Loading...
HomeMy WebLinkAboutNC0000353_Technical Correction_20201102DocuSign Envelope ID: D526316E-6224-4FF9-953F-4lC31CFB707C ROY COOPER Governor MICHAEL S. REGAN Secretary S. DANIEL SMITH Director Mr. Michael Yarborough The Quartz Corp, USA P.O. Box 99 Spruce Pine, NC 28777-0099 Dear Mr. Yarborough: NORTH CAROLINA Environmental Quality November 2, 2020 Subject: Technical correction /Units of Measure NPDES Permit NC0000400 The Quartz Corp / Pine Mountain NPDES Permit N00000353 The Feldspar Corporation Mitchell County The NPDES program received questions from staff in the NC DEQ Asheville Regional Office regarding the Units of Measure (UoMs) in the existing versions of the subject permits. The UoMs do not reflect the data being collected for instream parameters, and this disparity is causing problems with the electronic entry and upload of instream data. A review of both permits noted that the Unit of Measure for Fluoride is shown as pounds per day in the effluent limit, but no UoM is given for the instream Fluoride samples. The Division is issuing this technical correction to clarify the correct UoM for effluent and instream monitoring in NC0000353 & NC0000400. No permit limits or effluent monitoring requirements are being changed; this action simply documents the UoMs in use since the last permit issuance in 2012. This permit modification is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U.S. Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Insert the attached pages into your permits and discard the old pa es. The modified permits include the following changes to the existing permits: ➢ The correct UoM has been added for all parameters without permit limits. ➢ Parameter codes for each parameter have been added to simplify data entry. If any parts, measurement frequencies or sampling requirements contained in this modification are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings (6714 Mail Service Center, Raleigh, North Carolina 27699-6714). Unless such demand is made, this decision shall be final and binding. D E Q�� North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 1 1617 Mail Service Center I Raleigh, North Carolina 27699-1617 N(1HTH f:A�i(1!_INA � 0­Om or eowM—W Q"I 919,707,9000 DocuSign Envelope ID: D526316E-6224-4FF9-953F-41C31CFB707C This permit is not transferable except after notice to the Division. The Division may require modification or revocation and reissuance of the permit. This permit does not affect the legal requirements to obtain other permits which may be required by any other Federal, State, or Local governmental regulation. If you have any questions concerning these changes, please contact David A. Hill [david.hill@ncdenr.gov]. Mr. Hill is currently finalizing the permit renewals for NC0000353 and NC0000400. Sincerely, DOCUSigned by: 2E35935DF84D4AE... for S. Daniel Smith, Director Division of Water Resources cc: NPDES Unit (Laserfiche) DocuSign Envelope ID: D526316E-6224-4FF9-953F-41C31CFB707C Permit Number: NC0000400 A. (1) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS -FINAL During the period beginning on the effective date of the permit and lasting until expiration, the Permittee is authorized to discharge process wastewater from mineral extraction of ore from Outfall 103. Such discharges shall be limited and monitored by the Permittee as specified below: PARAMETER EFFLUENT LIMITATIONS MONITORING REQUIREMENTS Monthly Average Daily Maximum Measurement Sample Sample [Parameter Code] Type Frequency Location` Flow [500501 1.73 MGD Continuous Recording Influent or Effluent Total Fluoride [QD951] 132 264 Weekly Composite Effluent pounds/day pounds/day Total Fluoride [C0951] Monitor & report (mg/L) Weekly Grab U & D Total Suspended Solids 1240 2480 Weekly Composite Effluent [QD5301 pounds/day pounds/day Total Suspended Solids Monitor & report (mg/L) Weekly Grab U & D C0530 Settleable Solids Monitor & report (mg/L) Weekly Grab Effluent 00545 Turbiditya [00070] Monitor & report (NTU) Weekly Grab Effluent, U & D pH [00400] > 6.0 and < 9.0 standard units Weekly Grab Effluent pH [004001 Monitor & Report (standard units) Weekly Grab U & D Chloride3 [00940] Monitor & report (mg/L) Quarterly Composite Effluent Chronic Toxicity4 Monitor & report Quarterly Composite Effluent TGP3B Notes: 1. U: upstream at least 100 yards from the outfall. D: downstream at least100 yards from the outfall. 2. This discharge shall not cause the turbidity of the receiving waters to exceed 10 NTU. If the turbidity exceeds 10 NTU due to natural background conditions, the discharge shall not cause any increase in turbidity of the receiving water (see A. (6)). 3. Chloride shall be monitored quarterly during the same months as toxicity testing. 4. Chronic Toxicity (Ceriodaphnia) Pass/Fail at 6.0% with testing in February, May, August, and November [see A (2)]. There shall be no discharge of floating solids or visible foam in other than trace amounts. 3 DocuSign Envelope ID: D526316E-6224-4FF9-953F-4lC31CFB707C Permit Number NC0000353 A. (1) EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS - FINAL During the period beginning on the effective date of the permit and lasting until expiration, the Permittee is authorized to discharge process wastewater from outfall 001. Such discharges shall be limited and monitored by the Permittee as specified below: PARAMETER [Parameter Code] EFFLUENT LIMITATIONS MONITORING REQUIREMENTS Monthly Average Daily Maximum Measurement Frequency Sample Type Sample Location' Flow [50050] 3.5 MGD Continuous Recording Influent or Effluent Total Fluoride [QD951] 174 pounds/day 348 pounds/day Weekly Composite Effluent Total Fluoride [00951] Monitor & report (mg/L) Weekly Grab U & D Total Suspended Solids [QD530] 1568 pounds/day 3137 pounds/day Weekly Composite Effluent Total Suspended Solids [C0530] Monitor & report (mg/L) Weekly Grab U & D Settleable Solids [005451 Monitor & report (mg/L) Weekly Grab Effluent Turbidity2 [000701 Monitor & report (NTU) Weekly Grab Effluent, U & D pH [00400] > 6.0 and < 9.0 standard units Weekly Grab Effluent pH [00400] Monitor & report standard units Weekly Grab U & D Chloride3 [00940] Monitor & report (mg/L) Quarterly Composite Effluent Chronic Toxicity4 [TGP3B] Monitor & report Quarterly Composite Effluent Notes: 1. U: Upstream at Feldspar's low water bridge. D: Downstream at the footbridge in Spruce Pine Park, upstream of Beaver Creek. 2. This discharge shall not cause the turbidity of the receiving waters to exceed 10 NTU. If the turbidity exceeds 10 NTU due to natural conditions, the discharge shall not cause any increase in turbidity of the receiving stream (see A. (5)). 3. Chloride shall be monitored quarterly during the same months as toxicity testing. 4. Chronic Toxicity (Ceriodaphnia) Pass/Fail at 11.0% with testing in January, April, July, and October (see A (2)). There shall be no discharge of floating solids or visible foam in other than trace amounts. Weaver, Charles From: Sent: To: Cc: Subject: Attachments: Importance: Tracking: Weaver, Charles Monday, November 2, 2020 8:21 AM 'michael.yarborough@thequartzcorp.com' Wiggs, Linda; 'james.garofalo@thequartzcorp.com'; John Silver; 'glenn.young@thequatzcorp.com'; 'pjoe8@bellsouth.net'; Moore, Tom Technical correction to NPDES permits NC0000400 and NC0000353 / UoM instream NC0000400_tech_correction_20201102.pdf High Recipient 'michael.yarborough@thequartzcorp.com Wiggs, Linda james.garofalo@thequartzcorp.com' John Silver 'glenn.young@thequatzcorp.com' 'pjoe8@bellsouth.net' Moore, Tom Davidson, Landon Delivery Delivered: 11/2/2020 8:21 AM Delivered: 11/2/2020 8:21 AM Delivered: 11/2/2020 8:21 AM Please see the attached technical correction for the subject permits. This should resolve the problems with data entry for instream data. PLEASE NOTE — I've requested that the new QD951 & C0951 parameter codes for Fluoride [mass limit] be added to BIMS/eDMR. You can manually add them until the codes appear automatically in eDMR. If you have any questions concerning this matter, simply reply to this message. PLEASE NOTE: as part of the Division's conversion to paperless communication, this email is the only notification you will be sent regarding the permit modification. No hard copy will be mailed, unless you specifically request one. Charles H. Weaver Environmental Specialist N.C. DEQ / Division of Water Resources 919-707-3616 charles.weaver(a)ncdenr.gov (mailing address) 1617 Mail Service Center, Raleigh, NC 27699-1617 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. 1 Weaver, Charles From: Microsoft Outlook To: 'pjoe8@bellsouth.net' Sent: Monday, November 2, 2020 8:21 AM Subject: Relayed: Technical correction to NPDES permits NC0000400 and NC0000353 / UoM instream Delivery to these recipients or groups is complete, but no delivery notification was sent by the destination server: 'pioe&Dbellsouth.net' (pioe&Dbellsouth.net) Subject: Technical correction to NPDES permits NC0000400 and NC0000353 / UoM instream Weaver, Charles From: Microsoft Outlook To: michael.yarborough@thequartzcorp.com'; 'james.garofalo@thequartzcorp.com'; John Silver Sent: Monday, November 2, 2020 8:21 AM Subject: Relayed: Technical correction to NPDES permits NC0000400 and NC0000353 / UoM instream Delivery to these recipients or groups is complete, but no delivery notification was sent by the destination server: 'michael.yarborough thequartzcorp.com' (michael.yarborough thequartzcorp.comj james.garofalo@thequartzcorp.com' (james.garofalo@thequartzcorp.com) John Silver (john.silver@thequartzcorp.com) Subject: Technical correction to NPDES permits NC0000400 and NC0000353 / UoM instream