Loading...
HomeMy WebLinkAboutWQ0016218_Permit (Issuance)_19990811State'of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary Kerr T Stevens, Director Dale Burris Stanley Memorial Hospital 301 Yadkin Street Albemarble, North Carolina 28001 Dear Mr. Burris: 'L . . _J AUG I L 099 DW Q --_ August 11, 1999 4 0 • 17 NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Subject: Permit No. WQ0016218 Stanley Memorial Hospital Troy Medical Office Building Wastewater Collection System Montgomery County In accordance with your application received June 11, 1999 we are forwarding herewith Permit No. WQ0016218 dated August 11, 1999, to Stanley Memorial Hospital for the construction and operation of the subject wastewater collection extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding. One set of approved plans and specifications is being forwarded to you. If you need additional information concerning this matter, please contact Ron Palumbo at (919) 73 083 extension 533. Sincere .Kerr T. Stevens cc: Montgomery County Health Department Fayetteville Regional Office, Water Quality Section Burton Engineering Associates 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone (919) 733-5083 Fax (919) 715-6048 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Stanley Memorial Hospital/Troy Medical Building Montgomery County FOR THE construction and operation of a 20 GPM pump station with duplex pumps, on -site audible and visual high water alarms, portable generator connector, portable generator and approximately 1,035 linear feet of 2-inch force main to serve the Troy Medical Office Building, and the discharge of 800 GPD of collected domestic wastewater into the Town of Troy's existing sewerage system, pursuant to the application received June 11, 1999, and in conformity with the project plan, specifications, and other supporting data subsequently filed and approved by the Department of Environment and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The facilities must be properly maintained and operated at all times. 4. The sewage and wastewater collected by this system shall be treated in the Town ofTroy's Wastewater Treatment Facility (NC0028916) prior to being discharged into the receiving stream. 5. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality (Division) accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 6. Construction of the sewers, pump station(s) and force main shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 7. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting materials. If this project is to be completed in phases and partially certified, you shall retain the responsibility to track further construction approved under the same permit, and shall provide a final certificate of completion once the entire project has been completed. Mail the Certification to the Non -Discharge Permitting Unit, P.O. Box 29535, Raleigh, NC 27626-0535. 8. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of five years from the date of the completion of construction. 9. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 10. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 11. The Permittee shall provide for the pump station and force main the following items: a. Pump on/off elevations located so that 2-8 pumping cycles may be achieved per hour in the pump station, b. An air relief valve located at all high points along the force main, c. A screened vent for the wet well, d. Fillets located in the wet well at the intersection of the flooring and sidewalls, e. Three feet of cover (minimum) over the force main or the use of ferrous material where three feet cannot be maintained, f. Sufficient devices which will protect the pump station from vandals, and g. Flood protection if the pump station is located below the 100-year flood elevation. 12. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement wastewater collection facilities. 13. NONCOMPLIANCE NOTIFICATION: The Permittee shall report by telephone to the Fayetteville Regional Office, telephone number (919) 486-1541, as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. 2 Persons reporting such occurrences by telephone shall also file a written report in letter form within five (5) days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. 14. This permit shall become voidable unless the agreement between Stanley Memorial Hospital/Troy Medical Office Building and the Town of Troy for the collection and final treatment of wastewater is in full force and effect. Permit issued eleventh day of August, 1999 AL MANAGEMENT COMMISSION ;,,Kerr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission Permit Number WQ0016218 Permit No. WQ0016218 August 11, 1999 ENGINEER'S CERTIFICATION Partial Final I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, Project Name Location and County for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of this permit, the approved plans and specifications, and other supporting materials. Signature Date Registration No. MEMO TO: State Review Group Division of Water Quality FROM: Ricky Revels ho-"� Fayetteville Regional Office SUBJECT: Procedure Four (4) June 25. 1999 WQ0016218 Date Troy Medical Office Building Sewer Extension - Private Stanly Memorial Hospital - Owner Montgomery County State Review Group Review Engineer Ron Palumbo Regional Office Contact &14Revels 1) Name of wastewater treatment plant to receive the wastewater: Town of Troy WWTP 2) WWTP design capacity 0,8400 MGD 3) NPDES Permit No. NC0028916 Expiration Date: 06/30/1999 4) Compliance Information: Present treatment plant performance for previous _12 months, beginning 1/98 - 12/98 (See attached self -monitoring data) 5) Quantity and type of wastewater from proposed sewers: 2,000 GPD domestic X_ industrial other 6) Volume from previously approved projects not yet tributary to WWTP: -4,500- GPD 7) Regional Recommendations: Approval _X_ Denial R/rr Enclosure