Loading...
HomeMy WebLinkAboutWQ0010586_Application_19950208• •.State.of No [Departmen Health and t rth Carolina of Environment, Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director EXEHNF= RECEIVED February 8, 1995 FEB 13 1995 MR BOBBY B. TEAGUE TOWN OF SOUTHERN PINES ENV. MANAGEMENT 140 MEMORIAL PARK COURT FAYETI"EVILLE REG. OFFICE SOUTHERN PINES, NORTH CAROLINA 28387 Subject: Application No. WQ0010586 Talamore Sewers -Public Moore County Dear MR TEAGUE: The Division's Permits and Engineering Unit acknowledges receipt of your permit application and supporting materials on February 2, 1995. This application has been assigned the number listed above. PLEASE REFER TO THE ABOVE WATER QUALITY NUMBER WHEN MAKING INQUIRES ON THIS PROJECT. Your project has been assigned to Liz Kovasckitz for a detailed engineering review. Should there be any questions concerning your project, the reviewer will contact you with an additional information letter. Be aware that the Division's regional office, copied below, must provide recommendations from the Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the Division. If you have any questions, please contact Liz Kovasckitz at (919) 733-5083. cc: Fayetteville Regional Office Hobbs Upchurch & Associates Sincerely, U -- '� Carolyn cCaskill Supervisor, State Engineering Review Group Pollution Prevention Pays P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer I r: i2J MEMO TO: State Review Group FROM: Ricky Revels Environmental Technician IV SUBJECT: Procedure Four (4) WQ0010586 Talamore Sewer Extension - Public Town of Southern Pines Moore County Division of Environmental Management Fayetteville Regional Office 2 27 95 Date State Review Group Review Engineer Liz Kovasckitz Regional Office Contact Ricky Revels 1) Name of wastewater treatment plant to receive the wastewater: Moore County Regional Wastewater Treatment Plant 2) WWTP design capacity 6_7 MGD 3) NPDES Permit No.: NCO037508 Expiration Date: 4 30 97 4) Compliance Information: Present treatment plant performance for previous 12 months - beginning 1194 (See attached self -monitoring data) 5) Quantity and type of wastewater from proposed sewers: 9,000 GPD domestic 100% industrial other 6) Volume from previously approved projects not yet tributary to WWTP 1,209,497 GPD 7) Regional Recommendations: Approval X Denial _ RR/rr Enclosure WASEl V State of North Carolina Department of Environment, Health, and Natural Resources Division of Environmental Management Non -Discharge Permit Application (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) GRAVITY SEWER EXTENSION I. GENERAL INFORMATION: 1. Applicant (corporation, individual, or other): Town of Southern Pines 2. Print Owners or Signing Official's Name and Title (the person who is legally responsible for the facility and its compliance): Bobby B. Teague. P.E. . Director of Public Works 3. Mailing Address: Town of Southern Pines, 140 Memorial Park Court City. Southern Pines State: NC Zip: 28387 Telephone No.: 910 692-7021 4. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans/specs., letters of flow acceptance, Operational Agreements, etc.): Phase II Talamore Lot Development 5. Application Date: January 10, 1995 6. Fee Submitted: $ 400.00 7. County where project is located: Moore II. PERMIT INFORMATION: 1. Permit No. (will be completed by DEM): 2. Specify whether project is: X new; renewal*; modification. *If renewal, complete only sections I through III and applicant signature (on pg.5). Submit only pgs. 1, 2, 5 (original and 3 copies of each). Engineer signature not required for renewal. 3. If this application is being submitted as a result of a renewal or modification to an existing permit, list the existing permit number and issue date 4. Specify whether the applicant is x public or private. FORM: GSEA 4/91 Page 1 of 6 GRAVITY SEWER EXTI'ENSION PAGE 2 (4/91) III. INFORMATION ON WASTEWATER: 1. Nature of Wastewater. 100 % Domestic; % Commercial; % Industrial; % Other waste (specify): 2. Please provide a one or two word description specifying the origin of the wastewater, such as school, subdivision, hospital, commercial, industrial, apartments, etc.: Residential Subdivision 3. Indicate any parameter (and its concentration) that will be greater than normal domestic levels: None 4. 5. 21 If wastewater is not domestic in nature, what level of pretreatment has been provided to ensure protection of the receiving wastewater treatment facility? N/A Volume of wastewater generated by this project: 9,000 gallons per day Explanation of how wastewater volume was determined: 25 lots x 360 GPD (3 bedrooms x 120 GPD) IV. DESIGN INFORMATION: 1. Brief project description: 8 inch gravity collection sewer extensions in new residential golf course lot development — Areas 2 & 3 of Phase II 2. Name of wastewater treatment facility receiving wastewater: Moore County Wastewater Treatment Plant a. Facility permit no.: NPDES NC 0037508 b. Engineer should provide statement of his evaluation of downstream sewers to accept the wastewater: Adequately sized to accept this increase in wastewater flow 2of6 - - + - GRAVITY SEWER EXTENSION PAGE 3 (4/91) 3. Summary of sewer pipe by diameter size and pipe material. Indicate here whether C factor or fact is used and circle C or N below: 0.013 Dia. Length Pipe C or(N) Min. Max. Minimum Max. Minimum (In.) (Lin. Ft) Material Factor Slope % Slope % Velocity (fps) Vel.(fps) Cover (in) A— Z562 PVC 0.013 0.40 11.91 2.2 _ 12.0 36 8 461 DIP Jj-1.3 n:2.2 2.2 12 NOTE: The minimum velocity must not be less than 2 fps. For public sewers the minimum diameter is 8 inches. 4. Anchors shall be provided for sewers with slopes greater than 20 %. The anchor spacing shall be as follows: a. 36 feet separation for slopes of 21% to 35%; b. 24 feet separation for slopes of 36% to 50%; c. 16 feet separation for slopes of 50% and greater. For velocities greater than 15 fps, it is strongly recommended that measures be considered which will protect the sewers and manholes from erosion. For velocities greater than 20 fps, erosion control measures must be specified For any excessive slopes or velocities that will occur in any sewer line segment, what measures have been taken to protect the sewer pipe and manholes? N/A 5. Maximum sewer reach length between manholes: 350 linear feet. 6. This sewer line segment occurs between manhole no. A- 2 and manhole no. B 7. Does the owner/operator have the ability to clean this length? x Yes No. 8. Sewer subject to existing or planned traffic bearing loads? Yes X No. If yes, what measures are being taken to enable the sewers to withstand the loads? 9. Outside drop manholes are provided where invert separations exceed: 2.0 feet. 10. Identify (by manhole number) those manholes that have drop connections: None 3 of 6 - Qr�.AYITY SEWER EXTENSION PAGE 4 (4/91) - 11. Maximum allowable infiltration/exfiltration test rate: Note: Must not exceed 200 GPD/ pipe dia. in./ mile. 100 GPD/ pipe dia. in./ mile. 12. Minimum separation distances as shown on the plans or addressed in the specifications: a) 100 ft. horizontal separation from wells or other water supplies? g Yes _ No b) 12 in. vertical separation from storm sewer or ferrous pipe sanitary sewer specified? x Yes —No c) 10 ft horizontal separation from water mains or 18 in. vertical separation (water over sewer) or ferrous pipe specified? X Yes —No 13. Are manholes subject to flooding? _Yes g No 14. If yes, are manhole rim elevations 1 foot above 100-year flood level, —Yes —No (100 year flood elevation should be indicated on plans) 15. Or are manholes watertight and vented 1 foot above the 100-year flood elevation ( should be shown on plans): _Yes _ No 16. Identify (by manhole number) those manholes that are vented: N/A 17. Does this project involve any stream crossings? _ yes X no. If yes, what precautions or special features have been utilized to ensure protection of the sewer line and not restrict stream flow? Identify the sheet of the plans and station number where stream crossings are located: THIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL OF THE APPLICABLE ITEMS ARE INCLUDED WITH THE SUBMITTAL Required Items a. One original and three copies of the completed and appropriately executed application form. b. Three sets of detailed plans and specifications signed and sealed by a North Carolina Professional Engineer. The plans must include a general location map, a plan view of the sewer extension, a profile of the sewer extension, and must show the proximity of the sewer extension to other utilities and natural features. Specifications may be omitted for delegated authorities. Each sheet of the plans and the first page of the specifications must be signed and sealed. Three copies of the existing permit if a renewal or modification. C. The appropriate permit processing fee, in accordance with 15A NCAC 2H .0205(c)(5). d. If the owner/authority of the wastewater treatment facility (WWTF) that will be accepting the wastewater flow from this project is different from the applicant of the project, then a letter must be provided from the owner/authority of the WWTF specifying the volume of flow that will be accepted. The letter should be a recent letter and should refer to the project by the same name as that identified on the application and the plans/specifications. C. An Operational Agreement (original and two copies) must be submitted if the sewer extension will be serving single family residences, condominiums, mobile homes, or town houses and if the subject sewer extension is owned by the individual residents, a homeowners association, or a developer. 4 of 6 .,� ti . GRAVITY SEWER EXTENSION. PAGE 5 (4/91) Name and Complete Address of Engineering Firm: Hobbs, Upchurch & Associates, P.A. 290 S.W. Broad Street City: Southern Pines State: NC Zip: 28387 Telephone No. 910/692-5616 Professional Engineer's Certification: 1, Charles D. Heiser , attest that this application for Phase II Talamore Lot Development has been reviewed by me and is accurate and complete to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. North Carolina Professional Engineer's Registration No. Print Name of Engineer Charles D. Heiser 10614 Seal and Signature (specify date): 17 Applicant's Certification: r ` I, Bobby B. Teague , attest that this application for Phase II Talamore Lot Development has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned as incomplete. _ Signature 1 �- Date Z'-f J , r, `I 5 THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATIONAND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 512 NORTH SALISBURY STREET RALEIGH, NORTH CAROLINA 27626-0535 . TELEPHONE NUMBER: 919/733-5083 5of6 G1EAVITY SORER EXTENSION, ~' PAGE 6 (4/91) PERMIT APPLICATION PROCESSING FEES (effective October 1,1990) CATEGORY NEW APPLICATIONS/ RENEWALS WTI TOUT MODIFICATIONS MODIFICATIONS > 1,000,000 GPD Industrial $400 Domestic/Cooling Water $400 10,001 - 1,000,000 'GPD Industrial $400 Domestic/Cooling Water $400 1,001 - 10,000 GPD Industrial $400 Domestic/Cooling Water $400 < or = 1,000 GPD and Single Family Dwelling $240 Sludge < or = 300 Acres $400 Sludge > 300 Acres $400 Sewer Extensions (nondelegated) $400 Sewer Extensions (delegated) $200 Closed -Loop Recycle or Evaporative $400 $300 $300 $250 $250 $200 $200 $120 $250 $250 0 0 $200 NOTE: The Fees for Soil Remediation Projects are the same as for Sludges. Under the Sewer' Extension' Fee, "delegated to municipalities" applies only to those governmental jurisdictions that have specific delegation review authority, as granted by the , Division of Environmental Management. 6of6 OFFICE OF SYSTEM SUPERINTENDENT February 1, 1995 oozE VVQLEz cSEUTEz C_-4uELuEcJ Water Pollution Control System P. O. Box 813 Pinebluff, North Carolina 28373 O.W.A. 104 198 �o o t' "C o u val Ms. Carolyn McCaskill, Supervisor State Engineering Review Group N.C. Dept. of Environmental Health & Natural Resources Division of Environmental Management P.O. Box 27687 Raleigh,N.C. 27611 Re: Gravity Sewer Extension Permit Application Talamore-Phase II Development Town of Southern Pines HUA NO: SP9427 Dear Ms. McCaskill: TELEPHONE: 910-281-3146 FAX: 910-281-2047 The Moore County Water Pollution Control Facilities hereby agrees to conditionally accept up to 9,000 gallons per day of wastewater from the referenced project in accordance with request of January 30, 1995 by Hobbs,Upchurch & Associates, P.A., of Southern Pines, N.C. Upon completion of the referenced project, the applicant's engineer is to provide this office with the following items: 1. Infiltration in gallons per day. 2. Certification of completion as defined by N.C. Statutory Requirements #143-215.1; Section 2-H.0220. 3. Complete set of As -Built drawings as approved by Engineer. 4. All shop drawings/ 0 & M Manuals, Diagrams, Illustrations, schedule & brochure which illustrate how specific portions were fabricated and installed. After Moore County has received a copy of the certification of completion, our office will provide a final acceptance statement.. � LEC incerel_y,y� ry A. Frick System Superintendent emb `iU OFFICE] I pc: Mr. Jim Tarnow, P.E., Moore Water and Sewer Authority Mr. Mitch Coleman, Exec. Director, Moore Water and Sewer Authority Mr. Bob Teaque, Public Works Director, Town of Sou. Pines. Mr. Charles Heiser, P.E., Hobbs, Upchurch & Assoc, P.A. Kerr T. Stevens, Dept. of EHNR, Fayetteville Mr. W. David McNeill, Jr., County Manaqer