August 25, 2020
CERTIFIED MAIL #: 70191120 0000 8361 0407
RETURN RECEIPT REQUESTED
Mr. Tony Konsul
Carolina Water Service, Inc. of NC
Post Office Box 240908
Charlotte, North Carolina 28224
Subject: Notice of Violation
Compliance Evaluation Inspection
The Point Well 1 WTP
NPDES Permit No. NCO086592
Iredell County
Tracking #: NOV-2020-PC-0382
Dear Mr. Konsul:
Enclosed is a copy of the Compliance Evaluation Inspection Report for the inspection conducted at the subject
facility on August 11, 2020, by Mr. Wes Bell of this Office. Please inform the facility's Operator -in -Responsible
Charge (ORC) of our findings by forwarding a copy of the enclosed report.
This report is being issued as a Notice of Violation (NOV) due to failures to calibrate the flow meter annually
(2018 and 2019), which are violations of the subject NPDES Permit and North Carolina General Statute (G.S.) 143-
215.1 as detailed in the Flow Measurement/Effluent Section of the attached report. Please be advised that G.S.
143-215.6A provides for a civil penalty assessment of not more than twenty-five thousand dollars ($25,000.00), or
twenty-five thousand dollars ($25,000.00) per day when the violation is of a continuing nature, against any person
who violates or fails to act in accordance with the terms, conditions, or requirements of any permit issued pursuant
to G.S. 143-215.1. Penalties may also be assessed for any damage to surface waters of the State that may result
from the violation.
It is requested that a written response be submitted to this Office by September 15, 2020, detailing the actions
taken to address these violations. In responding, please address your comments to the attention of Mr. Wes Bell.
�� Office
Carolina Department of Environmental Quality I Division of Water Resources
Mooresville Regional 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115
NOR7H ORROLINA i
�,"rJ J m Em^'m'"^e^ai Qmli /`� 704.663.1699
Tony Konsul
Page Two
August 25, 2020
Should you have any questions concerning this letter, please do not hesitate to contact Mr. Bell at (704) 235-
2192, or via email at wes.bell(a-),ncdenr.gov.
Sincerely,
DocuSigned by:
A14CC681 AF27425...
W. Corey Basinger, Regional Supervisor
Water Quality Regional Operations Section
Division of Water Resources, NCDEQ
Enclosure:
Inspection Report
United States Environmental Protection Agency
Form Approved.
EPA Washington, D.C. 20460
OMB No. 2040-0057
Water Compliance Inspection Report
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type
1 IN 1 2 u 3 I NCO086592 I11 121 20/08/11 I17 18I � I 19 I s I 201 I
211IIIII 111111III II III III1 I I IIIII IIIIIIIII II r6
Inspection
Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved -------------------
67
2.0 70LJ 71 I„ I 72 L71 74 79
I I I I
80
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES Dermit Number)
09:30AM 20/08/11
18/12/01
The Point / Well 1 WTP
NCSR 1100
Exit Time/Date
Permit Expiration Date
Mooresville NC 28115
11:27AM 20/08/11
23/03/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Other Facility Data
Charles Edward Wood///
Cory Austin Fred el1/0RC/704-922-4086/
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Tony Konsul,PO Box 240908 Charlotte NC 282240908/Director of
Operations/704-525-7990/7045258174 No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit 0 Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran 0 Sludge Handling Dispo: Facility Site Review Effluent/Receiving Wate
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Wes Bell DocuSigned by: DWR/MRO WQ/704-663-1699 Ext.2192/ 8/24/2020
A61696D90CC3437...
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
W. Corey Basinger DWR/Division of Water Quality/704-235-2194/
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
DocuSigned by:
• 8/25/2020
AlaccsalAFvazs... Page#
NPDES yr/mo/day Inspection Type
NCO086592 I11 12I 20/08/11 117 18 i c i
(Cont.)
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
RECORD KEEPING SECTION cont'd:
On several occasions from October 2019 through February 2020, effluent values (lead, turbidity, TSS,
copper, iron and ammonia) were not reported down to the analytical method's detection/reporting limit
(a "0" was reported). Please be advised that the subject permit requires that all data generated must
be reported down to the minimum detection or lower reporting level of the test procedure [Permit
Condition Reference: Part II Section D (4) Test Procedures].
The effluent flows reported in October 2019 appeared high and should be reviewed and revised if the
flows were not transcribed properly. In addition, the September 2019 eDMR should be revised to
include the ORC and/or Backup ORC visitation not originally reported on 9/30/19.
All eDMRs must be reviewed to ensure all units of measurement (UoM) are consistent with the UoMs
listed in the permit (ex. all metals and salinity effluent results).
Page#
Permit: NCO086592 Owner - Facility: The Point / Well 1 WTP
Inspection Date: 08/11/2020 Inspection Type: Compliance Evaluation
Permit
Yes
No
NA
NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new
❑
❑
0
❑
application?
Is the facility as described in the permit?
0
❑
❑
❑
# Are there any special conditions for the permit?
0
❑
❑
❑
Is access to the plant site restricted to the general public?
0
❑
❑
❑
Is the inspector granted access to all areas for inspection?
M
❑
❑
❑
Comment: Sodium metabisulfite is not used at this facility.
The last compliance evaluation inspection at this facility was performed by
DWR staff on
ci110i11 o
Record Keeping
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operatc
on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility classification
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Yes No NA NE
•
❑
❑
❑
•
❑
❑
❑
❑
❑
❑
■
•
❑
❑
❑
•
❑
❑
❑
■
❑
❑
❑
❑
❑
■
❑
❑
❑
■
❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ■ ❑
Page# 3
Permit: NCO086592 Owner - Facility: The Point / Well 1 WTP
Inspection Date: 08/11/2020 Inspection Type: Compliance Evaluation
Record Keeping
Yes
No
NA
NE
Comment: The records reviewed during the inspection were organized and well maintained.
Discharge
Monitoring Reports (eDMRs) were reviewed for the period July 2019 through June 2020. Nc
effluent limit violations were reported all monitoring frequencies were correct.
Effluent
chronic toxicity failures were reported in September 2019, December 2019 and March 2020;
however, chronic toxicity is a monitoring only requirement.
The chain of custody forms should be updated to show sample type and preservative
(if
applicable) for each parameter sampled and the time when samples were
placed on ice.
See "Summary" Section for additional comments.
Laboratory
Yes
No
NA
NE
Are field parameters performed by certified personnel or laboratory?
0
❑
❑
❑
Are all other parameters(excluding field parameters) performed by a certified lab?
0
❑
❑
❑
# Is the facility using a contract lab?
0
❑
❑
❑
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
❑
❑
0
❑
Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
❑
❑
0
❑
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
❑
❑
0
❑
Comment: On -site field analyses (dissolved oxygen, pH, temperature, total residual chlorine) are
performed under Carolina Water Service's field laboratory certification #5228. Waypoint
Analytical (all effluent parameters except field and toxicity), Environment 1 (salinity) and ETT
Environmental (toxicity) have also been contracted to provide analytical support.
Effluent Sampling
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
representative)?
Comment: The subject permit requires effluent grab samples.
Upstream / Downstream Sampling
Is the facility sampling performed as required by the permit (frequency, sampling type, an(
sampling location)?
Yes No NA NE
❑ ❑ ■ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ■ ❑
❑ ❑ ■ ❑
■ ❑ ❑ ❑
Yes No NA NE
❑ ❑ ■ ❑
Comment: The subject permit requires downstream monitoring; however, there has been no monitoring
throughout the review period due to no instream (upstream) flows.
Page# 4
Permit: NCO086592
Inspection Date: 08/11/2020
Owner - Facility: The Point / Well 1 WTP
Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment: The filter backwash is conveyed through two settling tanks (operated in series) prior to
discharge. The solids level measured in both tanks was approximately ten inches. The
ORC and staff indicated that L&L Environmental would be contracted to remove the tank
--17,4-
The NPDES facilities appeared to be properly operated and well maintained.
De -chlorination
Type of system ?
Is the feed ratio proportional to chlorine amount (1 to 1)?
Is storage appropriate for cylinders?
# Is de -chlorination substance stored away from chlorine containers?
Are the tablets the proper size and type?
Yes No NA NE
Liquid
■ ❑
❑
❑
❑ ❑
■
❑
❑ ❑
■
❑
❑ ❑
■
❑
Comment: Sodium bisulfite is used for dechlorination and only activated during each discharge event.
Are tablet de -chlorinators operational?
Number of tubes in use?
Comment:
Flow Measurement - Effluent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
❑ ❑ ■ ❑
Yes No NA NE
■ ❑ ❑ ❑
❑ ■ ❑ ❑
■ ❑ ❑ ❑
❑ ❑ ■ ❑
Comment: The flow meter was last calibrated in 2017 by GODher Utilities: however. no flow meter
calibrations were performed in 2018 and 2019. Please be advised that the subject permit
requires flow measurement devices to be accurately calibrated at a minimum of once per
year and maintained to ensure that the accuracy of the measurements is consistent with the
accepted capability of that type of device (Permit Condition Reference: Part 11, Section D.3
Flow Measurements).
Effluent Pipe
Yes
No
NA
NE
Is right of way to the outfall properly maintained?
0
❑
❑
❑
Are the receiving water free of foam other than trace amounts and other debris?
❑
❑
❑
If effluent (diffuser pipes are required) are they operating properly?
❑
❑
0
❑
Page# 5
Permit: NC0086592
Inspection Date: 08/11/2020
Effluent Pipe
Owner - Facility: The Point / Well 1 WTP
Inspection Type: Compliance Evaluation
Comment: The facility was not discharging at the time of the inspection.
Yes No NA NE
Page#