HomeMy WebLinkAboutSW8060834_HISTORICAL FILE_20061005STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW �L�QI)F'J9J�"i DOC TYPE El CURRENT PERMIT ❑ APPROVED PLANS �7 HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE /OOS YYYYMMDD 1 State Stormwater Management Systems Permit No SW8 060834 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Gerard J Skehan and Darske, LLC 4570 Long Beach Road Brunswick County FOR THE construction, operation and maintenance of an underground infiltration trench system in compliance with the provisions of 15A NCAC 2H 1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit This permit shall be effective from the date of issuance until October 5, 2016, and shall be subject to the following specified conditions and limitations I DESIGN STANDARDS 1 This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data 2 This stormwater system has been approved for the management of stormwater runoff as described in Section 16 on page 3 of this permit The stormwater control has been designed to handle the runoff from 32,620 square feet of impervious area (Trench A & B 8,491 sq ft each, Trench C 15,638 sq ft) The three trench systems must be operated with a 30' vegetated filter 3 The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans 4 All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans 5 The runoff from all built -upon area within the permitted drainage area of this project must be directed into the permitted stormwater control system Page 2 of 7 State Stormwater Management Systems Permit No SW8 060834 ` 6 The following design criteria have been provided in the infiltration trenches and must be maintained at design conditions Infiltration Trench Trench A Trench B Trench C a Drainage Area, acres 021 021 0 38 Onsite, ft 9,243 9,243 16,634 Off site, ft None None None b Total Impervious Surfaces, ft 8,491 8 491 15,638 c Design Storm, inches 1 0 1 0 1 0 d Trench Dimensions', L x W x H, ft 432 x 3 x 1 432 x 3 x 1 816 x 3 x 1 e Perforated PI a Diameter/Length' 10" 01432' L 10" 01432' L 10"0/816' L f Bottom Elevation, FMSL 24 C (97 0 per benchmark) 24 0 (97 0 per benchmark) 24 5 (97 5 per benchmark) Bypass Weir Elevation, FMSL 25 0 (98 0 per benchmark) 25 0 (98 0 per benchmark) 25 5 (98 5 per benchmark) h Permitted Storage Volume, ft 680 680 1,246 i Type of Soil Yaupon Silly Clay Yaupon Silty Day Yaupon Silty Clay Expected Infiltration Rate, inlhr 33 33 33 k Seasonal High Water -table, FMSL 22 0 (95 0 per benchmark) 22 0 (95 0 per benchmark 22 5 (95 5 per benchmark) I Time to Draw Down, hours 1 9 1 9 1 9 m Receiving Stream/River Basin Calf Gulley Creek/Cape Fear n Stream Index Number 18-88-9-3-3-1 o Classification of Water Body SC, Sw HQW "Based on a single run of pipe 11 SCHEDULE OF COMPLIANCE The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface 2 During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately 3 The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to a Semiannual scheduled inspections (every 6 months) b Sediment removal C Mowing and revegetation of slopes and the vegetated filter d Immediate repair of eroded areas e Maintenance of all slopes in accordance with approved plans and specifications f Debris removal and unclogging of bypass structure, filter media, flow spreader, catch basins, piping and vegetated filter g A clear access path to the bypass structure must be available at all times 4 Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ The records will indicate the date, activity, name of person performing the work and what actions were taken 5 The facilities shall be constructed as shown on the approved plans This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data Page 3 of 7 State Stormwater Management Systems Permit No SW8 060834 6 Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation Any deviations from the approved plans and specifications must be noted on the Certification A modification may be required for those deviations 7 If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility 8 Access to the stormwater facilities shall be maintained via appropriate easements at all times 9 The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below a Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc b Project name change c Transfer of ownership d Redesign or addition to the approved amount of built -upon area or to the drainage area e Further subdivision, acquisition, lease or sale of all or part of the project area The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought f Filling in, altering, or piping of any vegetative conveyance shown on the approved plan 10 The permittee shall submit final site layout and grading plans for any permitted future areas shown on the approved plans, prior to construction 11 A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction 12 The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made Ill GENERAL CONDITIONS This permit is not transferable except after notice to and approval by the Director In the event of a change of ownership, or a name change, the permittee must submit a formal permit transfer request to the Division of Water Quality, accompanied by a completed name/ownership change form, documentation from the parties involved, and other supporting materials as may be appropriate The approval of this request will be considered on its merits and may or may not be approved The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request Page 4 of 7 State Stormwater Management Systems Permit No SW8 060834 2 Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215 6A to 143-215 6C 3 The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal) having jurisdiction 4 In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems 5 The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility 6 The permit may be modified, revoked and reissued or terminated for cause The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition 7 Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual 8 Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit 9 The permittee shall notify the Division any name, ownership or mailing address changes within 30 days Permit issued this the 5th day of October 2006 NOR CAROLI ENVIRONMENTAL MANAGEMENT COMMISSION P for a Klimek, P E , Director Division of Water Quality By Authority of the Environmental Management Commission Page 5 of 7 E State Stormwater Management Systems Permit No SW8 060834 4570 Long Beach Road Stormwater Permit No SW8 060834 Brunswick Count Designer's Certification Page 1 of 2 1, , as a duly registered in the State of North Carolina, having been authorized to observe (periodically/ weekly/ full time) the construction of the protect, (Protect) for (Protect Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the protect construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications The checklist of items on page 2 of this form is included in the Certification Noted deviations from approved plans and specification Signature Registration Number Date SEAL Page 6of7 State Stormwater Management Systems Permit No SW8 060834 ! Page 2 of 2 Certification Requirements 1 The drainage area to the system contains approximately the permitted acreage 2 The drainage area to the system contains no more than the permitted amount of built -upon area .3 All the built -upon area associated with the protect is graded such that the runoff drains to the system 4 All roof drains are located such that the runoff is directed into the system 5 The bypass structure elevations are per the approved plan 6 The bypass structure is located per the approved plans 7 A Trash Rack is provided on the outlet/bypass structure 8 Ail slopes are grassed with permanent vegetation 9 Vegetated slopes are no steeper than 3 1 10 The inlets are located per the approved plans and do not cause short- circuiting of the system 11 The permitted amounts of surface area and/or volume have been provided 12 All required design depths are provided 13 All required parts of the system are provided 14 The required system dimensions are provided per the approved plans cc NCDENR-DWQ Regional Office Delaney Aycock, Brunswick County Building Inspections Jeff Phillips, Brunswick County Engineering Page 7 of 7 CONSULTING, PA 7332 Cotesworth Dnve Wilmington, NC 28405 (910) 619-9990 Fax (910) 401-1620 PLANNING - ENGINEERING - CONSTRUCTION MANAGEMENT September 5, 2006 Paul T Bartlett, PE NCDENR-DWQ 127 Cardinal Drive Ext Wilmington, NC 28405 RE Responses to August 28, 2006 Comments Project No SW8 060834 4570 Long Beach Road Mr Bartlett This letter is response to your comment letter dated August 28, 2006 (copy attached) I appreciate your timely comments and hope I have answered all questions in this letter For ease of reference I have numbered my responses in the same order as your check fist and the comments I have added the Bench Mark and the assumed elevation, per our phone conversation regarding the use of FMSL The drainage basin area of basin ` ' is 16,634sf u indicated, I have revised the calculations and the basin map an p ement form to reflect this number U-3/ The supplement forms for A and B have been corrected and are attached for your review /4 The plans have been corrected and are attached for your review t15 The supplement forms for A and B have been corrected and are attached for your review �6 The plans have been corrected and are attached for your review Please do not hastate to call if you have any addition questions Sincerely urs, JefferyA Roney Senior Designer Attached 2 - revised Plan Sheet C2 2 - Revised sheet 2 of SWU-101 form 2 - Revised basin information sheet 2 - Revised sheet 1 and 2 of SWU-107 form for Trench A, B and C 2 - Revised Drainage Basin Map 2 - Revised stormwater treatment worksheet ATA NCD�NR Nchh Carolina,�rtment'at mm�ranment and NaWrat Resources 127 Cardummt Dave, WAmmMmi NC 28405 (910) 79&7307' FAX (910) 350-2004 Request for Express Permit Review RILL -IN all lnfiornia#r"on below and CHECK required Permits) fAX or email to Camerorr:WeayeK& ncmail.net along with a narrative andyicinil�ap of fhe project location. Projects must be submitted by 9.00 A.M.of the review date, unless prior arramgements are made. PPLA 1CAN I Company PROJECT Name 5'70 LPOCA �a `F—vfiV PROJECT SYSTEM(S) TRIBUTARY TO, CA%-F �S �_ `11_ (STREAM NAME) i=v/A3 11 cT RIVER BASIN ENGINEERICONSULTANT Company S Addnass Z� �ji!5 j4;6tate W)LmrvG ias AXLrj_ County Phone, o _ 7' 1d F do of �Zo Emaii }7563�(r�vcl►' e State or Rational Environmental Policy Act (SEPA, NEPA) — EA or ElS Required ❑ Yes{ No STREAM ORIGIN Dete►minedon; # of stream calls, Stream Name ❑ STORMWATER ❑ Low Density ❑ High Density -Detention Pond ❑ High Densdy-Other Wetlands MUST be addressed below ❑ Low Denser -Curb & Gutter XHigh Density -Infiltration ❑ Off Site CWASTAL ❑ Exeavaton & Fill ❑ Bndges & Culverts ❑ Structures,informahon kANAGEMENT ❑ Upland Development ❑ Marina Development ❑ Urban Waterfront LAND QUAL 17Y ❑ Erosion"and Sedimentation Control Plan with acres to be disturbed_ WETLANDS (401) Wetlands on Property ❑ Yes�,No Isolated Wetlands on Property C7 yes 9 No Check all that ail a��lv Wetlands WIl Be Impacted ❑ Yes9 No, Wetland Impacts _Acre p� Wetlands Delineation has been completed ❑ Yes ❑ No ❑ Buffers Impacted Acres) l 1 USACOE Approval of Delrrreabon completed ❑ Yes ❑ No 404 Apphcabon in process wIUSACOE ❑Yes F]NoI Permit received from USAGE []Yes F]No 401 Application required []Yes ❑ No if Yes, ❑ Regular ❑ Expri ss Additional fees, not to exceed SD% of the virginal Express Review permit application fee, may be charged for subsequent reviews due to the insufficiency of the pemut appllcatons. t For DENR use only SUBMITTAL DATES- l vee Split for multiple permits. SW $ CAMA LQS S 401 $ Total Fee Amount $ INFILTRATION SITE VISIT REQUEST Name of the Project. 5-7(n 1,60,q 3a6c �/- 3�)-p Location (attach a clear vicinity map)- nc- SR number community, etc Directions from the nearest major intersection. VJ1 Z i.� t o i 2-T - S ,50 )1 va- cued W -? Z. k' 1 IS M > D � Owner/Applicant Name Consultant Name WI C< Consultant ContacHnformatiori• 10,' 611 ~ t`lo qa) -16z Phand, fax, 0"d, etc. $Ec. pF r p�C M.E�- 41 42 #1 #4 #5 #6 #7 #8 Existing ground elev @basrn/trench= SHVVT elev = SHWT plus 2' (max bottom elev )= DateJT,ime of Sods Investigation Summary/Comments: All proposed infiltration areas and,exsstmg, active ublrty Imes located within the proposed basmttrench must be marked and flagged if these`areas are not flagged, the Soils Scaentrst reserves the right to decline`to do the investigation If the proposed infiltration system will b0ocated'in an area of,extsting pavement and there is no opera area'nearby, equipment, capable of breaking through the impervious layer, must be`pravrded The soils inve*abon does not take the place�of a soils report prepared by °an appropnate professional The So#Is,Sb entistiwdl'only�venfy the soil conddi6ns that are reported in the;Sods Report,,and make a,determination as to the surtabrlrty,of the site toy meet the infiltration design requirements under NCAC, 2H 1000, and'assdmes no liability should the system fail 'Checklist for Express Permitting For Offsde projects- E] Has,the Designer's Certrficatro6 for the offsrte system been submitted? Have the'deeci restnctrons been recorded and submitted? For InflVation Projects. `j Has Vincent been to th& site for the soils? For Ail rojects- Is,the project low density, curb outlet, wet pond, tratro , or offsrte? If there ire wetland issues, has Wthe 401 /404 permit been issued, or is it also going'Express? No L)C-T�-,PS <Dfi' z�,?c if the,applrcant is a corporate entity, is the entity regrstered'wrth the Secretary of SWtO c. ti e,q Look,up,the offsite system on BIMS to see if these events have occurred You may also want to pull the file to see rf theCdocumentsinei�e,recerved but not logged onto SIMS, Call Vincent and ask hrrn: Unda may have a paper record of the site visit in her office NCDER STORMWATER CALCULATIONS AND SUPPORTING DATA 4570 LONG BEACH ROAD Oak Island, NC Brunswick County June 23, 2006 Prepared for Darske, LLC 42 Yaupon Way Oak Island, NC 28465 Prepared by JBS Consulting 7332 Cotesworth Dr Wilmington, NC 28405 UO3ALUM 4570 LONG BEACH ROAD Oak Island, NC Brunswick County June 23, 2006 Table of Contents DESIGN NARRATIVE Existing Site Proposed Improvements Post Developed Basin Maps 1" Treatment Volume Calculations Stream Classification Geotechnical Report by ECS 4570 LONG BEACH ROAD Oak Island, NC Brunswick County June 23, 2006 DESIGN NARRATIVE Existing Site Darske, LLC is proposing the development of a 1 03 acre tract of land, in Brunswick County The proposed project site is located at 4570 Long Beach Road (NC 133), just to the north of North Hampton Drive The site is currently undeveloped Figure 1 - USGS The Brunswick County SCS Sod Survey indicates that the property's soil is Yaupon silty clay loam (YaB) Yaupon silty clay loam is a poorly drained to moderately well drained clayey soil Surface runoff is slow and permeability is slow Engineering Consulting Services, LTD preformed a field geotechnical investigation of the sites There report indicates that the soils on the site have an infiltration rate of 3 3 to 4 2 inches per hour at the tested depth of 8" inches below grade and a seasonal high water table at a depth of 24 to 30 inches below grade A copy of their report is included in this report No wetlands have been identified on the property The property is located in a basin that drains to the Calf Gully Creek, within the Lumber River Basin and is not classified Proposed Improvements The proposed development will consist of 4 retail/office units, paved access drives and parking, the necessary utilities services will be provided from the existing infrastructure and a stormwater management system will provide treatment and pre/post attenuation The site will be accessed from Long Beach Road A total of 40 parking spaces are provided to serve the development The proposed impervious areas will are made up of 10,000 sq ft of buildings, 22,754 sq ft of asphalt and 1,850 sq ft of concrete paved areas, making the total built upon area 33,306 sq ft , 77 1% of the 1 03 acre total property area NCDENR requires that a BMP be provided to remove stormwater pollutants (treatment) from the first 1" runoff In order to meet the treatment and attenuation requirement, the project's stormwater runoff will be captured in infiltration trenches The trench bottom will be a minimum of 2' above the seasonal high water table A bypass overflow structure is provided to discharge excess stormwater The infiltration trenches will draw down in 2 to 5 days ' i r ` - WS Ciroliioas, LLP„ i a I F ,r+11 Geotecht�iW}• ConeirnctiohMatmials O Euviroz6iental �■' t r s 4<8 1 I jCAROYINIA"' IIEp Six iF 1[ ji1 �WS [ f ,1 i 13 i i I I `� EMI 1 z 'xd x5 J r ,Tum 6, 2Qo6l, �; r r 1r15 1 a•1iL 1 Lla4 M�i I �i 7332 Cateaworth llinval , f Wihiun&n,,N� Camliaaa 28405 ' f Re 3�fi1tradon Evalua#zon[ I,1 4570 13'ca& R&S , Oik 7 bm4 North Car alm r BCS1 Lid Project No 22.12208 a, ? t 4 S f stir s i e 1 f R n r i �f If 5 113 DearN . Sed&q ECS Caroimas, LLP' ( ) xeceutly,, conducted an infiltir�ion evaluafm for the proposodt I locationat praposod,she`at 4570 Longeach Road m,Oak Island, North, Caroht . `'This' 1 �th{e� lefter, 94A ii�Kl��� i 1.S.fii1 �Olt of our MVftf gEdx0M x 1 + 4 [r F FieldInve0gaioIi7 /x�,,, TT e l 'r�/�/�� ��a �.—���7.=,,},,,,7 ,�y� r, y,�j,� r ,,SyIn�,,f,,,�y If``�,,�_��.,[a I \.Ill IA� �, 2006, BCS � �'an regp�rS�ion ;ol 4[ a x�':f� soil � ground wow 1 I !I { ! 4 p 31 I f ; [ conditions 3at two requosW liacatidba sho m A thet'atta ad Sate i}ia�un. The purpose of this, exploration was to obtaiu subsurface 3if (xn of the soitalnhty of the in -place soils,fb r -t e proposed InfiliratiOn a� 9 •i Y13�1INRyt4�V 1 1/�7l�ltWi1Ll i ��M�iw1 I advancing <two hand "huger, borings into the esistm ,g�{nd �e at he r6 �estc4 teat locations We mauaily t"classified the subsurface sous and obW ed reprase�ve samples' of each sozl y* Herod. We�'alsoerecorded. the grc and water level observed at the tune�af the � ,Mt{LlVhad,b �I �(�}�/y� p} xl �qf Ty���}/�(.�n� �/� /iy.��t��.{s ���p� p /�'TL. •}gyp + +V ge ! ill i�+V ' It ailllVLy'h+Ti+I LL i�`y � pmmdea a � V+ th 1 5 9 subsurface conditions encountered at ea6 bud aLga boruig location. } Y 6 Gro� water was not e3ncotmteaefi dvnng our eiplomban at the requested °test locations up to a ' <� depth of 72 inches Wow the emmmg,grade elevation. The 'se"amd #ugh ground water lovd ,i (S11WL) at location, 0 was estimated to ,be at a & pth of 30 inches The seasonal, hih ground water level (WL) at lociitton'#Zwia estimated to beat a depth of 24 inch 7 t t i1 1 I{ y 1 [ i P it 3 JJW+N Ml Y l� �i+i:iisl4/jl y 5114 F, I i r} We have CQTldt�Ct9d lni71t1�l�io� te9ta neti1" ow rate 0 ' ! fortlie'sub `surface moils: 'The infiltration tests" c�tidulcted agpraximataly 8 inches'below the '' � I ';` �' , , I` 1 = r a x q l 4 I3 fl �31 1 rf I� 1 7211 'C]gdenBusiness Park • Siuta 201 • W*nington, NC 28411 � • (910) 686-9114 • Fax (910) 686-9666 ' sr It 63 t Iv It I s In$ltrsttc6 Eviduddon t I 4570 Lang Baarl Reed ' Osk Is an4 Nmfh C�rOUDa 8CB Project Wo. 22,122,08 6 ` ` Fie1d,T0vt RwWt8 I at 1 ! i S ` i j ` I, e { I t x i4 h i F 9 4° }4 ] P fi 9 I 'Y i er t� 11 i t ` ° l E S i 1 E p At location M.1*e'MfiltrHbon,4lted pefarm0d at 8 nnahues m Mown 91ty fine SAND and. � "catod an mfiltratiibn zoo of O., 07 mohes per minute (41 in"bb" s per hour)At location they mfikmuon test was performed at 8 mches in brown silty fine SAND at d mdioated an strata m rate of 0.06 mcbrs per mi nate (33 inches per hour) Infltrntion+rates may var}' wren dw pr`opo's'od' site,due to pasm"ble changm in subgmfice i �t , i " S y , If you have any qucatidna'regarding thisro please contact ua at (910) b86-91114. t i i E i 4, t 1 t E I 1r Ei I = tl s is ECS CAROM" LLP I I / � r 4 f Winslow E Going, R1 , Wand°M. Sobh, P IL i I piOjeCtM met y 4 PTMCpallEnglAef, NC I,Iemse N6 22983 ' IIo, 1 3 I�. Il�w Da,, I f f BonnglLo m&m Evaluabc 1 E 4 t cl tI k r c 6 s ` _ Iz s I� it 4 t ,y � � 31 , i t ♦� 1 I }- t r I S t qa s 5 r } t ° l � ✓ a 1 ti r r f I r t t f `fi i 401 lK �.-....,.� r _ ^ s bENOTES APPROMWE WCAT61N = _ _ W OF INFILTRATION TEST RMLTRATION TEST REftRMCE' = - - LOCATION MAP SITE - MAP PROVIDED -BY JWBS - - _ - = 4570 L{jNG BEACH ROAD - - NOT TQ SCALE - r CONSIILTMG: PA_ LLP e -OAK -MIND, NORM --CAROLINA 9M 4 A 1 u 3 r i 4 s � q i iq Si t q r a � 4a Infiltration Evaluation i i 4570 Long Beach k66d Oak, Islaild, Norffi'Caiah a ECS,PiojectAio.i2i12208 a i t 4 i 1 V June 6, 2006 " i t s G i t t � 4 t LoC-Lftori D, e 1 Sod Descri�t�on � 4 a #1 t 0-72" 1; ` 'i Brown silty fine SAND' t a SeasooniW High Water4T ble was estimated toi& 36iiiches below the existing�grade ' fi 1 4 4 t elevation. I s i t Infiltration Rate: 0.07,inches par minRute (4:2 inches per hour) , " i 5 z 41S a a Test was conducted at Unches below existingagrade elevation r l t 4 3 � Ground Ywateiwas not encountered up to ,72 inches below the existing grade elevation r a • a Ft � 1 Laoa n � foil` D ivtion ; #2 t t ` 0-72" 'Bi6wh silty fine SAITm i 4 i r Seasonal High Wa%i Table was estimated to bo 24'inches below the existing grade elevation. n 1 Infiltration Rate: 0.06 inches pec minute (3.3,mches per hour) Test was tconciuctedii at 8 inches Below existing giade'elevatian w i Ground *ater was not' encountered. up to,72 mn 6i below the existit g grade elevation. , ➢ A 4 t ! iF a , r` F s i � t t Is � a t s♦ fl i r t t e 1 � 5 SS 5 x � it tS t a e9 t V i r i i 3 i t s { Mai 0 i t ! s � i l S t t i i � V i 1 � t t 1 t 5 Md p avow IC i iii1 oL9* oas vw xm III AIM 0101J ow lowm Iw bl� I y%/u 6 Xec et' /pv,l Z State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may be photocopied for use as an original I. GENERAL INFORMATION: Applicant's name (specify the name of the corporation, individual, etc who owns the project) Darske, LLC 2 Print Owners/Signing Official's name and title (the person legally responsible for facility and compliance) Gerard j Skehan, Manager 3 Mailing Address for person listed in Item 2 above 42 Yaupon Way City Oak Island State NC Zip 28465 Telephone Number (910)278-9084 4 Project Name (subdivision, facility, or establishment name -should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc ) 4570 Lone; Beach Road 5 Location of Project (street address) 4570 Long Beach Road ^^ City Oak Island County Brunswick 6 Directions to project (from nearest major Intersection) The project Is located at 4570 Long Beach Road In Oak Island 7 Latitude 033056'28 93"N Longitude 078103'29 54"W 8 Contact person who can answer questions about the project Name Brad Sedgwick,PE -- Telephone Number II. PERMIT INFORMATION: 1 Specify whether project is (check one) X New Renewal of project _ (910) 619-9990 Modification Form 4%'UJI1-1AT llpmInn Z 00 parrs I nfd A 0 (9/6 lc)&" pec6'Y 1�e"/ � _tq s ct) 0 C/��Uc 5 f- 2 If this application is being submitted as the result of a renewal or modification to an existing permit, list the existing permit number and its issue date (if known) 3 Specify the type of project (check one) Low Density X Htgh Density Redevelop _General Permit Other 4 Additional Project Requirements (check applicable blanks) CAMA Major X Sediment/Erosion Control 404/401 Permit _NPDES Stormwater Information on required state permits can be obtained by contacting the Customer Service Center at 1-877-623-6748 M. PROTECT INFORMATION l In the space provided below, summarize how stormwater will be treated Also attach a detailed narrative (one to two pages) describing stormwater management for the project Multiple Under ound Infiltration Trenches 2 Stormwater runoff from this project dram to the „tom 1. rr River basin 3 Total Project Area 1 033 Acres 4 Project Built Upon Area 725 % 5 How many drainage areas does the project have? 3 6 Complete the following information for each drainage area If there are more than two drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below Basin Information Total Drainage Basin Drama a Basins A, B & C Stream Name Calf Gully Creek —Receiving Stream Class See attached sheet —Receiving Drainage Area 1 033 ac Existing Impervious* Area Proposed Impervious* Area 0 749 ac % Impervious* Area total 72 5% Impervious* Surface Area Drainage Basin Drainage Basin On -site Building 10,000 0 sf On -site Asphalt Road 20,836 0 sf See attached sheet On -site Sidewalks 1,784 0 sf Other on-SLte Off site Total 32,620 0 sf * Impervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas, sidewalks, gravel areas, etc It) - Form SWU-101 Version 3 99 Page ,Zof4 Basin Information Drama a Area "A" Dramase Area "B" Drainage Area "C" - Receiving Stream Name Calf Gully Creek Calf Gully Creek Calf Gully Creek Receiving Stream Class G' 7�i2 10 Drainage Area 0 21 ac 0 1 ac 1 0 38 ac Existing Impervious* Area Proposed Impervious* Area 0 19 ac 0 19 ac 0 36 ac % Impervious* Area (total) 90 5% 90 5% 94 7% Impervious* Surface Area Dratna a Basm Drama a Basm Drama a Basin - On -site Concrete 392 sf 392 sf 1000 sf On -site Asphalt Road/Parking 5099 sf 5099 sf 10638 sf On -site Building_3000 sf 3000 sf 4000 sf Other on -site Off site Total 8491 sf 8491 sf 15638 sf n� h v— 7 How was the off -site impervious area listed denved9 NIA IV DEED RESTRICTIONS AND PROTECTIVE COVENANTS The following italicized deed restrictions and protective covenants are required to be recorded for all subdivisions, out parcels and future development prior to sale of any lot If lot sizes vary significantly, a table listing each lot number, size and the allowable built upon area for each lot must be provided as an attachment I The following covenants are intended to ensure ongoing compliance with state management permit number as issued by the Division of Water Quality These covenants my not be changed or deleted without the consent of the State l No more than square feet of any lot shall be covered by structures or impervious materials Impervious materials include asphalt, gravel, concrete, brick, stone, slate or similar material but do not include wood decking or the water surface of swimming pools 3 Swales shall not be f lled in, piped, or altered except as necessary to provide driveway crossings 4 Built -upon area in excess of the permitted amount requires a state stormwater management permit modification prior to construction 5 All permitted runoff from out parcels or future development shall be directed into the permitted stormwater control system These connections to the stormwater control system shall be performed in a manner that maintains the integrity and performance of the system as permitted By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the applicable item required above, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot V SUPPLEMENT FORMS The applicable state stormwater management permit supplement form (s) listed below must be submitted for each BMP specified for this project Contact the Stormwater and General Permits Unit at (919) 733-5083 for the status and availability of these forms Form SWU-102 Wet Detention Basin Supplement Form SWU-103 Infiltration Basin Supplement Form SWU-104 Low Density Supplement Form SWU-105 Curb Outict System Supplement Form SWU-106 Off -Site System Supplement Form SWU-107 Underground Infiltration Trench Supplement Form SWU-108 Neuse River Basin Supplement Form SWU-109 Innovative Best Management Practice Supplement Pnrm qWT f-i 0 1 Vi-rcinn I QQ PanP Z of a VI. SUBMITTAL REQUIREMENTS Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ). A complete package includes all of the items listed below The complete application package should be submitted to the appropriate DWQ Regional Office. 1 Please indicate that you have provided the following required information by initialing in the space provided next to each item • Original and one cove of the Stormwater Management Permit Application Form • One coov of the annhoable Supplement Form(s) for each BMP • Permit asplication processine fee of $420 (savable to NCDENR) • Detailed narrative description of stormwater treatment/manaeement • Two conies of clans and specifications includins - Development/Project name - Engineer and firm - Legend - North arrow - Scale - Revision number & date - Mean high water line - Dimensioned property/project boundary - Location map with named streets or NCSR numbers - Original contours, proposed contours, spot elevations, finished floor elevations - Details of roads, drainage features, collection systems, and stormwater control measures - Wetlands delineated, or a note on plans that none exist - Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations - Drainage areas delineated - Vegetated buffers (where required) VI AGENT AUTHORIZATION If you wish to designate authority to another individual or firm so that they may provide information on your behalf, please complete this section Designated agent (individual or firm) JBS Consulting, PA_ Attention Brad Sedgwick, PE Mailing Address 7332 Cotesworth Dr City Wilmington State NC Phone (910) 619-9990 Fax 910 0 — o�.��20 VIII APPLICANT'S CERTIFICATION Zip 28405 1, (print or type name of person listed in Genera! Information, item 2) Gerard J Skehan, Manager certify that the information included on this permit application form is, to the best of my knowledge, correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective cove is will be recorded, and that the proposed project complies with the requirements of 15A NCAC 000 �-� Signature Date a Pnrrn QUIT 1_11)1 VPreinn14Q PnaPdofd `EV- //�� Permit NoJ 4& 6&e131 C II(to be provided by DWQ) State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM UNDERGROUND INFILTRATION TRENCH SUPPLEMENT This form may be pholocopled for use as an original DWO Stormwater Management Plan Review A complete stormwater management plan submittal includes a stormwater management permit application, an underground infiltration trench supplement for each system, design calculations, and plans and specifications showing all stormwater conveyances and system details I. PROJECT INFORMATION Project Name 4570 Long Beach Road Contact Person Brad Sedgwick . PE Phone Number _ (910) 619-9990 For projects with multiple infiltration systems, a supplement form must be completed for each system This worksheet applies to Trench A in Drainage Area A (from plans) (from Form SWU-101) H. DESIGN INFORMATION (attach supporting calculations/documentation): Sods Report Summary (based upon an actual field investigation and soil borings) Soil Type Yaupon silty clay Infiltration Rate 33 SHWT Elevation 95 J Trench Design Parameters Design Volume 6588 Design Storm l Drawdown Time 05 Perforated Pipe Size 10 Perforated Pipe Length 432 No Observation Wells 2 Stone Type (if used) #57 Stone Void Ratio 40% Trench Elevations (in feet mean sea level) Bottom Elevation 97 Storage/Overflow Elevation 98 ii'lQ j4 6 m/hr ee C 2 t fmsl (Seasonal High Water Table elevation) 1'zc ',N'ec� s ire IJt,I. w►-k �f a5J(4..µ-W'? 'J e61"- inch event (15 inch event for SA waters, I inch event for others) days inch diameter ft (may be required on a case -by -case basis) � frrisl F'e,'J"'e'v �� fmsl Form SWU-107 Rev 3 99 Page 1 of 4 °) 4 106 %� /Oev . 2, Fc,) 9 06a 6311 Trench Dimensions Height 1 ft Length 432 ft Width 3 ft Volume Provided 59-r cu ft III. REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the Stormwater Best Management Practices manual (N C Department of Environment, Health and Natural Resources, November 1995) and Administrative Code Section 15 A NCAC 2H 1008 Initial in the space provided to indicate that the following design requirements have been met and supporting documentation is attached If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below Attach Justification if a requirement has not been met Applicants Initials a b c d f g h 0 System is located 50 feet from class SA waters and 30 feet from other surface waters System is located at least 100 feet from water supply wells Bottom of system is at least 2 feet above the seasonal high water table Bottom of the system is 3 feet above any bedrock or impervious soil horizon Off-line system, runoff in excess of the design volume bypasses the system (bypass detail provided) System is designed to draw down the design storage volume to the proposed bottom elevation under seasonal high water conditions within five days based upon infiltration through the bottom only (a hydrogeologic evaluation may be required) Soils have a minimum hydraulic conductivity of 0 52 inches per hour System is not sited on or in fill material or DWQ approval has been obtained Plans ensure that the installed system will meet design specifications (constructed or restored) upon initial operation once the project is complete and the entire drainage area is stabilized a System is sized to take into account the runoff at the ultimate built -out potential from all surfaces draining to the system, including any off -site drainage System is located in a recorded drainage easement for the purposes of operation and maintenance and has recorded access easements to the nearest public right-of-way System captures and infiltrates the runoff from the first 1 0-inch of rainfall (1 5 inch event for areas draining to SA waters) Drainage area for the device is less than 5 acres A pretreatment device (filter strip, grassed swale, sediment trap, etc ) is provided Trench bottom is covered with a layer of clean sand to an average depth of 4 inches p Sides of the infiltration trench are lined with geotextile fabric q Rock used is free of fines (washed stone) and has a large void ratio r Side to bottom area ratio is less than 4 1 s Observation well(s) are provided (case -by -case basis) Form S U-1o7 Rev 3 99 Page 2 of 4 %] t. Vegetated filter is provided for overflow (50 feet for SA waters, 30 feet for other waters) and detail is shown on plans u A benchmark for checking sediment accumulation is provided Iv. UNDERGROUND INFILTRATION TRENCH OPERATION AND MAINTENANCE AGREEMENT 1 After every runofproducmg rainfall event and at least monthly inspect the bypass/overflow structure for blockage and deterioration and the infiltration system for erosion, trash accumulation, grass cover, and general condition 2 Repair eroded areas immediately, re -seed as necessary to maintain adequate vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash and blockages as needed to maintain system performance 3 Remove accumulated sediment annually or when depth is reduced to 75% of the original design depth Restore depth to original design depth without over -excavating Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. 4 The water level in any monitoring wells will be recorded after a l-inch rainfall event and at least once a month Chronic high water table elevations (within 1 foot of the bottom of the system for a period of three months) shall be reported to DWQ immediately 5 If DWQ determines that the system is failing, the system will immediately be repaired or replaced to original design specifications If the system cannot be repaired to perform its design function, other stormwater control devices as allowed by NCAC 2H 1000 must be designed, approved and constricted 5 Remove accumulated sediment from the mfiltration system annually or when depth m the unit is reduced to 75% of the original design depth. The system shall be restored to the original design depth without over excavating Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed. Removed sediment shall be disposed of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality (i.e stockpilmg near a stormwater treatment device or stream, etc.) A benchmark shall be established in the infiltration system. The benchmark will document the original design depth so that accurate sediment accumulation readings can be taken The measunng device used to determine the depth at the benchmark shall be such that it will give an accurate depth reading and not readily penetrate mto accumulated sediments When the depth at the benchmark reads 2.5" the accumulated sediment shale be removed from the system. Form SWU-107 Rev 3 99 Page 3 of 4 i acknowledge and agree by my signature below that I am responsible for malnimng the StomwateT MijeCtlO,ft system In accordance with the six maintenance procedures listed above I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party Print Name and Tide _ Gerard J Skeban, Manager Address n Phone- Stgnatu Note The legally responsible party should not be a homeowners association unless more than 50% of the lots have been sold and a resident of the subdivision has been named the president p eQ , a Notary Public for the State ofNA r Cercn II M." , County of tom_, do hereby certify that . _ e,/clrc� --_I S-kc6a„n__personally appeared before me this .21 day of J 0 j,,e 2uQ4 and acknowledge the due execution of the forgoing infiltration basin maintenance requirements Witness my hand and official seal, Siittiof., �SNN R 000i10 Ls'e�,.a�� 0 a +y �TARY m IC �' 2 My commission expires Form SWU-107 Rev 3 99 Page 4 of 4 Q Permit No 37,3 �QU 5`1- (to be provided by DWQ) State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM UNDERGROUND INFILTRATION TRENCH SUPPLEMENT This farm may be photocopied for use as an original D WO Stormwater Management Plan Review A complete stormwater management plan submittal includes a stormwater management permit application, an underground infiltration trench supplement for each system, design calculations, and plans and specifications showing all stormwater conveyances and system details I PROJECT INFORMATION Project Name 4570 Long Beach Road Contact Person Brad Sedgwick, PE Phone Number (910) 61.9-9990 For projects with multiple infiltration systems, a supplement form must be completed for each system This worksheet applies to Trench B in Drainage Area B _ (from plans) (from Form SWU-101) H. DESIGN INFORMATION (attach supporting calculations/documentation): Soils Report Summary (based upon an actual field investigation and soil borings) Soil Type Yaupon silty clay Infiltration Rate 33 SHWT Elevation 95 Trench Design Parameters Design Volume 6588 Design Storm I Drawdown Time 05 Perforated Pipe Size 10 Perforated Pipe Length 432 No Observation Wells 2 Stone Type (if used) #57 Stone Void Ratio 40% Trench Elevations (Infeet mean sea level) Bottom Elevation 97 Storage/Overflow Elevation 98 / M 1014 c i n/hr lv"Y e G �i fmsl (Seasonal High Water Table elevation) s`r` Of'ur� Gf�Gktir� C� c f '755!t(R-0ef 7 � inch event (15 inch event for SA waters, 1 inch event for others ` days inch diameter ft (may be required on a case -by -case basis) fmsl fins I 4z��"a r �41C u I � 14 ' �(F �� r Form SWU-107 Rev 3 99 Page 1 of 4 �jl16i, 4ejliet�� 2- Trench Dimensions Height 1 ft Width 3 ft M. REQUIRED ITEMS CHECKLIST Length Volume Provided 432 ft ,659-$ cu ft The following checklist outlines design requirements per the Stormwater Best Management Practices manual (N C Department of Environment, Health and Natural Resources, November 1995) and Administrative Code Section 15 A NCAC 2H 1008 Initial in the space provided to indicate that the following design requirements have been met and supporting documentation is attached If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below Attach justification if a requirement has not been met Applicants Initials b a System is located 50 feet from class SA waters and 30 feet from other surface waters b System is located at least 100 feet from water supply wells c Bottom of system is at least 2 feet above the seasonal high water table d Bottom of the system is 3 feet above any bedrock or impervious soil horizon e .>� Off-line system, runoff in excess of the design volume bypasses the system (bypass detail provided) f System is designed to draw down the design storage volume to the proposed bottom elevation under seasonal high water conditions within five days based upon infiltration bottom through the only (a hydrogeologic evaluation may be required) Q,2 g I Soils have a minimum hydraulic conductivity of 0 52 inches per hour L h System is not sited on or in fill material or DWQ approval has been obtained i Plans ensure that the installed system will meet design specifications (constructed or nn J restored) upon initial operation once the project is complete and the entire drainage area is stabilized n j System is sized to take into account the runoff at the ultimate built -out potential from all �! Cr surfaces draining to the system, including any off -site drainage k System is located in a recorded drainage easement for the purposes of operation and maintenance and has recorded access easements to the nearest public right-of-way I System captures and infiltrates the runoff from the first 1 0-inch of rainfall (1 5 inch event for areas draining to SA waters) m Drainage area for the device is less than 5 acres n A pretreatment device (filter strip, grassed swale, sediment trap, etc ) is provided o Trench bottom is covered with a layer of clean sand to an average depth of 4 inches r� p Sides of the infiltration trench are lined with geotextile fabric q Rock used is Gee of fines (washed stone) and has a large void ratio VL r Side to bottom area ratio is less than 4 1 s Observation well(s) are provided (case -by -case basis) Form SWU-107 Rev 3 99 page 2 of 4 a_z_ t Vegetated filter is provided for overflow (50 feet for SA waters, 30 feet for other waters) and detail is shown on plans u A benchmark for checking sediment accumulation is provided W. UNDERGROUND INFILTRATION TRENCH OPERATION AND MAINTENANCE AGREEMENT I After every runoff producing rainfall event and at least monthly inspect the bypass/overflow structure for blockage and deterioration and the infiltration system for erosion, trash accumulation, grass cover, and general condition 2 Repair eroded areas immediately, re -seed as necessary to maintain adequate vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash and blockages as needed to maintain system performance Remove accumulated sediment annually or when depth is reduced to 75% of the original design depth Restore depth to original design depth without over -excavating Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed 4 4 The water level in any monitoring wells will be recorded after a 1-inch rainfall event and at least once a month Chronic high water table elevations (within 1 foot of the bottom of the system for a period of three months) shall be reported to DWQ immediately 5 If DWQ determines that the system is failing, the system will immediately be repaired or replaced to original design specifications If the system cannot be repaired to perform its design function, other stormwater control devices as allowed by NCAC 2H 1000 must be designed, approved and constructed 6 Remove accumulated sediment from the infiltration system annually or when depth in the unit is reduced to 75% of the original design depth The system shall be restored to the original design depth without over excavating Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed Removed sediment shall be disposed of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality (i e stockpiling near a stormwater treatment device or stream, etc ) A benchmark shall be established in the infiltration system The benchmark will document the original design depth so that accurate sediment accumulation readings can be taken The measuring device used to determine the depth at the benchmark shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments When the depth at the benchmark reads 2.5" , the accumulated sediment shall be removed from the system. Form SWU-107 Rev 3 99 Page 3 of 4 I acknowledge and agree by my signature below that I am responsible for maintaining the storrnwater collection system in accordance with the six maintenance procedures listed above I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party Print Name and Title Gerard J Skehan, Manager Address 4 1 1 ^ /' Note The legally responsible parry should not be a homeowners association unless more than 50% of the lots have been sold and a resident of the subdivision has been named the president 20 we- � , a Notary Public for the State of i.�w �`, ��� 1� v�County of do hereby certify that eret,rR tiT- eke",,, personally appeared before me this a:2 day of Z-o we . �c , and acknowledge the due execution of the forgoing infiltration basin maintenance requirements Witness my hand and official seal, ,,�,�11411i►i,���� - QQ- Np`ARY U ` 2z PUBLIC ZE ON SEAL My commission expires d - 7"�' t f �L o 0 y G. 09-Za � '"-'r4AVOiteP,,`0% Form SWU-107 Rev 3 99 Page 4 of 4 C) l�O� he'Wre" 1-7- Permit No -red9 a6 d (to be provided by DWQ) State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM UNDERGROUND INFILTRATION TRENCH SUPPLEMENT This form may be photocopied for use as an original DWO Stormwater Malta ement Plan Review. A complete stormwater management plan submittal includes a stormwater management permit application, an underground infiltration trench supplement for each system, design calculations, and plans and specifications showing all stormwater conveyances and system details I. PROJECT INFORMATION Project Name 4570 Long Beach Road Contact Person _ Brad Sedi wick PE Phone Number (910) 619-9990 For projects with multiple infiltration systems, a supplement form must be completed for each system This worksheet applies to Trench C in Drainage Area C (from plans) (from Form SWU-101) 11. DESIGN INFORMATION (attach supporting calculations/documentation) Soils Report Summary (based upon an actual field investigation and soil boringv) 'o-6 /a/�-%G Soil Type Yaupon silty clay Infiltration Rate 33 SHWT Elevation 95 5 Trench Design Parameters Design Volume 1245 1 Design Storm I Drawdown Time 05 Perforated Pipe Size 10 Perforated Pipe Length 816 No Observation Wells 2 Stone Type (if used) #57 Stone Void Ratio 40% Trench Elevations (in feet mean sea level) Bottom Elevation 975 Storage/Overflow Elevation 995 fmsl (Seasonal High Water Table elevation 2j'1�ctiL�r inch event (15 inch event for SA waters, I inch event for others) days inch diameter ft (may be required on a case -by -case basis) fmsl D�F " Form SWU-107 Rev 3 99 Page 1 of 4 /b /o ff'-- Zee V Trench Dimensions Height 1 ft Length 816 ft Width 3 ft Volume Provided 1246 2 cu ft III REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the Stormwater Best Management Practices manual (N C Department of Environment, Health and Natural Resources, November 1995) and Administrative Code Section 15 A NCAC 2H 1008 Initial in the space provided to indicate that the following design requirements have been met and supporting documentation is attached If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below Attach justification if a requirement has not been met Applicants Initials Form SWU-107 Rev 3 99 a System is located 50 feet from class SA waters and 30 feet from other surface waters b System is located at least 100 feet from water supply wells c Bottom of system is at least 2 feet above the seasonal high water table d Bottom of the system is 3 feet above any bedrock or impervious soil horizon e Off-line system, runoff in excess of the design volume bypasses the system (bypass detail provided) f System is designed to draw down the design storage volume to the proposed bottom elevation under seasonal high water conditions within five days based upon infiltration through the bottom only (a hydrogeologic evaluation may be required) g Soils have a minimum hydraulic conductivity of 0 52 inches per hour h System is not sited on or in fill material or DWQ approval has been obtained Plans ensure that the installed system will meet design specifications (constructed or restored) upon initial operation once the project is complete and the entire drainage area is stabilized System is sized to take into account the runoff at the ultimate built -out potential from all surfaces draining to the system, including any off -site drainage System is located in a recorded drainage easement for the purposes of operation and maintenance and has recorded access easements to the nearest public right-of-way System captures and infiltrates the runoff from the first 1 0-inch of rainfall (1 5 inch event for areas draining to SA waters) Drainage area for the device is less than 5 acres n A pretreatment device (filter strip, grassed swale, sediment trap, etc ) is provided o Trench bottom is covered with a layer of clean sand to an average depth of 4 inches p Sides of the infiltration trench are lined with geotextile fabric q Rock used is free of fines (washed stone) and has a large void ratio Side to bottom area ratio is less than 4 1 Observation well(s) are provided (case -by -case basis) Page 2 of 4 t Vegetated filter is provided for overflow (50 feet for SA waters, 30 feet for other waters) and detail is shown on plans u. A benchmark for checking sediment accumulation is provided IV. UNDERGROUND INFILTRATION TRENCH OPERATION AND MAINTENANCE AGREEMENT 1 After every runoff producing rainfall event and at least monthly inspect the bypass/overflow structure for blockage and deterioration and the infiltration system for erosion, trash accumulation, grass cover, and general condition 2 Repair eroded areas immediately, re -seed as necessary to maintain adequate vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash and blockages as needed to maintain system performance 3 Remove accumulated sediment annually or when depth is reduced to 75% of the original design depth. Restore depth to original design depth without over -excavating Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed 4 The water level in any monitoring wells will be recorded after a l -inch rainfall event and at least once a month Chronic high water table elevations (within 1 foot of the bottom of the system for a period of three months) shall be reported to DWQ immediately 5 if DWQ determines that the system is failing, the system will immediately be repaired or replaced to original design specifications if the system cannot be repaired to perform its design function, other stormwater control devices as allowed by NCAC 2H 1000 must be designed, approved and constructed 5 Remove accumulated sediment from the infiltration system annually or when depth in the umt is reduced to 75% of the original design depth The system shall be restored to the original design depth without over excavating Over -excavating may cause the required water table separation to be reduced and may compromise the ability of the system to perform as designed Removed sediment shall be disposed of in an appropriate manner and shall not be handled in a manner that will adversely impact water quality (Le stockpiling near a storinwater treatment device or shvam, etc ). A benchmark shall be established in the infiltration system. The benchmark will document the onginal design depth so that accurate sediment accumulation readings can be taken. The measuring device used to determine the depth at the benchmark shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments. When the depth at the benchmark reads 2.5" , the accumulated sediment shall be removed from the system. Form SWU-107 Rev 3 99 Page 3 of 4 I acknowledge and agree by my signature below that I am responsible for maintaining the stormwater collection system in accordance with the six maintenance procedures listed above I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party Print Name and Title- _Gerard J SWhaun, Manager__ Address Phone Signatu Note 7 resident of the subdivision has been named the president a Notary Public for the State of N c-r County of do hereby certify that personally appeared before me this .2 '? day of 0 6 and acknowledge the due execution of the forgoing infiltration basin maintenance requirements Witness my hand and official seal, A T Oer Z PUBLIC Z;`+ iIf- O g_2p`^G�`�` My commission expires 6 'j � j t Form SWIJ-107 Rev 3 99 Page 4 of 4 P 1 rTi r mnnr, 620 MEMORY TX COMMUNICATION RESULT REPORT ( OCT 6 2006 10 241PIM )* TTI NCI7ENR WIRO RESU PAGE OPTION — ---------ADDRESS—(GROUP) _-------------- -------- ---- — — 9-19104011620 -------------- REASON FOR ERROR E-3) AN UP OR LINE FAILANSWER E-2) BUSY E-4) NO FACSIMILE CONNECTION State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office (910)796,7215 Michael F Easley, Governor William Gr Ross Jr, Secretary FAX COVER SHEET Date: AP <Ae�e # pages (excluding cover) To: From: Gloria CO: l Division: Express Permittine FAX FAX#: 910-350-2004 REMARKS 127 CaMnel Driva gxtension,'Wllmington, Y,C 2$405,3845 Thlaphone (910) 796-721S Pax(910) JSO-2#04 An tginl Oppornimty Affirmative AMmn Employer i N P 1 FILE MODE 785 MEMORY TX COMMUNICATION RESULT REPORT ( AUG 29 2006 8 55AM ) TTI NCDENR WIRO OPTION ADDRESS (GROUP) RESULT ESU T PAGE - --- ---------------------- -------------------------------� 919104011620 REASON FOR ERROR E-1) HANG UP OR LINE FAIL E-3) NO ANSWER P 3/3 'X74 , 1�"//) C" I . ly, i2 C-� Y) E-2) BUSY E-4) NO FACSIMILE CONNECTION State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Michael F. Easley, Governor Date: 8128106 To: Brad Sedgwlck Company: JBS FAX #: (910) 401-1620 William G. Ross, Jr. Secretary FAX COVER SHEET No. of Pages: 3 (Incl, Cover) From: Paul Bartlett Water Quality Section - Stormwater FAX #: 910-350-2004 Phone #: 910-796-7301 DWQ Storrnwater project Number: SW8 060834 Project Name: 4570 Long Beach Rd. MESSAGE: Brad, A Request for Additional Information is attached for the subject project. The original will be mailed to Mr. Skehan, and a copy'will be mailed to you. State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Michael F Easley, Governor Date: 8/28/06 To. Brad Sedgwick Company- JBS FAX #: (910) 401-1620 William G Ross, Jr, Secretary FAX COVER SHEET No. of Pages: 3 (Incl Cover) From: Paul Bartlett Water Quality Section - Stormwater FAX #: 910-350-2004 Phone #: 910-796-7301 DWQ Stormwater Project Number: SW8 060834 Project Name: 4570 Long Beach Rd MESSAGE: Brad, A Request for Additional Information is attached for the subject protect The original will be mailed to Mr Skehan, and a copy`will be mailed to you /0 ENBlptb S1WQSISTORMWATERIADDINF0120061060834 aug06 127 Cardinal Drive Extension, Wilmington, NC 28405-3845 Telephone (910) 796-7215 FAX (910) 350-2004 An Equal Opportunity Affirmahve Action Employer W A J � 0 Y August 28, 2006 Mr Gerard J Skehan, Member -Manager Darske, LLC 42 Yaupon Way Oak Island, NC 28465 Subject- Request for Additional Information Stormwater Project No SW8 060834 4570 Long Beach Road Brunswick County Dear Mr Skehan Michael r Easley, Go%emor William G Ross Jr , Secretary North Carolina Department of Environment and Natural Resources Alan W Klimek P E Director Division of Water Quality The Wilmington Regional Office received a Stormwater Management Permit Application for 4570 Long Beach Road on August 22, 2006 A preliminary review of that information has determined tha he application is not complete The following information Is needed to continue the ormwater review Please provide (a) a site plan with contour elevations that are In FMSL, and (b) elevations in FMSL entered on all supplements It appears that elevations are benchmarked to 100' on all documents Please cl nage Area C The Drainage Basin Map In the calculations lasts *Please �ft (0 3 ac) and 0 47 ac was used in the calculations ff� 13clarify the total pipe I far Trenches A and B The cal ons list Lye Sheet #C2 labels 43 ength, and the supplement list c ' 4clarify the " rid "B" trench length based on a single run of pipe The supplement list but Sheet #C2 illustrates an ppro mate length of 350' q_3 zr P clarify the storage volumb for systems "A" and "B" The supplement lists 59 8Cu ft, and the calculations list 559 cu ft 6 Based on Items #1 through #5 above, please modify all plans and documents for 0 consistency Please note that this request for additional Information Is in response to a preliminary review The requested information should be received by this Office prior to September 6, 2006, or the application will be returned as incomplete The return of a project will necessitate resubmittal of all required items, including the application fee If you need additional time to submit the information, please mail or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter The request must Indicate the date by which you expect to submit the required Information Npr hCarolma Naturn!!Y North Carolina Division of Water Qualit) 127 Cardinal Drive Extension Wilmington, NC 28405 Phone (910) 796 7215 Customer Service Wilmington Regional Office Internet www newateiqualaN org rax (910) 350 2004 1 877 623 6748 An Equal OpportunitylAffirmative Action Employer— 50% Recycled110% Post Consumer Paper Mr Gerard J Skehan, Member -Manager August 28, 2006 Stormwater Application No SW8 060834 The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215 1 and is subject to enforcement action pursuant to NCGS 143-215 6A Please reference the State assigned protect number on all correspondence Any original documents that need to be revised have been sent to the engineer or agent All original documents must be returned or new originals must be provided Copies are not acceptable If you have any questions concerning this matter please feel free to call me at (910) 796-7301 Sincerely, k- Paul T Bartlett, P E Environmental Engineer ENBlptb SIWQSISTORMWATERIADDINFO120061060834 aug06 cc Brad Sedgwick, P E Paul Bartlett Page I of I North Carolina ,Elaine F. Marshall D E PARTM E SIT o» THE Secretary SECRETARY of STATE Corporations •Corporations Home •Important Notice •Corporations FAQ •Tobacco Manufacturers •Dissolution Reports •Non -Profit Reports *Verify Certification •Online Annual Reports •KBBE B213 Annual Reports Links •Secretary Of State Home •Register for E-Procurement *Dept of Revenue Legislation •1999 Senate Bills •2001 Bill Summaries •Annual Reports 1997 *Corporations 1997 Search *By Corporate Name *For New Corporation •By Registered Agent Online Orders :Start An Order •New Payment Procedures Contact Us *Corporations Division •Secretary of State's web site Print •Printable Page PO Box 29622 Raleigh, NC 27626-0622 (919)807-2000 Date 8/28/2006 Click here to View Document Filings I IN Print apre-populated Annual Report Form I Annual Report Count I Fil an Annual Report I Corporation Names Name Name Type NC Darske, LLC Legal Limited Liability Company Information SOSID 0745750 Status Current -Active Date Formed 9/29/2004 Citizenship Domestic State of Inc NC Duration 12/31/2099 Registered Agent Agent Name Registered Office Address Registered Mailing Address Principal Office Address Principal Mailing Address Skehan, Gerard 42 Yaupon Way Oak Island NC 28465 42 Yaupon Way Oak Island NC 28465 42 Yaupon Way Oak Island NC 28465 42 Yaupon Way Oak Island NC 28465 For questions or comments about the North Carolina Secretary of State's web site, please send a -marl to Webmaster http //www secretary state nc us/Corporations/Corp aspx?PitemId=6532986 8/28/2006 State of North Carolina Department of the Secretary of State Limited Liability Company ARTICLES OF ORGANIZATION SOSID• 0745750 Date Filed- 9/29/2004 2.06:00 PM Elaine F Marshall North Carolina Secretary of State C200427100152 Pursuant to §57C-2-20 of the General Statutes of North Carolina, the undersigned does hereby submit these Articles of Organization for the purpose of forming a limited liability company The name of the limited liability company is T Darske, LLC If the limited liability company is to dissolve by a specific date, the latest date on which the limited liability company is to dissolve (If no date far dissolution is specified, there shall be no limit on the duration of the limited liability company) Recember 31, 2099 The name and address of each person executing these articles of organization is as follows. (State whether each person is executing these articles of organization in the capacity of a member, organizer or both Note This document must be signed by all persons listed here) Robert_K. Serra is executingthese Articles of Organization in the capacity of organizer. His address is 104 Price St., Oak Island, NC 28465 4 The street address and county of the initial registered office of the limited liability company is Number and Street _. 42 Yaupon way City, State, Zip Code Oak Island, _ NC , 28465 -County Brunswick 5 The mailing address, if different from the street address, of the initial registered office is 6 The name of the initial registered agent is Gerard Skehan 7 Principal office information (Select either a or b) a © The limited liability company has a principal office The street address and county of the principal office of the limited liabtlity company is Number and Street _ _ 42 Yaupon Way City, State, Zip Code Oak Island, NC 28465 _ _County Brunswick The mailing address, if different front the street address, of the principal office of the corporation is b ❑ The limited liability company does not have a principal office 9 Check one of the following, X (i) Member -managed LLC all members by virtue of their status as members shall be managers of this limited liability company The initial members will be Gerard Skehan and Milton C. Darr (ii) Manager -managed LLC except as provided by N C G S Section 57C-3-20(a), the members of this limited liability company shall not be managers by virtue of their status as members 9 Any other provisions which the limited liability company elects to include are attached 10 These articles will be effective upon filing, unless a date and/or time is specified This is the 24 day of _ _September , 20_o4 !� Signature Robert: K. Serra, Organizer Type or Print Name and Title NOTES 1 Filing fee is $125 This document must be filed with the Secretary of State. CORPORATIONS DIVISION P O Sox 29622 RALEIGH, NC 27626-0622 (Revised January 2002) (Form L-01) Instructions for Filing C200613901186 LIMITED LIABILITY COMPANY e ANNUAL REPORT NAME OF LIMITED LIABILITY COMPANY Darske, LLC FISCAL YEAR ENDING SECRETARY OF STATE R L L P ID NUMBER 0745750 NATURE OF BUSINESS Contractor REGISTERED AGENT Skehan, Gerard REGISTERED OFFICE MAILING ADDRESS 42 Yaupon Way Oak Island, NC 28465 SOSID: 0745750 Date Filed: 5/18/2006 8.59.00 AM Elaine F. Marshall North Carolina Secretary of State C200613801186 STATE OF INCORPORATION NC FEDERAL EMPLOYER ID NUMBER 20-1876436 REGISTERED OFFICE STREET ADDRESS 42 Yaupon Way Oak Island, NC 28465 Brunswick County SIGNATURE OF THE NEW REGISTERED AGENT SIGNATURE CONSTITUTES CONSENT TO THE APPOINTMENT PRINCIPAL OFFICE TELEPHONE NUMBER (910) 278-9084 PRINCIPAL OFFICE MAILING ADDRESS 42 Yaupon Way Oak Island, NC 28465 PRINCIPAL OFFICE STREET ADDRESS 42 Yaupon Way Oak Island, NC 28465 MANAGERS/MIrMBERS/ORGANIZERS Name Gerard 5kehan Name Milton Darr Title manager Title Manager Address Address 42 Yaupon Way P O Box 884 Oak Island NC 28465 Oak Island NC 28465 CERTIFI ON OF AL REPORT MUST BE COMPLETED BY ALL LIMITED LIABILITY COMPANIES FORM MUST BE SIGNE Y ANAGER/MFMBER TYPE OR PRINT NAME L4_��.o� DATE TYPE OR PRINT TITLE ANNUAL REPORT FEE $200 MAIL TO Searetary of State* Corporations Divucon • Post ORiee Box 29525 • Raleigh, NC 27626.0525 If i ■iiat 0 : , r l� 1 1� 11 IA ■,: rIN- 1111tImmin Inii rl iir . t TspoZone - USGS Southport (NC) Topo Map Page 1 of 1 0 OA 02 0.3 0.4 05km I 0 0 09 0.18 0 27 0 36 0 45 mi 330 56' 29"N, 780 03' 30"W (NAD83/WGS84) USGS Southport (NC) Quadrangle M=-B 816 Projection is UTM Zone 17 NAD83 Datum G=1.644 http //www topozone com/pnnt asp?lat=33 94139&lon=-78 05833&s=24&size=m&u=6&1 8/28/2006 MapQuest Maps Page I of I Oak Island NC Us Notes: 570 Long Beach Road MAP%V;ST,,; •THeAMOCO M ULTIM'ATE% T To , 5i1 1 3 t t _ , ENTER NOW 02006 NAVTEQ All nght6_r�served Use Subject to License/Co2Ynpht This map is informational only No representation is made or warranty given as to its content User assumes all risk of use MapQuest and its suppliers assume no responsibility for any loss or delay resulting from such use http //www mapquest com/maps/print adp'?mapdata=GMCh6ITzs94iYpbsvEB4gDMyrxG 8/28/2006 NCDENR - Express Permitting 127 Cardinal Drive Extension Wilmington, NC 28405 ATTENTION Cameron Weaver WE ARE SENDING x Originals II Specifications LETTER OF TRANSMITTAL DA1E August 8, 2006 PROJECT NO 038-001 TASK NO RE 4570 Long Beach Road TRANSMn-TAL NO 1 PAGE 1 OF 1 Prints Calculations ❑ Shop Drawings ❑ Samples 2 Other - Applications Quantity Drawing No Rev Description Status 2 C1 & C2 Construction Plans G 2 Stormwater Calculations and Supporting Data Report G 2 Stormwater Management Permit Application form G 2 Infiltration Trench Supplement form for Basin #A G 2 Infiltration Trench Supplement form for Basin #B G 2 Infiltration Trench Supplement form for Basin fe G 1 $2000 00 application fee check / G 8 A Issue Status Code A Preliminary B D Fabrication Only C For In rmawl� l3 k Jw E Construction F For Review & Comments G Fo rovW See Rema Action Status Code 1 No Exceptions Taken 2 Make Corneebons Noted 3 Other 4 Amend & Resubmit 5 Rejected - See Remarks REMARKS 8 66 03V � zoos 7332 CoWswoM Dma Vftw m NC-M0-619-9990��4fajt 1 B1D 79Q-976D Cc File Copy JB onsull�jpg, PA ti� CONSULTING, PA 7332 Cotesworth Dnve JBS Wilmington, NC 28045 (910) 619-9990 Fax (910) 401-1620 PLANNING - ENGINF.PRn4c; - CONsTRucnoN mANAGEMENT NCDENR 127 Cardinal Drive Ext Wilmington, NC ATTENTION Cameron Weaver WE ARE SENDING x Originals ❑ Prints ❑ Specifications ❑ Calculation LETTER OF TRANSMITTAL DATE 8-�22-06 PROJECT NO TASK NO RE 4570 Long Beach Road TRANSMITTAL NO PAGE 1 OF 1 ❑ Shop Drawings ❑ Samples s ❑ Other - Quantity Drawing No Rev I Description Status 1 1 Check for $2,000 (Additional Fee for High Density) Issue Status Code A Preliminary B Fabrication Only C For Information D Bid E Construction F For Review & Comments G For Approval H See Remarks Action Status Code 1 No Exceptions Taken 2 Make Corrections Noted 3 Other 4 Amend & Resubmit 5 Rejected - See Remarks REMARKS cc File Copy 7332 CoteawWfh Onve VAtmmpton NC Phone Signed 1990 Fax 1 910-401 1620 Consulting, PA AMA 012 &-/ NVR North Caroima DepaMnent of Ermonment and Natural Resources 127 Cardlna]Dn7 e, Wilmirow NC 211405 (910) 79&7307 FAX (910) 350-2004 Request for Express Permit Review FILL-W affi»formation below and CHECK required Permit(s) r`S��' �� �` FAX or email to Cameron. Weaver ncmad net along with a narrative and vicinity map of the project, location. Prajects must be submitted by 9:00 A.M.of the review date, unless prior arrangements are made. PPLA ICANT I Company PROJECT Name q 5'}0 PROJECT SYSTEM(S) TRIBUTARY TO 0,!jF' C$ L- L� (STREAM NAME) Company Cox t i"' ,�417^t ! T, e-j f j<W f P —LN W Address Z i e51AX177 ate ) L ) Wq i�� A J' County.A) Phone 910 • A1'r -S4gC5 F •`i10 - 101.16Z�,5Email e. tf=7'1Y)41L>cQ State or National Environmental Policy A ;t (SEPA, NEPA) - EA or EIS Required ❑ Yes ]R No N STREAM ORIGIN Determination; # of stream calls, Stream Names ❑ STORMWATER ❑ Low Density ❑ High Density -Detention Pond ❑ Hugh Density -Other Wetlands MUST be addressed below ❑ I_ow,Density-Curb & Gutter Hugh Density -Infiltration ❑ Off Site k COASTAL ❑ Eccavatlan & Fill ❑ Bndcg'es & Culverts [ Structures Information MANAGEMENT ❑ Upland Development ❑ Manna Develeprnent ❑ Urban Waterfront LAND QUAW Y ❑ Ewori and Sedimentation Control Plan vnth acres to be disturbed T WETLANL)S (401) Wetlands on Property ❑ Y Nv Isolated Wetlands on Property' [I yes 9 No Check all that a' I Wetlands will se Impact t j Yes No Wetrarrd impacts AcreW Wetlands bdineabon has been completed ❑ Yes ❑ No' ❑ Butlers Impacted re(s) hid USA COE Approval of Delrrreabon completed ❑ Yeas ❑ No 404 Applucabon in process w1USACOE ❑Yes ❑No I Permit received from U$ACE ❑Yes []No 401 Application required ❑Yes ❑ No if Yes, ❑ Regular ❑ Express Additional fees, not to exceed 90% of the original Express Review permit application fee, may be charged for subsequent reviews due,to the insufficiency of the permitapplications. Fot DENR use only ;SUBMITTAL DATES: Fee Split for multiple permits. SW $ CAMA $ LQS 401 $ Total Fee Amount $ INFILTRATION SITE VISIT REQUEST Name of the Project : Y,5-7<n �.00 q 3&6c # � Location (attach a clear vicinity map), 1 t"1c-)qEP , Sbvet address. SR number cwmunity, etG Directions from the nearest mayor intersection ` r1 Z L�O '--A—) c -D c ,Ti -—^�c)yrft?°F is t: 5 ce.— �.t u1+v> 17 4 Owner/Applicant Name Consultant Name LOI CK Consultant Contact Information:�ia'- 611- ` ftor*. fax, email, ete, SE 1P, ff i`Ae- riE3> 7I.Prj Existing ground elev @basinftrench= SHVVT elev = SHVVT plus 2' (max bottom elev )= Dateff-ime of Sods Investigation Summary/Comments. .00 Wo QJ Le i M �►r �. con #1 #2 #3 #4 #5 #6 #7 #8 All proposed irtfiltration areas and emiting, adxve utility lines,located within the proposed basin/trench must be marked and flagged. If these areas are'not flagged, the Soils, Scientist reserves the right to decline to do the investigation if the �r�oposed infiltration system will be located in an area of�existing ' pavement and there is no open area nearby, equipment,capable of breaking through the impervious layer must be provideid The soils invesgabon does nof take the place of a soils report prepared by an appropnate professional The Soils Scientistvnll'only verity the soil conditions that are reported in the Soils Report,,and make a determination as to the suitability of the site'to meet the Infiltration design *uirements under NCAC 2H I000,rand assumes no liability should the system fail ,,Checklist for Express Permithng, For,Qffsite projects Has the Ciestgner's Certification for the off de system °been submitted? Have the deed restrictions been recorded and,submitted? For Infiltration Projects Has Vincent been to the sde_for the soils For All rojeCts Cs,the'proiect Low denstty,5curb outlet, wet pond, ratio , or offsiie If there are'wetiand issues,, has the 4011404 permit been, issued, or is it also going Express''? NO u15'7 , >?s C,rJ C If the applicant is a corporate entity, :s the entity registered with the Secretary of State) C'211y M � <-- ti e P Look up the'of ite system on BIMS,to see if these events have occurred You may also wan# to -pull the file to see ifthe documents were received but not logged onto BIMS Call Vincent and ask him Linda may have,a paper record, of the sate visit in her office NCDER STORMWATER CALCULATIONS AND SUPPORTING DATA 4570 LONG BEACH ROAD Oak Island, NC Brunswick County June 23, 2006 Prepared for Darske, LLC 42 Yaupon Way Oak Island, NC 28465 Prepared by JBS Consulting 7332 Cotesworth Dr Wilmington, NC 28405 4570 LONG BEACH ROAD Oak Island, NC Brunswick County June 23, 2006 Table of Contents DESIGN NARRATIVE Existing Site Proposed Improvements Post Developed Basin Maps 1" Treatment Volume Calculations Stream Classification Geotechnical Report by ECS 4570 LONG BEACH ROAD Oak island, NC Brunswick County June 23, 2006 DESIGN NARRATIVE Existing Site Darske, LLC is proposing the development of a 1 03 acre tract of land, in Brunswick County The proposed project site is located at 4570 Long Beach Road (NC 133), just to the north of North Hampton Drive The site is currently undeveloped Figure 1 - USGS The Brunswick County SCS Soil Survey indicates that the property's sal is Yaupon silty clay loam (YaB) Yaupon silty clay loam is a poorly drained to moderately well drained clayey soil Surface runoff is slow and permeability is slow Engineering Consulting Services, LTD preformed a field geotechnical investigation of the sites There report indicates that the soils on the site have an infiltration rate of 3 3 to 4 2 inches per hour at the tested depth of 8" inches below grade and a seasonal high water table at a depth of 24 to 30 inches below grade A copy of their report is included in this report No wetlands have been identified on the property The property is located in a basin that drains to the Calf Gully Creek, within the Lumber River Basin and is not classified Proposed Improvements The proposed development will consist of 4 retail/office units, paved access drives and parking, the necessary utilities services will be provided from the existing infrastructure and a stormwater management system will provide treatment and pre/post attenuation The site will be accessed from Long Beach Road A total of 40 parking spaces are provided to serve the development The proposed impervious areas will are made up of 10,000 sq ft of buildings, 22,754 sq ft of asphalt and 1,850 sq ft of concrete paved areas, making the total built upon area 33,306 sq ft , 77 1 % of the 1 03 acre total property area NCDENR requires that a BMP be provided to remove stormwater pollutants (treatment) from the first 1" runoff In order to meet the treatment and attenuation requirement, the project's stormwater runoff will be captured in infiltration trenches The trench bottom will be a minimum of 2' above the seasonal high water table A bypass overflow structure is provided to discharge excess stormwater The infiltration trenches will draw down in 2 to 5 days a , r ECSICRMHA214 LLP Geofthnical . Constiuctidn Mate Ea►vuanmeotd , , u t , s Jima 6; 2006 Mr. Brad SSetlgvAck, PM „{ ' Ji3S C 6�g, A. k 7332 Co north Drava pp �r �y/� Y��p ryp�//{{ , &� Wor&Cwol��28B 056 + t t, 'i, , ze 9 k „k 4, a RV 1DMtLation Eviluiboli r q; Road 4570 � Bsaah (�p� �4��Ii�{ln� ��{� �y.y���yp Z 5 v/ak J�iW,aV.A3 YI6�AiWiilW k y } ECS4, Ltd. Project No 2212208 ,'t 1� My t Der bar. Sedgmc ; 4 S, ECS CaTO�lAB, ,L '�'} Iec=' Uy conducted an (iIla eVa1 oI1 fi)r,tbo prroposed loca#ron (Itl the 'posed, site at 4570 Larng Beach Road M" Oak :61 1 NoI' ) Carolma. This letter,iwith aLtaCl]IIiCLw the 1ep01k all [lla, � 1 a 5 FI� l"nvmdgitla2fi , 15 °, , Ik, On Jima 1,32006. ECSS condimC ed an eipl6Atioa6 of 'the subsurface soil and ground'Awater1, > conditions at two died locataons`shown on the atbaahed6Sit* Diagram. The purpose+ of f3 is ea10ratiou was to obtain sub"oe mforfiiaton of the id abili'iy of the Iin-place sods far tfie, „ a, proposed li ilirgiian area. Vel6erapiarad the -I-surfecv wil zr d,'gt+ound water conditions by " ` , ad�iautdng two band, anger,,170rIDgs into , the CUgbng ,gravid' surface at the requested test" j loc�dons We vrsuialiy cliasified tlae mib$�e Isolls,md obtansd^ reparesentat ►e asinples of ' ea soul type enco d.1}We also =wdud the ground water Ie d observed at the tie of the land auger, boiinf. Thek staac�xcd Infiitra�ian R�relusl on,Foam�psovl ; a summary"of<tiie subsurface oendlitaans'encountered at each head auger ba mg location. Ground water was note ounterei during ' of r ezp1mution at the rquested test locahons up to a depth of 72 in" below ttie'euustnog grade r evatian. The}se mo high ground water level , Y (MWL) at location 01 was os� to be at a'dkA of 30 inch. The seasonal high water lvvdl,(SRWL)`at f66ati,aaa #2 was estimated to be at a dep6of24 inks. ,a 6 3 We have conducted}rnfiltratian teats ncar our hand auger �bs to est►mste the mfilba ittva rate, for the subsurface smile. The infiltration tests Vera conducted approxumdely 8 inches below the 1 ` emszg gtade,elevatiun. il 1 7211 Ogden'Busmess IFa* -Suite 201 - %rt &Won; NC 2841,1 - (910) 68&,9114 • Faa (910) 686-9666 ' , n � , , r ak , t 4 1 � t ' ' Ook Wunck Nm* Cmulins A „ EC8 ProjesetNc.22.12208` 'MildA Text e�t's� fEi EY i E f At location #l; the infltiatxoa test was padbm2od at S inohes'iu'rbrown dhy ; SAND n medicated ammfiiitcanoh ralo of 01074indm per minute (4.2"indbes per h: v) AtElocatiou #2; the � „ „ r tom.. �?►� tW waa pmf rz ed st 8 des in browu aflty'ffino SAND and xudiaated as infilirahon iiteof0.06'mcb sperEmi ts'(33ru>�edpeT�hour}. ,lnfiltrat� rates, may'vmy wxffi�n the' Proposed` site ;dueA6 posmible, changes in subsurface t 7rA ;+y�ayy�� I4 1mve WS } 1 1 you Y queatsong re��`thls Ix�ort, piB$8c cvutaai r� at (910) b86-911'�4. i f sS � fr1 ➢ 1 8 p 1 � iE i F 1 y' ECS "A OLDUS, LLP ` f1 s � r v + t i Winslow R Goms, E.I " Wand M. Sob% P E. ail` f v� f IJ caps En& It f 1 1 NC Laomset No. 22983 c 4 ` '&W it rl Yx 1T t s s E> s ' s Boring LocWcm ..fr Li.l afi(m `S Y } 44e s Ei° r F i S i3 N E t� r 1 9 q f E 1 4 r is ri � a 44 4 � _ ` k - - y w..,...rw.� � - �.� ...• ,. � ., T r �...r!' P � ....,.,�,o. r' _ �` M - N T , r J. A? 4r A - co jet _ DENOTES APPRO)aMATE LOCAT03 N OF INFILTRATION TEST - - a INMMTTON TESTY - - REirrcE: _ WC -ION- SITE" MAP- PROVIDED HY JHS 4570 LONG BEACH ROAD NOT TO SCALE _ _ CONSMTINO.- PA_ - UP 0" MLAND- NORTH CAROLINA 1 i 63 4 9 I y I tration'Evaluation 1 I { 1 i 4570` L`og Beach Road i n t , 5 Oak Islarid,, North. CaroUw t ECS Troj ect No. 22,12208 .June,6; 2006, F ' ,,Location i ,� it Des' Pgon #1 ` 0=,72" Brpwn silty fine SAND 1 I Seasonal Higb Water Table was estimated to be 30 inches belowathe existing' grade 1 , elevation. Tnfiltzation Rate: d ,A:07 inches,per minute, (4.21inches per hour) Test was conducted, at S inches below existing grade,elevation „ i 1 4 f It i, 11 I Y rF i Ground water was not encountered up to 72 inches the existing grade r 3 4r j elevation. , Luca ' n Depth Soil lit ion ' #2 ,� " '0-725t li .Brown, silty fine{SAND ,, � 1 Seasonallbigh Water Table was`estimatedtto be 24 ;mches below the exiistirig g del i t ek � lion. 11 }S k rs I 1 1 1 1 1 I 3 li t t 1) I if i x 1 Infilfiit o.j'n Rate: ' 0.06, i 6es per minute (3.3 inches per hour) Test was conducted at S inches below CM" sting grade elevation Ground water was not encountered up, to, 72 inches below the eodsting grade F tE elevation. on., 1 a n i13 5 S i 1 S , i s it if e ay' yl S t + i j E < y t jss a i 1 4t it P i 1 { \ i i 1 f i • r• \Y L �- [i •j �i •.i.j� � +rulr—riv. ��� mil;It — � LOANO� BEACH HT 17FC WAY�r� ------- -i---rrrrr -rT�r - err----- -� - NO. nRAINAfZ ANC EROSION CCMTRCI {��.j fLK M ur.It IYItl Ras�ul�w Iwwi � � of NILET Sftl11dTA L STOP wllr. -o wu.r ww axaw �- .t»>m NO NETLANOS COST DN 9TL Q MMM-CmTROL Nams �Siscsas :- !IL Yl���rri �111 memixmnN aasurr �nr .Irin..wr r.r.ar rr n. r rr. rr rrw F Il�al•\ • A i1111 owSft". C 11s IM-.4ai In NrY1�.1 NCDENR North Carolina Department of Environment and Natural Resources Division of Land Resources James D Simons, PG, PE Land Quality Section Michael F Easley, Govemor Director and State Geologist William G Ross Jr, Secretary July 24, 2006 LETTER OF RECEIPT OF EROSION CONTROL PLAN Darske, LLC Gerard J Skehan, Manager 42 Yaupon Way Oak Island, NC 28465 RE Protect Name 4570 Long Beach Road Protect ID Bruns-2007-032 County Brunswick, Oak Island, Long Beach Road River Basin Lumber Submitted By JBS. Consulting, PA Date Received by LQS July 24, 2006 Plan Type NEW Dear Mr Skehan REC FIvEU JUL 2 5 ?006 BY This office has received a soil erosion and sediment control plan for the protect listed above which was submitted as required by the North Carolina Sedimentation Pollution Control Act (G S 113A-57 (4)) The Act requires that all persons disturbing an area of one or more acres of land must obtain approval of a soil erosion control plan prior to the commencement of the land -disturbing activity (G S 113A-54(d) (4)) The Act further states that this plan must be filed a minimum of 30 days prior to the activity and the approving authority must approve or disapprove the submitted plan within 30 days of receipt Failure of the approving authority to approve or disapprove the submitted plan within the 30-day period will be deemed approval of the plan Commencement or continuation of a land -disturbing activity under the jurisdiction of this Act prior to the approval of an erosion and sediment control plan is a violation of the Act We have performed a preliminary review of your submitted plan and have determined that additional information will be necessary before a Final review can be completed Enclosed is a checklist of items that must be submitted before we can complete the review process Failure to provide the additional information may result in disapproval of your plan The approval of an erosion and sediment control plan is conditioned on the applicant's compliance with Federal and State water quality laws, regulations and rules If you have questions please do not hesitate to contact this office Your cooperation in this matter is appreciated and we look forward to working with you on this project Sincerely, Schu ler J Snowdon Y Env Tech V Land Quality Section cc Bradford Sedgwick, JBS Consulting, PA LQS-WiRO, SWS-WiRO Wilmington Regional Office 127 Cardinal Drive Ext , Wilmington, North Carolina 28405-3845 - Phone 910-796-72151 FAX 910-350 2004 NORTH CAROLINA DEPARTMENT OF ENVIRONMENT &, NATURAL RESOURCES LAND QUALITY SECTION EROSION and SEDIMENTATION CONTROL PLAN PRELIMINARY REVIEW CHECKLIST PROJECT NAME 4570 Lona Beach Road DATE 7124/2006 PROJECT NO Bruns-2007-032 COUNTY Brunswick To expedite the approval process, a cursory review of your submitted Erosion and Sediment Control Plan application has been made and has shown the need for additional information as specified below To meet our review schedule, any additional information should be received by this office no later than _ Auciust 13, 2006 Failure to meet this schedule may result In disapproval of your plan The following items shall be incorporated with respect to specific site conditions, in an erosion and sediment control plan LOCATION INFORMATION Project location (roads streets landmarks) North arrow and scale GENERAL SITE FEATURES (Plan elements) Legend North arrow scale etc Property lines Existing contours (topographic lines) Proposed contours _X_ Limits of disturbed area (provide acreage total delineate limits and label) Planned and existing building locations and elevations Planned & existing road locations & elevations Lot and/or budding numbers Geologic features rock outcrops seeps springs wetland and their limits, streams lakes ponds dams, etc Easements and drainageways Profiles of streets, utilities ddtchlines etc Stockpiled topsoil or subsoil locations If the same person conducts the land -disturbing activity & any related borrow or waste activity the related borrow or waste activity shall constitute part of the land-d sturbing activity unless the borrow or waste activity is regulated under the Mining Act of 1971 or is a landfill regulated by the Division of Waste Management If the land-dstufbing activity and any related borrow orwaste activity are not conducted by the same person they shall be considered separate land -disturbing activities and must be permitted either thru the Sedimentation Pollution Control Ad as a one -use borrow site or through the Mining Act Required Army Corps 404 permit and Water Quality 401 certification (e g stream disturbances over 150 linear feet) EROSION CONTROL MEASURES (on plan) Legend Location of temporary measures Location of permanent measures X Construction drawings and details for temporary and permanent measures Maintenance requirements of measures Contact person responsible for maintenance SITE DRAINAGE FEATURES Existing and planned drainage patterns (include off site areas that drain through project) Method of determination of and calculations for Acreage of land being disturbed Size and location of culverts and sewers Soil information type special characteristics Sod information below culvert storm outlets Name and classification of receiving water course (only where storm water discharges are to occur) Comments STORMWATER CALCULATIONS X Pre -construction runoff calculations for each outlet from the site (at peak discharge points) ,_,_X_ Design calculations for peak discharges of runoff (including the construction phase & the final runoff coefficients of the site) _X_ Design talcs of culverts and storm sewers _X_ Discharge and velouty calculations for open channel and ditch flows (easement & right -of ways) _X_ Design talcs of cross sections and method of stabihzdtion of existing and planned channels (include temporary finings) _X_ Design talcs and construction details of energy dissipators below culvert and storm sewer outlets (diameters & apron dimensions) Design talcs and dimension of sediment basins Surface area and settling efficiency information for proposed sediment traps and/or basins VEGETATIVE STABILIZATION Area & acreage to be vegetatively stabilized Method of soil preparation Seed type & rates (temporary & permanent) Fertilizer type and rates Mulch type and rates NOTE Plan should include provisions for groundcover on exposed slopes within 15 calendar days, following completion of any phase of grading, permanent groundcover for all disturbed areas within 15 working days or 90 calendar days (whichever is shorter) following completion of construction or development FINANCIAL RESPONSIBILITYIOWNERSHIP FORM Completed signed & notarized FRIO Form Accurate application fee ($50 00 per acre rounded up the next acre with no ceding amount) Certificate of assumed name if the owner is a partnership Name of Registered Agent (d applicabie) _X_ Copy of the most current Deed for the site NOTE For the Express Permitting Option, inquire at the local Regional Office for availability NARRATIVE AND CONSTRUCTION SEQUENCE Narrative describing the nature and purpose of the construction activity _X_ Construction sequence related to erosion and sediment control (including installation of critical measures prior to the initiation of the land -disturbing activity & removal of measures after areas they serve are permanently stabilized) Bid specifications related only to erosion control 1 The financial responsible person(s) or firm(s) on the Financial Responsibility/Ownership Form must match the deed 2 There are multiple culverts shown on the plans, without limits of disturbed area it Is not possible to determine existing from proposed 3 Please provide detail drawings outlet protection