Loading...
HomeMy WebLinkAboutWQ0041703_Application (FTSE)_20200519 (2)May 14, 2020 NCDEQ — Division of Water Resources Mooresville Regional Office 610 East Center Ave., Suite 301 Mooresville, NC 28115 MAY 19 WI -OS MOORESVILLE REGIONAL. OFFICE: RE: POE Fast -Track Application for Gravity Sewer Collection Systems Dear Sir/Madam: Enclosed, please find enclosed the Fast Track Application Package for a private gravity sanitary sewer extension to serve the proposed 29 Townhome POE project located in Charlotte, North Carolina. The enclosed submittal package includes the following: • Application Form (FTA 04-16) (1 original) • Application Form (FTA 04-16) (1 copy) • Application Fee ($480 Check) • Flow Tracking/Acceptance Form (FTSE 04-16) • USGS Topo/Street Level Map • NC Proof of Registered Business If any additional information is needed to process this request, please do not hesitate to contact me at 704.343.0608 Sincerely, Design Resource Group, PA Kevin Hutcherson, EIT Associate 2459 Wilkinson Boulevard, Suite 200 Charlotte, NC 28208 m704.343.0608 SEAL s o C--95 r rn ' C--t 2�16�5+ � i,r�is�UR ru�� a Application Number: "Q_ (to be completed by DWR) ._ MA Y I � All items must be completed or the application will be returned g3Y€ R�//�''5(� OS. I. APPLICANT INFORMATION: I OOIL ESVK E REG04AL OFFICE 1. Applicant's name: byFiorenza Poe NoDa, LLC (company, municipality, HOA, utility, 2. Ap�licant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name: Adam Fiorenza per 15A NCAC 021.01 06(b Title: Principal 4. Applicant's mailing address: 227 East Blvd. City: Charlotte State: NC Zip: 28203- 5. Applicant's contact information: Phone number: 704) 741-6923 Email Address: adam ,byfiorenza.com II. PROJECT INFORMATION: 1. Project name: POE 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Mecklenburg 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.24420 Longitude:-80.8111 5. Parcel ID (if applicable): 08306812 and portion of 08306809 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Matthew Mobley, PE License Number: 034267 Firm: Design Resource Group, PA Mailing address: 2459 Wilkinson Blvd. City: Charlott State: NC Zip: 28208- Phone number: (704) 343-0608 Email Address: matthew@drgrp.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek Permit Number: NC0024970 NC0024945 NCO024937 Owner Name: Charlotte Water V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: inch stem Wide Collection System Permit Number�sbf applicable): WQCS Owner Name(s): FORM: FTA 04-16 Page I of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Develet's Operational Agreement (FORM: DEV been attached? ❑ Yes ❑No ❑N/A 3. If the Applicant is a Home/Proy Owners' Association has an Operational AreernenFORM: HOA) been attached? ❑ Yes [:]No ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) "Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ®No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: 8 Establishment Type (see 02T.01140 Daily Design Flow 0 No. of Units Flow Townhomes 190 gal/day 29 5,150 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total GPD a See 15A NCAC 021' .0114(b), (d), (e)(1 and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. Wastewater generated by project: 5,150 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 14 DIP 8 27 Steel 8 333 PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) - 02T .0305 & I�IDC (Punr Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - ° 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry -15A NCAC 02T .0305(h)(1)(B)® ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry -15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305 O ®Yes ❑ No ➢ 15A NCAC 02T.0305 contains minimum separations that shall be provided for sewers stems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet "Any private or public water supply source, including any wells, WS-I waters of Class I or Class H impounded reservoirs used as a source of drinking water 100 feet "Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ® N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ® N/A ➢ This would include Trout Buffered Streams per 15A NCAC 28.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.04 05(c)(6) (additional permits/certifications)? 0 Yes ❑ No Per 15A NCAC 02T.0105(c)(6) directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes [9 No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 021', the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Desi&,n Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: namefirom Application Item 11I.1.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (Latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. r North Carolina Professional Engineer's seal, signature, and date: �. 4 A V 034267 �4r/, ''•,�N L. 3. Applicant's Certification per 15A NCAC 02T .0106(b): I� Adam McClellan attest that this application for (Signature Authority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 05/06/2020 Signature: Date: FORM: FTA 04-16 Page 5 of 5 State of North Carolina Department of Environmental Quality Division of Water Resources „_ Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Design Resource Group Project Name for which flow is being requested: Poe (Residential) More than one FTSE may be required for a single project if the owner of lite WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek b. WWTP Facility Permit #: NC0024970, NC0024945, NCO024937 All flows are in MGD c. WWTP facility's permitted flow 99.00 d. Estimated obligated flow not yet tributary to the WWTP 10.899 e. WWTP facility's actual avg. flow 72.625 f. Total flow for this specific request 0.0055 g. Total actual and obligated flows to the facility 83.529 h. Percent of permitted flow used 84.4% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / p fl, Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. * * * A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): North Brevard Street Downstream Permit Number: Unknown Page 1 of 6 FTSE 10-18 III. Certification Statement: certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. KA., (330 1/31/2020 Signing Official Signature Date Chief Engineer Title of Signing Official Page 2 of 6 FTSE 10-18 February 3, 2020 Mr. Kevin Hutcherson Design Resource Group 2459 Wilkinson Boulevard Charlotte, NC 28208 SUBJECT: WATER AND SEWER FLOW ACCEPTANCE POE 2716 NORTH DAVIDSON STREET, CHARLOTTE, NC CLTWATER TRACKING# 202039 After an analysis of the sanitary sewer associated with the proposed design of project, 202039, POE, it was determined that there is sufficient capacity to accommodate the proposed sewer flow of 5,510 gallons per day (29 units x 190 gpd/unit) at the connection point(s) indicated on the submitted utility plan for transmission to the Sugar Creek Wastewater Treatment Plant, NPDES permit number NC0024937, for treatment. This acceptance of flow is based upon the existing capacity of the designated publicly owned treatments works. Please see attached NCDEQ-FTSE form. Charlotte Water (CLTWater) agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, PWS ID # 0160010 on file with the Public Water Supply Section of NCDEQ. However, CLTWater cannot guarantee a constant pressure or quality of flow. The applicant should understand that due to the involvement of other agencies and continuing growth of the water system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the CLTWater system is accepted on a first come first served basis. The applicant should understand that this letter is not authorization to construct or extend private water or sewer systems, as the appropriate local or State permits are required prior to construction. if the appropriate authorization to construct permits are not obtained construction has not started within two (2) years of issuance of this flow acceptance and payment for any service connections have not been received within two (2) years of issuance of this flow acceptance letter this flow acceptance approval shall be rescinded, and a new flow acceptance request must be made. The CAP analysis performed determines available capacity within the existing public gravity sewer system. The developer is responsible for any additional private or public sewer infrastructure required to convey flow from the proposed development to the existing public gravity sewer. If you have any questions, please do not hesitate to contact me at (704) 432-5801. Sincerely, Guillermo Anzola Engineering Assistant Charlotte water 5100 Brookshire Blvd, Charlotte, NC 28216 charlottewater.org „ Operated by the City of Charlotte A� Z w -a. AID u /�\ no- mzz 0 & 0 W 64 LU uj LIJ wz� o 8, w 130 (9 WWW O,Z .5;g 11 -.6 L. iz cz) , 9066*906'VOL C069Z VNIIOHVO HIUON'El.UOI8VH3 CAIVA3inos ISV3 LZZZ 011'V(ION 30d VZN3�08A9 VNIlObVO HibON'RUOIWHO 30d -J -R W > W )��} ) � CL F- < LU 2 w 2 1 « N I C14 w w W. z lz �d 2 0 F- U) 0 U) (L 110 > ) I (wr sma,no CNV AS\31SVIla3'\OZ'G0-9CF-_3S AVAINd -10-\03a3N\SilVfH3d 2? SNOLLv3nddV\siN3nnooa\kLu3doMd NOS3HiVVi-100-Cilg\POtfd)ISOS\:D 9066*906'VOL COUZ VNIIOHVO HIHON'3.UOIUVHD OHVA3inoa ISV3 LZZZ 0-11'V(ION 30d VZNMJOIJAB VNIIOHVO HibON'3iiOINVHO .1 I z 9 0 ILto a Q- < 0 I CO r% < r D) , z I z I A oma-vio aNv v4s\3ieviia3\oz-so-go-u3m3s avAlHd -10\03CION\SLIV483d V sNoLLvonddV\SIN3vinOOa\.UN3dOZid NOS3HLVri-LOO--tig\POHd)4SGS\:D 5/5/2020 North Carolina Secretary of State Search Results - File an Annual Report/Amend an Annual Report - Upload a PDF Filing . Order a Document Online - Add Entity to My Email Notification List . View Filings - Print a Pre -Populated Annual Report form • Print an Amended a Annual Report form Limited Liability Company Legal Name Fiorenza Properties, LLC Sosld: 1478757 Status: Current -Active Date Formed: 11 /2/2015 Citizenship: Domestic Annual Report Due Date: April 15th CurrentAnnuaL Report Status: Registered Agent: Fiorenza Properties, LLC Mailing 227 East Blvd Charlotte, NC 28203 Principal Office 227 East Blvd Charlotte, NC 28203 Reg Office 227 East Blvd Charlotte, NC 28203 All LLCs are managed by their managers pursuant to N.C.G.S. 57D-3-20. President Adam R. Fiorenza 301 Fieldbrook Place Charlotte NC 28209 Reg Mailing 227 East Blvd Charlotte, NC 28203 https://www.sosnc.gov/online_services/search/Business_Registration_Results 1 /1 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ❑N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ❑N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) 4,Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ®No ➢ If Yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f) Daily Design Flow',' No. of Units Flow Townhomes 190 gal/day 29 5,510 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 5,510 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5