Loading...
HomeMy WebLinkAboutWI0400551_More Information (Received)_20200917DUKE 526 South Church St Mail Code EC13K �. ENERGY® Charlotte, NC 28202 CAROLINAS September 17, 2020 Mr. Michael Rogers N.C. Department of Environmental Quality Division of Water Resources, UIC Program 1636 Mail Service Center Raleigh, North Carolina 27699-1636 Subject: Underground Injection Permit Application Duke Energy Carolinas, LLC Belews Creek Steam Station 3195 Pine Hall Road, Belews Creek, NC 27009 Mr. Michael Rogers, On behalf of Duke Energy Carolinas, LLC (Duke Energy), AECOM Technical Services of North Carolina Inc. (AECOM) completed infiltration source water sampling at Belews Lake for perfluoro-1-butanesulfonic acid (PFBS), perfluoro-n-octanoic acid (PFOA), and perfluorooctanesulfonic acid (PFOS) on September 2, 2020. This sampling was completed as requested in the August21, 2020 email from you requesting that PFOS/PFOA data be submitted to the UIC Program and the Winston-Salem Regional Office for review. A summary of the results is included below and the analytical report from Pace Analytical Services, LLC a North Carolina Certified Laboratory is provided as Attachment A. PFBS, PFOA, and PFOS were not detected above the EPA Screening Level, the USEPA lifetime drinking water health advisory levels, or the 15A NCAC 2L Interim Maximum Allowable Concentration. Notes: 1 - EPA Screening Level Summary Table, November 2019 2 - EPA, PFOA and PFOS Drinking Water Health Advisories Fact Sheet, May 2016 IMAC - 15A NCAC 2L Interim Maximum Allowable Concentration PFBS - Perfluoro-1-butanesulfonic acid PFOA - Perfluoro-n-octanoic acid PFOS - Perfluorooctanesulfonic acid NS - No Standard All units are reported in nanograms per liter (ng/L) Bold - compound detected BUILDING A SMARTER ENERGY FUTURE'" September 15, 2020 Page 2 Please contact Mr. Andrew Shull (919.546.2104) or Mr. Scott Davies (980.373.6563) with any questions or concerns. Sincerely, Andrew W. Shull, P.E. Duke Energy EHS cc: Rick Bolich, NCDEQ Steve Lanter, NCDEQ Eric Smith, NCDEQ Ed Sullivan, Duke Energy John Toepfer, Duke Energy Scott Davies, Duke Energy Melonie Martin, Duke Energy Matthew Allen, AECOM Bob Wyrick, AECOM Attachments Attachment A — Laboratory Analytical Report September 15, 2020 Page 3 ATTACHMENT A Laboratory Analytical Report 0p 0 PaceAnalyfical Report of Analysis Pace Analytical Services, LLC 9800 Kincey Avenue Suite 100 Huntersville, NC 28078 Attention: Kevin Herring Project Name: PFAS Project Number: 92493663 Lot Number:V103070 Date Completed:09/15/2020 Revision Date: 09/14/2020 09/15/2020 10:06 AM Approved and released by: Project Manager II: Cathy S. Dover Q PCCR�c��� AAW 'ye I ANSI NdmlAccre00- Board eORft Al A C C R E D I T E D TESTING LABORATORY The electronic signature above is the equivalent of a handwritten signature. This report shall not be reproduced, except in its entirety, without the written approval of Pace Analytical Services, LLC. Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 Tel:803-791-9700 Fax:803-791-9111 www.pacelabs.com Page 1 of 12 PACE ANALYTICAL SERVICES, LLC SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 Case Narrative Pace Analytical Services, LLC Lot Number: V103070 This Report of Analysis contains the analytical result(s) for the sample(s) listed on the Sample Summary following this Case Narrative. The sample receiving date is documented in the header information associated with each sample. All results listed in this report relate only to the samples that are contained within this report. Sample receipt, sample analysis, and data review have been performed in accordance with the most current approved NELAC standards, the Pace Analytical Services, LLC ('Pace") Quality Assurance Management Plan (QAMP), standard operating procedures (SOPs), and Pace policies. Any exceptions to the NELAC standards, the QAMP, SOPs or policies are qualified on the results page or discussed below. This PDF report has been revised to report only PFOA, PFOA and PFBS per client request. PFAS 537 ID Samples V103070-001 (SW-09022020) and V103070-002 (TRIP BLANK) were collected in client provided HDPE bottles. While this is method compliant, the sample bottles were not provided by the laboratory. If you have any questions regarding this report please contact the Pace Project Manager listed on the cover page. Pace Analytical Services, LLC (formerly Shealy Environmetal Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 vvww.pacelabs.com Page 2 of 12 PACE ANALYTICAL SERVICES, LLC Sample Summary Pace Analytical Services, LLC Lot Number: V103070 Project Name: PFAS Project Number: 92493663 Sample Number Sample ID Matrix Date Sampled Date Received 001 SW-09022020 Aqueous 09/02/20201240 09/03/2020 002 TRIP BLANK Aqueous 09/02/2020 09/03/2020 (2 samples) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 3of12 PACE ANALYTICAL SERVICES, LLC Detection Summary Pace Analytical Services, LLC Lot Number: V103070 Project Name: PFAS Project Number: 92493663 Sample Sample ID Matrix Parameter Method Result Q Units Page 001 SW-09022020 Aqueous PFOS PFAS by ID 3.8 ng/L 5 (1 detection) Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 4of12 PFAS by LC/MS/MS Client: Pace Analytical Services, LLC Laboratory ID:VI03070-001 Description: SW-09022020 Matrix: Aqueous Date Sampled:09/02/2020 1240 Project Name: PFAS Date Received:09/03/2020 Project Number: 92493663 Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 SOP SPE PFAS by ID SOP 1 09/10/2020 1224 MMM 09/08/2020 1011 65915 CAS Analytical Parameter Number Method Result Q LOQ Units Run Perfluoro-1-butanesulfonic acid (PFBS) 375-73-5 PFAS by ID SOP ND 3.4 ng/L 1 Perfluoro-n-octanoic acid (PFOA) 335-67-1 PFAS by ID SOP ND 3.4 ng/L 1 Perfluorooctanesulfonic acid (PFOS) 1763-23-1 PFAS by ID SOP 3.8 3.4 ng/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 13C3 PFBS 100 25-150 13C8 PFOA 116 25-150 13C8 PFOS 101 25-150 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range ND = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % H = Out of holding time W = Reported on wet weight basis Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 5of12 PFAS by LC/MS/MS Client: Pace Analytical Services, LLC Laboratory ID:VI03070-002 Description: TRIP BLANK Matrix: Aqueous Date Sampled:09/02/2020 Project Name: PFAS Date Received:09/03/2020 Project Number: 92493663 Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 SOP SPE PFAS by ID SOP 1 09/09/2020 1849 MMM 09/08/2020 1011 65915 CAS Analytical Parameter Number Method Result Q LOQ Units Run Perfluoro-1-butanesulfonic acid (PFBS) 375-73-5 PFAS by ID SOP ND 3.4 ng/L 1 Perfluoro-n-octanoic acid (PFOA) 335-67-1 PFAS by ID SOP ND 3.4 ng/L 1 Perfluorooctanesulfonic acid (PFOS) 1763-23-1 PFAS by ID SOP ND 3.4 ng/L 1 Run 1 Acceptance Surrogate Q % Recovery Limits 13C3 PFBS ill 25-150 13C8 PFOA 113 25-150 13C8 PFOS 113 25-150 LOQ = Limit of Quantitation B = Detected in the method blank E = Quantitation of compound exceeded the calibration range ND = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % H = Out of holding time W = Reported on wet weight basis Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 6of12 QC Summary Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: V103070 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 7 of 12 PFAS by LC/MS/MS - MB Sample ID: VQ65915-001 Matrix: Aqueous Batch:65915 Prep Method: SOP SPE Analytical Method: PFAS by ID SOP Prep Date: 09/08/2020 1011 Parameter Result Q Dil LOQ Units Analysis Date PFBS ND 1 4.0 ng/L 09/09/2020 1420 PFOA ND 1 4.0 ng/L 09/09/2020 1420 PFOS ND 1 4.0 ng/L 09/09/2020 1420 Acceptance Surrogate Q % Rec Limit 13C3 PFBS 95 25-150 13C8 PFOA 105 25-150 13C8 PFOS 102 25-150 LOQ = Limit of Quantitation ND = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: V103070 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 8of12 PFAS by LC/MS/MS - LCS Sample ID: VQ65915-002 Matrix: Aqueous Batch:65915 Prep Method: SOP SPE Analytical Method: PFAS by ID SOP Prep Date: 09/08/2020 1011 Spike Amount Result % Rec Parameter (ng/L) (ng/L) Q Dil % Rec Limit Analysis Date PFBS 14 14 1 100 50-150 09/09/20201431 PFOA 16 16 1 99 50-150 09/09/20201431 PFOS 15 14 1 97 50-150 09/09/20201431 Acceptance Surrogate Q % Rec Limit 13C3 PFBS 98 25-150 13C8 PFOA 97 25-150 13C8 PFOS 97 25-150 LOQ = Limit of Quantitation ND = Not detected at or above the LOQ N = Recovery is out of criteria P = The RPD between two GC columns exceeds 40 % + = RPD is out of criteria Note: Calculations are performed before rounding to avoid round -off errors in calculated results Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) QC Data for Lot Number: V103070 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 9of12 Chain of Custody and Miscellaneous Documents Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 10 of 12 PACE ANALYTICAL SERVICES, LLC D C3 r M f ZZ w Cn Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 11 of 12 PACE ANALYTICAL SERVICES, LLC ShunlY l-nvinmm.wlul fl7u M, LIC. P.y;a L ,11'1 rS.J.LW.ML^ Y. rereUlat-]A lhwe MOM Sample Receipt Checklist (SRQ Cliur-u P&M Coole. Inspected be doe! L'�" ; 09.+3r'20211) Lot #; V103070 Means ofreceipi; SESr ❑ C1:en, E. UPI, „a Felix Dthor ❑ Yesl ® N o ! , V4'ere custody Deal:. present on thz coala? c-3 El 1,ru 1 0 7 -At 2. If Gusto* aGR15 W*T sent, Were ji ' 61tact Snc unbwkvn? H S'trip 11i= NA Chlorine Strip l t3: N A Tested by: NA - - _ igillal tem�enrature upon raceirt / Dcrived(Corrected) tempe*ature u-�un receipt °/Solid Snap -Cup ID: NA J.0 13.0 OVA INA _aC NA JKA rC NA ,INA ¢C Mc l&A_ ©Tgmpt;rature [3lank mAgaillst ]3ottk;s Ili Gun ID- 5 R Cvn Cnrrecl.ion 13Ct0r: 'G CNet[eod of coolaritr 91 Alct [cc ❑ 11u Pac:,s R Drs' 1c{; ❑ Noll' ❑ Yca ❑ Na VINA 3. 1f r. riiurr nFany "ler exceeded6.(F ;, was I'Tojoct tw1a3agcT1l0tiFhkl? PM wa-5 NDti=iec b,= pkone 1 email; facto -face (circle one). ® Yes ❑ No ❑ NA -1. Is t6a comrce rc.ial cnuritw: E par.;king slip ;Llached *o this 1;w1A Yes ❑ No S- Were ro ei- canLody procedures (felinrluisl�cclLzc�iv�d) fnl I &%'d ? ® Yes 0 No 6. '44'= sample [Ds IisW,,mi '1Le COC? 17. Wero sample TDs 3imd w all na Le conzainem? Yes ❑ No lF Yes ❑ N43 S- 'Vas collecli m date a line listed an the COC? ® Yes ❑ No 9- %Vnt collection date a time listed an all sample coda hwrs? J Yes ❑ No 10. Did all container label inthrmatinn (I D- data, time) agrep ivefi thy. UUC e ® yes ❑ -No I I- Wcro WA4 N L hL pur-F orrFLud lipird On L11t: COC'1 12. Did 21l sanlpl es arrive in the proper omitahers for cacti lest and/or in guod COJI i l iun (imbroken, Lids on, etc j'i' Yes El ]`IL] ® Ye; ❑ No 1-�. Was adequate sample volume a%railabl='i Yes ❑ No 14, R'rrn u[i surrjpies i-oceived WA[1LL1 4A the holding 1jine or 48 11aLIT5, wbic.lirv-r r.:xne�, lust? 15. Were any samples oantamers missing/.-xcum (cirvle cnc) 5wrnple8 -KEr L lister On c0c t Yes No © Ycs ❑ 'es ❑ Nc, [� lye ® NA 16. FairVOA wLd RSK-175 s mplM were bubbles present>"pea-size'° (1ra':-or�T in dizmetor) in my rif lh�! VOA vi-uls? _ �O NA 17. Were all Marrke'alsrnutriert sairples reoei i+ed at a pH of < 27 ❑ Yes Lj No NA IS. V+Wcrc all cyanift Sam leg received at a pII .r 12. and qu [f..de .samples received at a pH > 9`e El Yes El O NA 19' Were all applicable t4H,riK cyanide, heL.al�5�5 �{ ,Smg ') yarn les free prmWupl cF.lorine7 L11:1j:yz.' ❑No ONA - ue-climt m-jnurWr;:qu sts{1.4, ray ursttfd Oilulioii$, MS,%19D des'Vat:on&, etc-Uvm lly transaibud [rain t[m COC irtto f13G curik.-ki Jlt sedian iri LIMS? 2Was dN quoto number listed or the ean[niecr _€LUel? if , QLLCFLe f` NA Sample Prxaervalion l;[1 aa1b uulLLp]Lca1 rL,r�„y saLt;ple(s} illcon�eLat[y preserved or Witt rcadspaoc.) 5.atnpiefs) NA wttrv. nxx:ivot3 inamrr=d:t VreL-&vvrx[ arid were 4u'A amlu&k)i :y ir, shirr le;eceivi" With NA nil- of circle one, W?804, HNO3, HC1, NgnB ij- >jn SR 4 Nf� Tune ocpn)sk�i%vion NA If mo-e than Due praserva ivo is nuedW. I [cmc note in the corlrnenls below. Sauiple(s) NA - were receivad with hubbler.76mm ui d:amcmm Snrnlrles(.5) N. were rccohcd w!Ek TRC �- 0.5 TwL (If 419 is xo ) and %sere sdjtlsrted u4mclirlaly in sample. receiving w;6 sodium tHasulfaoe (NaIS24) vdth Shay ID: NA _ .. SR htarcode lob:d gp:ldd W: B MG Date: ORM2020LL— Comrorn-m Pace Analytical Services, LLC (formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.pacelabs.com Page 12 of 12