Loading...
HomeMy WebLinkAboutWQ0017302_Permit (Issuance)_20000322State of North Carolina Department of Environment and Natural Resources Division of Water Quality RECEIVED James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director James R. Kirkpatrick Post Office Box 5729 Pinehurst, North Carolina 28374 Dear Mr. Kirkpatrick: 2 4 2000 FAYETTEVILLE REG. ®' FICE March 22, 2000 ilkrz.,NWA 17 NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Subject: Permit No. WQ0017302 Aberdeen Business Park Phase II James R. Kirkpatrick Wastewater Collection System Moore County In accordance with your application received November 22, 1999, and additional information received January 22, 2000, we are forwarding herewith Permit No. WQ0017302 dated March 22, 2000, to James R. Kirkpatrick for the construction and operation of the subject wastewater collection extension. This permit shall void Permit No. WQ0017302 dated September 3, 1999, and shall be subject to the conditions and limitations as specified therein. This permit modifies permit WQ0017302 dated September 3, 1999, by adding a pump station and 6,163 linear feet of force main. Permitting of this project does not constitute an acceptance of any part of the plans and specifications that do not meet 15A NCAC 2H .0200 and the Division of Water Quality's Gravity Sewer Minimum Design Criteria adopted February 12, 1996 unless specifically mentioned herein. Division approval is based on the acceptance of the certification provided by a N.C. Professional Engineer on Page 6 of the subject permit application form. It shall be the permittee's responsibility to ensure the plans and specifications meet the appropriate design criteria and rules. Failure to comply may result in penalties in accordance with North Carolina General Statute 143-215.6A — 143-215.6C, construction of additional facilities, and/or referral of the N.C. Professional Engineer to the licensing board. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding. 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone (919) 733-5083 Fax (919) 715-6048 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper One set of approved plans and specifications is being forwarded to you. If you need additional information concerning this matter, please contact Mr. Michael Mortensen at f919) 733-5083 extension 370. Kerr T. Stevens cc: Moore County Health Department Fayetteville Regional Office, Water Quality Section (NPDES No. NC0037508) Nelson Consulting, Inc. r *f NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO JAMES R. KIRKPATRICK Moore County FOR THE construction and operation of approximately 1,711 linear feet of eight -inch gravity sewer, a 45-GPM pump station with duplex pumps, on -site audible and visual high water alarms, an automatic transfer switch, an on -site generator, an autodialer and approximately 6,163 linear feet of three-inch force main to serve Aberdeen Business Park (Phase 11), and the discharge of 10,500 GPD of collected domestic wastewater into Moore County's existing sewerage system, pursuant to the application received November 22, 1999, and in conformity with the project plan, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall void Permit No. WQ0017302 dated September 3, 1999, and be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, 15A NCAC 2H .0200, the Division of Water Quality's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, the approved plans and specifications, and other supporting data unless specifically mentioned herein. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The facilities must be properly maintained and operated at all times. 4. The sewage and wastewater collected by this system shall be treated in the Moore County's Wastewater Treatment Facility (NPDES No. NC0037508) prior to being discharged into the receiving stream. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality (Division) accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. r Construction of the sewers, pump station(s) and force main shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of ' the State. Upon completion of construction and prior to operation of this permitted facility, a certification and a copy of the record drawings (i.e., as -constructed plans) must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, 15A NCAC 2H .0200, this permit, and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit and provide a final certificate of completion once the entire project has been completed. A copy of the record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Certification and one (1) copy of the record drawings to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. 8. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of five years from the date of the completion of construction. 9. Failure to abide by the conditions and limitations contained in this permit or to construct the facilities in accordance with the conditions of this permit, 15A NCAC 2H .0200, the Division's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, the approved plans and specifications, and other supporting data may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 10. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 11. The Permittee shall provide for the pump station and force main the following items: a. Pump on/off elevations located so that 2-8 pumping cycles may be achieved per hour in the pump station, b. An air relief valve located at all high points along the force main, c. A screened vent for the wet well, d. Fillets located in the wet well at the intersection of the flooring and sidewalls, e. Three feet of cover (minimum) over the force main or the use of ferrous material where three feet cannot be maintained, f. Sufficient devices which will protect the pump station from vandals, and g. Flood protection if the pump station is located below the 100-year flood elevation. h. Adherence with the following minimum separations: (i) Storm sewers (vertical) 12 inches (ii) Water mains (vertical -water over sewer) 18 inches or (horizontal) 10 feet (iii) In benched trenches (vertical) 18 inches (iv) Any private or public water supply source, including any WS-I waters or Class I or Class II impounded reservoirs used as a source of drinking water 100 feet (v) Waters classified WS (other than WS-I), B, SA, ORW, HQW, or SB [from normal high water (or tide elevation)] 50 feet (vi) Any other stream, lake or impoundment 10 feet (vii) Any building foundation 5 feet (viii) Any basement 10 feet (ix) Top slope of embankment or cuts of 2 feet or more vertical height 10 feet (x) Drainage systems (I) Interceptor drains 5 feet (II) Ground water lowering and surface drainage ditches 10 feet (xi) Any swimming pool 10 feet It (xii) Ferrous sewer pipe with joints equivalent to water main standards, shall be used where these minimum separations cannot be maintained. The minimum separation shall however not be less than 25 feet from a private well or 50 feet from a public water supply well; 12. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement wastewater collection facilities. 13. NONCOMPLIANCE NOTIFICATION: The Permittee shall report by telephone to the Fayetteville Regional Office, telephone number (910) 486- 1541, as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within five (5) days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. 14. This permit shall become voidable unless the agreement between James Kirkpatrick and the Moore County Wastewater Treatment Facility for the collection and final treatment of wastewater is in full force and effect. 15. The Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and is a condition of this permit. Noncompliance with the terms of the Operational Agreement shall subject the Permittee to all sanctions provided by North Carolina General Statute 143-215.6A to 143-215.6C for violation of or failure to act in accordance with the terms and conditions of this Permit. Permit issued this t twenty second day of March, 2000. NORTH AROLINA E O NTAL MANAGEMENT COMMISSION ,AKerr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0017302 Permit No. WQ0017302 March 22, 2000 ENGINEER'S CERTIFICATION Partial Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized by the Permittee to observe (periodically, weekly, full time) the construction of the project, Project Name Location and County hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of the Division of Water Quality's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, 15A NCAC 2H .0200, this permit, the approved plans and specifications, and other supporting materials. Signature Date Registration No. The above Engineer's Certification must be completed and submitted to the address below with one (1) copy of the Record Drawings (i.e., as -constructed plans) of the permitted facilities. This project shall not be considered complete and allowed to operate until this Engineer's Certification and the Record Drawings have been submitted. Any wastewater flow made tributary to the permitted facilities prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES DIVISION OF WATER QUALITY WATER QUALITY SECTION NON -DISCHARGE PERMITTING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 A. State of North Carolina Department of Environment and Natural Resources Division.of Water Quality James B. Hunt, Jr., Governor Bill Holman, Secretary Kerr T. Stevens, Director James R. Kirkpatrick PO Box 5729 Pinehurst, NC 28374 Dear Mr. Kirkpatrick: • NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES REECEiVE- a' September 3, 1999 u � P 8 1999 FAYE-i T E1lI LLE REG. OFFICE Subject: Permit No. WQ0017302 James R. Kirkpatrick Aberdeen Business Park Wastewater Collection System Moore County In accordance with your application received August 17, 1999, attached is Permit No. WQ0017302, dated September 3, 1999, to James R. Kirkpatrick for the construction and operation of the subject wastewater collection extension. Please pay attention to Permit Condition 11 which states that "no flow shall become tributary to the subject wastewater collection system until the downstream sewer lines have been permitted, constructed, and certified." This permit shall be effective from the date of issuance until rescinded and you shall be subject to the conditions and limitations as specified in the North Carolina Gravity Sewer Design Criteria adopted February 12, 1996 and the attached permit. In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations, permission is hereby granted for the construction and operation of approximately 1,711 linear feet of 8-inch gravity sewer to serve 21 lots of a proposed office park as part of the Aberdeen Business Park project, and the discharge of 10,500 GPD of collected domestic wastewater into Moore County's existing sewerage system, pursuant to the application received August 17, 1999, and in conformity with the North Carolina Gravity Sewer Design Criteria. The sewage and wastewater collected by this system shall be treated in the Moore County Wastewater Treatment Facility (NPDES Permit No. NC0037508) prior . to being discharged into the receiving stream. This permit shall become voidable unless the agreement between James R. Kirkpatrick and Moore County for the collection and final treatment of wastewater is in full force and effect. The Operational Agreement between the Permittee and the Environmental Management Commission is incorporated herein by reference and is a condition of this Permit. Noncompliance with the terms of the Operational Agreement shall subject the Permittee to all sanctions provided by North 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone (919) 733-5083 FAX (919) 715-6048 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper Carolina General Statutes 143-215.6A to 143-215.6C for violation of or failure to act in accordance with the terms and conditions of this Permit. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6760 Mail Service Center, Raleigh, NC 27699-6700. Unless such demands are made this permit shall be final and binding. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. If you need additional information concerning this matter, please contact Kristin Miguez at (919) 733-5083 extension 524. Sincerely, OYI.A- �t/lG err T. Stevens cc: Moore County Health Department Fayetteville Regional Office, Water Quality Section Nelson Consulting, Inc. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH GRAVITY SEWER COLLECTION SYSTEMS PERMIT This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of the Division of Water Quality Gravity Sewer Design Criteria adopted February 12, 1996. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The facilities must be properly maintained and operated at all times. 4. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality (Division) accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 5. Construction of the gravity sewers shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 6. Upon completion of construction and prior to operation of this permitted facility, a certification and a copy of the record drawings (i.e., as constructed plans) must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the Division of Water Quality Gravity Sewer Design Criteria adopted February 12, 1996, and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. A copy of the record drawings, indicating the facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the Certification and one (1) copy of the "Record Drawings" to the Non -Discharge Permitting Unit,1617 Mail Service Center, Raleigh, NC 27699-1617. 7. A copy of the Record Drawings shall be maintained on file by the Permittee for a minimum of five years from the date of the completion of construction. 8. Failure to abide by the conditions and limitations contained in this general sewer permit or the North Carolina Gravity Sewer Design Criteria may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 9. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement wastewater collection facilities. ' 10. Noncompliance Notification: The Permittee shall report by telephone to the Fayetteville Regional Office, telephone number (910) 486-1541, as soon as possible, but in no case more than 24 hours or on the next working day, following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form w;thin five (5) days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. 11. No flow shall become tributary to the subject wastewater collection system until the downstream sewer lines have been permitted, constructed, and certified. Permit issued this the third day of September, 1999 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Ova, C'GrtLk.) Ke . Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0017302 2 Permit No. W00017302 September 3, 1999 ENGINEER'S CERTIFICATION Partial Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, for the Project Name Location and County Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit, the certificate of coverage, the North Carolina Gravity Sewer Minimum Design Manual, and other supporting materials. Signature Date Registration No. The above Engineer's Certification must be completed and submitted to the address below with one (1) copy of the "Record Drawings" (i.e., as -constructed plans) of the wastewater collection system. This project shall not be considered complete and allowed to operate until this Engineer's Certification and the "Record Drawings" plans have been submitted. Any wastewater flow made tributary to the wastewater collection system prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. NORTH CAROLINA DIVISION OF WATER QUALITY WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT 1617 MAIL SERVICE CENTER RALEIGH, NORTH CAROLINA 27699-1617 3 -I to MEMO TO: FROM: SUBJECT: State Review Group n Ricky Revels Rid �'� Procedure Four (4) WQ0017302 Aberdeen Business Park Phase 1I Sewer Extension -Private James R. Kirkpatrick - Owner Moore County Division of Water Quality Fayetteville Regional Office December 16, 1999 Date State Review Group Review Engineer Mike Mortensen Regional Office Contact Ricky Revels 1) Name of wastewater treatment plant to receive the wastewater: Moore Co. Regional WWTP 2) WWTP design capacity 6.7000 MGD 3) NPDES Permit No. NCO037508 Expiration Date: 11/30/,1999 3 4) Compliance Information: Present treatment plant performance for previous 12 months, beginning 1/98 - 12/98 - Calendar Year Average is 5.3887 MGD (See attached self -monitoring data) 5) Quantity and type of wastewater from proposed sewers: * 10.500 GPD domestic _X industrial other 6) Volume from previously approved projects not yet tributary to WWTP: -440,745-GPD previously approved flows began with WQ0015947 dated 12/11/98 7) Regional Recommendations: Approval _ * X_ Denial * Moore Water and Sewer Authority is presently working on a 201 study. �� Enclosure 12/16/1999 3KEX88/MP COMPLIANCE EVALUATION ANALYSIS REPORT PAGE 1 PERMIT--NC0037508 PIPE--001 REPORT PERIOD: 9801-9812 LOC --- E ?ACILITY--MOORE CO W&SA/MOORE CO WWTP DESIGN FLOW-- 6.7000 CLASS--4 LOCATION --PINE BLUFF REGION/COUNTY--06 MOORE 50050 00310 00530 00610 31616 50060 00300 TGP3B VIONTH Q/MGD BOD RES/TSS NH3+NH4- FEC COLI CHLORINE DO CERI7DPF LIMIT F 6.7000 F 30.00 F 30.0 NOL F 200.0 NOL NOL '9.96 NOL 98/01 5.2806 3.23 5.9 .00 18.2 165.789 1 98/02 6.1892 2.88 5.7 .00 7.6 203.000 10.14 98/03 6.3870 3.20 5.0 .00 15.3 164.545 10.37 1 LIMIT F 6.7000 F 22.00 F 30.0 17.00 F 200.0 NOL NOL NOL 98/04 6.3666 3.35 4.1 .00 10.2 160.000 9.23 98/05 6.0000 3.93 4.7 .00 26.1 173.000 8.39 98/06. .5.4466 3.94 4.1 .00 23.3 87.727 8.06 1 98/07 5.17i1 4.22 5.0 .00 21.1 149.130 7.82 98/08 5.0935 3.89 4.4 .00 28.1 111.428 7.96 98/0.9 4.8233 6.19 10.0 .00 54.6 155.238 8.16 1 98/10 4.8838 6.51 7.2 .00 33.1 282.954 8.25 LIMIT F 6.7000 F 30.00 F 30.0 NOL F 200.0 NOL NOL NOL 98/11 4.5233 6.80 8.3 .00 9.5 127.777 8.74 98/12 4.4967 5.52 8.4 .12 16.0 127.142 9.46 1 AVERAGE 5.3887 4.47 6.0 .01 21.9 158.977 8.87 1 MAXIMUM 9.8000 11.80 26.0 1.79 4400.0 1145.000 13.60 1 MINIMUM 4.0000 LESSTHAN LESSTHAN LESSTHAN LESSTHAN LESSTHAN 5.60 MG/L 1 PASS/FAI UNIT MGD MG/L MG/L MG/L #/100ML UG/L 3KEX88/MP 12/16/1999 COMPLIANCE EVALUATION ANALYSIS REPORT PAGE 2 PERMIT--NC0037508 PIPE--001 REPORT PERIOD: 9801-9812 LOC --- E FACILITY--MOORE CO W&SA/MOORE CO WWTP DESIGN FLOW-- 6.7000 CLASS--4 LOCATION --PINE BLUFF REGION/COUNTY--06 MOORE KONTH LIMIT 98/01 98/02 00010 00400 00600 00665 00720 01042 01077 01092 TEMP PH TOTAL N PHOS-TOT CYANIDE COPPER SILVER ZINC NOL 9.0 6.0 NOL NOL NOL NOL NOL NOL 15.55 7.7-6.8 13.500 1.4000 .0000 8.0000 .0000 21.0000 14.60 7.8-7.3 11.000 1.6500 98/03 15.77 7.9-7.1 15.250 1.3700 LIMIT NOL 9.0 6.0 NOL NOL 98/04 18.47 7.9-7.4 8.130 2.4000 98/05 20.95 7.9-7.4 14.250 2.0500 98/06 23.90 7.9-7.3 12.760 2.2600 98/07 25.87 7.8-7.1 21.140 2.7000 98/08 26.09 7.8-7.4 15.170 1.9500 98/09 98/10 LIMIT 98/11 98/12 25.63 7.9-7.4 17.310 2.0200 22.96 7.9-7.1 14.630 1.5900 NOL 9.0 6.0 NOL NOL 20.36 7.9-6.8 18.210 1.9700 18.32 7.9-6.9 16.100 2.2300 .0000 9.0000 .0000 �8.0000 NOL NOL .0000 7.5000 .0000 21.5000 .0000 19...0000 NOL NOL .0000 19.5000 .0000 11.0000 .0000 26.0000 .0000 8.5000 .0000 20.0000 .0000 10.0000 .0000 21.5000 .0000 6.5000 .0000 21.0000 .0000 10.0000 3.0000 25.0000 .0000 7.5000 NOL NOL .0000 9.5000 .0000 9.0000 .0000 19.0000 NOL NOL .0000 20.0000 .0000 20.0000 AVERAGE 20.70 14.787 1.9658 .0000 8.7083 .2500 21.1250 MAXIMUM 27.00 7.900 21.140 2.7000 14.0000 6.0000 33.0000 MINIMUM 14.00 6.800 8.130 1.3700 6.0000 17.0000 UNIT DEG.0 SU MG/L MG/L UG/L UG/L UG L UG/L