Loading...
HomeMy WebLinkAboutNCS000532_Wright Chemical Monofill 2020 Top Water Analysis Results_20200330leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 March 27, 2020 Bill Oakley Oak -Bark Corporation 2214 E Wrightsville Ave Wilmington, NC 28403 RE: Project: Water Analysis Pace Project No.: 92470703 Dear Bill Oakley: Enclosed are the analytical results for sample(s) received by the laboratory on March 24, 2020. The results relate only to the samples included in this report. Results reported herein conform to the most current, applicable TNI/NELAC standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. Some analyses have been subcontracted outside of the Pace Network. The subcontracted laboratory report has been attached. If you have any questions concerning this report, please feel free to contact me. Sincerely, Amanda Payne amanda.payne@pacelabs.com (704)875-9092 Project Manager Enclosures cc: One Time Client REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 1 of 22 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: Water Analysis Pace Project No.: 92470703 Pace Analytical Services Asheville 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 Massachusetts Certification #: M-NC030 North Carolina Drinking Water Certification #: 37712 CERTIFICATIONS North Carolina Wastewater Certification #: 40 South Carolina Certification #: 99030001 Virginia/VELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 2 of 22 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 SAMPLE SUMMARY Project: Water Analysis Pace Project No.: 92470703 Lab ID Sample ID Matrix Date Collected Date Received 92470703001 Water Analysis A-1 Water 03/23/20 11:51 03/24/20 10:10 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 3 of 22 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 SAMPLE ANALYTE COUNT Project: Pace Project No.: Water Analysis 92470703 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92470703001 Water Analysis A-1 EPA 200.7 Rev 4.4 1994 RDT 4 PASI-A EPA 9040C ECH 1 PASI-A EPA 300.0 Rev 2.1 1993 CDC 4 PASI-A EPA 350.1 Rev 2.0 1993 KDF1 1 PASI-A SM 5310B-2011 ECH 1 PASI-A REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 4 of 22 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: Water Analysis Pace Project No.: 92470703 Sample: Water Analysis A-1 Parameters Lab ID: 92470703001 Collected: Report Results Units Limit 03/23/20 11:51 MDL DF Received: 03/24/20 10:10 Matrix: Water Prepared Analyzed CAS No. Qual 200.7 MET ICP Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994 Copper ND ug/L 5.0 2.1 1 03/27/20 00:56 03/27/20 13:58 7440-50-8 Iron 121 ug/L 50.0 19.5 1 03/27/20 00:56 03/27/20 13:58 7439-89-6 Manganese 34.9 ug/L 5.0 0.90 1 03/27/20 00:56 03/27/20 13:58 7439-96-5 Zinc 6.2J ug/L 10.0 3.9 1 03/27/20 00:56 03/27/20 13:58 7440-66-6 9040 pH Analytical Method: EPA 9040C pH at 25 Degrees C 7.5 Std. Units 0.10 0.10 1 03/27/20 12:00 H3 300.0 IC anions 48hr Analytical Method: EPA 300.0 Rev 2.1 1993 Nitrate as N 0.45 mg/L 0.10 0.060 1 03/24/20 19:08 14797-55-8 Nitrate -Nitrite (as N) 0.45 mg/L 0.20 0.11 1 03/24/20 19:08 7727-37-9 Nitrite as N ND mg/L 0.10 0.050 1 03/24/20 19:08 14797-65-0 Sulfate 4.0 mg/L 1.0 0.50 1 03/24/20 19:08 14808-79-8 350.1 Ammonia Analytical Method: EPA 350.1 Rev 2.0 1993 Nitrogen, Ammonia 4.4 mg/L 0.10 0.070 1 03/26/20 13:56 7664-41-7 531013 TOC Analytical Method: SM 531 OB-2011 Total Organic Carbon 16.6 mg/L 1.0 0.50 1 03/26/20 23:42 7440-44-0 Date: 03/27/2020 03:46 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 5 of 22 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Water Analysis Pace Project No.: 92470703 QC Batch: 532848 Analysis Method: EPA 200.7 Rev 4.4 1994 QC Batch Method: EPA 200.7 Rev 4.4 1994 Analysis Description: 200.7 MET Associated Lab Samples: 92470703001 METHOD BLANK: 2844221 Matrix: Water Associated Lab Samples: 92470703001 Blank Reporting Parameter Units Result Limit MDL Analyzed Qualifiers Copper ug/L ND 5.0 2.1 03/27/2013:52 Iron ug/L ND 50.0 19.5 03/27/2013:52 Manganese ug/L ND 5.0 0.90 03/27/2013:52 Zinc ug/L ND 10.0 3.9 03/27/2013:52 LABORATORY CONTROL SAMPLE: 2844222 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Copper ug/L 500 500 100 85-115 Iron ug/L 5000 4850 97 85-115 Manganese ug/L 500 487 97 85-115 Zinc ug/L 500 494 99 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2844223 2844224 MS MSD 92470703001 Spike Spike MS MSD MS MSD % Rec Max Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD RPD Qual Copper ug/L ND 500 500 552 540 110 108 70-130 2 20 Iron ug/L 121 5000 5000 5200 5190 102 101 70-130 0 20 Manganese ug/L 34.9 500 500 558 544 105 102 70-130 3 20 Zinc ug/L 6.2J 500 500 545 532 108 105 70-130 2 20 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 03/27/2020 03:46 PM without the written consent of Pace Analytical Services, LLC. Page 6 of 22 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Water Analysis Pace Project No.: 92470703 QC Batch: 532958 Analysis Method: EPA 9040C QC Batch Method: EPA 9040C Analysis Description: 9040 pH Associated Lab Samples: 92470703001 SAMPLE DUPLICATE: 2844596 92470703001 Dup Max Parameter Units Result Result RPD RPD Qualifiers pH at 25 Degrees C Std. Units 7.5 7.6 1 9 H3 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 03/27/2020 03:46 PM without the written consent of Pace Analytical Services, LLC. Page 7 of 22 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Water Analysis Pace Project No.: 92470703 QC Batch: 532211 Analysis Method: EPA 300.0 Rev 2.1 1993 QC Batch Method: EPA 300.0 Rev 2.1 1993 Analysis Description: 300.0 IC Anions Associated Lab Samples: 92470703001 METHOD BLANK: 2841099 Matrix: Water Associated Lab Samples: 92470703001 Blank Reporting Parameter Units Result Limit MDL Analyzed Qualifiers Nitrate as N mg/L ND 0.10 0.060 03/24/20 18:40 Nitrate -Nitrite (as N) mg/L ND 0.20 0.11 03/24/20 18:40 Nitrite as N mg/L ND 0.10 0.050 03/24/20 18:40 Sulfate mg/L ND 1.0 0.50 03/24/20 18:40 LABORATORY CONTROL SAMPLE: 2841100 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Nitrate as N mg/L 2.5 2.4 95 90-110 Nitrate -Nitrite (as N) mg/L 5 4.8 96 90-110 Nitrite as N mg/L 2.5 2.5 98 90-110 Sulfate mg/L 50 49.3 99 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2841101 2841102 MS MSD 92470703001 Spike Spike MS MSD MS MSD % Rec Max Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD RPD Qual Nitrate as N mg/L 0.45 2.5 2.5 3.0 3.0 102 103 90-110 1 10 Nitrate -Nitrite (as N) mg/L 0.45 5 5 5.4 5.5 100 102 90-110 2 10 Nitrite as N mg/L ND 2.5 2.5 2.5 2.5 97 100 90-110 2 10 Sulfate mg/L 4.0 50 50 53.5 53.6 99 99 90-110 0 10 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 03/27/2020 03:46 PM without the written consent of Pace Analytical Services, LLC. Page 8 of 22 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Water Analysis Pace Project No.: 92470703 QC Batch: 532598 Analysis Method: EPA 350.1 Rev 2.0 1993 QC Batch Method: EPA 350.1 Rev 2.0 1993 Analysis Description: 350.1 Ammonia Associated Lab Samples: 92470703001 METHOD BLANK: 2843055 Matrix: Water Associated Lab Samples: 92470703001 Blank Reporting Parameter Units Result Limit MDL Analyzed Qualifiers Nitrogen, Ammonia mg/L ND 0.10 0.070 03/26/20 13:31 LABORATORY CONTROL SAMPLE: 2843056 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Nitrogen, Ammonia mg/L 5 5.0 101 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2843057 2843058 MS MSD 92470480002 Spike Spike MS MSD MS MSD % Rec Max Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD RPD Qual Nitrogen, Ammonia mg/L ND 5 5 4.8 4.8 96 96 90-110 0 10 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2843059 2843060 MS MSD 92470480003 Spike Spike MS MSD MS MSD % Rec Max Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD RPD Qual Nitrogen, Ammonia mg/L 0.30 5 5 5.2 5.1 97 97 90-110 0 10 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 03/27/2020 03:46 PM without the written consent of Pace Analytical Services, LLC. Page 9 of 22 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Water Analysis Pace Project No.: 92470703 QC Batch: 532818 Analysis Method: SM 531 OB-2011 QC Batch Method: SM 531 OB-2011 Analysis Description: 5310E TOC Associated Lab Samples: 92470703001 METHOD BLANK: 2844043 Matrix: Water Associated Lab Samples: 92470703001 Blank Reporting Parameter Units Result Limit MDL Analyzed Qualifiers Total Organic Carbon mg/L ND 1.0 0.50 03/26/20 19:35 LABORATORY CONTROL SAMPLE: 2844044 Spike LCS LCS % Rec Parameter Units Conc. Result % Rec Limits Qualifiers Total Organic Carbon mg/L 25 23.6 94 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2844045 2844046 MS MSD 92469500001 Spike Spike MS MSD MS MSD % Rec Max Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD RPD Qual Total Organic Carbon mg/L ND 25 25 22.4 22.9 89 91 90-110 2 10 M1 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2844047 2844048 MS MSD 92470276002 Spike Spike MS MSD MS MSD % Rec Max Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD RPD Qual Total Organic Carbon mg/L 5.3 25 25 28.3 28.4 92 93 90-110 1 10 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 03/27/2020 03:46 PM without the written consent of Pace Analytical Services, LLC. Page 10 of 22 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALIFIERS Project: Water Analysis Pace Project No.: 92470703 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI -The NELAC Institute. LABORATORIES PASI-A Pace Analytical Services - Asheville ANALYTE QUALIFIERS H3 Sample was received or analysis requested beyond the recognized method holding time. M1 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 03/27/2020 03:46 PM without the written consent of Pace Analytical Services, LLC. Page 11 of 22 leAnalyiical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: Water Analysis Pace Project No.: 92470703 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 92470703001 Water Analysis A-1 EPA 200.7 Rev 4.4 1994 532848 EPA 200.7 Rev 4.4 1994 532868 92470703001 Water Analysis A-1 EPA 9040C 532958 92470703001 Water Analysis A-1 EPA 300.0 Rev 2.1 1993 532211 92470703001 Water Analysis A-1 EPA 350.1 Rev 2.0 1993 532598 92470703001 Water Analysis A-1 SM 5310E-2011 532818 Date: 03/27/2020 03:46 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 12 of 22 Document Name: Document Revised: February1, 2018 a Sample Condition Upon Recei t(SCUR) Page 1 of 2 Z r?IIIa1j lCc�I Document No.: Issuing Authority: F-CAR•CS•033-Rev.06 Pace Carolinas Quality Office Laboratory receiving sa ies: Asheville Eden[:]Greenwood ❑ Huntersville ❑ Raleigh❑ Mechanicsville❑ Sample. , `.I Client Name: WO# : 92470703 Upon ,('' Project # Courier: ZFed Ex ❑UPSrv� ❑USPS� ❑Client IN 11111111111 ❑ Commercial []Pace ❑other: 97470703 Custody Seal Present? ❑Yes FZ(No seals Intact? ❑Yes JEfNo Date/Initla_ls_Person ExaminingContenfs: 3, 21q 2 D Packing Material: ' ❑Subhle Wrap Bubble Bags ❑None ❑ Other Biological Tissue Frozen? Thermomete : Oyes ❑No ,K/A ` Type o! Ice: 2fwet ❑Blue ❑None �IR Gun ID: Cooler Temp (°t): Correction Factor: Add/subtract ('C} Qr Temp should he above freezing to 6°C Cooler Temp Corrected C): r []Simples out of temp criteria. Samples an Ice, cooling process has begun USDA Regulated Soil N/A, water sample} Did samples originate In a quarantine zone within the United States: CAA, NY, or SC (check maps)? Did samples originate from a foreign source (internationally, r7L,-. 171— Including Hawaii and Puerto RICO)? []Yes [:]No Chain of Custody Present? Samples Arrived within Hold Time? Short Hotd Time Analysis (c32 hr.)? Rush Turn Around Time Requested? Sufficient Volume? Correct Containers Used? -Pace Containers Used? Contalners Intact? Dissolved analysis; Samples Field Flltered? -Includes Date/Time/iD/Analysis Headspace in VOA Vials (>5-6mm)? Trip Blank Present? Trip Blank Custody Seals Present? No ❑N/A 1. No ❑N A No N/A 3. No MIA 4. ❑No QN/A I &. Yes _[:]No ❑N/A 7• []Y sC24 N/A 8. 10 []Yes L` N q9e /A la. []Yes a N/A 11. COMMENTS/SAMPLE DISCREPANCY Field Data Requlred? ❑Yes j�J0 A—� T AI 5dw. Oc r CLIENT NOTIFICATION/RESOLUTION Person contacted: Project Manager SCURF Review: Project Manager SRF Review: Lot ID of split containers; pat2/TiFne� Date: Date: Page 13 of 22 Document Name: 1 Document Revised: February 7, 2018 fi c?C8Ai1c?Ij/�'Cc?f Sample Condition U an Recerpt{SOUR} Page 1 of 2 Document No.: Issuing Authority: F-CAR-CS-033•Rev.06 Pace Carolinas Quality Office *Check mark top half of box If pH and/or dechlorinstlon Is Project # verified and within the acceptance range for preservation jO ���O�O� samples, w 9 Exceptions: VCA, Coliform, TOC, Oil and Grease, DRO/8015 (water) DOC, LLHg PM: NMG Due Date: 04/02/20 "Bottom half of box is to list number of bottle CLIENT: 92—ONE TIME P.e v c c u a a t" E r� m 'L G U a S g U m a a in o S E ry m a O z = a a m z- m a N U d CL £ m a O= z u a E `ri m a fO S r7 .c a E v_ Z 2 a 7 E ` .a 4 y ° 2 E 'S t d c L N J o `�` d a Z l7 d a O N = £ J E z A 5 Q .-I h N m z A E t9 o 0 y ry m a O y z 6 a J f a ? 4 KI O E n ^�^ o �;' +, � O 7 2 a d Q 9 � m d N E p 4 a J E Ln Di13 _ m N y 2 - E n a m > n c w c o 3>> l7 4 N y c $ p C E 0 z a J E 0� co t7 1 \LNN\ 1 \N x 3 4 5 8 7 8 1Q li 12 N= I N pH Adjustment Log for Preserved Samples Sample ID Type of Preservative pH upon receipt date preservatlon'adjusted Time preservation Amount of Preservative Lot h added Note: Wheneverthere is a discrepancy affecting North Carolina compliance samples, a copy ofthls form will hesentto the North Carollna EEHNRCertlfication Office Il,e. Out of hold, Incorrect preservative, out of temp, incorrect containers. Page 14 of 22 n m m TEMP in 0 Recehred on Cooler YI(-N) -- Samplas Inlacl (YIN} _. __ ... W. 3 a're Lo'3r dl�t¢ Gn. HI . sJi - ITEM# _ 3 o cn 0° ° a _ ° > Ck o a R rn 3 t v ro u .-r °aW 1 y e °a MATRiXCOBE heevdidcodes ioten) m 1 p SAMPLETYPE (G-GRAB C•COMP) s3s v a SV N N- h m h r O ` � r• VS � fi a \ ll`117 i SAMPLE TEMPAT COLLECTION !.. fir.. �+' ^ .-�. •"� �-.. Y OF CONTAINERS ro ro o "n ° �" N unpreaerved 4 a v r{ C LK H2804 HNO3 6 m a R i 3 . ^ f MCI rD m O NaOH D 1(' NO25203 N m Methanol g ROW CA` Z t#315 Formaldehyd64 �] i o Me(ols N M m NO21N031604 0 PH s .�•I TOC 1 1. i i1,5 hq t:i; a d1 1, yd Iiiiiiiii m Page 15 of 22 ANALYTICAL ENVIRONMENTAL SERVICES, INC. AES March 27, 2020 Amanda Payne Pace Analytical Services, Inc. 9800 Kincey Ave Suite 100 Huntersville NC 28078-8400 RE: 92470703 Dear Amanda Payne: Order No: 2003P43 Analytical Environmental Services, Inc. received for the analyses presented in following report. samples on 3/25/2020 9:46:00 AM No problems were encountered during the analyses. Additionally, all results for the associated Quality Control samples were within EPA and/or AES established limits. Any discrepancies associated with the analyses contained herein will be noted and submitted in the form of a project Case Narrative. AES' certifications are as follows: -NELAP/Florida State Laboratory ID E87582 for analysis of Non -Potable Water, Solid & Chemical Materials, Air & Emissions for Organics, and Drinking Water Microbiology & Metals, effective 07/01/19-06/30/20. -North Carolina Certification number 562 for analysis of Surface Water, Groundwater, Effluent, effective until 12/31/20. -South Carolina Environmental Laboratory Certification number 98016003 effective until 6/30/20. These results relate only to the items tested as received. This report may only be reproduced in full and with written permission from the laboratory. If you have any questions regarding these test results, please feel free to call. Sincerely, Jessica Shilling Project Manager 3080 Presi4ential Drive • Atlanta, Georgia 30340 -Tel: 770.457,8177 • Fax: 770.457.8188 • Toll F.,e:800.972.4889 __x .tlanta_c Page 16 of 22 Page 1 of 7 P. b • u�ul 0 W Z g 1 ,i�� �SIFN c O IN N II; d Ul "jl Z W 7"f4" wN•" a16. rMnp Q W y�. I�Er P apA4apjewao3 •i�.'_ "illl 'Li1 Illy/iYiN�' iI ��lyyyll�l �prl t E �r C Q VIA •Q AMtl� � AI iiM t�' i•�1 �'I ! �i h11 F r1 �7e' I ili;,, NI e P6N8SBJCIU("I � rE Ir. I11 I Lrrl Z\LQ� I "���nu. I11 ii i N 1 S 1� m co13 r. a �ueni.., •• B 94ppryI "I I i-.r M I I u�I1 lYlill CD O M ' I.I II 4f V} •V jg n 1II� C O I a �., ��,,'lJ'J,N IiuL'11P� A1el jRl i n •_ a �.P n'r oohs Ix O tl Ipp I I�i y +,�Ijjr! it"d �' j y'i C t °mil /1 y}, Q n? QI��gIII I• °"��in FWI it "E 1� k , II } ,, ,, j O N�au P o � i 14' I;•�a N jl�g � j� N Uirle; r�,iryG' �� �„ vi r� �' P I � I�i •� U i�'i` / , O p 9[[ j urn^I r � cr o N i 7 0 Ilr �P r^ PI f6 (n O T L �i. Nrir` 1 0 N r �� _ � �, C. � i . Nr I N".9a Z F- cO C. �Ilill N aim �. j" 0 12 i�' 9 E T " N Q N •a I �, N co 0 (a 'N r 46 D +� E c oo Sc) E ��il Lu 00 Page 17 7 Q d O= (. W U) .�. ;. c `-' N C'M V U.) N L 2 m f MZ k d Analytical Environmental Services, Inc Date: 27-Mar-20 Client: Pace Analytical Services, Inc. Client Sample ID: WATER ANALYSIS A-1 Project Name: 92470703 Collection Date: 3/23/2020 11:51:00 AM Lab ID: 2003P43-001 Matrix: Aqueous Reporting Dilution Analyses Result Qual Units BatcbID Date Analyzed Analyst Limit Factor Formaldehyde by SW8315A Formaldehyde 430 50 ug/L 294596 1 03/26/202014:11 HL Qualifiers: • Value exceeds maximum contaminant level BRL Below reporting limit H Holding times for preparation or analysis exceeded N Analyte not NELAC certified B Analyte detected in the associated method blank > Greater than Result value E Estimated (value above quantiitatiion range) S Spike Recovery outside limits due to matrix Nan' See case narrative F Analyzed in the lab which is a deviation from the method < Less than Result value J Estimated value detected below Reporting Limit Page 18 of 22 Page 3 of 7 U) m W �a Cl) U U are a,� m v v a a E E a) F v o0 v v O O V U V O u v J O v a, c0 f6 CL O. E E F i N t0 a) aJ O O 0 U 0 0 00 Y Y a a F F C Ln a) a, a E U U U ry ri V Vl 6 I, o0 Ol O s4 N m R V1 ci ci ci c-I a -I c-I vi 0 v 0 U OZf E v F a) V C C' \ Q H aJ F � n E a5 N 6 � � v s 0 ai u v s 3 o T -p Y C � c Y C L U o Q N W � a ❑ N U =p LO E O v c m U Q OCCCO O • V C f6 C L r. C O+ M sti E sn O a � o t 3 O n• ^ U LV O U OV CO ON O L 'O C m o c •cu L a C — ` mc -p a 0 C 0 v ^ -7 3 no Q v v ba > 'F U O o a O aci N U Y v o U •sn 'O vs v y a) O at0+ C 7 O C a1 iv a c N N O O O wE '6 r OV C C O O +. O E C , 7 v 7 u N of _ Y to C T 'O >, 'O � aJ }.. f` O O a1 O O s0 E 'a a o 0 � 0. E C v p. O E c m c m a E y F H t U u H U .2-. U U v1 a Q Q Z z u U O ❑ ❑ O C v C N o > O -0 v o 'aw v tio L V in 2 N - - O 0 O C O C ❑❑ C U O -0 C o > o C a Cti a -a E ti a a a a EEEE o 0 j •0® o - O 000000 •qO O • O • • • a) a) T M1• a � � C m � rv, Q/ sti v G. i N r. vs ^' U rv• O U 2 a) c c C OV R -O V C al O w 0 p a) E C C C L C O I C m C p aF s C O C Y C E O > = j O L 7 p O. V a u 0 0 al p On Q >' Y E a E E U ° M v C H C C _ O N C > i a p c v a V v a +�C+ E c c O ti o. v 'u > v N ar C 01 OV U a/ H C O C• C m 7 f0 '^ C '^ i C- Y c v a a v E c a m $ E> v m m w M a a E a T o i E 0 c m N T T N > >_ a+ a) o 0 0 v 3 v v v cu LLLU' u H 0 v Q w N 'O 0 w w w Y E U l0 r, o0 an O c4 fV M V V1 l0 I-� a -I c-I c-I c-I N N N N N N N N 0 0 Ln Ln m a m � a Q Q 0 V a) 0) N d ul m V f0 C C W C Y E m O 'O U 6 p P O N M l0 00 a -I N v7 c an c 0 0 u u 41 C aC.. w N a a E E V u a s Cs N m N CO a7 M Y � W 06 W y y O — c — m U 10 O Q) % IN E O U t V N O_ U O_ \ Z • • • U c 0 O z Q C m ' o > m `o t c N ■ ^. U m � L U aj Y a) N N L co E C al 9 9 �- C 2? C o � > m cn N m a) N C d E — 'O O U E (n 00 U C O Q c V co N v O N d m nca CL E E Q aj a v ti % aJ C ` O_ Y m >. N p, i N N c > O 16 C E 7 C 1, M ` a .q wY Ou w a c m > I H U 2 U Z cYi N WENe a) 19 of 225 Analytical Environmental Services, Inc Date: 27-Mar-20 Client: Pace Analytical Services, Inc. Project Name: 92470703 Dates Report Lab Order: 2003P43 Lab Sample ID Client Sample ID Collection Date Matrix Test Name TCLP Date Prep Date Analysis Date 2003P43-001A WATER ANALYSIS A-1 3/23/2020 11:51:OOAM Aqueous Formaldehyde by SW8315A 3/26/2020 7:50:57AM 03/26/2020 Page 20 of 22 Page 5 of 7 Analytical Environmental Services, Inc Client: Pace Analytical Services, Inc. Project Name: 92470703 Workorder: 2003P43 Date: 27-Mar-20 ANALYTICAL QC SUMMARY REPORT BatchID: 294596 Sample ID: MB-294596 Client ID: Units: ug/L Prep Date: 03/26/2020 Run No: 421736 SampleType: MBLK TestCode: Formaldehyde by SW8315A BatchID: 294596 Analysis Date: 03/26/2020 Seq No: 9540553 Analyte Result RPT Limit SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit Qual Formaldehyde BRL 50 Sample ID: LCS-294596 Client ID: Units: ug/L Prep Date: 03/26/2020 Run No: 421736 SampleType: LCS TestCode: Formaldehyde by SW8315A BatchID: 294596 Analysis Date: 03/26/2020 Seq No: 9540554 Analyte Result RPT Limit SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit Qual Formaldehyde 1013 50 1000 101 70 130 Sample ID: 2003P44-004AMS Client ID: Units: ug/L Prep Date: 03/26/2020 Run No: 421736 SampleType: MS TestCode: Formaldehyde by SW8315A BatchID: 294596 Analysis Date: 03/26/2020 Seq No: 9540556 Analyte Result RPT Limit SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit Qual Formaldehyde 996.3 50 1000 99.6 50.1 139 Sample ID: 2003P44-004AMSD Client ID: Units: ug/L Prep Date: 03/26/2020 Run No: 421736 SampleType: MSD TestCode: Formaldehyde by SW8315A BatchID: 294596 Analysis Date: 03/26/2020 Seq No: 9540557 Analyte Result RPT Limit SPK value SPK Ref Val %REC Low Limit High Limit RPD Ref Val %RPD RPD Limit Qual Formaldehyde 1062 50 1000 Qualifiers: > Greater than Result value BRL Below reporting limit J Estimated value detected below Reporting Limit Rpt Lim Reporting Limit 106 50.1 139 996.3 6.42 16.2 < Less than Result value E Estimated (value above quantitation range) N Analyte not NELAC certified S Spike Recovery outside limits due to matrix B Analyte detected in the associated method blank H Holding times for preparation or analysis exceeded R RPD outside limits due to matrix Page 21 of 22 Page 6 of 7 End of Report Page 22 of 22 Page 7 of 7