Loading...
HomeMy WebLinkAboutWQ0001318_Residual Annual Report 2019 Review_20200518ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Director Mr. Tom Johnson - Water Resources Director City of Lexington 28 West Center Street Lexington, NC 27292 d. � 0.1 i . �9Yw1� NORTH CAROLINA Environmental Quality May 18, 2020 Subject: Review of 2019 Annual Report City of Lexington, Distribution of Class A Residuals Permit No. WQ0001318 Davidson County Dear Mr. Johnson: Division of Water Resources (Division) staff person Caitlin Caudle has completed a review of the 2019 Annual Report. The report reflects compliance with the subject permit. A routine compliance inspection is planned to be completed within the next 12 months. The following item of concern was noted: The annual report was titled "Collection System Annual Report" and included the permit number for the collection system. In the future, annual reports should be titled to denote the Class A Residuals Management Program and include the permit number for the Distribution of Class A Residuals permit. If you have any questions regarding this letter, please contact Patrick Mitchell or me at the letterhead address or phone number, or by email at patrick.mitchellkncdenr.gov or lon.snidernncdenr.gov. Sincerely, Docu SiTgnedl�by: 145B49 2@C 4EA. Lon T. m er, Regional Supervisor Water Quality Regional Operations Section Division of Water Resources, NCDEQ — WSRO cc: Davidson County Environmental Health DWR WQ Central Office — Permit File WQ0001318, WSRO Files North Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1450 W. Hanes Mill Road, Suite 3001 Winston-Salem, North Carolina 27105 336-776-9800 Compliance Inspection Report Permit: WQ0001318 Effective: 08/01/19 Expiration: 06/30/24 Owner: City of Lexington SOC: Effective: Expiration: Facility: City of Lexington DCAR County: Davidson 500 Glendale Rd Region: Winston-Salem Lexington NC 27292 Contact Person: Joseph Charles Shaffer Title: Phone: 336-357-5090 Directions to Facility: System Classifications: LA, Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: NC0055786 City of Lexington - Lexington Regional WWTP Inspection Date: 05/15/2020 Entry Time 12:OOPM Exit Time: 01:OOPM Primary Inspector: Caitlin Caudle Phone: 336-776-9699 Secondary Inspector(s): Patrick Mitchell Reason for Inspection: Routine Inspection Type: Annual Report Review Permit Inspection Type: Distribution of Residual Solids (503) Facility Status: Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions Record Keeping Treatment Sampling Pathogen and Vector Attraction (See attachment summary) Page 1 of 4 Permit: WQ0001318 Owner - Facility: City of Lexington Inspection Date: 05/15/2020 Inspection Type: Annual Report Review Reason for Visit: Routine Inspection Summary: On 05/15/2020 a review of the annual report was completed. The annual report reflected compliance with the subject permit. A site visit was not included in this inspection. The following items of concern were noted: The annual report was titled as "Collection System Annual Report" and included the permit number for the collection system. In the future, annual reports should be titled to denote the Class A Residuals Management Program and include the permit number for the distribution of class a residuals permit. Page 2 of 4 Permit: WQ0001318 Owner - Facility: City of Lexington Inspection Date: 05/15/2020 Inspection Type: Annual Report Review Reason for Visit: Routine Type Yes No NA NE Land Application ❑ Distribution and Marketing Record Keeping Yes No NA NE Is GW monitoring being conducted, if required? ❑ ❑ 0 ❑ Are GW samples from all MWs sampled for all required parameters? ❑ ❑ 0 ❑ Are there any GW quality violations? ❑ ❑ 0 ❑ Is GW-59A certification form completed for facility? ❑ ❑ 0 ❑ Is a copy of current permit on -site? ❑ ❑ ❑ Are current metals and nutrient analysis available? ❑ ❑ ❑ Are nutrient and metal loading calculating most limiting parameters? 0 ❑ ❑ ❑ a. TCLP analysis? 0 ❑ ❑ ❑ b. SSFA (Standard Soil Fertility Analysis)? 0 ❑ ❑ ❑ Are PAN balances being maintained? ❑ ❑ ❑ Are PAN balances within permit limits? ❑ ❑ ❑ Has land application equipment been calibrated? ❑ ❑ ❑ Are there pH records for alkaline stabilization? ❑ ❑ ❑ Are there pH records for the land application site? ❑ ❑ ❑ Are nutrient/crop removal practices in place? ❑ ❑ ❑ Do lab sheets support data reported on Residual Analysis Summary? 0 ❑ ❑ ❑ Are hauling records available? ❑ ❑ ❑ Are hauling records maintained and up-to-date? ❑ ❑ ❑ # Has permittee been free of public complaints in last 12 months? 0 ❑ ❑ ❑ Has application occurred during Seasonal Restriction window? ❑ ❑ ❑ Comment: Pathogen and Vector Attraction Yes No NA NE a. Fecal coliform SM 9221 E (Class A or B) 0 ❑ ❑ ❑ Class A, all test must be <1000 MPN/dry gram Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram ❑ Fecal coliform SM 9222 D (Class B only) ❑ ❑ ❑ ❑ Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram ❑ b. pH records for alkaline stabilization (Class A) ❑ ❑ ❑ ❑ c. pH records for alkaline stabilization (Class B) ❑ ❑ ❑ ❑ Temperature corrected ❑ d. Salmonella (Class A, all test must be < 3MPN/4 gram day) ❑ ❑ ❑ ❑ Page 3 of 4 Permit: WQ0001318 Owner - Facility: City of Lexington Inspection Date: 05/15/2020 Inspection Type: Annual Report Review Reason for Visit: Routine e. Time/Temp on: 0 ❑ ❑ ❑ Digester (MCRT) ❑ Compost Class A lime stabilization ❑ f. Volatile Solids Calculations ❑ ❑ ❑ ❑ g. Bench -top Aerobic/Anaerobic digestion results ❑ ❑ ❑ ❑ Comment: Treatment Yes No NA NE Check all that apply Aerobic Digestion Anaerobic Digestion ❑ Alkaline Pasteurization (Class A) ❑ Alkaline Stabilization (Class B) ❑ Compost ❑ Drying Beds ❑ Other ❑ Comment: Sampling Yes No NA NE Describe sampling: Is sampling adequate? ❑ ❑ ❑ Is sampling representative? ❑ ❑ ❑ Comment: Page 4 of 4