Loading...
HomeMy WebLinkAboutNCS000315_MONITORING INFO_20190712M'To STORMWATER DIVISION CODING SHEET NCS PERMITS PERMIT NO. DOC TYPE 0 FINAL PERMIT 4 MONITORING REPORTS ❑ APPLICATION 0 COMPLIANCE ❑ OTHER DOC DATE ❑ au I C1 D -1 l YYYYMMDD 04� Univor5olutions July 1, 2019 NC DEQ JUL 12 2019 Division of Energy Mineral and Land Resources Central Files ('Z­t'' + R'Aij-1 1617 Mail Service Center � �f'{ Q f C rdOp,t Raleigh, NC 27699-1617 Re: Semi -Annual Storm Water Sampling Results for 2019 Period 1 Nexeo Solutions, LLC (dlbla Univar Solutions) 3930 Glenwood Avenue Charlotte, Mecklenburg County, North Carolina EPA ID #NCD 061 263 315 To Whom It May Concern: Nexeo Solutions, LLC (Nexeo) (dlbla Univar Solutions) conducted the semi-annual analytical monitoring event for 2019 Period 1 at the facility located at 3930 Glenwood Drive in Charlotte, Mecklenburg County, North Carolina, on June 7, 2019, as prescribed in the National Pollutant Discharge Elimination System (NPDES) stormwater permit (NCS000315). Per the requirements, the stormwater sample was collected from the storm water discharge outfall (SDO) 001 during a measurable storm event that consisted of 1.125 inches of total rainfall, as measured by the onsite rain gauge. The previous measurable storm event was at least 72 hours prior. Enclosed is one signed original and one signed copy of the Discharge Monitoring Report (DMR) for the 2019 Period 1 sampling event. The permittee recorded the required qualitative monitoring observations on the SDO Qualitative Monitoring Report form, which will be retained on site. Should you have any questions or require additional information, please contact me at 704-391- 6877. Sincerely, Nexeo Solutions, LLC (dlbla Univar solutions) �7 TimothyZghtwine Facility Manager Enclosure CC" Chris Byerman, Nexeo Solutions, LLC (dlb/a Univar solutions) Univar Solutions 1 3 Waterway Square Place, Suite a000 I The Woodlands, Texas 77380 1 USA SI'ORNIWATER DISCHARGE OUITALL(SDO) MONITORING REPORT Permit Number NCS000315 FACILITY NAME Nexeo Solution$, LLC (d1bla Univar Solutions) PERSON COLLECTING SANIPLE(S) Kyle Sorenson, Antea Group CERTIFIED i,%,nORATORY(S) Eurofins TestAmerira Lab a 269 Lab 4 Part A: Specific Monitoring Requirements SAMPLES COLLECTED DURING CALENDAR YEAR: 2019 (This monitoring report shall he received by the Division no later than 30 days front the date the facility receives the sampling results from the laboratory.) COUNTY .Mecklenburg _ _ PHONE NO. 7( 04 1391-6877 SIGNATURE OF PERMITTEE OR DESIGNEE REQUIRED ON PAGE 2. Outfull No. Date Sample Collected 50050 SM 25401) SM 4500 H+S SM 4500 H+H SM 5220D Total Flow if a r Total Rainfall TSS pH Temperature OOb i molddlvr MG inches '9 L SU Degrees C mg L 001 06/07119 1.125 13 7.93 22.9 44 Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? Oyes (Don (ifyes, complete Pan 8) Part R: Vehicle %faintrnnnre Activity %1nniturinv Renuirenrents Outftil No. Date Sample Collected 50050 110556 00530 1041400 Total Flow (ifapplicable) 'fetal Rainfall Oil & Crease (ifappl.) Non -polar O&G/1'PII (Method 1664 SGT-HEM), if appl. Total Suspended Solids pfl New Motor Oil Usage rnoldd/yr I%If; inches m /l mg/1 unit gaUnto Form SWU-247, lust revised 6112120)5 Page 1 oi'2 STORM EVENTCHARACfERISTICS: Date 06/07/19 Total Event Precipitation (inches): 1,125 Event Duration (hours): (only ifapplicable—sce permit.) (if more than one storm event was sampled) Date Total Event Precipitation (inches): Event Duration (hours): (only if applicable —see permit.) Mail Original and one copy to: Division of Energy Mineral and Land Resources Attn: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with it system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. 1 am aware that there are significant penalties for submitting false Information, including the possibility of fines and imprisonment for knowing violations." //e? Z/ (Signature of Permi (Dale) Form SWIJ-247, lust revised 602/2015 Page 2 o f 2 STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Permit Number NCS 000315 FACILITY NAME Nexoo Solutions LLC dlbla Univar Solutions PERSON COLLECTING SAMPLE(S) Kyle Sorenson, Antea Group CERTIFIED LABORATORY(S) Eurofins TestAmerica Lab N 269 Lab # Part A: Specific Monitoring Requirements SAMPLES COLLECTED DURING CALENDAR YEAR: 2019 (This monitoring report shall he received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) COUNTY Mecklenburg _ PHONE NO. 7(___0.4 ) 391 fi877 SIGNATURE OF PER %IrfTEE OR DESIGNEE REQUIRED ON PAGE 2. Outfell No. Date Sample Collected 50050 SM 2540D SM 4500 Hr6 SM 4500 H+B SM 5220D Total Flow if a Total Rainfall TSS pH Temperature COD mo/dd! r MG inches mg L Su Degrees C m9 L _ 001 06/07/19 1,125 13 7.93 22.9 44 Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? Oyes (F)no (ifyes, complete Part B) Part B: Vehicle Maintenance Activitv Monitoring Reauirements Outfau No. Date Sample Collected 50050 00556 00530 00400 Total Flow (if applicable) Total Rainfall Oil & Grease (if appL) Non -polar O&GrrPH (Method 1664 SGT-HEM), if a I. Total Suspended Solids pH New Motor Oil Usage mo/dd! r MG inches nwA man unit allmo Form SWU-247, last revised 611212015 Page 1 of 2 STORM EVENT CHARACTERISTICS: Date O6107/19 Total Event Precipitation (inches): 1.125 Event Duration (hours): (only if applicable— see permit.) (if more than one storm event was sampled) Date Total Event Precipitation (inches): Event Duration (hours): (ordy if applicable — see permit.) Mail Original and one copy to: Division of Energy Mineral and Land Resources Atin: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-I617 "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on ury inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there arc significant penalties for submitting false information, including the possibility of fines 'and imprisonment for knowing violations." A l Jy --2 Ao (Signature of Permi (Date) Form SWU-247, last revised 611212015 Page 2 OF 2 ANALYTICAL REPORT Eurofins TestAmerica, Savannah 3 5102 LaRoche Avenue Savannah, GA 31404 Tel: (912)354-7858 Laboratory Job ID: 680-170111-1 � 3 Client Project/Site: Nexeo - Charlotte, N.C. (Outfall 001 ) For: EHS Support, LLC 30475 Middle Creek Circle Daphne, Alabama 36527 Attn: Amy Bauer Authorized for release by. 6/26/2019 1:24:31 PM Jerry Lanier, Project Manager I r. (912)250-0281 jerry.lanier@testamericainc.com �9. t LINKS �s Reyiemi ,your project resultsthrougli Total�4cce5s I Have,a Question A k. The The test results in this report meet all 2003 NELAC and 2009 TNl requirements for accredited i, parameters, exceptions are noted in this report. This report may not be reproduced except in full, Expert and with written approval from the laboratory. For questions please contact the Project Manager at the e-mail address or telephone number listed on this page. This report has been electronically signed and authorized by the signatory. Electronic signature is intended to be the legally binding equivalent of a traditionally handwritten signature. Visit'us'at: www.testamericainccorni ":: Results relate only to the items tested and the samples) as received by the laboratory. Client: EHS Support, LLC Laboratory Job ID: 580-170111-1 Project/Site: Nexeo - Charlotte, N.C. (Outfall 001) Table of Contents Cover Page .............................................. 1 Table of Contents ......................................... 2 Case Narrative ........................................... 3 .............. Sample Summary ......................................... 4 Method Summary ........................................... 5 Definitions/Glossary....................................... 6 Detection Summary ........................................ 7 Client Sample Results ...................................... 8 QC Sample Results ........................................ 9 QC Association Summary ................................... 10 Lab Chronicle ............................................ 11 Chain of Custody .......................................... 12 Receipt Checklists ......................................... 13 Certification Summary ...................................... 14 Eurofins TestAmerica, Savannah Page 2 of 14 6/26/2019 Case Narrative Client: EHS Support, LLC Job ID: 680-170111-1 Project/Site: Nexeo - Charlotte, N.C. (Outfall 001) Job ID: 680-170111-1 Laboratory: Eurofins TestAmerica, Savannah �, I Narrative CASE NARRATIVE Client: EHS Support, LLC Project: Nexeo - Charlotte, N.C. (Outfall 001) Report Number: 680-170111-1 With the exceptions noted as flags or footnotes, standard analytical protocols were followed in the analysis of the samples and no problems were encountered or anomalies observed. In addition all laboratory quality control samples were within established control limits, with any exceptions noted below. Each sample was analyzed to achieve the lowest possible reporting limit within the constraints of the method. In the event of interference or analytes present at high concentrations, samples may be diluted. For diluted samples, the reporting limits are adjusted relative to the dilution required. RECEIPT The samples were received on 0611012019; the samples arrived in good condition, properly preserved and on ice. The temperature of the coolers at receipt was 12.1 C. TOTAL SUSPENDED SOLIDS Sample SDO-001 (680-170111-1) was analyzed for total suspended solids in accordance with SM 25400. The samples were analyzed on 0611712019. The following sample was analyzed outside of analytical holding time due to lab scheduling error: SDO-001 (680-170111-1). No additional analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page. CHEMICAL OXYGEN DEMAND Sample SDO-001 (680-170111-1) was analyzed for chemical oxygen demand in accordance with SM 5220D. The samples were analyzed on 06116/2019. No analytical or quality issues were noted, other than those described above or in the DefinitionslGlossary page, CORROSIVITY (PH) Sample SOO-001 (680-170111-1) was analyzed for corrosivity (pH) in accordance with SM 4500 H+ B. The samples were analyzed on 06/12/2019. This analysis is normally performed in the field and has a method -defined holding time of 15 minutes. This sample(s) was performed in the laboratory outside the 15 minute timeframe. No analytical or quality issues were noted, other than those described above or in the Definitions/Glossary page Eurofins TestAmerica, Savannah Page 3 of 14 6/26/2019 Client: EHS Support, LLC Project/Site: Nexeo - Charlotte, N.C. (Outfall 001) Lab Sample ID Client Sample ID 680-170111-1 SDO-001 Sample Summary Job ID: 680-170111-1 Collected Received Asset ID 0610711911:35 06/10/1910:06 Eurofins TestAmerica, Savannah Page 4 of 14 6/26/2019 Method Summary Client: EHS Support, LLC Project/Site: Nexeo - Charlotte, N.C. (Outfall 001) Method Method Description Protocol SM 25400 Solids, Total Suspended (TSS) SM SM 4500 H+ B pH SM SM 5220D COD SM Protocol References: SM = "Standard Methods For The Examination Of Water And Wastewater' Laboratory References: TAL SAV = Eurofins TestAmerica, Savannah, 5102 LaRoche Avenue, Savannah, GA 31404, TEL- (912)354-7858 Page 5 of 14 Job lfl: 680-170111-1 Laboratory TAL SAV T.AL SAV T.AL SAV RI Eurofins TestAmerica, Savannah 6/26/2019 9M Definitions/Glossary Client: EHS Support, LLC Job ID: 680-170111-1 - Project/Site: Nexeo - Charlotte, N.C. (Outfall 001 ) Qualifiers General Chemistry Qualifier Qualifier Description + H Sample was prepped or analyzed beyond the specified holding time H F Field parameter with a holding time of 15 minutes. Test performed by laboratory at client's request. Glossary Abbreviation These commonly used abbreviations may or may not be present in this report. a Listed under the "D" column to designate that the result is reported on a dry weight basis %R Percent Recovery CFL Contains Free Liquid - CNF Contains No Free Liquid I DER Duplicate Error Ratio (normalized absolute difference) Dil Fac Dilution Factor DL Detection Limit (DODIDOE) DL, RA, RE, IN Indicates a Dilution, Re -analysis, Re -extraction, or additional Initial metalslanion analysis of the sample DLC Decision Level Concentration (Radiochemistry) EDL Estimated Detection Limit (Dioxin) LOD Limit of Detection (DODIDOE) LOQ Limit of Quantitation (DOD/DOE) , l MDA Minimum Detectable Activity (Radiochemistry) MDC Minimum Detectable Concentration (Radiochemistry) U� U�J MDL Method Detection Limit ML Minimum Level (Dioxin) NC Not Calculated ND Not Detected at the reporting limit (or MDL or EDL if shown) PQL Practical Quantitation Limit QC Quality Control RER Relative Error Ratio (Radiochemistry) RL Reporting Limit or Requested Limit (Radiochemistry) RPD Relative Percent Difference, a measure of the relative difference between two paints TEF Toxicity Equivalent Factor (Dioxin) TEQ Toxicity Equivalent Quotient (Dioxin) Eurofins TestAmerica, Savannah Page 6 of 14 6/26/2019 Client: EHS Support, LLC Project/Site: Nexec - Charlotte, N.C. (Outfall 001) Client Sample ID: SDO-001 FAnalyte Total Suspended Solids pH Temperature Chemical Oxygen Demand Detection Summary Result Qualifier RL 13 H 1.6 7.1 HF 22.9 HF 44 10 This Detection Summary does not include radiochemical test results. RL Unit mg/L SU Degrees C mg/L M Job ID: 680-170111-1 Lab Sample ID: 680-170111-1 n I Dil Fac D Method Prep Type 1 SM 2540D Total/NA 1 1 SM 4500 H+ B SM 4500 H+ g TotalINA TotalINA RI 1 SM 5220D Total/NA a Eurofins TestAmerica, Savannah Page 7 of 14 6/26/2019 Client: EHS Support, LLC Project/Site: Nexeo - Charlotte, N.C. (Outfall 001) Client Sample ID: SDO-001 Date Collected: 06107/19 11:35 Date Received: 06/10/19 10.06 General Chemistry A natyte pH Temperature Anatyte Chemical Oxygen Demand Analyte LTotal Suspended Solids Client Sample Results Result Qualifier NONE NONE Unit 7.1 HF SU 22.9 HF Degrees C Result Qualifier RL MOIL Unit 44 10 mg/L Result Qualifier RL RL Unit 13 H 1.6 Page 8of14 mg/L E Job ID: 680-170111-1 Lab Sample ID: 680-170111-1 Matrix: GW 'RI D Prepared Analyzed Oil Fac 06112/19 15:27 1 06112/19 15:27 1 ❑ Prepared Analyzed Dil Fac 06/16119 10:15 1 D Prepared Analyzed Dil Fac 06117/19 10:56 Eurofins TestAmerica, Savannah 6/26/2019 QC Sample Results M Client: EHS Support, LLC Job ID: 680-170111-1 ProjectlSite: Nexeo - Charlotte, N.C. (Outfall 001) Method: SM 2540D - Solids, Total Suspended (TSS) 51 Lab Sample ID: MB 680-57449611 Client Sample ID: Method Blank Matrix: Water Prep Type: TDtalINA Analysis Batch: 574496 MB M8 Analyte Result Qualifier RL RL Unit D Prepared Analyzed Dil Fac Total Suspended Solids <1.0 1.0 mglL 06717119 10:44 1 Lab Sample ID: LCS 680-57449612 Client Sample ID: Lab Control Sample Matrix: Water Prep Type: TotallNA Analysis Batch: 574496 Spike LCS LCS %Rec. � Analyte Added Result Qualifier Unit D %Rec Limits Total Suspended Solids 20,0 17.0 mglL 85 80 - 120 Lab Sample ID: LCSD 680-57449613 Client Sample ID: Lab Control Sample Dup - Matrix: Water Prep Type: Total/NA Analysis Batch: 574,496 Spike LCSD LCSD %Rec. RPD Analyte Added Result Qualifier Unit ❑ %Rec Limits RPD Limit Total Suspended Solids 20.0 19.0 mglL 95 80 - 120 11 25 Method: SM 4500 H+ B - pH Lab Sample ID: LCS 680-57416115 Client Sample ID: Lab Control Sample Matrix: Water Prep Type: Total/NA Analysis Batch: 574161 Spike LCS LCS % Roc. Analyte Added Result Qualifier Unit D %Rec Limits pH 7.01 7.1 SU � 101 63 - 158 Method: SM 5220D - COD Lab Sample ID: MB 680-57443613 Matrix: Water Analysis Batch: 574436 Analyte Chemical Oxygen Demand Lab Sample ID: LCS 680-57443614 Matrix: Water Analysis Batch: 574436 Analyte Chemical Oxygen Demand MB MB Result Qualifier RL MDL Unit <10 10 mg/L Spike LCS LCS Added Result Qualifier Unit 50.0 48.5 mglL Client Sample ID: Method Blank Prep Type: TotallNA D Prepared Analyzed Dil Fac 06/16/19 10:15 1 Client Sample ID: Lab Control Sample Prep Type: TotallNA %Rec. D %Rec Limits 97 90-110 Eurofins TestAmerica, Savannah Page 9 of 14 6/26/2019 QC Association Summary Client: EHS Support, LLC Project/Site: Nexeo - Charlotte, N.C. (Outfall 001) General Chemistry Analysis Batch: 574161 Lab Sample ID Client Sample ID Prep Type 681-170111-1 SDO-001 TotalINA LCS 680-574161/5 Lab Control Sample TotalINA Analysis Batch: 574436 Lab Sample I❑ Client Sample ID Prep Type 680-170111-1 SDO-001 TotalINA MB 680-57443613 Method Blank TotaUNA LCS 680-57443614 Lab Control Sample TotalINA Analysis Batch: 574496 Lab Sample ID Client Sample ID Prep Type 680-170111-1 SDO-001 TotallNA MB 6a0-57449611 Method Blank Total/NA LCS 680-574496/2 Lab Control Sample TotalINA LCSD 680-57449613 Lab Cortrol Sample Dup TotalINA Page 10 of 14 Matrix Matrix GW Water Water Matrix GW Water Water Water Job ID: 680-170111-1 Method Prep Batch _ SM 4500 H+ B SM 4500 H+ B Method Prep Batch SM 5220D SM 5220D SM 5220D Method SM 2540D SM 2540D SM 2540D SM 2540D �J Prep Batch Eurofins TestAmerica, Savannah 6/26/2019 Lab Chronicle Client: EHS Support, LLC Project/Site: Nexeo - Charlotte, N.C. (Outfall 001) Client Sample ID: SDO-001 Date Collected: 06107/19 11:35 Date Received: 06/10/19 10:06 Prep Type TotallNA Job ID: 680-170111-1 Lab Sample ID: 680-170111-1 Matrix: GW Batch Batch Dil Initial Final Batch Prepared ❑ Type Method Run Factor Amount Amount Number or Analyzed Analyst Lab Analysis SM 25400 1 625 mL 1000 mL 574496 06117/19 10:56 JAW TAL SAV Instrument ID: NOEQUdP Total7NA Analysis Ski 4500 H+ B 1 574161 06/12/19 15:27 BTD TAIL SAV Instrument ID MANTECH Total/NA Analysis SM 52201) 1 2 mL 2 mL 574436 06/16/19 10:15 ALG TAL SAV Instrument ID: SPC7 , Laboratory References: TAL SAV = Eurofins TestAmerica, Savannah, 5102 LaRoche Avenue, Savannah, GA 31404, TEL (912)354-7858 Page 11 of 14 Eurofins TestAmerica, Savannah 6/26/2019 TestAmerica Charlotte 2838-8 Queen City Grille Charlotte, MC 28280 Phone: 704.392.1164 Fax: iiotte Chain of Custody Record. hr,�< �I+� <.. 3. a,,R,lorv'Proaram: 1-1Dw )('r,PDts 1 iRLRA rather' TestAmedca T.E LEADER IN UN RON..MP.NNAt TESTING TestAmerica Laboratories, tnc. Client Contact Project Manager: A r— Site Contact: Date: COC No: Company Name: C., 13A-. Tol/Fax: ZS S Lab Contact: Carrier: f o1 COCs Address: Analysis Turnaround Time Z >_ a a E rn 2 a Z a u) rq C a Sampler; Cilyrstateizip: A j CAlERDAq DAYS U L'fORr.1f:G DAYS For tab Use Only: Walk-in Mom Lab Sampling: Phone: z — 3 TAT.1 dtifarml tmm Bolaw _ +❑ 2 ways -1' 1 weo Cl 2 days tarry Fax: ProjerA Name: C(414timv Site: Job r SDG No.: pop Sample Identification Sample Date Sample Time Sample Type (G,Co P G.Gr,b) Matrix of Cont. Sample Specific Notes: G GNV 3 00 68d-17Qi 11 Chain of Custody PravervationUsed:.'1alea, 2=_HCI;-9�tH2SO4;i4cHNO3;"s--NaOH;:GzOther 1 1 1 a - Possible Hazard Identification: Are any samples from a fisted EPA Hazardous Waste? Please list any EPA JVasfe Codes lot the sample, in the Comments Section if she lab is to dispose of the sample. Sample Disposal ( A fee may be assessed if samples are retained longer than 1 month) 0 Return m 0"t by Lab archive fur Months - nnrrstarard [f nawnatoe ❑ Skin Untam ❑ Pusan a rO un..naa n Special InStructlonsiClC Requirements 8 Comments: COD "y �1 144 SO, Ef 7 Custody Seals Inlact: ❑ YeS reo Custody Seat NO,: lee emp. ( ): Obs'd;_L2.V Corrd: nerm ID ND.: Relinquished by: us� Company: An G DaterTime; 7 )� JZ Y Re eiv d by: 1 �t>7t1 YI Company: Dat ime � Relinquished b Compan : DeffiN: Received by: Company: Dal ime. esinquislled by: Company; oat (fim Rece borai Company: `Ct1 DaterTime: -l0-j� I�d6 0 co Login Sample Receipt Checklist Client: EHS Support, LLC Login Number: 170111 List Number: 1 Creator: Elwell, Devin M Question Radioactivity wasn't checked or is <1= background as measured by a survey meter. The cooler's custody seal, if present, is intact. Sample custody seals, if present, are intact. The cooler or samples do not appear to have been compromised or tampered with. Samples were received on ice. Cooler Temperature is acceptable. Cooler Temperature is recorded. COC is present. COC is filled out in ink and legible. COC is filled out with all pertinent information. Is the Field Sampler's name present on COC? There are no discrepancies between the containers received and the COC. Samples are received within Holding Time (excluding tests with immediate HTs) Sample containers have legible labels. Containers are not broken or leaking. Sample collection dateltimes are provided. Appropriate sample containers are used. Sample bottles are completely filled. Sample Preservation Verified. There is sufficient vol, for all requested analyses, incl. any requested MSIMSDs Containers requiring zero headspace have no headspace or bubble is <6mm (114"). Multiphasic samples are not present. Samples do not require splitting or compositing. Residual Chlorine Checked. Answer NIA True True True False False True True True True True True True True True True True True True True N/A True True N/A ! Job Number: 680-170111-1 List Source: Eurofins TestAmerica, Savannah Comment 7,' ; r �7 L Water present in cooler; indicates evidence of melted ice. Cooler temperature outside required temperature ---- criteria. a Eurofins TestAmerica, Savannah Page 13 of 14 6/26/2019 Accreditation/Certification Summary Client: EHS Support, LLC ProjectJSite: Nexeo - Charlotte, N.C. (Outfall 001) Laboratory: Eurofins TestAmerica, Savannah The accreditations/certifications listed below are applicable to this report. Authority Program North Carolina (INWISM State Program EPA Region Identification Number 269 Job ID: 680-170111-1 Expiration Date 12-31-19 Eurofins TestAmerica, Savannah Page 14 of 14 6/26/2019