Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW8120511_HISTORICAL FILE_20120613
STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW g`� dSl( DOC TYPE El CURRENT PERMIT ❑ APPROVED PLANS }� HISTORICAL FILE C ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD Permit Number SW8120511 Program Category State SW Permit Type State Stormwater Primary Reviewer kelly Johnson Coastal SW Rule Coastal Stormwater - 2008 Permitted Flow Facility Name Empire Distributors Lot 8A Central Files APS_ SWP_ 06/13/12 Permit Tracking Slip Status Project Type Active New Project Version Permit Classification 1 00 Individual Permit Contact Affiliation Major/Minor Region Minor Wilmington Location Address County 4809 Los Tortugas Or New Hanover Castle Hayne NC 28429 Facility Contact Affiliation Owner Owner Name Owner Type Empire Distributors of North Carolina Inc Non -Government Owner Affiliation Michael A Kahn 13833 Carowinds Blvd Dates/Events Charlotte NC 28273 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 06/13/12 05/29/12 06/13/12 06/13/12 06/13/20 Regulated Activities Requested/Received Events State Stormwater - HD - Detention Pond Deed restriction requested Deed restriction received Additional information requested 06/07/12 Additional information received 06/12/12 Outfall NULL Waterbody Name Stream Index Number Current Class Subbasin 1127 Floral Parkway Suite 400 Wilmington, NC 28403 (910)343-9653 (910) 343-9604 Fax John S Tunstall, PE June 8, 2012 Norris & Tunstall Consulting Engineers, P.C. Ms Kelly Johnson, Stormwater Environmental Engineer NC DENR Division of Water Quality Surface Water Protection 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Re Empire Distributors -- Lot 8A SW8 120511 Request for Additional Information Response NT Protect No 12023 Dear Ms Johnson 1429 Ash -Little River Road Ash, NC 28420 (910) 287-5900 (910) 287-5902 Fax J Phillip Norris, PE We are responding to your comments of June 7, 2012 regarding the subject protect as follows 1 General This project is not part of any overall master plan 2 Plans a The sock pipe Is for subsurface drainage of the parking area only It is not intended to convey runoff and has no inlets to allow such b The elevation has been shown on Sheet C3 and Sheet C4 c A note has been added to plan Sheet C3 regarding wetlands We are enclosing two (2) sets of revised plans for your approval Please contact us If you have any additional questions or comments Thank you for your assistance on this project Sincerely, NORRIS & TUNSTALL CONSULTING ENGINEERS, C. Phllli orns, P E 12023 06-08-12 s-sw response-Itr cc Mr Michael Kahn 1 Empire Distributors Mr Dyrc McLeod 1 Empire Distributors CEIE J U N 12 2012 8Y NCBELS License C-3641 A�� NNUCR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Charles Wakild, P E Governor Director June 7, 2012 Mr Michael Kahn, Vice President Empire Distributors of North Carolina, Inc 13833 Carowinds Blvd Charlotte, NC 28273 Subject Request for Additional Information Stormwater Project No SW8120511 Empire Distributors — Lot SA New Hanover County Dear Mr Kahn Dee Freeman Secretary The Wilmington Regional Office received and accepted a State Stormwater Management Permit Application for Empire Distributors —Lot 8A on May 29, 2012 A preliminary in-depth review of that information has determined that the application is not complete The following information is needed to continue the stormwater review General Please confirm that this project is not included in an overall master plan that has been previously permitted Plans a Sock Pipe The southern portion of the parking lot will flow to the lowest point which is adjacent to the forebay The northern portion of the parking lot drains to the east and is collected in a ditch on the eastern side of the property entering the forebay at elevation 24 65msl There is also a sock pipe in the northern part of the parking lot set level at elevation 24 0msl which drains to the emergency spillway which is not located in the pond but is set at 25 80ms1 How does the sock pipe transport water to the forebay of the pond? b Temporary Pool Elevation Please show this elevation on the plans c Wetlands Please either delineate wetlands or include a note that there are no wetlands onsite Please remember that a change to one number may have a domino effect on other numbers Please check all plans, calculations and forms and make changes as needed Please note that this request for additional information is in response to a preliminary review The requested information should be received in this Office prior to July_9, 2012, or the application will be returned as incomplete The return of a project will necessitate resubmittal of all required items, including the application fee If you need additional time to submit the information, please mail, email or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter The request must indicate the date by which you expect to submit the required information The Division is allowed 90 days from the receipt of a completed application to issue the permit Wrimington Regional Office 127 Cardinal Dnve Extension Wilmington, North Carolina 28405 Phone 910 796 72151 FAX 910-350 20041 DEN Assistance 1-877-623.6748 Internet www ncwaterqualiy org An Equal Opportunity 1 AfgrmMve Action Employer None Carolina )aturall The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215 1 and is subject to enforcement action pursuant to NCGS 143- 215 6A Please reference the State assigned project number on all correspondence Any original documents that need to be revised have been sent to the engineer or agent All original documents must be returned or new originals must be provided Copies are not acceptable If you have any questions concerning this matter please feel free to call me at (910) 796-7215 or email me at kelly p johnson@ncdenr gov CVKenson Environmental Engineer GDSlkpj S M&StormwaterTermits & Projects120121120511 HD\2012 06 addinfo 120511 cc Phil Norris, PE Wilmington Regional Office Stormwater File Page 2 of 2 Date Design Norris & Tunstall 70�f Wilmington, NC �/Ig J� Consulting Engineers, P.C. Brunswick County, NC Check Job For Job No NCZel4A e4 I I I_,-1=1i 7_ I_' wL� + I, I I I I I I I ° I —I ITV I I I i l l _+ ' I _I _ 7 -1 _ _ - _ _ ' ! I _I_J_i_Ii�_I_1=1 I I I I I —I I f_' I —I-- I— _I I—J_I —I _ T_'_irvl _i — —I— --I—I— — ——'—I-1— —�— f —I—I 1 — ,_I J i_—� I -1----l-- a----1-- -- - -- ^�'—I rvl I� L 12! i I lY I i ,_,_^'� I r I 1 �_ I- I41 _I 1 �I-1 —I �_r i'--'-1 i I—t_Ti�_1_Ii.:_i %'}I� 1—�,ry��i�-1_' r�I hI� `.I�i �i'�/IJF l/� —1 _I_i_,{�R/_f_ _I_IOMAi—I—I WJ I I i—I _ I,—I_I jji —�i;—"i,t1—� 1f—j}J'Il —.�r�-il1 !`1_i_ l_+= J1I __II --�II 1II --i1I -1I'-II i--ITI ��r�—{II--—}jf -- if II _1 -,I 1 II —I " ''I _�II _lI —I4I1 —III —I —1I —-�! E_—'I, r i—III — iII --i IIII iII i I Ir —II }I—'Ii,I --IiI —I,� --iI! --7-�II—1II!i --�—�r�—__ I1I —��-- lI - E!I --�II •_—_}1II --_a, —_— _I _ — ,+I I —L- 7— FI-=1- -I I I —I _ —T�I— Li .� ,—I I I I ��_ l 1 1— I L�_{' _'—�_ 1_ I _f I �� 1 I 1 _I_L_ _I I �_ I! _i—r 1 r — _I_ I_� I, }_'— PI _ilI�_IJ_I ! ! __ _1 _f �J_i-F-' i rt —1=1-1 —J—I ! I I i—j 1 1 I_I_� �1 I L _' III i _I—f_ L—LI I_ITT^_1 ! I ! I {�L f 1_I_I 1 i_7I —i— I 7— I I I �_� —I� � I � i— l �_I—, �I—} , ;—� I .1_ I I V f E—� o 1-7i— I— —I-1 FO �TI k- --I ! I�-�I -_-'�' rl--, ", -1I—_TiI1I1 —T —Ii o ' '—II =yI11 il I_1'_ +1` 11i �11!E-- —��1 4_ {IiH— _---_I_i _—f—�_IT yI--,-- — I I I I —7I i 1 —I —I i I _ I� �` I I IF —r—_r_ r I 1 ! i I � _—T—L——_I—r.'_1_ =17I—I—_I_177— �1 I I_V—I-1-1I—iT_ ���,,I �_II—,_V —1_i-I 17 —_I-i—I I�_I_I_I '�_1 I I rvITI i_I I I I_'_TI 1 1 j I�I I — — —, _ _ I _+— — — ' e f_ ' J e_I_L _i—� l_'�_—}I�_1 }—}—�-1 I_I IiTI_I 1—' I _ j-1� Tl� r i I I ! r I_I —I-I I f --;—,` _ W_ W 1-1 - [— I i —t — I_I I_ 1 Ti" ——i 1 117-7 _I_f I_!_I i—i_! _1_1-_:_—tI{ �-- r, _ I 1 + 1 — —'— I_ ..J_ _ I_ 3—II—' r I k �_ ITI I ,T'_t _ i m —I—rlT'——' I — — — _ ' — — I _ I_ }-1-1 71 I —I— Tr_i _I I _ I I i I i- I l l I I_I I i_I , I I 1 I_i J_I l�wl ' i I_,_,_I I r r_I I �_' '—I—�7— —_" 41�_IJ —I_I i _I —I_1-1 �i I I! I I I 1 1 1 1— I IIII 1 1 1, TI-1 1 I i !+—I �, I 11 I i—I—i �I I I +__ i"`,--r-1—r_•_I---I—I r1—� _' -1_I--i- 1I-1 1 1 ILL BY 1 i- -I-(�1 1- I I I_1 I—� I I— �r1_I_t—I_ 1`' _f i—I _ w 1_ ' ' ' i _ I I ` I�'_I_' ! , I— , I o— 1 — { I— —�_ € —I — I '_ I- 1_ 1�i_i-1—,- 1 1— I —IF i I NORRIS, KUSKE TUNSTALL CONSULTING ENGINEERS INC 5/22/2012 WET DETENTION BASIN CALCULATIONS i Protect Name Lot8A Empire Dist. NKT No 12023 Contact Person J Phillip Norris P E Phone 910 343-9653 For projects with multiple basins, specify which basin this worksheet applies to DA # 1 Description 1-year,24-hour rain event, D, Yr TSS Removal Rate Drainage Area, DA = Pre-existing Impervious Area Pre-existing Overall % Impervious, IP _ Proposed Impervious Area = Post Development Pervious Area Post Development Overall % Impervious, aty Units Notes 3 67 inches 90 00 % 1 61 ac 0 00 ac 000 % 0 91 Jac 060 ac 6006 % Volume Within 0 5 mile & drain to SA waters? Design Rainfall Depth, D, 5» = Design Rainfall Depth, D1YR = Pre-Devolpoment Runoff Volume factor, Rvpfe = Post Devolpoment Runoff Volume factor, Rvpp t = 1 5" Post-Dev Runoff Volume, V 1 5. pm, = 1 Yr Pre-Dev Runoff Volume, V 1Yr pro = 1 Yr Post-Dev Runoff Volume, V ,Yr pow = Required Storage Volume = N USE FIRST 1 5 INCH in in in/in Rvp„ = 0 05 + 0 009*IPM infin Rvpo., = 0 05 + 0 009*lp,,., fts V 15 pw=3630*D15 *Rvp,,.DA ft° V 1 yrm = 3630*D, Yr`Rvo,-DA ft° V 1 Yr p.I=3630*D1 Yr Rv,.I*DA fO Post Dev @ 15 inch Rainfall Depth 1 50 367 005 059 4,854 83 1,00578 11,878 15 4,854 83 Normal -Permanent Pool Elevation Normal -Permanent Pool surface area State Temporary Pool Elevation State Temporary Pool Surface Area Provided Storage Volume = 2465 Ift sf ft sf ft3 OKi Provided V > Required V 7,66000 2520 10,811 00 5,11926 Peak Flow Calculations C value - pre -development C value - Impervious surface C value post -developed Tc = Time of Concentration Depth @ Tc & 1-yr = d Intensity Peak, 1 YR= 1 Pre -development runoff rate (rational method) Post -development runoff rate (rational method) 0201 min inches in/hr cfs Qp,e=Cp„ x I x DA cfs Qpm=Cp., x I x DA ' 0 95 065 5 00 016 180 054 177 H 1PROJECTS12012112023 EMPIRE DISTRIBUTING -LOT A112023 CALCS112023 LotBA EMPIRE DIST - DWQ Wet Detention Basin NORRIS, KUSKE TUNSTALL CONSULTING ENGINEERS INC 5/8/2012 f Volume Calculations —All Volumes Calculated Usma Avu End Area Method Combined (Above Normal Pool) Normal -Permanent Pool Top of Vegetated Shelf Temporary Pool -Required State Storage Top of Pond Main Pond Volume (Excluding Forebay) Main Pond Bottom (Volume Ignored) Sediment Removal Bottom of Veg Shelf Normal Pool Forebay Volume (Excluding Main Pond) Forebay Bottom (Volume Ignored) Sediment Removal Normal Pool Premanent Pool Volume = Main + Forebay Total Pond Volume = Top to Normal + Main to Sediment Removal + Forebay to Sediment Removal Percent Forebay Volume (18 - 22% Required) Elevation msl Area (so Increm V Accum V 2466 7,66000 2515 10,669 00 4,58225 4,58225 2520 1Q 11 00 53700 5,119 25 28A0 22,014 00 19,695 00 24,814 25 Elevation msl Areas Increm V Accum V 1600 805001 1800 2415 4,212 001 15,427 28 15,427 28 2465 6,200001 2,60300 1 18,030 28 Elevation msl Areas Increm V Accum V 1800 375 00 2000 2465 1,460001 4,26638 4,26638 22,296 65 cf 47,110 90 1 cf 191% JOKI Average Depth & Required Surface Area Permanent Pool Area 7,660 00 sf Permanent Volume 22,296 65 cf Average Depth 291 ft Rounded Avg Depth = 3 001 ft SA/DA # from "Green Sheet" of Interpolated values for Coastal Region SA/DA at specified % impervious & 7 66 ft 90% TSS removal, NO VFS Req rounded average depth= Required Surface Area = 5,03821 sf Provided Surface Area = 1,66000 lei OKI Drawdown Calculations Drawdown Orifice Avg Head = 1/3 of Flood Pool Elev 018 ft Co = Coefficient of Discharge 060 Drawdown Time = 200 days 172.800 s Internal Diameter = 013 ft 158 in Drawdown Time = 500 days 432,000 s Internal Diameter = 008 ft 100 in Avg Internal Diameter= 129 in Design Orifice Diameter = 1.50 in OKI 001 ft Design Drawdown rate 002 cfa ,Design Drawdown time 227 days H IPROJECTS12012112023 EMPIRE DISTRIBUTING -LOT A112023 CALCS112023 Lot8A EMPIRE DIST - DWO Wet Detention Basin L is ?S PRE-D EV POST D EV A P STM POND Subcat Reach on Link Drainage Diagram for 12023 Lot8A EMPIRE DIST Prepared by Norris & Tunstail Consuiting Engineers 5/4/2012 HydroCAD® 7 10 s1n 000479 © 2005 HydroCAD Software Solutions LLC H 1PROJECTS12012112023 EMPIRE DISTRIBUTING -LOT A112023 CALCSI 12023 Lot8A EMPIRE DIST. Type IIl 24-hr 9 YR Rainfall=3 80" Prepared by Norris & Tunstall Consulting Engineers HydroCAD® 7 10 sln 000479 © 2005 HydroCAD Software Solutions LLC 5/8/2012 Time span=0 00-24 00 hrs, dt=0 05 hrs, 481 points Runoff by SCS TR-20 method, UH=SCS Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method Subcatchment 1S PRE-DEV Runoff Area=65,773 sf Runoff Depth>1 66" Tc=5 0 min CN=77 Runoff=2 91 cfs 0 208 of Subcatchment 2S POST DEV Runoff Area=65,773 sf Runoff Depth>2 82" Tc=5 0 min CN=91 Runoff--4 90 cfs 0 355 of Pond 3P STM POND Peak Elev=25 34' Storage=7,799 cf Inflow=4 90 cfs 0 355 of Primary=1 24 cfs 0 216 of Secondary=0 00 cfs 0 000 of Outflow=1 24 cfs 0 216 of H IPROJECTS12012112023 EMPIRE DISTRIBUTING -LOT A112023 CALCSI 12023 Lot8A EMPIRE DIST. Type 11124-hr 9 YR Rainfall=3 80" Prepared by Norris & Tunstall Consulting Engineers HydroCAD® 7 10 s/n 000479 © 2005 HydroCAD Software Solutions LLC _ 5/7/2012 Subcatchment 1 S: PRE-DEV Runoff = 2 91 cfs @ 12 08 hrs, Volume= 0 208 af, Depths 1 66" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0 00-24 00 hrs, dt= 0 05 hrs Type III 24-hr 1 YR Rainfall=3 80" Area (sf) CN Description _ 65,773 77 Woods, Good, HSG D Tc Length Slope Velocity Capacity Description - min (feet).___ (ftrft) (ft/sec) _(cfs)_ 50 Direct Entry, Subcatchment 1 S- PRE-DEV Hydrograph F 41 _; 0 LL 29 cfs I r I I ! I I I I Type IIII 24-hr 11 YR , Rainfal1=3.80" I 1 I I V 1 I I I I I Runoff Area=615, i773 sf Runollff V61ume=0.208 of I I I I I I I I I ! ! ! I I I I Runoff Depth>1.66, I 1 I I Tc-',5.0 niq 'n I I E I I 1 I I I I I CN-77 _I 1 1 1 I I I ! I I I I I I I I I I I I I I I I I I I II I I II I I I I I I I 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time (hours) Runoff H IPROJECTS12012112023 EMPIRE DISTRIBUTING -LOT A112023 CALCSI 12023 Lot8A EMPIRE DIST. Type lU 24-hr 1 YR Rainfall=3 80" Prepared by Norris & Tunstall Consulting Engineers HydroCAD& 7 10 sln 000479 © 2005 HydroCAD Software Solutions LLC 5/7/2012 Subcatchment 2S POST DEV Runoff = 4 90 cfs @ 12 07 hrs, Volume= 0 355 af, Depth> 2 82" Runoff by SCS TR-20 method, UH=SCS, Time Span= 0 00-24 00 hrs, dt= 0 05 hrs Type Ill 24-hr 1 YR Rainfall=3 80" Area (sfl CN Descriotion 26,273 80 >75% Grass cover, Good, HSG D 39,500 98 Paved parking & roofs _ 65,773 91 Weighted Average Tc Length Slope Velocity Capacity Description (min) (feet) (ftlft) - (ft/sec) (cfs) _ 50 Direct Entry, Subcatchment 2S. POST DEV Hydrograph 4 90 cfs Type 111124-h r 1 YR Rainfa111=3.80" RuI n'I Of Area-6073 sf I I 1 1 1 1 I RunoffWlume=0.355 of _ I I bP'Pth>2.82" Runoff 1 I I I I I I I 1 Tc=5.0 min I I I � -- CN=91 I I i i I I I I I I I I 1 i 1 I I I I 1 I I I I I I 1 I 1 I 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time (hours) — Runoff H 1PROJECTS12012112023 EMPIRE DISTRIBUTING -LOT A112023 CALCSI 12023 Lot8A EMPIRE DIST. Type 11124-hr 1 YR Rainfall=3 80" Prepared by Norris & Tunstall Consulting Engineers H droCADO 7 10 sln 000479 © 2005 H droCAD Software Solutions LLC 5/8/2012 Pond 3P• STM POND Inflow Area = 1 510 ac, Inflow Depth > 2 82" for 1 YR event Inflow = 4 90 cfs @ 12 07 hrs, Volume= 0 355 of Outflow = 1 24 cfs @ 12 45 hrs, Volume= 0 216 af, Atten= 75%, Lag= 22 4 min Primary = 1 24 cfs @ 12 45 hrs, Volume= 0 216 of Secondary = 0 00 cfs @ 0 00 hrs, Volume= 0 000 of Routing by Stor-Ind method, Time Span= 0 00-24 00 hrs, dt= 0 05 hrs Peak Elev= 25 34' @ 12 45 hrs Surf Area= 29,743 sf Storage= 7,799 cf Plug -Flow detention time= 203 1 min calculated for 0 215 of (61 % of inflow) Center -of -Mass det time= 102 0 min ( 896 9 - 794 9 ) Volume Invert Avail Storage Storage Description #1 24 65' 5,119 cf Storage between Normal Pool & Temp Stg Pool (Prismatic) Listed belo% #2 25 20' 24,313 cf Flood Storage (Prismatic) Listed below (Recalc) 29,432 cf Total Available Storage Elevation Surf Area Inc Store Cum Store feet s -ft cubic -feet cubic -feet 2465 7,660 0 0 2515 10,669 4,582 4,582 2520 10,811 537 5,119 Elevation Surf Area Inc Store Cum Store (feet) (sq-ft) (cubic -feet) (cubic -feet) - ,..,0„ _ . 2520 18,516 0 2600 20,839 15,742 15,742 2640 22,014 8,571 24,313 Device Routing Invert Outlet Devices #1 Primary 24 65' 15 0" x 25 O' long Culvert RCP, square edge headwall, Ke= 0 500 Outlet Invert= 24 62' S= 0 0012'1' Cc= 0 900 n= 0 011 Concrete pipe, straight & clean #2 Device 1 24 65' 1 5" Vert NCDENR ORIFICE C= 0 600 #3 Device 1 25 25' 4.00' x 4 00' Horiz TOP OF BOX Limited to weir flow C= 0 600 #4 Secondary 25 80' 25 0' long x 15 0' breadth Emergency Spillway Head (feet) 0 20 0 40 0 60 0 80 100 120 140 160 Coef (English) 2 68 2 70 2 70 2 64 2 63 2 64 2 64 2 63 Primary OutFlow, Max=1 24 cfs @ 12 45 hrs HW=25 34' (Free Discharge) r2=NCDENR ulvert (Barrel Controls 124 cfs @ 2 6 fps) ORIFICE (Passes < 0 05 cfs potential flow) 3=TOP OF BOX (Passes < 148 cfs potential flow) ec ,ndary OutFlow, Max=O 00 cfs @ 0 00 hrs HW=24 65' (Free Discharge) =Emergency Spillway ( Controls 0 00 cfs) H 1PROJECTS12012112023 EMPIRE DISTRIBUTING -LOT A112023 CALCSI 12023 Lot8A EMPIRE DIST Type 11124-hr 1 YR Rainfa!!=3 80" Prepared by Norris & Tunstall Consulting Engineers HydroCADO 7 10 sin 000479 © 2005 HydroCAD Software Solutions LLC 5/8/2012 3 LL I Pored 3P. STNI POND Hydrograph Inflow Area=1.510 ac Peak Elev=25.34' Storage=7,799 cf iwzlrrl 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Time (hours) ary H 1PROJECTS12012112023 EMPIRE DISTRIBUTING -LOT A112023 CALCSI 12023 Lot8A EMPIRE DIST. Type III 24-hr 1 YR Rainfall=3 80" Prepared by Norris & Tunstall Consulting Engineers H droCADO 7 10 sh 000479 © 2005 H droCAD Software Solutions LLC 5/8/2012 Hydrograph for Pond 3P: STM POND Time Inflow Storage Elevation Outflow Primary Secondary (hours) (cfs) (cubic -feet) (feet) (cfs) _ (cfs) (cfs) 000 000 0 2465 000 000 000 050 000 0 2465 000 000 000 1 00 000 0 2465 000 000 000 1 50 000 0 2465 000 000 000 200 000 0 2465 000 000 000 250 000 0 2465 000 000 000 300 000 0 2465 000 000 000 350 000 0 2465 000 000 000 400 000 0 2465 000 000 000 450 000 0 2465 000 000 000 500 000 1 2465 000 000 000 550 001 9 2465 000 000 000 600 001 26 2465 000 000 000 650 002 53 2466 000 000 000 700 003 94 2466 000 000 000 750 004 153 2467 000 000 000 Boo 005 230 2468 000 000 000 650 007 334 2469 000 000 000 900 010 476 2471 001 001 000 950 012 661 2473 001 001 000 1000 016 894 2476 001 001 000 1050 021 1,194 2480 002 002 000 11 00 028 1,596 2484 002 002 000 11 50 047 2,205 2491 003 003 000 1200 334 4,631 2515 004 004 000 1250 099 7,776 2634 1 23 123 000 1300 043 7,045 2530 069 069 000 1350 034 6,752 2529 043 043 000 1400 027 6,626 2528 033 033 000 1450 024 6,545 2528 028 028 000 1500 021 6,484 2527 024 024 000 1550 018 6,430 2527 021 021 000 1600 015 6,378 2527 018 018 000 1650 013 6,335 2527 015 015 000 1700 012 6,306 2526 0 13 013 000 1750 010 6,281 2526 012 012 000 1800 009 6,253 2526 Oil Oil 000 1850 008 6,223 2526 010 010 000 1900 008 6,201 2526 009 009 000 1950 008 6,183 2526 009 009 000 2000 007 6,167 2526 008 008 000 2050 007 6,153 2526 008 008 000 2100 007 6,140 2525 007 007 000 2150 006 6,129 2525 007 007 000 2200 006 6,119 2525 007 007 000 2250 006 6,109 2525 006 006 000 2300 005 6,099 2525 006 006 000 2350 005 6,089 2525 006 006 000 2400 005 6,079 2525 005 005 000 H 1PROJECTS12012112023 EMPIRE DISTRIBUTING -LOT A112023 CALCSI 12023 Lot8A EMPIRE DIST Type IN 24-hr 9 YR Rainfall=3 80" Prepared by Norris & Tunstall Consulting Engineers HydroCADO 7 10 sln 000479 p 2005 HydroCAD Software Solutions LLC 5/4/2012 Elevation Storage (feet) (cubic -feet) 2465 0 2467 154 2469 311 2471 470 2473 632 2475 796 2477 963 2479 1,131 2481 1,303 2483 1,476 2485 1,652 2487 1,831 2489 2,012 2491 2,195 2493 2,381 2495 2,569 2497 2,759 2499 2,952 2501 3,148 2503 3,345 2505 3,545 2507 3,748 2509 3,953 2511 4,160 2513 4,370 2515 4,582 2517 4,796 2519 5,011 2521 5,305 2523 5,676 2525 6,049 2527 6,422 2529 6,797 2531 7,174 2533 7,551 2535 7,929 2537 8,309 2539 8,690 2541 9,072 2543 9,455 2545 9,839 2547 10,224 2549 10,611 2551 10,999 2553 11,388 2555 11,778 2557 12,169 2559 12,561 2561 12,955 2563 13,350 2565 13,745 Stage -Area -Storage for Pond 3P STM POND Elevation Storage (feet) (cubic -feet) 2567 14,142 2569 14,541 2571 14,940 2573 15,341 2575 15,742 2577 16,145 2579 16,549 2581 16,954 2583 17,361 2585 17,768 2587 18,177 2589 18,587 25 91 18,998 2593 19,410 2595 19,823 2597 20,237 25 99 20,653 2601 21,070 2603 21,488 2605 21,907 2607 22,327 2609 22,749 2611 23,171 2613 23,595 2615 24,020 2617 24,446 2619 24,874 26 21 25,302 2623 25,732 2625 26,163 2627 26,595 2629 27,028 2631 27,462 2633 27,898 26 35 28,335 26 37 28,773 26 39 29,212 A F-Filed Annual Report 4940600 BUSINESS CORPORATION Do not data enter manually ANNUAL REPORT NAME OF BUSINESS CORPORATION Empire Distributors ojNorth Carolina, Inc FISCAL YEAR ENDING 20121231 STATE Ol' INCORPORATION GA SECRE I ARY OF STA FE CORPORATE ID NUMBER 0047286 NA I URE OF BUSINLSS Wine/Malt Beverage Dist REGISTERED AGEN C GUTHRIE, DENNIS L REGISTERED OFFICE MAILING ADDRESS 719 East Blvd Charlotte, NC 27610 REGISTERED OFFICE STREET ADDRESS 719 East Blvd Charlotte, NC 28203-5113 Mecklenburg County PRINCIPAL OFFICE I ELEPHONE NUMBER (704) 588-9461 PRINCIPAL OFFICE MAILING ADDRESS 13833 Carowinds Blvd Charlotte, NC 28273 PRINCIPAL OFFICE STREET ADDRESS 13833 Carnwindc Blvd Charlotte, NC 28273 PRINCIPAL OFFICERS Name David B Kahn Title President Address 13833 Carowinds Blvd Charlotte, NC 28273 Name Michael A Kahn Title Vice President Address 13833 Carowinds Blvd Charlotte, NC 28273 CERTIFICATION OF ANNUAL REPORT MUST BE COMPLETED BY ALL BUSINESS CORPORATIONS David B Kahn FORM MUST BE SIGNED BY AN OFFICER OF THE CORPORATION David B Kahn 5/16/2012 DATE President TYPE OR PRINT NAME TYPE OR PRINT TITLE ANNUAL REPORT FEE E-Paid MAIL TO Secretary of Stale • Corporations Division - Post Office Box 29525 • Rakish, NC 27626-0525 I SITE VICINITY MAP N.T.S. "�&cj f,, Tar4i!U 5 C%TLS- d& W,4 � �k, r t (-5cl-li r4l h v f, bh 6 r n 0- f4 b14 A o fib« n} lflliJ e��. �f �• ,� �Q` be-/v 1. okk 51aq I la �►rnw11t - zv�m �«- Nae R %s c6A3 (nQ;,r) O �wST►N� C�.AOE 38,4 ms I &(-� a,(v a � ins 2L� a ms 1 iolt, May 17, 2012 Empire Distributors of NC, Inc 3755 Atlanta Industrial NW Parkway Atlanta, Georgia 30331 Attention Mr Dyrc McLeod Corporate Director of Operations Reference Seasonal High Water Table Evaluation Empire Distributors Truck Parking Lot 4809 Las Tortugas Drive Castle Hayne, North Carolina S&ME Project Number 1061-12-215 Dear Mr McLeod MAY 2 4 f3Y S&ME, Inc (S&ME) is pleased to provide this report for seasonal high water table evaluation services at the above -referenced site S&ME was requested by you to perform these services in preparation for the planned site improvements S&ME has conducted these services in general accordance with S&ME Proposal 042A-12 (Additional Services) dated May 9, 2012 PROJECT BACKGROUND The project site is located on the north side of Las Tortugas Drive, approximately 200 feet east of its intersection with Barbados Drive in Castle Hayne, North Carolina The site is currently developed woodland Mr Jody Bland with Norris & Tunstall Consulting Engineers, P C provided us with a copy of a site plan showing the location of the proposed wet detention basin and the test location FINDINGS The seasonal high water table evaluation was performed on May H, 2012 by advancing a hand auger boring to a depth of approximately 24 inches below the existing ground surface at the test location We approximated the location in the field using the provided site plan and existing features in the field Soils were evaluated under the guidance of a Licensed Soil Scientist for evidence of seasonal high water table influence This evaluation involved looking at the actual moisture content in the soil and observing the matrix and mottle colors Depending on the soil texture, the soil color will indicate processes that are driven by seasonally high water table fluctuations, such as iron reduction and oxidation and organic matter staining S&ME, INC / 3006 Hall Waters Drive, Suite 1001 Wilmington NC 28405-8786 / p 910 799 99451 f 910 799 99581 www smeinc com Seasonal High Water Table Evaluations SBME Protect No 1061-12-215 Empire Distributors Trucking Parking Area, Castle Rayne, North Carolina May 17, 2012 A hand Hugel boimg piofile sheet, xvliic.h piovides a desciiptroil of the obscived soil hortzotis and the determined seasonal high water table, has been preluded with this iepoit The soil at the test location (13-1) was observed to imige Iiom a loamy Surface horizon to fine sand and sandy loam subset lace hoiizaiis A Slightly cemented otg,lim pan was encountered at appio\imately 12 inches below ilie existing giowid Stu face The seasonal high water table was detei mined to be appiommately 12 inches below the eNistnib giound sul face at the test location See Figure 1 (attached) tot the appiommate test location 7 he plovuled site plan Showed the presence of an appiommately 4 to 5 foot deep ditch Willi flow to the 1101111 which passes tluough the western side of the proposed ielemion bond and continues north An appioximately G foot deep chic h is piesent acios5 Las Toitiigas Ditve fiom the site and is less than 100 feet fiom the proposed tetentmn pond The presence of both of these ditches Was conlitmed m the field These ditches may be draining the atea of the pioposed retention pond anti iesulttiig rn a seasonal high watet table that i5 deepet thin what the soil chioma fiom out evaluation nldicates The Noith Catolma Depattment of Environment and Natural Resouices Best Management Piac.tices (BMP) \Manual States that stoimwatet devices should not be located in tuivActional features (i e wetlaods, stteam5, Surface waters) It is out uncletst,mchiig that the on -Site ditch is not a 1mischctional tecitme Please note that gloundwatel levels fluctuate tot numetous seasons, and these findings do not indicate that gioundwatct level-, have not of Will not i ise above the noted depths Closing S&N41- appreciates the opportunity to plovidC these SCivic.es to you If you have any questions, please contact us Sincerely, SRWE, lnc. qiM, � (20/�'r4—F W' �ICoaC auasteit Robert P WiIIcov, 1i , L S S TES Protect \Managei Senioi Soil Scientist PAM RP V/pis Attachments Figuie I Appiommiale test Lorilion Sketch Soil Boi m,- Piotile L O SITE f v V t o O V1GIW(TYMAP iA ✓r B-1 ti GOitc�a+ rum+ ` t M a _ E E � P � ` ! • e r -a-` � �` � Jr II �w � W /% 1,1 r _ — — � � Y— — � , - _—��r� `"� � 1 _ rl! � �• `r c i . if T �r/lruyir J � � V - -�_ .� »���>m n�• ` � J Y � v l 1r� � cress cwro+d�� .. "� (/ _ • Y__�,' � «--_ ' � `- J I /d7 J�J�rrlrr 1Rp T. ✓ n'pG1•`ocr t _Y^E .war' .nai r ,+'rrr r' yI Ir N l,rr1 r _ z- 'C Ste} �r rr' vMi%ui w - ^ a FG �" 3 •'-.'i �^ .y.._ 1 F /j A !/!I' _14 I N I r I LEGEND - - - I = -- —• r — , , _ ,-----------------------------� ; a II RESS ORAYAs` Ei=Ea BrJi1i_va�n E717EnJ ]I+ I I 00 WDT USE L9mSMCMN —— — — — — — — — — — — — — — — — ---- — SCALE V = 30 C3 Note Drawing provided to S&ME by Norms & Tunstall Consulting Engineers, P C ® Approximate location SCALE NOT TO SCALE APPROXIMATE TEST LOCATION SKETCH FIGURE of seasonal high water EMPIRE DISTRIBUTORS TRUCK PARKING LOT NUMBER CHECKED BY RPW table evaluation *S&MEI 4609 LAS TORTUGAS DRIVE DRAWN BY PAM CASTLE HAYNE, NORTH CAROLINA 1 DATE 5-11-12 S&ME PROJECT NUMBER 1061-12-215 May 17, 2012 Empire Distributors of NC, Inc 3755 Atlanta industrial NW Parkway Atlanta, Georgia 30331 Attention Mr Dyrc McLeod Corporate Director of Operations Reference: Seasonal High Water Table Evaluation Empire Distributors Truck Parking Lot 4809 Las Tortugas Drive Castle Hayne, North Carolina S&ME Project Number 1061-12-215 Dear Mr McLeod RECEIVE MAY 2 4 2011 S&ME, Inc (S&ME) is pleased to provide this report for seasonal high water table evaluation services at the above -referenced site S&ME was requested by you to perform these services in preparation for the planned site improvements S&ME has conducted these services in general accordance with S&ME Proposal 042A-12 (Additional Services) dated May 9, 2012 PROJECT BACKGROUND The project site is located on the north side of Las Tortugas Drive, approximately 200 feet east of its intersection with Barbados Drive in Castle Hayne, North Carolina The site is currently developed woodland Mr Jody Bland with Norris & Tunstall Consulting Engineers, P C provided us with a copy of a site plan showing the location of the proposed wet detention basin and the test location FINDINGS The seasonal high water table evaluation was performed on May It, 2012 by advancing a hand auger boring to a depth of approximately 24 inches below the existing ground surface at the test location We approximated the location in the field using the provided site plan and existing features in the field Soils were evaluated under the guidance of a Licensed Soil Scientist for evidence of seasonal high water table influence This evaluation involved looking at the actual moisture content in the soil and observing the matrix and mottle colors Depending on the soil texture, the soil color will indicate processes that are driven by seasonally high water table fluctuations, such as iron reduction and oxidation and organic matter staining S&ME INC / 3006 Hall Waters Dnve, Sude 1001 Wilmington NC 2B405-8786 / p 910 799 99451 f 910 799 99581www smeinc corn Seasonal High Water Table Evaluations SBME Protect No 1061 12-215 Empire Distributors Trucking Parking Area, Castle Hayne, North Carolina May 17, 2012 A htuid augei boi mg profile sliect, which pi ovides a desct iption of the obsci ved soil hotizons and the determined seasonal high watei table, has been included With this tepoil The soil at the test location (B-1) was obseived to iange from a loamy suiface hoiizoi to fine sand and sandy loam sibsui iace hot Mons A shglltly cemented of ginuc pan %vas eneounteied tit appiommately 12 inches below the existing giounci sut face The seasonal high water table was deteim med to be appioxmiately 12 itiehes below the earsting giounci sin tote at the test location See riguie I (attached) lot the appioi,imate test location the piovicled site plan showed the presence of ai appio\imately 4 to S foot deep ditch with flow to the north which passes tluough the western side of the proposed ieteition pond and coi roues iloith An appiommately 6 foot deep dm-h is present acioss Las Tottugas Diive hom the site and is less (hall 100 feet from the pioposed ietentioii pond The piesence of both of these thtc,hes was coniit med m the field These ditches may be diammg the area of the pioposed ieterition pond anti resulting in a seasonal high watet table that is deeper thin what file soil chi oma fiom out evaluatiai indicates The Noith Caiolrna Department of Divuomnent and Nattual Resources Best Mariagemem Piactices (BMP) Manual states that stotinvater devices should not be located in liuisdictronal features (i e W011111ds, stie:inis, surface valets) It is out undetstanduig that the on -site ditch is not a fuiisdictimml feature Please iotc that giouiidwatei levels fluctuate f'oi numeious teasons, and these finding~ do not indicate that gioimdwatei levels have not of will not iise above the noted depths Closing S&IvIR appieciates the oppoitunity to piovide these setvrc.es to you II you have any questions, please contact Its Sineelely, S&iVIE, Inc. Paul Masteii Pi olect Manager PALM f2MIiis PC) &-q-F W, IICOK Robeit P Willcox, It , L S S Senior Soil Scientist Attachments Fibme I - Appiommale I est Local ion Sketch Soil Boling Piofite 7m5 Location B-1 TABLE i Seasonal High Water Table Evaluation Soil Descriptions Empire Distributors Truck Parking Area 4809 Las Tortugas Drive Castle Hayne, North Carolina S&ME Project No 1061-12-215 Matrix Mottle Depth Hue/Value Hue/Value Horizon Inches /Chroma /Chroma A 0-6 2 5Y 2/1 E 6-12 1OYR 5/1 Bh 12-24+ 1 OYR 2/1 1OYR 5/1 Texture/Structure Black loamy sand, granular, very friable Gray fine sand, single grain, loose Black sandy loam, moderate angular blocky, firm, gray sandy seams present Seasonal High Water Table = 12" below the existing ground surface s SITE 2 YI[ mrrY YAP f G yr ♦ % W G r d W a / �' _ r i �� � ♦w 7 1 ♦ r r l I , p 4 y O — — — — —.,.-ram. — — - I ... ! l - r• V1 �17��- ! �•'�-I 0-, —--� --may '_!r�j a. I I dli�ilfrr -� — � r/ �� -ruX t1GiwL e Orti nC []CiXX: ObM 1/ , I!l11� rw �-Mi% r� t � -� yq -1�J0� s�.sa -1� , J [� •i I' ! I �Ff1 fl fr i ^z� L r Sl ` �l !' f P'y O.a, I [ rl�' �Yli r 1 �Il 1! 1 !I Vl .r1 z ^ %� RLEGENO _ - I f 12M - FSS pRA1y1M' FaIEa'�4S BCXJL_V__ArEx1EA51%—'I_ ' I I I �F0 00 NOT u5E I COMCIpy 4,! — _ — _ — — __ — SCALE 1' = 36 Note Drawing provided to S&ME by Norris & Tunstall Consulting Engineers, P C Approximate location SCALE NOT TO SCALE APPROXIMATE TEST LOCATION SKETCH FIGURE of seasonal high water EMPIRE DISTRIBUTORS TRUCK PARKING LOT NUMBER CHECKED BY RPW 4809 LAS TORTUGAS DRIVE table evaluation *S&ME1 DRAWN BY PAM CASTLE HAYNE, NORTH CAROLINA 7 DATE 5-11-12 1 S&ME PROJECT NUMBER 1061-12-215 Johnson Kell From Johnson, Kelly Sent Tuesday, May 29, 2012 1 02 PM To 'Phil Norris' Subject RE Empire Distributors, Lot 8A OK thanks i will give it to admen to log in and be assigned to someone 7 From: Phil Norris [mailto pnorris@ntengineers com] Sent: Tuesday, May 29, 2012 10 58 AM To: Johnson, Kelly Subject: RE Empire Distributors, Lot 8A Kelly, The existing grade is approximately 28 2 feet where the boring was made This would put the SHWT at 24 2 feet or so We have set the permanent pool elevation at 24 65 feet This is within 6 inches of the SHWT so should be acceptable Thanks, Phil Please note my new address rs onorris@ntenaineers com J Phillip Norris, P E Norris & Tunstall Consulting Engineers, P C 1429 Ash Little River Road Ash, NC 28420 910-287-5900 (phone) 910-287-5902 (fax) It is the professional opinion of Norris & Tunstall Consulting Engineers, P C and Norris, Kuske & Tunstall Consulting Engineers, Inc that this electronic information provides design information current as of the date of its release It shall be the responsibility of the party receiving the data to examine it to see that it contains the necessary files and information requested In transferring the files in electronic media format, Norris & Tunstall Consulting Engineers, P C and Norris, Kuske & Tunstall Consulting Engineers, Inc makes no representations as to the usability or readability of documents resulting from the use of software application packages, operating systems, or computer hardware differing from those used by Norris & Tunstall Consulting Engineers, P C and Norris, Kuske & Tunstall Consulting Engineers, Inc in the preparation of such data From: Johnson, Kelly [mailto kelly_p.iohnson@ncdenr gov] Sent: Tuesday, May 29, 2012 9 54 AM To: Phil Norris Subject: FW Empire Distributors, Lot 8A Phil, Vince went out there this morning and found the SHWT to be 4-5ft below existing grade From your soils report, it looks like you found the same But, I need to have that in terms of elevation What is the elevation of the existing grade? :X From: Johnson, Kelly Sent: Friday, May 25, 2012 10 29 AM To: 'Phil Norris' Cc: Lewis, Vincent Subject: RE Empire Distributors, Lot 8A Phil, Vince said that he will go out there and take a look Thanks, KJ From: Phil Norris [madto-pnorrisOntengineers com] Sent: Thursday, May 24, 2012 3 05 PM To: Johnson, Kelly Subject: RE Empire Distributors, Lot 8A Kelly, This is a standalone project if you read the report you will see that the soil color indicates a SHWT at 12" below existing grade However, this site has numerous ditches that have modified the drainage We believe the SHWT to be around 24 5±" Do we need to get Vince Lewis to visit the site? Phil Please note my new address is ignorrrs(EDntenarneers com J Phillip Norris, P E Norris & Tunstall Consulting Engineers, P C 1429 Ash Little River Road Ash, NC 28420 910-287-5900 (phone) 910-287-5902 (fax) It is the professional opinion of Norris & Tunstall Consulting Engineers, P C and Norris, Kuske & Tunstall Consulting Engineers, Inc that this electronic information provides design information current as of the date of its release It shall be the responsibility of the party receiving the data to examine it to see that it contains the necessary files and information requested In transferring the files in electronic media format, Norris & Tunstall Consulting Engineers, P C and Norris, Kuske & Tunstall Consulting Engineers, Inc makes no representations as to the usability or readability of documents resulting from the use of software application packages, operating systems, or computer hardware differing from those used by Norris & Tunstall Consulting Engineers, P C and Norris, Kuske & Tunstall Consulting Engineers, Inc in the preparation of such data From: Johnson, Kelly [mailto kelly p johnsonCa)ncdenr.aovl Sent: Thursday, May 24, 2012 2 05 PM To: Phil Norris Subject: Empire Distributors, Lot 8A Phil, We received this application today, and I have two quick questions for you 1) Subdivision Is this lot in a permitted master permit, or is it just a stand-alone project? 2) SHWT What is the SHWT elevation? The soils report says it is 12" below existing grade, but it doesn't provide elevation information Thanks, KJ *** My email has changed to kelly p johnsoni?ncdenr.gov 1-- itL .tW Oh KSOI& Kelly Johnson Environmental Engineer Division of Water Quality Stormwater Permitting 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Office* 910 796.7332 Fax- 920,350.2004 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties No virus found in this message Checked by AVG - www avg com Version 2012 0 2171 / Virus Database 2425/5019 - Release Date 05/24/12 No virus found in this message Checked by AVG - www avg com Version 2012 0 2171 / Virus Database 2425/5030 - Release Date 05/29/12 q STORMWATER SYSTEM & EROSION CONTROL NARRATIVE EMPIRE DISTRIBUTORS -- LOT 8A New Hanover County, North Carolina For Empire Distributors of North Carolina, Inc 13833 Carowmds Boulevard Charlotte, NC 28273 704-588-9463 CARP ft 11966 " 18- r�-Q �!" O� ' pH1LLIP May 2012 Prepared by NORRIS & TUNSTALL CONSULTING ENGINEERS, P.C. 1127 Floral Parkway, Suite 400 Wilmington, North Carolina 28403 (910) 343-9653 (910) 343-9604 (Fax) License # C-3641 N&T Project No 12023 R ECEIVE' MAY 2 4 1011 BY.— NARRATIVE DESCRIPTION The project site is a 165 acre tract located in Island Park Lot 8A in New Hanover County The soils of the site consist of silty loamy soils and grades ranging from 0 5% to 2% Approximately 166 acres will be graded to allow construction of a paved parking lot The runoff from the site is estimated using the rational method 10-year design storm and rainfall data for the area Construction is scheduled to begin as soon as all permits and approvals are obtained The project consists of a parking lot expansion and stormwater pond Approximately 1 66 acres will be disturbed and 0 89 acres (54%) will be covered by impervious surfaces EROSION CONTROL MEASURES The attached plans and specifications outline the requirements for erosion control measures Silt fencing will be provided where stormwater would be expected to sheet flow from disturbed areas directly to adjacent property Gravel check dams will not be provided unless the Contractor has to temporarily discharge into an open ditch instead of the proposed storm drain outfall The detention pond will be used as a silt basin during construction and restored to its design contours prior to completion A gravel construction entrance will be constructed at the adjacent existing driveway entrance Maintenance will be provided by the grading contractor and developer STORMWATER MANAGEMENT MEASURES The project site is located in New Hanover County Land disturbing on the site will exceed one acre, which requires the site to comply with the State Regulations The stormwater runoff from the development will be directed to the wet detention pond The stormwater detention pond was designed to accommodate this site at 54% impervious area lot coverage CONSTRUCTION SEQUENCE The Contractor will install the gravel construction entrance and silt fence prior to beginning any clearing and grading operations Additional silt fence will be installed when and if conditions warrant during construction The detention pond/silt basin will be constructed immediately after that portion of the site is cleared, and outlet structure with protection will be installed Disturbed areas will be landscaped or seeded upon completion EROSION CONTROL NOTES AND MAINTENANCE PLAN All erosion and sediment control measures will be checked for stability and operation following every runoff -producing rainfall, but in no case, less than once every week and within 24 hours of every half -inch rainfall 2 All points of egress will have construction entrances that will be periodically top - dressed with an additional 2 inches of #4 stone to maintain proper depth They will be maintained in a condition to prevent mud or sediment from leaving the site Immediately remove objectionable material spilled washed or tracked onto the construction entrance or roadways 3 Sediment will be removed from hardware cloth and gravel inlet protection, block and gravel inlet protection, rock doughnut inlet protection and rock pipe inlet protection when the designed storage capacity has been half filled with sediment Rock will be cleaned or replaced when the sediment pool no longer drains as designed Debris will be removed from the rock and hardware cloth to allow proper drainage Silt sacks will be emptied once a week and after every rain event Sediment will be removed from around beaver dams, dandy sacks and socks once a week and after every rain event 4 Diversion ditches will be cleaned out immediately to remove sediment or obstructions from the flow area The diversion ridges will also be repaired Swales must be temporarily stabilized within 21 calendar days of cease of any phase of activity associated with a swale 5 Sediment will be removed from behind the sediment fence when it becomes half filled The sediment fence will be repaired as necessary to maintain a barrier Stakes must be steel Stake spacing will be 6 feet max with the use of extra strength fabric, without wire backing Stake spacing will be 8 feet max when standard strength fabric and wire backing are used If rock filters are designed at low points in the sediment fence, the rock will be repaired or replaced if it becomes half -full of sediment, no longer drains as designed or is damaged 6 Sediment will be removed from the sediment basin when the design storage capacity has been half filled with sediment Rock will be cleaned or replaced when the sediment pool no longer drains or if the rock is dislodged Floating skimmers will be inspected weekly and will be kept clean Land Quality Requires 7 All seeded areas will be fertilized, reseeded as necessary and mulched according to specifications in the vegetative plan to maintain a vigorous, dense vegetative cover All slopes will be stabilized within 21 calendar days All other areas will be stabilized within 15 working days Water Quality Requires 8 All seeded areas will be fertilized, reseeded as necessary and mulched according to specifications in the vegetative plan to maintain a vigorous, dense vegetative cover All perimeter dikes, swales, ditches, perimeter slopes, all slopes steeper than 3' horizontal to 1' vertical (3 1) and all high quality water (HQW) zones shall be provided temporary or permanent stabilization with ground cover as soon as practicable but in any event within seven (7) calendar days from the last land -disturbing activity All other disturbed areas shall be provided temporary or permanent stabilization with ground cover as soon as practicable but in any event within fourteen (14) calendar days from the last land -disturbing activity 9 Flocculants will be used to address turbidity issues The pumps, tanks, hoses and inject systems will be checked for problems or turbid discharges daily 10 Refer to new NPDES rules regarding basin outlet structures and skimmers shall withdraw water from the surface SECTION 02920 SOIL EROSION AND SEDIMENTATION CONTROL GENERAL 1 1 Contractor shall take every reasonable precaution throughout construction to prevent the erosion of soil and the sedimentation of streams, lakes, reservoirs, other water impoundments, ground surfaces, or other property as required by State and Local regulations 12 The Contractor shall install all required silt fences, and construction entrances at the initiation of work, and have these measures reviewed and approved by the local permit authority prior to clearing and grading operations 13 The Contractor shall, within 21 days of suspension or completion of land disturbing activities, provide permanent protective covering for disturbed areas Temporary and permanent erosion control measures shall be coordinated to assure economical, effective, and continuous erosion and siltation control throughout the construction and post -construction period Use the specified seed for both temporary and permanent seeding 2 PRODUCTS 21 Asphalt for anchoring mulch shall be Type SS-1 Emulsion 22 Fertilizer shall be 10-10-10 grade or equivalent 23 Lime shall be dolomitic agricultural ground limestone containing not less than 10 percent magnesium oxide 24 Mulch shall be small gram straw, hay, wood chips, asphalt emulsion, jute or other suitable material free of undesirable weed seed 25 Phosphate shall be 20 percent superphosphate or equivalent 26 Seed shall be 20% carpet grass, 24% Bermuda, 20% turf Fescue, 10% Creeping Red Fescue, and 24% Annual Rye gram Bermuda seed shall be hulled for warm weather planting and unhulled for cool weather planting Purity of seed shall be a minimum of 98 percent and germination shall be a minimum of 85 percent 27 Sift fence shall consist of NCDOT Class A fabric supported by metal posts spaced not more than 6 feet on center The bottom of the fabric shall be buried a minimum of 6 inches 28 Gravel for check dams shall be #57 washed stone 29 Aggregate for construction entrance shall be #4 washed stone 210 Stone rip rap for check dams and erosion control shall be NCDOT Class A or B as shown 3 EXECUTION 31 General Take every practicable measure during construction or suspension to work to minimize erosion and siltation Measures should include good construction practices, temporary physical barriers to sediment travel, settling basins for new ditches, and establishment of vegetative cover 32 Construction Practices 3 2 1 Avoid dumping sod or sediment into any wetland or watercourse 3 2 2 Maintain an undisturbed vegetative buffer where possible between a natural watercourse and trenching and grading operations 3 2 3 Avoid equipment crossings of streams, creeks, and ditches where practicable 3 2 4 Grade all cut, fill and ditch slopes to minimum slope of 3 1, unless otherwise shown or directed 33 Temporary Physical Barriers are required where sedimentation on offsite property or excessive erosion is a problem 3 3 1 Mulch shall be used for temporary stabilization of areas subject to excessive erosion and for protection of seedbeds after planting where required 1 Apply grain straw and hay at a rate of 75 to 100 pounds per 1,000 square feet and wood chips at a rate of 500 pounds per 1,000 square feet Jute and mesh should be installed as per manufacturer's instructions 2 Asphalt emulsion for slope stabilization should be applied at a rate of 1,000 gallons per acre Asphalt emulsion used for anchoring straw should be applied at a rate of 150 gallons per ton of straw 3 3 2 Silt Fences shall be used at the base of slopes to restrict movement of sediment from the site Clean silt fence of accumulated sediment after each rainfall event or when it exceeds a depth of 0 5 feet above natural grade 3 3 3 Stone Check Dams, placed at the discharges of creeks, ditches, and swales, shall consist of Class A or Class B erosion control stone at minimum two feet high and three feet thick across the watercourse, with a one foot thick layer of gravel on upstream side Remove sediment if accumulated to a depth of 10 feet at upstream face 34 Vegetative Cover Establish and maintain permanent vegetative cover on all unpaved areas disturbed by the work 3 4 1 Preparation of Seedbed Areas to be seeded shall be scarified to a depth of 4 inches and until a firm, well pulverized, uniform seedbed is prepared Lime, phosphorous and fertilizer shall be applied during the scarification process in accordance with the following rates Lime 45 pounds per 1000 square feet Phosphorous 20 pounds per 1,000 square feet Fertilizer 17 pounds per 1000 square feet 342 Seeding Disturbed areas shall be seeded with 2 to 3 pounds per 1000 square feet of the specified seed mixture Seed shall be worked into the bed to a depth of 1/4 inch Regrade and seed eroded areas immediately 3 4 3 Mulch all areas immediately after seeding Mulch shall be applied and anchored as specified hereinbefore Reapply as necessary to retain cover until grass is established 35 Construction Entrance Provide an aggregate drive, 20 feet wide by 50 feet long by 6 inches thick at each entrance to the site used by construction vehicles, until such time as the permanent roadway is constructed Remove sod if accumulated to a depth greater than 0 5 inches 36 Maintenance The Owner and Contractor shall be responsible for maintaining all temporary and permanent erosion control measures Temporary structures shall be maintained until such time as vegetation is firmly established in the area protected by the structure Permanent streambank protection and grassed areas shall be maintained until completion of the project Areas that fail to show a suitable stand of grass or which are damaged by erosion shall be immediately repaired END OF SECTION 1127 Floral Parkway Suite 400 Wilmington, NC 28403 (910) 343-9653 (910) 343-9604 Fax John S Tunstall, PE May 22, 2012 Norris & Tunstall Consulting Engineers, P.C. Ms Jo Casmer NC DENR 1 Division of Water Quality Water Quality Section 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Re State Stormwater Permit Submittal Empire Distributors — Lot 8A New Hanover County, NC N&T Project No 12023 Dear Ms Casmer 1429 Ash -Little River Road Ash, NC 28420 (910) 287-5900 (910) 287-5902 Fax J Phillip Norris, PE Enclosed are two (2) sets of plans for the above referenced project, which include the drainage area plans, one (1) set of calculations, one (1) copy of the stormwater narrative, one (1) USGS map, one (1) copy of the soils 1 infiltration system report, one (1) copy of the deed, one (1) copy of the Articles of Organization, the original Division of Water Quality Stormwater Management Permit application, the original SW-401 Wet Detention Basin Supplement form, the original Wet Detention Basin Operation and Maintenance Agreement and a $505 00 check for the permit review fee Please review this information for approval and contact us with any questions or comments you may have Thank you for your assistance on this project Sincerely, NORRIS & TUNSTALL CONSULTING ENGINEERS, P J PhittrfS Norris, PN/neh 12023 05-22-12-s-sw-Itr Enclosures EC IV MAY 2 4 2012 BY - cc Mr Dyrc McLeod 1 Empire Distributors Mr Michael A Kahn 1 Empire Distributors NCBELS License C-3641 10,11Z4178 CO r Jennifer H MacNeish Register of Deeds New Hanover County, NC Electronically Recorded 2012 May 09 11 36 AM RE Excise Tax $380 00 Book 5639 Page 1541 Fee $26 00 Instrument Number 2012015418 Non -Standard Fee necelve MAY 2 4 1011 D BY NORTH CAROLINA GENERAL WARRANTY DEED Revenue Stamps S3aQM — Account No. Parcel Identifier No P rt of R01100-008-011- 04 Mail after recording to This instrument was prepared by. David G Martin Smith Moore Leatherwood LLP 300 North Third Street, Suite_301, Wilmington, NC 28401 LVtbRIg title examination) Brief description for the Index Lot 8A. Island Park THIS DEED made this day of April, 2012 by and between GRANTOR AUIOPARKAS9OMM OF WKMINGTON,LLCJ allorihCarnl6alimited liability company 4951 New Centre Drive Wilmington, North Carolina 28403 GRANTEE EMPIRE DISTRIBUTORS OF NORTH CAROLINA, INC., a Georgia corporation 3755 Atlanta Industrial Parkway Atlanta, Georgia 30331 The designation Grantor and Grantee as used herein shall include said parties, their heirs, successors, and assigns, and shall include singular, plural, masculine, feminine or neuter as required by context WITNESSETH, that the Grantor, for a valuable consideration paid by the Grantee, the receipt of which is hereby acknowledged, has and by these presents does grant, bargain, sell and convey unto the Grantee in fee simple, all that certain lot or parcel of land situated in New Hanover County, North Carolina and more particularly described as follows BEING ALL of Lot 8A, Island Park, containing approximately 165 acres, as shown on a plat thereof entitled "Island Park, Lot 8A,1 65 Acres +/-" which is recorded in Map Book WILM1-subnittedjelectronicall by "Myatt Early Harris Wheeler LLP" in compliance with North Carolina statutes governing recordable documents and the terms of the submitter agreement with the New Hanover county Register of Deeds. �, page 335 in the Office of the Register of Deeds of New Hanover County, North Carolina (the "Plat"), reference to which Plat is hereby made for a more complete description Together with and including, but without warranties of title from the Grantor, all rights associated with those instruments recorded in Book 2434, page 273 and Book 2666, page 770, New Hanover County Registry. Subject, however, to, ad valorem taxes not yet due and payable, all governmental land use statutes, ordinances and regulations, including, without limitation, zoning, subdivision and building regulations, and the additional permitted exceptions shown on the attached Exhibit A The property herefnabove described was acquired by Grantor by instrument recorded in Book 2408, page 855, New Hanover County Registry TO HAVE AND TO HOLD the aforesaid lot or parcel of land and all privileges and appurtenances thereto belonging to the Grantee in fee simple And the Grantor covenants with the Grantee, that Grantor is seized of die premises in fee simple, has the right to convey the same in fee simple, that title is marketable and free and clear of all encumbrances, and that Grantor will warrant and defend the title against the lawful claims of all persons whomsoever, except for the exceptions herein stated The property described herein O does ffi does not include the primary residence of the Grantor (SIGNATURE PAGE AND NOTARY ACKNOWLEDGMENT FOLLOWS) WTLMfNGTON46384 3 2 IN WITNESS WHEREOF, the Grantor has hereto caused this instrument to be executed by its duly authorized manager the day and year first above written GRANTOR: AUTOPARK ASSOCIATES OF WILMINOTON, LLC By. Name R Allen Rippy Title- Manager�tle"t,ew- STATE OF NORTH CAROLINA COUNTY OF NEW HANOVER I certify that the following person(s) personally appeared before me this day, each acknowledging to me that he or she voluntarily signed the foregoing document for the purpose stated therein and in the capacity indicated- R. Allen Rippy. Manager of AutogVk As&aciates of W_ Ilmtng_on. LLC Today's Date April J_]_ 2012 as name appears on seal] 'Pik, [Notary's printed name as name appears on seal] pugLlC � My commission expires `2 1 �� � ZC !`j _ �R /.6`` 1lli [Affix Notary Seal in Space Above] WILMINGTON 46384 3 3 Exiubit A Permitted Exceptions l , The lien of all taxes for the year 2012 and thereafter, which are not yet due and payable 2 Declaration of Restrictions, Covenants and Conditions of "Island Park," recorded in Book 1996, Page 667 with the Register of Deeds for New Hanover County, North Carolina, as amended by Amendments recorded at Book 2433, Page 44 and Book 2613, Page 457, aforesaid records 3 Building restriction lines, easements, and any other matters shown on map or plat recorded In Plat Book 50, Page 133, Book 36, Page 387, Book 35, Page 294, Book 39, Page 80, and Book 6, Page 90, all aforesaid records 4 Assignment of Declarant Rights recorded in Book 2433, Page 39, aforesaid records Mutual Access and Utility Easement recorded in Book 2434, Page 273, aforesaid records 6 Deed of Easement recorded in Book 2666, Page 770, aforesaid records 7 Easement or right-of-way in favor of Tidewater Power Company recorded in Book 342, Page 544, all aforesaid records 8 Easement(s) or rights) -of -way m favor of Carolina Power and Light Company recorded in Book 542, Page 120, Book 1055, Page 409, Book 1191, Page 1636, Book 1200, Page 1488, Book 2083, Page 177, Book 1250, Pages 79 and 80, and Book 844, Page 744, all aforesaid records 9 All matters disclosed by that certain ALTA/ACSM Survey of Island Park, Lot 8A, prepared by Michael Underwood and Associates, PA, and dated Apnl , 2012, WILMINGTON 46384 3 4 r-Sk" Completeness Review Checklist Project Name. �� _ �t�i3�F�tt� _ '� � fl Received Date dU (YIA-4 Ala Project Location Accepted Date Z. Rule(s) 01<008 Coastal 1:11995 Coastal Phase II (WiRO) Universal �1988 Coastal Type of Permit Sw> Mod or PR TExisting Permit # (Mod or PR) �PE Cert on File? 1 IY Density. HD or LD Type Commercial or Residential �NCG `Yogb�(�o OK?) Stream` Cla�s: �SA Map Off to SW8 Subdivided?. Paperwork Emailed Engineer on tr ISupplement(s) (1 original per BMP) BMP Type(s) "IUD 09M with correct/original signatures (1 original per BMP except [S/VFS and swales) rq<P-P-Iication with correct/original signatures Y rp or LLC Aut per SoS or letter Note to Reviewer: L �' 505 (within 6mo)`"n �bo�.St�icrn � 8f�7 ,�eo � • oils Report with SHWT ---304p f%oN ar% aiculations (signed/sealed) �No obvious errors 5 �c P Density includes common areas, etcd Restrictions, if subdivided n5tgned & Notarized Plans bilSe ts Grading Vicinity Map Legend Infiltration Soils Report. ttom Additional Information - Nermittea BUA (sf) DA (sf) PP (el) SHWT (el) Depth (ft) SA (sf) Details (roads, cul-de-sacs, curbs, sidewalks, BMPs, Buildings, etc) 'homw r Wetlands Delineated or No Wetlands Layout (proposed BUA dimensions) �DA MapsProject Boundariess Wet Pond Soils Report SHWT PP "Offsite OPE Cert for er Deed st for Master Permitted (Master) Proposed (Offsite) Lot # Lot # Matches Master sf sf