HomeMy WebLinkAboutNC0003191_inspection 12-15-2020_20201216United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN 1 2 u 3 I NC0003191 111 121 20/12/15 I17 18 I C I 19 Ls_] 201 I
21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6
Inspection
Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved -------------------
67
I 72 I n,J I I I 71 I 74 79 I I I I I I I80
701� I 711 L
LJ L
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES permit Number)
09:30AM 20/12/15
14/01/01
New Bern Cellulose Fibers
1785 Weyerhaeuser Rd
Exit Time/Date
Permit Expiration Date
Vanceboro NC 285867606
11:15AM 20/12/15
18/04/30
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Robin L Schroeder/ORC//
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Adam Miklos,1785 Weyerhaeuser Rd Vanceboro NC 285867606//252-633-7229/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit 0 Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran 0 Facility Site Review Effluent/Receiving Wate Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Robel[rtt[ E Bullock DWR/Division of Water Qua Iity/252-948-3924/ 12/16/2020
/
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page#
NPDES yr/mo/day Inspection Type
NC0003191 I11 12I 20/12/15 117 18 i c i
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
The review period for this inspection was July 2018 through October 2020.
The current permit was set to expire on April 30, 2018. International Paper has submitted a renewal
application and the existing permit will remain effective until a new permit is issued.
The facility was judged to be COMPLIANT with NPDES permit NC0003191.
Page#
Permit: NC0003191 Owner -Facility: New Bern Cellulose Fibers
Inspection Date: 12/15/2020 Inspection Type: Compliance Evaluation
Operations & Maintenance Yes
No
NA
NE
Is the plant generally clean with acceptable housekeeping? 0
❑
❑
❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
❑
❑
❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Record Keeping
Yes
No
NA
NE
Are records kept and maintained as required by the permit?
0
❑
❑
❑
Is all required information readily available, complete and current?
0
❑
❑
❑
Are all records maintained for 3 years (lab. reg. required 5 years)?
0
❑
❑
❑
Are analytical results consistent with data reported on DMRs?
0
❑
❑
❑
Is the chain -of -custody complete?
0
❑
❑
❑
Dates, times and location of sampling
❑
Name of individual performing the sampling
❑
Results of analysis and calibration
❑
Dates of analysis
❑
Name of person performing analyses
❑
Transported COCs
❑
Are DMRs complete: do they include all permit parameters?
0
❑
❑
❑
Has the facility submitted its annual compliance report to users and DWQ?
❑
❑
0
❑
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operatc
❑
❑
❑
on each shift?
Is the ORC visitation log available and current?
❑
❑
❑
Is the ORC certified at grade equal to or higher than the facility classification?
❑
❑
❑
Is the backup operator certified at one grade less or greater than the facility classification'
0
❑
❑
❑
Is a copy of the current NPDES permit available on site?
0
❑
❑
❑
Facility has copy of previous year's Annual Report on file for review?
❑
❑
0
❑
Comment: Robin Schroeder is the ORC with Rodney Isley as the Backup ORC
Special Condition A. (15) of the NPDES permit grants International Paper a Variance to 24
hour staffing by a certified operator
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new 0 ❑ ❑ ❑
application?
Is the facility as described in the permit? 0 ❑ ❑ ❑
Page# 3
Permit: NC0003191 Owner -Facility:
Inspection Date: 12/15/2020 Inspection Type:
New Bern Cellulose Fibers
Compliance Evaluation
Permit
Yes
No
NA
NE
# Are there any special conditions for the permit?
0
❑
❑
❑
Is access to the plant site restricted to the general public?
0
❑
❑
❑
Is the inspector granted access to all areas for inspection?
0
❑
❑
❑
Comment: The current permit was set to expire on April 30, 2018. International Paper has submitted a
renewal aDDlication and the existina Dermit will remain effective until a new Dermit is issued.
Laboratory
Yes
No
NA
NE
Are field parameters performed by certified personnel or laboratory?
0
❑
❑
❑
Are all other parameters(excluding field parameters) performed by a certified lab?
0
❑
❑
❑
# Is the facility using a contract lab?
0
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
M
❑
❑
❑
Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
❑
❑
0
❑
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
❑
❑
0
❑
Comment: Nutrient samples are sent to Environment 1 for analysis and bleach plant samples are sent
to AILS for analysis
M CAM —AM -
Type of bar screen
Yes No NA NE
a.Manual
❑
b.Mechanical
Are the bars adequately screening debris?
0
❑
❑
❑
Is the screen free of excessive debris?
0
❑
❑
❑
Is disposal of screening in compliance?
M
❑
❑
❑
Is the unit in good condition?
0
❑
❑
❑
Comment: Screenings from the bar screen is sent to Craven Wood Energy
for disposal
Primary Clarifier
Yes
No
NA
NE
Is the clarifier free of black and odorous wastewater?
0
❑
❑
❑
Is the site free of excessive buildup of solids in center well of circular clarifier?
0
❑
❑
❑
Are weirs level?
0
❑
❑
❑
Is the site free of weir blockage?
0
❑
❑
❑
Is the site free of evidence of short-circuiting?
0
❑
❑
❑
Is scum removal adequate?
❑
❑
0
❑
Is the site free of excessive floating sludge?
0
❑
❑
❑
Page#
4
Permit: NC0003191 Owner -Facility: New Bern Cellulose Fibers
Inspection Date: 12/15/2020 Inspection Type: Compliance Evaluation
Primary Clarifier
Yes
No
NA NE
Is the drive unit operational?
0
❑
❑
❑
Is the sludge blanket level acceptable?
❑
❑
❑
Is the sludge blanket level acceptable? (Approximately'/ of the sidewall depth)
❑
❑
❑
Comment:
Lagoons
Yes
No
NA NE
Type of lagoons?
Aerated
# Number of lagoons in operation at time of visit?
2
Are lagoons operated in?
Series
# Is a re -circulation line present?
0
❑
❑
❑
Is lagoon free of excessive floating materials?
0
❑
❑
❑
# Are baffles between ponds or effluent baffles adjustable?
M
❑
❑
❑
Are dike slopes clear of woody vegetation?
0
❑
❑
❑
Are weeds controlled around the edge of the lagoon?
0
❑
❑
❑
Are dikes free of seepage?
0
❑
❑
❑
Are dikes free of erosion?
0
❑
❑
❑
Are dikes free of burrowing animals?
0
❑
❑
❑
# Has the sludge blanket in the lagoon (s) been measured periodically in multiple
❑
❑
❑
locations?
# If excessive algae is present, has barley straw been used to help control the growth?
❑
❑
0
❑
Is the lagoon surface free of weeds?
0
❑
❑
❑
Is the lagoon free of short circuiting?
0
❑
❑
❑
Comment:
Flow Measurement - Effluent
Yes
No
NA
NE
# Is flow meter used for reporting?
0
❑
❑
❑
Is flow meter calibrated annually?
0
❑
❑
❑
Is the flow meter operational?
0
❑
❑
❑
(If units are separated) Does the chart recorder match the flow meter?
❑
❑
0
❑
Comment: The effluent flow meter is calibrated quarterly by onsite staff. The effluent flow meter was
last calibrated on October 12, 2020.
Effluent Sampling
Is composite sampling flow proportional?
Yes No NA NE
❑ ■ ❑ ❑
Page# 5
Permit: NC0003191 Owner -Facility: New Bern Cellulose Fibers
Inspection Date: 12/15/2020 Inspection Type: Compliance Evaluation
Effluent Sampling Yes No NA NE
Is sample collected below all treatment units?
0
❑
❑
❑
Is proper volume collected?
0
❑
❑
❑
Is the tubing clean?
0
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
0
❑
❑
❑
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
0
❑
❑
❑
representative)?
Comment: Sampler temperature was 3 degrees on the day of inspection.
The samDler is on constant time and constant volume with a samDle taken every 15 minutes
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Comment:
Yes
No
NA
NE
■
❑
❑
❑
❑
❑
❑
❑
❑
❑
Page# 6