HomeMy WebLinkAbout20190749 Ver 2_Meeting Minutes_20200327
Wanucha, Dave
From:Euliss, Amy
Sent:Thursday, March 26, 2020 9:52 AM
To:Wanucha, Dave; Braspennickx, Nicholle M CIV USARMY CESAW (US)
Cc:White, Chuck; Braquet, Stephanie
Subject:RE: Brown Road pipe replacement Stokes)
Thanks Dave for the quick response! Since the temporary nor permanent impacts aren’t changing, can we send in
revised plans instead of a formal modification?
From: Wanucha, Dave <dave.wanucha@ncdenr.gov>
Sent: Thursday, March 26, 2020 9:48 AM
To: Euliss, Amy <aeuliss@ncdot.gov>; Braspennickx, Nicholle M CIV USARMY CESAW (US)
<Nicholle.M.Braspennickx@usace.army.mil>
Cc: White, Chuck <crwhite@ncdot.gov>; Braquet, Stephanie <scbraquet@ncdot.gov>
Subject: RE: Brown Road pipe replacement Stokes
I have no objections to the change; only request a formal permit modification. Let me know if you need
anything further.
Thanks.
Dave W.
Division of Water Resources
401 & Buffer Transportation Permitting
NC Department of Envirionmental Quality
336-776-9703 office
336-403-5655 mobile
Dave.Wanucha@ncdenr.gov
NC DEQ Winston Salem Regional Office
450 West Hanes Mill Road, Suite 300
Winston Salem, NC 27106
Based on the current guidance to minimize the spread of COVID-19, the Department of Environmental Quality has
adjusted operations to protect the health and safety of the staff and public. Many employees are working remotely or
are on staggered shifts. To accommodate these staffing changes, all DEQ office locations are limiting public access to
appointments only. Please check with the appropriate staff before visiting our offices, as we may be able to handle your
requests by phone or email. We appreciate your patience as we continue to serve the public during this challenging
time.
From: Euliss, Amy <aeuliss@ncdot.gov>
Sent: Thursday, March 26, 2020 8:27 AM
To: Wanucha, Dave <dave.wanucha@ncdenr.gov>; Braspennickx, Nicholle M CIV USARMY CESAW (US)
<Nicholle.M.Braspennickx@usace.army.mil>
1
Cc: White, Chuck <crwhite@ncdot.gov>; Braquet, Stephanie <scbraquet@ncdot.gov>
Subject: Brown Road pipe replacement Stokes
Dave and Nicholle,
We have written 404 and 401 permits for the replacement of 2 lines of 98”x72” CMPA with 4’ in between the pipe (Total
of 192”). We have had the road closed since flooding damages caused a pipe failure on February 6, 2020. Prior to the
failure of the pipe, the plan was to replace with a 2 barrel 8’X7’ reinforced concrete box culvert that was going to be let
to contract. However, now our Bridge Maintenance forces are going to handle the replacement. Our Bridge
Maintenance Engineer has found that switching to a 20’-6” span x 7’-3” rise Aluminum Box Culvert will be more
economical and quicker to install. He is in discussions with the pipe company to have the pipe fabricated with one foot
baffles on a single side to maintain a low flow channel inside the pipe. Prior to giving him the ok to proceed with the
cost, I wanted to run it by you and see if you had any objections. Page 5 and 6 of the attached quote are shop drawings
of what the pipe will look like. Also attached is a picture of the flooding that damaged the pipe. The last pdf is a copy of
pipe inspection report which has pictures of what the pipe looked like under normal conditions.
This is a time sensitive matter, so please respond as soon as possible. Thanks so much!
For reference the DWR permit number is 2019-0749 and the USACE Action ID is 2019-01013.
Amy Euliss
NCDOT Division 9 Environmental Officer
375 Silas Creek Parkway
Winston Salem, NC 27127
(336) 747-7800
Email correspondence to and from this sender is subject to the N.C. Public Records Law and may be disclosed to third parties.
2