Loading...
HomeMy WebLinkAboutWQ0010096_More Information (Requested)_19941014State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director Robert W. Hites, Jr., City Manager City of Lumberton Post Office Box 1388 Lumberton, North Carolina 28359 Dear Mr. Hites: October 10, 1994 AT4 0 4�jj J� EDEHNR 094 F,� ET�'EVILLE �. Qf�10E Subject: Application No. WQ0010096 Additional Information Request City of Lumberton Freeman Investments, Inc. Sewer Extension Robeson County The Permits and Engineering Unit has completed a preliminary engineering review of the subject application. The following items must be addressed before we can complete our review: 1) The Division requires that a separate application be submitted for the private portion of the subject sewer system. Please revise page 3 of the current application to eliminate the 6 inch private pipe and forward 3 sealed and signed copies of page 3 to my attention. 2) The Division prefers that when calculating the estimated average daily flow from a commercial building that a value of 25 GPD per employee be used for domestic flows. In addition to this value, an estimate of the average daily flow of industrial wastewater (generated from any process or manufacturing which may occur) is required. To assist the Division in its review, please define "non -warehouse facilities" and "warehouse facilities" and describe the types of activities which are proposed to occur in each. If the estimated flow listed on page 2 of the application changes, please forward 3 sealed and signed copies of the revised page to my attention. 3) Your application and plans indicate 429 linear feet of sewer pipe between manhole 2 and manhole 7. Please submit written documentation to the Permits and Engineering Unit which details the method of cleaning pipe lengths greater than 425 feet and the type of equipment to be used. The letter should be signed by a responsible party of the City of Lumberton This letter will be put on file and will be referred to whenever the City of Lumberton submits applications for sewer extensions with distances greater than 425 feet between manholes. 4) Please recheck your calculation of total linear footage of 8 inch sewer line. If the value shown in section 4, number 3 (page 3) of your application is incorrect, please revise this page of your application and forward 3 signed and sealed copies to my attention. 5) So the Division can complete its review, please provide the elevation of the top of the wet well. P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-2496 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper 6) Please provide a letter from the City of Lumberton which documents the response time of personnel and equipment to the pump station in the event of a pump failure. In addition, please document the storage capacity and time until overflow of the wet well. Refer to the subject permit application number when providing the requested information. Please submit three (3) copies of all information to my attention at the address below. Also, please note that failure to provide this additional information on or before November 10, 1994 will subject your application to being returned as incomplete, in accordance with 15A NCAC 2H .0208. If you have any questions on this matter, please call me at (919) 733-5083, ext. 580. Sincerely, Buzz Crosby Environmental Technician State Engineering Review Group cc: Fayetteville Regional Office Permit File WQ0010096 Anderson Engineering and Associates