Loading...
HomeMy WebLinkAboutSW3201003_ESHWT REPORT_20201103Z SUMMIT ENGINEERING. LABORATORY. TESTING September 24, 2020 Mr. David Algood Auto Finance Center, LLC 11201 East Independence Boulevard Charlotte, North Carolina 28105 Email: David.algood@autofinancecenternc.com Subject: Estimated Seasonal High Water Table (ESHWT) Determination Union County Parcel 07102296 ESHWT Union Beltway Road Union County, North Carolina SUMMIT Project No. 5918.G0799 Dear Mr. Algood: SUMMIT Engineering, Laboratory and Testing, P. C. (SUMMIT) is pleased to submit this letter summarizing our observations of the soil test boring as related to Estimated Seasonal High Water Table Elevation (ESHWT) determination in the proposed BMP pond to be constructed for the proposed project located off Union Beltway Road in Union County, North Carolina. This report contains a brief description of the project information provided to us, general site and subsurface conditions revealed during this exploration. PURPOSE OF EXPLORATION The primary purpose of this exploration was to obtain information regarding the subsurface conditions in the proposed BMP pond, assess the engineering characteristics of the subsurface materials, and determination of the estimated seasonal high water table mark (if evident). Summary of ESHWT Determination Union Countv Parcel 07102296 This report contains the following items: • Site Vicinity Map and Boring Location Plan, SUMMIT Project No. 5918.G0799 September 24, 2020 • Summary of Test Boring Observations, visual soil classifications and descriptions, • A general review of the subsurface soils and estimated seasonal high water table depth from existing ground surface (if evident), • Groundwater level measurements. EXPLORATION PROCEDURES SUMMIT visited the site on September 16, 2020 to perform a soil test boring (identified as Boring SW -I) in the proposed BMP pond. The approximate location of the boring is shown on Figure 2 — "Boring Location Plan" provided in Appendix 2. The client (Auto Finance Center, LLC) provided SUMMIT a plan sheet titled "Sketch Plan", prepared by Yarbough-Williams & Houle, Inc. dated June 20, 2020, that indicated the approximate location of the proposed detention pond. The boring location was surveyed by others. The soil test boring was performed using an ATV -mounted CME 550X drill rig and was extended to an approximate depth of 11.3 feet below the existing ground surface. Hollow -stem, continuous flight auger drilling techniques were used to advance the boring into the ground. Standard Penetration Tests (SPT) were performed within the mechanical boring continuously to the termination depth in general accordance with ASTM D 1586. When properly evaluated, the SPT results can be used as an index for estimating soil strength and density. In conjunction with the penetration testing, representative soil samples were obtained from the test location and returned to our laboratory for visual classification and potential laboratory testing. The soil samples collected were visually examined and classified in general accordance with ASTM D-2488. The Munsell Soil Color Charts (2009 Revision) were used to identify the hue, value, and chroma of soil samples. Water level measurements were attempted at the termination of drilling. The classification symbols are depicted on the "Boring Log" provided in Appendix 2. 2 Summary of ESHWT Determination SUMMIT Project No. 5918.G0799 Union County Parcel 07102296 September 24, 2020 GENERALIZED SUBSURFACE STRATIGRAPHY General subsurface conditions observed during our geotechnical exploration are described herein. For more detailed soil descriptions and stratifications at the test location, the respective "Boring Log" provided in Appendix 2 should be reviewed. The horizontal stratification lines designating the interface between various strata represents approximate boundaries. Transitions between different strata in the field may be gradual in both the horizontal and vertical directions. Beginning from the ground surface, a layer of topsoil (surficial organic soils) was observed with a thickness of approximately 2 inches. Beneath the topsoil layer, residual (undisturbed) soils were encountered that consisted of lean clays. Partially Weathered Rock (PWR) materials were encountered at an approximate depth of 5.5 feet. Auger refusal material was not encountered within the boring. GROUNDWATER LEVEL MEASUREMENTS At the time of drilling and after waiting more than 24 hours, groundwater was not observed in the boring. Please note that groundwater levels tend to fluctuate with seasonal and climatic variations, as well as with some types of construction operations. ESTIMATED SEASONAL HIGH WATER TABLE ESHWT is defined as the shallowest depth to a wet soil layer as a result of "true" or "permanent" groundwater at any time during the year. The ESHWT is typically identified with a change in the color of the soil layer due to water staining (typically, gray redoximorphic depletions and mottling). Spots or blotches of different color or shades of color interspersed with a dominant color in soil, commonly referred to as mottling. Mottling is a historic indication for the presence of groundwater caused by intermittent periods of saturation and drying, and may be indicative of poor aeration and impeded drainage. Mottling is a "general indication of groundwater" flow through this layer, but it is not known whether the groundwater flow was recent. 3 Summary of ESHWT Determination SUMMIT Project No. 5918.G0799 Union County Parcel 07102296 September 24, 2020 CONCLUSIONS Based on our observations, Estimated Seasonal High Water Table (ESHWT) indicators were not evident in soils sampled in the boring. Please note that even though we did not observe ESHWT indicators within the boring, perched water conditions can develop in soil layers above a low permeable partially weathered rock (PWR) stratum. Perched water conditions differ from the "true" or "permanent" water table. A perched water table is water standing above an unsaturated zone and is often influenced by weather conditions, and occurrence of less permeable soils. Where the ESHWT is defined as the shallowest depth to a wet soil layer as a result of "true" or "permanent" groundwater at any time during the year. The BMP designer should take into consideration that perched water conditions may exist above the low permeable stratum. The following table summarizes the results of the boring and our observations. Summary Table of the Boring Results and Our Observations Approx. Existing GW Depth Approx. Auger Boring Ground GW Depth After PWR Refusal Test Depth Elevation ATD 24 Hours Depth Depth Location (Feet)' msl 2 Feet ' Feet ' (Feet)' (Feet)' SW-1 11.3 688.8 NE NE 5.5 NE 1 Depths from existing ground surface. 2msl — Mean Sea Level - Existing ground surface elevation was estimated from the provided plan topographic information provided plan. NE — Not Encountered in boring. The analyses submitted in this report were based, in part, on data obtained from this exploration. If the above -described project conditions are incorrect or changed after the issuing of this report, or subsurface conditions encountered during construction are different from those reported, SUMMIT should be notified and these recommendations should be re-evaluated based on the changed conditions to make appropriate revisions. We have prepared this report according to generally accepted geotechnical engineering practices. No warranty, express or implied, is made as to the professional advice included in this report. 4 Summary of ESHWT Determination SUMMIT Project No. 5918.G0799 Union County Parcel 07102296 September 24, 2020 CLOSING SUMMIT appreciates the opportunity to provide our professional services for you on this project. If you have any questions concerning the information in this proposal or if we may be of further service, please contact us at 704.504.1717. Sincerely, SUMMIT ENGINEERING, LABORATORY & TESTING, P.C. N CA& �. r 'SUMMIT, r Engineering, ` i Laboratory & = = n Testing, P.C. . C-4361��` Franklin D. Newsom Staff Professional LIST OF APPENDICES Appendix 1 Figure No. 1 — Site Vicinity Map Figure No. 2 — Boring Location Plan Appendix 2 Boring Log 0 y�� G G A qA SEAL z 028423 ' `� sf ( c I- Ricky O. Coker, Vf,,ky p GO Geotechnical Enginee"i" Summary of ESHWT Determination SUMMIT Project No. 5918.G0799 Union County Parcel 07102296 September 24, 2020 SUMMIT ENGINEERING + LABORATORY . TESTING APPENDIX 1 Figures `Y � CCA �q 0 WjSti22 ell 1 Wad AL— fl V1 w aZ Y o0 N i W q t5 ~ } V j Z z V f D w tih ry w h1 0p G Ywci ap in vt r >"P � C5 n: a '�- V '• f w'f � � 1 r t � Ex. 24"R 1. STORM P E ! Val � Obi- t w CO w� I x �rn ;" ell J ! p( 0 OC / rD�� \ / J \ l 0 E5 n. -�s z C) va �W,6_ COa fit Z 0 1 cc O 4 1 � W> o z 0 V) z N 0 \ a Z \ CL m a4. ` d 1 ' Z. Zl z Z kk ` , _ 362.9� Boring location was not surveyed and should be considered approximate �y W Figure 2 Boring Location Plan Union County Parcel 07102296 ESHWT Approx. Soil Test Boring Union Beltway Road Location Union County, North Carolina �SCALE:NTS I SUMMIT Project No.: 5918.G0799 ss9 Pbg 4�- "s s 41 1 SUMMIT 3575 Centre Circle Fort Mill, South Carolina 29715 (803)504-1717 Summary of ESHWT Determination SUMMIT Project No. 5918.G0799 Union County Parcel 07102296 September 24, 2020 u u I ENGINEERING * LABORATORY * TESTING APPENDIX 2 Boring Log SUMMIT ENGINEERING, LABORATORY & TESTING, P.C. BORING NUMBER SW-1 CENTRE CIRCLE FORT FORT MILL, SOUTH CAROLINA 29715 PAGE 1 OF 1 SUMMIT 704-504-17 17 SUMMIT-COMPANIES.COM CLIENT Auto Finance Center, LLC PROJECT NAME Union County Parcel 07102296 ESHWT PROJECT NUMBER 5918.G0799 PROJECT LOCATION Union County North Carolina DATE STARTED 9/16/20 COMPLETED GROUND ELEVATION 688.8 ft HOLE SIZE 6 inches DRILLING CONTRACTOR SUMMIT GROUND WATER/CAVE-IN: DRILLING METHOD Hollow Stem Auger AT TIME OF DRILLING -- GW NE ATD LOGGED BY D. Robles CHECKED BY F. Newsom AT END OF DRILLING --- GW NE > 24 Hrs NOTES See Figure 2 "Boring Location Plan" for Approx. Boring Location AFTER DRILLING --- w o ♦ SPT N VALUE A O V x >- w 0 20 40 60 80 100 1r 0-r F: 0-0 MATERIAL DESCRIPTION w J 2 (If0 j C� O j Q LLj OU of co 0 20 40 60 80 100 J W a_ z LU Z ❑ FINES CONTENT (%) ❑ U) of 0 20 40 60 80 100 Approx. 2" of Topsoil (CL) RESIDUUM: Very Stiff Pale Brown (2.5Y, 7/4) and Yellow (2.5Y, 7/8) Sandy Lean CLAY SPT 4-9-9-9 ......... 1 (18) ................ :........ :........ ---------------------------- (CL) Stiff Brownish Yellow (10YR, 6/6), Pale Brown (2.5Y, 7/4) 2.5 and Gray (10YR, 6/1) Sandy Lean CLAY with a trace of Rock Fragments ...... .:........ :........ :........ :........ 686.3 SPT 5-6-9-13 2 (15) :........:........ . ........ (CL) Hard Brownish Yellow (10YR, 6/6), Pale Brown (2.5Y, 7/4) and Gray (10YR, 6/1) Sandy Lean CLAY with Rock Fragments 5.0 SPT 3 8-11-20-50 (19) ....................................>.> 683.8 " (ML) Partially Weathered Rock (PWR) when sampled becomes Pale Brown (2.5Y, 7/4) and Very Pale Brown (10YR, 7/3) Sandy SILT with Rock Fragments SPT15-45-50 ........ :............. ....:........ ........ 4 (50/4") » 7.5 SPT 18-32-50 ' ................. ......... :........ :........ 5 (50/5") » 10.0 - - �+ ��_ ................ :........ :................. 678.8 SPT 17-33-50 6 (50/4") » Bottom of Boring at 11.3 feet bgs, Boring Terminated 12.5 676.3