HomeMy WebLinkAboutNCG550431_staff report_19930902rd CC: Permits and Engineering Technical Support Branch County Health Dept. Central Files"'°'°°a '"° ��3;.• WSRO SOC PRIORITY PROJECT: No x To: Permits and Engineering Unit Water Quality Section Attention: Mack Wiggins Date: September 2, 1993 NPDES STAFF REPORT AND RECOMMENDATIOI O 3 _ O -1_ O 4 County Forsyth Permit No. PART I - GENERAL INFORMATION ' " cGa) 0'31 1. Facility and Address: Mr. Barry Knight Residence 1731 Cone Road Winston-Salem, NC 27127 2. Date of Investigation: August 31, 1993 3. Report Prepared by: Mike Mickey Environmental Specialist II 4. Persons Contacted and Telephone Number: Mr. Barry Knight, ph (919) 784-7742 5. Directions to Site: Take Highway 150 south of Winston- Salem. Exit onto Clemmonsville Road and proceed right to Old Salisbury Road. Turn left and Cone Road is 1.4 miles on the right. The residence is at the end of the road on the right. 6. Discharge Points(s), List for all discharge points: Latitude: 360 01' 1311 Longitude: 800 16' 3611 U.S.G.S. Quad No. C-17-SE U.S.G.S. Quad Name Winston-Salem West 7. Site size and expansion area consistent with application ? X Yes No If No, explain: 8. Topography (relationship to flood plain included): The house and system are located adjacent to the stream. The chlorinator tubes are 25 feet from the creek. 9. Location of nearest dwelling: Other dwellings are located to the east of Cone Road ice, 10. Receiving stream or affected surface waters: U.T. to South Fork Muddy Creek a. Classification C b. River Basin and Subbasin No.: YAD-04 C. Describe receiving stream features and pertinent downstream uses: The system discharges into the headwaters of the U.T. behind the house. A large pond is located 3/4 mile downstream. The stream flows into a cow pasture just'50 feet below the system. Part II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of Wastewater to be permitted: 450 MGD (Ultimate Design Capacity) b. Current permitted capacity of the WWTP? 450 gpd. 2. M W C. Actual treatment capacity of the current facility (current design capacity)? The sandfilter is only 90 sq. ft., but is preceded by a ground absorption system. d. Date(s) and construction activities allowed by previous A/C's issued in the previous two years. NA e. Please provide a description of existing wastewater treatment facilities; The existing facility consists of the following: a 900 gallon septic tank, an 80 foot long nitrification line, 90 sq. ft. subsurface sandfilter, tablet chlorinator w/contact tank and discharge pipe. f. Please provide a description of proposed wastewater treatment facilities. NA g. Possible toxic impacts to surface waters: NA h. Pretreatment Program (POTWs only): NA Residuals handling and utilization/disposal scheme: a. Other disposal/utilization scheme (Specify): Septage pumper for disposal in the nearest POTW. Treatment plant classification (See attached rating sheet). NA for SFR. SIC Code(s): 4952 Primary 04 Main Treatment Unit Code: 4 4 0 X 7 NPDES Permit Staff Report Version 10/92 Page 2 r PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or are any public monies involved? No 2. Special monitoring or limitations (including toxicity)? NA. 3. Important SOC, JOC or Compliance Schedule dates: NA. 4. Alternative Analysis Evaluation: Has the facility evaluated all of the non -discharge options available. Please provide regional perspective for each option evaluated. NA for existing SER. 5. Other Special Items: IV - EVALUATION AND RECOMMENDATIONS An inspection of the system on September 1, 1993, did not reveal any problems. The end of the effluent pipe could not be located _ec`dWo excessive plant growth. Observations of the U.T. revealed clear water with no solids present. WSRO recommends reissuance. Signature of report pre` rer lol, Water Quality Regional Supervisor 9, - 3 - i,3 Date NPDES Permit Staff Report Version 10/92 Page 3 A. O. EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS FINAL Permit No. NCO068829 During the period beginning on the effective date of the permit and 1<<sting until expiration, the Permittee is authorized to discharge from outfall(s) serial number 001. Such discharges shall be limited and monitored by the permittee as specified below: Effluent Characteristics Flow BOD, 5 day, 200C Total Suspended Residue NH3 as N Dissolved Oxygen" Fecal Coliform (geometric mean) Total Residual Chlorine Temperature Discharge Limitations Units (specify) Monthlyv Weekly Avg, 450 GPD 15.0 mg/I 22.5 mg/I 30.0 mg/1 45.0 mg/I 4.0 mg/I 6.0 mg/1 200.0 /100 ml 400.0 /100 ml Monitoring Re ulrements MeasurementSample 'Sam . Its Frequency Type Location ** The daily average dissolved oxygen effluent concentration shall not be less than 6.0 mg/l. The chlorinator shall be inspected weekly to ensure there is an ample supply of chlorine tablets for continuous disinfection of the effluent. The pH shall not be less than 6.0 standard units nor greater than 9.0 standard units. There shall be no discharge of floating solids or visible foam in other than trace amounts. 0 MI L XN K --RiEDBURG 2.3 Mi. 17'30" 164 Mr. Barry S. Knight Residence •4. 399 NPDES Permit No. NCO068829 Discharges into a U.T. to South Fork Muddy Creek, Class Located at 1731 Cone Road south of Winston-Salem, N.C. Forsyth County C-17-SE 39k To C 19E JI L N 9 � Wpm i JIM IF WIN I SOME' Raw. L II 391 GOR Course Discharge Point �r t(� G. 565 0 INTERIOR -GEOLOGICAL SURVEY, RESTON, VIRGINIA-1987670wm-L :566 5