rose meter, locate it beside Charles Renfor's Meter # 2573179 Job Cost Allocation Labor Equipment Comments: Materials ..2 r Supervisor Signature C,,J.el* October 2005 Data Work Order,Report Town Of Spruce Pine 11W W_LS7_MTR01 1: WW_LS5_MTR01 :k . ........................................................................ 5361: 1WW_LS8 L _5710: 1 W W_LS 10_PMP02 >......, ........................................................ 1 .:'19: ` 1WT_PST03_PMP01 5 s 5718 , 1 W W_LS8_W W ELL ......................................... 5717: 1: W W_LS8_PMP02 f 5715: 1:WT_PST05_MTR02 ............ ...................... ...................... 5714 1WT_PST05_MTR01 ........................................... • s............................................................................ 5713::• 1: WT=PST_B_PS2 s N 5712: ...... 1WT_PST04_CPT :........................................ :................................! 5711 1'?. W W_LS11_PMP02 ........................................... 1:WW_LS7_PMP01 W W_LS2_W W ELL 71: ................................................. 509€ ..................... 1*WW_LS8_PMP01 .:............................. ........ 5722: 1 W W_LS1_W W ELL 5721: iWW_LS11_PMP02 r } 5720: 1<WT_PST_B_PS2 ................................ ............ ................ ... 4034: 6:WWT_LS_ENTIRE ............................................................s.... 4035: 6WWT_LS_ENTIRE 1 14-Oct-05# 14-01 14-Oct-05: 14-01 15-Oct-05'': ' 15-01 29-Aug-05: 26-01 11-Au -05'•# ....................:::................. 26-01 11 Aug 05: 26 01 ........ 11 Aug.05` 26-01 15-Aug-05' 26-01 29-Aug-05, ; 29. Aug-05 11-Aug-05:' 11: Aug-05:: ::: 8/11/2005 i; 07-Oct-05 14-0 >:merican !At this_time, Lift Station 7 Shannon Drive motor is clogged, inspect and repair problem,list all materials used to correct this SCdrrective , :problem. Record all corrective actions that were required to correct the problem on this work order.`this work order is to be r . ..... ............... .. .......... .... ... ... .............................. ............. ........ :At this time, Lift Station 8 Sullins Branch motor is clogged, inspect and repair problem,list all materials used to correct this 5 Corrective :problem. Record all corrective actions that were r uired to correct the problem on this work order. This work order is to be e9. ;........................................................................................... ............ Refence workorder 4649, it was reported that the pump was not working properly. 5 Corrective i ............................:............................................................................................................................................................ :To reflect corrective work order number 5192 which stated; Lift Station' 10 Hen redon pump 2-pipe disconnected, at this time, 5# Corrective :repair mrequ problem and record all corrective maintenance action ired on this work order as well as materials, parts and tools ....................................P........................................................_...............................................:...................................................................................................,,r :To reflect corrective work order number 4647 which stated; Lift Station 10 Henredon pump 1 basket needs replacing at this ..::Corrective :time, repair problem and record all corrective maintenance action required on this work order as well as materials, parts and .;........................................................................................................................ :To reflect corrective work order number 4648 which stated; Lift Station 8 Sullins Branch Wet Well, grease build up, clean all : 5: Corrective :aspect of this equipment at this time, repair problem and record all corrective maintenance action required on this work order as: .:.......................:........................................................ :To reflect corrective work order number 4649 which stated; Lift Station 8 Sullins Branch pump 1-not working properly, at this 5Corrective :time, repair problem and record all corrective maintenance action required on this work -order as well as materials, parts and too: ..}..............................................................................:............................:............................:....................................................:........................................................: :To reflect corrective work order number 5036 which stated; At this time North River Pump Station needs oil changed, repair 5: Corrective : problem and record all corrective maintenance action required on this'work order as well as materials, parts and tools used to .'z........................;.............................................................................................................................. :To reflect corrective work order number 5035 which stated; At this time North River Pump Station needs oil changed, repair 5:Corrective- :problem and record all corrective maintenance action'required on this work order as well -as materials, parts and tools used to To reflect corrective work order number 5033 which stated; Carter Ridge Station is not on line, repair problem and record all 5: requi Corrective icorrective maintenance action red on this work order as well as materials, parts and tools used to complete.the work. This . ....................... I. .................................. . .. .... ...... ............................. ...... ... . ..... .. ....... ...... ...... .. .......... :To reflect corrective work,order number 5034 which stated; at this time the Control Panel Telemetry board located at Cemetery: 5i Corrective :Station is out of service, repair problem and record all corrective maintenance action required on this work -order as well as ma .......................................: ........................................................................................................................................................................................ :To reflect corrective work order number 5191 which stated; Lift Station 11 Feldspars pump 2-out of service at this -time, at this 5 Corrective itime, repair problem and record all corrective maintenance action required on this work order as well as materials, parts and ......................; ............................................................................. :To reflect corrective work order number 5194 which stated; Lift Station 7 Shannon Dr. Pump 1-Clogged, at this time, repair 5:Corrective :problem and record all corrective maintenance action required on this work order as well as materials, parts and tools used to ....................... .................................................................................................................................................................................................... ........................ .......: :To reflect corrective work order number 5195 which stated; Lift Station 2 Carter Ridge Rd Wet well has'grease build up, at this : 5:Corrective itime, re .air problem -and record all corrective maintenance action required on this work order as well as materials, parts and t; P...................................................................................................._................................................................................................................ :To reflect corrective work order number 5193 which stated; Lift Station 8 Sullins Branch pump 1-Clogged, at this time, repair 1- ......... ­­­ ... "" . 5:Corrective :problem and record all corrective maintenance action required on this work order as well as materials, parts and tools used to 5: Corrective 5:Corrective :To reflect corrective work order number 4644 which stated; Lift Station 2 Carter Ridge Wet Well, grease build up, clean all 5:Corrective :aspect of this equipment at this time, repair problem and record all corrective maintenance action required on this work order as ..................................................................:............................................................................... 5: Preventative :Henerdon pump out line. Felds ar um out. ...............................................................................P.....P..... P......................................:...............:..................................................... 5: Preventative:: Work order is completed per instructions ..................................................................................................................................................................................................................................................... Page 1 C ................... ........... .......................................... ................................ ........................ ...................................................................................................................................................................................... ............. .................................................... -�9�6i &zWWT LS ENTIRE 21 -Oct-05: 2.1-�Oct-05'.-'P reventativd::: Task competed as instructions T .......... .. ...... .. . ................................ I ............................................. ............................ ............................................................................................................................ .......................................................... 7:: ifa-s- ... co, ... m'p`l'e-t'e*d- as instructed. Generate a corrective work order for Ci Management to repair r Hen redon pump put line, ty 4037:: .................... ........... Q*WW'1�-!-S-ENTIRE .............................................................................. 28-Oct-05 .......................... k-Oct-05�i P r6entative! and Feldspar R�TPJS out. j: ....................... .............. ............... ..................... .............................. .................................................. .............................................. ............... 16..'WW VEC1 03-Oct-05: Preventative::The odometer reading was collected on this vehicle. ........... .... ............................ ......... .................. ..................................... .................................................................................................................. ......... 7 .................... ......... ....... 1668: 16:W W _VEC2 13-Oct-05::�� 13-Oct-05.P reventative i 8,020 miles. �............... .......... ........... .............. ............................ .................................... .................. .................... ..................................................................................................................................... .......................................... .......................................... 4583:: .......... 18iWW VEC1 .......................................................... ....... .......................... 05-Oct-W Preventative: vehicle was clean .............. ........................................................................................................................................................................................................................................ 4138: 18-WW -YEC2 ............................. 07-Oct-05i� ...... 07-Oct-OS" Preventative:vehicle was clean ..................................................................................... .............................. .................................... .................... -` ......................... .................................................................... .. ........... ...................... ............................ I 4584:: ....................:..........I 18..'-*WW-VEC1 ................................................ ............................. 12-Oct-05!i .................................................. 1 2-Oct-051i Preventative ivehicle was cleaned ....................................... ....................................................................................................................................................................... A585: '-WW VEC1 1.& 19-Oct-053'-,,. 14-Oct-051 P reventativej cleaned vevicle ....... .......... ............ .......................... ............................. ................................................................................................................................ ................................. .............. ......................... ................. ............. ......... ............................ w. 11WW VEC2 14-Oct-05•` .. 14 -Oct--05�` Preventative ivehicle was cleaned ........... ........... .... ... ........... ........... 4140: ..................... ........... 18wWW -VEC2, ................................................ ............................. 21 Oct 21-Oct-05-* 'Preventative: Work Order completed as per instructions ........................................................ 4586: 18:WWeventati 21-Oct-05". 21 Oct-Oct-05-'P ive ETask competed as per instructions -YEC1 ............ ....... ...................................... ............................ .......................... ............. ...... .......................................................................................... ......................................................................................................................................... 4141 ........... 1WW 18, -VEC2 ...... ........ ............... .......................................................... 28-Oct-05: X 28-Oct-05.`. Preventative: as completed as instructed. ............................................... ... .................................................................................................................................. i: .......... ........... .................... ............ 4587: .................... I .......... 18.' W W VEC1 ........ ....................................... ............................ 28 -Oct-05:: .................................................. 28-Oct-05..,.. Preventative: Task was completed as instructed. ............................................... .............................. ................................ ............................... 5574i .................... ................................ 21'WW'-VEC ........................................................ -Oct-05:'.*. 03 .. : .......................... % 03-Oct-05 Preventative: Mountain Chevrolet winterized the vehilces; .. ........... ............................... ......................................................................................................................................................................................................... i 5563:: ................... �I'WW-YECI . ...................................................... . 03-Oct-05�� ......................... .......................... 03-Oct-05',PreventativeMounta7in Chevrolet winterized the vehilces ......... .............. ..................................................................................................................................................................................................................................... NWT--LS-ENTIRE 09-Oct-o&� 09-Oct-05 Preventative:: ......................... i ....................... 11 ............................. .......................... j: ..................................... ! .......... 1 ............................................................................................................................ ............ ........................................................... NT SAFETY 05 -9� ................................................................................................ 14 Oct 05 14-Oct-05,. Preventative :Com leted as instructed. , I ......................... .......... ..... ........................... ....................... ........ 11) ......................................................................................................................... NT EXTINGU!S�EM2# -- 24-Oct-0 ntative::This work order was completed as instructed. .................. ............................ ... ...... ! ........ . .......................... I ..................................................... .................................. : ........ I ......................... ............................................... ............................................. ...... .... .... 5452:: ..................... 6&WT EXTINGUISHER 01 ....... �.w ................................................................... 24-Oct-05............................................ Preventative :This work order was completed as instructed. ................................................. ...................................................... ............................................................................................................................. 5476: ................ .................... 68,WT-EXTINGUISHER 03� ................... - ............. ...... ............................. 24-Oct-05:.. .............................. P�!�YT�ive;: Completed work order -as instructed. ...... ....................... ........................................................... ........................................................... ................................................. .......................... 4253 ....................... 80'..-'*WWT'LS ENTIRE ........... ............................... 01-Oct-05: ....... * .............. .......................... 01-Oct-05,., 'Preventative LS entrie is completed, nothing to nR� ............. ....................... ............................................................. ............................................................ 4254: ................ ...... 80fflWT�-!-S-ENTIRE ............ ..................................... ................................ 02-Oct-05: . ...... 02-Oct-o�� Preventative LS entrie is completed, nothing to report .. .................... .. ........................................ ................................................................... 4255 .............. .......... 80."WWT ENTIRE ............. . ...................... : ............................. 03-Oct-05�: .......................... 03-Oct-05� Preventative: LS entrie is completed, nothing to report ....................... .................................................................................................................................................................................................................................... 80e<WWT LS ENT E -Oct-05'.' -Oct-05.� IR 04 04 Preventative:: LS entrie is completed, nothing to report ............ ...................... I ................................................................. ........................... ...................... . ................................................................. ............................................................................................................................................................... 'Page 2 WWT�-!-S—ENTIRE ....... I ............................ : ..... WWT—LS—ENTIRE ....................................... WWT LS ENTIRE 4263: ................ ...... N1.WWT.-.!-S-. 4264::. ..................................... 80.'.WWT ILS ...... 4265: ..... ........... 80'. WWT LS. �266:: .................... W WT LS M - 4271 ....................... 4272' 4273: ...................... 4274: .................... -1?75::: 4276:: ................... ,4277:: ................... 4278,:: 4279:: .................... 4280: . .......... 4281 ................... ............... e ....... .05.-.O.ct.-.05i:� ........ 05- . 0 . ct-( 06-0ct-05.1 06-0ct-( 08-Oct-05iii 08-Oct-( .................. K ...................... 09-Oct-( .................. v ..... E. 10-Oct-05 ............... ............................ .................. 10-0( 11 -Oct-O&�i .............. .................. 11-0( E........12-0ct-05�i� ... .... ............................ .................. 12-0( . E 13-Oct-05!i! ..................... .................. 13-0( 14-O05i,?'.. .. ct- ....................... 14-0( ....... E 115-Oct-051: ..................................................... 15-0( E 16-Oct-05:::. ............... ........................ * .... ................... 16-0( E 17-Oct-05 ........................ . .1 . ............... 18-'Oct-05:: .................. 18-0( ........... E 19-Oct-051�i ............... ............................. .................. 19-0( X E X .............. ................... 20-0( I ...................................... ).WWT—LS—ENTIRE ....................................... MWT LS ENTIRE I ................................. )'WWT—LS—ENTIRE ................................ .)'WWT—LS—ENTIRE )' WWT—LS—ENTIRE ............ )iWWT LS ENTIRE ..................................... 21 -Oct-0&ii 21 ................................ .. . .......... ... .............. .. . .. . . . .... .................................. ......... ....................... ............... . . ............... . ........................ . .. ....... ................. ...... I .. Preventative: ...................... .................. Preventative:: Henerdon..pump outline. Feld pump out.- ................................................ : .......................... I ...... ............ ...... ................. ....... .......... ....... ...... ....... ...................... Preventative: Henredon pump out line. Feldspar p .............. ......................................................................................................................... ; ........................................................... P.reve.p.t.ativ.e:H.�n.r.ed.on.pyTRp��!in!�..,F!�ld Feldspar ump.py!: .................................................................................................................................................. Preventative' Eguipment inspected, workorders written ...... ............................................................................ ......................................................... .............................................. Preventative! Eqyip inspected,corrective workorders written ...................... ............................................ ! ................................................................................................................................................................ Preventative:P Eguipment inspected, corrective workorders written ................. ........................... ................................................................................................................................... .................................................................... c Preventative:: Eguipment inspected, corrective workorders written ......................4 . .......................................................................................................................................................................................................................... Preventative::E uipment inspected, corrective workorders written ...................... ............................................................................................................................... ..................................................... ! ........................................ Preventative:.E.g.uip.m.en.t.in.s.p.ected.,..c.br.rective.workorders written ..................................... ........................ . .. . ..... .. ... . ... . . ......... . ... ........... .. * ......... .............. ........... - .................. *'****"* ............ Preventative:: This work order is competed as per instruction . ... ..................................................................................................................................................................................................................................................... Preventative: Eguipment inspected, corrective workorders written ................................................................................... .................................................................... ................................................. ................ ...................... . ........ Preventative:: Eguipment inspected, corrective. workorders written ...................... ........................................................................................................................ ............................................................................................ Preveritative! This work order is competed as per instruction ........................ .......................................................... I ..................................................................................................................................................... I ................. Preventative: Task competed as per instructions ...................... ........................................................ : ..... ........... .................................. Preventative iTask competed as per instructions ..... .......................................................................... ; ........................................................................................................................................................ - :This -work order was completed as.instructed. Request a generated corrective work order to notify City Management r G'i�6 Preventative:: repairs of Henredon pump out line and Feldspar pump ....................... ..................................................................... ..................... ..................................................................... i ................................................. . Preventativepleted work order per task instructions. . ..... ..... I ..... T .......................................... I ................................................................................................................................................................. ::Task was completed as instructed. Generate a corrective work order for C4 Management to repair Henredon out iine,",, pump Preventative:: and Feldspar pump is out. ............................................................................................................................................................................................................................................................ ::Task was completed as instructed. Generate a corrective work order for City Management to repair Henredon pump out line, Preventative i and Feldspar mp��.qq!%.' : ............................................................................. .............. R� ...................... . ........................ ... ................................................................. Task Was completed as instructed. Generate a corrective work order for City Management to repair Henredon pump out line, Preventativeiand Feldspar is out ...... ................................ ....... ::Task was completed as instructed. Generate a corrective work order for City Management to repair Henredon pump out line, Preventative:: and Feldspar pump is out. .............................................. ............................ S ............................... ................................................................................................................................... :Task was completed as instructed. Generate a corrective work order for City Management to repair Henredon pump out line, Preventative:: and Feldspar pump is -out. ....................... : ................................................................................................................................................................................................................................... ::Task was completed as instructed. Generate a corrective work order forCity Management to repair Henredon pump out line, Preventative:: and Feldspar pump is out. ...................... ....................... .......................................................... .......................................... . ..................... ................................................ ......................... Page 3 .................... ............................................................ ............................ .................................................................................................................. : ....................................................... I .......................................................... I .............................. corrective-line, :Task was completed as instructed. Generate a corrective work order for City Management to repair Henredon pump out 4282: ................................ ' 80,,WWTLSENTIRE L— ................................................ ............................ 30-Oct-05:: ........................... 30-Oct-05.1- Preventative: and Feldspar pump is out. ....................... .................................. ............................................................................................................................................... . ............................................. 91'W.WT_LS,_Motor 03-Oct-05 03-Oct-05,Preventatve:Inspected, found to be OK' . ....5516 ............. .....I............................................. ..m...................................................................................................................................... ........................... . ................................................. 5059 .......... 971WT �Safety_TG ....... .................................................................... 28-Sep-05i. 07-Oct-05�'. Preventative :PleasePress the fire Extinguisher. .................... I .................................................................................................................................................................................................................................................................. :The topic of the meeting .was on "How not to use gasoline," which is attached to this workorder. The following attend;RFRIS", 5418: 9 12- ct-05::" 9 I' 12-Oct-05�*: Preventative! meeting; Dave Cooley, Seth Byrd, Phillip Burleson, Darrell Graham. ........... . ........... ........................................ .......................................................................................................................... ............................ ..................................................... ;This -safety tail gate meeting was held by Dave Cooley on the Safety Training Topic "Your Friend the Fire Extinguisher. 1 97 WT--,Safe 21 -Oct-05: 22-Oct-05'Preventafive Attendance -included the following; Dave Cooley, Anthony Holder, Mike Buchancan. .......... ................. ................... ............................ ........................... ............................................................................ V ........................................................................................................................................................................ ':This safety tail gate meeting was held •by Dave Cooley on the Safety Training Topic "Handling Materials". .............. _TG ................... ...... 27-Oct-05 .............. 26-Oct-05 Preventative::Attendance included the following; Dave Co ley, Darrell Graham Seth Byrd, PhillipB6rleson. .................. .... ... ................................... ............. ............................................... ............. ................... ...................................................................... 5060 97WT—Safe 14-Oct05:" 27-Oct-05.,..P Preventative Work order has not been retu returned atthistime. .............................................. ............................... ...... .... ........................ ...............................................''-'-... '_'..........--..i--....-..--ii.....---------.-- .....---------- -- ...... ......-- bave �60��6elda Safety Tailgate Meeting on"Compressed Aii Safely Follow up." The following.employees attended this 5062 97.-vaf jG ct05. 27-Oct -05�Preventativeimeefing, Dave C Michael G(indstaff. .......... ....................... .......... ................................................I.......................................................................................................................... j241: 120'WT PSr�_CVAL 21-Oct-05 21-Oct -05PreventativeCompleted asp instruction. .... . ............................................ ............................................................................................................... 5219: 131fflT PSTLRVAL 22-Oct-05�� ,,22-Oct-06.. Preventative:Cbmpleted per task instructions. .................... ........... ............................... ............... ............................. .......................... . ... ............. 7 ....................................................................................................................... ......................... .......... .............................. ............................................ 5230:: 132WT PS—PCVAL 22-Oct-05E§ 22-Oct-05? P r6ventative: Completed per task instructioris. ................... I ........... . ...... ............................... ....... ............................ : .......................... ....................... ............................................................................................................................................................ ..................................................................... 5153 136. Safe"2� 30-Odt-05*;', 30-Oct-05'. Preventative: This task was completed as instructed.' ........... ................................................ ............................. :; ....................................................................................................................................................................................................................................................................................... 5252: .......................... 'WWT otor 154. —M .................... ........ .............. .................................... 20-Oct-05�-` .......................... 20-Oct-05: Preventative: Completed as per task instruction. ....................... ......... ................. .............................................................................................................................................................................................. ........... ........... .... �iWT_PST­ENTIRE 03-Oct-05: .......................... ......................... 03-Oct-05�. Pieventativei LS entrie is completed, nothing to report ........................ * .................................................................................................................................................................................................. ................................. ................................................. . . �N9.i WT PST�LENTIRE 10-Oct-05:: 10-Oct-05� Preventativeithis work'order is competed as per instruction .. ..155� .... .......................................... ............................ .......................... ....................... .......................................... 1 ............... I ........................ . ............................................................................................................................................. 5310: 155, WT�_PST�_ENTIRE � ................................................ .............................. 17-Oct-05: .... 17-Oct-OS� Preventative: This work order is competed as per instruction ..................... j: ........................ * ........................... ; ....................................................................................................................................................................................................... 5311 ....................... 155iWT—PST—ENTIRE ................................................................. 24-Oct-051�i ......................... .......................... 24-Oct-05 Preventative: This work order was completed as instructed. • ....................... ........................ a ................................................ ....................................................................................................................... .................................. 3.9.2 1561 eyewash Y�Y�_ — -Oct-O&ii 01-Oct-05 Preventative sCompleted as per task instruction - .............. .................. ............... .......................... ................................................... I .............................. ................................................................................................................................................................ - 5403 1591WT� FIRSTAID �i _SAFETY�_ 17-Oct-05i� -Preventative Need to purchase anew fi taidIdt. 17-Oct-05, ..... .......... .... ............................. ........................... I ....................... .......................... .............. ................... . ................................................. . ........................................................................ ............................. 5602: 165jWT EXTINGUISHER .01 09-Oct5�� 09-Oct-05-, P reventative Completed as per Task instruction. ; ................... ........... ............................................................................... :� ......................... ........................ I .......... ............................................................................................................ .............................................................................................................. 5636 W'F_ EXTINGU - ISHER 03,., !1WW 03-Oct-05i 03-Oct-05.."' Preventative Completed as p ..................... �6.MR ............ ............................ _EXTI1 I ER_O § .......................... .!��.!!n�jtn�ruction ....................... ......................... .................................................................................................................................................................................. 5625i '2 16ffl I O-Oct-05i�� 1 O-Oct-O$ P revent4ivel Completed inspection of the fire extinguishers as instruced. .................... ........ .......... .................... ......... .... . .......................... ....................... ................................................................................... ................................................. .............................. 168.1 ........................................................... ........ -Oct-05�'Preventative itorripleted as instructed. ................ ....................... .............................................................. ................ ........................................................................................................................... ......................... Page 4 October 2005 Data Work Order Report Entire Inspections Town. Of Spruce Pine • American -Water'.., WoNum..- Task# Equipment#- .1 DueDate'l Dat - eC'om I p ete WOTYe' P Notes 4034 6 WWT—LS—ENTIRE 07-Oct-05 6-7-Oct-05 Preventative Henerdon pump out line. Feldspar pump out. 4035 6 WWT LS—ENTIRE 14-Oct-05 14,Oct-05 Preventative Work order is completed per instructions 4036 6 WVVT_LS_ENTlRE 21-Oct-05 21,-Oct-05 Preventative Task competed as per instructions Task was completed as instructed. Generate a corrective work order for City 4037 6 WWTIS_ENTIRE 28-Oct-05 30-Oct-05 Preventative Management to repair Henredon pump out line, and, Feldspar pump is out. 5164 22 WWT—LS—ENTIRE 09-oct-05 09-Oct-05 Preventative 4253 80 WWTLLS_ENTIRE 01-Oct-05 01-Oct-05 Preventative LS entrie is completed, nothing to report 4254 80 WWT.—LS—ENTIRE 02-Oct-05 02-Oct-05 Preventative LSentrieis completed, nothing to report 4255 80 WWT—LS—ENTIRE 03-Oct05 03-Oct-05 Preventative LS entrie is completed, nothing to report 4256 80 WVVT—LS—ENTIRE 04-Oct-05 04-Oct-65 Preventative LS entrie is completed, nothing to report 4257 80 WWT—LS—ENTIRE 05-Oct-05 05-Oct-05 Preventative Henerdon pump out line Feldspar pump but .4258 80 WWTLLS—ENTIRE 06-Oct-05 06,-Oct-05 Preventative Henerdon pump out line. Feld pump out. 4260 80 WVVT—LS—ENTIRE 08-Oct-05 .�08-Oct-05 Preventative Henredon pump.out line. Feldspar pump out. 4261 80 WVVT�_LS_ENTlRE 09-Oct-05 09-Oct-05 Preventative Henredon pump out line. Feldspar pump out. 4262 80 WVVt—LS—ENTIRE 1 O-Oct-05 10-Oct-05 Preventative Eguipment inspected, corrective workorders written 4263 80 WWT—LS—ENTIRE 11 -Oct-05 11 -Oct-05 Preventative Eguipment inspected, corrective workorders written 4264 80,WWT—LS—ENTIRE 12-Oct-05 12-0ct-05 Preventative Eguipment inspected, corrective workorders written. - 4265 80 W.WTLLS_ENTIRE 13-Oct-05 13-Oct-05 Preventative Eguipment inspected, corrective workorders written 4266 80 WWTLLS_ENTIRE 14-Oct-05 14-Oct-05 Preventative Eguipment inspected, corrective workorders written Page 1 4267 80 WWT_LS_ENTIRE •'15-Oct-05 15-Oct-05 Preventative . Eguipment inspected, corrective workorders written 4268 80 WWT LS_ENTIRE 16-Oct-05 16-Oct-05 Preventative This work order is competed as per instruction 4269 80 WWT_LS_ENTIRE 17-Oct-05 17-Oct-05 Preventative Eguipment inspected, corrective workorders written 4270 80 WWT_LS_ENTIRE 18-Oct-05 18-Oct-05 Preventative Eguipment inspected, corrective workorders written 4271 80 WWT_LS_ENTIRE 19-Oct-05 = 19-Oct-05 Preventative This work order is competed as per instruction 4272 80 WWT_LS_ENTIRE - 20' Oct-05 20-Oct-05 Preventative Task competed as per instructions 4273 80 WWT_LS_ENTIRE 21-Oct-05 21-Oct-05 Preventative Task competed as per instructions order to notify City Management for the repairs of Henredon pump out line and 4274 80 WWT_LS_ENTIRE 22-Oct-05 22-Oct-05 Preventative Feldspar pump out. 4275 80 WWT LS_ENTIRE 23-Oct-05 23-Oct-05 Preventative Completed work order per task instructions. Task was completed as instructed. Generate a corrective work order for City 4276 80 WWT_LS_EN.TIRE 24-Oct-05 24-Oct-05 Preventative Management to repair Henredon pump out line, and Feldspar pump is out. r Task was completed as instructed. Generate a corrective work order for City 4277 80 WWT_LS_ENTIRE 25-Oct-05 25-Oct-05 Preventative Management to repair Henredon pump out line, and Feldspar pump is out. Task was completed as instructed. Generate a corrective work order for City 4278 80 WWT LS_ENTIRE - 26-Oct-05 26-Oct-05 Preventative Management to repair Henredon pump out line, and Feldspar pump is out. Task was completed as instructed. Generate a corrective work order for City 4279 80 WWT_LS_ENTIRE 27-Oct-05 26-Oct-05 Preventative ' Management to repair Henredon-pump out line, and Feldspar pump is out. Task was completed as instructed. Generate a corrective work order for City 4280 80 WWT LS_ENTIRE 27-Oct-05 28-Oct-05 Preventative Management to repair Henredon pump out line, and Feldspar pump is out. Task was completed as instructed. Generate a corrective work order for City 4281 80 WWT LS_ENTIRE 29-Oct-05 29-Oct-05 Preventative Management to repair Henredon pump out line, avid Feldspar pump is out. Task was completed as instructed. Generate a corrective work order for City ' 4282 80 WWT_LS_ENTIRE 30-Oct-05 30-Oct-05 Preventative Management to repair Henredon pump out line, and Feldspar pump is out. -- 5308 155 WT_PST_ENTIRE 03-Oct-05 03-Oct-05 Preventative LS entrie is completed, nothing to report 5309 155 WT_PST _ENTIRE 10-Oct-05 10-Oct-05 Preventative This work order is competed as per instruction r J 5310 155 WT_PST_ENTIRE 17-Oct-05 17-Oct-05 Preventative This work order is competed as per instruction ,- 5311 155 WT_PST_ENTIRE 24-Oct-05 24-Oct-051 Preventative This work order was completed as instructed. Page 2 (--IWork Order 4181 $' Facillity: American Water yy . Date Complete: — 2% " Equipment: W WT_UIF TSTATIONS - Spruce Pine Lift Station WWT / Dept & Loc Distribution Lift Station 3 d l Q 7 Task: LFST_BLDG 5c,4 �� Date Due: 7/21/2005 Assigned To: Michael Buchan n Closing Meter. _ Misc. Cost: . WO Notes'.� r �Y N,2 )0 d' Z i h.., cL- G✓,' �� C "'! Labor: Employee Name Date Hours Parts: Qty Item# Description Required Qty .r Task Instructions. - Inspect all of these lift station, report any problem on this work order for corrective action. Equipment# Description Type Comments WW_LS1 Burleson Hill Pump Station WWT Lift Station✓ MCCv WW_LS1_MCC Burleson Hill Pump Station WWT MCC WW_LS1_MTR01 Burleson Hill Pump Station WWT Motor 01 Motor V Motaf� WW_LS1_MTR02 Burleson Hill Pump Station WWT Motor 02 WW_LS1_PMP01 Burleson Hill. Station WWT Pump 01 Pump Station WWT Pump 02 Pump 1/ Pump1^ WW_LS1_PMP02 Burleson Hill Station WWT Wet Well y1-. Cr W W_LS1 W W ELL Burleson Hill Pump WW_LS2 Carter Ridge Pump Station WWT Lift StationV MCC✓ WW_LS2_MCC Carter Ridge Pump Station WWT MCC WW_LS2_MTR01 Carter Ridge Pump Station WWT Motor 01- Motors/ WW_LS2_MTR02 Carter Ridge Pump Station WWT Motor 02 Motor WW_LS2_PMP01 Carter Ridge Pump Station WWT Pump I/ ,` (��•� [ WW LS2_WWELL Carter Ridge Pump Station WWT Wet Well WW_LS2PMP02 Carter Ridge Pump Station WWT Pump 02 Pump1F WW_LS3 Depot Pump Station WWT Lift Station r / WW_LS3_MCC Depot Pump Station WWT MCC MCCV WW_LS3_MTR01 Depot Pump Station WWT Motor 01 Motor V WW_LS3_MTR02 Depot Pump Station WWT Motor 02 Motor it WW_LS3_PMP01 Depot Pump Station WWT Pump 01 Pump Y WW_LS3_PMP02 Depot Pump Station WWT Pump 02 Pump t( WW_LS3_WWELL Depot Pump Station WWT WET WELL WET WELD✓ WW_LS4 Prison Pump Station 1 WWT Lift Station GIIW_LS4_MCC Prison Pump Station 1 WWT MCC MCC WW_LS4_MTR01 Prison Pump Station 1 WWT Motor 01' Motor,, WW_LS4_PMP01 Prison Pump Station 1WWT Pump 01 Pump/ WW_LS4_PMP02 Prison Pump Station 1 WWT Pump 02 Pump / WW_LS4 WWELL'Prison Pump Station 1 WWT WET WELL Wet Well✓ WW_LS4MTR02 Prison Pump Station 1 WWT Motor 02 Motor./ WW_LS5 Prison Pump StationjDNWT Lift Station 912/2005 1:37:03PM Page 1 of 22 Rug 02 05 06:39P Diane Harris 91 2-�466-0550 P. 2 _LS5_MCC Prison Pump Si- 1 2 WWT MCC MCC +r _LS5_MTR01 '_LS5_PMP01 Prison Pump Station 2 WWT Motor 01, 01 Motor Punipl Prison Pump station 2 WWT Pump l _LS5_W W ELL Prison Pump Station 2 WWT WET WELL Wet Well _LS5MTR02 Prison Pump Station 2 WWT Motor 02 - Motor / _LS6 Public Works Pump Station WWT Pump Station WWT MCC Lift Station r MCC LS6_MCC Public Works _LS6_MTR01 Public Works Pumb Station WWT Pump 01 MOTO�R� LS6_PM001 Public Works Pump Station WWT Pump 01 Pump✓ n Z '_LS6_PMP02 Public Works Pump Station WWT Pum 1 p `� • WWELL Public Works Pump Station WWT WET MLL Wet Well _LS6 _LS61VITR02 Public Works Pump Station WWT Motor 02 Motor-' '_LS7 Shannon Drive Pump Station WWT Lift Station LS7 MCC Shannon Drive Pump WWT MCC MCC Motor '_LS7 MTR01 Shannon Drive Pump Station WWT Motor 01 Station WWT Pump 01 . Pump% '_LS7_PMP01 Shannon Drive Pump Station WWT Pump 02 Pump LS7_PMP02 Shannon Drive Pump LS7 WWELL Shannon Drive Pump Station WWT WET WELL Wet Well _LS7MTR02 Shannon Drive Pump Station WWT Motor 02 Motor '_LS8 Sullins,Dr+ve Pump Station WWT Lift Station I LS8_MCC Sullins Drive Pump Station W MCC CC '_LS8_MTR01 Sullins Dive Pump Station WWT Motor 01 Motor '_LS8_MTR02 Sullins Drive Pump Station WWT Motor 02 Motor+ d_ _. a� QreIIA V-. '. x '_LS8_PMP01 SullinsDFive Pump Station WWT Pump 01 Pump �1 %0%--Y ^a��'" , 1/ LS8_PMP02 Sullins Drive Pump Station WWT Pump 02 Pump .0 C W�� ET WELW W eL t ell � i '_LS8_WWELL Sullins ¢uvs Pump Station WWT I LS9 Pine Branch Pump Station WWT Lift Station v LS9_MCC Pine Branch Station WWT MCC MCC-, F_LS9_MTR01 Pine Branch Station WWT Motor 01 Motors r_LS9_MTR02 Pine Branch Station WWT Motor 02 Motor.- f_LS9_PMP01 Pine Branch Station WWT Pump 01 Pumper _ FLS9_PMP02 Pine Branch Station WWT Pump 02 Pump r I_LS9_WWELL Pine Branch Station WWT WET WELL Wet Well ! LS10 Henredon Pump Station WWT Lift Station, f_LS10_MCC Henredon Pump Station WWT MCC f_LS10_MTR01 Henredon PumpStation WWT Motor 01 MCC/ Motor- r f LS10 MTR02 Henredon Pump Station WWT Motor 02 Motor/ �r— r_LS10_PMP01 Henredon Pump Station WWT Pump 01 Pump,- F,i ! LS10_PMP02 Henredon Pump Station WWT Pump 02 Pump ✓ / ✓ ►_LS10 WWELL Henredon Pump Station WWT WET WELL Wet well Lift Station �_LS11 Feldspar Pump Station WWT f_LS11_MCC Feldspar Pump Station WWT MCC MCC t< i LS11_MTR01 Feldspar Pump Station WWT Motor 01 Motor J ►_LS11_MTR02 Feldspar Pump Station WWT Motor 02 motor./ r LS11_PMP01 Feldspar Pump Station WWT Pump 01 Pump LS11_PMP02 Feldspar Pump Station WWT Pump 02 WET PumpV/ Wet Well r LS11 WWELL Feldspar Pump Station WWT WELL I LS12 ' Duncan Street Pump Station WWT Lift Station. - f_LS12_MCC Duncan Street Pump Station WWT MCC MCC 4Q,�- f_LS12_MTR01 Duncan Street Pump Station WWT'Motor 01 Motor/ ar• f_LS12_MTR02 Duncan Street Pump Station WWT Motor 02 I_LS12_PMP01' Duncan Street Pump WWT Pump 01 MOtor.- Pumpi f_LS12_PMP02 Duncan Street Pump WWT Pump 02 Pumpe f_LS12_WWELL Duncan Street Pump Station WWT WET WELL Wet Well f LS13 Beaver Creek -Pump Station WWT Lift Station ✓ f_LS13_MCC Beaver Creek Pump Station WWT MCC MCC e f-LS13_MTR01 Beaver Creek Pump Station WWT Motor 01 Motor/ f_LS13_MTR02 Beaver Creek Pump Station WWT Motor 02 Motor - f_LS13 PMPbt Beaver Creek Pump Station WWT Pump 01 Pump e I_LS13_PMP02 Beaver Creek Pump Station WWT Pump 02 Pump I_LS13_WWELL Beaver Creek Pump Station WWT WET WELL Wet Well 8/2/2005 1:37:06PM Page 2 of 22 ■ Complete items 1, 2, and,3. ■ Print your name and address on the reverse so that we can return the card to you. ■ Attach this card to the back of the mailpiece, or ohIthe front if space permits. Addressed to: Richard Canipe, Town Manager Town of Spruce Pine Post Office Box 189 Spruce Pine, NC 28777-0189 Il��l�ll�llllrriliii�r��tit�lirilllltiri IIIIIIIIIII IIIIIIIII III 1IIII I IIII IIIIIII 9590 9402 2119 6132 6468 63 00011 M' 7 U X / �y�... Addressee 7ecelvedrby (Pnnf Name) C. Date Toff Deliver) D. Is delivery address different from item 1? ❑ Yes If YES, enter delivery address below: Q No WQC'sC)00< '/ 3. Service Type ❑ Priority Mail Express® ❑ Adult Signature ElRegistered MallTM1 ❑ Adult Signature Restricted Delivery Mail® ❑ Registered Mail Restricts Delivery ertified ertified Mail Restricted Delivery �� t for `'C ❑ Collect on Delivery Mercha"-a' sl ❑ Collect on Delive Restricted Delivery ❑Signature Confirinat TM ��-� fI8111 �� ( (( ❑ SlgnatureConfum [on Inman a I pestricted relive DS Fnrm SRI1 .li,iv 9nis acnt7-1;an_ro_nnn_nn-ra -2 a i'n . emil. X4A0- n-.tin Rotnrn LISPS TRACKING # ted States 4aloervice U r-- h 7 e� LLLI w o � N � CD LU CV w16 C J cr. y .5 n First -Class Mail Postage &. Fees Paid USPS Permit No. G-10 2 6468 63 -S der: Please print your name, address, and ZIP+4® in this box* m a) 8.2 00 C: O O O7 a% LINOAWIGGS NCOE"WR-WOROS 2090 U.S. �- HIGHWAY 70 SWANNANOANC28778 c 7 0 �Q a) !1'i1111'11'1I11.1.itIiIIIII III If I'1:!!IliIIII IIIIIIIli 1111111111 North Carolina Depaitmi Division'.df Water Res'ou Water Quality Operation 2090 U.S. Highway-70zi Swannanoa, NC -28778 of Environmental Quality Richard Canipe, Town Manager Town of Spruce Pine Post Office Box-189 Spruce Pine, NC 28777-0189 Il��f�ll�llllrrilni�f��frt�lirillllrl�iffliilll�flti�rrllli��ir� n _ ❑ Agent ❑'Addressee ceived • y (Printed Name) yi Dad 0 De ve elide !` differGOfrom ite �ie' Ye ES, Delivery ac7 belo❑ No CVJ O Q y 3: ffer—Vlge Type Z ❑;p'rtority Mail Express@ II I �III'I 11111111111111 IIIIIfIIIIIiI IIII 11111111111111111 'II'I11IllI[iill 1:3 Ad ❑ Aduit ignature Restricted Delivery ❑ gistered Mail Restricti 9590 9403 0672 5196 9545 79 1❑0CCeertifelivery lad Mail Res ery Return Receipt for ❑ Collect on Delivery erchandise' -- —• M-c,I1ars. n Delivery Restricted Delivery Signature Confirmation" a(I ❑ Signature Confirmation 1: 5 jfl Lj0 3 4.� 3 1a 2 4 � . �, of ,{F�estNcteid De�i�eryy i. i `Restricted Delivery rrrr 381 1,April 241`5' PSN 7530-02 000-9053� U a p �(p _ � �/_ Da q g Domestic Return Re 1 :..:!:! UNITED STATES POSTAL SERVICE First -Class Mail Postage & Fees Paid USPS Permit No. G-10 • Sender: Please print your name, address, and ZIP+4® in this box* uNogWlccs NCDEG-0WR-WQROS 1090 U.S. HIGHWAY 70 IIII SWANNANOA NC 70770 �II��UIIIIIIII�V�IBI�IIIV 9590 9403 0672 5196 9545 79 ■ Complete items 1, 2, and 3. Also complete A. Si Mure item 4 if Restricted Delivery is desired. j ❑ Agent. ■ Print your name and address on the reverse ❑ Addressee so that we can return the card to you. B. Received y (Printed Name) C. Date of Delivers ■ Attach this card to the back of the mailpiece, ._or-on—the_frontif_snace_nermits ` ss differentfrom item 1? es TMW North Carolina Department of livery address below: ❑ No � • s Environment and Natural Resources Division of Water Resources A)^ ^ _ �1V / NCDENR Water Quality Regional Operations Section (/x11 l/.��' V�`��`''JJ(,] 2090 U.S. Highway 70, Swanna , oa, NC 28778 Richard Canipe, Town Manager down. of Spruce Pine ?ost Office Box 189 Spruce Pine, NC 28777-0189 70112-1-910 0002 1967 9019 Service Type ertified Mail® ❑ Priority Mail Express - Registered Return Receipt for Merchandise ❑ Insured Mail ❑ Collect on Delivery i I Restricted Delivery? (Extra Fee) ❑ Yes h dv 9ni 11 1 1 1 flnmocfin Rphirn?RACPint . [' UNITED STATES POSTAL SERVICE • Sender: Please print your name, address, LINDA WIGGS NCDENR-DWR-WQRO, , 2090 U.S. HIGHWAY 70 SWANNANOA NC 28778 Postage &-Fqes Paid USPS Permit No. G-10 Ij Z-IP+40i his o� LA);Z\9 - -'--'------- -ix762-------- ------------------- Run Date: 04/05/2001 ( ) `_. Dat� Ca�led In: 1 Time: 11:43 Priority: ' \ Requested By: richard \ —� Ad|ress: duncan trailer park peach st. Work Requested: Sewer Date Reguire�: Note: please find inflow to sewer and stop it. manhole at last trailer on right overflowed when it rained., owner is very upset. C', Completion Date:_�� /e- Cmmpleted by: Smpe-�visor: -�' - - ' Town of Spruce Pine Work Order No: 2794 Run Date: 04/10/2001 L� Date Called In: 04/10/2001 Time: 15:00 Priority: Requested By: Mike Parker Address: Duncan Trailer Park Work Requested: Brush Pickup Date Required: 04/10/2001 Note: Mike Parker came by the Town Hall 4/10/01 with photos of manhole at W R Duncan's trailer park. The area around the manhole needs to be cleaned up,including removing paper and limed. ------------- Workers Comments: (--,,,Completion Date: c7 Completed by: Supervisor: 9 k u.� 4%� �i. : -I - - DocuSign Envelope ID: 11293686-6A01-4025-B2BF-0992B51D490C DIVISION OF WATER RESOURCES - CIVIL PENALTY ASSESSMENT Violator: Town of Spruce Pine Facility'Name: Spruce Pine Collection System Permit Number: WOCS00091 County: Mitchell Case Number: DV-2018-0067 ASSESSMENT FACTORS 1) The degree and extent of harm to the natural resources of the State, to. the public health, or to private property resulting from the violation; All SSO's may be detrimental to the environment but may not be immediately quantified. This SSO; in conjunction with another incident, did result in a Health Department posting a health risk advisory of the N. Toe River. 2) The duration and gravity of the violation; The duration and gravity to the waterbody is unknown, as noted above the River was posted for two days. 3) The effect on ground or surface water quantity or quality or on air quality; All SSO's may be detrimental to the environment but may not be immediately quantified. /� 4) The cost of rectifying the damage; Unknown, repair cost to the pipe. ' JI/q, IV IV 5) The amount of money saved by noncompliance; Unknown 6) Whether.the violation was committed willfully or intentionally; It does not appear to be either. 7) The prior record of the violator in complying or failing to comply with programs over which the Environmental Management Commission has regulatory authority; This is the 5' SSO reported since 1/2017 in Spruce Pine (different locations). No CPA's have been issued. 8) The cost to the State of the enforcement procedures. $122.97 10/18/2018 DocuSigned by: MdVA38285848C... Date G.-Landon Davidson, P.G., Regional Supervisor Water Quality Regional Operations Section . Asheville Regional Office Division of Water Resources, NCDEQ CERTIFIED MAIL #: 7016 1370 00016571 7785 RETURN RECEIPT REQUESTED - July 18, 2017 Richard Canipe Town ;of Spruce Pine PO Box 189' - Spruce Pine, NC 28777-0189 i SUBJECT: NOTICE OP VIOLATION Tracking Number: NOV-2017-DV-0182 Sanitary Sewer Overflows - June 2017 Collection System Permit No. WQCS00091 Spruce Pine Collection System Mitchell County Dear Permittee: The self -reported Sanitary Sewer Overflow (SSO) 5-Day Report submitted by Town of Spruce. Pine indicates violations of permit conditions stipulated in the subject permit and North Carolina G.S. 143-215.1. Violations include failing to effectively manage, maintain, and operate the subject collection system so that there is no SSO to the landor surface waters and making an outlet to waters of the State for purposes of G.S. 1437215.1(a)(1), for which a permit is required. Specific incident(s) cited in the subject report include the following: Total Vol Total Surface Incident Start Duration Vol Water Number. Date (Mins) Location Cause (Gals) (Gals) DWR Action. 20i700975 6/5/2017 15 Shannon Drive River Pipe Failure (Break) 1,000 1,000 Notice of Violation CrossingPump Station 201700988. 6/5/2017 30 Beaver Crk PS FM Pipe Failure (Break) 1,200 0 Notice of Violation Balifield - Riverside Park, Riverside Drive, Spruce Pine State of North Carolina Enviromnental Quality I Water Resources 20§0 U.S. 70 Highway, Swannanoa, NC 28778 828-296-4500 _ �= y - Remedial actions, if not already implemented, should be taken to correct the above noncompliance. If you have any questions, please do not hesitate'to contact Linda Wiggs with the Water Quality Section 'in the Asheville Regional Office at 828-296-4500 or via email at linda.wiggs@ncdenr.gov. Sincerely, G. Landon Davidson, P.G., Regional Supervisor Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ cCc:-- --Asheville-Region al�Offce_WQS_File-_ Central Files, Water Quality Section G:1WRMMMitchell\Collection SystemslSpruce Pine Collection SystemlSSO1NOV-2017-DV-0182.June2017 SSO.rtf State of North Carolina I Environmental Quality I Water Resources 2090 U.S. 70 Highway, Swannanoa, NC 28778 4 _. 828-2964500 - Display Reports Page 1 of 1 Select Incidents Incident ---Select Value--- Create Type Edit View I Report .................................................................................................... 4 items found, displaying all items. �1 Action Type Date Incident Permit # Region County City Liable Facility Location # Owner SSO 2005-04- 200501113 WQCS00091 Asheville Mitchell Spruce. Town Spruce Intersection 26 Pine of Pine of 17:30:00.0 Spruce Collection Greenwood Pine System and Stroud Roads SSO 2003-12- 200300513 WQCS00091 Asheville Mitchell Spruce Town Spruce Highway 15 Pine of Pine 226 S at 10:00:00.0 Spruce Collection Old 226 S. Pine System SSO 2003-09- 19767 WQCS00091 Asheville Mitchell Spruce Town Spruce PEACH 22 Pine of Pine STREET 00:00:00.0 Spruce Collection SPRUCE Pine System PINE SSO 2003-04- 18535 WQCS00091 Asheville Mitchell Spruce Town Spruce HIGHWAY 28 Pine of Pine 226 11:30:00.0 Spruce Collection S/CHARLES Pine System RIDGE ROAD :.................................................... Export options: ......................................... _..................... .............. ........... ............ Excel l -........ --............................... .............................................................................................................................................................................. XML I CSV _...................................................... ......... _.................... _............................. __.................... . ........... 's http://bims.enr.state.nc.us:7001/search.do 1/6/2006 SSO PRIORITY FACILITY SUMMARY REPORT DATE OF REPORT: August 21, 2003 FACILITY OR COLLECTION SYSTEM: Town of Spruce Pine LOCATION AND COUNTY: Mitchell County NPDES (OR WQ) NUMBER: NCO021423 NUMBER OF REPORTED SPILLS 2002 (CALENDER YEAR—FILEMAKER DATABASE): 1 NUMBER OF REPORTED SPILLS 2003 (YEAR TO DATE—FILEMAKER): 2 SSO CONCERNS (NARRITIVE SUMMARY OF THE ISSUES RELATED TO THIS COLLECTION SYSTEM —SIZE OR NUMBER OF SSOs, STREAM IMPACTS OR POTENTIAL FOR IMPACT, REPORTING CONCERNS, INADEQUATE RESPONSE TO SSOs, SYSTEM CONDITION, LACK OF ATTENTION TO THE SYSTEM, LACK OF RESOURCES, etc.): The Town has a choke point from the Beaver Creek Pump Station to the wastewater treatment plant. There are two 12-inch lines that connect to a 15 inch line. There are no known overflows from this line but the Town is controlling the flow by storing waste in the Beaver Creek pump station wet well and throtleing the pump capacity. The Town is in the process of constructing a new gravity line. Preliminary plans for a 24-inch line have just been completed and the Town plans to install it later this fall. SEWER COLLECTION SYSTEM PERMIT STATUS (INDICATE IF A PERMIT IS CURRENTLY REQUIRED AND IF SO THE CURRENT ISSUANCE STATUS ALONG WITH IMPORTANT DATES): Town has made application and draft collection permit sent to Town. Collection system permit should be issued by end of August 2003. MORTORIUM ISSUES (IS THE FACILITY UNDER A MORTORIUM OR UNDER CONSIDERATION FOR THIS ACTION FOR THE WWTP OR -SOME PORTION OF THE COLLECTION SYSTEM): NA ACTIONS UNDERWAY TO ASSESS OR ADDRESS THE IDENTIFIED CONCERNS (NOTE WORK ALREADY DONE OR ALREADY SCHEDULED): See above. PLAN TO COMPLETE ASSESSMENT OF THE SSO CONCERNS AT THE FACILITY AND TO ADDRESS THE IDENTIFIED CONCERNS (DESCRIBE THE PLANNED ACTIONS AT THIS FACILITY —INSPECTIONS, MEETINGS, ENFORCEMENTS, SOC, MORTORIUMS, SCHEDULES, etc. —AND PROVIDE PROSPECTIVE DATES FOR THESE ACTIONS TO BE CONDUCTED OR COMPLETED, PROVIDE COMMENTS ON ANY ANTICIPATED CONFLICTS THAT COULD AFFECT THE OUTCOME OF THIS EFFORT): REPORT PREPARED BY: Michael R. Parker 4-27-05;12:33PM;Town of Spruce Pine ;828+785+3014 # 2/ 5., is t 06 Form CS-S50 Collection System Sanitary Sewer Overflow Reporting Form a PART 1 This.form shall be submitted to the appropriate DWQ Regional office within live daysof the first knowledge of the sanitary sewer overflow (SSO). Permit Number G'f (WQC if active• otharwi6e use treatment plant NCN VOM Facility: s `} u O "Lie —Incident Owner ° Region:. City: C ry �1 C. County: Source of SSO (check applicable) : Sanitary se"r ❑ Pump Station SPECIFIC location of the SSO (be consistent in description from past re or documentatlon - Le. Pump Station S, r� d f +Gb� l Du Manhole, at Westall E, Bragg Street, etc.) : /fie td`y►, +C a�D t ICC�Ar1 Latitude (dagraesrmurutersecond): tonglWde(degreostminutarsecond)-— IncidentMalted.ot'Qy7c)c)(e . Time Q IncidentEixt!x` QU -& �5 Time-2 I (teen-dd-yyyy) ••,hhanm AWPM hlrmm AWPM Estimated (Round to oeanest•hour);' !. S A,�� - Estimated volume of the gallons De Wbe how the volume was determined: 'Weather t 10 /Duration condMl ons dufing SSO eve • yy.. •�r- %Yes0Nbt—t-r � 'gayd1QQYJ Did SSO reach surface Waders? Uriknowrt•. Volume reactung suifacewatels-- a lens): Surface water name: Did the SSO result in a.Tislh kilt? Yes jffNo ❑ Unknown If Yes, what is the estimated number at fish -killed -' SPECIFIC cause(s) of the SW: ❑ Severe Natural -Condition ❑ Grease ❑ Roots - ❑ Inflow and Infiltration ❑ Pump Station Equipment Failure ❑ Vandalism ❑ 'Debris in line l❑�^Poweroutage tr�Other(Please explain in Par(II) bnineate 24-hour verbal notification reported to: �rf#a-1A•t e^ di fvRGQQ- �A��— 5kgv,(fie DWq ❑Emergency Mgmt. Date (mrrr-dd�yyyj: Q %[ �� - v $ Time (hh:mm MNPM): ijd� n•� If an SSO 1s ongoing, please notify Regional office on a daily basis until SSO can be stopped. ffg"i G.S. 143-215.1 C(b), the responsible. party of a discharge of 1.000 gallons or more of untreated wastewater to surface waters shag Issue a essess release within 4$-hours of first knowledge to all print and electronic news madla pmviding general coverage in the county w core Ute schsrge occurred. When .15A00 gallons or more of untreated wastewater enters surface waters, a publio notice shell be published within 10 days and proof of publication shall be provided to the Division within 30 days. Refer to the referenced statute for further detail. The Director.' Division of Water Quafity, may take enforcement action for SSOs that are required to be reported to Division unless it is demonstrated that 1j the disphal'ge was caused by severe natural conditions and there were no feasible alternatives to the discharge; or 2) the discharge riles, exceptional, unintentional, temporary and caused by factors beyond the reasonable control of the Permi m 6rrd1br owner, and the (tscharge could not have been prevented, by the exercise of reasonable control, Part 11 must be completed to provide a justification claim for either of the above situations. This information will be the.basis `for the determination of any enforcement action. Therefore, It is Important to be as complete as possible. VVHETHE7R OR NOT PART it IS COMPLETED, A SIGNATURE IS REQUIRED AT THE END OF THIS FORM. GS-SS0 Form October S, 2W3 Page 1 -,. 4-27-05;12:33PM;Town of Spruce P,Ine jfr / r . f fVhon was the area last checke&claanad? 828+765+3014 #f 3/' ;5 Have cleaning and inspections over been Increased at this location clue to provloue problems with detuis? ❑ Yes❑ No nNA ❑NE ;r Explain: Are appropriate educational materials being developed and dstributed to prevent future similar ❑Yes© Na [INA ONE Occurrences? Cainments: Other (Pictures and a police report should be available upon request)- p- � L,O, � . be c�o�ao�praces - p .ice - fi 1v.� c-�..1 . it M A a e� �2, rrv-��, c>` ,tom •�[� , P. eA&PAI -r tO•-,J . Were adaquate equipment and resources available to fix the problem? MYaz❑ NoONA❑NE If Yes, explain: (?Opj iP—f , C.-6 e._ Ulf—] A � G? JQ ::r1. 1C �fr f � "�..J� ^%cl I- t., +0 v, A-4L If the problem could not be immediately reparred, what actions were taken to iessen the impact of the' SSO? Comments ; For DWO Use Only: DWQ Requested ari Additional Written Report: �Y� No L71dALJNE if Yes. What Additional Information is. Needed: i Comments. CS-SSO Form October 9, 2003 Page 7 4-27-45;12:33PM;Town of Spruce Pine ,;828+765+3014 # 4/ 5 As a representative for the responsible party, I certify that the information contained in this raport_is true and aaauraie , to the hest of my knowledas. Person submitting claim; , GiJ!e C,..�.( Date,j �irrJe�'eve -W� 7 Signature:Title: ��f" i-� / wvn- 'r , Telephone Number. Any additional Won notion desired to be submitted should be seat to the appropriete'Division Regional Office within five days of first kwwledge of the SSO with.reference to the ina;derrt number (the IncMent number is only generated When electrPnic entry of this form is completed, if used). t CS-SSO Form October e; 2003 4-27-05;12:33PM;Town of Sprute Pine ;828+765+3014 # 5/ 5 G NOTICE OF DISCJF "GE QF UNTREATED SEWAGE Tho Town of Spy Pine had a discharge of untreated sewage from our 'sewer main located at the intersection of Greenwood Road and Stroup Road of approximately 20,000 galIons. The temporary bypass pump (in use due. to construction of new sewer interceptor) was repaired to prevent further discharge. The discharge occurred on April 26, 2005 at 5:30 p.m. and lasted for approximately 1.5-hours. The untreated wastewater' entered the North Toe River of the French Broad River basin. This notice was required, by North Carolina General Statutes Article 21 Chapter 143:215.C. Formore information . contact Richard Canipe,.Town Manager at (W)765-3000. r. 4-27-0�;12;33PM;Town of spruce Pine T ;$28+765+3014 # 1/ 5 P.G. 8oX 489 SM= F" Pe W. 28777 po5 t U3 W-M. AW 12-16-03; 4:18PM;TOWN OF SPRUCE PINE P.O. Box 189 Spruce Pine,'N C 28777 '(828)765-3000 3; 1 ­ (828)765-3014 FAX Fe& ;8287653014 To: From: ►k?'I� CA-VV L Fwc Pages:' Phones Date: t Re: CC: 13 Urgent 13 For Ripdew 13 Please Comment ❑ Please Reply Please Recycle a 2- t 6-03 ; 4 : 1 S,pkL;,Zz0WNgOF-SPFTL'7"C '1-NE ; 828765301 4 # 2/ 9 DEC 7 2003 Form CS-SSO Collection System Sanitary Sewer.Overflow'Reporting Form WATER QUALITY SECT&I :::-:_::<::: _:.:::•::�:::::::::., I ASHEVILLE REGIONAL QFFIC_-- PART This form shall be submitted to the appropriate DWQ Regional Office _within five days of the first knowledge.of the sanitarysewer overflow (SSO). - Permit Number : A ap a / C 3 (WQCS# if active, otherwise Facility: ' 2 ' t��. ' use treatment'piant NC/WQ# I1 5,13 �3y� Incident # Owner. "J N Region: City': T A ' ' `� e ,tit a.7 ?• i �i J County: / Source of SSO (check applicable) : Sanitary Sewer �. Pump Station SPECIFIC Iocation of the SSO (be consistent in description from past reports or documentation - i.e. Pump Station 6, . Manhole at Westall & Bragg Street, etc.) 2 of f -S' 1 0/-6 7 6 5. Latitude (degrees/minute/second):. Longltude(degrees/minute/second)• Incident Started Dt: °� G Time v �,. End Dt a f Time - U47—( If • (mm-dd-yyyy) hh:mm AM/PM •Incident (mm-dd-yyyy) hh:mm AMlPM Estimated volume of the-SSO: �� gallons Estimated Duration (Round to nearest hour):' Describe how the volume was determined: 57Ss A �� � � e Lc S �' �5 ©r�! G e Weather conditions during: SSO- event: Did SSO reach surfaca'waters?.:. 0 Yes 0 No � Unknown Volume reaching surface waters (gallons):. Surface water name:' Did the SSO'result in. a fish kill? Yes ONo Unknown : If Yes, what is the estimated number of fish Killed? SPECIFIC' causes) of the SSO: 0: Severe Natural Condition Grease Roots Inflow and Infiltration Pump Station Equipment Failure 0 Power outage . �. Vandalism. Debris in fine , Other (Please explain in Part II) Immediate 24-hour verbal notification reported to: — ��t,Lp��✓ �jy`� E2rDWQ 0 Emergency Mgmt.' Date (mm-dd-yyyy):1;ele �aQ Time (hh:mm AM/PM): If an $SO is ongoing -'please notify Regional Office on a dally basis until SSO can be stopped. Per G.S. 143-215.1 C(b), the responsible party of.a discharge *of 1,000 gallons or more of untreated wastewater to surface - waters shall issue a . press release within 48-hours of first knowledge to all print and electronic news media providing general' - coverage in the county where the discharge occurred. When 15,000 gallons or more of untreated wastewater enters surface waters, a public notice shall be published within 10 days and proof of publication shall be provided to the Division within 30 days... Refer to the referenced statute for further -detail. ' The Director, Division of Water Quality,'rriay:take enforcement action for SSOs that are required to be reported to Division unless it is demonstrated that: 1) the discharge was caused by severe natural conditions and there were no feasible alternatives to the discharge; or, 2) the discharge was exceptional, unintentional, temporary and caused by factors beyond the reasonable control of the Permitte'e. and/or owner, and the discharge could not have been prevented by the exercise -of reasonable control. Part II must be completed to provide a justification claim for either of the above situations. This information will be the basis for the determination of any enforcement action. Therefore, it is important to be as complete as possible. ' J WHETHER OR NOT.PART II IS COMPLETED, A SIGNATURE IS REQUIRED AT THE 'END OF THIS FORM- CS-SSO Form . October 9, 2003. ge 12-16-03; 4:18PM;TOWN OF SPRUCE PINE - _ ;8287653014 # 3/ 9 Qom_ Form CS-SSO ;::.:•: •�.�� .. '. , . -Collection System Sanitary Sewer Overflow Reporting Form ..........::::::::;.::. PARr• I I ANSWER THE FOLLOWING QUESTIONS FOR EACH RELATED CAUSE CHECKED IN PART I OF THIS.FORM AND INCLUDE THE APPROPRIATE DOCUMENTATION AS REQUIRED OR DESIRED COMPLETE ONLY THOSE SECTIONS PERTAINING TO THE CAUSE OF THE SSO AS CHECKED IN -PART I In the check boxes below, NA = Not Applicable and NE = Not Evaluated A HARDCOPY OF THIS FORM SHOULD BE SUBMITTED TO THE APPROPRIATE DWQ REGIONAit OFFICE - UNLESS IT HAS BEEN SUBMITTED ELECTRONICALLY THROUGH THE ONLINE REPORTING SYSTEM' Severe Natural Condition (hurricane, tomado, etc.) Describe the "severe natural condition" 'In,detail. . How much advance warning did you have and what actions were taken in preparation for the event? ' _'Comments: Grease (Documentation such as cleaning, inspections, enforcement actions, past overflow reports, educational -material and distribution date, { etc. should be available upon request.) When was the last -time this specific line (or wet well) was cleaned? Do you have an enforceable grease ordinance that requires new or retrofit of grease trapsrjnterceptors? Yes❑ No ❑NA❑NE Have (here been recent inspections and/or enforcement actions taken on nearby restaurants or other ❑Yes❑ No ElNA❑ NE nonresidential grease contributors? Explain. Have there been other SSOs or blockages In this area that were also caused by grease? ❑Yes❑ No❑NA ❑NE When? If yes, describe them: Have cleaning and Inspections ever been increased at this location? ❑Yes❑ No ❑NA ❑NE Explain. CS-SSO Form October 9, 2003 Page 2 12-16-03; 4:18PM;TOWN OF SPRUCE PINE Have educational materials about grease been distributed in the past? J` When? and to whom? Explain? ;8287653014 # 4/ 9 ❑Yes❑ No❑NA❑NE If the SSO occurredat a pump station, when was the wet well and pumps last checked for grease accumulation? Were the floats dean? . • ❑Yes❑ No ❑NA ❑NE Comments: Roots . . I Do you have an active root control program? Yes No ❑NA ❑NE . Describe :.: .. Have cleaning and inspections ever been increased at this location'because of roots? ❑Yes❑ No ❑NA ❑NE Explain:-. - What corrective actions have been. accomplished at the SSO location (and surrounding system if " . associated with,the SSO)? What corrective actions are planned at the SSO location to 'reduce root intrusion? .. Has the line been smoke tested or videoed within the; past year?.. ❑Yes❑ No ❑ NA ❑NE .If. Yes, when? Comments: Inflow and Infiltration. - Are you under. an SOC (Special Order by Consent) or do you have a schedule in any permit that ❑Yes❑ No ❑NA ❑NE addresses VI? CS-SSO Form October 9, 2003. Page 3 12-16-03; 4-18PM;TOWN OF SPRUCE PINE ;8287653014 # 5/ 9 Explain if Yes: What corrective actions have been taken to reduce or eliminated & I related overflows at this spill location within the last year? Has there been any flow studies to determine 1/1 problems- in the collection system at the SSO locat.ion? . ❑Yes❑ No ❑NA ONE If Yes, when was the study completed and what actions did it recommend? Has the line been smoke tested or videoed within the past year? ❑YesO No ❑NA ❑NE If Yes, when and indicate what actions are necessary and the status.of such actions: Are there III related projects in your Capital Improvement Plan? ❑Yes❑ No ❑NA ❑NE If Yes, explain: Have there been any grant or loan applications for UI reduction projects? ❑Yes❑ No ❑NA ❑ NE _ If Yes, explain: . ' Do you suspect any major sources of inflow or cross connections with storm sewers?.' ' ' ❑Yes❑. No ❑ NA ONE If Yes, explain: Have all lines contacting surface waters in the SSO location and upstream been inspected recently? OYes❑ No ❑NA ONE. If Yes, explain What other corrective actions are planned to prevent future III related SSOs at this location? Comments: Pump Station Equipment Failure (Documentation of testing, records etc., shoal be provided u 0on request.) What kind of notificationtalarm systems are present? Auto-dialer/telemetry (one-way communication) ❑Yes CS-SSO Form October 9, 2003 Page 4 m 12-16-03; 4:18PM;TOWN OF SPRUCE PINE ;8287653014 # 6/ 9 Audible Dyes Visual SCADA (two-way communication) Emergency Contact Signage Other Describe the equipment that failed? What kind of situations trigger'an alarm condition at this station (i.e.'' ump failure, power failure, high water, etc.)? _ ❑Yes ❑Yes ❑Yes ❑Yes Were notification/alarm systems operable? ❑Yes❑ No ❑NA❑NE If no, explain: If a pump failed, when was the last maintenance and/or inspection performed? What specifically was checked/maintained? If a valve failed, when was. it last exercised?' Were all pumps. set to.alternate? ' ❑Yes❑ No ❑NA ❑NE Did'any pump show above normal run times prior -to and during the SSO event? . ❑Yes❑ No ❑NA ❑NE Were adequate spare parts on hand to fix the equipment (switch, fuse, valve, seal, etc.)? : ❑Yes❑. No ❑NA ❑NE Was a spare or portable pump immediately available? ❑Yes❑ No ❑NA❑NE ' If a float problem, when were the floats Iast tested? How? If an auto-dialer.or SCADA, when was the system last tested? How? Comments: CS-SSO Form ' October 9, 2003 page 5 ' 12-16-03; 4:18PM;TOWN OF SPRUCE PINE ;8287653014 # 7/ 9 Power outage (Documentation of testing, records, etc., should be provided of alternative power source upon request.) = What is your alternate power or pumping source?_. 'Did it function properly? ❑Yes0No ❑NA ❑NE Describe? :. When was the alternate power or pumping source last tested -under load? If caused by a weather event, how much advance warning did you have and what actions were taken to prepare for the event? Comments:. Vandalism Provide police -report number. Was the site secured? ❑Yes❑ No ❑NA ❑NE ` If Yes, how? Have there been previous problems with vandalism at the SSO location? ❑Yes❑ No ❑NA❑NE If Yes, explain: What. security measures have been put in place to prevent similar occurrences in the future? ❑Yes❑ No ❑NA❑NE Comments: Debris in line (Rocks, sticks, rags and other items not allowed in the collection system, etc.) What type of debris has been found in the line? How could it have gotten there? //r �• /f oc IL Are manholes in the area secure and intact? t11,19-7 t.p d `14-V 124�0 14eC. AP4_!t-�lU 2Y O No ❑NA ❑NE ' CS-SSO Form October 9, 2003 Page 6 I 12-16-03; 4:18PM;TOWN OF SPRUCE PINE _ ;8287653014 # 8/ 9 When was.the area last checked/cleaned? Have cleaning and inspections ever been increased at this location due to previous problems with debris?' El Yes❑ No ❑NA ONE Explain: Are appropriate educational materials'being developed and distributed to prevent future similar ❑Yes❑ No ❑NA LINEoccurrences? Other Pictures and a polic,6 report should be available upon request.) Describe: Were adequate equipment and resources available to fix the problem? I.No If Yes, explain: If the problem could not be immediately repaired, what actions were taken to lessen the impact of the sso?.... I . " Comments: Y For DWQ Use Only: , DWQ Requested an Additional -Written Report: ❑Yesu No❑NA❑NE If Yes, What Additional Inforrnagon is Needed: Comments: i 12-16-03; 4-18PM;TOWN OF SPRUCE PINE _ ;8287653014 # 9/ 9 As a representative for the responsible party, I certify that the information contained in this report is true and accurate to the best of my knowledge. Person submitting claim: Date: Q Signature: • z Title: f .�/ •crP��.._, Telephone'Number. Any additional information desired to be submitted should -be sent to the appropriate Division Regional Office within five hays of first knowledge of the SSO with reference to the Incident number (the incident number Is only generated when electronic entry of this form - . Is completed, if used). i CS-SSO Form October 9, 2003 Page 8 Section 8: SSO Enforcement Guidance EXHIBIT B: SSO EVALUATION FACTORS "cident M Permittee: -76—uW0 WS,09,4, O Date of Incident: 'D ARE ANY OF THESE FACTORS A BASIS FOR PROCEEDING WITH FURTHER ACTION? FACTOR YES NO COMMENTS Volume/Duration Surface Water • Sensitive/High Priori��',�',! �2 (SA ORW W§",� etc.) . ....... J Damage Fish Kill -IS • Property • Public Health Concerns Weather Conditions and other Uncontrollable D67— Factors • Severe Natural Condition (hurricane, lee,, Vandalism/Third Party Repetitiveness Same Location (past 24 mo) Repetitiveness Same Cause (past 24 mo) Preventability 0 Proper O&M 0 Storm Preparation System -wide Compliance (past 24 mo) • Similar causes multiple instances • Previous actions like NOVs I Enforcements • Failure to react to Technical Assistance from Division Response to Spill Adequate time & cleanup) 2, Proactiveness d • Active programs for 1/1, grease, roots, etc. • CIP program CONCLUSION: Does overall evaluation or No Action E] Action any one single factor result in the need to Staple this to report NOV SOC Pending proceed with action? File Enforcement Moratorium Close out incident in BIMS No Action Additional Comments: IZA /Mtn U. Form completed by Date -za'/` 17 Page 9 of 9 10/03 9-24-03;10=39AM;TOWN OF SPRUCE PINE P.O. Box 189' Spruce Pine, N C 28777 ` (828)765-3000 (828)765-3014 FAX FaX Town of Spruce Pine To: rn' �1 �A !Z ��� �- From: A Fax: a �J - (p L� S Pages: Phone: Dates ' - a: 4 -O Re: CC: ❑ Urgent ❑ For Review ❑ Please Comment ❑ Please Reply i7 Please Recycle 0 ? 4 , p003 9-24-03;10:39AM;TOWN OF SPRUCE PINE ;8287653014 # Sewage Spill Response Evaluation: (page 1 of 2) r� r Permittee ���/.J JG:2ll Ike Number ®C-A 1 Lk 11 _ CountyAll-Alt Incident Ended: (Date/Time)-'O'a /ZA/ Estimated Duration (Time) lil�Xdyrll-z1�t/ First knowledge of incident: (Daterrime) Estimated volume of spili/bypass L4V - Xsya W-A/ gallons. Show rational for volume. If spill is ongoing, please notify Regional Office on a daily basis until spill can be stopped. Reported to: (Date/time) 457? -Q 2 --)-3 23 Name of person Weather conditions: rj'e.912- Source of spill/bypass (check one): —,L-.$aniiary Sewer Pump Station WWl'P Level of treatment (check one): None ' kPrimary Treatment Secondary Treatment Chlorination Only Did spill/bypass reach surface waters? Yes ��N}}o (If Yes, please list the following) Volume reaching surface waters? U �aln ui ►> > gailo s" � ��'�`� e, Name of surface water �O ►.�-�(L //►► �y -� nf• Did spilUbypass result in a fish kill? Yes !/No If Yes, what is the estimated number of fish killed? SEP 2 4 2003 f c, Please provide the following information: • • • • . ..I / + �'I W" / 1L w i 3. Did you have personnel avaiiabie to perform'initial assessment 24 hours/day (including weekends and holidays)? Yes _�No 4. How long did it take to make an initial assessment of the spillover low after first knowledge? Hours 40 - Minutes How long did it take to get a repair crew onsite? Hours 020 0 Minutes Revision#1 6/11199 !t?Y." Lr7a `eff-e/zY Sewage Spill Response Evaluation: ((�} (Page 2 of 2) ^- Permittee 7a c ,j�2rL( *;nit Number 00 kf t4 d-a County S. Action taken to contain spill, clean up waste, and/or remediate the 6. Were the equipment and parts needed to make repairs readily available? Yes,_ No If no, please explain why: 7. If the spill/overflow occurred at a pump station, or was the result of'a pump station failure, was the alarm system functional at the time of the spill? Yes No _&�f 'if the alarm system did not function, please explain why: 8. Repairs made are: Permanent _� Temporary Please describe what repairs were made. If the repairs are temporary, please indicate a date by Which permanent repairs will be completed, and notify the Regional Office within 7 days of the permanent repair.d,�� Lc/iJ �- 9. What actions have been made to prevent this discharge from occurring gain in the future? 0 10. Comments: Other agencies notifed: Person reporti s dit/b as c� Phone Number. "7 3cJl� Signature Date: lP' a �J For DtNt1 Use Only:----- DWQ requested additional written report? Yes _1/^No N� If yes, what additional information is needed? - "Requested by Revision # 1 6111 /99 I 4-29-03;12::54PM;TOWNy}OF SPRUCE PINE �t ;8287653014 # 2/ 2 ���; .. i'l.4t..�.. ,tt .L ,�e'.�11. �__ �:f"A ��'-fi =�1 �A�' ..i.... .. .: • . i. t, _ yr: 1� S. iitary Sewer Pumn uitj n atad WWT, PAPoR nnt r. _ At pass (PteasE PFnrm Type Use tacttmcnLs i£'Needcd ) ''Permit-Nrimber:­- 0d- a l 'Incident Started: Dace �'a� -� County: Time Incident Ended: Date ' '� r- 4)3 Time ) Source of SpillBypass (Check One): JWSanitary Sewer O.Pum Station O Wastewater Treatment Plant Level of Treatment (C1icck.One): O one O Primary Treatment O Secondary Treatment O Chlorination Only Estimated Volume of SpiJI/Bypass. /( 1000 414A volume must be given even if it is*a rough estimate Did the Spill/Bypass reach the Surface Waters? O Yes O No If yes, please list the following: Volume Reaching Surface Waters: Ua� Q �� ace Water Name: SH t^2 ec�$ Did the SpillBypass rcru1t in a Fish Kill? O es No LtocatiglZst;th� i11B,y •�titi- L&5711 A A �ai1RC of the Pitl/B.�rts� r . Pds s F 6 j y ��. ��.�.t � sad L. • ,� It3 PLx-b r v o -b UL �a- '—' 2 A 4-- 0—,La� ) r .v .p • ._CiCltll_Ut? Wnstc_and Rcinediate the site: p 5i r S S f , .1) �•¢r�e �Cr �c ` �,¢�[2� `Y k/'.45 4 6ca'd2 b e r o L,( ,v' AeyV4,.,-W 'ems u Arta to ' �kcr} �r Presn�_t�C_Ttt1iC11 tU PIrYCnt I' rt t S � t . Lj0 �G� �Q Dillti at tlri ;1it111; � J rt1 t� r-21 rF►� �t t /9/Z I ,V& �3c-crL 01 S E5VIL , l� ram, / J � ✓vt. � -h �.s 1 � � $,� ��' 0(her Agencies Notified: Pcrson Rcperrti ---•-------Sf1i1i/13yPa«:_ ChAa-D CA S-Phone Number: - --------------Date:--------------------------------------For I)WQ Use Onl.:------------- ---_ �---�----'-•---7�-G----�S--3----�---G- tl -�---�-3--- Rclx�rt Tukcn by: Report Taken: Da(c r _i I)WQ Requeslcd an Additions! 1t riltcn Kcpc►rt: JO Ycs If Yes -What Additional Inforrtration is Needed: V �'✓'+�r1'�—^ � ,: 4-29-03;12:54PM;TOWN OF SPRUCE PINE ;8287653014 # P.O. Box 189 Spruce Pine, N C 2877.7 (828)765-3000 (828)765-3014 FAX Fax Town of Spruce Pine To: / l 7( 4,:�, /iC ��C. _ From: Fax2-Z/Pages: Phone: Date:j�/d� Re: ��� ! CC: C�Urgent ❑ For Review ❑ Please Comment ❑ Please Reply ❑ Please Recycle 0 0 4-29-03;12:54PM;TOWN OF �.=�v6JCE PINE 8287653014 # 2/ 2 7' 1% . . ..... UZ J' PITMn Qfn* IL;_ acy-Sewgr L ass (Please Print or. Type: Use Attachments hme. s 11 Needed') kY j" U rMl .1ildde''nt Started: Date 4_.1y -63 County: C a- meL1 _71/hIM, Incident Ended: Date -:1 r- 6.3 2 0 Source of Spillffiypas.,; (Check One): JOS 111ary Time _L U_ :% ar-wer UJIUM2 Station Wastewater Treatment Plant Level of Treatment (Check.Onc): 0 None 0 Prim Treatment J.110ary Treatment n Chlorination —0njj Estimated Volume -of Spill/Bypass: - dQVY 10G)QcjA s(A volume must be given even if i(is*a rough estimate Did the Spiil/Bypass reach file Surface Waters? OYcs ONo. If Yes, Please list the following. Volume Reaching Surface Waters:. 11A)XwVA) Lk ffkUdace Water Name: Did the Spill/Bypass'result in a Fish Kill? 0 XNo,es No _ _ 1,6016an QI& Sj2illmyp�-_ /A3 118V Rn 3 s F b pp_'p—S S ;-La—e- � C'j -As 3:(L— _6 5p L 5 "10 tom., L4 --r. R.. &A re— -5 C_R_Q_� Action Takerl of pj D Din don- '44 ./j av t5 0,5 Other Agencies Notified, Person RcportiM spill/13 &!j,!!urr . I - - - - - - - - - - - - - - - - - firly use Only: - - - - - - - - - -A - - - - - - - - - - - - - - - - ReWil Taken by.- I)WQ Requested an Addition.,] ",I-ij (en Rcport: If Iles, Addi4nal Inforinalion* is N ' ecded: Phonc Number:, P-)J" - ........ ....................... _­ ------------- R4MI Taken: Date 16'Vc.k ONo­j mountain view -,orrectvo I Insbtution :f P.O. Box 708 Spruce Pine, NC 28777 Nk. th CarolinaD.O.C. y 828-755-0956 828-765-1457 Fax- - TO: M� lee- pmrcze From: L C Uyarc Fay: A. (Ba's -. ws1-- (yWS2, Pages: ro gj&b&j al S� ,df BFione:(�e1$ `a►5� (p'�0$ Date: E3 Urgent OFor Review ❑ Please Comment ❑ please Reply ❑ Please Recycle t' • Comments: pLl o9 S(Ip = TL et Selz TO'd Z2: TZ TOOZ ZT J12W I 8Z6ZS9L8Z8T x>?d ' IO MMA N1W .%.J. UQX (-n Soruce Pine. NC 2877- 523-765-0956 228-765-1457 Fax.! 1h Carolina D.O.C. To: VAPjRf3EeJt pig. From: � L, : CLo& Fax: pages: Phone: 1q) "7 1 (p -3 4 Z7 Date. .C Re. CC: - �rUent OForReview C1 Please Comment IJ Please Rdply 0 Please Recycle 0 Comments: -765 N 540 EO*\S�010 =625 SZ 4 ArGrir= 'OCSPWS1 EVOJL)4TeN T % > ZO'd Z9-: TZ TOOZ- 6T J2H &6ZS9ZKK:xEiJ ID MMA NIW Sewage Spill Response-Evaluatr _16 (Page 1 ) Permitee Permit Number County Q1�� Incident Started: (Dateriime)3 b v / 4:4SP11141ncident Ended: (Datefrime) 3 (o ei 1 0:35 If -spill is ongoing, please notify Regional Office on a daily basis until spill can be -stopped. _ Reported to: tA04JT. t?p& ' WA RpAto (Oate/time) 31(oii)I Z WSJ weather conditions: SNDUS c4A W tjL-S - *tr" w►� 6 gQ1AIt Source of spill/bypass (check one): —Sanitary $ewer ✓ Pump Station INItViP Level of treatment (check one): 4ONone zPr1mary Treatment Secondary Treatment _Chlorination Only L tOW Estimated volume of spilll6ypass CUOKuW gallons. Show calculations. Did spill/bypass reach surface waters? Yes •_t!�'Nc (If Yes, please list the following) Volume reaching surface waters? gaI(ons Name of surface water Did spill/bypass result in a fish kill? Yes No If Yes, What is the estimated number of fish killed? Please orovide the followina infcrrna:ion: 3. Did you have personnel available to. perform initial assessment 24 hours/day (including weekends and holidays? Yes ,No 4. How long did it take to make an initial assessment of the spill1overflow after first knowledge? Hours L Minutes How long did ii take to get a repair crew onsite? Hours Minutes 20'd ' 22:Z7, ZOOZ ZI upW 8Z6ZS9Z8ZK :XPJ IO M3IA N1W "Sewage Spill Response Evali'_ : ,on: (Page Z) P erm ite e S. Action taken to contain Permit Number County_6_ Ill, clean up waste, and/or remediate the site: 5, Were th�uipment and parts needed to make repairs readily available? Yes No if no, please explain why: 7. If the spilifoverfiow occurred at a pump station, or was the result of a pump station failure, was the alarm system functional at the time of the spill? Yes _w No If the alarm system did not function, please eAllain why: 8. Repairs made are: Permanent ✓ Temporary Please describe what repairs were made. If the repairs are temporary, please indicate a date by which permanent repairs will be completed, and notify the Reaicnal Office within 7 days_ of the P%manent repair. We. CNO l[LLx_ AN __ Atj 'Wei& DR — actions actions have been made to revent this discharge from cccuring again in the future? `r. Comments: Other agencies notifed: N CC DOC EN61•nrL-WAa k k� sqj, Ne- a761)q Person reporting spifUbypass:��e2� L. C1 Phone Numbe S?Z!Q u5-09'SG Signature 2L� pate: 3 !o p For RWQ Use Only:__-- DWQ requested additional written report? Yes No If yes, what additional information is needed? Requested by b0 'd 12: 7 TOOZ ZT upW 8Z6ZS9Z8ZK : xed I9 MIA N1W SPR(/C�A' yF y�'4TH CA��� January 24, 2003 Town of Spruce Pine, North Carolina Mr. Mike Parker NCDENR 59 Woodfin Place - - - - Asheville, NC 28801 Dear Mike, Per our telephone conversation on Tuesday, January 21, 2003, the following describes the situation at English Creek, near the Ingles Supermarket. We were made aware of a possible sewer leak on Friday, January 17, 2003. Upon investigation, our Public Works staff determined that a hole in the twelve -inch sewer line was allowing wastewater to leak as well as creek water to enter the system. Until this time no indications of a problem in the area of the leaking pipe existed. The property recently changed hands and the new landowner discovered this situation. We have no estimate for the amount of spillage or inflow involved with this discovery. The line has been replaced and is no longer leaking. Thank you for your assistance in this matter. Please call if you have questions or comments. Sincerely, lit �• L� �CC" (.o'er% Richard Canipe Manager Town of Spruce Pine JRC/db 11 Post Office Box 189, Spruce Pine, North Carolina 28777-0189 Telephone: (828) 765-3000 Fax: (828) 765-3014 Website: www.sprucepine.org P.O. Box 189 138 Highland Avenue Spruce Pine, NC 28777 May 10, 2002 Mr. Mike Parker 59 Woodfin Place Asheville, NC 28801 Dear Mike, Phone: (828) 765-3000 Fax: (828) 765-8141 Email: townhall@m-y.net MAY 1 3 Per our telephone conversation March 12, 2002, the situation with the Sparks Road wastewater pump station has been resolved. D.O. Creaseman Company of Asheville was contracted to repair the line. By using directional boring they were able to replace the line under the North Toe River with a new 4-inch line. All work was completed on Thursday May 2, 2002. During the construction Mayland Septic Service pumped the station daily to prevent further spillage. Thank you for your assistance in this matter. Sincerely, i ichard Canipe Town Manager RC/tb P.O. Box 189 138 Highland Avenue Spruce Pine, NC 28777 March 14, 2002 Mr. Mike Parker NCDENR 59 Woodfin Place Asheville, NC 28801 Dear Mike, Phone: (828) 765-3000 Fax: (828) 765-8141 Email: townhall@m-y.net Per our telephone conversation on Tuesday, March 12, 2002, the following describes the situation at the Sparks Road Wastewater Pumpstation. We were made aware of a possible sewer leak on March 5, 2002. Upon investigation, our Public Works staff determined that the three-inch line that should cross the river has been washed away. Several area residents maintain that the line has been gone for approximately four years. Until this time no indications of a problem in the area of the missing pipe existed. This small pumpstation serves only fourteen to sixteen residences. The reduction in flow to the wastewater plant was insignificant, so no warning flag occurred. The pumpstation is being pumped daily to avoid further spillage into the Toe River. We have engaged McGill and Associates Engineering of Asheville to develop the plan to repair / replace the line. Two options are being considered, directional boring or open -cut method of pipe replacement. Mr. Harry Buckner of McGill will contact you as soon as the most practical and effective solution has been determined. Thank you for your assistance in this matter. I will keep you informed as progress is made. Sincerely, z �'/L'aj a��_ , Richard Canipe Manager Town of Spruce Pine JRC/db MAR 1 5 2002 'O' S'CTIOI�i M 6-29-01; 8:59PM;Town of Spruce Pine 1J ;8287658141 # 2/ 2 IN .'� r`.i.. F, 77 •'r,;: is ` '•.@ . r:. Yiffitary SewetArion : a ass Report Fom (Please Print or 3 pe - Use Attachments if Needed l Eermtticc: ='w ,S� 2� Q� - pr !� permit i`Ititiibcr O o d I �- r _a.�_ County: 1� " Incident Stiked: Dale Q (_ Time P� Incident Ended. Date d!de?r-01_ Tune Source of SpillBypass (Check One): ,Sanitary Sewer Purrs Station O Wastewater Treatment Plant Level of Treatment (Check.One): FeMonc O Primary Treatment O Secondary Treatment O Chlorinatian Onh Estimated Volume -of Spill/Bypass: ° ' /Q-0 ; volume must be given even if it is a rough eslima[c Did the Spill/Bypass reach the Surface Waters? es No If yes, please list the following: Volume Reaching Surface Waters: p' - Surface Water Name: Did the Spill/Bypass result in a Fish Kill? No I oc7tion of the Sr il� [/9•JP_t�s: pillmu.-tsx: F _! -� • 1kscribc the Replrirs Muds - AJ ova- ,6 - r� Action Taken to lilnr� ti1,01 Ckju[ 4LW sate and Rcrosdimg the Ste, PU'MAO-k t�+,Ajt� qA-(,t 62-4 0 cA-+- wei w-o-11 iq-Ajb 0- p .ry ` aD t W-- A 4kig— 4-vPL O u ✓i. "t, � C v� a n2 c vt� 1 vi/ •i=l.Lr.-11.w\emu .v � iL r� a► a-�iiLLl< i2+! 111 lll��l1�1 f1CW - ��; % � � .� �` �. (�✓� 7� T `— S � /"^•• � `ELK-�1� 7�'—! ✓ -Ci Other Agencies Notified: Pcrtan Rcpwin2 sill] I(B v(ra.w Phone Number: _9 )L-V -- ja S -3 per) --•- - --- -------------------------- =!� ------_--------------- DaEc: For [M'QUsc Only; 4--% -�— Ot.il Report Taken by: Reporl Taken: Date T1111C U«'Q Requolcd an Additional 1ti'rittcn RgKni: If Yes. 'A'hn1Additional lnfwrtration is Needed: 6-29-01; 8:59PM;TOWn of Spruce Pine ;8287658141 # 1/ 2 Town of Spruce Pine 106 Highland Ave P O Box 189 Spruce Pine, NC 2 8777 Voice: 828-765-3000 Fax:828-765-8141 Facsimfle Tn"mittl To: M l l� PA 2 I( -e 2 Pax: d .a -A 1 From: R`dv"41L!D y cL Date: C1 � Re: ( 5 � l .) �� Rages: CC: ❑ Urgent O For Review O Please Comment ❑ Please reply ❑ Please Ragc1e 4-19-01; 3:32PM;Town of Spruce Pine ;8287658141 2/ 2 �. y. Y. A{�/ C R ^s5 -_��--�.,'V',- :� �anitary Sewer PumR S��ori arl•��SniI_.I n Rypass Reborn, ���-,: '•'=`•= � `' ' - ' (Please Pnnt or. Type -Use Artachmen[s �f . - : P.eriil't#ee: �'� w� P a.-�l 2�. - - P1 ry � =Fermi t Nrimber: O o •d I �J J-Count 1 � - 7ncident Started: Date �l - i$ - d J Time Incident Ended: Date `%/I'-0I Time Source of SpillBypass (Check One): Sanitary Sewer O Pump Station ~� O Wastewater Treatment Plant Level of Treatment (Chcck'.One): one O Prim Treatment O Secondary Treatment O Chlorination Only Estimated Volume -of Spill/Bypass: POy —S D(: /4&A volume must be given even if it is.a rough estimate Did the Spill/Bypass reach the Surface Waters? es O No If yes, please list the following: Volume Reaching Surface Waters: 2 pv i,i9 (:S Surface Water Name: Did the SpilVi3ypass result in a Fish Kill? 10 Yes .. o Location of the S in lI/B 1pdS _ ss: Dcscri be Le Rcaairs A411LI P t P e mil- �Ci�IS�GC.�I Action T Ik n to Con 111�11,- A-w e4 •_. A ACLion TLkcn nr Pr•rVn��t�ke_f_ukctt (U I'1rYcnt F tt r S i11r a( hjc I ^nrinn• S u (Ze_ Nv -cam- 24,2-QA c ©CCu2S5 Other Agencies Notified: ' Pcnon Rcpottin Spitl/ Sinatutr- _ �- For 1M'Q Use Onl,.------------------------------------------------------------------ ��= _--------- ----- � -------------- Ora! kcpc)ri Taken h} : Rcpon Taken. Date Timc DWQ Requested an Additional Wr•iacn Report: h �7ca h No' j If Ycs, "'hat Additional Information is Nce'dcd: _ i P.O. Box 189 138 Highland Avenue Spruce Pine, NC 28777 April 18, 2001 Mr. Mike Parker NCDENR-Division of Water Quality 59 Woodfin. Place Asheville, NC 28801 Dear Mike, Phone: (828) 765-3000 Fax: (828) 765-8141 Email: townhall@m-y.net It Qf(�� I, F- 11i APR 9 2001 f f This letter is in response to your visit in Spruce Pine on Tuesday, April 10, 2001. Please be advised that our Public Works staff has located and corrected the problem that caused the manhole to overflow in the William Duncan Trailer Park. Attached you will find work orders and photographs showing the area that was cleaned and limed. Also, you can see the broken sewer line that was allowing the excess inflow of rainwater. We have been monitoring the situation and as of this time there have been no more problems. Please let me know if I need to take further action on this matter. Sincerely, r i / ` % Richard Canipe Manager Town of Spruce Pine Enclosures (4) JRC/db 4- 9-01; 4:33PM;Town of Spruce Pine ;8287658141 # 1/ 2 Town of Spruce Pine 106 Highland Ave P O Box 189 Spruce Pine, NC 28777 Voice: 828-765-3000 Fax:828-765-8141 Facsimile Tmoniftal To: f^� 1 (�`�2 Fax: Y a -- S� — (� (4 s FMM:Rk ckA42b ' C4 -43 0.P Date: Re: c� P� (( Pages: CC: ❑ Ulatt ❑ For Raview ❑ Pieria Casement ❑ Pieria Re* ❑ pM2= Recycle Nab= L. 4- 9-01; 4:3SPM;Town of Spruce Pine ;8287858141 # 2/ 2 K-Vrm ee ' � �� {r .✓uv. .. . PennirNtimber '_ OQ LZ `/90 CountyA &41e 'Iitcldent&iited: Date _4' - ( Time :02 Incident Ended: Date 6f-9-01 Time q Bounce of SpilUBypaxs (Check One): O Sanit Sewer um Station O wastewaterTreatment Plant Level of Treatment (Cltcck .One): O None O Primary Treatment O Second ary Treatment O Chlorination Onh Estimated Volume -of SpillBypass� : �``l (A volume must be given even if it is'a rou h estima Did the Spill/Bypass reach the Surface Waters? O Yes No If yes, please list the following: 1; tc Volume Reaching Surface Waters: If Water Name: Did the Spill/Bypass result in a Fish Kill? O Yes I�JNo Location of the Snill/B�nrs; AyV►(_�* P*14 . .CAusc of IIIC Spill Ypry ill- c Rcp;tire 9ade; Atsa's Aja 4 ��C cl` �ic�u�:C+�tLcl�.Ptstuusssl��.ttc�r_ul; r_ Ae c_-4 C `3 i1 C 0(her Agencies Notified: Person RclxrttinR Spit 3Ypa��; ' Phone Numtxr: Y X9 —Z1 - 3yao ------------------------for)W(Use Unlv Date_--------- 9----� .-_— Ond Rcrort Taken bN.: Rcjsort Taken: Untc ' Tirttc DWQ Requested an Additional ll'nuctt Rcrx)rt: [O Yc% If 1'cs. %,hat Additional Inlurrrration is Ncedcd: 1-25-01; 5:14PM;Town of Spruce Pine ;8287658141 Town Of Spruce Pine 106 Highland Ave P 0 Box 189 Spruce Pine, NC 28777 Voice: 8287765-3000 Fax: 828-765-8141 .Facsimile Tr, -r., tai To.. Fax; (:::- �q5 Frarn: Date: 'Re: Pages: CC: .0 Urgent ❑ For Review 0 Please Comment E3 Please Re* 0 Pkam Ram ole m 1-26-01; S:14PM;Town of Spruce Pine ;8287658141 # 2/ 2 :Petmit[ee :N 'Incident Stared: Date �`PennirNumber:o���%a 3 County: � Time 0S- Incident Ended: Date I --2-5! 7% T� Source of Spill/Bypass (Check One): I e,, l f T on O Wastewater e o reatmcnt {Chcck'.One). hone V rnm Treatment O Second Treatment O Chlorination Onh Estimated Volume -of Spill/Bypass:Z� `T_ (A volume must be given even if it is a rough estimate Did the Spill/Bypass reach the Surface Waters? O Yes No If yes, please list the following: Volume Reaching Surface Waters: 0 Surface Water Name: Did the Spill/Bypass result in a .Fish Kill? O Yes No' n uc of the Sril1/B�nas, ?LA_ rrm p 54-v p p 0 -T-M r° Lam s ' , 1 4ze ��.C'/y • �• -�1,u1 Un Waste znd Rcntcdi ur tltc ctr..• �� ' ;1-�� '-�- r� BAN 2 6 2001 RK ''— oUAL,TY S? CTt 1_ I AS'diLL /lr(iL T rkrrUtiir rv_ 'rvrn[ uttr S REG1(iNAL ()FFI ; —� tL�.CsLlc �2� •Iat?i�tt fc� 7 t r.�.�ni111 at tlzt 1 � n� - -- _. Other Agencies Notified: Person Refxulin �' /l3� s�; / ,r� ��•_ phone Number: 1"ur i)1S'Q ---- -------------------_--------------- ------ Date_ --Z 1`�------- Use Oniv C1r�r1 Rejticm Taken by: Report Taken: Date Tinx I)N%'Q Requested an Addi(iornil 14'rittcn RcrK)rt: h Yes ONo" 'If Yes, what Additional Inforrnation is Necdcd: p_;i- 5-01; 6:5OPM;Town of Spruce Pine - ;8287658141 - t# i/ 2 Town of Spruce Pine ~` 106 Highland Ave P O Box 189 Spruce Pine, NC 28777 Voice: 828-765-3000 Fax: 828-765-8141 Fa��smle Transmittal To: %/�,� Fax: From: Data: Re' CC: ❑. Urgent O. For Review D Pam Cammarrt ❑ Pbws Reply ftycb Notes: J+ 1- 5-01 6:50PM;Town of Spruce Pine - ;8287658141. 7k 2/ 2 `--,� `. (i.,yl•771�'` }tcyi• :.LV3.Si:.:.x �:; az[c - : 2!:. �.:. ,h��� t, ewe S nt arv' S r Pumn rar_,nr� nd. WW'I' . Shill n g. i' (P! se Print or Type Use Attachments rf 'Needed.) ReO] t FQI� Peirnittee /[1r:U U i1�r l�l�itl�� ✓�ti�-Permit-Number. County 'Incident Started: Date O Time 1 Incident Ended: Date % — S�— v j -Time S Source.of Spill/Bypass (Check One) anrt Sewer O Pump Station O Wastewater Treatment Plant Level of Treatment (Chcck-.One): one O Primary Treatment O Secondary Treatment O Chlorination Onh Estimated Volume. -of Spill/Bypass: rda (A volume must be given even if it is a rough estimate Did the Spill/Bypass reach the Surface Waters? O Yes o If yes, please list the to Volume Reaching Surface Waters: 1P_11q- Surface Water Name: Did the Spill/Bypass t.-esult in a Fish Kill? O Yes NYC,No Local of the 51� 1t IIByRasti: / Ave ! lti Ll_ Ile Spill/f3]!pass: Duscribic 111C RclpairsMiidc; Ac i > i T rkcil to Ct nlairt_Soi il,-ctiledi'lle 01C Stir / Cy ,tea a zacliuc>`!`ltt� n ot• Pronoxr Jv_bt; Tuts 0 L JA N - 8 2001 Other Agencies Notified. rcrson Relxirlin S )ilt/lj �f,a«: rc_�za—n�IL =±21!��10_ phone Numbcr. Si�tn.Uttrr Date----- ------------- --------- -------- `---------------. ---_--�---.-U6e Un1r �- --- --------- --- -- Onal Rerc)l Taken by : . Report Tttkcn:. Unte Time 1)«'Q Requemed tin AdditiOIR11 %%*611cii Refxirt:.�C7 If I'm "A"hat Additional Information is Ncedcd: 10-19-00; 3=25PM;Town of Spruce Pine ;8287658141 # 1/ 2 Town of Spruce Pine 106 Highland Ave P O Box 189 Spruce Pine, NC 28777 Voice: 828-765-3000 Fax:828-765-8141 Facshfle Tr&ismi#A To: Z - l �/ �'2 /� �I� Fax: �a From: 1CA,4& e*q.?JjLC,7 Date: / " 00 Re.- -��IYLAP—oe ?2,— pages. CC: ' ❑ UJUNt /01--or Review ❑ please Comment ❑ Please Reply ❑ P%ase Recycle � �IOteS: r 10-19-00; 3:25PM;TOwn �t,"--<',pruce Pine ;8287658141 # 2/ 2 :.�•� ..: r�K�iti •� ice.=a�-1=r ��7. :trei uitee::' �tl d UU�1.�C ; tf =PetnurNtimber: QO lq.Z3 County- -`Incident Staried: Date _10 —lS DO Time92 L—kk D Incident Ended: Date /4=/ Time /-: 3U Source of SpillBypass (Check One): anit Sewer O Ptam�Station O Wastewater Treaiment Plant Level of Treatment (Cltcck .One): ONone O Prim Treatment 0SCcondaFyTreatmenj O Chlorination OnJx Estimated Volume of Spill/Bypass: (A volume must be given even if it is'a rough ectimatc Did the Spill/Bypass reach the Surface Waters? 1 10 Yes O No If yes, please list the following: Volume Reaching Surface Water: /1/6,tip_ Surface Water Name: Did the Spill/Bypass result in a Fish Kill? O Yes No Location of the SI i1J I/ L MAM Hwy �qf- A--� M���� �o��u,�, /J 1tv A y� �1� 4 1,, ev Action Taken ro Cijry,,tin Snit( _Ckj rt (ld Wtcstc and Itctitcdirdr the �Xe �, C),f,ui�tl Tti<:cn or Pt' sntt•�s�I�..t2c._Tttk OP - Other Agencies Notified: Person Rcfxmin I�' li3y �: a phone Number: _ �65— 5i�nalurc- a -- ------ ---------------=------ Date: S —d------------- ------------------------ For DWQ Use Only: ----------------------------- Ort! Rcpcirt Taken h%': Rcpart Tltken: Date Tin r MVQ Requested an Additiunaf Report: j0 Yca ONo.J If Yes. What Additional lnfotmation is Needed: • t 5-00 S_:58PM;ToWn of Spruce Pine ;8287858141 # t/ 2 NORTIL �a�AROLINA DEPARTMENT OF Town Of SprI11EMMIZONMENT AND NATURAL RESOURCES 'kd = � 106 Highland Ave DIVISION OF WATER QUALITY P O Box 189 Spruce Pine, NC 28777 ASHEVILLE REGIONAL OFFICE Voice: 828-765-3000 NCDEtt r Fax: 828-765-8141 ti Facshiffle r"nfiff.#.l JAMES B HUNT- 4 U . To: ��, 2 Fax: say^ a 6AYNE McDEV17'f¢ '- SECRETARY prom: � � mace: 4 Go t( F 6 � RR T. S'i'EVEN�iS�y q, RECTOR C y6 4y�t a �_ �F1,NC dJ � T 1? (n I Pages: ❑ For Review CJ Please Comment ❑ Please Reply ❑ PFease ReWde D p�� BAN 5 2000 As WA SECTION REGIONAL OFFICE INTERCHANGE BUILDING, 59 WOODFI.N PLACE, ASHEVILLE, NC 28801-2414 PHONE 828-251-6208 FAX 828-251-6452 AN EQUAL OPPORTUNITY / AFFIRMATIVE ACTION EMPLOYER - SO% RECYCLED/10% POST -CONSUMER PAPER 1- 5-00; 6:58PM;Town of Spruce Pi�n�e'S/�'/J i'afv`Sewer Pu n Stti� ;8287658141 # 2/ 2 NORTL, :AROLINA DEPARTMENT OF- ENVIRQ;NMENT.AND. NA URA�_,RE.SOURGES lsrbra:+orn T. ' QUALITY . .., ,jsmrnr, cr__ •., MiHEVILLE REd.IONAL OFFICE (Please Print or Type - Use Attachments if . Needed.) li1C. DM Dt.il.`?�J C PermitNtimber: Dp f a County: Int:rde taxied: Date ~CCU Time Incident Ended: Date --s-00 Time l(o; to -- o Source of SpillBypass (Check One):Wanilarysewer O Pum Station JAMES B.'HUNTJ11" , O Wastewater Treatment Plant 'a. !If OR L.e'vel�of Treatment (ChccCc-_One): None O Prim Treatment O Second Treatment O Chlorination Onit ��`..� �,� ..nth I :Estiniate`d Volume -of S n11B ass: - ' i yP' L 00-SQd�4S (A volume must be given even if it is a rough estimate -� Did ttie Spill/Bypass reach the Surface Waters? Ycs O No If yes, please list the following: ,a' tig tie? Volume Reaching Surface Waters: JVAYNE MCDEVITT IgdQ _ rj'�O q/) 1,1, ame: Surface Water N N 3ECRIET! R- d-1he;SprlUBypass result in a.Fish Kill? O Yes No cx ovation'` of the Spi1wDyp- Sti Ni-! 0 .- 1 ` CERR T.S I �Qfih Spill !ni�ti�' �IRECTOR" -C . af> DVc� ldvu(� tf ekenait:s h4ach- hj1Za - fro (40 w N u o tLt ©�' PL t VVt,p s I E_ s l-1-6 o Ij q4-,,c ojt L Iti - 700— 4 t o s'2 , _ 1 eF- A G% Dom. A Q �:Qmher_-A` cnrte,. N, o ified: I. nll----------------------- 0iIL 5 +4 -61,Otik 11 I g,A1�zZAA C4f-ts;rv7" Phone Number: 96 S 4 0©C) Date: / ` — QO +._ = Mtn►J,1 1>ttrCCn n]': RCpoti Taken: Date Time "46A4JQ Reyucstcd gn Additional Writicn Rcfx)r7: l� fjC� , H GE BUILDING, 59 WOODFIN PLACE, ASHEVILLE, NC 28801-2414 l - j( PHONE 828-251-6208 FAX 828-251-6452 +` C � ^ ftaLAdditlpnal Inlc%tltlapl�(ilr�a�1{ipQUli�'fUNITY / AFFIRMATIVE ACTION EMPLOYER - SO% RECYCLED/1 O% POST -CONSUMER PAPER y 1! �anitary Sewer Pump Station And.WWTP SpiI1 or Bypass Report Form '> / (Pleas�j Print or. Type -Use Attachments, if Needed ) Peimittee: d r d (l � 7�zym AlW Perm i' - f n Number: �O,-)zVIL- County: ISF :'-Incident Stacie& Date o? -6 ' Time - i &--0 47. Incident Ended: Date Aa 6 - Y9 Time Source of Spill/Bypass (Check One): JV Sanitary Sewer O Pump Station O Wastewater Treatment Plant Level of Treatment (Check -One): None O Prirn Treatmdnt O Seco ndary Treatment O Chlorination Only Estimated Volume. of Shill/Bypass: 629e - �� �A (A volume must be given even if it is.a rough estimate Did the Spill/Bypass reach the Surface Waters? Yes O No If yes, please list (he following: Volume Reaching Surface Waters: gyp_ ypo /5 Surface Water Name: Did the Spill/Bypass result in a Fish Kill? 10 Yes No Location of (he Spill(B)"ass-/-Z Cause of flit Spill�/I Urtss: hrscri�ic flit Rrnitirs Ma ic' "q �i Lt7/;411 Action Taken to Coniiiii Still,-CkAul )D W Iti(C Ll d RClltc dl I(C the site; CAA: Ajiolt T'Lkcn ot'PI'�11(1,���(�� Gr._,C�tEiC.tt (� I'Irl'cIl(I'u(��.t� SI?Illti n( 1 is I nrntinn O(her Agencies Nodf ied: Person Rercming S ill/Ijypr : 16r iAl- ��1 LAIE Phone Number: Si n_afttrc _ _ Date: _/a 7— ff I)«'Q Ut;c Only: --------- -----------=-------------------------------------------------------------------------------- I Report Taken by: Rcfxitt Taken: Date DWQ Requested an Additional «'t-Men Rcfxrrt: (o Yes 0 N' If Yes, What Additional Infiurrta(ion is Needed: 12, 9-99;11:5OAM;Town of Spruce Pine ;8287658141 7F 7/ 2 i Town of Spruce Pine 106 Highland Ave P 0 Box 189 Spruce Pine, NC 28777 Voice: 828-765 3000 Fax: 828-765-8141 Facsimile TrmsmftW TO: Fm Yax-9-S/ - 4y-S"_2_ Re: J1ec2 , /% Pages: CC: ❑ urgent ❑ For Revifty C] Pkmse Cwn"ent ❑tie Rep* ❑ Pkm Reryeie PIE �I 12-, 9-99: 11:50AM;TOWri of Spruce P1ne ;8287658141 ?f 2/ 2 rv..�. f: - .. ��•. starjo ass (Picts Print ar Type : Use Attachments if Needed ) x�' f� Permit�T[[b Inciden t Stalled: Date J a - 6 Tune � aq - Incident Ended: Date Time - Sounce otSpillfBypa.�s (Check One): Sanit Sewer O Punt Station O Was[ewaiiir Treatment Plant Level of Treatmeni (Check- One): �ne O nmaiy Treatment O Sewn Treatment O Chlorinatio p Estimated Volume -or SpW/Bypass: ^ pat� (A volume must be given even if it is a rough estimate Did the Spill/Bypass reach the Surface Waters? 21yes O No� If yes. please list the following: Volume Reaching Surface WaterN. gyp_ 0 4% surface Water Name: Did the SpilUBypa.%N rrsult in a Fish Kilt? O Yet No , 14H4 PA5S a,s ofth SPiil{j},Luti APP 40- A`i23 +47 A tL Ar fl-,rz e- ? /l a 1V 'tom 4a3 aq . rC t ► � de-e'q of +%Cy Ji n /� ivv sip � �' ��P� M tile: %Acted D.4 xn,4 13 LrAF /J ►�� b.�s tlt�iun T '�n_s�' Psi' ,u�►�n� tt}Jtc_Tuk ' Otlwr Agencies Notified: Prr.oa Rclmrting : ltf��/lA:��J �.1r✓ ` Phunc Number: 1pdr- WWIDwe Af Rerwri Taken: Date DWQ Rc<quesled an Addkiom;d Written Rerctrt: jQ %s 0 Nei 1 If Yes. What Additional Inf0fulation is Needed: 01-di Report Taken by: T-Q39 P-001 e,. ToWnt of 5praotiPjae + Alm Box 199 KC 28M - - � 106�A•� (0*765-30DD Voim Trpo: Fax: tC .� l fa F mm: a �Farl�view ❑ FbmeGonunmA ❑ PbawHaply a F r JUL 06 199 07:22 r, . j fN-A L/j 44 st-, 8COO l - n �:, •� a i JUL - 61999 n; L11 �UAU I Y SECTION T-C39 P-002 JUL 06 199 07:23 itz' ,,, ,.+ •,y :.•' " is : - ` � +t A. �,• ,.__ a�'Y Sewer P3'tfion an+d 'UV'r`h iI1 cir 7� • '' •._ :.: (PlencPrint seA piss Rio � Use �Gf111tG11rS if NEe(i�•) 'S-R[utt ii.N . - ul21bCI: cotlzity: ; ktfd6t Started: Mic Z 1-2l _ Time . na hncidmt Faded: baw I Source ofSPHYBypass (Check One). ana Sewcr Q um Station r am_ C) a5tewater Treatment Plant LeVe1 ofTreatrnet)t (('ltccfC•.One): O None Treatcxicnt Q Sewn Trea I~etimated Voiurrte•c�f S i1I/B ��[ O Chlorination Ort1� P ypass: ep (A volume must be given even if it is,a YOU estimak Did the S•pi)VBypass r;arh the Surface Waters? yes O No 7f yes, pleaxe list the gh following:Volume Reaching Surfacc Waters_ Surface Water Name: Did the SPHYBYPISS wsuit in a Fish Kill? p I' p o k "04, MID i ( 9 . u +f�tiltilZ 7'akcn nr Prc� c��! 1���,C_�;1� Othcr Agencic.% Natifted: Pcrrpit RC Spi 9 L Phone Number: . �E-- oo ,aa Si�n:rtu;r For DIVQ Vw Only: __ .------_- ------------ - -------------------_- MDxC----.----------------------- Oral RcIvrt Takcn by - �--.. ltcun Taken: Date Time DII'Q Rcqucsted an Addi(i mial Wrillen ltt l7ctirt: (Ci j'cc (INE) c) lF t es, What AdditivnW Information 4 Need: JUL — G 1999 7-27-99; 9:32AAA;TuwrI of Suruce Pine ;8287658141 It 1/ 2 To, Mike PCX_r-%e_ev- Elbe. v-4, Fls:.Oo.k Ave. Sp►11 CC: Town of Spruce Pinc, P.O. Box 399 106 Fgghlmd Av=c Spruce Pine, NC 28777 (828)765-3000 Voice (82a)765-8141 Fax Fax: Jgag) Q 51 - 1,,14SZO Date: -7- -a-7— Pages: a Urgent ❑ For Review ❑ Please comment 0 please Reply, ❑ Please Recycle 7�-27-99; 9:32AM;Towri of Suruce Pille ;8287658141 2 41 Me Sk Sa—MOL&W (Please Print or I)Te Use Attachments jrNeeded I ux�-. Pemli"Ndjhber 00 �/- County: Incident Sta11cd-Date Time I'00 P" Incident Finded. Date 7�2-4 - 7V Source orSpill/Bypass (Check One): gs�anzf������ Sewer 0 Pump Station 0 jg-ew��IeTTre�ajmenj �pjanl Level of Treatment Whctiil.one.): - ------------ one 0 rfmaryTreatmeni 0 econ T n (A Volume must be given even if it is, a rough evimat, Did ffie'SpillMypass reach the Surface Wafers? 9 es !O No I If Yes, Please ]is[ [he following: Volume Reaching Surface Waters: $'o %3 - J'3"c;0-TA Surface Water Name. - Did tile SPi]YBYpa.,;.v result in a Fish Kill? 10 Ye..; -&--N-0-? L-011fign Of the Sj2iIVBj#p9Sq Action Taken to C(ti, . I 2ULQSUUL-L�p WI RdL41-JINIC 901L" -P-901t- A-5- etb�� Itb 01her Agencies Notified: Pcn-vnRe min SpijI/BV;j, pe c`ir Phonc Number: 2-8- 74 5 - ;3 a o --- - ---------------------------------- ------- - - ------- - -------------- Date: 7 For MYQ Use ()01)-: ---------------- -- ----------- ------------------- Oral Rerx)n Talton I bv' R . eporl Taken: Date I)WQ RrquLmjed an Addi(iml-11 Written Report: 0 N(Ij If Yes, What Additional Infunnalion is Needed., 'r—'�74 P-001 APR 22 199 08 a 29 Pniri�e ;��. _A�_ ._ - �earnii�riiiti;...��: -- f � �, . • - .:h 1 sie it Siaiied: bate 4-2Q,�9 'Xnm.. Ig Inci runty: -1 ( darttEndecl: Date �f-- ��" Sattroe of SpilUByp:ms (Check One):i'laxy ewer O pump Station astewater TreatmeRc �p_i�t ��.... _ _ Levcl of �'rratrisent (t4lrccli.Onej: O None „mart' Tn_eatrne [ O Seooadary Treatment O C .1irca lion Onl` EStimaled Volume of SpellfByp s_ 4S-O - , (A. -volume must be given oven Kit is*a rosrgh e`iima[c Did the SpilUBypa cs whaeh the Surface waters? Xes O Na If yess please fist fhe following: Volume Reaching Surface Waters: S`e - A I Surfane W21er Name: I d!`, ~` Did thsr Spill/Bypatis rowlt in a ash Kiil? 10 Yes cr �ivn of the S�l�ynas�- , f''" ,t 130 r, a T& it .q fa; ran F%$ U i° S R'44. � e'W'.7 tom. "her AgencicF Npuricd: PWne Number: _, - Fot• �)lt°� Use OnIT.`------------------------------------------------------------- D�uc__` ` ? :_____ ()r:xl Report Takers by: Repart Taker,: Date �� 7'irtsc DK'Q Requested an Additional Wriaen Relxsft: It Ye-s. What Additional fnfottiraticin is Ne4 de : T-7S2 P-001 APR 12 199 11:46 ,ff.�i: •. •%' si ,:: _, ,,5., _ :tip ,;.p •• t M., ,+x: ):t�.i.. • 41 ItarySewer 'uMp S a�ioxi anti 'l'P S�' yr By as'Tt powF (P[easa t?rinI or Tyfie - Ujw ,PAlubchanents if Nead `�'i s�•;�: Permtit#�: • ��iaatLi�r� � � ,!� � F.exttiitNtitu�t-+�ic*r e ct -) .'• : • � . ' • - F• 'Incident Staited: Date `It— — p .. Time -- -- - Incident F-nded Date I -le f_- : Source -of Spill/Bypass (Check One): WSanitar y Sewer O nrgp Station' a astewaterTreatment Plant Level or Treatment (Check•_One)_ 10 None mary Tr�tmeut Q Secondary 7rea[men[ O orinatrort Oni, Estimated Va7lutr>es. of SpiIllBypasS: °O -loa oIA•_ W (A volume must be given even if it is*a rough eatimatc Did the'SpillfBypass reach the Surface Waters? o Q Yes Uyes, please HIS! tile following: Volume Reaching Surface Water.; Surface Water Name: Did the Spill/Bypass result in a.Fish Kill? 10 Yas No L.4cit[i4AS?1' the S fll/By • ss: AvpA iiU ,`.vi/-d4h- cause of th nilllriv[ty 100M CMMWM�5 j H 5 i s pId- k I: H `i— hol 14a4 r r! �`@•4s7 J. x^ v L /" J/J!� ci.R'- liA'l'd v, f 6 1lslit�n'I'�cn orProtxnc 11t�1.t;�1;'�" t� � � � D nn APR 1 31999 ER ASyf6'LRC'jAC�TySrCTIOC cr Agrneics Notificd: .'» GIQ�AL OFF C%tltF i'crk�n lZcpc�tiiag 5pi!llBtipc�«: a e Phonr Nutnber:ci`.-.d.5 s 4a turr For )i WQ -. --------------------- - Dme:- Qr<il Rcpcw[ Taktn ht': Report Taken, Dgtc Tinlc I)%N'Q Rrquested an Addit MIA S 611cn Rer'XIrt: If Yes, %Vhat Additional intcutttation is Nei-(W-. r4�mvaaseei �_ T*- From Date- -AUM02f, RW- El Uvo mcpl.� Ll P'khlse commmt 0 PNNWBRMW PbmeRocydia 2G. , oq ,�/ � 7 /0 : S Z 4. -y.,, L dVv/LL �-j 0 yv T-�1 P-001 JUN 10 198 09:40 S_ nituy-Sorer, Pump S-Mbim and.Mn&-"iP. Spa ar $,ypass �2epo Form (Phase Print or T� - Ilse Attachments if Needed j Peri itttre; ___j3_ad4C T: e_ -- -- Pertnit-Ntiinber: t00-214 3 County: Aw 44� Incident Started: Date zM 'Tirne ' _ YMCA M 1136id6ntEnded: Date we Time Source of SpilyBypa-s (Check One): anitar Sewer p p Statiori () Wastewater Treatment Plant _ Level of Treatment ((7heck One): 10 None O P�Treatment O NEo_ndary I D C95rination OniN Estimated Volume -of Spill/Bypass: (A volme must be given even if it is'a rough estimatr Did the SpiIVBypass mach the Surface Waters? Yes 0NQ1 if yes, please list file following: Volume Reaching Surface Waters: 16.0:C,41 Surface Water Name;_�J Did the SpiMypass result in a.Fsh Kill? 10 W.! d into l&ation of the SpiIUB ass: AO cd 4}} '��p1-r�%�i�I�- i4ilA {Ta,HL'C• p +'[ nr MoM.-MMM&M Af ioTIA -ca o mIW11 �Di1l. 1C Ott p W. fLtC'illd nlr li ialC tlIC SIIC: Ar�i111 Takcn orf*rt c�L r� lt.k�..�.1kst1 t{z �' ,„Yt'►k ' ittJ���.tlt_lilis Lnration• ractc•e �.aR rl w 1 �. p`+ �- P-1a-,.x�t�; A flple��lav �- �•c ST •�:.� �ai�: p,�{--�, .Arc L-�' �� ; ..-E�-'�. -�U � use -� Outer Agencies Notified: person Reputing Sp IVU ---------------------------- Oral Report Taken by: DA'Q 119ocsted an Additional Wtitten Report, If Yes. What Additional Infutrrtation is Needed: Phonti Number: Date: ___4 -_ Rcpvrt Tttken: bate — Time ct.dtl(i5t•hc• Rj•F"`Fj*ns Fi.tm RM7 86610 1 NM 7--- rn, LQ -r--1-77 P-001 MAY 15 198 11:52 -' , aril Sewer Junta 5tarttnn arty •'1?!f 11 or Bypass Ise (P1nsePAn(..prTy& if Needed-) -Jitcbell. .621423' ePi�r_V16, * ", A53. county. P Ar 115/96 1:00 Cicident staAC& Dale Incident Ended: Date 5 Sn=eof SoilyBypas,.; (Check One): Rb.Samitary Sewer O��Vtation 0W&s(vw9li;TMtmen1PJant Level of Treatment (alod-one): 10—Nonr 0 PrimaryTreatment 0 Set on!Lag Treatment 0 Chloritia--tionOnli -Estimted Volume: -of SOMMM' 1,500 al.. (A volume must be given even if it i-;:a' rough estimate Did the Spillfflypass reach the Surface Waters? P9'Yes 0 No If yc,.q, please fist the following: Volume Reaching Surface Waters. - - unkrKxm Surface Water Name: Beaver Cl-eak Did the Spill/Bypass MIMI( in a Fish Kill? 10 Yes e-No Beaver Qo[ Causc of Lim Biockage resulting in overf�xw bium isolated manhole Past-W Fax Note M1 DaW5- I =-�ga I P.#a--Qfm 0- ;?— "Mice jhy-Ker 'Vdx-r+ Wwman FTM;O*# MIN 0 Fax#- IF— # C1eaDed up dritsr aMl-icatiM of I ime MON Wlus if t. 1(a U74T51n, 9 Q I i PT k-it"I F M9 TME if &.*— go%.. 9 3 0 U. E - - W �—V-1 M I �1212 A "her Agcncic% NeAffied: 90m Perm Re" SP%Il1Hm.%.%:RM� C. wioolm Phone Number: (11211) 765-3000 Dole. 05/15/98 I ------------- — ---- — ------------- — -- — -- — ------- — - ------------- For VWQ Um Only: Oral 11cpQr(Takca hp: 1)'A"QRcquc.%tedanAd(iiiikiii.dtl'si(tcnkc[Kiri:.f -Yes If Yes, What Additional Information is NeMed: Repart Taken.- Date lime j t 17??7 P-002 MAY 15 198 11:53 * Spill reporbe3 by unknown fisherman - Do not know exDztly when spill began. Volum appeared to vary from 0_GPM to 15-20 GPI. �1 T--5 P-001 MAY 14 199 07:46 . •.tip ui anitary Sewor,Pumn Station and VV'W TP Spejl car Bypass R=QXI EQ (PicnePrhuurTYa.-Use AvaamcetsifN&&d Pt utnee= .,, •� e. ?t w- f PeK * Nambcr_ -0:2 1925 County: r imidetitSmcd_ Date _S r Tithe 1 f :30_.__. jmi&=Fttded: Dm T= Seume of5pMypam (Clink Ove): IoSau LtjjSewer opumpStudm O W=tewater Tream3M Plant Level of Treatment (Cheek Qne): IWAmm O Treatment 0 Smanday Trutuent p 'on Estimatrd Volume of SPHYFyPRs_ (A, valttme must be glum eves if it s a Hough estimaae Did Ow SpMMypass reaeh. tho Surface WUWM? G es , o ' If yes, please list &a foliowwg; Volumm Rmhmg Surface Wamm. Surfw* Water Name: Did dae SpHIMYpass result in a Fish MI? es 0 NO u ot= e S ' — •---• — mold Av'emy-c—, • S..'4 �i N T. .the Bodo Madre I me '4 Post it° F�c Note 7671 ��� CbMDPt Lb �1O^e Phone ih FEp(!F Pat* it:! . Action TAM to rnnwLWL Clean ug Vifu teyRamectim the Sine: 1 (�tve�g�e.�. �i���`!c_ A/�o�t v► � as14�7'4e �,Jq.�.r/¢. o+� �qv�'�t-�.s T A►4 gv.n�n:'f Action lak=r Pro e+d to tie Ta � ut,�r�Ye�[ t l~tzt nil at this Location_ 19e.lfe-" :S •Ga-�'� co.rzf .� :.�.� �s�,�js c ys.�� bfe�.ka�►�e. 64&4 [ W.!/ A, Z�AOAlc frs�,siera Otis A,ge ades Natified:,-- Persoa Rm=tW2 5gill YAass= , -64 ex rc}is+c•�,r r-+-� Phaua i�aber: Far DWQ Use Only: Oral R"d Take by: Report Takeo: Date DWQ Regttmmd au AMtivual Wntten Repow 10 Yes. if' da, What Aid doial fnfott wAbn is Necded: 'PMm = PAimling Faun 8197 FROM : AAET SPRUCE PINE PHONE NO. Feb. 18 1998 iO:OSAM P1 merictnngfiam. .spruce :pine Water -treatment :pfant FAX COVER SHEET TO: -PROM: R-P- L<eJ- f XPQ COMPANY: VATF: FAX NUMBER' TOTAL NO. OF PAGES INCLUDINC COVER, DtIRGENT DI'LEASECOMMli"T 011J.12ASHRIQLY D NOT'LS/C.0MMENTS: 200 Clearwater Road, Sprucc Pinc, NC 28777 Telephorte (704)76254606 Fax (704)765-1949 f, L FEB 18 1998 FROM : AAET SPRUCE PINE PHONE NO. Feb. 1B 1998 19:©GAM P2 i In VV {please print or 7}ge - Use Altachtments.if Nc dcd ) Petrn9ttee: %�%'-''� ice &,j e- l"�`-10 Perrnit•Number: f �� 1 3 County: Incident Started: Date 2 W' i 7 -j'S +°^- Incident Ended: Date 2-17"M Time Source of SpiII/Bypatis (Check Onc): Q Sanit SeH'Or O Level of Treatment (Check Cane): O Nonc BF Primes Treat aslcwater •I1catment B-stimated Volume of Spill/Bypass: d60- _ (A volume must be given even Wit is a rough estimatt Did the Spi"ypass reach the Surface Waters? w Ye's O I�� If yes, please list the followaag: Volume Reaching Surface Waters_ Surface Water Name: /[9o+2T� 70 >��.y Did the Spill/Bypass resull in a Fish Kill? Qn Yes . Nn C�`Ye�Y t---, �ti�t�rA�.1 � t�+] Q2Jr.� { stoc (0� CauK T4 {�(�-t.- t'�-`�6s •. e� {. � p� � S t+.}�C. �ilvl�l �Vtl� Q1� M�`i����•- 1"L�_i gdr����lQf-I-L%_Y4P_ Cjk IT ,'r` to he�� rM ,�e.� lam► mat r �ry r Q„{5a . FAA-. K y�-k�.•�,.ic.+.r� r�.�aQ /"t f6�.t�' �r2ic�-�rc..3-� F''I���e.5�5� A�ba�'2.D4 t,J� ��•,�'t'" ►'`sauJ,rV l�^e. R{� l r� �- �� ��St...otl—C'� Pf�b��..�..�5, . >4ll 'e p.. t� y� i i? 7'o Cr�nZ`a:aJ 7rz 5�ti1 i3y GF,Gx,_��c� oc.K� 1e ' � • �tk� Tilkr.� � Prry nl �' tt � • �ls at �i�L��f.tttlQn: ' 7&-) S.�,, 2 f t U 7� Ye. f f� ?� iyU S 10 Q � ---- Other Agencies Notified: - _-- ------___--- Person R )rl' S /Bypjs%- phone Numher: tSim -------------------------------------------- i------_--------� For IM Q Use Oral Repon Taken by; Repw Takcn: Bate Time DIVQ Requested an Addhionttl Miltrn Rcl'xw, Ki Yes 0IQ c]�---�- If Yes, What Additional Information is Nctded: R� FEBl I v--.trrt�. -.. u_......-_ \ 'v TIER toilAL ®FFiC1= -, ASIM FROM : AAET SPRUCE PINE PHONE NO. Jan. 08 1998 01=16PM P1 r AmericanAngfian -en.viron.mentaf-ter Fjnoi'ogie!5 Spruce Pine 'water 'treatment 19fant FAX COVER SHEET TO: /1/j L ke- PAg 14 FROM: COMPANY: DATE. - FAX NUMBER: T07AL NO. OF PAG S INCLUDING COVER: RE: ❑ UR.cY.N•P ❑ Fop. Rt; pm ❑ PLILASB COMMENT ❑ PLEASE. REPLY ❑ PLEASE RECYCLE? 200 Clearwater Road, Spruce Pine, NC 28777 'Telephone (704)765-1606 Pax (704)765-1949 0 d'- FROM AAET SPRUCE PINE PHONE NO. Jan. 08 098 01:IePM P2 A Sanitary Sewer. Punip Stgoon and Vr*W S Revarl Farm (Please Print or Type - Use Attachments if Nee& ) e- PCrtnittee- -Vo4'jn- Pernift-NumberiVe- z)oziyz CQ( 3 county: AL Incident Started: Date Tj= dg-:2y Incident Badc& Date Time Source of Spill/Bypa&,; (Check One): )0 Sanitary Sewer OPUmp Station j� Wastewater Treatment seat i-&vcl of Treatment (Check One): 10 None XPrimary Treatment OSec Treatment (0) ChIlod tion 6F. Tzemyne Estimated Volume of SpilllBypass; • RA- (A volume must be given even if it i,, a rough estimal Did the Spill/Bypatis mach the Surface Witters? If yes, please list the following: Volume Reaching Surface Waters: AS pg6t�,e Surface Water Name: &kT(, -r, R, Did the Spillffiyp&%s result in a Fish Kill? 10 Yes 0 Location ofthe SWULDyWim La-3,-J —113 OX A JtiKA--- r4&^,- le Describe flic Rcmda Madco 7" o,4 1/0-3 T4> LLe- 7-4 45)LjAe 6"qaj;t% As3bin Tab-cf, to 01010W 5WILOM IIj2 Witste 411d Howdiale the Site: I ,Ixtion Tuke-tur Other Agencies Nodficd:Ake, Akwzee- &--Owoft 9.,,#&/ Pcrurn R mitt Sp HIM AN Phone. Number, 2DY - 74,E7— -3w7 srnatu Date: ---------------- x ------------- For D Oral RerKirt Takcn by: Report Takcn: Date .1. 1 . 311C D"'Q Requested an Additional Writica Report: If Yes. What Additional Ink-wination is Needed: ------ it M n, v Inrl48, %x m5 1� !Dz1 pA^ ;;oo , f oQ-�� eta C �l{ Mo�k CL0 4s 10 h61 ve; C;L Loq6k C�077 Tka ate,. I y AI -0!5 We- (2f3L>(JQ 1�0 1 S f � t�w� ~�� � c . ��� � �E•�cz� �� � is �1 A-�..cD T6 ..�- w� �( ! � fie.TA c�5 f vim. ck s`~� `'py- ✓ONT �sF:q9�,7,, £d Wd8T:TO 866T 80 'uer : '❑N 3N❑Hd BNId FionNds i-3UU : 'WOZW . ../"AAA•'"A T AJV .. VA. A "ally../ 6J 1."LA VAA "I A\A .. 'TV A A 1..7JZAAAy1 jJ Y�QJJ 15,GPU11 1-'VI-In (Please Print or Type - Use Attachments if Needed ) Permittee: '/&,-)et of Kj e Perrait-Number: MC 00aI c/-92 County: � ►T �e Incident Started: Date 12- ig"-1Time 3.' ISM o fn Incident Ended_ : Date jot-/"i -p 7 Time F!ed A.,-, Source of Spill/Bypass (Check One): Sanitary Sewer O Pump Station O Wastewater Treatment Plan Level of Treatment (Check One): JR None O PrimaryTreatment O Secondary Treatment O Chlorination Only Estimated Volume of Spill/Bypass: I D (A volume must be given even if it is'a rough estimate Did the Spill/Bypass reach the Surface Waters? 10 Yes -No If yes, please list the following: Volume Reaching Surface Waters: ��� Surface Water Name: Did the Spill/Bypass result in a Fish Kill? 10 Yes - No ] Vocation of the Sj)J N, ass: �e'Je k l- < <v e C v n 6 i 2� r� i cr-� a � u u-e- P 20 ZS(=Er Cause of the Spill/BU ass: Tke C_p,.� 2flTAT r�t��e-Idie�-. e<M�2 �e�u� Ova 0-?, 0S�CjAe !VC. wc,`-a PU PIVP r L-n� FRar-L kole l T- e- 67 L e-/4 (3,--) (1 1 keKe 1w5 e hcJ Describe tltc Repairs Made: ((�� Rb��A ( t-J ti Se Zvi A-h -.1-'J-Coe'wtej Iit�fi��ll Other Agencies Notified: T�161 2 and Rcmc fiatc thc Site 1 I r, tet l-- Person xc�' 1113w ss: _2-�/PP�/ � 1�U ri Phone Number: 76 Y Si natuJ- _ Q j ----------------------------------- ------ Date: / curUly. -�- -------------------------------------------------------------------•-- ral Report Taken by: Report Taken: Date Tillie DWQ Requested an Additional Written Report: (O des ONo,-j If Yes, WhayAdditional Information is Needed: I Sr'111/H\11Ali. k[•f..rH uu• t:-"' RN7