Loading...
HomeMy WebLinkAboutSW4191201_C03.02 GRADING_5/18/20203 0 z 0 ry cD "'t 0 Cl) 0 0 CY) 0 U H w W U) O J Il 0 U 0 0 0 m O 0 c O rr 0 ti U A) 0 L n 0 N W > E �Q CD 3� CD aD 0 E N �CD N 0 L ca m o71- GENERAL NOTES 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL TOWN OF LENSVILLE & NCOOT STANDARDS & SPECIFICATIONS 2. ALL SPOT ELEVATIONS INDICATED AT CURB AND GUTTER AND ARE DEN07ED TO TOP OF CURB, UNLESS OTHERWISE SHOWN. J. TOTAL DENUDED AREA = 30 AC 4. CONTRACTOR SHALL ADJUST ALL EXISTING VAULTS, MANHOLES, STORM DRAIN STRUCTURES, CLEANOUTS, ETC AS NEEDED TO MATCH FINISH GRADE. 5. ALL BACKFILL, COMPACTION, SOILS TESTING, ETC SHALL BE PERFORMED BY THE OWNERS INDEPENDENT 7ES77NG LABORATORY. (SEE SPECIFICATIONS FOR ADD17IONAL INFORMATION) 6. ALL STORM DRAIN PIPES SHALL BE PROTECTED W17H STONE FILTER PR07EC71ON AFTER STOPPAGE OF WORK EACH DAY. SEE DETAIL ON SHEET C-._. Z EXISTING VEGETATION WITHIN TREE PR07EC71ON AREAS SHALL REMAIN UNDISTURBED. UNLESS N07ED 07HERWISE & ANY AND ALL LANDSCAPING AND EXISTING TREES & SHRUBS TO REMAIN WHICH ARE DAMAGED DURING DEMOL17ION OR CONSIRUC77ON SHALL BE REPLACED BY 7HE CONTRACTOR U71UZING A LICENSED LANDSCAPE CONTRACTOR AT NO AD017IONAL COST TO THE OWNER. 9. 7HE GRADING CONTRACTOR SHALL COMPLY WITH ALL STATE CODES IN OBSERVING EROSION CONTROL MEASURES B07H ON AND OFF -SITE la THE GRADING CONTRACTOR SHALL MAINTAIN ALL EROSION CONTROL DEVICES AFTER EACH RAINFALL EVENT OR AS DIRECTED BY STATE AU7HORI7IES OR THE ARCHITECT. 11. THE GRADING CONTRACTOR SHALL BE RESPONSIBLE FOR OFF -SITE DISPOSAL OF ALL CLEARING AND GRADING WASTE MATERIALS GENERATED DURING CONSTRUCTION AND FOR OBTAINING ALL APPLICABLE PERMI7S FOR OFF -SITE STOCKPILES AND/OR WASTE AREAS 12. THE CROSS -SLOPE ON ALL SIDEWALKS SHALL BE A MAXIMUM OF 2.01 13. CONTRACTOR SHALL VERIFY ALL EXISTING ELEVATIONS WHERE NEW CONSTRUCTION JOIN OR CONNECT TO EXISTING PAVEMENT, CURB AND OTHER RIGID STRUCTURES N07IFY ARCHITECT IF DISCREPANCIES OCCUR. BENCHMARK - TOP OF OPERATING BOLT 900.65 GRADING LEGEND EXISTING CONTOURS FINAL CONTOURS 270.4+ EXISTING SURVEY SPOT ELEVA71ON PPE: PERMANENT POOL ELEVA71ON 270.55 PROPOSED TOP OF CURB SPOT ELEVA71ON II ` III I � IN I: 8- 79 � ' - E - - e II i% i 1 92.29 0- �- �\ II II III i I� I \ II IIII III I II I � Iln I �11 II I , T-00 � 0 I N INV. 894.4�� �� II I g \I j �II O / INV.•I\89.9i1 I \I \ 896 / ` / I i // // Il I III I tbl' PI E BURIE� `------- l i l JItV V.•095.23 - - ++- I III \II \\8ONCONM9�. 5.18" CDR �NV�I 9 28" MAP 5I\I I bI g 859.20T 8" UKN I I / 808.1 -/ / 28" MAPL I \ it I 895.47T 890.97T // // MB, �i I I I I 895.92T 891.48T / / // / / / // // lb 898.78r o �/ �o / // ��o / / / w // / // � I o 895.48T b 890.98T �� II P2 / �F / / / / / A 90 / 898.88T // 870.50T / A92 / 859.20T m 97. /� / / // // Ns cn a e 3160 BM TOPNUT C1 wooeLo _ ao / 7 _ / /� / _z11 I I I8� 97. Q 1 // // // // / // / // // --------------- 6- INV. 96.46 rn� / / / / / / / �� / / / / / --_--- �85 -- I �Cfd -- _------ / __-- III y W $96. Cfd I INV. 31� I Cf III I INV. 4.954 yll I a I II N INV. 895.32 6" UKN I "� I� : 95.73 - - - - - - \ I + I 894.61 7' SIDE SETBACK _ 4" CEDAR I \IMg° I�IV. 893.98 I 12" CHERRY I ^I� 12" OAK71 III III\� I 270.50 PROPOSED GROUND/PAVEMENT ELEVATION 270.50TW PROPOSED FINISHED GRADE AT TOP OF WALL ELEVA71ON 270.50BW PROPOSED FINISHED GRADE AT BOTTOM OF WALL ELEVATION 29 STORM STRUCTURE NUMBER EXISTING STORM DRAIN PIPE PROPOSED STORM DRAIN PIPE FD PROPOSED FOUNDA71ON DRAIN DISCHARGE LINE. SEE ARCH. PLANS FOR DRAIN PIPE LOCATIONS ALONG BUILDING WALLS RD PROPOSED ROOF DRAIN TREE PR07EC71ON FENCE I \ I / / li l i CH m r7 II vWi / ' \ ' `/ W / gG ICRII �\ i HRUB CONSTRUCTION LIMITS \\II IN : 891.73i I I)��NV.• 1891.32 \ \-ql / G / II / / 25' REA� SETBACK 8 9. \ 18 CONC.I Ili 8�0.6 / - / `� \ _'_ _ \ ---- ,>-�-----,---892 , 910�= ��-�---------- _- -----W� -"IZ - � -s � \---------------------------�= 896 q--- DEXTER \E� -�94 INV39 E -- / - \ - 896 E 896 - - - I ----- � � ---- ----- \m I I �� +�- � x \ \I II I C I I CE� I' NII --4 III DRAINAGE STRUCTURE SCHEDULE DRAINAGE STRUCTURE SCHEDULE DRAINAGE STRUCTURE SCHEDULE STRUCTURE NO. PIPE PIPE PIPE PIPE UPPER LOWER UPSTREAM STRUCTURE DATA STRUCTURE NO. PIPE PIPE PIPE PIPE UPPER LOWER UPSTREAM STRUCTURE DATA STRUCTURE NO. PIPE PIPE PIPE PIPE UPPER LOWER UPSTREAM STRUCTURE DATA UP STRM DN STRM SLOPE DIA. LENGTH MATRL INV. INV. TOP ELEV. DEPTH TYPE NOTES UP STRM DN STRM SLOPE DIA. LENGTH MATRL INV. INV. TOP ELEV. DEPTH TYPE NOTES UP STRM DIN STRM SLOPE DIA. LENGTH MATRL INV. INV. TOP ELEV. DEPTH TYPE NOTES (IN) (LF) (FT) (FT) (FT) (1) (FT) (IN) (LF) (FT) (FT) (FT) (1) (FT) (IN) (LF) (FT) (FT) (FT) (1) (FT) A98 A99 1.02% 30 128 RCP 844.10 842.80 859.70 15.60 CB A1020 A1021 2.00% 15 50 RCP 856.00 855.00 860.00 4.00 DI Al A2 1.67% 18 6 RCP 833.20 833.10 837.30 4.10 CB A99 A100 1.08% 30 74 RCP 842.70 841.90 858.30 15.60 CB A1021 A102 2.71% 15 70 RCP 854.90 853.00 860.00 5.10 DI A2 A3 1.43% 18 14 RCP 833.00 832.80 837.30 4.30 CB A100 A101 1.00% 30 130 RCP 841.80 840.50 857.50 15.70 DI A3 A4 0.58% 24 224 RCP 832.70 831.40 838.10 5.40 CB A101 A102 1.00% 30 140 RCP 840.40 839.00 857.50 17.10 DI A1030 A1031 2.50% 15 60 RCP 856.50 855.00 860.00 3.50 DI A4 A5 0.69% 24 58 RCP 831.50 831.10 850.00 18.50 DI A102 A103 1.06% 30 132 RCP 838.90 837.50 859.10 20.20 DI A1031 A103 1.33% 15 180 RCP 854.90 852.50 858.50 3.60 DI A5 A6 0.70% 30 100 RCP 831.00 830.30 849.40 18.40 DI A103 A9 7.04% 30 98 RCP 837.40 830.50 856.00 18.60 DI A6 A7 0.76% 30 92 RCP 830.20 829.50 849.40 19.20 DI B1 B2 1.07% 15 28 RCP 821.00 820.70 824.50 3.50 CB A7 A8 0.71% 30 84 RCP 829.40 828.80 850.00 20.60 DI A920 A92 1.00% 15 40 RCP 855.70 855.30 859.20 3.50 CB B2 B3 2.78% 15 54 RCP 820.60 819.10 824.50 3.90 CB A8 A9 0.75% 30 80 RCP 828.70 828.10 850.00 21.30 DI B3 B4 9.06% 15 32 RCP 819.00 816.10 823.58 4.58 CB A9 A10 0.71% 42 56 RCP 828.00 827.60 852.70 24.70 CB A950 A95 1.00% 15 20 RCP 851.80 851.60 855.30 3.50 CB B4 B5 8.75% 15 40 RCP 816.00 812.50 824.00 8.00 CB A10 All 0.71% 42 28 RCP 827.50 827.30 851.05 23.55 CB All Al2 0.76% 42 92 RCP 827.20 826.50 851.05 23.85 CB A960 A961 1.00% 15 140 RCP 856.00 854.60 859.50 3.50 DI B30 B3 1.00% 15 28 RCP 820.08 819.80 823.58 3.50 CB A961 A962 1.15% 15 26 RCP 854.50 854.20 859.50 5.00 DI A520 A52 1.04% 12 48 RCP 847.00 846.50 850.00 3.00 DI A962 A963 7.58% 15 66 RCP 854.10 849.10 860.00 5.90 DI Cl C2 3.33% 36 210 RCP 847.00 840.00 856.00 9.00 FES A52 A5 7.23% 15 206 RCP 846.40 831.50 849.40 3.00 DI A963 A96 7.22% 15 18 RCP 849.50 848.20 858.90 9.40 CB C3 C4 1.16% 54 86 RCP 804.00 803.00 822.00 18.00 HW A80 A8 1.96% 12 56 RCP 846.40 845.30 849.40 3.00 DI A990 A991 2.50% 15 4 RCP 851.90 851.80 855.40 3.50 CB A991 A99 7.55% 15 102 RCP 851.70 844.00 855.40 3.70 CB D1 D2 4.27% 15 110 RCP 834.50 829.80 836.50 2.00 PE A90 A91 1.00% 15 40 RCP 867.00 866.60 870.50 3.50 CB A91 A92 5.00% 15 224 RCP 866.50 855.30 870.50 4.00 CB A50 A1000 1.00% 12 100 RCP 846.40 845.40 849.40 3.00 DI A92 A93 3.80% 18 108 RCP 855.20 851.10 859.20 4.00 CB A1000 A1001 1.00% 12 100 RCP 845.30 844.30 849.40 4.10 DI A93 A94 1.36% 18 22 RCP 851.00 850.70 855.00 4.00 CB A1001 A1003 0.98% 12 205 RCP 844.20 842.20 849.40 5.20 DI A94 A95 1.11% 24 36 RCP 850.20 849.80 855.00 4.80 CB A1003 A1005 0.80% 15 112 RCP 842.10 841.20 849.40 7.30 DI A95 A96 1.04% 24 222 RCP 849.70 847.40 854.50 4.80 DI A1005 A1006 0.75% 15 40 RCP 841.10 840.80 850.00 8.90 DI A96 A97 1.00% 30 140 RCP 846.90 845.50 859.00 12.10 DI A1006 A10 0.83% 15 36 RCP 840.70 840.40 849.50 8.80 DI A97 A98 1.02% 30 118 RCP 845.40 844.20 861.40 16.00 CB A1010 A100 6.34% 15 142 RCP 854.00 845.00 860.00 6.00 DI LEGEND NOTES CB CATCH BASIN, SEE DETAIL SHEET COZ08 TOP ELEVATION IS TOP OF RIM FOR DI DROP INLET, SEE DETAIL SHEET COZ08 MANHOLES, TOP OF GRATE FOR YARD MH MANHOLE, SEE DETAIL SHEET COZ08 INLETS, AND FINISH GRADE FOR CLEANOUIS PE PLAIN END PIPE. SO STORMWATER CONTROL MEASURE OUTLET, SEE DETAIL SHEET COZ04 ALL FES INLETS & OUTLETS SHALL BE (A 2 STRUCTURE I.D. NUMBER RCP. NOTE: NO EXISTING WETLANDS ARE PRESENT ON THIS SITE. DELINEATION REPORT COMPLETED BY PILOT ENVIRONMENTAL, INC. CATHERINE L. CARSTON (PROJECT MANAGER) & MICHAEL T. BRAME, PWS (PRINCIPAL) GRAPHIC SCALE ( IN FEET ) 1 inch = 40 ft. 661 i- { Piedmont Leaf Lofts 404 East 4th Street, Winston-Salem, NC 27101 Phone 336 722 6152 Fax 336 722 6192 www.mckissickassociates.com Consultants: Consultant Name Civil/Structural/MEP CLH DESIGN, P.A. 400 Regency Forest Drive Suite 120 Cary, North Carolina 27518 Phone: (919)319-6716 Fax: (919)319-7516 LA: C-106, PE: C-1595 Seal: ISSUE LOG Distribution Date No. REVIEW COMMENTS 1 11/8/19 1 VALUE ENGINEERING ITEMS 1 05/11/20 2 Client: WINSTON-SALEM FORSYTH COUNTY SCHOOLS LEWISVILLE MIDDLE SCHOOL Drawing Title: GRADING PLAN AREA 2 Bid Documents Issue Date NOVEMBER 8, 2019 Project Number: Drawn by: 2017-8 RP/KL Drawing Number 3002