Loading...
HomeMy WebLinkAboutWQ0012511_Sewer Extension_19960610f-2o 1 ' MEMO TO: State Review Group Division of Environmental Management FROM: Ricky Revels A.,"Jr Re-_� Fayetteville Regional Environmental Technician Office SUBJECT: Procedure Four (4) 6125196 WQ0012511 (Relocation) Date U.S. 220/SR 1530 Design #U-3310 Sewer Relocation - Public Town of E l l erbe Richmond County State Review Group Review Engineer Andy Oakley Regional Office Contact Ricky Revels 1) Name of wastewater treatment plant to receive the wastewater: Town of Ellerbe Wastewater Treatment Plant 2) WWTP design capacity 0.180 MGD 3) NPDES Permit No.: NC0021784 Expiration Date: 02 28 98 4) Compliance Information: Present treatment plant performance for previous 12 months - beginning 5195 (See attached self -monitoring data) 5) Quantity and type of wastewater from proposed sewers: 0 GPD domestic ; industrial 100% ; other 6) Volume from previously approved projects not yet tributary to WWTP 0 GPD 7) Regional Recommendations: Approval X Denial RR/rr Enclosure State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Managemen ppr!l James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary JUN 18 Ail H N A. Preston Howard, Jr., P.E., Director ENV. M, , RA `rr-* 17NT FAY.ETIEv;! .r ;.F.1;cE MAYOR JOE COMER TOWN OF ELLERBE PO BOX 3i0 F,T T,F.RRF N(-1RTH f AROT TNA ?R??R Dear MAYOR COMER: June 10, 1996 RECEWED �1.G ve►'`. of EHNR JUN 13 19% V1linsto aOffice pegio�l Suole(;t: AliVii%.�Ult NV. ITI Q0012Jll U.S. 220/SR 1530 Design #U-3310 Sewers -Public Rockingham County The Division's Permits and Engineering Unit acknowledges receipt of your permit application and supporting materials on June 10, 1996. This application has been assii;ned the number listed above. Your project has been assigned to Andy Oakley for a detailed engineering review. Should there be any questions concerning your project, the reviewer will contact you with a request for additional information. Be aware that the Division's regional office, copied below, must provide recommendations from the Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the Division. If you have any questions, please contact Andy Oakley at (919) 733-5083 extension 533. If the engineer is unavailable, you may leave a message on their voice mail and they will respond promptly. PLEASE REFER TO THE ABOVE APPLICATION NUMBER WHEN MAKING INQUIRIES ON THIS PROJECT. cc: Winston Salem Regional Office NC DOT Design Sery Unit (RPW) Sincerely, �cCaskill Caro D. Supervisor, State Engineering Review Group Pollution Prevention Puvs P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer State ai North Carolina ' Department of Environment, Health and Natural Resources Division of Environmental Management Non -Discharge Permit Application (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) GRAVITY SEWER EXTENSION PUMP STATIONS, AND PRESSURE SEWERS GENERAL INFORMATION 1. Applicant's name (please specify the name of the municipality, corporation, individual, etc.): `n Torn of Ellerbe - 2. Print Owners or Signing Official's name and title (the person who is legally responsible for the facility and its C-CSp Rance): Joe Comer, Mayor 3. Mailing address: P - O - Box 310 Ellerbe North Carolina 28338 r- -- City: State. Zip:— -- Telephone Number: ( 910 ) 6 5 2 — 6 2 51 4. Project Name (please specify the name of the subdivision, facility, or establishment - should be consistent with project name on plans, specifications, letters of flow acceptance, Operational Agreements, etc.): (a - 33/0) • (,/S L Lo ,C,�aM S�? /S3o /1/o,c1%X A1-4 o1 f �- O • y /y1•'��s S. Application Date: p 6. Fee Submitted: S 6. County where project is located: n o ck i N,9, 4th II. PERMIT INFORMATION: ) I 1. Application No. (will be completed by DEM): �✓ �7 C�� 1 a 1 2. Specify whether project is: new; modification. 3. If this application is being submitted as a result of a modification to an existing permit. please complete: existing permit number NO0 0 217 8 4 and the issue date November 22, 1993 4. Specify whether the applicant is public or private. III. INFORMATION ON WASTEWATER: 1. Nature of Wastewater. % Domestic/Commercial ; boo % industrial; % Other waste (specify): Please provide a one or two word description specifying theoriginof the wastewater. such as school, subdivision, hospital, commercial, industrial, apartments, etc.: 074,24, 1,,fC �Gti��✓9 SAC �'�i -/S 3. Indicate any parameter(s) (and their concentration) tbat Mll be greater than normal domestic levels: N/A 4. If wastewater is not domestic in nature, what level of pretreatment has been provided to ensure protection of the receiving vaste%vater treatment facility? N/A FORM: GSPSA 11/93 Page 1 of 8 5. If a pretreatment permit is required, has one been issued? Yes X No. If yes, please attach a copy of the pretreatment permit. If No, when will one be issued: ' 6. Volume of wastewater generated by this project (7 gallo: per day.. 7. E� iation of bow wastewater volume was determined: Are, /�c✓a/i'�ie.-' �� 1/A51r 41.4 lf'e- 41, %1 e c ,9 {-ea/ . lf�_r/o c W j .0,v a / 4 .� r�...� s / o o �r �► P VC F/L (- F 1004f •:� -5-E4✓4iL , d a apos rg/ IV. DESIGN INFORMATION: 1. Brief project description: G1 S Z 20 /",;ca 4 - 5" &i,'/{f 2. :Fame of wastewater treatment facility receiving wastewater. Town of El lerbe WWTP a. Facility Permit Number. NCO 0 217 8 4 b. Engineer should provide statement of his evaluation of downstream sewers ability to accept the wastewater: c. Permit Number for sewers immediately downstream: NIA d Pipe diameter of sewers immediately downstream: N/A 3. Summary of sewer pipe to be permitted, by diameter size and pipe material: NSA Diameter (in) Length (linear feet) Pipe Material Circle C or N Factor & Specify Value Minimum Slope (90) Maximum Slope (%) Minimum Velocity (fps) Maximum Velocity (fps) Minimum Cover (in) NOTE: The minimum velocity must not be less than 2 fps. For public sewers the minimum diameter is 8 inches. For private sewers the minimum diameter is 6 inches. 4. .Anchors shall be provided for sewers with slopes greater than 20 %. The anchor spacing shall be a maximum of: 36 feet separation for slopes of 21% to 35`.'c; 24 feet separation for slopes of 36% to 50%; 16 feet separation for slopes greater than 50%. For velocities greater than 15 fps, it is strongly recommended that measures be considered which will protect the sewers and manholes from erosion. For velocities greater than 20 fps, erosion control asures must be specified. For any excessive slopes or velocities that will occur in any sewer line se. iL. wbat measures have been taken to protect the sewer pipe and manholes? NSA FORM: GSPSA 11/93 Page 2 of 8 • • 5. Maximum sewer reach length between manholes: /�li9 linear fee:. 6. This sewer line segment occurs between manhole no. &/A and manhole no. 7. Does the owner/operator have the ability to clean this length? Yes No. For sewer reach lengths gr( than 425 feet, please provide a letter from the owner/operator, stating the ability to clean the specified reach and include equipment specifications. A%/A 8. Sewers subject to existing or planned traffic bearing loads? Yes No. If ves, what measures are being taken to enable the sewers to withstand the loads? &A0 9. Outside drop manholes are provided where invert separations exceed feet (provide for separations > or = 2.5') 10. Identify (by manhole number) those manholes that have drop connections: 111110 11. Maximum allowable infiltration/exfiltrdtion test rate: NlA GPD/pipe diameter inch/mile of pipe. NOTE: Must not exceed 100 GPD/pipe diameter inch/mile of pipe. 12. Minimum separation distances as shown on the plans or addressed in the specifications. If a, b, or c below is no, explain in an attachment (This section must be completed for all collection systems including force mains and pressures sewers): a) 100 ft. horizontal separation from wells or other water supplies? Yes No NIA b) 12 in. vertical separation from storm sewer or ferrous pipe sanitary sewer specified? Yes No i111.9 c) 10 ft. horiz. sep. from water mains or 18 in vertical sep. (water over sewer) or ferrous pipe specified? Yes _ N 13. Are manholes subject to flooding? Yes No. If yes, are manhole rim elevations 1 foot above 100-year flood level. (100 year flood elevation should be indicated on plans) Yes No: Or, are manholes watertight and vented 1 foot above the 100-year flood elevation ( should be shown on plans): Yes No -4//10 14. Identify (by manhole number) those manholes that are vented: 15. Does this project involve any stream crossings? Yes No. If yes, wi 3t precautions or special features have been utilized to ensure protection of the sewer line and not restrict stream flow? Identify the sheet of the plans and station �y11,# number where stream crossings are located: Please note: The Division recommends all stream crossings be located three (3) feet below the stream bed or ferrous material pipe be specified. In addition, all acnal stream crossings must be located above the 25-year flood elevation. Both the 25-year flood elevation and the 100-year flood elevation should be indicated on the plans. 16. Sewers may noj be installed in WS-I watersheds. Are any of the subject wastewater collection systems located in a WS-1 watershed? Yes No. N14 .7. Miscellaneous comments: FORM: GSPSA 111193 Pabe 3 of 8 V . PUMP STATION INFORMATION 1. Pump Station No. or Name: /1,1KLl (A separate sheet 4 of 8 should be submitted for each pump station) 2. Name of closest dowttslope surface waters: /y14 3. Classification of closest do xmslope surface waters: If"1,4 (as established by the Environmental Management Commission & specified on sheet 5 of 8 of this application). In accordance with 15A NCAC ^_H .0219 (h)(3), describe the measures that are being implemented to prevent impacts on downslope surface waters, should a power failure occur at this pump station. NOTE: Alternative power MUST be addressed for every pump station in accordance with the above regulation. " What size pumps are provided: Nli# GPM; and how many? 6. What is the design total dynamic head? AYA feet 7 How many pumping cycles will occur at average daily flow? 111g cycles per hour. NOTE: 15A ?CAC 2H .0219 (b)(2) requires 2 to 8 pumping cycles per hour be achieved at average daily flow. 8. The following items are typically required in the design for pump stations. Check the appropriate blanl: to signify that these items have fin_ provided in the design plans/specifications: Alternate Power Source Wet Well Vented with Screen Fillets in Wet Well Check Valves and Gate Valves Security Fencing Lockable Wet Well Cover Area Light 110V Electrical Convenience Outlet Flood/Buoyancy Protection High Water Alarm (one choice may be specified) Audible and Visual Auto Dialer 9 S f fnrce main to he rermitted by diameter size and pipe material: ummary Diameter (in) � Length (linear feet) Pipe Material High Elevation (ft) I Low Elevation (ft) Minimum Velocity (frs) '.•iaximum Velocity (fps) Mm inimu Cover (in) 0'"',I i6s rSb.3 ,ovC141ff,7 011. 7A) JISr 10. Are air release valves provided at all bioh points along the force main (must be provided where the elevation difference exceeds 10 feet)? yes — no X%g 11. Is pump station subject to flooding? yes _J�no. If yes. what measures are being taken to protect against flooding, 12. If subject to flooding, specify the 100-year i1w..)d elevation: A!Od Feet MSL t3. Are there existing or pianned pump stations doxynst;eani of this station? Yes V "Ilo. if ves, the engineer shal evaluate the aoility of those pump stations to adequately handle the subject ,lows and shall include that evaluation as ar attachment to this applicauon. FOR\i: GSPSA 11/93 Page 4 of 8 This form must be completed by the appropriate _DEM regional office and included as a part of the project submittal information. INSTRUCTIONS TO NC PROFESSIONAL ENGINEER: 1 2 3 4 5 6 7 The classification of the downslope surface waters ( the surface waters that any overflow from the facility wouid flow toward) in which these sewers will be constructed must be determined by the appropriate DEM regional office. Therefore. you are required. prior to submittal of the application package, to submit this form, ith items 1 through 7 completed, to the appropriate Division of Environmental Management Regional Water Qualin, Supervisor (See ?age 8 of 8). At a minimum, you must include an 8.5" by 11" copy of the portion of a 7.5 minute I✓SGS Topographic Map which shows the location of these sewers and the downslope surface waters to which they will be located. ldenufy the closest downslope surface waters on the attached map copy. Once the regional office has completed the classification, reincorporate this completed page and the topographic map into the complete application form and submit the application package. �r1 Applicant (specify name of the municipality, corporation, individual. etc.): 0 I ,G, Name & complete address of engineering fim: h C, ._ Telephone number. ( ) Project name: Name of closest downslope surface waters: County(s) where sewers and surface waters are located: Map name and date: NC Professional Engineer's Seal, Signature, and Date: TO: REGIONAL HATER QUALITY SUPERVISOR Please rrovide me with the classification of the watershed %,here these sewers will be constructed, as identified on the attached ;nap se_ment Name of surface waters: Classification (as established by the Envirorunental Management Commission): ?rorosed classification, if applicable: Si mature of regional office personnel: i All attachrncros must be signed) FORA: GSPSA 11/93 Page 5 of 8 Date: _ THIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL -OF THE APPLICABLE ITEMS ARE INCLUDED WITH THE SUBMITTAL Required hernr a. One original and one copy of the completed and appropriately executed application form. If modifications to the form are required as a result of additional information requests by the Division. the additional information must be transmitted under the signature of the appiicant and the actual modification must be initialed by the INC Professional Engineer. b. Two (2) sets of detailed plans and specifications signed and sealed by a North Carolina Professional Engineer. The plans must include a general location map, a plan view of the sewer extension, a profile of the sewer extension, and must show the proximity of the sewer extension to other utilities and natural features. Specifications may be omitted for delegated authorities. Each sheet of the plans and the first page of the specifications must be signed and sealed. Two (2) copies of the existing permit if a modification. The plans and specifications must not contain phrases (such as: FOR REVIEW ONLY, NOT FOR CONSTRUCTION, etc.) that indicate that they are anything other than final plans and specifications. However, the plans and specifications may contain: FINAL DESIGN - NOT RELEASED FOR CONSTRUCTION. C. Two copies of all calculations, including pump selection, friction calculations, cycle time, pump curves (including system curves applicable with one pump running, two pumps running, three pumps running, etc.), and evaluation of downstream pump stations. These items must be submitted under the signature and seal of the NC Professional Engineer. d. The appropriate permit processing fee. in accordance with 15A NCAC 214 .0205(c)(5). The fee for sewer extensions for nondelegated municipalities is S400. The fee for sewer extensions for delegated municipalities (applies only to those governmental jurisdictions that have specific delegation review authority, as granted by the• Environmental Management Commission) is S200. Name changes without other modifications are 5100. e. If the owner/authority of the wastewater treatment facility (WWTF) that will be accepting the wastewater flow from this project is different from the applicant of rite project, then a letter must be provided from the owner/authority of the WWTF specifying the volume of flow than will be accepted. The ietter should be a recent letter and should refer to the project by the same name as that identified on the application and the pians/specincations. f. If the application is being submitted in the name of a pnvately owned public utility, evidence must be submitted from the 1-tilides Commission which demonstrates that the utili:y is authoriied to hold the franchise for the area to be served. In the case of contiguous service areas, evidence must be erovided from the Utilities Commission aclmowledging these areas are covered tinder an existing franchise. g. A properly executed Operational Aizreemem (original and one copy - form provided by DEW must be submitted if the sewer extension will be serving sinsle family residences. condominiums, mobile homes, or town houses and if the subject sewer extension is owned by the individual residents, a homeowners association, or a developer. h. The downslope surface waters classification must be determined by the appropriate DEM regional office, using page 5 of 8 of this form, prior to the Submittal of the application package to the Water Quality Permits and Engineering Unit. Once the reeional office has completed the classification. page 5 of 8 should be reincorporated into the application package and the entire application package may then be submitted to ',A'ater Quality Permits and Engineering Unit. i. roject should be included with each application package. If necessary for clarity, A cover letter. which briefly describes the p feel free to include attachments to the application form. Such attachments will be considered as part of the application and should be numbered to correspond to the section o which they refer. j. All materials and fees submitted in support of this request for a permit become the property of the Division of Environmental .\4anaeemenc therefore, tf the permit is not issued for any reason, Lhe Division will return submitted materials only at its option. Pa FORA: GSPSA 11/93 15 6 of Name and Complete Address of Engineering Firm: /V C- DO 7 - OE-S/GN JE?v/GEfy�vi ? City: 1PAL E/GN State: /VG yip: 2 76// Telephone Number Professional Engineer's Certification: I, fDQE�T , wle- L eo,< attest that this application for -JW1 164,er' JKWOK f. M. *?EL40cA7?0 has been reviewed by me and is accurate and complete to the best of my latowledge. I funkier attest :hat to the nest of my imowledge the proposed design has been prepared in accordance witb the appiicable regulations. Alit ough certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under Env signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. North Carolina Professional Engineer's Seal. Signature, and Date: A/ l• � SE 2d 19,E flow Applicant's Certification: I. Joe Cnmer attest that this application forLower a Sewer Force Main has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of application are not completed and that if all required supportin; information and attachments are not included, this application packo,- will be returned to me as incomplett7 Signature __ Late May 22 1996 THE CO.WPLETED APPLICATION PACKAGE, i NCLUDING ALL SUPPORTING INFOR.11ATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DIVISION OF ENVIRONMENTAL NIA\AGENIENT . WATER QUALITY SECTION ?ER.NIITS :AND ENGINEERING U. IT ?OST OFFICE 30X 29535 RALEIGH. NORTH CAROLINA 27626-0535 TELEPHONE NUMBER: (919) 733-_083 FORA: GSPSA 11/93 ?ale 7 0f 8 DIVISION OF ENVIRONMENTAL NIANAGENIENT REGIONAL OFFICES (I1/93) Asheville Regional WQ Supervisor 59 Woodfin Place Asheville. NC 28801 (704)251-6208 Fax (704) 251-6452 Washington Regional WQ Supe Post Office Box 1507 -1889 ,Washington. NC 21 (919) 946.6481 Fax (919) 975-3716 Avery Macon Beaufort Jones Buncombe Madison Berne Lenoir Burke McDowell Camden Martin Caldwell Mitchell Chowan Pamlico Cherokee Polk Craven Pasquotank Clay Rutherford CurritUCL• Perquimans Graham Swain Dare Pitt ;Maywood Transylvania Gates Tyrell Henderson Yancy Greene Washington Jackson Hertford Wayne Hyde Faveneville Regional WQ Supervisor Wachovia Building, Suite 714 Favetteville, NC 28301 (910) 486.1541 Fax (910) 486-0707 sor Raleigh Regional WQ Supervisor Post Office Box 27687 Raleigh, NC 27611 (919) 5714700 F ax (919) 571-4718 Chatham Nash Durham Northampton E'dgecombe Orange F ranklin Person Granville Vance Halifax Wake Johnston Wattea Lee Wilson Mooresville Regional WQ Supervisor 919 North Main Street Mooresville. NC 29115 (704)663-1699 Fax(701)663-6040 Wilmington Region. WQ Supervisor- 127 Cardinal Drive Extension Wilmington, NC 28405-3845 (910)395-3900 Fax (910) 350-2004 Anson Moore Alexander Mecklenburg Brunswick New Hanover Bladen Robeson Cabamts Rowan Carteret Onslow Cumberland Richmond Catawba Stanly Columbus Pender Harnett Sampson Gaston Union Duplin Hoke Scotland Iredell Cleveland Montgomery Lincoln Winston-Salem Regional WQ Supervisor 8025 North Point Boulevard. Suite 100 Winston-Salem. NC 27106 (910) 896-7007 Fax (910) 896-7005 Alamance Rockingham Allegbany Randolph .she Stokes Caswell Surry Davidson Watauga Davie Wilkes Forsyth ;-adkin Guilford FORA: GSPSA 11/93 Page 8 of 8 FEB 2 1987 7V ENV. MANAGEMENT State of North Carolina FAYETTEVILLE REG. OFFICE Department of Natural Resources and Community Development Division of Environmental Management 512 North Salisbury Street • Raleigh, North Carolina 27611 James G. Martin, Governor S. Thomas Rhodes, Secretary The Honorable Joe Comer, Mayor Town of Ellerbe P. 0. Box 310 Ellerbe, NC 28338 Dear Mr. Comer: R. Paul Wilms January 23, 1987 Director SUBJECT: Permit No. 14190 Town of Ellerbe Southwest Area Sewer Extension Richmond County In accordance with your application received December 11, 1986, we are forwarding herewith Permit No. 14190, dated January 23, 1987, to the Town of Ellerbe for the construction and operation of the subject wastewater collection system extensions. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. If any parts, requirements, or limitations contained in this permit are unacceptable to you, you have the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings,Post Office Drawer 11666, Raleigh, North Carolina 27604. If you wish to have the hearing before the Hearing Officer with this Department, you must indicate in the petition that you waive the right to have the contested case conducted by a Hearing Officer in the Office of Administrative Hearings, and wish to have the matter conducted in the Department of Natural Resources and Community Development. Unless such demands are made this permit shall be final and binding. One (1) set of approved plans and specifications is being forwarded to you. If you have any questions or need additional informafion concerning this matter, please contact Mr. Asaad Shamsi, telephone number 919/733-5083, ext. 137. Sincerely yours, �y�r. cc: Richmond County Health Dept. R. Paul Wilms .% Fayetteville Regional Office Pollution Prevention Pays Dennis Ramsey PO Box 27687, North Carolina 27611-7687 Tele phone ephone 919-733-7015 Harwood Beebe Co. An Equal Opportunity Affirmative Action Employer ik NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF NATURAL RESOURCES AND COMMUNITY DEVELOPMENT RALEIGH P E R M I T For the Discharge of Sewage, Industrial Wastes, or Other Wastes In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules and Regulations PERMISSION IS HEREBY GRANTED TO Town of Ellerbe Richmond County FOR THE construction and operation of approximately 6,992 lineal feet of 8-inch gravity sewer, 2,683 lineal feet of 6-inch force main; a 180 GPM wet well pump station equipped with duplex submersible pumps and high water alarms to serve Southwest Area of Town of Ellerbe and the discharge of collected domestic wastewater into the Town of Ellerbe's existing sewerage system, pursuant to the application received December 11, 1986 and in conformity with the project plans, specifications, and other supporting data, subsequently filed and approved by the Department of Natural Resources and Community Development and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded, and shall be subject to the following specified conditions and limitations. 1. This permit shall become voidable unless the facilities are constructed in accordance with the approved plans, specifications and other supporting data. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The facilities shall be properly maintained and operated at all times. 4. This permit is not transferable. 5. The sewage and wastewater collected by this system shall be adequately treated in the Town.of Ellerbe Wastewater Treatment Plant prior to being discharged into the receiving stream. 6. Construction of the sewers shall be so scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. .-- Permit No. 14190 Page 2 7. The Permittee shall provide for the pump station and force main the following items: a. Pump-on/pump-off elevations located so that 2-8 pumping cycles may be achieved per hour in the pump station. b. An air relief valve located at all high points along the force main. c. A screened vent for the wet well. d. Fillets located in the wet well at the intersection of the flooring and sidewalls. e. Three (3) feet of cover (minimum) over the force main or the use of ferrous material where three (3) feet cannot be maintained. f. Sufficient devices which will protect the pump station from vandals. g. Flood protection if the pump station is located below the 100-year flood elevation. Permit issued this the 23rd day of January, 1987. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION K. Paul Wilms, Director Division of Environmental.Management By Authority of the Environmental.Management Commission Permit No. 14190 MEMO TO: State Review Group FROM: M. J. Noland ORIGINAL SIGNED BY Regional SupervisoMARION J. NOLAND SUBJECT: Procedure Four (4) APNO08859 Town of Ellerbe Southeast Ellerbe Richmond County Division of Environmental Management Fayetteville Regional Office 1/06/87 Date State Review Group Review Engineer Asaad Shamsi Regional Office Contact Ken Averitte 1) Name of wastewater treatment plant to receive the wastewater: Town of Ellerbe Wastewater Treatment Plant 2) WWTP design capacity .18 MGD 3) NPDES Permit No.: NCO021784 Expiration Date: 03/31/88 4) Compliance Information: Present Treatment plant performance for previous 12 months - beginning 01/12/85 (See attached self -monitoring data) 5) Quantity and type of wastewater from proposed sewers: 15,000 GPD domestic 100% (according of project engineer, D. Slagle) industrial ; other 6) Volume from previously approved projects not yet tributary to WWTP none GPD 7) Regional Recommendations: Approval X Denial KA/gc IA ti Mangy" •� pwa M�a State of North Carolina Department of Natural Resources and Community Development Division of Environmental Management 512 North Salisbury Street • Raleigh, North Carolina 27611 James G. Martin, Governor S. Thomas Rhodes, Secretary t; Dear We acknowledge receipt of the following documents: , 19 permit application - neering plans ifications other. Your project has been assigned to for a detailed engineering review. All project documents will be reviewed with respect to the proposed wastewater facilities. This review will not commit this Division to approving any expansion of these treatment facilities or increase of flowrate in the future. Prior to the issuance of the permit, you will be advised of the recommendations any comments of this Division. You will also be informed of any matter which needs to be resolved. Our reviews are scheduled based on receipt date of complete informations. The items checked below are needed before your project can be reviewed. permit application (copies enclosed) gineering plans (signed and sealed by N.C.P.E.) specifications (signed and sealed by N.C.P.E.) other additional information detailed on attachment The above checked information is needed by r� 166�f 1 If not received, your application package will be returned as incomplete. Please be aware that the Division's a- ftt�-" fl Regional Office must provide RECOMMENDATIONS from the Regional Supervisor or a Proced a Four Evaluation for this project, prior to final action by the Division. If you have any questions, please call the review engineer at this telephone number 919/733-5083. Sincerely, cc: w 0 0 tic Lc � P.O. Box 27687, leigh, North Carolina 27611-7687 Telephone 919-733-4984 An Equal Opportunity Affirmative Action Employer North Carolina Department of Natural Resources and Community Development Environmental Management Commission NON -DISCHARGE PERMIT APPLICATIO • ' in accordance with N.C. General Statutes Chapter 143, Article 21 Applicant (name of board, individual, or others): Board of CaTrnissioners 0 F -t ! Project (name of city, village, town, sanitary district, astabtishment): -- Town Of E1 1 erhP ,v Non -Discharge Treatment/Disposal Facilities Pretreatment Facilities Sewer Collection System (private) Extend Sewer and Sewer Systems (public) NATURE OF WASTEWATER: ® Sewage ❑ Sludge/Industrial Waste rrom tsew•rs, pretreatment facilities, treatment plants): Public sewers and pump station Into (name of tnatm•nt plant): Ellerbe Waste Treatment Plant At (location of treatment plant): D E M USE ONLY Permit Number; C-ounty: Richmond Application Date: Brief Project Description: Construct approximately 6800 feet of 8" sewers, 26 manholes, 2685 feet of 6" force main and a 180 GPM precast suhrnersible pump station in the Southwest Area of the Town. Serving (city, institution, industry): I Town of Ellerbe i Tributary To (name of water course): Toms Branch Name and Complete Address of Engineering Firm: Zip Code: HarwoodBeebeTelephone No. P.O. Box 12060, Florence, SC 29504 (803)669-4491 Treatment Works Capacity to Serve (name of project): For (no, yrs.) t � Avera Dail Gallons SY aons Sewage or Waste Flow; /_�5 ��r) Affect Overall Reduction in Pollution (not applicable for sewer projects): Estimated Costs: Toxic Materials (specify % each, add pages if needed) B. 0. D. (S-day 2d` C) % % Sewers = 142,000-00 Suspended Solids %r Pumping % Station = 38 000.00 TOTAL SOLIDS 96 Treatment % Plant S N/A Other (specify) N/A % f N/A Coliform Bacteria % TOTAL TOXIC MATERIALS Estimated Completion Dore: N/A % , Applicant assures that proposed works will be constructed, supervised, operated and maintained in accordance with approved plans and specifications or approved changes thereto. Print Name: Joe Title: i I�Ia or Mailing Address; F.O.nox �1�Ode Signature: Telephone No. E�le NC 28338 919/65 /6251 INSTR TIONS: 1. Fill-in ALL spaces. If not applicable, enter N/A. 2. Secure appropriate signature (mayor/city manager for municipality; chairman For sanitary district board; owner/proper official of corporation; or legally constituted board or commission in charge of proposed works). A letter of authorization is required from proper official if design engineer or other agent signs application. 3. Submit to N.C. Department of Natural Resources and Community Development, Environmental Management, Raleigh, NC, the original and first copy of application, 2 sets of finalized plans, specifications and other supporting data as required by Commission Rules. NOTE: Application reviews are scheduled on receipt of COMPLETE information. Generally, 30 days are required for pollution abatement projects; 90 days for other projects For Assistance, call the State Central Office 919/733-5083, P.O. Box 27687, Raleigh, N.C. or: *Asheville (704) 253-3341 'Mooresville (704) 663-1699 'Washington (919) 946-6481 *Winston-Salem (919) 761-2351 159 Woodfin Street 919 North Main Street 1502 North Market Street Asheville, NC 28801 Mooresville, NC 28115 Washington, NC 27889 Wins Silos CParkway Extension Winston-SaleSilos NC 27106 *Fayetteville (919) 486-1541 *Raleigh (919) 733-2314 *Wilmington (919) 256-4161 Suite 714 Wachovia Building Box 27687 7225 Wrightsville Avenue Fayetteville, NC 28301 Raleigh, NC 27611 Wilmington, NC 28403