HomeMy WebLinkAboutWQ0005507_Application_19910823r MEMO TO: State Review Group Division of Environmental Management FROM: M. Noland"� Fayetteville Regional RegiWe P49 pervisor Office SUBJECT: Procedure Four (4) WQ0005507 Anson County Correctional Facility (Expansion Phase I) Sewer Extension Anson County 9/4/91 Date State Review Group Review Engineer Charles Gordner Regional Office Contact Kitty Kramer 1) Name of wastewater treatment plant to receive the wastewater: Anson County Regional Wastewater Treatment Plant 2) WWTP design capacity 3_5 MGD 3) NPDES Permit No.: NCO041408 Expiration Date: 06/30/93 SOC EMC WQ No.: SOC 89-09 Ad I Expiration Date: 12/31/95 4) Compliance Information: Present treatment plant performance for previous 12 months - beginning 01/07/91 (See attached self -monitoring data for July 1990 thru June 1991.) p °c,, 5) Quantity and type of wastewater from proposed sewers: 4-,44.0-GPD revised flow per discussion with Chuck Hizer on 9/5/91 (824 beds x bO gal. per bed). Ib" L %c ".s 101�000 rk? 6-4- fflY +moon projec4- w; k t ld cq n <�isl, �� 24�(Do-u eY �4• 1 ,..e = domestic 100% ; industrial ; other 6) Volume from previously approved projects not yet tributary to WWTP 274,140 GPD 7) Regional Recommendations: Approval x Denial MJN/AKK/tf Enclosure AUG 281991 •!""" s ENV MANAGEMENT State of North CarolinJAYETTEVILLE REG. OFFICE Department of Environment, Health and Natural Resources Division of Environmental Management 512 North Salisbury Street • Raleigh, North Carolina 27611 James G. Martin, Governor George T. Everett,Ph.D. William W. Cobey, Jr., Secretary August 23, 1991 MR AL J. LEONARD ANSON COUNTY ANSON COUNTY COURTHOUSE WADESBORO, NORTH CAROLINA 28170 Dear MR LEONARD: Director Subject: Application No. WQ0005507 Anson Co. Correctional Facility Sewers -Private Anson County The Division's Permits and Engineering Unit acknowledges receipt of your permit application and supporting materials on August 16, 1991. This application has been assigned the number shown above. Please refer to this number when making inquiries on this project. Your project has been assigned to Charles Gordner for a detailed engineering review. A technical acknowledgement will be forthcoming. If this acknowledgement is not received within thirty (30) days, please contact the engineer listed above. Be aware that the Division's regional office, copied below, must provide recommendations from the Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the Division. If you have any questions, please contact Charles Gordner at (919) 733-5083. cc: Fayetteville Regional Office Hobbs, Upchurch & Associates Sincerely, Lf� onw_c� TaDonald Safrit, P.E. Supervisor, Permits and Engineering Unit Pollution Prevention Pays P.O. Box 27687, Raleigh, North Carolina 27611-7687 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer Nglrth C&krslina Department of Environment, Health, and Natural Resources DEM USE ONLY Environmental Management Commission Permit Number: NON -DISCHARGE PERMIT APPLICATION 'In accordance with NC General Statutes Chapter 143, Article 21 County, Anson Applicant (name of board, individual, or others): Application Date: County of Anson March 5, 1991 Project (name of city, village, town, sanitary district, establishment): Sewer Improvements to Serve Anson County Correctional Center and Institute FOR: Brief Project Description: ❑ Non -Discharge Treatment/Disposal Facilities ❑ Pretreatment Facilities Installation of approximately 5.991.44 LF of ® Sewer Collection system (private) 8" gravity sewer line and associated ❑ Extension of sewer Systems (public) structures. This gravity sewer will serve the expanded Anson Correctional Center LJ Sludge Disposal and Phase I of the Anson Correctional ❑ Spray Irrigation Institute. Installation of approximately 5,259 LF of 6" force main and appurtenances. NATURE OF WASTEWATER: Pump station delivering 300 GPM against ® Domestic Sewage 115.5' of TDH. ❑ Sludge/Industrial Waste Estimated Completion Date: ❑ Other Waste August 30 1991 From (sewers, pretreatment plant): Serving (city, institution, industry): Sewers ; Anson Correctional Center Into (name of treatment plant): Average Daily Gallons Sewage or Waste Flow: Anson Co. Regional Wastewater Trmt. Plt. ; 109,680 d- At (location of plant): (NPDES No.) South Fork of Jones Creek, Anson County NCOO 41408 Name and Complete Address of Engineering Firm: Hobbs, Upchurch & Associates, P.A. Zip Code: 28388 P. 0. Box 1737. Southern Pines, North Carolina Telephone No. (919) 692-5616 Applicant assures that proposed works will be constructed, supervised, operated and maintained in accordance with approved plans and specifications or approved changes thereto. Al J. Leonard, Jr. Mail Anson County Courthouse Print Name: A ress: Title, County Manager Wadesboro, NC Zip Code: 28170 Signatu e: To-Ianhnna Nn704 / 694-2796 INSTRUCTIONS: 1. Fill-in All Spaces. If not applicable, enter N / A. 2. Secure appropriate signature (mayor/ city manager for municipality, chairman for sanitarl corporation, or legally constituted board or commission in charge of proposed works). A proper official if design engineer or other agent signs application. 3. Submit to Division of Environmental Management, Permits and Engineering Unit, P.O. Be and ALL carbon copies of the application, 3 sets of finalized plans, specifications and otl mission Rules, and permit fee. Plans and specifications must be signed and sealed by a r FOR ASSISTANCE, CALL THE STATE CENTRAL OFFICE (919) 733-5083, PERMITS & . Asheville (704) 251-6208 Mooresville (704) 633-1699 Washington (919) 94 59 Woodfin Street 919 North Main Street 1424 Carolina Avent P.O. Box 370 P.O. Box 950 P.O. Box 1507 Asheville, NC 28801 Mooresville, NC 28115 Washington,NC 2781 Fayetteville (919) 486-1541 Raleigh (919) 733-2314 Wilmington (919) 251 Suite 714 Wachovia Building 3900 Barrett Drive 7225 Wrightsville Av Fayetteville, NC 28301 P.O. Box 27687 Wilmington. NC 284( Raleigh, NC 27611 z0C) L i 2t' - IC3�Ooo CC_ < 0v_CL' (T/15- F DP12802 Wi3,401 . TERMINAL , CONN[Cl[D TC IM%/V% IW.' Q(EX88/0P OJ/I9/9i COMPLIANCE EVALUATION ANALYSIS REPORT PASE i PERMIT--N30041408 FACIi'TTY--AN%OQ CO WWTP PIPE--Owi REPORT DWlCN PERIOD9007-YiO6 LDC-- [ L���r�ON--W�DE%BORO REGIOh/COUNTY--06 V AN%ON �3(S [1A%S--4 50050 00310 00530 CWO 3i616 50060 vo3OO -503D MONTH Q/MGD DOD RE%/T%% NH3+NH4- FEC COLT CHnORINE DO CERI7DPF LIMIT % 3.5000 S A8.00 % 30.0 % 7.00 % i000.O NOL % 5.0O 90/07 i.=2 2.39 14.9 li.O 7.24 90/08 i.9741 3.14 16.2 .53 .724 90/09 1.6463 3.82 14.7 .44 .49 26.1 83.4 .657 .580 7.00 2 7.i8 2 90/10 LIMIT % 2.0767 3.5000 5.92 % 24.00 19.6 % 30.0 .i5 % 16.00 % i4.G iOOO.O .888 NOL % 7.O4 5.0O 05/11 i.6796 4.73 26.7 .13 ii.8 i.\55 7.93 90/12 1.3470 5.03 22.5 .ii 13.5 1.283 8.32 91/W 2.0351 5.60 10.`: .O4 �2.9 .88i 9.4O 0/02 91/03 2.3350 1.9570 5.82 4.87 25.1 23.7 .50 .29 10.6 22.7 i.170 1.259 9.63 7.97 LIMIT % 3.5000 % 18.00 % 30.0 % 7.00 % iOOO.O NOL % 5.0O 91/04 2'1026 4.54 22.8 .22 10.0 ' 1.268 7.90 91/85 1.9677 4.89 19.6 .13 12.7 .462 8.1O 91/06 2.2818 5.39 21.9 .32 28.5 .424 7.0., AVERAGE 1.9027 4.59 21.4 21.4 .27 .895 7.90 2 MAXIMUM 5.7300 i7.30 51.0 4.95 20650.0 3.000 11.20 2 MINIMUM .3700 LES%THAN 6.0 LE%%THAN iO.O LE%%THAN 5.20 2 UNIT MCD MG/L MG/L MG/L 0000ML MG/L MG/L 9A ' GKEX88/MP O8/29/9� COMPLIANCE EVALUATION ANALYSIS REPORT PASE 2 PERMIT--NC000408 PIPE--OOi REPORT PERIOD: 9007-9106 LOC---E FACILITY--AN%ON CO WWTP DESIGN FLOW-- 3.5000 CLASS-4 LOCATION--WADE%BORO REGION/COUNTY--06 AN%ON THP3B OOOiO 00400 00600 00665 00720 01027 0lo&: MONTH CER7DCHV TEMP PH TOTAL N PHO%-TOT CYANIDE CADMIUM CHROMIUM LIMIT NOL NOL 9.0 6.0 NOL NOL NOL NOL �OL 90/O7 25.57 7.7-6.7 5.90O i6.7000 .00i2 .0002 .Oi0O 9O/O8 2 26.60 7.8-6.6 12.800 6.6000 .0020 .0032 .0275 9O/O9 24.36 7.9-6.5 12.400 i2.2000 .0033 .0000 .0025 9O/iO 21.95 7.9-6.8 19.000 5.3000 .0165 .00OO .000O LIMIT NOL NOL 9.0 6.0 NOL NOL NOL NOL NDL 90/1i i5.47 8.0-6.5 .00O 4.5000 .0146 .0000 .03%: 9002 2 1331 7.8-7.2 i4.700 4.5000 .0095 .0000 .6i50 91/01 12.00 7.8-6.8 10.350 3.1500 .0045 .00OO .Oi45 9i/02 13.90 7.7-6.7 i6.i0O 3.8000 .0273 .0000 � .0OO� 9i/O3 2 i5.30 7.7-6.5 iO.900 2.8000 .0065 .0025 .OiY7 LIMlT NOL NOL 9.0 6.0 NOL NOL NOL NOL NOL. 0/04 i9.90 7.8-7.0 14.500 7.0000 .0088 ' .00OO .0204 91/05 22.8i 8.1-7.3 12.500 5.9000 .O175 ' .00iO .0i62 91/06 i 25.65 8.4-7.4 14.500 5.0000 .O16O .0000 .0O7O AVERAGE i i9.71 ________ ii.970 6.3875 .0iO6 .0805 .0144 MAXIMUM 2 29.00 8.400 i9.000 16.7000 .0620 .0040 MINIMUM i 8.00 6.500 5.900 2.0000 .0020 .00OC .0000 UNIT 9A DEG.0 %U MG/L MG/L MG/L MG/L MG/L ` `~-°~� --_`^�~-~-'--------. GKEX88/MP COMPLIANCE EVALUATION ANALYSIS REPORT PA"[ � PERMIT--NC0041408 PIPE--OOi REPORT PERIOD, 9007-9106 LOC---[ CO WWTP DESIGN FLOW-- 3.5000 CLASS-'; FACILITY--AN%ON LOCATION--WADE%BORO REBIO«/COUKTY--06 AN%ON Oi042 01051 OIO67 01092 MONTH COPPER LEAD NICKEL ZINC NOL NOL "Oi ` 90/07 .0560 .0100 .0500 9O/O8 .4350 .0275 .O375 .i7OO 90/09 .2725 .0100 .0225 .5475 9000 .0525 .0125 .005O .i325 LIMIT NOL NOL NOL NOL 90/11 .0680 .0160 .0460 9002 .0352 .008O .0360 .05i5 .0552 .0000 .0265 .0445 91/02 .0523 .00OO .O243 .0666 91/03 .0937 .0000 .0967 .068O LIMIT NOL NOL NOL NOL 9i/04 .0480 .0050 .0520 .i99O ' 91/05 .0587 .0265 .0327 .O797 ' 91/06 A387 .0000 .O4i7 .O6�7 AVERAGE .ii38 .0089 .0392 .i294 MAXIMUM 1.2200 .0800 .1620 i.36OO MINIMUM .0i0O .0000 .Oi00 .022O � UNIT � ` , - MG/L MG/L MG/L MWL