Loading...
HomeMy WebLinkAbout820430_Odor Control Checklist_20200601RECEIVED Jul 01 2020 NC DEQ/DWR Contra] Oft] e Swine Farm Waste Management — Odor Control Checklist Permit No.: 82-430 te: /18120 INSTRUCTIONS FOR USE Owner Signature: ♦ Odor Control Checklist is required by General Statute 143-215.10C(e)(1) ♦ Check any/all the BMPs you will implement on this facility. Items checked: selected become a rer.;uirement of the CAWMP ♦ Items in bold or pre -selected are required. ♦ Add any site -specific details related to the selected BMPs ♦ Include any other odor control measures not listed ♦ NOTE: Not all BMPs may be cost-effective for every facility. Evaluate each BMP prior to selecting for your facility. Cause/Source BMP Option to Minimize Odor Comments Site Specific Practices FARMSTEAD ♦ Swine Production E Maintain vegetative or wooded buffers at or near property boundary ♦ Improper drainage ® Grade and landscape so water drains away from facilities and prevent ponding E Maintain farm access roads and prevent traffic in waste application area ❑ OtherBMPs— please describe MORTALITY MANAGEMENT ♦ Carcass E Dispose of mortality using method approved Decomposition by NCDA&CS State Veterinarian. Manage According to CAWMP (Mortality Management Checklist) and permit(s). ❑ Put carcasses in refrigerated (or freezer) dead boxes within 24 hours for short-term mortality storage. ♦ Incomplete Incineration ❑ Use incinerators with secondary burners for complete combustion. ❑ Other BMPs — please describe • Traps dust and gases, provides dilution and visual screening • May require third party input/approval • Reduce odors and vectors that occur with stagnant conditions • Prevents spillage during transport and tracking of waste onto public roads • Required by statute and permit • May require third party input/approval • Reduce odors by complete incineration Swine AMOC Page 1 of 6 APPROVED — 7/25/2019 Swine Farm Waste Management — Odor Control Checklist Permit No.: 82-430 Cause/Source BMP Option to Minimize Odor Comments Site Specific Practices HOUSE / BARN — WASTE HANDLING ♦ Flush tanks ❑ Install flush tank covers ♦ Odorous Gases [Z Flush pits at least 4 times per day ♦ Partial microbial ❑ Empty pits at least once every 7 days decomposition ❑ Underfloor flush with pit ventilation ♦ Agitation of wastes ❑ Install/extend fill lines to near bottom of tanks with anti -siphon vents ❑ Install covers on outside waste collection or junction box ❑ Install sump tank covers for lift stations ♦ Ammonia ® Flush/recharge with treated effluent ❑ Treat waste in pits with proven biological or chemical additive ❑ Other BMPs — please describe HOUSE / BARN — FLOOR AND INDOOR SURFACES ♦ Manure covered floors ❑ Scrape manure from alleys into pens daily ® Install fully slotted floor system ® Install waterers over slotted floor area ❑ Install feeders at high end of solid floors ♦ Odorous Gases ❑ Scrape manure buildup from floors and walls ❑ Keep floors dry ❑ Install underfloor ventilation for drying ❑ Replace bedding/scrape at frequency to keep bedding dry ❑ OtherBMPs— please describe • Pit -flush systems • Pit -flush systems • Pit -recharge or "pull -plug" systems • Monitor for any solids accumulation in pit • Will move with other manure via pits • Where applicable • Aids in animal cleanliness • Aids in animal cleanliness • Solid floor/bedding systems Swine AMOC Page 2 of 6 APPROVED — 7/25/2019 Swine Farm Waste Management — Odor Control Checklist Permit No.: 82-430 Cause/Source BMP Option to Minimize Odor Comments Site Specific Practices HOUSE / BARN —VENTILATION ♦ Dust ® Clean fans regularly —specify frequency ♦ Volatile/odorous gases ® Efficient air movement ® Install temperature and humidity sensors to control ventilation ❑ Treat barn exhaust • Examples: biofilters, wet scrubbing, windbreaks . May reduce ventilation rate depending on method ❑ OtherBMPs—please describe HOUSE / BARN — FEED ♦ Dust ❑ Install feed covers ♦ Adsorbed Gases ® Keep outdoor feed storage covered except • Required by rule 1SA NCAC 02D .1802 When necessary to add/remove feed ❑ Minimize free -fall height of dry feed ❑ Install feed delivery downspout extenders to the feed covers ® Remove spoiled/unusable feed on regular basis ❑ Feed pellets instead of dry meal • May require third party input/approval ❑ Use feed additives • May require third party input/approval ♦ Ammonia ❑ Use feed -reduced crude protein diet • May require third party input/approval ❑ OtherBMPs—please describe HOUSE / BARN — GENERAL ♦ Dust ® Install temperature and humidity sensors • Maintain relative humidity at 40 to 65% ♦ Odorous Gases to control ventilation ❑ Use ultraviolet light to treat indoor air ❑ Use indoor or outdoor electrostatic space • Can be used to treat exhaust air charge system ❑ Other BMPs — please describe Swine AMOC Page 3 of 6 APPROVED — 7/25/2019 Swine Farm Waste Management — Odor Control Checklist Permit No.: 82-430 Cause/Source BMP Option to Minimize Odor Comments Site Specific Practices LAGOON / WASTE STORAGE STRUCTURE ♦ Volatile Gases ® Maintain proper lagoon volume • Sufficient liquid volume/depth is required for proper anaerobic treatment ❑ Minimize free -fall height of waste from discharge pipe to lagoon surface ❑ Extend discharge point of pipe to below lagoon • Use caution not to scour or damage lagoon liner liquid level ❑ Maintain proper surface area -to -volume ratio ❑ Use correct lagoon start-up procedures ❑ Aerate for odor control ® Manage sludge levels based on annual sludge survey as required by permit ® Keep spilled feed or foreign debris out of lagoon to prevent excess sludge accumulation ❑ Install/use solids separation system ❑ Use proven biological or chemical additives • Monitor for any increase in rate of solids accumulation ❑ Use permeable lagoon covers (not a digester) ❑ Use impermeable lagoon cover or • Methane can be flared if not utilized anaerobic digester ❑ OtherBMPs— please describe LAND APPLICATION ♦ Odorous gases ® Perform land application in accordance with CAWMP ♦ Wind drift ® Pump intake near lagoon surface ❑ Pump from second stage lagoon ❑ Follow good neighbor policy ❑ Operate at minimum recommended pressure ❑ Increase setbacks beyond those required by statute, rule, or permit Swine AMOC • Required by rule 15A NCAC 02D .1802 -Avoid application on known weekends, special days, or holidays/eves if possible Page 4 of 6 APPROVED — 7/25/2019 Swine Farm Waste Management — Odor Control Checklist Permit No.: 82-430 Cause/Source BMP Option to Minimize Odor Comments Site Specific Practices LAND APPLICATION (CONTINUED) ® Apply during favorable wind conditions, (especially for traveling guns or impact sprinklers) ® When practical, apply waste on sunny days rather than cool, overcast days ❑ When possible, apply waste mid -morning to late -afternoon ❑ For traveling guns, use taper -ring or taper -bore nozzles ❑ For traveling guns, use largest -available nozzle that provides acceptable application uniformity ❑ Replace impact sprinklers with low -drift nozzles on center pivots and linear move systems. ❑ Use hose -drag system ❑ Use injection method for waste application ❑ OtherBMPs— please describe SLUDGE DISPOSAL ♦ Odorous gases ❑ Transport sludge in covered vehicles or tankers ❑ Apply in thin, uniform layers ❑ Incorporate land -applied sludge as soon as practical after application, and in accordance with permit. ❑ Use injection method for sludge application ❑ Dewater sludge prior to application ❑ Use alternatives to land application, such as compost, gasification, energy generation, etc. ❑ OtherBMPs— please describe • Recommend checking predicted average hourly wind speed within 24 hours prior to anticipated start • Allows for vertical dissipation of odor • Allows for better vertical dissipation of odor • Less odor and drift than ring nozzles • Speeds drying and prevents ponding • Required within 48 hours or prior to next rain event, whichever is first, for conventionally tilled bare soils Swine AMOC Page 5 of 6 APPROVED — 7/25/2019 ADDITIONAL INFORMATION Air Management Practices Assessment Tool (AMPAT) AHG-538-A Certification Training for Animal Waste Management Systems: Type A EBAE 103-83 — Lagoon Design and Management for Livestock Manure Treatment and Storage EBAE 128-88—Swine Production Facility Manure Management: Pit Recharge -Lagoon Treatment EBAE 129-88 —Swine Production Facility Manure Management: Underfloor Flush -Lagoon Treatment EBAE Fact Sheet— Calibration of Manure and Wastewater Application Equipment EBAE Fact Sheet — Swine Production Farm Potential Odor Sources and Remedies NC NRCS Standard 359 — Waste Treatment Lagoon NC NRCS Standard 380— Windbreak/Shelterbelt Establishment NC NRCS Standard 422 — Hedgerow Planting NC NRCS Standard 442 — Sprinkler System Nuisance Concerns in Animal Manure Management: Odors and Flies; PRO107 1995 Conference Proceedings Options for Managing Odor: A Report from the Swine Odor Task Force AVAILABLE FROM: www.extension.iastate.edu/ampat/ NC Division of Water Resources www.bae.ncsu.edu www.bae.ncsu.edu www.bae.ncsu.edu www.bae.ncsu.edu www.bae.ncsu.edu www.nres.udsa.gov www.nres.udsa.gov www.nres.udsa.gov www.nres.udsa.gov Florida Cooperative Extension Service NC State University Swine AMOC Page 6 of 6 APPROVED — 7/25/2019