HomeMy WebLinkAboutSW8051117_CURRENT PERMIT_20051219STORMWATER DIVISION CODING SHEET
POST -CONSTRUCTION PERMITS
PERMIT NO.
SW �S�l
DOC TYPECURRENT
PERMIT
APPROVED PLANS
❑ HISTORICAL FILE
❑ COMPLIANCE EVALUATION INSPECTION
DOC DATE
/°�
YYYYMMDD
=OF �NAT, 9- Michael F Easley, Governor
1} O G William G Ross, Jr, Secretary
North Carolina Department of Environment and Natural Resources
Alan W Klimek, P E Director
Division of Water Quality
December 19, 2005
Mr Perry Bradford Dawson
Senior Vice President
Waccamaw Bank
110 North Powell Blvd , P O Box 2009
Whiteville, NC 28472
Subject Stormwater Permit No SW8 051117
Waccamaw Bank
High Density Project
Brunswick County
Dear Mr Dawson
The Wilmington Regional Office received a complete Stormwater Management Permit
Application for Waccamaw Bank on December 12, 2005 Staff review of the plans and
specifications has determined that the project, as proposed, will comply with the Stormwater
Regulations set forth in Title 15A NCAC 2H 1000 We are forwarding Permit No SW8 051117
dated December 19, 2005, for the construction of the subject project
This permit shall be effective from the date of issuance until December 19, 2015, and shall be
subject to the conditions and limitations as specified therein Please pay special attention to
the Operation and Maintenance requirements in this permit Failure to establish an adequate
system for operation and maintenance of the stormwater management system will result in
future compliance problems
If any parts, requirements, or limitations contained in this permit are unacceptable, you have
the right to request an adjudicatory hearing upon written request within thirty (30) days
following receipt of this permit This request must be in the form of a written petition,
conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of
Administrative Hearings, P O Drawer 27447, Raleigh, NC 27611-7447 Unless such demands
are made this permit shall be final and binding
If you have any questions, or need additional information concerning this matter, please
contact Paul Bartlett, or me at (910) 796-7215
Sincerely
Edw'B�eC
Regional Supervisor
Surface Water Protection Section
ENBlptb S IWQSISTORMWATERIPERMIT1051117 dec05
cc Robert P Balland, El, WK Dickson & Co, Inc
Delaney Aycock, Brunswick County Building Inspections
Jeff Phillips, Brunswick County Engineering
Paul T Bartlett, P E.
l ilmington--RegionalzGffice=
Central Files
North Carolina Ninon of Water Quality 127 Cardinal Dnve Extension Phone (910) 796 7215 Customer Servicel 877-623 6748
Wilmington Regional Office Wilmington NC 28405 3845 FAX (910} 350 2004 Internet h2o enr state nc us One
NorthCarohna
An Equal OpportumtylAffrmative Action Employer— 50%q Recycied110%a Post Consumer Paper Naturally
State Stormwater Management Systems
Permit No SW8 051117
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
DIVISION OF WATER QUALITY
STATE STORMWATER MANAGEMENT PERMIT
HIGH DENSITY DEVELOPMENT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of
North Carolina as amended, and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Perry Bradford Dawson and Waccamaw Bank
Waccamaw Bank, 4945 Southport -Supply Road, Southport
Brunswick County
FOR THE
construction, operation and maintenance of a wet detention pond in compliance with
the provisions of 15A NCAC 2H 1000 (hereafter referred to as the "stormwaterrules'�
and the approved stormwater management plans and specifications and other
supporting data as attached and on file with and approved by the Division of Water
Quality and considered a part of this permit
This permit shall be effective from the date of issuance until December 19, 2015, and
shall be subject to the following specified conditions and limitations
I DESIGN STANDARDS
1 This permit is effective only with respect to the nature and volume of stormwater
described in the application and other supporting data
2 This stormwater system has been approved for the management of stormwater
runoff as described in Section 16 on page 3 of this permit The stormwater
control has been designed to handle the runoff from 42,974 square feet of
impervious area
3 The tract will be limited to the amount of built -upon area indicated on page 3 of
this permit, and per approved plans There is no allotment for future built -upon
area at the site
4 All stormwater collection and treatment systems must be located in either
dedicated common areas or recorded easements The final plats for the project
will be recorded showing all such required easements, in accordance with the
approved plans
5 The runoff from all built -upon area within the permitted drainage area of this
protect must be directed into the permitted stormwater control system
Page 2 of 7
State Stormwater Management Systems
Permit No SW8 051117
6 The following design criteria have been provided in the wet detention pond and
must be maintained at design condition
a DrainaArea, Acres
gnslte, ft
Offsite, ft2
b Total Impervious Surface,, ft2
Onsite Buildings, It
Onsite Parking, ft 2
Onsite SYewalks, ft
Offsite, ft
c Design Storm, inches
d Pond Depth, feet
e TSS removal efficiency
f Permanent Pool Elevation, FMSL
g Permanent Pool Surface Area, ft2
h Permitted Storage Volume, ft3
i Temporary Storage Elevation, FMSL
t Controlling Orifice
k Permitted Forebay Volume, ft3
1 Receiving Stream/River Basin
m Stream Index Number
n Classification of Water Body
II SCHEDULE OF COMPLIANCE
1 26
46,886
8,000
42,974
6,331
27,052
1,591
8,000
10
40
90%
320
4,832
3,634
3288
0 75" 0 pipe
2,265
Jump and Run Creek 1 Cape Fear
18-88-9-3-2
"SC, Sw"
1 The stormwater management system shall be constructed in its entirety,
vegetated and operational for its intended use prior to the construction of any
built -upon surface
2 During construction, erosion shall be kept to a minimum and any eroded areas of
the system will be repaired immediately
3 The permittee shall at all times provide the operation and maintenance
necessary to assure the permitted stormwater system functions at optimum
efficiency The approved Operation and Maintenance Plan must be followed in
its entirety and maintenance must occur at the scheduled intervals including, but
not limited to
a Semiannual scheduled inspections (every 6 months)
b Sediment removal
c Mowing and revegetation of slopes and the vegetated filter
d Immediate repair of eroded areas
e Maintenance of all slopes in accordance with approved plans and
specifications
f Debris removal and unclogging of outlet structure, orifice device, flow
spreader, catch basins and piping
g Access to the outlet structure must be available at all times
Page 3 of 7
State Stormwater Management Systems
Permit No SW8 051117
4 Records of maintenance activities must be kept and made available upon
request to authorized personnel of DWQ The records will indicate the date,
activity, name of person performing the work and what actions were taken
5 Decorative spray fountains will be allowed in the stormwater treatment system,
subject to the following criteria
a The fountain must draw its water from less than 2' below the permanent
pool surface
b Separated units, where the nozzle, pump and intake are connected by
tubing, may be used only if they draw water from the surface in the
deepest part of the pond
c The falling water from the fountain must be centered in the pond, away
from the shoreline
d The maximum horsepower for a fountain in this pond is 1/8 horsepower
6 The facilities shall be constructed as shown on the approved plans This permit
shall become voidable unless the facilities are constructed in accordance with
the conditions of this permit, the approved plans and specifications, and other
supporting data
7 Upon completion of construction, prior to issuance of a Certificate of Occupancy,
and prior to operation of this permitted facility, a certification must be received
from an appropriate designer for the system installed certifying that the permitted
facility has been installed in accordance with this permit, the approved plans and
specifications, and other supporting documentation Any deviations from the
approved plans and specifications must be noted on the Certification A
modification may be required for those deviations
8 If the stormwater system was used as an Erosion Control device, it must be
restored to design condition prior to operation as a stormwater treatment device,
and prior to occupancy of the facility
9 Access to the stormwater facilities shall be maintained via appropriate
easements at all times
10 The permittee shall submit to the Director and shall have received approval for
revised plans, specifications, and calculations prior to construction, for any
modification to the approved plans, including, but not limited to, those listed
below
a Any revision to any item shown on the approved plans, including the
stormwater management measures, built -upon area, details, etc
b Project name change
c Transfer of ownership
d Redesign or addition to the approved amount of built -upon area or to the
drainage area
e Further subdivision, acquisition, lease or sale of all or part of the project
area The project area is defined as all property owned by the permittee,
for which Sedimentation and Erosion Control Plan approval or a CAMA
Major permit was sought
f Filling in, altering, or piping of any vegetative conveyance shown on the
approved plan
11 The permittee shall submit final site layout and grading plans for any permitted
future areas shown on the approved plans, prior to construction
12 A copy of the approved plans and specifications shall be maintained on file by
the Permittee for a minimum of ten years from the date of the completion of
construction
Page 4 of 7
State Stormwater Management Systems
Permit No SW8 051117
13 The Director may notify the permittee when the permitted site does not meet one
or more of the minimum requirements of the permit Within the time frame
specified in the notice, the permittee shall submit a written time schedule to the
Director for modifying the site to meet minimum requirements The permittee
shall provide copies of revised plans and certification in writing to the Director
that the changes have been made
III GENERAL CONDITIONS
This permit is not transferable except after notice to and approval by the Director
In the event of a change of ownership, or a name change, the permittee must
submit a formal permit transfer request to the Division of Water Quality,
accompanied by a completed name/ownership change form, documentation
from the parties involved, and other supporting materials as may be appropriate
The approval of this request will be considered on its merits and may or may not
be approved The permittee is responsible for compliance with all permit
conditions until such time as the Division approves the transfer request
2 Failure to abide by the conditions and limitations contained in this permit may
subject the Permittee to enforcement action by the Division of Water Quality, in
accordance with North Carolina General Statute 143-215 6A to 143-215 6C
3 The issuance of this permit does not preclude the Permittee from complying with
any and all statutes, rules, regulations, or ordinances, which may be imposed by
other government agencies (local, state, and federal) having jurisdiction
4 In the event that the facilities fail to perform satisfactorily, including the creation
of nuisance conditions, the Permittee shall take immediate corrective action,
including those as may be required by this Division, such as the construction of
additional or replacement stormwater management systems
5 The permittee grants DENR Staff permission to enter the property during normal
business hours for the purpose of inspecting all components of the permitted
stormwater management facility
6 The permit maybe modified, revoked and reissued or terminated for cause The
filing of a request for a permit modification, revocation and reissuance or
termination does not stay any permit condition
7 Unless specified elsewhere, permanent seeding requirements for the stormwater
control must follow the guidelines established in the North Carolina Erosion and
Sediment Control Planning and Design Manual
8 Approved plans and specifications for this project are incorporated by reference
and are enforceable parts of the permit
9 The permittee shall notify the Division any name, ownership or mailing address
changes within 30 days
Permit issued this the 19th day of December 2005
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
f E , Director
Division of Water Quality
By Authority of the Environmental Management Commission
Page 5 of 7
State Stormwater Management Systems
Permit No SW8 051117
Waccamaw Bank
Stormwater Permit No SW8 051117 Page 1 of 2
Brunswick Count
Designer's Certification
I, , as a duly registered
in the State of North Carolina, having been authorized to observe (periodically/ weekly/
full time) the construction of the project,
(Project)
for (Project Owner) hereby state that, to the
best of my abilities, due care and diligence was used in the observation of the project
construction such that the construction was observed to be built within substantial
compliance and intent of the approved plans and specifications
The checklist of items on page 2 of this form is included 4n the Certification
Noted deviations from approved plans and specification
Signature
Registration Number
Date
SEAL
Page 6 of 7
State Stormwater Management Systems
Permit No SW8 051117
Page 2 of 2
Certification Requirements
1 The drainage area to the system contains approximately the permitted
acreage
2 The drainage area to the system contains no more than the permitted
amount of built -upon area
3 All the built -upon area associated with the project is graded such that the
runoff drains to the system
4 All roof drains are located such that the runoff is directed into the system
5 The outlet/bypass structure elevations are per the approved plan
6 The outlet structure is located per the approved plans
7 Trash rack is provided on the outlet/bypass structure
8 All slopes are grassed with permanent vegetation
9 Vegetated slopes are no steeper than 3 1
10 The inlets are located per the approved plans and do not cause short-
circuiting of the system
11 The permitted amounts of surface area and/or volume have been
provided
12 Required drawdown devices are correctly sized per the approved plans
13 All required design depths are provided
14 All required parts of the system are provided, such as a vegetated shelf,
and a forebay
15 The required system dimensions are provided per the approved plans
cc NCDENR-DWQ Regional Office
Delaney Aycock, Brunswick County Building Inspections
Jeff Phillips, Brunswick County Engineering
Page 7 of 7
OFFICE USE ONLY
Date Received Fee Paid Permit Number
State of North Carolina
Department of Environment and Natural Resources
Division of Water Quality
STORMWATER MANAGEMENT PERMIT APPLICATION FORM
This form may be photocopied for use as an original
I GENERAL INFORMATION
1 Applicants name (specify the name of the corporation, individual, etc who owns the project)
2 Print Owner/Signing Official's name and title (person legally responsible for facility and compliance)
'+ o
3 Mailing Address for person listed in item 2 above IIr���Di
City \A1hi'}c,V1 X19 / State N G Zip Z8q-jZ
Telephone Number ( 910 ) 91'-i- 424I
4 Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans
specifications, letters, operation and maintenance agreements, etc )
Nb 1AC44MA .0 _P AAA
5 Location of Project (street address)
211
City ISOU44nk.00( T, _.. County t=-c Jnswic F._
6 Directions to project (from nearest major intersection)
7
Latitude W3 $'�'— 1/'i Longitude :7$!- 03,- 10"I of project
8 Contact person who can answer questions about the project tp
Name Kd -��L( A,-Jd Telephone Number ( 910 ) -4t02' LIZ 00
II PERMIT INFORMATION ZNew
1 Specify whether project is (check one) Renewal Modification
Forn SWU-101 Version 3 99 Page I of
2 If this application is being subm tted as the result of a renewal or modification to an existing permit, list the
existing permit number iA- and its issue date (if known)
3 Specify the type of project (check one)
Low Density ✓ High Density Redevelop General Permit Other
4 Additional Project Requirements (check applicable blanks)
CAMA Major ✓Sedimentation/Erosion Control 404/401 Permit _NPDES Stormwater
Information on required state permits can be obtained by contacting the Customer Service Center at
1-877-623-6748
III PROJECT INFORMATION
1 In the space provided below, summarize how stormwater will be treated Also attach a detailed narrative
(one to two pages) describing stormwater management for the project
— -54m my-)&. -zr w al h_ — Go l i cc.;-�J I+6-yw �1 cv Y b i k 1a {ems ow
GGC IbSCCc79,4u,i4- SUS�G+ ►rol�z" hltne.V+ `6 tue4 k4J-70n h6sly
Stormwater runoff from this project drains to the T t -1r River basin
3 Total Project Area 1.4 acres 4
S;4e, ar4&:)
5 How many drainage areas does the project have?--[--_
Project Built Upon Area J %
on -so fe— , cry. "46
Sl fd oLrecL
6 Complete the following information for each drainage area If there are more than two drainage areas in the
project, attach an additional sheet with the information for each area provided in the same format as below
Basin Information
Drainage Area 1
Drainage Area 2
Receiving Stream Name
Cr
Receiving Stream Class
SG s W
Drainage Area
S
g` SF
Existing Impervious* Area
t. I wo -5,F so
Proposed Impervious*Area
rf 1--
% Impervious* Area (total)
.3 Z.
Impervious* Surface Area
Drainage Area 1
Drainage Area 2
On -site Buildings
G 3 3 s
On -site Streets
On -site Parking
7 0 S 2 S F
On -site Sidewalks
ISr
Other on -site
Off -site
my Sr
Total q SF
Total
* Impervious area Is defined as the built upon area including, but not limited to, buildings, roads, parking areas,
sidewalks, gravel areas, etc
Form SWU-101 Vernon 3 99 Page 2 of 4
7 How was the off -site impervious area listed above derived?_Af�e'j_ k0�� F' o s
IV DEED RESTRICTIONS AND PROTECTIVE COVENANTS
The following italicized deed restrictions and protective covenants are required to be recorded for all
subdivisions, outparcels and future development prior to the sale of any lot If lot sizes vary significantly a table
listing eoLi lot number size and the allowable built -upon area for each It it -rust be provided as an attachment
The following covenants are intended to ensure ongoing compliance with state stormwater management permit number
as issued by the Division of Water Quality These covenants may not be
changed or deleted without the consent of the State
No more than square feet of any lot shall be covered by structures or impervious materials
Impervious materials include asphalt, gravel, concrete brick stone slate or similar material but do not include wood
decking or the water surface of swimming pools
3 Swales shall not be filled in, piped, or altered except as necessary to provide driveway crossings
4 Built -upon area in excess of the permitted amount requires a state stormwater management permit modification prior to
construction
5 All permitted runoff from outparcels or future development shall be directed into the permitted stormwater control
system These connections to the stormwater control system shall be performed in a manner that maintains the integrity
and performance of the system as permitted
By your signature below, you certify that the recorded deed restrictions and protective covenants for this project
shall include all the applicable items required above, that the covenants will be binding on all parties and persons
claiming under them that they will run with the land, that the required covenants cannot be changed or deleted
without concurrence from the State and that they will be recorded prior to the sale of any lot
V SUPPLEMENT FORMS
The applicable state stormwater management permit supplement form(s) listed below must be submitted for each
BMP specified for this project Contact the Stormwater and General Permits Unit at (919) 733-5083 for the status
and availability of these forms
Form SWU-102
Wet Detention Basin Supplement
Form SWU-103
Infiltration Basin Supplement
Form SWU-104
Low Density Supplement
Form SWU-105
Curb Outlet System Supplement
Form SWU-106
Off -Site System Supplement
Form SWU-107
Underground Infiltration Trench Supplement
Form SWU-108
Neuse River Basin Supplement
Form SWU-109
Innovative Best Management Practice Supplement
Form SWU-101 Version 3 99 Page 3 of 4
VI SUBMITTAL REQUIREMENTS
Only complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ)
A complete package includes all of the items listed below The complete application package should be
submitted to the appropriate DWQ Regional Office
1 Please indicate that you have provided the following required information by initialing in the space provided
next to each item
Im als
• Original and one copy of the Stormwater Management Permit Application Form
• One copy of he applicable Supplement Form(s) for each BMP
• Permit application processing fee of$+?"payable to NCDENR) $&ta60.9'0-
• Detailed narrative description of Stormwater treatment/management Q
• Two copies of plans and specifications, including
Development/Project name
Engineer and firm
-Legend
- North arrow
- Scale
- Revision number & date
- Mean high water line
- Dimensioned property/project boundary
- Location map with named streets or NCSR numbers
- Original contours, proposed contours spot elevations finished floor elevations
- Details of roads drainage features, collection systems, and stormwater control measures
- Wetlands delineated or a note on plans that none exist
- Existing drainage (including off -site), drainage easements, pipe sizes runoff calculations
- Drainage areas delineated
- Vegetated buffers (where required)
VII AGENT AUTHORIZATION
If you wish to designate authority to another individual or firm so that they may provide information on your
behalf, please complete this section
Designated agent (individual or firm)_I p/�ja,c � 3p i.i_�►�C�+ + Ej, CEGiI'i 111�k bickSaV *Cdtf e�c
Mailing Address 90 11/3�1'IC �.T iJke-e-� w
City _ W A Mi &a6z _ State _,LUG Zip
Phone ( 910 ) -1(,e2- 4126b _ Fax (_9'Ir? ) 2(00- N201
VIII APPLICANT'S CERTIFICATION
I (print or type name of person listed In General Information item 2) �f^ACI Ord L7aulSp�v
certify that the information included on this permit application form is o the best of my knowledge correct and
that the project will be constructed in conformance with the approved plans that the required deed restrictions
and protective covenants will be recorded, and that the proposed project complies with the requirements of 15A
NCAC 2H r�
Signature
Form SWU-101 Version 3 99 Page 4 of 4
Date /0 I Z-Yle)S_,
Permit No ,'S' &:5:
(to he provided by DWQ)
State of North Carolina
Department of Environment and Natural Resources
Division of Water Quality
STORMWATER MANAGEMENT PERMIT APPLICATION FORM
WET DETENTION BASIN SUPPLEMENT
This form may be photocopied for use as an original
DWQ Stormwater Management Plan Review
A complete stormwater management plan submittal includes an application form, a wet detention basin
supplement for each basin, design calculations, and plans and specifications showing all basin and outlet
structure details
I. PROJECT INFORMATION
Project Name wgcGq MAW_ 9)iNk
Contact Person ?&crV Bred;«d 0Au1S6n, Phone Number 6110 ) °1lq- 41201
For projects with multiple basins, specify which basin this worksheet applies to 1
elevations
Basin Bottom Elevation ZB O ft (floor of the basin)
Permanent Pool Elevation 32 0 ft (elevation of the orifice)
Temporary Pool Elevation 3z , ft (elevation of the discharge structure overflow)
areas
Permanent Pool Surface Area 832 sq ft (water surface area at the orifice elevation)
Drainage Area i • z 6 ac (on -site and off -site drainage to the basin)
Impervious Area ate_ ac (on -site and off -site drainage to the basin)
volumes
Permanent Pool Volume 101 24 cu ft (combined volume of main basin and forebay)
Temporary Pool Volume J�(a.3 L' cu ft (volume detained above the permanent pool)
Forebay Volume Zt 2 (off cu ft (approximately 20% of total volume)
Other parameters
SA/DAI 82- (surface area to drainage area ratio from DWQ table)
Diameter of Orifice in (2 to S day temporary pool draw -down required)
Design Rainfall 1 in
Design TSS Removal 2 Rd % (minimum 85% required)
Fonr SWU-102 Rev 3 99 Page I of 4
Footnotes
When using the Division SA/DA tables, the correct SA/DA ratio for pennanent pool sizing should be computed based upon the
actual impervious % and permanent pool depth Linear interpolation should be employed to determine the correct value for non-
standard table entries
In the 20 coastal counties, the requirement for a vegetative filter may be waived if the wet detention basin is designed to provide
90% TSS removal The NCDENR BMP manual provides design tables for both 85% TSS removal and 90% TSS removal
IL REQUIRED ITEMS CHECKLIST
The following checklist outlines design requirements per the Stormwater Best Management Practices Manual
(N C Department of Environment, Health and Natural Resources, February 1999) and Administrative Code
Section 15 A NCAC 2H 1008
Initial in the space provided to indicate the following design requirements have been met and supporting
documentation is attached If the applicant has designated an agent in the Stormwater Management Permit
Application Form, the agent may initial below If a requirement has not been met, attach Justification.
Applicants Initials
a
b
c
d
e
T�_b
The permanent pool depth is between 3 and 6 feet (required minimum of 3 feet)
The forebay volume is approximately equal to 20% of the basin volume
The temporary pool controls runoff from the design storm event
The temporary pool draws down in 2 to 5 days
If required, a 30-foot vegetative filter is provided at the outlet (include non -erosive flow
calculations) Pik
f The basin length to width ratio is greater than 3 1
g The basin side slopes above the permanent pool are no steeper than 3 1
h A submerged and vegetated perimeter shelf with a slope of 6 1 or less (show detail)
Vegetative cover above the permanent pool elevation is specified
A trash rack or similar device is provided for both the overflow and onfice
k A recorded drainage easement is provided for each basin including access to nearest right-
of-way 4-
1 If the basin is used for sediment and erosion control during construction, clean out of the
basin is specified prior to use as a wet detention basin
in A mechanism is specified which will drain the basin for maintenance or an emergency
III. WET DETENTION BASIN OPERATION AND MAINTENANCE AGREEMENT
The wet detention basin system is defined as the wet detention basin, pretreatment including forebays and the
vegetated filter if one is provided
This system (check one) 0 does�es not incorporate a vegetated filter at the outlet.
f
This system (check one) 0 does :'does not incorporate pretreatment other than a forebay.
Form SWU-102 Rev 3 99 Page 2 of 4
Maintenance activities shall be performed as follows
After every significant runoff producing rainfall event and at least monthly
a Inspect the wet detention basin system for sediment accumulation, erosion, trash accumulation,
vegetated cover, and general condition
b Check and clear the onfice of any obstructions such that drawdown of the temporary pool occurs within
2 to 5 days as designed
2 Repair eroded areas immediately, re -seed as necessary to maintain good vegetative cover, mow vegetative
cover to maintain a maximum height of six inches, and remove trash as needed
3 Inspect and repair the collection system (i a catch basins, piping, swales, nprap, etc ) quarterly to maintain
proper functioning
4 Remove accumulated sediment from the wet detention basin system semi-annually or when depth is
reduced to 75% of the original design depth (see diagram below) Removed sediment shall be disposed of
in an appropriate manner and shall be handled in a manner that will not adversely impact water quality (i e
stockpiling near a wet detention basin or stream, etc )
The measuring device used to determine the sediment elevation shall be such that it will give an accurate
depth reading and not readily penetrate into accumulated sediments
When the permanent pool depth reads 3 O feet in the main pond, the sediment shall be removed
When the permanent pool depth reads -3 0_ feet in the forebay, the sediment shall be removed
BASIN DIAGRAM
(fill in the hlanks)
0 Permanent Pool Elevation 32
Sediment R\Ele
al El .O 75 0
-------------- - Sediment Removal Elevation 29• d 75%
Bottomahon Z� %---------------------------------- ---------- ------
Bottom Elevation �8 D 25%
FOREBAY MAIN POND
5 Remove cattails and other indigenous wetland plants when they cover 50% of the basin surface These
plants shall be encouraged to grow along the vegetated shelf and forebay berm
6 If the basin must be drained for an emergency or to perform maintenance, the flushing of sediment through
the emergency drain shall be minimized to the maximum extent practical
Form SWU-102 Rev 3 99 Page 3 of 4
7 All components of the wet detention basin system shall be maintained in good working order
I acknowledge and agree by my signature below that I am responsible for the performance of the seven
maintenance procedures listed above I agree to notify DWQ of any problems with the system or prior to any
changes to the system or responsible party
Print name rnd i-orclD
"Iitle Senunr t?msidenT
Address 110 Al. MK. 1�- weLZ 'BIod W odle fi Nc zwilZ
Phon
Signs
Date
Note The legally responsible party should not be a homeowners association unless more than 50% of the lots have been sold and a
resident of the subdivision has been named the president
I, J - EfDw4-+ , a Notary Public for the State of
County of Y � AA"PyyLr , do hereby certify that H_ "8rcr�_t�e� "�a•ws tnr�
personally appeared before me this `->L&�'-day of C.�vbt2 ,20i��, and acknowledge the due
execution of the forgoing wet detention basin maintenance requirements Witness my hand and official seal,
S e
IOTA Rk
* CIBL\G
SEAL
My commission expires �M �+�► a, Zd D
Form SWU- l02 Rev 3 99 Page 4 of 4
State Stormwater Management Systems
Permit No SW8 051117
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
DIVISION OF WATER QUALITY
STATE STORMWATER MANAGEMENT PERMIT
HIGH DENSITY DEVELOPMENT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of
North Carolina as amended, and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Perry Bradford Dawson and Waccamaw Bank
Waccamaw Bank, 4945 Southport -Supply Road, Southport
Brunswick County
FOR THE
construction, operation and maintenance of a wet detention pond in compliance with
the provisions of 15A NCAC 2H 1000 (hereafter referred to as the "stormwater rules')
and the approved stormwater management plans and specifications and other
supporting data as attached and on file with and approved by the Division of Water
Quality and considered a part of this permit
This permit shall be effective from the date of issuance until December 19, 2015, and
shall be subject to the following specified conditions and limitations
I DESIGN STANDARDS
This permit is effective only with respect to the nature and volume of stormwater
described in the application and other supporting data
2 This stormwater system has been approved for the management of stormwater
runoff as described in Section 16 on page 3 of this permit The stormwater
control has been designed to handle the runoff from 42,974 square feet of
impervious area
3 The tract will be limited to the amount of built -upon area indicated on page 3 of
this permit, and per approved plans There is no allotment for future built -upon
area at the site
4 All stormwater collection and treatment systems must be located in either
dedicated common areas or recorded easements The final plats for the project
will be recorded showing all such required easements, in accordance with the
approved plans
5 The runoff from all built -upon area within the permitted drainage area of this
project must be directed into the permitted stormwater control system
Page 2 of 7
State Stormwater Management Systems
Permit No SW8 051117
6 The following design criteria have been provided in the wet detention pond and
must be maintained at design condition
a Drainage Area, acres
Onsite, ft
Offsite, ft2
b Total Impervious Surface, ft2
Onsite Buildings, It
Onsite Parking, ft 2
Onsite SYewalks, ft
Offsite, ft
c Design Storm, inches
d Pond Depth, feet
e TSS removal efficiency
f Permanent Pool Elevation, FMSL
g Permanent Pool Surface Area, ft2
h Permitted Storage Volume, ft3
Temporary Storage Elevation, FMSL
I Controlling Orifice
k Permitted Forebay Volume, ft3
1 Receiving Stream/River Basin
m Stream Index Number
n Classification of Water Body
11. SCHEDULE OF COMPLIANCE
42,974
6,331
27,052
1,591
8,000
10
40
90%
320
4,832
3,634
3288
0 75" 0 pipe
2,265
Jump and Run Creek I Cape Fear
18-88-9-3-2
"SC, Sw"
1 The stormwater management system shall be constructed in its entirety,
vegetated and operational for its intended use prior to the construction of any
built -upon surface
2 During construction, erosion shall be kept to a minimum and any eroded areas of
the system will be repaired immediately
3 The permittee shall at all times provide the operation and maintenance
necessary to assure the permitted stormwater system functions at optimum
efficiency The approved Operation and Maintenance Plan must be followed in
its entirety and maintenance must occur at the scheduled intervals including, but
not limited to
a Semiannual scheduled inspections (every 6 months)
b Sediment removal
c Mowing and revegetation of slopes and the vegetated filter
d Immediate repair of eroded areas
e Maintenance of all slopes in accordance with approved plans and
specifications
f Debris removal and unclogging of outlet structure, orifice device, flow
spreader, catch basins and piping
g Access to the outlet structure must be available at all times
Page 3 of 7
State Stormwater Management Systems
Permit No SW8 051117
4 Records of maintenance activities must be kept and made available upon
request to authorized personnel of DWQ The records will indicate the date,
activity, name of person performing the work and what actions were taken
5 Decorative spray fountains will be allowed in the stormwater treatment system,
subject to the following criteria
a The fountain must draw its water from less than 2' below the permanent
pool surface
b Separated units, where the nozzle, pump and intake are connected by
tubing, may be used only if they draw water from the surface in the
deepest part of the pond
c The falling water from the fountain must be centered in the pond, away
from the shoreline
d The maximum horsepower for a fountain in this pond is 118 horsepower
6 The facilities shall be constructed as shown on the approved plans This permit
shall become voidable unless the facilities are constructed in accordance with
the conditions of this permit, the approved plans and specifications, and other
supporting data
7 Upon completion of construction, prior to issuance of a Certificate of Occupancy,
and prior to operation of this permitted facility, a certification must be received
from an appropriate designer for the system installed certifying that the permitted
facility has been installed in accordance with this permit, the approved plans and
specifications, and other supporting documentation Any deviations from the
approved plans and specifications must be noted on the Certification A
modification may be required for those deviations
8 If the stormwater system was used as an Erosion Control device, it must be
restored to design condition prior to operation as a stormwater treatment device,
and prior to occupancy of the facility
9 Access to the stormwater facilities shall be maintained via appropriate
easements at all times
10 The permittee shall submit to the Director and shall have received approval for
revised plans, specifications, and calculations prior to construction, for any
modification to the approved plans, including, but not limited to, those listed
below
a Any revision to any item shown on the approved plans, including the
stormwater management measures, built -upon area, details, etc
b Project name change
c Transfer of ownership
d Redesign or addition to the approved amount of built -upon area or to the
drainage area
e Further subdivision, acquisition, lease or sale of all or part of the project
area The project area is defined as all property owned by the permittee,
for which Sedimentation and Erosion Control Plan approval or a CAMA
Major permit was sought
f Filling in, altering, or piping of any vegetative conveyance shown on the
approved plan
11 The permittee shall submit final site layout and grading plans for any permitted
future areas shown on the approved plans, prior to construction
12 A copy of the approved plans and specifications shall be maintained on file by
the Permittee for a minimum of ten years from the date of the completion of
construction
Page 4 of 7
State Stormwater Management Systems
Permit No SW8 051117
13 The Director may notify the permittee when the permitted site does not meet one
or more of the minimum requirements of the permit Within the time frame
specified in the notice, the permittee shall submit a written time schedule to the
Director for modifying the site to meet minimum requirements The permittee
shall provide copies of revised plans and certification in writing to the Director
that the changes have been made
III GENERAL CONDITIONS
This permit is not transferable except after notice to and approval by the Director
In the event of a change of ownership, or a name change, the permittee must
submit a formal permit transfer request to the Division of Water Quality,
accompanied by a completed name/ownership change form, documentation
from the parties involved, and other supporting materials as may be appropriate
The approval of this request will be considered on its merits and may or may not
be approved The permittee is responsible for compliance with all permit
conditions until such time as the Division approves the transfer request
2 Failure to abide by the conditions and limitations contained in this permit may
subject the Permittee to enforcement action by the Division of Water Quality, in
accordance with North Carolina General Statute 143-215 6A to 143-215 6C
3 The issuance of this permit does not preclude the Permittee from complying with
any and all statutes, rules, regulations, or ordinances, which may be imposed by
other government agencies (local, state, and federal) having jurisdiction
4 In the event that the facilities fail to perform satisfactorily, including the creation
of nuisance conditions, the Permittee shall take immediate corrective action,
including those as may be required by this Division, such as the construction of
additional or replacement stormwater management systems
5 The permittee grants DENR Staff permission to enter the property during normal
business hours for the purpose of inspecting all components of the permitted
stormwater management facility
6 The permit may be modified, revoked and reissued or terminated for cause The
filing of a request for a permit modification, revocation and reissuance or
termination does not stay any permit condition
7 Unless specified elsewhere, permanent seeding requirements for the stormwater
control must follow the guidelines established in the North Carolina Erosion and
Sediment Control Planning and Design Manual
8 Approved plans and specifications for this project are incorporated by reference
and are enforceable parts of the permit
9 The permittee shall notify the Division any name, ownership or mailing address
changes within 30 days
Permit issued this the 19th day of December 2005
NORTH OLINA ENVIRONMENTAL MANAGEMENT COMMISSION
for a W Klimek, E , Director
Division of Water Quality
By Authority of the Environmental Management Commission
Page 5 of 7
State Stormwater Management Systems
Permit No SW8 051117
Waccamaw Bank
Stormwater Permit No SW8 051117 Page 1 of 2
Brunswick Count
Designer's Certification
1, , as a duly registered
in the State of North Carolina, having been authorized to observe (periodically/ weekly/
full time) the construction of the project,
(Project)
for (Project Owner) hereby state that, to the
best of my abilities, due care and diligence was used in the observation of the protect
construction such that the construction was observed to be built within substantial
compliance and intent of the approved plans and specifications
The checklist of items on page 2 of this form is included in the Certification
Noted deviations from approved plans and specification
Signature
Registration Number
Date
SEAL
Page 6 of 7
State Stormwater Management Systems
Permit No SW8 051117
Page 2 of 2
Certification Requirements
1 The drainage area to the system contains approximately the permitted
acreage
2 The drainage area to the system contains no more than the permitted
amount of built -upon area
3 All the built -upon area associated with the project is graded such that the
runoff drains to the system
4 All roof drains are located such that the runoff is directed into the system
5 The outlet/bypass structure elevations are per the approved plan
6 The outlet structure is located per the approved plans
7 Trash rack is provided on the outlet/bypass structure
8 All slopes are grassed with permanent vegetation
9 Vegetated slopes are no steeper than 3 1
10 The inlets are located per the approved plans and do not cause short-
circuiting of the system
11 The permitted amounts of surface area and/or volume have been
provided
12 Required drawdown devices are correctly sized per the approved plans
13 All required design depths are provided
14 All required parts of the system are provided, such as a vegetated shelf,
and a forebay
15 The required system dimensions are provided per the approved plans
cc NCDENR-DWQ Regional Office
Delaney Aycock, Brunswick County Building Inspections
Jeff Phillips, Brunswick County Engineering
Page 7of7