Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0009621_Application_19940622
I State of North .Carolina Department of Environment, Health and Natural Resources Division of Environmental Management A�� James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary ID C F1 A. Preston Howard, Jr., P.E., Director C June 21, 1994 1 ' Jul 22199-44 ' MAYOR KATRINA MORRISON TOWN OF TAYLORTOWN PO BOX 1274 PINEHURST, NORTH CAROLINA 28374 Dear MAYOR MORRISON: ENV. 1 k,,\ iAGEMENT FXYETTEViLLE REG. ©FFICQ Subject: Application No. WQ0009621 Utility Imp. - CDBG Sewers -Public Moore County The Division's Permits and Engineering Unit acknowledges receipt of your permit application and supporting materials on June 20, 1994. This application has been assigned the number listed above. PLEASE REFER TO THE ABOVE WATER QUALITY NUMBER WHEN MAKING INQUIRES ON THIS PROJECT. Your project has been assigned to Randy Kepler for a detailed engineering review. Should there be any questions concerning your project, the reviewer will contact you with an additional information letter. Be aware that the Division's regional office, copied below, must provide recommendations from the Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the Division. If you have any questions, please contact Randy Kepler at (919) 733-5083. cc: Fayetteville Regional Office Hobbs Upchurch & Associates 31 erefy, 0 4�f� Caro yn Mc askill Supervisor, State Engineering Review Group Pollution Prevention Pays P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer B . V � � a MEMO TO: State Review Group FROM: Ricky Revels R,�'s Environmental Technician SUBJECT: Procedure Four (4) WQ0009621 Utility Imp. - CDBG Sewer Extension - Public Town of Taylortown/Pinehurst Moore County Division of Environmental Management Fayetteville Regional Office 7114194 Date State Review Group Review Engineer Randy Kepler Regional Office Contact Ricky Revels 1) Name of wastewater treatment plant to receive the wastewater: Moore County Regional Wastewater Treatment Plant 2) WWTP design capacity 6_7 MGD 3) NPDES Permit No.: NC0037508 Expiration Date: 04 30 97 4) Compliance Information: Present treatment plant performance for previous 122 months - beginning 6/01193 (See attached self -monitoring data) 5) Quantity and type of wastewater from proposed sewers: 29.040 GPD domestic 100% industrial other 6) Volume from previously approved projects not yet tributary to WWTP 700,678 GPO 7) Regional Recommendations: Approval X Denial RR/rr Enclosure . . - . . . ^ , . . GKEX88/MP ^ . . 1/94 COMPLIANCE EVALUATION ANALY%I% REPORT PA�E i PER MIT--NC0037508 PIPE .... .... 0Oi REPORT PERIOD 93O6-9405 LOC.... .... .... E FACILITY--MOORE COUNTY WWTP DE%IcN FLOW-- 6.7OOO CLA%%--4 LOCATION--CARTHA�E REGION/COUNTY--O6 MOORE 50050 003i0 0O53O O06iO 316i6 50O6O O030O 1,CaP3B MONTH Cl /M�D BOD RE%/T%% NH3+NH4- FEC COLI CHLORINE DO CERI7DPF LIMIT F 6.7000 F 22.00 F 3O.0 i7.O0 F 20O.O NOL NOL NOL 93/06 ' 3.9766 3.97 5.i .iO 44.9 .0i5 7.85 i 93/07 4.O387 4.O9 4.2 .iO 22.8 .066 7.72 i 93/O8 4.i87O 3.57 5.O .iO 43.4 .O50 8.O7 93/09 4.i566 3.3 6.6 .i0 53.4 .O54 8.16 i 93/1O 3.6967 5.21 18.4 .iO 66.8 .056 8.65 LIMIT F 6.7O00 F 30.00 F 3O.O NOL F 2O0.0 NOL FCl 93/ii 3.6766 5 .i9 6.3 .10 38.5 .O53 93/i2 3.6548 4.60 5.8 .i8 i9.9 .i53 i 94/Oi 4.i008 6.48 7.9 .iO i3.9 .O82 94/02 4.0535 12.38 8.6 .10 32.7 .077 94/03 4.1419 6.48 8.4 .i0 24.4 .094 i LIMIT F 6.70O0 F 22.O0 F 3O.0 i7.00 F 200.O NOL NOL NOL 94/O4 3.9566 3.75 6.2 .iO 57.3 .O53 7.i6 94/05 3.89O3 4.46 9.1 45.9 .O83 7.39 AVERAClE 3.96O7 5.28 6.9 .ii 38.6 .069 7.85 i MAXIMUM 8.80O0 i22.4O 28.2 1.74 962.O .838 ii.0O 2 MINIMUM 2.4O00 2.00 i.4 .iO 3.0 .OiO 4.7O i UNIT MGD M�/L M�/L M�/L �/i0OML M�/L M�/L PA%%/FAI 5.3& N*GD � ~-'- �� �"� ��A �&°°M4��� � ��� �� °�*� ^ °� °�� 1*�4 Wwa a^wm~~``/`~~~~ ' ~' � �"*,� � . ° . ` . . !LKEX88/MP ^ 07/0i/94 COMPLIANCE EVALUATION ANALYSIS REPORT PAGE 2 PERMIT--NC0037508 PIPE--OOi REPORT PERIOD: 9306-9405 LOC--- E FACILITY--MOORE COUNTY WWTP DESIGN FLOW-- 6.7000 CLA%%--4 LOCATION--CARTHAGE REGION/COUNTY--06 MOORE 000i0 00400 00600 00665 08720 OiO27 01034 01042 MONTH TEMP PH TOTAL N PHO%-TOT CYANIDE CADMIUM CHROMIUM COPPER LIMIT NOL 9.0 6.0 NOL NOL NOL NOL NGL 93/06 23.09 7.5-6.1 21.800 2.2000 .00OO .0000 .0000 .00OO 93/07 25.52 7.3-6.7 19.500 2.2000 .0000 .0000 .0000 37.0008 93/08 26.00 7.3-7.1 i0.iOO 2.3000 .0000 .0000 .0800 .O00O 93/09 24.85 7.7-7.i 16.300 2.3000 .0000 .0000 .0800 55.0000 9300 21.23 8.i-7.5 13.300 2.4000 .00OO .0000 .0000 28.0000 LIMIT NOL 9.0 6.0 NOL NOL NOL NOL NOL 93/ii 19.05 8.0-7.2 15.500 2.3000 .0000 .0000 .0000 28.5000 93/i2 16.35 7.7-6.8 14.000 2.8000 .0000 .0000 .00OO 33.5000 94/01 14.90 7.8-7.1 11.200 2.8000 .0000 .00OO .0000 .0OOO 94/02 14.10 7.8-73 13.900 2.5000 .0000 .00OO .00OO .00OO 94/03 15.52 7.6-7.0 13.500 1.9000 .00OO .0000 .0000 .0000 LIMIT NOL 9.0 6.0 NOL NOL NOL NOL NOL 94/04 18.60 7.9-7.2 i8.900 1.8000 .0000 .0000 .0000 iO.5000 94/05 19.76 8.0-7.4 17.500 2.5000 .00OO .0000 .00OO .000O AVERAGE 19.91 ______ 15.458 2.3333 .0000 .0080 .0000 16.006 MAXIMUM 8.i0O 21.800 2.8000 ________ ________ ........ 110.0000 MINIMUM ii.00 WOO iO.iOO i.8000 ________ ________ -------- iO.0000 UNIT DEG.0 %U MG/L UG/L UG/L UG/L UG/L . . . . . tKEi88/MF, . . 07/01/94 COMPLIANCE EVALUATION ANALYSIS REPORT PAGE 3 PERMIT--NCO037508 PIPE--001 REPORT PERIOD: 9306-9405 LOC--- E FACILITY--MOORE COUNTY WWTP DESIGN FLOW-- 6.7000 CLASS --A LOCATION--CARTHAGE REGION/COUNTY--06 MOORE 0051 0067 0077 0092 0ii47 7i9OO MONTH LEAD NICKEL SILVER ZINC SELENIUM MERCURY LIMIT NOL NOL NOL NOL NOL 93/06 .O0O0 .0800 4.0000 68.0000 .00OO .0000 93/07 .0000 .0000 .0080 40.0000 .0000 .00OO 93/08 .0000 .0000 .0000 54.0000 .0000 .00OO 93/09 .0000 .0000 .0000 .0000 .0000 .0000 93/iO .00OO .0000 .0000 38.0000 .00OO .00OO LIMIT NOL NOL NOL NOL NOL 93/ii .00OO .00OO .0000 0.5000 .00OO .00OO 9302 .0000 .8000 .00OO 87.5000 .0000 .iOOO 94/01 .8080 .00OO .0000 4i.0000 .0000 .00OO 94/02 .0000 .0000 .0000 4i.5000 .0000 .0000 94/03 .00OO 10000 .0000 40.5000 .0000 LIMIT NOL NOL NOL NOL NOL 94/04 .0000 .0000 .00OO 24.0000 .0000 .000O 94/05 .0000 .0000 5.5000 i3.5000 .8oO0 .000O AVERAGE .00OO .00OO .79i6 39.9583 .0000 .0083 MAXIMUM __- -------- ii.0000 110.0000 ........ .200O MINIMUM 12.0000 ........ -------- ________ UNIT ........ UG/L UG/L -------' UG/L UG/L UG/L UG/L State of North Carolina Department of Environment, Health, and Natural Resources Division of Environmental Management Non -Discharge Permit Application (I'H1S FORM MAYBE PHOTOCOPIED FOR USE AS AN ORIGINAL) GRAVITY SEWER EXTENSION PUMP STATIONS, AND PRESSURE S9WERS I. GENERAL INFORMATION: 1. Applicant (corporation, individual, or other): Town of Taylortown 2. Print Owners or Signing Official's Name and Title (the person who is legally responsible for the facility and its compliance): Town of Taylortown Katrina Morrison, Mayor 3. Mailing Address: 4. 4 PO Box 1274 City: Pinehurst State: NC Zip: 28374 Telephone No.: 9( 10 ) 295-4010 z, .A :.n _.1 Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans/specs., letters of flow acceptance, Operational Agreements, etc.): Utility improvements to serve Taylortown, North Carolina; CDBG No. 92-C-8239 Application Date' June 16, 1994 7. County where project is located: Moore County II. PERMIT INFORMATION: 6. Fee Submitted: $ 400.00 1. Permit No. (will be completed by DEM): WQC0f%?C-( 2. Specify whether project is: X new; renewal*; modification. *If renewal, complete only sections I through III and applicant signature (on pg.9). Submit only pgs. 1, 2, 9 (original and 3 copies of each). Engineer signature not required for renewal. 3. If this application is. being submitted as a result of a renewal or modification to an existing permit, list the existing permit number N/A and issue date 4. Specify whether the applicant is X public or private. FORM: GSPS 4/91 Page 1 of 10 GRAVITY -SEWER EXTENSION WPUMP STATION ' PAGE 2 (4/91) III. INFORMATION ON WASTEWATER: 1. Nature of Wastewater. 100 % Domestic; % Commercial; % Industrial; % Other waste (specify): 2. Please provide a one or two word description specifying the origin of the wastewater, such as school, subdivision, hospital, commercial, industrial, apartments, etc.: Subdivision and School 3. Indicate any parameter. (and its concentration) that will be greater than normal domestic levels: N/A . 4 4. If wastewater. is not domestic in nature, what level of pretreatment has been provided to ensure protection of the receiving wastewater treatment facility? N/A 5. Volume of wastewater generated by this project: 29.040 gallons per day 6. Explanation of how wastewater volume was determined: 400 students x 15 gal/day 6000 gal/day; 64 houses.x 360 gal/day = 23,040 DO IV. DESIGN INFORMATION: 1. Brief project description: 7,831 LF 8" gravity sewer, 43 manholes, 100 LF 6" Force Main, Pump Station, and Emergency Power Generator 2. Name of wastewater treatment facility receiving wastewater. Moore Water Pollution Control Facility NPDES # NCO037508 a Facility permit no.: b. Engineer should provide statement of his evaluation of downstream sewers to accept the wastewater: Village of n _h outfall is adequate and the treatment facility has adequate capacity. 2 of 10 GRAY= SEWER EXTENSION & PUMP STATION PAGE 3 (4/91) 3. Summary of sewer pipe by diameter size and pipe material. Indicate here whether C factor or N factor is used and circle C or N below: N Dia. Length Pipe C or N Min. Max. (In.) (Lin. Ft) Material Factor Slope % Slope % 8 7698 PVC 0.010 0.40 7.10 . 8 143 DIP 0.013 _0.40 5.00 Minimum Max. Minimum Velocity (fps) Vel#ps) Cover (in) 2.84 11.27 3.0 2.N 8.4t 7.0 NOTE: The minimum velocity must not be less than 2 fps. For public sewers the minimum diameter is 8 inches. 4. Anchors shall be provided for sewers with slopes greater than 20 9'0. The anchor spacing shall be as follows: ' a. 36 feet separation for slopes of 21 % to 35%; b. 24 feet separation for slopes of 36% to 50%; -c. 16 feet -separation for slopes of 50% and greater. For velocities greater than 15 fps, it is strongly recommended that measures be considered which will protect the sewers and manholes from erosion. For velocities greater than 20 fps, erosion control measures must be specified For any excessive slopes or velocities that will occur in any sewer line segment, what measures have been taken to protect the sewer pipe and manholes? N/A 5. Maximum sewer reach length between manholes: 379.49 linear feet. 6. This sewer line segment occurs between manhole no. 17 and manhole no. 18 7. Does the owner/operator have the ability to clean this length? X Yes No. 8. Sewer subject to existing or planned traffic bearing loads? Yes X No. If yes, what measures are being taken to enable the sewers to withstand the loads? 9. Outside drop manhole's are provided where invert separations exceed: feet_ 10. Identify (by manhole number) those manholes that have drop connections: #24 (S-6) 3 of 10 s GRAVITY SEWER EXTENSION & PUMP STATION ; �- PAGE 4 (4/91) 11. Maximum allowable infiltration/exfiltration test rate: 100 GPD/ pipe dia. in./ mile. Note: Must not exceed 200 GPD/ pipe dia. in./ mile. 12. Minimum separation distances as shown on the plans or addressed in the specifications: a) 100 ft. horizontal separation from wells or other water supplies? 2- Yes _ No b) 12 in. vertical separation from storm sewer or ferrous pipe sanitary sewer specified? IL Yes _No c) 10 ft. horizontal separation from water trains or 18 in. vertical separation (water over sewer) or ferrous pipe specified? X -Yes —No 13. Are manholes subject to flooding? _Yes X No 14. If yes, are manhole rim elevations 1 foot above 100-year flood level, N/A Yes _ No (100 year flood elevation should be indicated on plans) 15. Or are manholes watertight and vented 1 foot above the 100-year flood elevation (should be shown on plans): N/A Yes _ No 16. Identify (by manhole number) those manholes that are vented: N/A 17. Does this project involve any stream crossings? _ yes X_ no. If yes, what precautions or special features have been utilized to ensure protection of the sewer line and not restrict stream flow? Identify the sheet of the plans and station number where stream crossings are located: N/A 4 of 10 GRAVITY SEWER EXCTENSION & PUMP STATION PAGE 5 of 10 (4/91) V. PUMP STATION INFORMATION 1. Pump Station No.: 1 (A separate sheet VA through V.15 should be submitted for each pump station) 2. Name of closest downslope surface waters: Joe's Fork Tributary to Nick's Creek 3. Classification of closest downslope surface waters: (as established by the Environmental Management Commission & specified on page 6 of this applic.). 4. If a power failure at this pump station could impact waters classified as W$, SA, B. or SB, describe which of the measures are being implemented to prevent such impact, as required in 15A NCAC 2H .0200- Although the stream is classif ied waters, an emergency generator is avallble. 5. What size pumps are provided? 6. How many pumps are provided? 230 t GPM 7. What is the maximum capacity of the pump station? 662,400 GPD 8. What is the design total dynamic head? 114 feet . 9. How many pumping cycles will occur at the design flow rate? 6 cycles per hour 10. Check if provided at pump station: X Alternate Power Source Wet Well Vented with Screen X Fillets in Wet Well X Check Valves arid -Gate Valves X Security Fencing X Lockable Wet Well Cover X Area Light X 110V Electrical Convenience Outlet X Flood/Buoyancy Protection X High Water Alarm x Audible and Visual Auto Dialer 11. Summary of force main (by diameter size and pipe material): Diameter Length Pipe High - Low M ninmm Maximum Mmimum (Inches) (Linear Ft) Material Elevation Elevation Velodty(fps) Vel.(fps) Cover (m) 6 5980 PVC 390 312 213 4.25 3.0 12. Are air release valves provided at all high points along the force main (must be provided where the elevation difference exceeds 10 feet)? X yes _ no 13. Is pump station subject to flooding? yes X no. If yes, what measures are being taken to protect against flooding? 14. If subject to flooding, specify the 100-year flood elevation: NSA Feet MSL 15. Are there existing or planned pump stations downstream of this station? yes X no If yes, the engineer shall evaluate the ability of those pump stations to adequately handle the subject flows. GRAVITY SEWER EXTENSION & PUMP STATION PAGE 5 of 10 (4/91) V. PUMP STATION INFORMATION 1. Pump Station No.: 2 (Exist) (A separate sheet V.1 through V.15 should be submitted for each pump station) 2. Name of closest downslope surface waters: Joe's Fork Tributary to Nick's Creek 3. Classification of closest downslope surface waters: C (as established by the Environmental Management Commission & specified on page 6 of this applic.). 4. If a power failure at this pump station could impact waters classified as WS, SA, B. or SB, describe which of the measures ark bthin implemented to prevent such impact, as required in 15A NCAC 2H .0200: Alto gh the stream is classified as "C' waters, an emergency generatror is existing at this pump station. 5. What size pumps are provided? 185 GPM 2 6. How many pumps are provided? 7. What is the amaxianum capacity of the pump station? 532,800 GPD 8. What is the design total dynamic head? 58 feet . 9. How many pumping cycles will occur at the design flow rate? 6 cycles per hour 10. Check if provided at pump station: Alternate Power Source X Wet Well Vented with Screen Fillets in Wet Well Check Valves and Gate Valves X Security Fencing X Lockable Wet Well Cover X Area Light X 110V Electrical Convenience Outlet X Flood/Buoyancy ProtectionX X High Water Alarm Audible and Visual Auto Dialer 11. Summary of force main (by diameter size and pipe material): Diameter Length Pipe High Low Minimum Maximum Minimum (Inches) (Linear Ft) Material Elevation Elevation Velocity(fps) Vel.(fps) Cover (m) 6 3380 PVC 356.20 318.00 213 4.25 3.0 12. Are air release valves provided at all high points along the force :Hain (must be provided where the elevation difference exceeds 10 feet)? X yes —no 13. Is pump station subject to flooding? yes X no. If yes, what measures are being taken to protect against flooding? __R%A 14. If subject to flooding, specify the 100-year flood elevation: NSA Feet MSL 15. Are there existing or planned pump stations downstream of this station? . yes ._. no If yes, the engineer shall evaluate the ability of those pump stations to adequately handle the subject flows. All downstream pump stations are adequate to handle this additional flow. GRAVITY SEWER EXTENSION & PUMP STATION • ' ; ; PAGE 6 (4/91) R � j�ii TO: REGIONAL WATER QUALITY SUPERVISOR �Asg e provide me with the classification of the surface waters identified in number 5 dttached map segment: Joe's For Name of surface waters: k f Little R� v t r (L. w e v L; } E/� R vc v Classification (as established by the Environmental Management Commission): WS -M ROW Proposed Classification, if applicable: /VIA Signature of regional office personnel: ��-- Date: INSTRUCTIONS TO ENGINEER In order to determine whether provisions for dual or standby power may be required for the subject facility, the classification of the closest downslope surface waters (the surface waters that any overflow from the facility would flow toward) must be determined. You are required to submit this form, with items 1 through 10 completed, to the appropriate Division of Environmental* Management Regional Water Quality Supervisor (see attached listing). At a minimum, you must include an 8.5" by 11" copy of the portion of a 7.5 minute USGS Topographic Map which shows the subject surface waters. You must identify the location of the facility and the closest downslope. surface waters (waters for which you are requesting the classification) on the submitted map copy. The application may not be submitted until this form is completed and included with the submittal. 1. Applicant (corporation, individual, or other): Town of Taylortown 2. Name and Complete Address of Engineering Firm: Hobbs. Upchurch and Associates, P.A., PO Box 1737 City: Southern Pines State: NC Zip: 28388 Telephone No. (910) 692-5616 3. Project Name: Utility Improvements to Serve Taylortown, NC 4. Pump station design flow: 230 GPD; 114 GPM 5. Name of closest downslope surface waters: Joe's Fork 6. County(s) where project and surface waters are located: Moore 7. Map name and date: USGS Southern Pines Quadrangle 8. North Carolina Professional Engineer's Registration No. 17651 Bill Lester, Jr., P.E. 9. Print Name of Engineer 10. Seal and Signature (specify date): .,`'o��H•CARO( �• .• ti 9 " 17651 ' • • F/jr q� ,'•• r L ESi��' •�`'' • t ` DIVISION OF ENVIRONMENTAL MANAGEMENT REGIONAL OFFICES (4/91) Asheville Regional WQ Super. Washington Regional WQ Super. Raleigh Regional WQ Super. 59 Woodfin Place P O Box 1507 3800 Barrett Dr.. Suite 101 Asheville, NC 28802 Washington, NC 27889 Raleigh, NC 27609 704251-6208 919/946-6481 919/733-2314 Avery Macon Beaufort Jones Chatham Nash Buncombe Madison Bertie Lenoir Durham Northampton Burl= McDowell Camden Martin Edgecombe Orange Caldwell Mitchell Chowan Pamlico Franklin Person Cherokee Polk Craven Pasquotank Granville Vance Clay Rutherford Currituck Perquimans Halifax Wake Graham Swain Dare Pitt Johnston Wz= Haywood Transylvania Gates Tyrell Lee Wilson Hmkaon Yancy Greene Washington Jackson Hertford Wayne Hyde Fayetteville Regional WQ Super. Wachovia Building, Suite 714 Fayetteville, NC 28301 919/486-1541 Anson Moore Bladen Robeson Cumberland Richmond Harnett Sampson Hoke Scotland Montgomery Winston-Salem Regional WQ Super. =5 North Point Boulevard, Suite 100 Winston-Salem. NC 27106 919/161-2351 Alarnance Rockingham Alleghany Randolph Ashe Stokes Caswell Surry Davidson Watauga Davie Wilkes Forsyth Yadkin Guilford Mooresville Regional WQ Super. 919 North Main Street Mooresville, NC 28115 704/663-1699 Mecklenburg Cabarrus Rowan Catawba Stanly Gaston Union Imdell Cleveland Lincoln 7 of 10 Wilmington Region. WQ Super. 127 Cardinal Drive Extension Wilmington; NC 28405-3845 919/395-3900 Brunswick New Hanover Carteret Onslow Columbus Ponder Duplin GRAVITY SEWER EXTENSION & PUMP STATION ' PAGE 8 (4/91) ' THIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL OF THE APPLICABLE ITEMS ARE INCLUDED WITH THE SUBMITTAL Required Items a. One original and three copies of the completed and appropriately executed application form. b. Three sets of detailed plans and specifications signed and scaled by a North Carolina Professional Engineer. The plans must include a general location map, a plan view of the sewer extension, a profile of the sewer extension,- details on the pump station, and trust show the proximity of the sewer extension to other utilities and natural features. Specifications may be omitted for delegated authorities. Each sheet of the plans and the first page of the specifications must be signed and sealed. Three copies of the existing permit if . a renewal or modification. C. Three copies of all calculations, including pump selection, friction calculations, cycle time, pump curves (including system curves applicable with one pump running, two pumps running,. three pumps running, etc.), and evaluation of downstream pump stations. These items must be submitted under the signature and seal of the North Carolina Professional Engineer. d. The appropriate permit processing fee, in accordance with ISA NCAC 2H .0205(c)(5). If the owner/authority of the wastewater treatment facility (WWTF) that will be accepting the wastewater flow from this project is different from the applicant of the project, then a letter must be provided from the owner/authority of the WWTF specifying the volume of flow that will be accepted The letter should be a recent letter and should refer to the project by the same name as that identified on the application and the plans/specifications. f. An Operational Agreement (original and two copies) must be submitted if the sewer extension will be serving single family residences, condominiums, mobile homes, or town houses and if the subject sewer extension is owned by the individual residents, a homeowners association, or a developer. 8 of 10 GRAVITY SEWER EXTENSION & PUMP STATION ` PAGE 9 (4/91) Name and Complete Address of Engineering Firm: Hobbs, Upchurch & Associates, P.A. PO Box 1737 City: Southern Pines State: NC Zip: 28388 Telephone No. (910) 692-5616 Professional Engineer's Certification: I, Bill Lester, Jr., . P. E. , attest that this application for Utility Improvements to Serve Taylortown, NC' has been reviewed by me and is accurate and complete to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. North Carolina Professional Engineer's Registration No. 17651 Print Name of Engineer Bill Lester, Jr. Seal and Signature (specify date): Applicant's Certification: I, te„ or I 17651 W 10 �i '••...NE.•. a <<�LESIO" —-SW4- q� ,attest that this application for Utility Improvements to Serve Taylortown, North Carolina Katrina Morrison, Mayor has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned as incomplete. 'Signature Date <o - TH OMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INF. ORMATIONAND MATERIALS, SHOULD BE SENT TO THE FOLLOwINGADDRESS. NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 512 NORTH SALISBURY STREET RALEIGH, NORTH CAROLINA 27626-0535 TELEPHONE NUMBER: 919/733-5083 9 of 10 I GRAVITY SEWER EXTENSION & PUMP STA-010N., PACE 10 (4/91) • ` PERMIT APPLICATION PROCESSING FEES (effective October 1,1990) CATEGORY NEW APPLICATIONS/ RENEWALS WITHOUT MODIFICATIONS MODIFICATIONS > 1,000,000 GPD Industrial $400 $300 Domestic/Cooling Water $400 $300 10,001 - 1,000,000 GPD Industrial $400 $250 Domestic/Cooling Water $400 $250 1,001-10,000 GPD Industrial $400 $200 Domestic/Cooling Water $400 $200 < or = 1,000 GPD and Single Family Dwelling $240 $120 Sludge < or = 300 Acres $400 $250 Sludge > 300 Acres $400 $250 Sewer Extensions (nondelegated) $400 0 Sewer Extensions (delegated) $200 0 Closed --Loop Recycle or Evaporative $400 $200 NOTE: The Fees for Soil Remediation Projects are the same as for Sludges. Under the Sewer Extension Fee, "delegated to municipalities" applies only to those governmental jurisdictions that have specific delegation review authority, as granted by the Division of Environmental Management. 10 of 10 moo,ZF- "Wat£z &���EZ �ut�o�cty OFFICE OF SYSTEM SUPERINTENDENT July 27, 1994 Water Pollution Control System P. O. Box 813 Pinebluff, North Carolina 28373 TELEPHONE. 910-281-3146 FAX:910-281-2047 198 /( �•C°uol JUL ' 28 1994 Ms. Carolyn McCaskill, Supervisor EWy, MANAGEMENT State Engineering Review Group FAYETTEVILLE RE N.C. Dept. of Environmental Health & Natural Resources G'�FF1 Division of Environmental Management P.O. Box 27687 Raleigh,N.C. 27611 Re: Town of Taylortown Sanitary Sewer Improvements Request for Flow Acceptance HUA No. TT9203.P Dear Ms. McCaskill: The Moore County Water Pollution Control Facilities hereby agrees to conditionally accept up to 29,040 gallons per day of wastewater from the referenced project in accordance with request of July 27, 1994 by Hobbs,Upchurch & Associates, P.A., of Southern Pines, N.C. Upon completion of the referenced project, the applicant's engineer is to provide this office with the following items: 1. Infiltration in gallons per day. 2. Certification of completion as defined by N.C. Statutory Requirements #143-215.1; Section 2-H.0220. After Moore County has received a copy of the certification of completion, our office will provide a final acceptance statement. Sincerely, G ry Frick ystem Superintendent emb pc: Mr. Mitch Coleman, Exec. Director, Moore Water and Sewer Authority Bill Lester Jr., P.E. Hobs, Upchurch & Assoc, P.A. ✓6— Kerr T. Stevens, Dept. of EHNR, Fayetteville Mr. W. David McNeill, Jr., County Manager _f North Carolina ►.. nlent of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director The Honorable Katrina Morrison Town of Taylortown P.O. Box 1274 Pinehurst, NC 28374 Dear Mayor Morrison: Qom► UEHNFi July 14, 1994 '\ A , Jue is ENV. MANAGEMENT FAYETTEVILLE REG. OFFICE Subject: Application No. WQ0009621 Additional Information Request Town of Taylortown Utility Improvements Moore County The Permits and Engineering Unit has completed a preliminary engineering review of the subject application. The following items must be addressed before we can complete our review: Please submit a flow acceptance letter from Moore County for this additional flow to be accepted into the Moore Water Pollution Control Facility. 2.In accordance with 15A NCAC 2H .0219 (i) (2) (G) (ii), sanitary sewers must maintain a minimum separation from water lines of 10 feet laterally or 18 inches vertically (water over sewer). Please either provide notes on your plans indicating that the minimum lateral separation be maintained, or provide a profile view of the water line so that the Division may confirm that the vertical separation is maintained. Please forward 2 signed and sealed copies of the revised page to my attention. The questioned area is between MH#17 and MH#19 on sheet 5 of 21. Refer to the subject permit application number when providing the requested information. Please submit two (2) copies of all information to my attention at the address below. Also, please note that failure to provide this additional information on or before August 12, 1994 will subject your application to being returned as incomplete, in accordance with 15A NCAC 2H .0208. If you have any questions on this matter, please call me at (919) 733-5083 ext. 544. Sincerely, Randy L. Kepler Environmental Engineer State Engineering Review Group cc: Fayetteville Regional Office, Water Quality Hobbs, Upchurch & Associates, P.A. Permit File WQ0009621 P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-2496 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper