Loading...
HomeMy WebLinkAboutSWA000083_3171999SDV_R1_20201221PARCEL DATA:OWNER:DUKE POWER COMPANYTAX DEPT - PB05BPO BOX 1244CHARLOTTE NC 28201-1244PHONE: 704-382-4021PIN NUMBER:9642187974TAX MAP NUMBER:9642187974TOTAL AREA:35.01PARCEL ZONING:MR-LIDEED BOOKDB 3281 PG 488PLAT BOOKPB 2018 SLIDE 11535911 ADDRESS95 WONDER WAYMILLS RIVER, NC 28759SITE DATA:BROADPOINTE DR,MILLS RIVER, NC 28759TOTAL PARCEL AREA:35.01 ACRESTOTAL PROJECT SITE AREA:9.94 ACRESTOTAL DISTURBED AREA:21.85 ACRESPARCEL ZONING:MR-LIEXISTING IMPERVIOUS AREA:0 SFPROPOSED IMPERVIOUS AREA:101,491 SF (2.33 AC)PROPOSED BUA PERCENTAGE:23.44%*NOTE: BASED ON TOTAL PROJECT SITE AREARIVER BASIN:FRENCH BROAD RIVERREV:THIS DRAWING ORBILL OF MATERIAL ISCONFIDENTIALAND MAY NOT BELOANED, REPRODUCEDOR COPIED, EITHERWHOLLY OR IN PART,OR MADE PUBLIC INANY MANNER WITHOUTTHE WRITTENCONSENTOF DUKE ENERGYCORPORATION.Contract:AS BUILTPRELIMINARYTITLE:LOCATION:SHEET SIZE:REGION:REV:DRAWING NUMBER:SEAL:Phone:Company:Date:CITY:COUNTY:STATE:STATION NUMBER:FILE NAME: 3171999SDVD:GFUSION FILE NAME:15574NC-SCNCFERNCLIFF RETHENDERSONMILLS RIVER5574COVER SHEET115 KV SUBSTATIONSITE DEVELOPMENTARCH D 1 SDVFERNCLIFF RETAILBROADPOINTE DR,MILLS RIVER, NCSHEET SCHEDULE:3171999SDV3171999SDV01COVER SHEET3171999SDV02SITUATION SURVEY3171999SDV03OVERALL SITE PLAN3171999SDV04SITE PLAN3171999SDV05SITE TURNING MOVEMENT PLAN3171999SDV06SIGHT DISTANCE PLAN3171999ERC3171999ERC01OVERALL EROSION CONTROL PLAN - PHASE 13171999ERC02EROSION CONTROL PLAN - PHASE 1 PLAN A3171999ERC03EROSION CONTROL PLAN - PHASE 1 PLAN A3171999ERC04OVERALL EROSION CONTROL PLAN - PHASE 23171999ERC05EROSION CONTROL PLAN - PHASE 2 PLAN A3171999ERC06EROSION CONTROL PLAN - PHASE 2 PLAN A3171999ERC07EROSION CONTROL DETAILS 13171999ERC08EROSION CONTROL DETAILS 23171999ERC09EROSION CONTROL DETAILS 33171999ERC10NCG01 EROSION CONTROL NOTES3171999GRA3171999GRA01OVERALL GRADING PLAN3171999GRA02ACCESS ROAD PLAN AND PROFILE3171999GRA03PROFILE OF STORM DRAINAGE SYSTEM3171999GRA04SITE AND DRAINAGE DETAILS3171999DRG3171999DRG01SOILS MAP3171999DRG02FEMA MAP3171999DRG03USGS MAP3171999SPC3171999SPC01SPCC OVERVIEW3171999SPC02SPCC FACILITY DIAGRAM3171999SPC03SPCC DETAILSSURVEY:ALTA PREPARED BY:MCABEE & ASSOCIATES, P.A.3 MCABEE TRAILFAIRVIEW, NC 28730282-628-1294SITUATION SURVEY PREPARED BY:MASER CONSULTING P.A.5275 PARKWAY PLAZA BLVD.SUITE 100CHARLOTTE, NC 28217980-245-3161VICINITY MAPSCALE: NTS3171999SDV01EROSION CONTROL:CONTACT PERSON RESPONSIBLE FOR EROSION CONTROLAND MEASURES MAINTENANCE IS RYAN KORMANIK.PHONE (864) 387-9611PROPERTY MAPSCALE: 1" = 200'3171999SDV01ENGINEER'S INFORMATION:COMPANY:DUKE ENERGY CAROLINAS, LLCCONTACT:JOSHUA A. PEELER, PEADDRESS LINE 1:526 S CHURCH STADDRESS LINE 2:CHARLOTTE, NC 28202EMAIL:JOSHUA.PEELER@DUKE-ENERGY.COMPHONE:980-373-8514NOTE:CONTRACTOR TO FIELD VERIFY AND CONFIRM LOCATION, DEPTH AND MATERIAL OF EXISTING UTILITIESAS WELL AS THE UNDERGROUND ELECTRICAL AND EXISTING GROUNDING GRID PRIOR TO STORMDRAINAGE INSTALLATION. COORDINATE WITH CONSTRUCTION OVERSIGHT FOR INSTALLATION. IT ISTHE CONTRACTORS RESPONSIBILITY TO PROTECT UTILITIES DURING ALL CONSTRUCTION ACTIVITIES.ANY DAMAGE WILL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.ESTIMATED BILL OF MATERIALSMATERIAL DESCRIPTIONQUANTITYUNITSILT FENCE7,668LFSILT FENCE ROCK OUTLET36EACOIR MESH BAFFLES779LF12" SLOPE DRAINS240LFROCK CHECK DAMS8EACONSTRUCTION ENTRANCESURGE STONE 6" THICK19,151SF15" HDPE TEMP PIPE52LF15" CL IV RCP CULVERT PIPE80LFHEADWALLS0EAENDWALLS0EA18" FLARED END SECTION1EA12" HDPE N-12100LF15" HDPE N-12114LF18" HDPE N-12159LF16" DIP - FLANGED 1 SIDE22LFRIP-RAP APRON (CLASS 1)193SFABC CRUSHER RUN AVG. 12"THICK7,203SF#57 GRAVEL 6" THICK86,289SFMATTING ERONET57,692SFORANGE PROTECTIONFENCE405LFAPPROX. CUT VOLUME34,188CYAPPROX. FILL VOLUME37,064CYAPPROX. NET IMPORT2,876CYLANDSCAPING MATERIALSEE SCHEDULE ON3171999SDV03PUBLIC SEWER OWNER & INSPECTION CONTACT:METROPOLITAN SEWER DISTRICT OF BUNCOMBE COUNTYINSPECTOR CONTACT: MIKE STAMEY (828-768-2605)EMAIL: MIKES@MSDBC.ORGALL MODIFICATION TO THE EXISTING MANHOLE RIMELEVATIONS SHALL BE COMPLETED WITH THE UTILITYINSPECTOR PRESENT. NOTIFY INSPECTOR 48-HOURS PRIORTO SCHEDULE WORK. A FEE OF $140 IS REQUIRED FOR EACHINSPECTION AND SHALL BE PAID BY THE CONTRACTOR.REVISION HISTORYREVDESCRIPTIONISSUE TYPEDPNDFTCHKENGDATE0NEW CONSTRUCTIONPERMITTINGW18019501JRPMTPJAP11/23/20201NEW CONSTRUCTION/NCDENR PERMITTING REVISIONPERMITTING/IFCW18019501JAPMTPJAP12/17/2020 MH ID: 73-481460MH ID: 73-481459ALL PIPE IS 8" PVCMH ID: 73-481458MH ID: 73-481457MH ID: 49-480648MH ID: 49-480649MSDBC ID: 49-381959REV:THIS DRAWING ORBILL OF MATERIAL ISCONFIDENTIALAND MAY NOT BELOANED, REPRODUCEDOR COPIED, EITHERWHOLLY OR IN PART,OR MADE PUBLIC INANY MANNER WITHOUTTHE WRITTENCONSENTOF DUKE ENERGYCORPORATION.Contract:AS BUILTPRELIMINARYTITLE:LOCATION:SHEET SIZE:REGION:REV:DRAWING NUMBER:SEAL:Phone:Company:Date:CITY:COUNTY:STATE:STATION NUMBER:FILE NAME: 3171999SDVD:GFUSION FILE NAME:15574NC-SCNCFERNCLIFF RETHENDERSONMILLS RIVER5574EXISTING CONDITIONS115 KV SUBSTATIONSITE DEVELOPMENTARCH D1SDV3171999SDV023171999SDV02 NOTES:1.SURVEYOR INFORMATION IS AS NOTEDON 3171999SDV01.3.METROPOLITAN SEWER DISTRICT OFBUNCOMBE COUNTY ONLINE MAPPINGSERVICE INDICATES A PRIVATE FORCEMAIN WITH UNKNOWN SIZE AND PVCMATERIAL CROSSES THE EASTERNPROPERTY LINE APPROXIMATELY 987LF FROM BROADPOINTE DR R/W. THEPRIVATE LINE CONTINUES NORTHWESTTOWARD OLD FANNING BRIDGE ROADTO A CONTROL VALVE IDENTIFIED AS49-458296. DEPTH AND EXACTLOCATION IS UNKNOWN ANDCONTRACTOR IS RESPONSIBLE FORLOCATING PRIOR TO WORK. ALLVEHICULAR CROSSING SHALL BE STEELPLATED FOR LOAD DISTRIBUTION ANDNOT DISRUPT EXISTING FACILITIES.REVISION HISTORYREVDESCRIPTIONISSUE TYPEDPNDFTCHKENGDATE0NEW CONSTRUCTIONPERMITTINGW18019501JRPMTPJAP11/23/20201NEW CONSTRUCTION/NCDENR PERMITTING REVISIONPERMITTING/IFCW18019501JAPMTPJAP12/17/2020 LEGEND:PROPERTY LINESSETBACKBUFFERLINE R/W LIMITSDISTRIBUTION LINETRANSMISSION LINESTATION FENCEEXISTING OVERHEAD ELECTRICEXISTING UNDERGROUND ELECTRICEXISTING GAS LINEEXISTING SANITARY SEWEREXISTING FORCE MAINEXISTING WATER LINETRANSMISSION TOWERPAVED APRONABC CRUSHER RUN ACCESS DRIVEGRAVEL SUBSTATION PAD (#57STONE)DISTRIBUTION R/WPLANTING STRIPFEMA FLOODWAY LINEFEMA FLOODWAYFEMA FLOOD FRINGERIPARIAN BUFFERSTREAM BUFFERREV:THIS DRAWING ORBILL OF MATERIAL ISCONFIDENTIALAND MAY NOT BELOANED, REPRODUCEDOR COPIED, EITHERWHOLLY OR IN PART,OR MADE PUBLIC INANY MANNER WITHOUTTHE WRITTENCONSENTOF DUKE ENERGYCORPORATION.Contract:AS BUILTPRELIMINARYTITLE:LOCATION:SHEET SIZE:REGION:REV:DRAWING NUMBER:SEAL:Phone:Company:Date:CITY:COUNTY:STATE:STATION NUMBER:FILE NAME: 3171999SDVD:*FUSION FILE NAME:15574NC-SCNCFERNCLIFF RETHENDERSONMILLS RIVER5574OVERALL SITE PLAN115 KV SUBSTATIONSITE DEVELOPMENTARCH D1SDV3171999SDV03 PROJECT DATA:PROPERTY OWNER:DUKE POWER COMPANYTAX DEPT - PB05BPO BOX 1244CHARLOTTE NC 28201-1244PHONE: 704-382-4021PROJECT NAME:FERNCLIFF RET SUBSTATIONPROJECT LOCATION:PIN #: 964218797495 WONDER WAYMILLS RIVER, NC 28759PROPERTY DATA:ZONING CLASSIFICATION: MR-LITOTAL PROPERTY ACREAGE: 35.01 ACLOT 1 SUBDIVIDED PARCEL = 25.07LOT 2 SUBDIVIDED PARCEL = 9.94EXISTING IMPERVIOUS AREA = 0.00 ACPROPOSED IMPERVIOUS AREAPROPOSED ABC DRIVEWAY = 7,203 SF (0.17 AC)RESERVED BUA ABC DRIVEWAY = 1,000 SF (0.02 AC)PROPOSED STATION PAD (#57) = 86,289 SF (1.98 AC)RESERVED BUA STATION PAD (#57) = 7,000 SF (0.16 AC)TOTAL PROPOSED IMPERVIOUS = 101,491 SF (2.33 AC)PROPOSED BUA = 23.44%3171999SDV03( IN FEET )GRAPHIC SCALE1 INCH = 80 FT.0808016024040GENERAL NOTES:1.PRIOR TO COMMENCEMENT OF CONSTRUCTION, OBTAIN THE LATESTSUBSTATION PHYSICAL DESIGN FROM DUKE ENERGY. CONTRACTOR TONOTIFY THE ENGINEER OF ANY DISCREPANCIES IN STAKEOUT/CONTROL.2.ALL DETAILS SHALL BE CONSTRUCTED IN STRICT COMPLIANCE WITHPROJECT SPECIFICATIONS AND CONSTRUCTION DOCUMENTS.3.INTERMITTENT & PERENNIAL STREAMS WERE DETERMINED BY HDR DURIGNA NATURAL RESOURCE ASSESSMENT COMPLETED ON THE PROPERTY. AUSACE PRELIMINARY JURISDICTIONAL DETERMINATION (PJD) WASCOMPLETED ON FEBRUARY 12, 2019 UNDER SAW-2018-02316. NO WETLANDSARE IDENTIFIED ONSITE.SITE NOTES:1.ALL DIMENSIONS ARE 90° UNLESS OTHERWISE NOTED.2.CONSTRUCTION SHALL BE BE ESTABLISH AND VERIFY POINT OF BEGINNING(P.O.B.) AND STAKE AS INDICATED ON CONSTRUCTION DOCUMENTS PRIORTO COMMENCEMENT OF CONSTRUCTION. NOTIFY DUKE SUBSTATIONENGINEERING IMMEDIATELY OF ANY DISCREPANCIES.3.ALL DIMENSIONS ARE TO EDGE OF PAVEMENT, FACE OF BUILDING, ORCENTERLINE UNLESS OTHERWISE NOTED.4.ALL DETAILS SHALL BE CONSTRUCTED IN STRICT COMPLIANCE WITHPROJECT SPECIFICATIONS AND CONSTRUCTION DOCUMENTS.5.NON-STANDARD ITEMS (IE. PAVERS, IRRIGATION SYSTEMS, ETC) IN RIGHT-OF-WAY REQUIRE A RIGHT-OF-WAY ENCROACHMENT. AGREEMENT WITH THENORTH CAROLINA DEPARTMENT OF TRANSPORTATION BEFOREINSTALLATION.6.ALL SPOILS SHALL BE TESTED BY DUKE EHS. ALL NON CONTAMINATEDSPOILS SHALL BE STOCKPILED ONSITE AT PERMITTED STOCKPILELOCATIONS. ALL CONTAMINATED SPOILS AND DEMOLITION MATERIALSSHALL BE DISPOSED OF OFF-SITE AT A STATE APPROVED PERMITTEDLANDFILL FACILITY.7.PRIOR TO ANY EXCAVATION, GPR SHALL BE PERFORMED IN ADDITION TOCOORDINATING WITH STATE ENTITY TO LOCATE ANY EXISTINGUNDERGROUND UTILITY OR STRUCTURES/OBSTRUCTIONS. PRECAUTIONSHALL BE TAKEN DURING EXCAVATION TO PROTECT THE EXISTING UTILITIESIF ANY. ALL EXISTING UTILITIES SHALL BE FIELD VERIFIED BY THECONTRACTOR PRIOR TO CONSTRUCTION.8.CONTACT THE UTILITY COMPANY TO RELOCATE ANY EXISTING UTILITIES. ALLEXISTING FACILITIES WHICH CONFLICT WITH THE IMPROVEMENTS UNDERTHE SCOPE OF THIS PROJECT MUST BE COORDINATED WITH THE OWNERAND RELOCATED AT THE EXPENSE OF THE APPLICANT..9.BEFORE YOU DIG STOP AND CALL THE NC ONE-CALL CENTER AT1-800-832-4949. IT'S THE LAW.LANDSCAPING SECTION DETAIL:REVISION HISTORYREVDESCRIPTIONISSUE TYPEDPNDFTCHKENGDATE0NEW CONSTRUCTIONPERMITTINGW18019501JRPMTPJAP11/23/20201NEW CONSTRUCTION/NCDENR PERMITTING REVISIONPERMITTING/IFCW18019501JAPMTPJAP12/17/2020 1 INCH = 40 FT.( IN FEET )GRAPHIC SCALE040408016020REV:THIS DRAWING ORBILL OF MATERIAL ISCONFIDENTIALAND MAY NOT BELOANED, REPRODUCEDOR COPIED, EITHERWHOLLY OR IN PART,OR MADE PUBLIC INANY MANNER WITHOUTTHE WRITTENCONSENTOF DUKE ENERGYCORPORATION.Contract:AS BUILTPRELIMINARYTITLE:LOCATION:SHEET SIZE:REGION:REV:DRAWING NUMBER:SEAL:Phone:Company:Date:CITY:COUNTY:STATE:STATION NUMBER:FILE NAME: 3171999SDVD:*FUSION FILE NAME:15574NC-SCNCFERNCLIFF RETHENDERSONMILLS RIVER5574SITE PLAN115 KV SUBSTATIONSITE DEVELOPMENTARCH D 1 SDV3171999SDV043171999SDV04 LEGEND:PROPERTY LINESSETBACKBUFFERLINE R/W LIMITSDISTRIBUTION LINETRANSMISSION LINESTATION FENCEEXISTING OVERHEAD ELECTRICEXISTING UNDERGROUND ELECTRICEXISTING GAS LINEEXISTING SANITARY SEWEREXISTING FORCE MAINEXISTING WATER LINETRANSMISSION TOWERPAVED APRONABC CRUSHER RUN ACCESS DRIVEGRAVEL SUBSTATION PAD (#57STONE)DISTRIBUTION R/WPLANTING STRIPFEMA FLOODWAY LINE1 INCH = 20 FT.( IN FEET )INSET GRAPHIC SCALE02020408010REVISION HISTORYREVDESCRIPTIONISSUE TYPEDPNDFTCHKENGDATE0NEW CONSTRUCTIONPERMITTINGW18019501JRPMTPJAP11/23/20201NEW CONSTRUCTION/NCDENR PERMITTING REVISIONPERMITTING/IFCW18019501JAPMTPJAP12/17/2020 1 INCH = 30 FT.( IN FEET )GRAPHIC SCALE030306012015REV:THIS DRAWING ORBILL OF MATERIAL ISCONFIDENTIALAND MAY NOT BELOANED, REPRODUCEDOR COPIED, EITHERWHOLLY OR IN PART,OR MADE PUBLIC INANY MANNER WITHOUTTHE WRITTENCONSENTOF DUKE ENERGYCORPORATION.Contract:AS BUILTPRELIMINARYTITLE:LOCATION:SHEET SIZE:REGION:REV:DRAWING NUMBER:SEAL:Phone:Company:Date:CITY:COUNTY:STATE:STATION NUMBER:FILE NAME: 3171999SDVD:GFUSION FILE NAME:15574NC-SCNCFERNCLIFF RETHENDERSONMILLS RIVER5574SITE TURNING MOVEMENT PLAN115 KV SUBSTATIONSITE DEVELOPMENTARCH D 1 SDV3171999SDV053171999SDV05 WB-67 - Interstate Semi-TrailerOverall Length73.501ftOverall Width8.500ftOverall Body Height13.500ftMin Body Ground Clearance1.334ftMax Track Width8.500ftLock-to-lock time6.00sMax Steering Angle (Virtual)28.40°LEGEND:PROPERTY LINESSETBACKBUFFERLINE R/W LIMITSDISTRIBUTION LINETRANSMISSION LINESTATION FENCEEXISTING OVERHEAD ELECTRICEXISTING UNDERGROUND ELECTRICEXISTING GAS LINEEXISTING SANITARY SEWEREXISTING FORCE MAINEXISTING WATER LINETRANSMISSION TOWERPAVED APRONABC CRUSHER RUN ACCESS DRIVEGRAVEL SUBSTATION PAD (#57STONE)DISTRIBUTION R/WPLANTING STRIPFEMA FLOODWAY LINEREVISION HISTORYREVDESCRIPTIONISSUE TYPEDPNDFTCHKENGDATE0NEW CONSTRUCTIONPERMITTINGW18019501JRPMTPJAP11/23/20201NEW CONSTRUCTION/NCDENR PERMITTING REVISIONPERMITTING/IFCW18019501JAPMTPJAP12/17/2020 3.5' HEIGHTOF OBJECT 3.5' HEIGHT OF EYE520' LINE OF SIGHTEXISTING GRADE3.5' HEIGHT OF OBJECT LEGEND:PROPERTY LINESSETBACKBUFFERLINE R/W LIMITSDISTRIBUTION LINETRANSMISSION LINESTATION FENCETRANSMISSION TOWERPAVED APRONACCESS DRIVEGRAVEL SUBSTATION PAD1 INCH = 40 FT.( IN FEET )GRAPHIC SCALE040408016020REV:THIS DRAWING ORBILL OF MATERIAL ISCONFIDENTIALAND MAY NOT BELOANED, REPRODUCEDOR COPIED, EITHERWHOLLY OR IN PART,OR MADE PUBLIC INANY MANNER WITHOUTTHE WRITTENCONSENTOF DUKE ENERGYCORPORATION.Contract:AS BUILTPRELIMINARYTITLE:LOCATION:SHEET SIZE:REGION:REV:DRAWING NUMBER:SEAL:Phone:Company:Date:CITY:COUNTY:STATE:STATION NUMBER:FILE NAME: 3171999SDVD:GFUSION FILE NAME:15574NC-SCNCFERNCLIFF RETHENDERSONMILLS RIVER5574SIGHT DISTANCE PLAN115 KV SUBSTATIONSITE DEVELOPMENTARCH D 1 SDV3171999SDV063171999SDV06NOTE: BROADPOINTE ROAD (SR 1890) IS A TWO-LANE ROAD WITH 35 MPH SPEED LIMIT.DESIGN VEHICLE CROSSING THE ARTERIALPASSENGER VEHICLESINGLE UNIT TRUCKWB-50 TRACTOR TRAILERTWO LANESFOUR LANESSIX LANES100120130130150170170200210SIGHT DISTANCE (ft) VALUE PER 10 MPH OF ARTERIAL DESIGN SPEEDFOR APPROPRIATE ARTERIAL WIDTH OF CROSSINGCALCULATION USED FOR INTERSECTION SIGHT DISTANCE40 MPH FOR SINGLE UNIT TRUCKTWO LANES - 40 MPH / 10 * 130 = 520 FT1 INCH = 40 FT.( IN FEET )HORIZONTAL SCALE040408016020( IN FEET )VERTICAL SCALE1 INCH = 4 FT.0448162REVISION HISTORYREVDESCRIPTIONISSUE TYPEDPNDFTCHKENGDATE0NEW CONSTRUCTIONPERMITTINGW18019501JRPMTPJAP11/23/20201NEW CONSTRUCTION/NCDENR PERMITTING REVISIONPERMITTING/IFCW18019501JAPMTPJAP12/17/2020