HomeMy WebLinkAboutSW8060742_HISTORICAL FILE_20061024STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE YYYYMMDD State Stormwater Management Systems Permit No. SW8 060742 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Brian K. Keesee & Brian Keith Keesee Construction, Inc. Oak Island Building Supply 4255 Long Beach Road, Southport, Brunswick County FOR THE construction, operation and maintenance of two underground infiltration trench systems in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until October 24, 2016, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described in Section 1.7 on page 3 of this permit. The stormwater controls fc r Drainage Areas 01 and 02 have been designed to handle the runoff from 76,000 ft and 14,051 ft of impervious area, respectively. 3. The design storm for each system is 3 inches therefore a vegetated filter is not required. Runoff in excess of the design storm is intended to bypass through the top of the catch basins and flood the parking areas until it can infiltrate. 4. The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans. 5. All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements. The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans. 6. The runoff from all built -upon area within the permitted drainage area of this project must be directed into the permitted stormwater control system. Page 2 of 7 State Stormwater Management Systems Permit No. SW8 060742 rI The following design criteria have been provided in the infiltration trench and must be maintained at design condition: a b. C. d. e. f. h. i. 1. k. i. m n. o. Drainage Area, acres: Onsite, ft Offsite, ft2: Total Impervious Surfaces, ft2: Design Storm, inches: Trench Dimensions, L x W x H, ft: Perforated Pipe Diameter/Length: Bottom Elevation, FMSL: Bypass Weir Elevation, FMS.. : Permitted Storage Volume, ft Type of Soil: Expected Infiltration Rate, inlhr: Seasonal High Water Table, FMSL Time to Draw Down, hours: Receiving Stream/River Basin: Stream Index Number: Classification of Water Body: II. SCHEDULE OF COMPLIANCE DA 01 DA 02 1.74 0.55 76,000 24,000 0 0 76,000 14,051 3 3 334.5x25.25x4 156.5x11 x4 nla nla 16.5 16.5 21.5 21.5 19,176 3,590 Med, to Fine Sand (both) 14.8 14.8 14.5 14.5 12 5 Calf Gully Creek / Cape Fear CPF17 18-88-9-3-3-1 "SC Sw HQW" The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended. use prior to the construction of any built -upon surface. 2. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 3. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in .its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of slopes and the vegetated filter. d. Immediate repair of eroded areas. e. Maintenance of all slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of bypass structure, filter media, flow spreader, catch basins, piping and vegetated filter. g. A clear access path to the bypass structures must be available at all times. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. 5. The facilities shall be constructed as shown on the approved plans. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 6. If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. Page 3 of 7 State Stormwater Management Systems Permit No. SW8 060742 7. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. A modification may be required for those deviations. 8. Access to the stormwater facilities shall be maintained via appropriate easements at all times. 9. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below.. a. Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area or to the drainage area. e. Further subdivision, acquisition, lease or sale of all or part of the project area. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. 10. The permittee shall submit final site layout and grading plans for any permitted future areas shown on the approved plans, prior to construction. 11. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction. 12. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. III. GENERAL CONDITIONS This permit is not transferable except after notice to and approval by the Director. In the event of a change of ownership, or a name change, the permittee must submit a formal permit transfer request to the Division of Water Quality, accompanied by a completed name/ownership change form, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request. 2. Failure to abide by the conditions and limitations contained in this permit may subject .the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal) having jurisdiction. Page 4 of 7 State Stormwater Management Systems Permit No. SW8 060742 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility. 6. The permit may be modified, revoked and reissued or terminated for cause. The filing -of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. 7. Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. 8. Approved plans and specifications for this project are, incorporated by reference and are enforceable parts of the permit. 9. The permittee shall notify the Division any name, ownership or mailing address changes within 30 days. Permit issued this- a 24th day of October 2006. NO CAROLINA V NMENTAL MANAGEMENT COMMISSION .ror Alan W.Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission Page 5 of 7 It r 1W 1E71-LJGC;-11*N4S- I-1-glXle-cril-Ig <'&-- surveying; Inc. P.O. Box 11351, Southport, NC 28461 PH: 910-278-1226 Fax: 866-597-4820 September 19, 2006 Linda Lewis NC DENR Division of Water Quality 127 Cardinal Drive Ext. Wilmington, NC 28405 RE: Oak Island Building Supply Stormwater Project No. SW8 060742 Dear Ms Lewis, We are responding to your comment letter dated September 7, 2006 as follows: Issues are addressed as they were on your comment letter which is attached. 1) Pages 1 & 4 of the Stormwater Management Permit Application Form have updated corporate information. 2) An additional detail on page 01.1 without the Stormtech system obstruction is provided. 3) The roof drain "rock boxes" have been eliminated on pages 01.0 and 01.1. 4) Page 4 of the Stormwater Management Permit Application Form has been updated. 5) Text referring to stone above Stormtech system has been changed so as to not infer that it is counted as storage volume. 6) Page 4 of the Infiltration Trench Supplement and page 4 of the Stormwater Management Permit Application Form have been provided with original signatures. 7) NC 133 south of NC 211 has been labeled on the vicinity map on page 01.0 SEP 2 0 206 r JW HILTGGINS rip-irneerinp-r 8r- Surveviri—o- Inc. P.O. Box 11351, Southport, NC 28461 PH: 910-278-1226 Fax: 866-597-4820 We are providing two (2) copies of revised sheet 01.0 and sheet 01.1 along with (2) copies of pages I & 4 of the Stormwater Management Permit Application Form. Additionally we are providing (4) copies of page 4 of the Infiltration Trench Supplement with the (2) sets of pages 1-3 for the Infiltration Trench Supplement you sent us for your continued review and approval. Please contact us if you have any further questions or comments. Thank you for your assistance on this project. Sincerely, J W Huggins Engineering & Surveying Inc. J W Huggins, P.E. ,i - J W Huggins Engineering Inc. P.O. Box 11351, Southport, NC 28461 Stormwater Narrative Monday, August 7. 2006 Narrative for the development of a building supply at 4255 Long Beach Rd. in Southport, NC. Drainage Area 1 The stormwater from the site will be collected by sloping the lot from the property lines to the center at a minimum of 1/2%. At the center of the lot there is a StormTech SC-740 Chamber System. This System is tied together by 3' x 3' x 6' deep drop inlets with 12" and 2' diameter pipes. The stormwater will be collected for storage and infiltration in the StormTech SC-740 chambers. Each chamber has 81.6 cubic feet of stormwater storage. The system consists of 235 chambers for a total of 19,176 cubic feet of storage. This will contain all of the stormwater from the site. This design allows for all of drainage area 1 to be impervious. Additionally, this design is for a 1.57, 24-hour design event to be contained and furthermore, 3" of storage is obtained so the "no overflow" requirements are met. Drainage Area 2 The stormwater from the roof surface will be collected into the gutter system and piped to 3' x 3' x 3' #57 rock boxes for storage and infiltration; these rock boxes are then piped with 8" pipe to the second StormTech SC-740 system. The impervious surfaces outside of the roof areas will have a 1 % slope to the edges of the surface. At the edge of the lot there is a StormTech SC-740 Chamber System. This System is tied together by 3' x 3' x 6' deep drop. inlets with 12" pipes. The stormwater will be collected for storage and infiltration in the StormTech SC-740 chambers. Each chamber has 81.6 cubic feet of stormwater storage. This system consists of 44 chambers for a total of 3590 cubic feet of storage. This design allows for 6,000 square feet of building and 8200 square feet of impervious surfaces. All of the stormwater will be contained on the site in the storage and infiltration system. Additionally, this design is for a 1.5", 24-hour design event to be contained and furthermore 3", of storage is obtained so the "no overflow" requirements are met. J W Huggins Engineering Inc. P.O. Box 11351, Southport, NC 28461 Stormwater Narrative Monday, August 7, 2006 Pre Construction conditions were determined using TR-55 calculations. The Project is divided into 2 Drainage areas as follows: Draingge Area 1: Bann Area 76000 sgft 1.744 Acre Imperious Area 76000 sgit 1.744 Acres Impervious Percent 100% Drainage Area 2: Basin Area 24000 sgft 0.551 Acre Impervious Area 8051 soft 0.185 Acres Impervious Percent 58.59/o See Attached Tc and CN calculation sheet for Total TC, Storage Coefficient, and Weighted CN. See Attached spreadsheets for Pre -Construction Intensities and Flow rates Page 1 of' 1 North Carolina Elaine F Marshall i EPARTMENT OF'THE Secretary . SECRETARY OF STATE Corporations •Corporations Home •Important Notice °Corporations FAQ •Tobacco Manufacturers •Dissolution Reports •Non -Profit Reports °Verify Certification •Online Annual Reports •KBBE B2B Annual Reports Links °Secretary Of State Home •Register for E-Procurement *Dept. of Revenue Legislation *1999 Senate Bills °2001 Bill Summaries °Annual Reports 1997 "Corporations 1997 Search °By Corporate Name °For New Corporation *By Registered Agent Online Orders *Start An Order •New Payment Procedures Contact Us °Corporations Division "Secretary of State's web site Print *Printable Page PO Box 29622 Raleigh, NG 27626-0622 (919}807-2000 Date: 9/7/2006 Click here to: View Document Filings I Print apre-populated Annual Report Form i Annual Report Count I Fil an Annual Report I Corporation Names Name Name Type NC Brian Keith Keesee Legal Construction Inc Business Corporation Information SOSID: Status: Date Formed: Citizenship: State of Inc.: Duration: Registered Agent Agent Name: Registered Office Address Registered Mailing Address: Principal Office Address: Principal Mailing Address 0615806 Current -Active 1/10/2002 Domestic NC Perpetual Keesee, Brian Keith 226 Northeast 63rd Street Oak Island NC 28465 226 Northeast 63rd Street Oak Island NC 28465 226 Northeast 63rd Street Oak island NC 28465 226 Northeast 63rd Street Oak Island NC 28465 Stock Class Shares No Par Value Par Value Common 10000 Yes NIA For questions or comments about the North Carolina Secretary of State's web site, please send e-mail to Webmaster, http:l/www.secretary.state.nc.us/Corporations/Corp.aspx?Pltemld=5409128 9/7/2006 SOS ID: 0615806 Date Filed: 4/18/2005 12:15:01) PM Elaine F. Marshall North Carolina Secretary of State i 479 Business Corporation Use this form only it 2005108 09041 -t North Carolina Annual Report AnnualContactRaport forme Liability Partnerships, and Lirnited Liability Companies. Name of Corporation: BRIAN KEITH KEESEE CONSTRUCTION INC State of Incorporation: NC Fiscal Year Ending: 12 31 04 Mon1h / Day / Year Secretary of State Corp. ID Number: 0 615 8 0 6 Federal Employer la Number: 010585968 H this is the Initial annual report filing, you must complete the entire form. If your business corporation's information has not changed since the previous report, check the box and complete Llne 7 only. I. Registered agent & registered office street address: (Must be a North Carolina Address) Name; Street Address: My. Stets. Zip Code: County: 2. Mailing address if different from street address: Mailing Address: City, State, Zlp Code.. 3. N registered agent changed, signature of new agent: (signature constitutes consent to the appointment) 4. Enter principal office address and tetephone number here: Street Addre= Chy, State, Zip Code: Telephone: 5. Brieftr describe the nature of business: 6. Enter name, title, and business address of principal officers here: Complete Form CD-479A to list additional principal officers Name: Title, Address: City: State: Zip: Name: Titta: Address: C' : State: Zip: Name: Address: Title: 7. C Of report / ? v , State: completed by all corporations). S1911ture {Form imut 59 signed by an officer or corporation) �4A�' Yee Sce Type or Print name its — Title TO : 84591-- " SOSID: 615806 22 007 5 17 i Date Filed: 1/10/2002 4:00 PM State of North Carolina Elaine F. Marshall Department of the Secretary of State North Carolina Secretary of State ARTICLES OF INCORPORATION Pursuant to §55-2-02 of the General Statutes of North Carolina, the undersigned does hereby suhmit these Articles of Incorporation for the purpose of forming a business corporation. 1. The name of the corporation 2. The number of shares the corporation is authorized to issue is: Theseesshares shall be: (check either a orb) a, A! all of one class, designated as common stock; or b—divided into classes or series within a class as provided in the attached schedule, with the information required by N.C.G.S. Section 55-6-01. 3. The street address and county of the initial registered office of the corporation is: Number and Street City, State, Zip Code d T S L )I.%J L> ry C 2- k q t.5 - -County 111JS�+1 ]rCK 4. The mailing address if different from the street address of the initial registered office is: 5. The name of the initial registered agent is: i )Srl9� 6. Any other provisions, which the corporation elects to include, are attached. 7. The name and address of each incorporator is as follows: 22t� ;40leTNl5*SY- 'G39n Sr rS kYlA t A G ?-N Lr 8. These articles will be effective upon filing, unless a date and/or time is specified: This the —L-5rday of LrA4 tA At-1 20-0-1,-- AND NOW ON l` Eden)f^mot Type or Print Name and Title NOTES: 1. Filing fee is S125. This document and one exact or conformed copy of these articles must be filed with the Secretary of State. (Revised January 2000) (Form 8-01) CORPORATIONS DIVISION P. 0, BOX 29622 RALEIGH, NC 27626-0622 15 SOS] D: 0615806 Date Filed: 7/21/2003 10:25:00 AM Elaine F. Marshall North Carolina Secretary of State 2003 146 00067 CD-479 (45) Business Corporation Use this form only V y 7•e1 North Carolina Annual Report Contact the N.C. Secr 2 9 s Annual Report form fail Liability Partnerships, and Limited Liability Companies. Name of Corporation, BRIAN KEITH KEESEE CONSTRUCTION INC Slate of Incorporation. NC Secretary of State Corp. 10 Number: 0 615 8 06' Fiscal Year Ending: Federal Employer ID Number: 010585968 If this Is the Initial annual report tiling, you must complete the entire form if your business corporation's information has not changed since the previous report, check the box and complete Line B only. 1. Registered agent & registered office mailing address Agora: BRIAN KEIT1•I KEESEE Mailing Address: 226 NORTHEST 63RD ST OAK ISLAND NC 28465 2. Street address & county of registered office Street Address: 226 NORTHEAST 63RD ST County: BRUNSWICK 3. If registered agent changed, signature of now agent: {antra comtltutes cement to lh• appointment) 4. Enter principal office address here: 226 NORTHEAST 63RD ST OAK ISLAND NC' 28465 5. Enter principai office telephone number here: i�,� •�n'Cj, D�� Q fi. Enter name, title, and business address of principal oir"m here; Complete Form CD-479A to list additional principal officers �iAV'o - Mon Day/Yaar --* 0 Name: BRIAN KEITH KEESEE Title: PRESIDENT Address: 226 NORTHEAST 63RD ST City:. OAK I S LAND state: NC _ zip: 28465 Name: rule: Address: Cam: State: Zip: Name: Title: Address: City; State: Zip: 7. Briefly descrihe the nature of business: 0 RU ION OF ESIDENTIAL HOUSES B icatio 41 po ust be completed by all corporations 4Aki� lq turn ( orm t be argnad by an of flwr or rarpuauan) Date BRIAN KEITH KEESEE PRESIDENT _�� � e!'Pa llilf#Ifll ill 111111111 Jill 111 1111111111111111111111 Michael F. Easley, GUVemOr �o�oF w A r�9QG July 31, 2006 Mr. Brian K. Keesee BKK Construction, Inc. 8300 E. Oak Island Drive Oak Island, NC 28465 Subject: Request for Additional Information Stormwater Project No. SW8 060742 Oak Island Building Supply Brunswick County Dear Mr. Keesee: William G. Ross Jr., Secretary North Carolina Department of Fnvironment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality The Wilmington Regional Office received a Stormwater Management Permit Application for Oak Island Building Supply on July 27, 2006, with a scheduled Express Review date of July 27, 2006. The check for the application fee was only written for $2,000, whereas the project is high density, and requires a $4,000 fee. Check #1800 for $4,150.00 was received on July 31, 2006. A preliminary review of the submitted information has determined that the application is not complete. The following information is needed to continue the stormwater review: tI%1. Please provide proposed grading in the form of actual finished grade spot elevations and contours. Flow arrows depicted the direction of drainage are not sufficient. 2. Please report your title within the corporation in Section 1.2 of the application. Only a person of at least the level of vice president in the corporation may sign the application and supplements. 3. Please have .the consultant redraw the plans to an acceptable engineering scale. The current scale of 1132" = 1' is not acceptable. The smallest scale on my architect's scale is 3132" = 1'. ,f 4. The dimensions shown on the plans for Trench #1 do not appear to be correct. Please check and revise as necessary. Based on the provided Stormtech plan and section details, a minimum trench length of 236 feet and a minimum trench width of 48' is required to accommodate the 233 proposed Stormtech units for Trench #1 in the proposed configuration. Based on the dimensions shown on the plans of 73'-10" and 97'-6", only a total of 171 feet of trench is provided. The width of Trench #1 is not specified on the plans. ✓5. Please provide accurate dimensions for the building, parking, sidewalk and storage areas. i/ 6. The Stormtech plan details are not matching up very well with the proposed configuration of the trenches. 7. Please add the number of Stormtech units being proposed for each Trench, and the individual volume for a single Stormtech SC-740 unit (45.9 cubic feet, One without stone?) Np�(tthtCarolina Na&ra!!y North Carolina Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Phone (910) 796-7215 Customer Scrvice Wilmington Regional Office Internet: www,ncwaterquality.org Fax (910)350-2004 1-877-623-6748 An Equal OpportunitylAffirmative Action Employer — 50% Regcledll0% Post Consumer Paper Mr. Keesee July 31, 2006 Stormwater Application No. SW8 060742 8. The supplement forms are geared toward the more traditional gravel trench with perforated piping however, they can be adapted for the Stormtech system. Please report the trench length and width on each supplement. The consultant has indicated that this varies, but I disagree. Based on the proposed configuration, a finite trench length and width can be established. 9. The specifications for Stormtech indicate that the 81.6 cubic feet of volume per unit for the SC-740 includes 12" of stone. Does this value include the 6" of stone above the unit as well? 10. Please sign, seal and date the calculations. 11. Please delineate the individual post -development drainage area for each of the two proposed trenches. 12. Please provide a vicinity map on the plans and show the nearest intersection of two major roads. A major road is any 1, 2 or 3 digit NC, US or interstate highway. Ideally, the vicinity map should be geared toward driving to the site from Wilmington. 13. Due to the insufficiency of this application, the Division is requiring a $1,000 resubmittal fee. Please note that this request for additional information is in response to a preliminary review. The requested information should be received in this Office prior to August 11, 2006, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you need additional time to'submit the information, please mail or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter. The request must indicate the date by which you expect to submit the required information. The Division is allowed 90 days from the receipt of a completed application to issue the permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. Please reference the State assigned project number on all correspondence. Any original documents that need to be revised have been sent to the engineer or agent. All original documents must be returned or new originals must be provided. Copies are not acceptable. If you have any questions concerning this matter please feel free to call me at (910) 796-7335.' Sincerely, Linda Lewis Environmental Engineer ENBlarl: S:IWQSISTORMWATERIADDINF0120061060742.ju106 cc: J.W. Huggins, P.E. Linda Lewis Page 2 of 2 ADS Products - Bio-Diffuser Leaching Chambers Page f of 1 Phone, Fax or E-mail us with product questions or comments about our website. Get ADS Sales/Pricing Information LJANGUAGE I_1D1OMA Cambie al espaAol See related StormTech Chambers Technical Data Product -related questions? See our Product/Technical FAQs 1 SC-740TM chambers ;.r The StormTech SC-740T1' Chamber optimizes storage volumes in relatively small footprints. By providing 2.2 ft3/ft2 (minimum) of storage, the SC-740TM chambers can prevent excessive excavation, backfill and associated costs. ' StormTech chambers have been subjected to advanced in -ground testing protocols and high-level industry expert review. They have been evaluated to support HS- 20 live loads following current AASHTO procedures for loads, structural capacity and factor of safety when installed per StormTech's Chamber Installation Instructions. StormTech chambers are molded from Polypropylene resin, which is inherently resistant to environmental stress cracking and chemicals typically found in stormwater runoff. . Click here to view the technical drawing with the specifications of the SC-740TM Chamber. Nominal Chamber Specifications Chamber Size (W x H x Installed I-) 51.0" x 30.0" x 85.4" Chamber Storage 45.9 ft3 Chamber Wei ht 74.0 Ibs Minimum Installed Storage 74.9 ft3 Home I About ADS I Job Opportunities I Sales Information I News I Contact ADS 4640 Trueman Boulevard, Hilliard, OH 43026 Tel: 800-821-6710 Copyright @ 2002 Advanced Drainage Systems. All rights reserved. Q Send I.... -...... ...................... ..* uci i E P� . ,.r : Pha W1s The inert pn corrugated I polyethylene it to handle leachate sol ranging in p to 14. From the Gi http://www.ads-pipe.com/us/en/products/sc740chamber,shtmi 7/28/2006 OMS Viewer i Page 1 of I d - I r r r r r r tttp.Hgis.brunsco.net/mapfi-ame.htm s/7/2ao6 { STATi OF ppll7H CAROLAA - o—u �n IMF —tn*vrnR,'I.CA110411N ¢i1•n p�pBif O► lIR M1�1d li _ 1 1 i ,1, , � -� I 1 •� + it--� _I r y I i � � A111Yd a hir rIWA,w r.w 0=1 1/Ian y� w.r......•- 'i4 5cple Rand McNally - Get a Map .. . Page 1 of'] Back I ,vww.randmcnally.com � I 11 11 11 11 I I 11 I I Use the print feature in your browser to print this page. 4255 Long Beach Rd SE Southport, NC 28461-8626 Sw�ny Pn:i� 1!^tart' C an � 'rmuna: s b a T ^�v A Calhoun N SE y �`s�Lrey.+,,tiya4 Q� ,r+T gv_ Asb o ve ShtjlardRd$ Sea pin �F v 5t. l � ti t-•° Villa Nova LD Sr Sonnat Sumils Di SE L s Ahr Robert Ruadr I>r ':' �rc'4'•< �ypi 4i1port Rd SE X42ii LMW 1 *M*.#A 3! r v Pa* Av E,z o, ;• � _ � buns"South `�,n_ Scupper Run 5E Harbour �4rQ�gt 11� ooFf li S 4 Southport 4 il c'• 11a T a s ' IA km o U' m Caswell (112nDS Rand Nt Nary $ Company (UM-0Q NAvTEQ Beach IFind it in the 2006 Road Atlas *page 75, grid section K-13 All rights reserved. Use subject to license. II Qe 2006 randmcnally.com inc � I � I 11 Cap,- >eu: k: ve- ... , —.73 II http : //www. randmenal ly .com/rmc/directions/dirPrintMap. j sp?co l--color&n=&A=;4255+Long+Beach+Rd+... 8/7/2006 1. � 1 Brian Keesee Construction Building Supply Stormwater Storm'Tech Design Data Prepared by: .IW Huggins P.E. Engineering Inc. PO Box 11351 Southport NC 28461 910-278-1226 I a McmMaRW OMMOO I Table 5 and Table 6 provide incremental storage volumes for SC-310 and SC-740 chamber systems. This infor- mation may be used to calculate a detentionlretention system's stage storage volume. Product Specifications: 1. 1, 2.2, 2.3, 2.4 and 2.6 TABLE 5 - SC•310 Incremetrtal Storage Volumes Per Chamber Assumes 40% Stone Porosity. Calculations are Based Upon a 6-inch Stone Base Under the Chambers. BD kEftaU (W) RINU Ord MwCap 28_ 31.00 27 _14.70 _ 14.70 - 30.21 26 Slone 14.70 29.42 -_ 28.63 �- 25 Cover 14.70 � 24 _ 14.70 _ 27.84 - 23 Y 14.70 27.05 _ 22 r_^_ _ 14.70 �- 26.26 21 14.64 _ 25.43�_ 20 14.49 _ _ 24.54 19 14.22 23.58 18 - _ -R - -13-68 _ 22.47 -, .17 _ 12.99 2125_ _ 16 12-17 19.97 j 15 11.25 18.62_ 10 23 _i_ .�..... 17.22 _ T 13 9.15 15.78 12 7.99 14.29 11 6-78 _ 12-77 10 -- 5.51 11.22 9 4.19 _ 9.64 r-- 8 _ * 2.83 �y�-.-_-- 8.0_3 7 1.43 6.40T--J 6 0 4.74 3.95 5 0 4 Stone_0 - 3.16 _ 3 Foundation 0 0 _ 2.37 2 1.58 1 0 0.79 Note. Add 0.79 cu. fc of storage for each additional inch of stone foundation. TABLE 6 - SC-740 Incremental Storage Volumes Per Chamber Assumes 40% Stone Porosity. Calculations are Based Upon a 6-inch Stone Base Under the Chambers. O0 tf o a er Cumu ailve lal Sysle n n yste n Chamee Cumulal e Stange it Slo age 11 42 45.90 74.90 _ 41 ~. 45.90 73.77 _ 40� -- Stone 45.90 72.64 39 Cover 45.90 71.52 38 G_ 45.90 _ 70.39 T _ 36 35 45.90 68.14 _ 66.98_ T 34� _45.85 45.69 65.75 i 45.41 f 64.46 _33 T 32_ 31 44.81 44.01 62.97 61.36 30 43.0_ 6 59.66 r _ _ 29 _ 28 41.98 40.80 57.89 5605 27 26 39.54_ 38.18 _ _ . 54.17 52.23 _ 425 T 36.74 50.23 24 �r 23 - 35.22 33.64 48.19 46.11 22 31.99 44.00_� 21 30.29 1 41.85 19 -� 26.74 24.89 i 37.47__ _ 35.23 I _- 17 J 16 23.00 21.06 32.96 30.68 15 19.09 T28.36,�� 14 17.08 26.03 _ 13 15.04 23.68 12 12.97 ii -inns 1R49 ! 10 _ 8.74 16.51 9 _ 6.58 14.09 8 4.41 11.66 7 - 6 2.21 0 9.21 � 6.76 5.53 I 5- - 0 -�� 4 3 Stone 0 Foundation 0 0 4.51 3.38 2 1 2.25 0 1.13 _ _ Note: Add 1.13 cu. ft of storage for each additional inch of stone foundation. 14 Call StormTech at 888.892.2694 or visit our website at www.storFntech.com for technical and product information. L' 0-0 OUOUMt OMRt gu For quick calculations, refer to the Materials Worksheet on StormTech's website at www.stormtech.com. 10.1 SYSTEM SIZING The following steps provide the calculations necessary to size a system. The worksheet on page 17 itemizes these calculations and costs. If you need assistance determin- ing the number of chambers per row or customizing the bed configuration to fit a specific site, call StormTech's Technical Services Department at 14888-892-2694. 1) Determine the amount of storage volume (Vs) required. It is the design engineer's sole responsibility to deter- mine the storage volume required by local codes. TABLE 7 — Storage Volume Per Chamber Bare �— Chamber and Stone 'Chamber, Stone Foundation Depth Storage 1 6"- 12"-- 1r SlormTech SC-740 45.9 74.9 81.7 88.4 SlormTech SC-310 14.7 31.0 35.7 T 40-4 Note: Storage volumes are in cubic feet per chamber. Assumes 40% porosity for the stone plus the chamber volume. 2) Determine the number of chambers (C) required. To calculate the number of chambers needed for adequate storage, divide the storage volume (Vs) by the volume of the selected chamber, as follows: C = Vs / Volume per Chamber 3) Determine the required bed size (S). To find the size of the bed, multiply the number of chambers needed (C) by either: StormTech SC-740 bed area per chamber = 33.8 it' StormTech SC-310 bed area per chamber = 23.7 ft' S = (C x bed area per chamber) + (1 foot x bed perimeter in feet) NOTE• It is necessary to add one foot around the perimeter of the bed for end caps and working space. 4) Determine the amount of stone (Vst) required. TABLE 8 - Amount of Stone Per Chamber in Tons -- ---- -- Stone Foundation Depth StormTech SC-740 3.8 (2.8 yd) 4.6 (3-3 yd') 5.5 (3.9 yd') StormTech SC-310 2.1 (1.5 yd') 2.7 (1.9 yd') : 3.4 (2.4 yd') Note: Assumes 6 inches of stone above, and between chambers. To calculate the total amount of washed, crushed angu- lar stone required, multiply the number of chambers (c) by the selected tons of stone from Table B. NOTE. Washed, crushed angular stone is also required around the perimeter of the system. 5) Determine the volume of excavation (Ex) required. 6) Determine the area of filter fabric (F) required. TABLE 9 — Volume of Excavation Per Chamber Y -- - Stone Foundation Depth StarmTech SC-740 5.5 6.2 6.8 StormTech SC-310 2.9 3.4 T3.8 Note: Volumes are in cubic yards per chamber. Assumes 6 ruches of separation between chamber rows and 18 inches of cover. The vol- ume of excavation will vary as the depth of the cover increases. Each additional foot of cover will add a volume of excavation of 1.3 cu. yds. per SC-740 and 0.9 cu. yds. per SC-310 chamber. The bottom and sides of the bed and the top of the angular stone must be covered with a non -woven geot- extile (filter fabric) that meets AASHTQ M288 Class 2 requirement. The area of the sidewalls must be calculat- ed and a 2-foot overlap must be included where two pieces of filter fabric are placed side -by -side or end -to - end. Geotextiles typically come in 15 foot wide rolls. 7) Determine the number of end caps (Ec) required. Each row of chambers requires two end caps. Ec = number of rows x 2 16 Call StormTech at 888.892.2694 or visit our website at www.storrntech.com for technical and product information. . .�L1111 [l llilal Vv [111 YI111Y It,- . — - - _ _ 1 1W MARKETS WE SERVE F, I StC,rI':"1 E:Ci i f:;S� "Dt1"1pai :>on Phone, Fax or C-mail us with product CUSTOMIER SERVICE questions or PLEASE NOTE. This site calculator utilizes a 40% porosity within the stone. comments about our website. Get ADS Sales/Pricing Information LANGUAGE / I0iO AA Cambie al e-spanol RFI�ATFE] INFC1RdA'if"10,; A`.1 W,. See related -� StormTech Chambers Technical Data View Technical Data by Mafket ,." View Technical Data by DatA.Type View Technical Data by ProdUcA Type Technical questions? See cur Product/Technical FAQs - Site Calculator Enter the Required Storage Volume and select a StormMaster system and the calculator will approximate the total system size and cost needed. Required Storage Volume: 3512 ft3 Calculate StormTech Systems: SC - 740 FTR —es et StormTech Volume per Chamber: 81.6 CF w112" of stone below Number of Chambers Needed: 44 Required Bed Size: " 1635 92 ftz Quantity of Stone. * 159.72 Yds3 222.64 Volume of Excavation: ' 304.92 Yds3 Area of filter fabric: ` 199.95 Yds2 Quantity Cost, Total Chambers: 44 $ 185 / unit"` $ 8,140.00 Stone. 222.64 $ 12.00 / ton $ 2,671.68 Excavation: 304.92 $ 5.00 / yard $ 1,524,60 Filter Fabric: 199.95 $ 0.50 / yard $ 99 98 ,Call 1-888-296-5367 for estimated chamber pricing Subtotal 5 12,434.00 Cost per ft3 $ 3.54 . includes 10% overage for bed perimeter Tons For general estimate purposes only. Contact Stormtech for costs on specific projects and associated variables. foes not reflect changes in geographical costs or contractors overhead, profit and other miscellaneous expenses. "Chamber costs may not be inclusive of shipping. L,.._.11.,..,. "A' „;. " ,.,,/110/,,,,/IeWlinirraiI/ellrrralr c1111111 7/24/2006 1101 ILI i t-%ii'=CIL Yauiy - - — ' K MARKETS WE SERVE C (:) ,.'J. Cc I'.,...I !")I.- r Phone,.F?x or E-mail us with product CUSTOMER SERVICE questions or PLEASE NOTE. This site calculator utilizes a 40% porosity within the stone. comments about our website. Site Calculator Enter the Required Storage Volume and select a StormMaster system and the Get ADS calculator will approximate the total system size and cost needed. Salesi Acing Information LANGUAGE I IDIOMA Cambie al..espgool See related StormTech Chambers Technical Data 1 View Technical Data by Market View Technical Data by Data Type View Technical Data by Froduct Type Technical questions? See our Product/Technical FAQs Required Storage Volume: 19000 ft3 Calculate StormTech Systems: SC - 740 Reset StormTech Volume per Chamber: 81 6 CF w112" of stone below Number of Chambers Needed: 233 Required Bed Size: ' 8662.94 ft 2 Quantity of Stone: " 845.79 Yds3 1178.98 Volume of Excavation: " 1614.69 Yds3 Area of filter fabric' " 1058,8 Yds2 Quantity Cost, Total Chambers: 233 $ 185 1 unit— $ 43,105,00 Stone: 1178,98 $ 12.00 1 ton $ 14.147.76 Excavation; 1614 69 $ 5.00 1 yard $ 8,073 45 Filter Fabric: 1058.8 $ 0.50 I yard $ 529.40 'Call 1-888-296-5367 for estimated chamber pricing. Subtotal $ 65.854.00 Cost per ft3 $ 3.47 * includes 10% overage for bed perimeter Tons For general estimate purposes only. Contact Stormtech for costs on specific projects and associated variables. Does not reflect changes in geographical costs or contractors overhead, profit and other miscellaneous expenses —Chamber costs may not be inclusive of shipping. July 24, 20 II Z, Sear, r 1.....•1l....,......,1.. ...«.r., n,�.�z/,iclr.•nit�?/'i�i9u`alIC11F'!`�l(' 41111111 July 20, 2006 J.W. Huggins Engineering, Inc. Post Office Box 113 61 Southport, North Carolina 28461 Attention: Mr. Avram Adelman, EIT Reference: Double Ring Infiltrometer Testing 4255 Lang Beach Road Oak Island, North Carolina S&ME Project No. 1061-06-236D Dear Mr. Adelman: RECEIVED JUL. 2 l 2006 DWQ c= >PROJ# 5wgb(rD�4'L In accordance with S&ME Proposal 235-06 dated June 29, 2006, S&ME personnel have recently conducted double -ring infiltrometer testing of the surficial soils at the subject site at the approximate locations shown in Figure 1. Specifically, our representatives performed the following work items: Advanced one hand-augered boring at the site in order to visually classify the in - place soils. The hue and chroma of the recovered soil samples were compared to a Munsell Soil Color Chart. 2. Conducted one double -ring infiltrometer test at a depth of 18 inches below the existing ground surface. This testing was conducted in general accordance with American Society for Testing and Materials (ASTM) procedure D-3385 entitled, "Infiltration Rate of Soils in Field Using Double -Ring Infiltrometer". Based on our field classifications of the excavated soils at the hand -angered boring location, the in -place soil consists of sands with varying amounts of silt which extended to the maximum completed boring depth of 76 inches below the existing ground surface, Water was encountered in the borehole at a depth of 71 inches below the existing ground surface. The site water level will fluctuate with climatic and seasonal conditions, however, and may be higher or lower at other times of the year. S&ME, INC. / 6409 Amsierdarn Way, Building B3 / Wilmingion, NC 213405 / p 910.799.9945 f 910.799.9958 1 www.smeinc.cam J.W. Huggins Engineering, Inc. S&ME Job Number 1061-06-236D July 20, 2006 Page Two The average infiltration rate at the test location was 14.8 inches per hour. A summary of the field test results is presented in Tables 1 and 2. S&ME appreciates the opportunity to provide our services during this phase of the project. Should you have any questions after reviewing this letter, or if we can be of additional assistance, please do not hesitate to contact us at your convenience. Sincerely, S&ME, INC. Paul A. V Environmental Professional PAURGIVUins Attachments Randy Martin, P.E. Branch Manager Depth Location Inches 1 0-15 15-45 45-76 TABLE 1 Hand Auger Borings Munsell Soil Descriptions Oak Island Building Supply 4255 Long Beach Road Oak Island, North Carolina S&ME Project No. 1061-06-236D Hue Value/Chroma Soil Description 2.5 Y 511 Gray slightly silty medium to fine SAND 2.5 Y 4/4 Olive brown slightly silty medium to fine SAND 2.5 Y 7/2 Light gray slightly silty medium to fine SAND Water was encountered at a depth of 71" below the existing ground surface. According to the Soil Survey of Brunswick County, the area wherein HA-1 was advanced consists of the Kureb soil series, which has a reported seasonal high water table of 6 feet below land surface. TABLE 2 Double Ring Infiltrometer Testing Oak Island Building Supply 4255 Long Beach Road Oak Island, North Carolina S&ME Project No. 1061-06-23 6D Location: 1 Date of Test: July 13, 2006 Depth of Test Below Site Grade: 18 inches Depth of Water in Rings: 3 inches Depth to Water: 71" Average Infiltration Rate: 14.8 inches per hour High Water Table: >6 feet below land surface* Soil Series. Kureb* Inner Diameter of Inner Ring: 11'/4 inches Inner Diameter of Outer Ring: 22'/z inches Note: *As interpolated from the "Soil Survey of Brunswick County" prepared by the United States Department of Agriculture Soil Conservation Service LEGEND Note: Site plan drawing provided to S&ME by ® Approximate J.W. Huggins Engineering personnel. Test Location SCALE: NOT TO SCALE HAND -AUGER BORING AND DOUBLE FIGURE RING INFILTROMETER TEST LOCATION NUMBER CHECKED BY: PAM OAK ISLAND BUILDING SUPPLY -rM 4255 LONG BEACH ROAD DRAWN BY: JNS ENGINEERING • TESTING OAK ISLAND, NORTH CAROLINA _ ENVIRONMENTAL SERVICES DATE: 7-6-06 1 JS&ME PROJECT NUMBER: 1061-06-236D