Loading...
HomeMy WebLinkAboutWQ0032548_Compliance Evaluation Inspection_20200219 (2)Compliance Inspection Report Permit: WQ0032548 SOC: County: Union Region: Mooresville Contact Person: John R Bass Effective: 06/29/17 Expiration: 05/31/22 owner: John R Bass Effective: Expiration: Facility: 8528 Waxhaw Creek Rd. SFR 8528 Waxhaw Creek Rd Title: Waxhaw NC 28173 Phone: Directions to Facility: From exit 61 on 1-485 travel south on Hwy 521 approx. 20 miles, continue past the intersection with SC Hwy 5, turn left onto E N Corner Rd, turn left onto Tirzah Church Rd, turn left onto Waxhaw Creek Road, turn left at unpaved drive #8528 go 0.5 miles. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 01/27/2020 Entry Time: 02:07PM Primary Inspector: Maria Schutte Secondary Inspector(s): Exit Time: 03:28PM Reason for Inspection: Routine Inspection Type: Permit Inspection Type: Single -Family Residence Wastewater Irrigation Facility Status: Compliant ❑ Not Compliant Question Areas: Miscellaneous Questions Permit Status Sand Filter/Treatment Pods Disinfection UV Drip or Irrigation General (See attachment summary) Phone: 704-663-1699 Compliance Evaluation Septic Tank Pump Tank Page 1 of 5 Permit: WQ0032548 Owner - Facility: John R Bass Inspection Date: 01/27/2020 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: Staff of the Mooresville Regional Office (MRO) conducted a compliance inspection on January 27th, 2020. The MRO would like to thank Mrs. Bass and Mr. Sid Gaskins (system contractor) for their time during the inspection. Based on the site visit and the January 29th, 2020 email communication received from Mr. Gaskins, necessary repairs and routine maintenance items were completed. The following items of interest are noted: • Per our phone conversation today, your home is sold and you are moving; but, your current contact information (email and phone) is valid for the remainder of this year. A hardcopy of this report will also be mailed to the current resident. The Change of Ownership, Renewal Application and Operations and Maintenance Agreement Forms are attached to this email for permit transition to the new owners. For future reference the forms may also be located at the NCDEQ website below. https://deq.nc.gov/about/divisions/water-resources/water-resources-permits/wastewater-branch/non-discharge-permitting-unit /application#application-forms. Scroll the page to the "Single -Family Residence Wastewater Irrigation Systems" section. • This system has historically shown significant organic material at the filter and growth of biomass throughout the system (vs. occupancy of two adults for the past several years). Mr. Gaskins cleaned all filters during the site visit. The main filter may require more frequent cleaning than is currently scheduled with the system contractor. Your contractor can advise or train you on filter cleaning between visits. Please contact Maria Schutte by email maria.schutte@ncdenr.gov or phone (704-235-2184) should you have questions. Page 2 of 5 Permit: WQ0032548 Owner - Facility: John R Bass Inspection Date: 01/27/2020 Inspection Type : Compliance Evaluation Reason for Visit: Routine Permit Status Yes No NA NE # Is the current resident in the home the Permittee? ❑ ❑ ❑ # If not, does the resident rent from the Permittee? ❑ ❑ ❑ Change of Ownership form needed? (Mail the form with the inspection letter) ❑ ❑ ❑ # Is there an inspection and maintenance agreement with a contractor? ❑ ❑ ❑ If YES, who is the contractor (include contact info)? Sid Gaskins is the system contractor (828-244-1057 or sid@watermanagementnc.net). Comment: Home is for sale. Change of Ownership, Renewal Application and Owner O&M agreement forms will be emailed with this report for the next owner. Septic Tank Yes No NA NE *** The septic tank and filters should be checked annually and pumped/cleaned as needed. Is all wastewater from the home connected to the septic tank? ❑ ❑ ❑ # Does the permittee/resident know where the septic tank is located? ❑ ❑ ❑ Has the septic tank been pumped in the last 5 years? ❑ ❑ ❑ If YES, describe if known and proof (include date pumped): Current owners have only been in the home for a couple of years. Contractor measured levels at 2 inches for bottom solids and surface scum. # Does the septic tank have an EFFLUENT FILTER or SANITARY T? 0 ❑ ❑ ❑ If FILTER, when was the filter cleaned and by who? Today by contractor. Comment: See comments in summary and cover letter. Sand Filter/Treatment Pods Yes No NA NE *** Accessible sand filter surfaces shall be raked/leveled every 6 months and vegetative growth shall be removed manually. *** # Is system something other than a sand filter? 0 ❑ ❑ ❑ # If YES, what kind? (examples - Peat, Textile or brand name - Advantex, etc.) Advantex (hanging current style) # Does the permittee know where the sandfilter is located? 0 ❑ ❑ ❑ Does the sandfilter require maintenance? ❑ ❑ ❑ If maintenace is required, explain: During previous inspections biomass bridging was seen at this unit, but looked good at the time of this inspection. Comment: See comments in summary and cover letter about manaqing oraganics caught at the filter. Disinfection UV Yes No NA NE *** UV unit shall be checked weekly. Lamps/sleeves should be cleaned/replaced as needed to ensure proper disinfection. *** Is UV working? 0 ❑ ❑ ❑ Has the UV Unit been serviced and bulbs cleaned? 0 ❑ ❑ ❑ Page 3 of 5 Permit: WQ0032548 Owner - Facility: John R Bass Inspection Date: 01/27/2020 Inspection Type : Compliance Evaluation # Who completes the weekly check for the UV? ( Non -Discharge) Reason for Visit: Routine Owner Comment: The only safe way to check UV on this system design, is to feel the control box for warmth/vibration, per discussion with the contractor. Mr. Bass travels often, but attempts to view the system weekly and maintains a notepad. Per our 2-19-2020 phone conversation, his notepad is packed as the home sold and they are moving. Pump Tank Yes No NA NE *** All pump and alarm sytems shall be inspected monthly. (Non -Discharge) Is the pump working? 0 ❑ ❑ ❑ Is the audible and visual high water alarm operational? 0 ❑ ❑ ❑ # Does the permittee know how to check the pump & high water alarm? ❑ ❑ ❑ # Last functional test: During site visit. Comment: The float is on delay to contact Mr. Gaskins, so it will not trigger the alarm system (in a timely manner) while on -site. The contractor triggered the alarm at the panel. Both audible and visual were operational at the time of inspection. The visual is rather dim and angled in a manner that seems it would be difficult to see at the home. But, that is how the system was designed/installed. Drip or Irrigation Yes No NA NE *** Irrigation sysetm shall be inspected monthly to ensure system is free of leaks and equipment is operating as designed. *** # Type of system (DRIP or IRRIGATION): Drip # If IRRIGATION, number of sprinkler heads: NA Are buffers and setbacks adequate? ❑ 0 ❑ ❑ Is the site free of ponding and runoff? ❑0 ❑ ❑ Does the application equipment appear to be working properly? ❑ ❑ ❑ Is there a minimum two wire fence surrounding the entire irrigation area? 0 ❑ ❑ ❑ Comment: There is a waiver with this system, because the drip lines encroach on the fifty -foot setback from the access road leading to a neighbor's property. The waiver was signed and filed with Union County Register of Deeds when the current owners acquired this permit. It was raining during this site visit. There was minimal ponding at a small portion of the drip field near a pate. The drip field (and a sloped piece of land in the back corner) is the driest area throughout this property. The surrounding grounds were saturated. General Yes No NA NE # Are the treatment units locked and/or secured? 0 ❑ ❑ ❑ # Has resident had any sewage problems? ❑ 0 ❑ ❑ If YES, explain: The resident has not contacted their contractor with any sewage concerns. Does the system match the permit description? ❑ ❑ ❑ If NO, explain: Is the system compliant? ❑ ❑ ❑ Page 4 of 5 Permit: WQ0032548 Owner - Facility: John R Bass Inspection Date: 01/27/2020 Inspection Type : Compliance Evaluation Is the system failing? (If yes, take pictures if possible) If system is failing, describe any exposures to people/animals or environmental risks. Increased frequency of filter washing is suggested. See summary and cover letter. Reason for Visit: Routine ❑■❑❑ Comment: MRO staff anticipates visiting this property for a technical assistance inspection, upon receipt of the new owner application. Page 5 of 5